Patton 1314, CopperLink 1314 User Manual

For Quick
Start Installation
CopperLink Model 1314
Long Range Ethernet Extender
User Manual
Important
This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in an industrial or residential environment.
REGULATORY MODEL NUMBER: 03340D4-001
Sales Office: +1 (301) 975-1000
Technical Support: +1 (301) 975-1007
E-mail: support@patton.com
WWW: www.patton.com
Part Number: 07MCL1314, Rev. C
Patton Electronics Company, Inc.
7622 Rickenbacker Drive
Gaithersburg, MD 20879 USA
Tel: +1 (301) 975-1000 Fax: +1 (301) 869-9293
Support: +1 (301) 975-1007
Web: www.patton.com
E-mail: support@patton.com
Trademark Statement
The term CopperLink is a trademark of Patton Electronics Company. All other trade­marks presented in this document are the property of their respective owners.
Copyright © 2012, Patton Electronics Company. All rights reserved.
The information in this document is subject to change without notice. Patton Elec­tronics assumes no liability for errors that may appear in this document.
Warranty Information
Patton Electronics warrants all Model CL1314 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the follow­ing: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.
Note
Conformity documents of all Patton products can be viewed online at www.patton.com under the appropriate product page.
Summary Table of Contents
1 General information...................................................................................................................................... 13
2 Configuration................................................................................................................................................ 16
3 CopperLink installation ................................................................................................................................24
4 Operation...................................................................................................................................................... 27
5 Software Upgrade .......................................................................................................................................... 29
6 Contacting Patton for assistance ................................................................................................................... 31
A Compliance information .............................................................................................................................. 34
B Specifications ................................................................................................................................................ 36
C Factory replacement parts and accessories .................................................................................................... 40
D Interface pinouts .......................................................................................................................................... 42
3
Table of Contents
Summary Table of Contents ........................................................................................................................... 3
Table of Contents ........................................................................................................................................... 4
List of Figures ................................................................................................................................................. 7
List of Tables .................................................................................................................................................. 8
About this guide ............................................................................................................................................. 9
Audience................................................................................................................................................................. 9
Structure................................................................................................................................................................. 9
Precautions........................................................................................................................................................... 10
Safety when working with electricity ...............................................................................................................11
General observations .......................................................................................................................................12
Typographical conventions used in this document................................................................................................ 12
General conventions .......................................................................................................................................12
1 General information...................................................................................................................................... 13
CopperLink Model 1314 overview ........................................................................................................................14
Features.................................................................................................................................................................14
Power input connector ..........................................................................................................................................15
External AC universal power supply ................................................................................................................15
External 48 VDC power supply ......................................................................................................................15
2 Configuration................................................................................................................................................ 16
Introduction..........................................................................................................................................................17
Hardware (DIP-switch) configuration .............................................................................................................17
Configuring the DIP switches .........................................................................................................................17
DIP switch settings .........................................................................................................................................18
DIP switch settings: Data Rate ........................................................................................................................19
Ethernet Management Port .............................................................................................................................22
CopperLink Status Command ..................................................................................................................22
Help Commands .......................................................................................................................................22
Example Command Line Interface Session ................................................................................................23
3 CopperLink installation ................................................................................................................................24
Installation ............................................................................................................................................................25
Connecting the CopperLink interface .............................................................................................................25
Connecting the Ethernet interface ..................................................................................................................26
Connecting power ...........................................................................................................................................26
External AC universal power supply ..........................................................................................................26
DC Power .................................................................................................................................................26
4 Operation...................................................................................................................................................... 27
Introduction..........................................................................................................................................................28
Power-up ........................................................................................................................................................28
LED status monitors .......................................................................................................................................28
4
CopperLink Model 1314 User Manual Table of Contents
Power (Green) ...........................................................................................................................................28
Link (Green) .............................................................................................................................................28
ETH Activity (Green) ...............................................................................................................................28
ETH Link (Green) ....................................................................................................................................28
5 Software Upgrade .......................................................................................................................................... 29
Introduction..........................................................................................................................................................30
6 Contacting Patton for assistance ................................................................................................................... 31
Introduction..........................................................................................................................................................32
Contact information..............................................................................................................................................32
Patton support headquarters in the USA .........................................................................................................32
Alternate Patton support for Europe, Middle East, and Africa (EMEA) ..........................................................32
Warranty Service and Returned Merchandise Authorizations (RMAs)...................................................................32
Warranty coverage ..........................................................................................................................................32
Out-of-warranty service .............................................................................................................................33
Returns for credit ......................................................................................................................................33
Return for credit policy .............................................................................................................................33
RMA numbers ................................................................................................................................................33
Shipping instructions ................................................................................................................................33
A Compliance information .............................................................................................................................. 34
Compliance ...........................................................................................................................................................35
EMC ...............................................................................................................................................................35
Safety ..............................................................................................................................................................35
Radio and TV Interference (FCC Part 15) ............................................................................................................35
CE Declaration of Conformity..............................................................................................................................35
Authorized European Representative.....................................................................................................................35
B Specifications ................................................................................................................................................ 36
Line rate ................................................................................................................................................................37
Ethernet interface..................................................................................................................................................37
Status LEDs...........................................................................................................................................................37
Power (Green) ...........................................................................................................................................37
Link (Green) .............................................................................................................................................37
ETH Activity (Green) ...............................................................................................................................37
ETH Link (Green) ....................................................................................................................................37
Configuration........................................................................................................................................................37
Power and power supply specifications
..................................................................................................................38
External AC universal power supply ................................................................................................................38
External 48 VDC power supply ......................................................................................................................38
Transmission line ..................................................................................................................................................39
Line coding ...........................................................................................................................................................39
Line interface.........................................................................................................................................................39
CopperLink physical connection ...........................................................................................................................39
Environment .........................................................................................................................................................39
5
CopperLink Model 1314 User Manual Table of Contents
Third party software licenses..................................................................................................................................39
C Factory replacement parts and accessories .................................................................................................... 40
Factory replacement parts and accessories..............................................................................................................41
D Interface pinouts .......................................................................................................................................... 42
Line port ...............................................................................................................................................................43
Ethernet port.........................................................................................................................................................43
6
List of Figures
1 CopperLink Model 1314 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2 Power connection barrel receptacle 5 VDC diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3 Underside of CL1314 showing location of DIP switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4 CL1314 rear panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5 DC Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
6 CL1314 front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
7 Power connection barrel receptacle 5 VDC diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
7
List of Tables
1 General conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2 CopperLink configurable parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3 S4-2 through S4-8 Data Rate DIP switch settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4 RJ45 socket 10/100Base-T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
8
About this guide
This guide describes installing and operating the Patton Electronics CopperLink™ Model 1314 Long Range Ethernet Extender.
Audience
This guide is intended for the following users:
Operators
Installers
Maintenance technicians
Structure
This guide contains the following chapters and appendices:
Chapter 1 on page 13 provides information about CL1314 features and capabilities
Chapter 2 on page 16 provides information for configuring the CL1314
Chapter 3 on page 24 describes how to install the CL1314
Chapter 4 on page 27 describes how to operate the CL1314
Chapter 5 on page 29 describes how to upgrade the system software
Chapter 6 on page 31 contains information on contacting Patton technical support for assistance
Appendix A on page 34 contains compliance information for the CL1314
Appendix B on page 36 contains specifications for the CL1314
Appendix C on page 40 provides cable recommendations
Appendix D on page 42 describes the CL1314’s ports and pin-outs
For best results, read the contents of this guide before you install the CL1314.
9
CopperLink Model 1314 User Manual
Precautions
Notes, cautions, and warnings, which have the following meanings, are used throughout this guide to help you become aware of potential problems. Warnings are intended to prevent safety hazards that could result in per­sonal injury. Cautions are intended to prevent situations that could result in property damage or impaired functioning.
Note
WARNING
WARNING
CAUTION
CAUTION
A note presents additional information or interesting sidelights.
The shock hazard symbol and WARNING heading indicate a potential electric shock hazard. Strictly follow the warning instructions to avoid injury caused by electric shock.
The alert symbol and WARNING heading indicate a potential safety hazard. Strictly follow the warning instructions to avoid personal injury.
The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard. Strictly follow the instructions to avoid property damage caused by electric shock.
The alert symbol and CAUTION heading indicate a potential haz­ard. Strictly follow the instructions to avoid property damage.
10
CopperLink Model 1314 User Manual
Safety when working with electricity
Do not open the device when the power cord is connected. For systems without a power switch and without an external power adapter, line volt-
WARNING
ages are present within the device when the power cord is connected.
For devices with an external power adapter, the power adapter shall be a listed imited Power Source The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker in compliance with local reg­ulatory requirements.
For AC powered devices, ensure that the power cable used meets all appli­cable standards for the country in which it is to be installed.
For AC powered devices which have 3 conductor power plugs (L1, L2 & GND or Hot, Neutral & Safety/Protective Ground), the wall outlet (or socket) must have an earth ground.
For DC powered devices, ensure that the interconnecting cables are rated for proper voltage, current, anticipated temperature, flammability, and mechanical serviceability.
WAN, LAN & PSTN ports (connections) may have hazardous voltages present regardless of whether the device is powered ON or OFF. PSTN relates to interfaces such as telephone lines, FXS, FXO, DSL, xDSL, T1, E1, ISDN, Voice, etc. These are known as “hazardous network voltages” and to avoid electric shock use caution when working near these ports. When disconnecting cables for these ports, detach the far end connection first.
Do not work on the device or connect or disconnect cables during periods of lightning activity.
WARNING
WARNING
This device contains no user serviceable parts. This device can only be repaired by qualified service personnel.
This device is NOT intended nor approved for connection to the PSTN. It is intended only for connection to customer premise equipment.
In accordance with the requirements of council directive 2002/ 96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.
11
CopperLink Model 1314 User Manual
Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent
CAUTION
failures. Do the following to prevent ESD:
Always follow ESD prevention procedures when removing and replacing cards.
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground.
To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis.
General observations
Clean the case with a soft slightly moist anti-static cloth
Place the unit on a flat surface and ensure free air circulation
Avoid exposing the unit to direct sunlight and other heat sources
Protect the unit from moisture, vapors, and corrosive liquids
Typographical conventions used in this document
This section describes the typographical conventions and terms used in this guide.
General conventions
The procedures described in this manual use the following text conventions:
Table 1. General conventions
Convention Meaning
Garamond blue type
Futura bold type Commands and keywords are in boldface font.
Futura bold-italic type Parts of commands, which are related to elements already named by the user, are
Italicized Futura type Variables for which you supply values are in italic font Futura type Indicates the names of fields or windows. Garamond bold type Indicates the names of command buttons that execute an action.
Indicates a cross-reference hyperlink that points to a figure, graphic, table, or sec­tion heading. Clicking on the hyperlink jumps you to the reference. When you have finished reviewing the reference, click on the Go to Previous View
button in the Adobe® Acrobat® Reader toolbar to return to your starting point.
in boldface italic font.
12
Chapter 1 General information
Chapter contents
CopperLink Model 1314 overview ........................................................................................................................14
Features.................................................................................................................................................................14
Power input connector ..........................................................................................................................................15
External AC universal power supply ................................................................................................................15
External 48 VDC power supply ......................................................................................................................15
13
CopperLink Model 1314 User Manual 1 • General information
CopperLink Model 1314 overview
The CL1314 CopperLink Ethernet Extenders are easy to use and take advantage of existing copper twisted-pair infra­structure to 5.7 twisted pair. Whether enabled devices such as PCs, and distance in the industry.
to connect Ethernet networks or devices at high speeds over long distances. The CL1314 connects at speeds up
Mbps with distances ranging from 3.4 to 5.4 km (2.0 to 3.4 miles) on standard 0.5 mm (24 AWG) voice-grade
setting up a private network backbone to a corporate LANs or remote office or connecting network
digital sensors or IP cameras, Patton Ethernet Extenders offer the best combination of speed
Figure 1. CopperLink Model 1314
Features
High speed extension with speeds up to 5.7 Mbps
2-wire CopperLink connection via built-in RJ-11 port
4 auto 10- or 100Base-T and full or half-duplex Ethernet ports for direct connection of four Ethernet
devices
Extends Ethernet up to 3.4 miles (5.48 km) using 24 AWG/0.5mm wire (192 kbps speed)
CopperLink Model 1314 overview 14
CopperLink Model 1314 User Manual 1 • General information
Power input connector
The CopperLink comes with an AC or DC power supply. (See section “Power and power supply specifica-
tions” on page 38.)
The power connection to the CL1314 is a 2.5 mm barrel receptacle with the center conductor positive
(see figure 2).
Rated voltage: 5 VDC
Rated current: 1
External AC universal power supply
For additional specifications, see section “Power and power supply specifications” on page 38.
Output from power supply: 5 VDC, 2 A
Input to power supply: universal input 100–240 VAC 50/60 Hz 0.3A
A
5 VDC
Figure 2. Power connection barrel receptacle 5 VDC diagram
The external AC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator. Ensure that the AC power
CAUTION
cable meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground.
External 48 VDC power supply
The external DC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator. The interconnecting cables
CAUTION
shall be rated for the proper voltage, current, anticipated tem­perature, flammability, and mechanical serviceability
Refer to section “Power and power supply specifications” on page 38 for additional specifications.
Input
- Rated voltage: 36–60 VDC
- Rated current: 0.25 A DC
- 3-pin locking connector, 3.5 mm pitch
- Transient over-voltage protection, 100VDC at 2 ms
Output
- Rated voltage: 5 VDC ± 5%, 5W
- Rated current; 1 A DC
- 6-inch cable terminated with 2.5 mm barrel plug, center positive
Power input connector 15
Chapter 2 Configuration
Chapter contents
Introduction..........................................................................................................................................................17
Hardware (DIP-switch) configuration .............................................................................................................17
Configuring the DIP switches .........................................................................................................................17
DIP switch settings .........................................................................................................................................18
DIP switch settings: Data Rate ........................................................................................................................19
Ethernet Management Port .............................................................................................................................22
CopperLink Status Command ..................................................................................................................22
Help Commands .......................................................................................................................................22
Example Command Line Interface Session ................................................................................................23
16
CopperLink Model 1314 User Manual 2 • Configuration
Introduction
You can configure the CopperLink through the hardware configuration via DIP switches.
Hardware (DIP-switch) configuration
To use DIP-switch configuration you must first set the DIP switches to a position other than all OFF or all ON before powering-up the CopperLink. When all the DIP switches are set to any position other than all OFF or
all ON the CopperLink will operate in hardware (DIP-switch)-configuration mode. In DIP-switch-configura­tion mode the CopperLink will read the DIP-switch settings during system startup and configure itself accord­ing to the switch settings. Once you power-up the CopperLink in DIP-switch mode, it will operate in DIP­switch mode until powered down. When operating in DIP-switch mode, you cannot change any configuration settings. Table 2 lists the CL1314’s configurable parameters.
Table 2. CopperLink configurable parameters
Parameter Description Possible Values
CopperLink Data Rate/Timeslots
Defines the number of timeslots. The data rate is calculated by the equation: data rate = timeslots x 64k.
1–72 timeslots
Configuring the DIP switches
The CL1314 is equipped with three sets of DIP switches, which you can use to configure the CopperLink for a broad range of applications. This section describes switch locations and discusses the configuration options available.
Note
By default, the CopperLink’s DIP switches are all set to “OFF”. The default configuration for the CopperLink is 89 timeslots (5695 kbps).
The three sets of DIP switches are externally accessible from the underside of the CL1314 (see figure 3).
Introduction 17
CopperLink Model 1314 User Manual 2 • Configuration
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Model CL1314
Figure 3. Underside of CL1314 showing location of DIP switches
The three sets of DIP switches on the underside of the CL1314 are referred to as S1, S3 and S4. For basic configuration, use DIP switch S1. For testing the CL1314, use DIP switch S3. To configure the rate, use DIP switch S4. This figure shows the DIP switch orientation with respect to ON and OFF positions is consistent for all switches.
S4
S3
S1
1 2 3 4 5 6 7 8
ON
ON
DIP switch settings
You can configure the CL1314 by setting the DIP switches to the desired positions before you power up the CopperLink. If the DIP switches are set to anything other than all OFF or all ON, the CopperLink will operate in DIP switch configuration mode. Once the device is powered up and operating in DIP switch configuration mode, you cannot change configuration by any method until you power it down again.
OFF
Introduction 18
CopperLink Model 1314 User Manual 2 • Configuration
DIP switch settings: Data Rate
Switches S4-2 through S4-8 define the CopperLink line rate.
Table 3. S4-2 through S4-8 Data Rate DIP switch settings
S4-2 S4-3 S4-4 S4-5 S4-6 S4-7 S4-8 Data Rate (kbps)
OFF OFF OFF OFF OFF OFF ON 192 OFF OFF OFF OFF OFF ON OFF 256 OFF OFF OFF OFF OFF ON ON 320 OFF OFF OFF OFF ON OFF OFF 384 OFF OFF OFF OFF ON OFF ON 448 OFF OFF OFF OFF ON ON OFF 512 OFF OFF OFF OFF ON ON ON 576 OFF OFF OFF ON OFF OFF OFF 640 OFF OFF OFF ON OFF OFF ON 704 OFF OFF OFF ON OFF ON OFF 768 OFF OFF OFF ON OFF ON ON 832 OFF OFF OFF ON ON OFF OFF 896 OFF OFF OFF ON ON OFF ON 960 OFF OFF OFF ON ON ON OFF 1024 OFF OFF OFF ON ON ON ON 1088 OFF OFF ON OFF OFF OFF OFF 1152 OFF OFF ON OFF OFF OFF ON 1216 OFF OFF ON OFF OFF ON OFF 1280 OFF OFF ON OFF OFF ON ON 1344 OFF OFF ON OFF ON OFF OFF 1408 OFF OFF ON OFF ON OFF ON 1472 OFF OFF ON OFF ON ON OFF 1536 OFF OFF ON OFF ON ON ON 1600 OFF OFF ON ON OFF OFF OFF 1664 OFF OFF ON ON OFF OFF ON 1728 OFF OFF ON ON OFF ON OFF 1792 OFF OFF ON ON OFF ON ON 1856 OFF OFF ON ON ON OFF OFF 1920 OFF OFF ON ON ON OFF ON 1984 OFF OFF ON ON ON ON OFF 2048 OFF OFF ON ON ON ON ON 2112 OFF ON OFF OFF OFF OFF OFF 2176 OFF ON OFF OFF OFF OFF ON 2240 OFF ON OFF OFF OFF ON OFF 2304 OFF ON OFF OFF OFF ON ON 2368 OFF ON OFF OFF ON OFF OFF 2432
Introduction 19
CopperLink Model 1314 User Manual 2 • Configuration
Table 3. S4-2 through S4-8 Data Rate DIP switch settings (Continued)
S4-2 S4-3 S4-4 S4-5 S4-6 S4-7 S4-8 Data Rate (kbps)
OFF ON OFF OFF ON OFF ON 2496 OFF ON OFF OFF ON ON OFF 2560 OFF ON OFF OFF ON ON ON 2624 OFF ON OFF ON OFF OFF OFF 2688 OFF ON OFF ON OFF OFF ON 2752 OFF ON OFF ON OFF ON OFF 2816 OFF ON OFF ON OFF ON ON 2880 OFF ON OFF ON ON OFF OFF 2944 OFF ON OFF ON ON OFF ON 3008 OFF ON OFF ON ON ON OFF 3072 OFF ON OFF ON ON ON ON 3136 OFF ON ON OFF OFF OFF OFF 3200 OFF ON ON OFF OFF OFF ON 3264 OFF ON ON OFF OFF ON OFF 3328 OFF ON ON OFF OFF ON ON 3392 OFF ON ON OFF ON OFF OFF 3456 OFF ON ON OFF ON OFF ON 3520 OFF ON ON OFF ON ON OFF 3584 OFF ON ON OFF ON ON ON 3648 OFF ON ON ON OFF OFF OFF 3712 OFF ON ON ON OFF OFF ON 3776 OFF ON ON ON OFF ON OFF 3840 OFF ON ON ON OFF ON ON 3904 OFF ON ON ON ON OFF OFF 3968 OFF ON ON ON ON OFF ON 4032 OFF ON ON ON ON ON OFF 4096 OFF ON ON ON ON ON ON 4160 ON OFF OFF OFF OFF OFF OFF 4224 ON OFF OFF OFF OFF OFF ON 4288 ON OFF OFF OFF OFF ON OFF 4352 ON OFF OFF OFF OFF ON ON 4416 ON OFF OFF OFF ON OFF OFF 4480 ON OFF OFF OFF ON OFF ON 4544 ON OFF OFF OFF ON ON OFF 4608 ON OFF OFF OFF ON ON ON 4672 ON OFF OFF ON OFF OFF OFF 4736 ON OFF OFF ON OFF OFF ON 4800 ON OFF OFF ON OFF ON OFF 4864
Introduction 20
CopperLink Model 1314 User Manual 2 • Configuration
Table 3. S4-2 through S4-8 Data Rate DIP switch settings (Continued)
S4-2 S4-3 S4-4 S4-5 S4-6 S4-7 S4-8 Data Rate (kbps)
ON OFF OFF ON OFF ON ON 4928 ON OFF OFF ON ON OFF OFF 4992 ON OFF OFF ON ON OFF ON 5056 ON OFF OFF ON ON ON OFF 5120 ON OFF OFF ON ON ON ON 5184 ON OFF ON OFF OFF OFF OFF 5248 ON OFF ON OFF OFF OFF ON 5312 ON OFF ON OFF OFF ON OFF 5376 ON OFF ON OFF OFF ON ON 5440 ON OFF ON OFF ON OFF OFF 5504 ON OFF ON OFF ON OFF ON 5568 ON OFF ON OFF ON ON OFF 5632 ON OFF ON OFF ON ON ON 5696
Introduction 21
CopperLink Model 1314 User Manual 2 • Configuration
Ethernet Management Port
The CL1314 offers a 10/100 Ethernet port to view the current DIP switch settings via Telnet sessions. The Ethernet interface default IP address is 192.168.200.1. Log into the CL1314 management port using the pass­word superuser.
Through the Ethernet management port, the following variables can be configured or monitored:
status: Shows the general configuration and status of the unit
info: Shows system information
upgrade: Enables the system upgrade prompt
CopperLink Status Command
The status command shows the following CopperLink line status information: sync state, link state, link speed, error counters, line condition, noise margin, and test mode status.
The following status information is available through the Command Line Interface:
sync state: Out of Sync, Acquiring Sync, In Sync, or Losing Sync
link state: In Progress, Success, Deactivated, or Idle
Note
Link State vs. Sync State—The Link State describes whether the Copper­Link line is training (in progress), linked (success), deactivated (we don’t have an option to deactivate the modem, so the user should not see this), or idle.
The Sync State describes whether no sync words have been found (out of sync), there are no sync word errors (in sync), or whether we are transition­ing from out of sync to in sync (acquiring sync) or vice versa (losing sync). Typically, when the link is training, the sync state goes from out of sync to acquiring sync to in sync.
actual rate: The actual rate at which the link is running (minus overhead).
noise margin: The maximum tolerable increase in external noise power that still allows for BER of less than
7
1x 10–
.
error counters: The following error counters are available: CRC and LOSW (Loss of Sync Word)
Help Commands
The following commands are provided to help the user find the correct command:
help: Lists all the commands that the console recognizes.
Introduction 22
CopperLink Model 1314 User Manual 2 • Configuration
Example Command Line Interface Session
CL1314 Command Shell Password: CL1314> status configuration: copperlink mode: local copperlink rate: 5696 line probe: disabled status: actual rate: 0 loss of signal: unavailable noise margin: 0 snr: 0 sync state: out of sync link state: idle error counters: crc: 0 losw: 0 CL1314> exit
Note
The line probe feature is a future product enhancement.
Introduction 23
Chapter 3 CopperLink installation
Chapter contents
Installation ............................................................................................................................................................25
Connecting the CopperLink interface .............................................................................................................25
Connecting the Ethernet interface ..................................................................................................................26
Connecting power ...........................................................................................................................................26
External AC universal power supply ..........................................................................................................26
DC Power .................................................................................................................................................26
24
CopperLink Model 1314 User Manual 3 • CopperLink installation
Installation
Once the CL1314 is properly configured, it is ready to connect to the CopperLink interface and to the power source. This section explains how to make these connections.
\
E
IN
L
th3
E
th2
E
th1
E
th0
E
(CopperLink Multi-Port Ethernet Extender)
Model CL1314
Reset
ETH 0
ETH 1 ETH 2 ETH 3
LINE
Figure 4. CL1314 rear panel
Connecting the CopperLink interface
The CL1314 supports communication between two DTE devices as follows:
Using 24 AWG (0.5 mm) wire up to:
18,000 feet (5.48 km) at 192 kbps
11,000 feet (3.5 km) at 5696 kbps
Two things are essential:
1. These units work in pairs. Both units at the end of the twisted pair link span must be set for the same DTE
rate—one unit set as Local (L), the other as Remote (R).
2. To function properly, the CL1314 needs one twisted pair of metallic wire. This twisted pair must be
unconditioned, dry, metallic wire, between 19 (0.9mm) and 26 AWG (0.4mm) (the higher number gauges will limit distance). Standard dial-up telephone circuits, or leased circuits that run through signal equalization equipment, or standard, flat modular telephone type cable, are not acceptable.
The RJ-45 CopperLink connector on the CL1314’s twisted pair interface is polarity insensitive and is wired for a two-wire interface.
Installation 25
CopperLink Model 1314 User Manual 3 • CopperLink installation
Connecting the Ethernet interface
This section describes how to connect the Ethernet ports to your network equipment.
The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt­age, current, anticipated temperature, flammability, and
CAUTION
mechanical serviceability.
The RJ-45 ports labeled Ethernet are the Auto-MDIX10/100Base-T interface. These ports are designed to connect directly to a 10/100Base-T device or network. You may connect these ports to a hub or PC using a straight through or crossover cable that is up to 328 ft long.
Connecting power
External AC universal power supply
1. Connect the power cord from the AC socket to the IEC-320 power entry connector on the universal input
power supply.
The external AC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator. Ensure that the AC power
CAUTION
cable meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground.
2. Connect the barrel plug to the Power connector on the CL1314.
Note
The CL1314 powers up as soon as it is plugged into an AC outlet—there is no power switch.
DC Power
The 36-60 VDC DC to DC adapter is supplied with the DC version of the CL1314. The black and red leads plug into a DC source (nominal 48VDC) and the barrel power connector plugs into the barrel power supply jack on the CL1314. (See Figure 5).
WARNING
To Power
Supply Jack
S/N: G01234567890
MADE IN CHINA BY SUNNY
Barrel power connector
Figure 5. DC Power Supply
There are no user-servicable parts in the power supply section of the CL1314. Fuse replacement should only be performed by qualified service personnel. See Chapter 6,
for assistance”
on page 31.
MODEL : SYD1106-0505
INPUT : 36-60V 0.2A MAX
OUTPUT : +5V 1.0A
OUTPUT POWER : 5W MAX
SWITCHING POWER SUPPLY
-Vin
+Vin
To -48VDC
Source
Black lead (-V)
Red lead (+V)
“Contacting Patton
Installation 26
Chapter 4 Operation
Chapter contents
Introduction..........................................................................................................................................................28
Power-up ........................................................................................................................................................28
LED status monitors .......................................................................................................................................28
Power (Green) ...........................................................................................................................................28
Link (Green) .............................................................................................................................................28
ETH Activity (Green) ...............................................................................................................................28
ETH Link (Green) ....................................................................................................................................28
27
CopperLink Model 1314 User Manual 4 • Operation
Introduction
Once the CL1314 is properly configured and installed, it should operate transparently. The following sections describe power-up, reading the LED status monitors, and using the built-in loopback test modes.
Power-up
To apply power to the CL1314, first be sure that you have read section “Power input connector” on page 15, and that the unit is connected to the appropriate power source. Power up the unit.
LED status monitors
There are ten LEDs that provide feedback on the state of the unit. Figure 6 shows the location of the front panel LEDs. Following figure 6 is a description of each LED’s function.
Ethernet Ports
Line Link
Powe r
Figure 6. CL1314 front panel
Power (Green)
The Power LED glows solid during normal operation. At startup, during the POST, the LED blinks once every second. If the POST fails, the unit does not enter normal operation, and the LED blinks once every
0.4 seconds.
Link (Green)
The Link LED glows solid while a link is established. While the link is training, it blinks once every second.
ETH Activity (Green)
The Ethernet Activity LED shows that there is data being transferred via that Ethernet port. During a software upgrade procedure, if the Activity LED is on for an unusually long time, there is a problem with the upgrade, and the device should be restarted. The TFTP server should be checked (normal upgrades take about 10 sec­onds on a 100mbit link).
ETH Link (Green)
The Ethernet Link LED shows that there is an active physical connection to the console, or an active physical connection to an Ethernet device.
Introduction 28
Chapter 5 Software Upgrade
Chapter contents
Introduction..........................................................................................................................................................30
29
CopperLink Model 1314 User Manual 5 • Software Upgrade
Introduction
The software upgrade feature is available through BOOTP/TFTP. The software upgrade takes approximately 2-3 minutes to complete. To upgrade the software:
1. Connect to the CL1314 via the Ethernet management port and a Telnet session.
2. Enter the info command to view the unit’s MAC address.
3. Configure a BOOTP/TFTP server and enter the upgrade / yes command to begin the upgrade.
4. Alternatively, you may enter the upgrade <TFTP server IP address>:/<filename> command to begin the
upgrade.
After approximately 2-3 minutes, the CL1314 will operate with the upgraded software.
Introduction 30
Chapter 6 Contacting Patton for assistance
Chapter contents
Introduction..........................................................................................................................................................32
Contact information..............................................................................................................................................32
Patton support headquarters in the USA .........................................................................................................32
Alternate Patton support for Europe, Middle East, and Africa (EMEA) ..........................................................32
Warranty Service and Returned Merchandise Authorizations (RMAs)...................................................................32
Warranty coverage ..........................................................................................................................................32
Out-of-warranty service .............................................................................................................................33
Returns for credit ......................................................................................................................................33
Return for credit policy .............................................................................................................................33
RMA numbers ................................................................................................................................................33
Shipping instructions ................................................................................................................................33
31
CopperLink Model 1314 User Manual 6 • Contacting Patton for assistance
Introduction
This chapter contains the following information:
“Contact information”—describes how to contact Patton technical support for assistance.
“Warranty Service and Returned Merchandise Authorizations (RMAs)”—contains information about the
warranty and obtaining a return merchandise authorization (RMA).
Contact information
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.
Patton support headquarters in the USA
Online support: available at www.patton.com
E-mail support: e-mail sent to support@patton.com will be answered within 1 business day
Telephone support: standard telephone support is available five days a week—from 8:00 am to
5:00 pm EST (1300 to 2200 UTC/GMT)—by calling +1 (301) 975-1007
Fax: +1 (253) 663-5693
Alternate Patton support for Europe, Middle East, and Africa (EMEA)
Online support: available at www.patton-inalp.com
E-mail support: e-mail sent to support@patton-inalp.com will be answered within 1 business day
Telephone support: standard telephone support is available five days a week—from 8:00 am to
5:00 pm CET (0900 to 1800 UTC/GMT)—by calling +41 (0)31 985 25 55
Fax: +41 (0)31 985 25 26
Warranty Service and Returned Merchandise Authorizations (RMAs)
Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship­ment. All of our products are backed by a comprehensive warranty program.
Note
Warranty coverage
Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod­uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work­manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.
If you purchased your equipment from a Patton Electronics reseller, ask your reseller how you should proceed with warranty service. It is often more con­venient for you to work with your local reseller to obtain a replacement. Patton services our products no matter how you acquired them.
Introduction 32
CopperLink Model 1314 User Manual 6 • Contacting Patton for assistance
Out-of-warranty service
Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastro­phes may require replacement.
Returns for credit
Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.
Return for credit policy
Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.
30 to 60 days: We will add a 20% restocking charge (crediting your account with 80% of the purchase price).
Over 60 days: Products will be accepted for repairs only.
RMA numbers
RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:
Completing a request on the RMA Request page in the Support section at www.patton.com
By calling +1 (301) 975-1007 and speaking to a Technical Support Engineer
By sending an e-mail to returns@patton.com
All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.
Shipping instructions
The RMA number should be clearly visible on the address label. Our shipping address is as follows:
Patton Electronics Company
RMA#: xxxx 7622 Rickenbacker Dr. Gaithersburg, MD 20879-4773 USA
Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.
Warranty Service and Returned Merchandise Authorizations (RMAs) 33
Appendix A Compliance information
Chapter contents
Compliance ...........................................................................................................................................................35
EMC ...............................................................................................................................................................35
Safety ..............................................................................................................................................................35
Radio and TV Interference (FCC Part 15) ............................................................................................................35
CE Declaration of Conformity..............................................................................................................................35
Authorized European Representative.....................................................................................................................35
34
CopperLink Model 1314 User Manual A • Compliance information
Compliance
EMC
FCC Part 15, Class A
EN55022, Class A
EN55024
Safety
UL 60950-1/CSA C22.2 N0. 60950-1
IEC/EN60950-1 2nd edition
AS/NZS 60950-1
Radio and TV Interference (FCC Part 15)
This device generates and uses radio frequency energy, and if not installed and used properly-that is, in strict accordance with the manufacturer’s instructions-may cause interference to radio and television reception. The device has been tested and found to comply with the limits for a Class A computing device in accordance with specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the device does cause interference to radio or television reception, which can be determined by disconnecting the unit, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equip­ment and receiver are on different branches).
CE Declaration of Conformity
Patton Electronics, Inc declares that this device is in compliance with the essential requirements and other rel­evant provisions of Directive 1999/5/EC. The Declaration of Conformity may be obtained from Patton Elec­tronics, Inc at www.patton.com/certifications
The safety advice in the documentation accompanying this device shall be obeyed. The conformity to the above directive is indicated by CE mark on the device.
.
Authorized European Representative
D R M Green
European Compliance Services Limited.
Avalon House, Marcham Road
Abingdon,
Oxon OX14 1UD, UK
Compliance 35
Appendix B Specifications
Chapter contents
Line rate ................................................................................................................................................................37
Ethernet interface..................................................................................................................................................37
Status LEDs...........................................................................................................................................................37
Power (Green) ...........................................................................................................................................37
Link (Green) .............................................................................................................................................37
ETH Activity (Green) ...............................................................................................................................37
ETH Link (Green) ....................................................................................................................................37
Configuration........................................................................................................................................................37
Power and power supply specifications ..................................................................................................................38
External AC universal power supply ................................................................................................................38
External 48 VDC power supply ......................................................................................................................38
Transmission line ..................................................................................................................................................39
Line coding ...........................................................................................................................................................39
Line interface.........................................................................................................................................................39
CopperLink physical connection ...........................................................................................................................39
Environment .........................................................................................................................................................39
Third party software licenses..................................................................................................................................39
36
CopperLink Model 1314 User Manual B • Specifications
Line rate
192 to 5696 kbps (64k increments)
Ethernet interface
Four RJ-45, 10/100Base-T, IEEE 802.3 Ethernet
Status LEDs
Power (Green)
The Power LED glows solid during normal operation. At startup, during the POST, the LED blinks once every second. If the POST fails, the unit does not enter normal operation, and the LED blinks once every
0.4 seconds.
Link (Green)
The Link LED glows solid while a link is established. While the link is training it blinks once every second.
ETH Activity (Green)
The Ethernet Activity LED shows that there is data being transferred over that port. During a software upgrade procedure, if the Activity LED is on for an unusually long time, there is a problem with the upgrade, and the device should be restarted. The TFTP server should be checked (normal upgrades take about 10 seconds on a 100mbit link).
ETH Link (Green)
The Ethernet Link LED shows that there is an active physical network connection to the Console or an Ether­net device.
Configuration
Configuration is done with externally accessible DIP switches.
Line rate 37
CopperLink Model 1314 User Manual B • Specifications
Power and power supply specifications
The CL1314 comes with either an AC or DC power supply:
The supply’s connection to the CL1314 is a 2.5 mm barrel receptacle with the center conductor positive.
There is one fuse in the equipment rated at 250V, 500 mA, 2 sec.
Rated voltage: 5 VDC
Rated current: 1 A DC
5 VDC
Figure 7. Power connection barrel receptacle 5 VDC diagram
External AC universal power supply
The external AC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator. Ensure that the AC power
CAUTION
cable meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground.
Output from power supply: 5 VDC, 2A
Input to power supply: universal input 100–240 VAC 50/60 Hz 0.3A
External 48 VDC power supply
The external DC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator. The interconnecting cables
CAUTION
shall be rated for the proper voltage, current, anticipated tem­perature, flammability, and mechanical serviceability
Input
- Rated voltage: 36–60 VDC
- Rated current: 0.25 A DC
Output
- Rated voltage: 5 VDC ± 5%, 5W
- Rated current: 1 A DC
- 6-inch cable terminated with 2.5 mm barrel plug, center positive
Isolation: 500 VDC
Environment: 0–40°C; 5–95% relative humidity, non-condensing
Power and power supply specifications 38
CopperLink Model 1314 User Manual B • Specifications
Transmission line
Single Twisted Pair
Line coding
TC-PAM (Trellis Coded Pulse Amplitude Modulation)
Line interface
Transformer coupled, 2500 VRMS isolation
CopperLink physical connection
RJ-45, 2-wire polarity insensitive pins 4 and 5
Environment
Operating temp: 32–122°F (0–50°C)
Humidity: 5–95% non-condensing
Altitude: 0–15,000 feet (0–4,600 meters)
Third party software licenses
Note
The CL1314 includes software developed under third party licenses. Con­tact Patton (Chapter 6, “Contacting Patton for assistance” on page 31) for more information.
Transmission line 39
Appendix C Factory replacement parts
and accessories
Chapter contents
Factory replacement parts and accessories..............................................................................................................41
40
CopperLink Model 1314 User Manual C • Factory replacement parts and accessories
Factory replacement parts and accessories
Power Supplies
PS-03671H1-00 100-240VAC (12V, DC/2A) Wall mount power adapter
Power Adapters
12-130 European replacement plug 12-129 American replacement plug 12-131 United Kingdom plug 12-132 Australian/Chinese plug
Factory replacement parts and accessories 41
Appendix D Interface pinouts
Chapter contents
Line port ...............................................................................................................................................................43
Ethernet port.........................................................................................................................................................43
42
CopperLink Model 1314 User Manual D • Interface pinouts
Line port
RJ-45 connector
Pin # Signal
1 No connection 2 No connection 3 No connection 4 Tip 5 Ring 6 No connection 7 No connection 8 No connection
Ethernet port
Note
Table 4. RJ45 socket 10/100Base-T
Pin Signal
1 TX+ 2 TX­3 RX+ 6 RX-
Pins not listed are not used.
Line port 43