Patton 2702 G.703 User Manual

USER MANUAL
MODEL 2702
G.703 Interface Converter
SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com
An ISO-9001
Certified Company
Copyright © 2006
Patton Electronics Company
All Rights Reserved.
CERTIFIED
PATTON MODEL 2702
TABLE OF CONTENTS
Section
Page
1.0 General Information ...............................................................2
1.1 Warranty Statement
1.2 Radio and TV Interference
1.3 CE and Telecommunication Approvals
1.4 Service Information
2.0 General Information ...............................................................6
2.1 Features
2.2 General Product Description
2.3 Supported Applications
2.3.1 The 2702 as the Interface Between the Telco & CPE
2.3.2 The 2702 as the High-Speed Short Range Modem
3.0 Configuration .........................................................................7
3.1 DIP Switch Configuration
4.0 Installation ..........................................................................10
4.1 DTE Interface Connection
4.2 Network Interface Connection
4.3 Power Connection
4.3.1 Using the AC Power Supply (100-240VAC)
4.3.2 Supplying DC Power
4.3.3 Supplying Power via Pin KK
5.0 Operation.............................................................................12
5.1 LED Descriptions
5.2 Loop (V.54 & Telco) Diagnostics
5.2.1 Operating Local Loopback (LL)
5.2.2 Operating Remote Digital Loopback (RL)
Appendix A - Specifications........................................................15
Appendix B - Cable Recommendations .....................................16
Appendix C - Factory Replacement Parts and Accessories.......17
Appendix D - Interface Pin Assignments ....................................18
Appendix E - Power Supply Interface.........................................20
1.0 GENERAL INFORMATION
Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warrant­ed for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to con­tact Patton Electronics Technical Services at (301) 975-1007.
1.1 WARRANTY STATEMENT
Patton Electronics warrants all Model 2702 components to be
free from defects, and will—at our option—repair or replace the prod­uct should it fail within one year from the first date of shipment.This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse, or unauthorized modification. This product contains no serviceable parts; therefore the user shall not attempt to modify the unit in any way. If this product fails or does not perform as warranted, your sole recourse shall be repair or replace­ment as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages aris­ing from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user. In the event the user detects intermittent or continuous product malfunction due to nearby high power transmitting radio frequency equipment, the user is strongly advised to use only data cables with an external outer shield bonded to a metal or metal­ized connector.
1 2
1.2 RADIO AND TV INTERFERENCE
The Model 2702 generates and uses radio frequency energy, and if not installed and used properly-that is, in strict accordance with the manufacturer's instructions-may cause interference to radio and televi­sion reception. The Model 2702 has been tested and found to comply with the limits for a Class Acomputing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commer­cial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 2702 does cause interference to radio or television reception, which can be determined by disconnecting the cables, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).
1.3 CE AND TELECOMMUNICATION APPROVALS
The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). ACertificate of Compliance is available by contacting Technical Support.
The Model 2702 is in compliance with the Telecommunication technical requirements CRT-12; 2.048 Mbps digital unstructured leased line (D2048U) attachment requirements for terminal equipment interface.
3
1.4 SERVICE INFORMATION
All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Support at:
tel: (301) 975-1007;
email: support@patton.com
www: http://www.patton.com.
NOTE: Packages received without an RMA number will not be
accepted.
Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Patton Model 2702. Technical Services hours: 8AM to 5PM EST,
Monday through Friday.
4
2.0 GENERAL INFORMATION
Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warrant­ed for One Year parts and labor. If any questions arise during installa­tion or use of the unit, contact Patton Electronics Technical Services at (301) 975-1007.
2.1 FEATURES
• Converts Synchronous unframed 2 Mbps G.703 to V.35
• Integral V.35 (M/34) Male connector (6 Pin Cisco router also available)
• V.54 Compliant Loopback Diagnostics
• Easy to Read LEDs for TXD, RSD, ALM, LOTC, TST, and ERR
• AMI or HDB3 Line Coding
• Configuration via DIP Switches
• External 100-240VAC Power Supply
2.2 GENERAL PRODUCT DESCRIPTION
The Patton Model 2702 fits into an environment where high-speed E1/G.703 services are being offered to customers with Router/FRADS and other networking devices. These G.703 Interface Converters are required to convert signals from the unstructured, synchronous line interface - delivered by the carrier - to a 2 Mbps digital interface required by the users networking equipment.
To accomplish this, the Model 2702 presents a RJ48C interface to the line and a V.35 interface to the customer’s device. The V.35 inter­face is presented using a Male M/34 connector. Line coding and clock options may be selected using internally accessible DIP Switches
If other interfaces are required, you may select our Model 2703 con­verter which presents the following interfaces: X.21, RS422/530, V.36/RS449 and V.24/RS232. These interfaces are delivered through a standard interface cable which connects to the Female DB25 on one end and the desired interface on the other end. If other DTE speeds are necessary, our Model 2094 connects Fractional E1 at nx64 speeds up to 2 Mbps. Please see the interface converter section of the Patton Catalogue for the required converter.
5
2.3 SUPPORTED APPLICATIONS
The Model 2702 provides a E1 network termination between E1 and customer premises equipment (CPE) such as a router. The Model 2702 can also be used as a high-speed short haul modem for campus applications.
2.3.1 The 2702 as the Interface between the Telco and CPE
The Model 2702 provides the interface between an E1 multiplexer
and a router or switch (See below).
2.3.2 The 2702 as a High-Speed Short Range Modem
The Model 2702 can also be installed into high-speed campus applications. In this application, a pair of Model 2702 units operate as short range modems (See below).
6
Model 2702 Model 2702
Internet
LAN
Model 2702
MUX
DACS
E1/FE1
from
64kbps to
2.042Mbps
Customer Site
Service Provider’s Network
Customer Site
Service Provider’s Network
Loading...
+ 7 hidden pages