SPECIFICATIONS
1.0 WARRANTY INFORMATION
Patton Electronics warrants all Model 500/501/502 components to
be free from defects, and will—at our option—repair or replace the
product should it fail within one year from the first date of shipment.
Connectors: DB-25, one male, one female
Pins Wired/Protected: 2, 3, 7 & 20
Surge Capacity: 1.5kW for 1 mS
Response Time: Clamped to + or - 27 volts after 0.5 µS,
400 Amps with a 8/20 µS pulse
Model 501
Connectors: DB-25, one male, one female
Pins Wired/Protected: 2, 3, 4, 5, 6, 7, 8 & 20
Surge Capacity: 1.5kW for 1 mS
Response Time: Clamped to + or - 27 volts after 0.5 µS,
400 Amps with a 8/20 µS pulse
Model 502
Connectors: DB-25, one male, one female
Pins Wired/Protected: 2, 3, 4, 5, 6, 7, 8, 15, 17, 20 & 24
This warranty is limited to defects in workmanship or materials, and
does not cover customer damage, abuse or unauthorized modification.
If this product fails or does not perform as warranted, your sole recourse
shall be repair or replacement as described above. Under no condition
shall Patton Electronics be liable for any damages incurred by the use
of this product. These damages include, but are not limited to, the
following: lost profits, lost savings and incidental or consequential
damages arising from the use of or inability to use this product. Patton
Electronics specifically disclaims all other warranties, expressed or
implied, and the installation or use of this product shall be deemed an
acceptance of these terms by the user.
1.1 SERVICE
All warranty and non-warranty repairs must be returned freight
prepaid and insured to Patton Electronics. All returns must have a
Return Materials Authorization number on the outside of the shipping
container. This number may be obtained from Patton Electronics
Technical Service at (301) 975-1007.
Packages received without an
RMA number will not be accepted.
Patton Electronics' technical staff is also available to answer any
questions that might arise concerning the installation or use of your
Model 500/501/502. Technical Service hours: 8AM to 5PM EST,
Monday through Friday.
Surge Capacity: 1.5kW for 1 mS
Response Time: Clamped to + or - 27 volts after 0.5 µS,
400 Amps with a 8/20 µS pulse
4
1

2.0 GENERAL INFORMATION
3.0 INSTALLATION
Thank you for your purchase of this Patton Electronics product.
This product has been thoroughly inspected and tested and is
warranted for One Year parts and labor. If any questions or problems
arise during installation or use of this product, please do not hesitate to
contact Patton Electronics Customer Service at (301) 975-1007.
2.1 FEATURES
• Can handle large surges caused by storms, power outages, etc.
• Power handling capacity, 1.5 kW at 1.0 mS
• Provides separate connection to chassis ground for surge handling
• Easy to install
2.2 DESCRIPTION
Transient overvoltages can be caused by lightning, coupling from
power line surges and induction from nearby loads such as motors,
factory equipment, etc. Data lines which are run near power, control or
telephone cables are subject to short duration pulses which could reach
several thousand volts. Patton Electronics RS-232 Surge Protectors
use the latest in transient surge suppression technology to guard
against potential damage.
The method of surge protection used in the 500/501/502 adds four
benefits to your system: (1) High Surge Capability
. The 500/501/502
dissipates up to 1.5 kW in 1.0 mS; (2) Quick Response. The
500/501/502 has a response time that is almost instantaneous at
0.5 µs — transient surges are clamped at 27 volts; (3) Low Impedance.
Connect the 500/501/502 directly to RS-232 ports with minimal load to
your system — about the same as a gender changer; (4) Open Failure.
Unlike some other surge suppressors, the 500/501/502 fails "open" if
your system experiences an extreme transient or severe current
overload. Therefore, even if the unit fails, it protects your equipment by
shunting transient surges directly to ground.
Patton's Model 500/501/502 units are easy to install and should
give you years of trouble-free service. Here are a few simple
instructions to help you get things hooked up right:
1. Unplug (disconnect) the existing connection between the RS-232
cable and the equipment’s serial port.
2. Install the Model 500/501/502 between the incoming RS-232 line
and the protected equipment (see below). Place the surge
protector as close as possible to the device being protected.
3. Connect the braided ground strap directly to a frame ground
connection on the protected device. If you are unsure where to
locate a frame ground connection on your equipment, consult the
equipment's user manual or contact the manufacturer—the ground
connection is critical for proper operation of the Model
500/501/502.
Alternate Ground Connections
The Model 500 protects pins 2, 3, 7 and 20 against transient
overvoltages. The Model 501 protects pins 2, 3, 4, 5, 6, 7, 8 and 20.
The Model 502 protects pins 2, 3, 4, 5, 6, 7, 8, 15, 17, 20 and 24. All
three models can be connected directly to your equipment’s RS-232
serial port, and guard against surges up to 1.5 kW.
Warning: This product will not provide complete protection should your
equipment or building be subject to a direct lightening hit.
2
3