Patton 9200, 9100, 9300 User Manual

OnSite Models 9100, 9200, & 9300
Expansion Modules
Quick Start Guide
Part Number: 07M9000-QS, Rev. A Revised: November 20, 2009
Sales Office: +1 (301) 975-1000
Technical Support: +1 (301) 975-1007
E-mail: support@patton.com
WWW: www.patton.com
WARNING
Read the safety information in the OnSite Series and
Administrator’s Reference Guide
operating your OS-10 Series system. Failure to follow this safety infor­mation can lead to personal injury or damage to the equipment.
thoroughly before installing and
Getting Started Guide

1.0 Introduction

This guide provides instructions for adding expansion modules to your Patton OnSite base system. Refer to the following sections for installation instructions for your specific module:
2.0 “Model 9100 E1 Module”
3.0 “Model 9200 Ethernet Module”
4.0 “Model 9300 STM-1 Module”
on page 2
on page 4
on page 5

2.0 Model 9100 E1 Module

2.1 Unpacking and Installation

To install the HD-E1 module, follow the procedures in Chapter 7 of the
Guide
. Figure 1 shows the alignment and insertion of the HD-E1 module into one of the available expansion slots
OnSite Series Administrator’s Reference
of the OS-10.
The High-density E1 module is NOT hot swappable. You will need to power down the OS-10 system before starting the module insertion pro­cedure.
CAUTION
Figure 1.
2
Installing the HD-E1 module
OnSite Expansion Modules Quick Start Guide

2.2 Cable Management

The HD-E1 module uses a future bus connector on the front panel and requires the use of cables with compatible plugs for access to the E1 signals. These cables are ordered separately from the module and need to be specified according to the termination option for the module (75-ohm or 120-ohm) and the required cable length for the site.
Note
Contact your local Patton sales representative if the shipment does not include the required cables for the module.
Chapter 7 of the
OnSite Series Administrator’s Reference Guide
provides information on the location and signal pin-out for each of the 21 E1 ports on the future bus connector. Each module requires six cables for access to all 21 E1 ports. When installing the cables, make sure that the cable bundle does not cause strain on the future bus connector by pulling it up or down or sideways. You may tie the cable bundle together using a strap, as shown in Figure 2, to create a strain relief bend. In addition, use another strap, as shown in Figure 2, to tie the cable bun­dle to the rack post. This additional strap secures the cable bundle in place and prevents accidental movement
that may cause strain to the connector.
Make sure that cable plug has the correct orientation before inserting the plug into the module. The plug should be inserted within a single section of the future bus connector with the release latch facing down. (The mod-
CAUTION
ule has six, 24-pin connector sections.) The plug should snap into place smoothly without the use of force. Wrong insertion may bend the connec­tor pins.
Figure 2.
OnSite Expansion Modules Quick Start Guide
Cable dressing for the HD-E1 module