Patton 2173R User Manual

USER MANUAL
MODEL 2173R
Ruggedized High Speed Ethernet Extender
An ISO-9001Certified
Company
Part# 07M2173R-UM Rev. A Revised 6/13/11
SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007
CONTENTS
1.0 Warranty Information ................................................................. 4
1.1 Compliance................................................................................... 4
EMC Compliance:......................................................................... 4
Low-Voltage Direcive (Safety):..................................................... 4
PSTN:.................................................. ..... ...... ..... ...... ................... 4
1.2 Radio and TV Interference (FCC Part 15) .................................... 4
1.3 CE Declaration of Conformity ....................................................... 5
1.4 Authorized European Representative........................................... 5
1.5 Service.......................................................................................... 5
1.6 Safety When Working With Electricity .......................................... 6
2.0 General Information.................................................................... 8
2.1 Features........................................................................................ 8
2.2 Description.................................................................................... 8
3.0 Installation................................................................................... 9
3.1 Connecting the Twisted-Pair Line Interface................................ 10
3.2 Connecting the 10/100Base-T Ethernet Interface ...................... 11
3.3 Connecting Power ......................... ............................................. 12
4.0 Configuration ............................................................................ 12
4.1 Configuring the hardware DIP switches..................... ...... ........... 12
4.2 Configuring DIP Switch S1......................................................... 14
5.0 Operation................................................................................... 14
5.1 Power Up.................................................................................... 14
5.2 Front Panel LED Status Monitors ............................................... 15
A
Specifications ........................................................................... 16
A.1 LAN Connection ......................................................................... 16
A.2 Transmission Line ....................................................................... 16
A.3 CopperLINK Line Rate and CopperLINK Distance .................... 16
A.4 LED Status Indicators ................................................................. 16
A.5 Power Supply .............................................................................. 16
A.6 Temperature Range .................................................................... 16
A.7 Humidity ...................................................................................... 16
A.8 Dimensions ................................................................................. 16
B
Model 2173R Factory
Replacement Parts and Accessories ...................................... 17
C
Model 2173R Interface Pin Assignment.................................. 18
C.1 10/100Base-T Interface .............................................................. 18
2
RJ-45.......................................................................................... 18
C.2 CopperLINK Interface ................................................................ 18
RJ-45.......................................................................................... 18
D
Sample Rates/Distance Chart, Based on 24 AWG (0.5 MM) . 19
3

1.0 WARRANTY INFORMATION

Patton Electronics warrants all Model 2173R components to be free from defects, and will—at our opti on —repair or replace the product should it fail within one year from the first date of the shipment.
This warranty is limited to de fects in workmansh ip or material s, and does not cover customer damage, abuse or unauthorized modification. If this product fails or do es not perfo rms as warrante d, you r so le reco urse shal l be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These dama ges include , but are not limite d to, the follow ing: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics spe
­cifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.
Note Conformity documents of all Patton products can be viewed
online at www.patton.com under the appropriate product page.

1.1 COMPLIANCE

EMC Compliance:

• FCC Part 15, Class A
• EN55022, Class A
• EN55024
• A-tick

Low-Voltage Direcive (Safety):

• IEC/EN60950-1, 2nd Edition
• AS/NZS 60950-1, A-tick

PSTN:

• This device is not intended nor approved for connection to the PSTN.

1.2 RADIO AND TV INTER FERENCE (FCC PART 15)

This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manu facturer's instructions—may cause interference to radio and television
4
-
reception. This eq uip me nt h as bee n tested and found to comply with the limits for a Class A computing device in accordance with the specifica
­tions in Subpart B of Part 15 of FCC rules, whic h are designed to prov ide reasonable protection from such interference in a commercial installa
­tion. However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re­orienting the rece iving anten na, and /or plu gging the rec eivi ng equ ipmen t into a different AC outlet (such that the computing equipment and receiver are on different branches).

1.3 CE DECLARATION OF CONFORMITY

We certify that the apparatus described above conforms to the require­ments of Council Directive 2004/108/EC on the approximation of the laws of the member states relating to electromagnetic compatibility; and Council Directive 2006/95/EC on the approximation of the laws of the member states relating to electrical equipment designed for use within certain voltage limits.
The safety advice in the doc um entation accompanying this pro duc t s hall be obeyed. The conformity to the above directive is indicated by the CE sign on the device.

1.4 AUTHORIZED EUROPEAN REPRESENTATIVE

D R M Green, European Compliance Services Limited. Avalon House, Marcham Road, Abingdon, Oxon OX14 1UD, UK

1.5 SERVICE

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electro nic s. All retu rns mus t hav e a Ret urn M ate ri als Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Services at:
•Tel: +1 (301) 975-1007
•Email: support@patton.com
• URL: http://www.patton.com
Note Packages received without an RMA number will not be
accepted.
5
-

1.6 SAFETY WHEN WORKING WITH ELECTRICITY

• This device contains no user serviceable parts. This device can only be repaired by qualified service per sonnel.
• Do not open the device when the power cord is con­nected. For systems without a power switch and without an external power adapter, line voltages are present within the device when the power cord is connected.
• For devices with an external power adapter, the power adapter shall be a listed Limited Power Source. The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker in com pliance with local regulatory requirements.
• For AC powered devices, ensure that the power cable used meets all applicable standards for the country in which it is to be installed.
• For AC powered devices which have 3 conductor power plugs (L1, L2 & GND or Hot, Neutral & Safety/
WARNING
Protective Ground), the wall outlet (or socket) must have an earth ground.
-
-
• For DC powered devices, ensure that the interconnect­ing cables are rated for proper voltage, current, antici­pated temperature, flammability, and mechanical serviceability.
• WAN, LAN & PSTN ports (connections) may have haz­ardous voltages present regardless of whether the device is powered ON or OFF. PSTN relates to inter faces such as telephone lines, FXS, FXO, DSL, xDSL, T1, E1, ISDN, Voice, etc. These are known as “hazard ous network voltages” and to avoid electric shock use caution when working near these ports. When discon necting cables for these ports, detach the far end con­nection first.
• Do not work on the device or connect or disconnect cables during periods of lightning activity.
-
6
-
-
WARNING
WARNING
In accordance with the requirements of council direc­tive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you sepa rate this product from other waste and scrap and deliver to the WEEE collection system in your country for recy cling.
This device is NOT intended nor approved for connec­tion to the PSTN. It is intended only for connection to customer premise equipment.
When the 2173R is mounted, it shall be secured in such a way as to withstand a vertical shear force of 50N or 14 pounds.
Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures. Do the fol lowing to prevent ESD:
-
-
-
WARNING
• Always follow ESD prevention procedures when removing and replacing cards.
• Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely chan nel unwanted ESD voltages to ground.
• To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis.
7
-

2.0 GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for one year for parts and labor. If any questions or problems arise during installation or use of this product, contact Patton Electronics Technical Support at +1 (301) 975-1007.

2.1 FEATURES

• Variable rate CopperLINK extender - Easy to configure
• Auto-MDIX Ethernet
• Configurable 10/100, Full/Half, and Auto-Negotiating Ethernet
• Extends network connections up to 5,500 ft (1.6 km) over 2-wire 24-
AWG unconditioned lines
• Auto-Rate line rates up to 100 Mbps downstream/70 Mbps upstream
• Symmetric or asymmetric settings via DIP switch
• Transparent operation
• LED indicators for Power, Link, Ethernet Link & Activity, and Remote/Local

2.2 DESCRIPTION

The Patton Electronics Model 2173R Ruggedized Ethernet Extender provides high-speed LAN connections between peered Ethernet LANs, remote PCs, or any other network enabled 10/100Base-T device.
Operating in pairs, one Model 2173R or 2173 is configured as the (L) Local unit located at one end of the LAN extension and the other Model 2173R or 2173 is configured as the (R) Remote unit at the other end. These units can automatically forward LAN broadcasts, multicast s, and frames across a 2-wire voice-grade twisted-pair link. The data is pas sed transp a rently (unmodified) through the 2173Rs or 2173s. The 2173Rs automatically add and delete MAC addresses, only passing packets across the CopperLINK link that are meant for the remote peered LAN.
8
Figure 1. Typical application
The pair of 2173R and 2173 models work together to create a transparent extension between two peered Ethernet LANs.
Figure 1 shows a typical
point-to-point application.

3.0 INSTALLATION

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica­tion with respect to voltage, current, anticipated tem-
CAUTION
perature, flammability, and mechanical serviceability.
To install the 2173R Ethernet Extender, do the following:
1. Connect the line interface between the units (refer to section 3.1,
“Connecting the Twisted-Pair Line Interface” on page 10)
Note See Figure 2 for the standalone unit’s rear panel arrangements.
2. Connect the Ethernet interface (refer to section 3.2, “Connec ting the
10/100Base-T Ether net Interface” on page 11).
3. Connect the power plug (refer to section 3.3 , “Conne cting Power” on
page 12).
9
2173R
(RJ-45)
CopperLink 2173R
Ruggedized Ethernet Extender
r e w o
k
P in L
t 1 e rn e
t 2
th
e
E
rn e th
te
E
o m
l
e
a c
R
o
L
t
e
rn
e
th
E
1
2
r
e
A
w
o
.6
P
; 0
V
5
e
in
L
Power
jack
CopperLINK twisted-pair
RJ-45 interface
Ethernet
Ethernet
port 2
port 1
Figure 2. Model 2173R panel

3.1 CONNECTING THE TWISTED-PAIR LINE INTERFACE

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica
-
tion with respect to voltage, current, anticipated tem-
CAUTION
perature, flammability, and mechanical serviceability.
The Model 2173R supports communication between two peer Ethernet LAN sites over a distance of up to 5,500 ft (1.6 km) over 24 AWG (0.5 mm) twisted-pair wire.
Note Actual distance and link performance may vary depending on
the environment and type/gauge of wire used.
Follow the steps below to connect the Model 2173R CopperLINK Inter­faces.
Note The Model 2173R units work in pairs. One of the units must be
configured as a (L) Local unit, and the other unit must be config­ured as a (R) Remote unit. It does not matter which end is the L and which is the R. The link is always initiated by the R unit. As long as the L unit is powered on, the R unit can establish a link by being powered on or by having its power reset.
1. To function properly, the two Model 2173Rs must be connected together using twisted-pair, unconditioned, dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.
10
2. The Model 2173R is equipped with either an RJ-45 interface jack that
) ) )
) ) )
can be used on the CopperLINK interface. These CopperLINK inter
-
faces are a two-wire interface. Observe the signal/pin relationship s on the Model 2173R's CopperLINK interface jacks.
The RJ-45 connector on the Model 2173R's twisted pair interface is polarity insensitive and is wired for a two-wire interface. The signal/pin relationship is shown in Figure 3.
1 (no connection
1 2 3 4 5 6 7 8
2 (no connection 3 (no connection 4 (RING) 5 (TIP) 6 (no connection 7 (no connection 8 (no connection
Figure 3. Model 2173R (RJ-45) twisted pair line interface.

3.2 CONNECTING THE 10/100BASE-T ETHERNET INTERFACE

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica
-
tion with respect to voltage, current, anticipated tem-
CAUTION
perature, flammability, and mechanical serviceability.
The shielded RJ-45 port labeled Ethernet is the Auto-MDIX10/100Base- T interface. This port is designed to connect directly to a 10/100Base-T network.
Figure 4 shows the signal/pin relationships on this interface. You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long.
11
1 TX+/RX+
1 2 3 4 5 6 7 8
2 TX-/RX­3 RX+/TX+ 4 (no connection) 5 (no connection) 6 RX-/TX­7 (no connection) 8 (no connection)
Figure 4. Model 2173R 10/100Base-T RJ-45 Connector Pinout.

3.3 CONNECTING POWER

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica
-
tion with respect to voltage, current, anticipated tem-
CAUTION
perature, flammability, and mechanical serviceability.
The Model 2173R does not have a power switch, so it powers up as soon as it is plugged in.
An external AC or DC power supply is availab le se p arately. This conne c­tion is made via the barre l jack on the rear p anel of the M odel 2 173R. No configuration is necessary for the power supply (See Appendix B for domestic and international power supply and cord options).
DC power (supplied via the power supply jack to the 2173R) must meet the following requirements; DC power supplied must be regulated +5VDC ±5% , 1 .0A mi nim um . C e nte r pi n is +5V. The barrel type plug has a 2.5/5.5/10mm I.D./O.D./Shaft Length dimensions.

4.0 CONFIGURATION

The Model 2173 has four DIP switches (S1) for configuring the unit for a wide variety of applications. This section describes switch locations and explains the different configurations..

4.1 CONFIGURING THE HARDWARE DIP SWITCHES

Using a small fl at-t ip screw driv er, remove the protecti ve c over loc ated on the underside of the Model 2173R (see
Figure 5).
12
r
e
d
d
e
n
e
p
te
S
x
-
h
t E
ig
e
H
rn
e
th
E
Figure 5. Removing protective cover
Figure 6 on page 13 shows the orientation of the DIP switch es in the On and Off positions.
Ruggedized High Speed Ethernet Extender
S1
ON
OFF
Switch toggle
Push toggle up for ON position
Push toggle
down for
OFF position
Figure 6. DIP switch orientation
13
S1
ON
1234
ON
1234
S1

4.2 CONFIGURING DIP SWITCH S1

DIP switch S1 is whe re you con figure the CopperLI NK line. T he foll owing tables describe the configuration for the 2173.
Tab le 1: 2173 Firmware Confi guration
S1-1 S1-2 S1-3 S1-4
Position
ON Slave
Master/
Slave
Mode Rate SNR
Fast Auto 6dB
(CPE)
OFF Master
Interleave 25/25 9dB
(CO)
S1-2: Impulse Noise Protection
Fast Mode: Direct data transmission with latency less than 1ms
Interleave Mode: Provides data transmission protection for up to 250
ms impulse noise with latency less than 6 ms
S1-3: Rate Limit
S1-3 Rate
OFF 25/25
ON Auto
S1-4: General Protection (Signal to Noise Ratio)
6dB: Original line noise protection with 6dB SNR
9dB: Better line noise protection with SNR up to 9dB

5.0 OPERATION

Once the Model 2173Rs are properly installed, they should operate transparently. No user settings required. This section describes reading the LED status monitors.

5.1 POWER UP

Before applying power to the Model 2173R, please review section 3.3, “Connecting Power” on p age 12 to verify th at the un it is co nnecte d to the appropriate power source.
14

5.2 FRONT PANEL LED STATUS MONITORS

The Model 2173R features six front panel LEDs that monitor power, the Ethernet signals, the CopperLINK connection, and the remote/local set ting. Figure 7 shows the front panel location of each LED. Table 2 on page 15 describes the LED functions.
Power LED
o u
p
p
g
g
rL
e
d
e
Ethernet
2 1
Link LED
21
k
in
d
ize
Power
Link
Ethernet 1
Ethernet 2
Remote
Local
t E
R
e
73
rn
e
th
E
r
e
d
n
te
x
Power
5V; 0.6A
Line
Ethernet 1 LED
Ethernet 2 LED
Remote LED
Local LED
C R
Figure 7. Model 2173R front panel
Tab le 2: Front panel LED description
-
LED Status Description
Power Green The device is powered on.
Off The device is powered off.
CopperLink Green The port is connected.
Blinking Green Data transceiving. Off No valid link on this port.
Ethernet Green The port is connected.
*
Blinking Green
Data transceiving.
Local Green The device acts in Local mode.
Off Local mode is off.
Remote Green The device acts in Remote mode.
Off Remote mode is off.
*.
Once the unit connects to a power sourc e, the Link LED will blink as the 2173R automatically looks for the other unit in the pair.
15
APPENDIX A
SPECIFICATIONS

A.1 LAN CONNECTION

• Two shielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet
• CopperLINK Connection: Shielded RJ-45

A.2 TRANSMISSION LINE

Two-wire unconditioned twisted pair.

A.3 COPPERLINK LINE RATE AND COPPERLINK DISTANCE

• Line Rate: Up to 155 Mbps aggregate (upstream/downstream) via
Auto Rate; and 25/25 Mbps via DIP switch settings.
• Distance: Up to 5,500 ft (1.6 km)
Note Distances depend on line rate and line conditions.

A.4 LED STATUS INDICATORS

• Power (Green)
• CopperLINK: Link (Green)
• Ethernet: Link (Green) & Activity (Flashing Green)
• Remote (Green)
• Local (Green)

A.5 POWER SUPPLY

External AC and DC options:
• AC: 120 VAC, 220 VAC, and UI (120–240 VAC)
• DC: 12 VDC, 24 VDC and 48 VDC
• Power consumption: 860mA at 5V

A.6 TEMPERATURE RANGE

-40 to 85°C

A.7 HUMIDITY

Standard:Up to 90% non-condensing Conformal Coated: 85% condensing humidity from -10 to 35°C

A.8 DIMENSIONS

1.5H x 4.13W x 3.75D in.(3.81H x 10.5W x 9.53D cm)
16
APPENDIX B
MODEL 2173R FACTORY
REPLACEMENT PARTS AND ACCESSORIES
Patton Model # Description
Base Models
2173R/E Co pperLINK Multi Rate 100 Mbps Ethernet Extender;
No power supply
2173R/E-2PK CopperLINK Multi Rate 100 Mbps Ethernet Extender Kit (2 units
2173R/EUI-2PK CopperLINK Multi Rate 100 Mbps Ethernet Extender Kit (2 units
07M2173R-UM
preset to local and remote); No power supply
preset to local and remote); 110-240VAC User Manual
Power Supplies
08055DCUI 08055-120-5-1
12V-PSM 12 VDC Input Adapter 24V-PSM 24 VDC Input Adapter 48V-PSM 48 VDC Input Adapter
100-240VAC (+5V reg. DC/2A) Universal Input Adapter. 120 VAC (+5V reg. DC/1A) Input Adapter
Power Cords*
0805US American Power Cord 0805EUR European Power Cord CEE 7 0805UK United Kingdom Power Cord 0805AUS Australian Power Cord 0805DEN Denmark Power Cord 0805FR France/Belgium Power Cord 0805IN India Power Cord 0805IS Israel Power Cord 0805JAP Ja pan Power Cord 0805SW Switzerland Power Cord
*Only required with optional UI power supply (08055DCUI)
17
APPENDIX C
MODEL 2173R INTERFACE PIN ASSIGNMENT

C.1 10/100BASE-T INTERFACE

RJ-45

• Pin 1: TX+
• Pin 2: TX-
• Pin 3: RX+
• Pin 6: RX-
• Pins 4, 5, 7, 8: no connection

C.2 COPPERLINK INTERFACE

RJ-45

• Pin 4: RING
• Pin 5: TIP
• Pins 1, 2, 3, 6, 7, 8: no connection
18
APPENDIX D
SAMPLE RATES/DISTANCE CHART, BASED ON 24 AWG (0.5 MM)
Throughput
at Max
Distance
(megabits per
Rate Mode
Distance in
Feet (km)
second)
4/1 Fast 5,500
(1.6 km)
4/1 Interleave 5,500
(1.6 km)
100/70 Fast 500 ft
(0.15 km)
100/70 Interleave 250
(0.07 km)
25/25
*
Interleave 2,250
(0.6 km)
50/50 Fast 1,750
(0.5 km)
50/50 Interleave 1,750
(0.5 km)
70/70 Fast 1,750
(0.5 km)
70/70 Interleave 1,750
(0.5 km)
4.00 (DS)
1.00 (US)
4.00 (DS)
1.00 (US) 83 (DS)
69.5 (US) 83 (DS)
69.5 (US)
24.89 (DS)
24.89 (US)
49.78 (DS)
49.78 (US)
49.78 (DS)
49.78 (US) 51 (DS)
51 (US) 51 (DS)
51 (US)
*. For the 25/25 rate, set S1-3 to the OFF position.
Note The actual distance and link performance may vary depending
on the environment and type/gauge of wire used.
Note DS = downstream, US = upstream
19
Copyright © 2011
Patton Electronics Company
All Rights Reserved.
20
Loading...