Patton 2172 User Manual

USER MANUAL
MODEL 2172
CopperLINK™ High Speed Ethernet Extenders
An ISO-9001Certified
Company
Part# 07M2172-UM Doc# 03333U2-001
Rev. A Revised 10/24/06
SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007
CONTENTS
1.0 Warranty Information ................................................................. 4
1.1 Compliance................................................................................... 4
EMC Compliance:......................................................................... 4
Safety Compliance: ...................................................................... 4
1.2 Radio and TV Interference (FCC Part 15).................................... 4
1.3 Declaration of Conformity............................................................. 5
1.4 Service.......................................................................................... 5
1.5 Safety When Working With Electricity .......................................... 6
2.0 General Information.................................................................... 7
2.1 Features........................................................................................ 7
2.2 Description.................................................................................... 7
3.0 Installation................................................................................... 8
3.1 Connecting the Twisted-Pair Line Interface.................................. 9
3.2 Connecting the 10/100Base-T Ethernet Interface ...................... 11
3.3 Connecting Power ...................................................................... 12
4.0 Configuration ............................................................................ 12
4.1 Configuring the hardware DIP switches...................................... 12
4.2 Configuring DIP Switch S2 ......................................................... 14
Switch S2-1: Symmetric/Asymmetric Operation......................... 14
Switches S2-2 and S2-3: Data Rate........................................... 14
5.0 Operation................................................................................... 16
5.1 Power Up.................................................................................... 16
5.2 Front Panel LED Status Monitors............................................... 16
A
Specifications ........................................................................... 18
A.1 LAN Connection .......................................................................... 18
A.2 Transmission Line ....................................................................... 18
A.3 CopperLINK Line Rate and CopperLINK Distance .................... 18
A.4 CopperLINK Surge Suppressor .................................................. 18
A.5 LED Status Indicators ................................................................. 18
A.6 Power Supply .............................................................................. 18
A.7 Temperature Range .................................................................... 18
A.8 Humidity ...................................................................................... 18
A.9 Dimensions ................................................................................. 18
B
Model 2172 Series Factory
Replacement Parts and Accessories...................................... 19
C
Model 2172 Series Interface Pin Assignment ........................ 20
2
C.1 10/100Base-T Interface .............................................................. 20
RJ-45.......................................................................................... 20
C.2 CopperLINK Interface ................................................................. 20
RJ-45.......................................................................................... 20
Terminal Block............................................................................ 20
D
Distance Chart, Based on 24 AWG (0.5 MM).......................... 21
3

1.0 WARRANTY INFORMATION

Patton Electronics
warrants all Model 2172 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of the shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not performs as warranted, y our sole recourse shall be repair or replacement as described above. Under no condition shall
Patton Electronics
be liable for any damages incurred b y the use of this product. These damages include, but are not limited to , the f ollo wing: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product.
Patton Electronics
spe­cifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.
Note
Conformity documents of all Patton products can be viewed online at www.patton.com under the appropriate product page.

1.1 COMPLIANCE

EMC Compliance:

• FCC Part 15, Class A
• EN55022, Class A
• EN55024

Safety Compliance:

• IEC/EN 60950-1
• AS/NZS 60950-1

1.2 RADIO AND TV INTERFERENCE (FCC PART 15)

This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manu­facturer's instructions—may cause interference to radio and television reception. This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifica­tions in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installa­tion. However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or
4
television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re­orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).

1.3 DECLARATION OF CONFORMITY

We certify that the apparatus identified in this document conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Ter­minal Equipment and the mutual recognition of their conformity.
The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above directive is indicated by the CE sign on the device.

1.4 SERVICE

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materi­als Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Services at:
• Tel: +1
• Email:
• URL:
Note
(301) 975-1007
support@patton.com
http://www.patton.com
Packages received without an RMA number will not be accepted.
5

1.5 SAFETY WHEN WORKING WITH ELECTRICITY

• This device contains no user serviceable parts. The equipment shall be returned to Patton Electronics for repairs, or repaired by qualified service personnel.
• Mains Voltage: Ensure that the external power adapter is a listed Limited Power Source. The mains outlet that is utilized to power the devise shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker. Ensure that the power cable used meets all applicable standards for the coun­try in which it is to be installed, and that it is connected to a wall outlet which has earth ground.
WARNING
• Hazardous network voltages are present in WAN ports regardless of whether power to the unit is ON or OFF. To avoid electric shock, use caution when near WAN ports. When detaching the cables, detach the end away from the device first.
• Do not work on the system or connect or disconnect cables during periods of lightning activity.
In accordance with the requirements of council direc­tive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you sepa­rate this product from other waste and scrap and deliver to the WEEE collection system in your country for recy­cling.
6

2.0 GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for one year for parts and labor. If any questions or problems arise during installation or use of this product, contact Patton Electronics Technical Support at +1 (301) 975-1007.

2.1 FEATURES

• Variable rate CopperLINK extender - Easy to configure
• Auto-MDIX Ethernet
• Configurable 10/100, Full/Half, and Auto-Negotiating Ethernet
• Extends network connections up to 6,000 ft (1.8 km) over 2-wire 24-
AWG unconditioned lines
• Switch selectable line rates up to 50 Mbps
• 6 symmetric or asymmetric settings via DIP switch
• Transparent operation
• LED indicators for Pow er , Link, and Ethernet Link & Activity
• Surge suppression up to 20 kA (8/20 µs)
• Made in the USA

2.2 DESCRIPTION

The Patton Electronics Model 2172 CopperLink modems provide high­speed LAN connections between peered Ethernet LANs, remote PC’s, or any other network enabled 10/100Base-T device.
Operating in pairs, one Model 2172 is configured as the (L) Local unit located at one end of the LAN extension and the other Model 2172 is con­figured as the (R) Remote unit at the other end. The Model 2172 is config­ured as a L or R via the switch on the rear panel. These units can automatically forward LAN broadcasts, multicasts, and frames across a 2­wire voice-grade twisted-pair link. The data is passed transparently (unmodified) through the 2172s. The 2172s automatically add and delete MAC addresses, only passing pack ets across the CopperLINK link that are meant for the remote peered LAN.
7
Figure 1.
Typical application
The pair of 2172 models work together to create a transparent extension between two peered Ethernet LANs. Figure 1 shows a typical point-to­point application.

3.0 INSTALLATION

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica­tion with respect to voltage, current, anticipated tem-
CAUTION
perature, flammability, and mechanical serviceability.
To install the 2172 Ethernet Extender, do the following:
1. Connect the line interface between the units (refer to section 3.1,
“Connecting the Twisted-Pair Line Interface” on page 9)
Note
See Figure 2 for the standalone unit’s rear panel arrangements.
2. Connect the Ethernet interface (refer to section 3.2, “Connecting the
10/100Base-T Ethernet Interface” on page 11).
3. Connect the power plug (refer to section 3.3, “Connecting P ow er” on
page 12).
8
2172
Made in the USA
Power
(RJ-45)
Power
jack
Ethernet
port
Ethernet
Rem Loc
Line
Local/Remote
CopperLINK twisted-pair
RJ-45 interface
2172
(Terminal block)
Ethernet
Rem Loc
Local/Remote
switch
CopperLINK twisted-pair
terminal block
interface
Figure 2.
Model 2172 standalone rear panel

3.1 CONNECTING THE TWISTED-PAIR LINE INTERFACE

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica­tion with respect to voltage, current, anticipated tem-
CAUTION
perature, flammability, and mechanical serviceability.
Made in the USA
Power
switch
Power
jack
Ethernet
port
The Model 2172 supports communication between two peer Ethernet LAN sites over a distance of up to 6,000 ft (1.8 km) over 24 AWG (0.5 mm) twisted-pair wire.
Note
Actual distance and link performance may vary depending on the environment and type/gauge of wire used.
Follow the steps below to connect the Model 2172 CopperLINK Inter­faces.
Note
The Model 2172 units work in pairs. One of the units must be configured as a (L) Local unit, and the other unit must be config­ured as a (R) Remote unit. It does not matter which end is the L and which is the R. The link is always initiated by the R unit. As long as the L unit is powered on, the R unit can establish a link by being powered on or by having its power reset.
1. To function properly, the two Model 2172s must be connected
together using twisted-pair, unconditioned, dry, metal wire, between
9
19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.
2. The Model 2172 is equipped with either an RJ-45 or a terminal block
interface jack that can be used on the CopperLINK interf ace. These CopperLINK interfaces are a two-wire interface. Observe the signal/
pin relationships on the Model 2172's CopperLINK interface jacks.
The Line port has been classified as TNV-1 and is approved for connection to a PSTN TNV-1 circuit.
WARNING
The RJ-45 connector on the Model 2172's twisted pair interface is polar­ity insensitive and is wired for a two-wire interface. The signal/pin rela­tionship is shown in Figure 3.
1 (no connection)
1 2 3 4 5 6 7 8
Figure 3.
Model 2172 (RJ-45) twisted pair line interface.
The terminal block connector on the Model 2172's twisted pair interface is polarity insensitive and is wired for a two-wire interface. The signal/pin relationships is shown in Figure 4.
2 (no connection) 3 (no connection) 4 (RING) 5 (TIP) 6 (no connection) 7 (no connection) 8 (no connection)
10
Made in the USA
Power
Ethernet
Rem Loc
RING TIP
Figure 4.
Model 2172 (Terminal Block) twisted pair line interface.

3.2 CONNECTING THE 10/100BASE-T ETHERNET INTERFACE

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica­tion with respect to voltage, current, anticipated tem-
CAUTION
perature, flammability, and mechanical serviceability.
The shielded RJ-45 port labeled
Ethernet
is the Auto-MDIX10/100Base­T interface. This port is designed to connect directly to a 10/100Base-T network. Figure 5 shows the signal/pin relationships on this interface. You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long.
1 TX+/RX+
1 2 3 4 5 6 7 8
2 TX-/RX­3 RX+/TX+ 4 (no connection) 5 (no connection) 6 RX-/TX­7 (no connection) 8 (no connection)
Figure 5.
Model 2172 10/100Base-T RJ-45 Connector Pinout.
11

3.3 CONNECTING POWER

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica­tion with respect to voltage, current, anticipated tem-
CAUTION
The Model 2172 does not have a power switch, so it powers up as soon as it is plugged in.
An external AC or DC power supply is available separately. This connec­tion is made via the barrel jack on the rear panel of the Model 2172. No configuration is necessary for the power supply (See Appendix B for domestic and international power supply and cord options).
DC power (supplied via the power supply jack to the 2172) must meet the following requirements; DC power supplied must be regulated +5VDC ±5%, 1.0A minimum. Center pin is +5V. The barrel type plug has a 2.5/5.5/10mm I.D./O.D./Shaft Length dimensions.
The Model 2172 has eight DIP switches for configuring the unit f or a wide variety of applications. This section describes switch locations and explains the different configurations.
perature, flammability, and mechanical serviceability.

4.0 CONFIGURATION

4.1 CONFIGURING THE HARDWARE DIP SWITCHES

Using a small flat-tip screwdriver , remov e the protectiv e co v er located on the underside of the Model 2172 (see Figure 6).
12
CopperLINK™
Link
Ethernet
High Speed Ethernet Extender
Power
Figure 6.
Removing protective cover
Figure 7 on page 13 shows the orientation of the DIP switches in the On and Off positions.
S2
S2
1234ON5 6 7 8
RearFront
Switch toggle
S2
ON
8
7
6
5
1234
Push toggle up for ON position
ON
S2
Push toggle
down for
OFF position
1234
5678
Figure 7.
DIP switch orientation
13

4.2 CONFIGURING DIP SWITCH S2

DIP switch S2 is where you configure the CopperLINK line rate , symmet­ric or asymmetric, Ethernet, and Ethernet Shutdown. Table 1 summa­rizes default positions of DIP switches S2-1 through S2-8. Detailed descriptions of each switch follow the table.
Table 1:
S2 Summary
Position Description
S2-1 Symmetric/Asymmetric S2-2 Line Rate S2-3 Line Rate S2-4 Ethernet configuration S2-5 Ethernet configuration S2-6 Ethernet configuration S2-7 Ethernet Shutdown S2-8 Remote Configuration

Switch S2-1: Symmetric/Asymmetric Operation

Use switch S2-1 to configure the unit for symmetric or asymmetric opera­tion..
Table 2:
Ethernet Auto Sense Selection Chart
S2-1 Setting
ON Symmetric Operation
OFF Asymmetric Operation

Switches S2-2 and S2-3: Data Rate

Use switches S2-1, S2-2 and S2-3 to configure the CopperLINK line rates.
Table 3:
Symmetric CopperLINK Line Rates Selection Chart
S2-2 S2-3 Symmetric Line Rate
OFF ON 50 Mbps
ON OFF 25 Mbps
OFF OFF 10 Mbps
14
Table 4:
Asymmetric CopperLINK Line Rates Selection Chart
S2-2 S2-3 Asymmetric Line Rates DS/US
ON ON 50 Mbps/2 Mbps ON OFF 16 Mbps/2 Mbps
OFF OFF 4 Mbps/1 Mbps
Switches S2-4, S2-5 and S2-6: Ethernet Configuration
Use switches S2-4, S2-5 and S2-6 to configure Ethernet settings.
Table 5:
Ethernet configurations
S2-4 S2-5 S2-6 Ethernet Configurations
ON ON ON Auto-Negotiate ON ON OFF 100Mb Full Duplex ON OFF ON 100Mb Half Duplex ON OFF OFF 10Mb Full Duplex
OFF ON ON 10Mb Half Duplex
Switch S2-7: Ethernet Shutdown
Use switch S2-7 to enable or disable Ethernet Shutdown. When Ethernet Shutdown is enabled, the 2172 will disable the Ethernet interface when there is no CopperLINK link detected. When Ethernet Shutdown is dis­abled, the Ethernet interface will always be enabled.
Table 6:
Ethernet Shutdown
S2-7 Description
ON Ethernet Shutdown Enabled
OFF Ethernet Shutdown Disabled
Switch S2-8: Remote Configuration
Use switch S2-8 to enable or disable Remote Configuration.
Table 7:
Ethernet Shutdown
S2-8 Description
ON Remote Configuration Enabled
OFF Remote Configuration Disabled
Note
The S2-8 switch applies to the R unit only. If enabled, the R will follow the dip switch configur ation of the L unit. If disabled, the R unit will use its own dip switch setting to determine its Ethernet
15
operating mode and Ethernet Shutdown mode configuration. The S2-8 switch does not affect the data rate. The data rate will always follow the L configuration.

5.0 OPERATION

Once the Model 2172s are properly installed, they should operate trans­parently. No user settings required. This section describes reading the LED status monitors.

5.1 POWER UP

Before applying power to the Model 2172, please review section 3.3, “Connecting Pow er” on page 12 to verify that the unit is connected to the appropriate power source.

5.2 FRONT PANEL LED STATUS MONITORS

The Model 2172 features three front panel LEDs that monitor power, the Ethernet signals, and the CopperLINK connection. Figure 8 shows the front panel location of each LED. Table 8 on page 17 describes the LED functions.
16
Power
CopperLINK
High Speed Ethernet Extender
Ethernet
Link
Power
Ethernet LED
LED
Link LED
Figure 8.
Model 2172 standalone unit front panel
Table 8:
Front panel LED description
LED Description
PWR Solid GREEN to indicate the unit is powered on. LINK Solid GREEN (ON) to indicate that the end-to-end
CopperLINK link between the Model 2172s is estab­lished. The Link LED is OFF when the link is down.
ETH Solid GREEN indicates that 10/100Base-T Ethernet
link has been established. Flashes to indicate activity.
17
APPENDIX A
SPECIFICATIONS

A.1 LAN CONNECTION

• Shielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet
• CopperLINK Connection: RJ-45 or Terminal Block

A.2 TRANSMISSION LINE

Two-wire unconditioned twisted pair.

A.3 COPPERLINK LINE RATE AND COPPERLINK DISTANCE

• Line Rate: 50 Mbps, symmetric upstream/downstream. Additional
symmetric and asymmetric rates are available via DIP s witch settings.
• Distance: 6,000 ft (1.8 km) at 1 Mbps upstream/4 Mbps downstream
Note
Distances depend on selected line rate and line conditions. See Appendix D on page 21 for details.

A.4 COPPERLINK SURGE SUPPRESSOR

SIDACTOR with maximum current surge: 20 kA (8/20 µs).

A.5 LED STATUS INDICATORS

• Power (Green)
• CopperLINK: Link (Green)
• Ethernet: Link (Green) & Activity (Flashing Green)

A.6 POWER SUPPLY

External AC and DC options:
• AC: 120 VAC, 220 VAC, and UI (120–240 VAC)
• DC: 12 VDC, 24 VDC and 48 VDC
• Power consumption: 450 mA at 5 VDC

A.7 TEMPERATURE RANGE

0–50°C

A.8 HUMIDITY

Up to 90% non-condensing.

A.9 DIMENSIONS

1.58H x 4.16W x 3.75D in. (10.6H x 4.1W x 8.8D cm)
18
APPENDIX B
MODEL 2172 SERIES FACTORY
REPLACEMENT PARTS AND ACCESSORIES
Patton Model # Description
Base Models
2172/E CopperLINK Multi Rate 50 Mbps Ethernet Extender;
No power supply
2172/E-2PK CopperLINK Multi Rate 50 Mbps Ethernet Extender Kit (2 units pre-
set to local and remote); No power supply
2172/EUI-2PK CopperLINK Multi Rate 50 Mbps Ethernet Extender Kit (2 units pre-
set to local and remote); 110-240VAC
07M2172-UM
User Manual
Power Supplies
08055DCUI 08055-120-5-1
12V-PSM 12 VDC Input Adapter 24V-PSM 24 VDC Input Adapter 48V-PSM 48 VDC Input Adapter
100-240VAC (+5V reg. DC/2A) Universal Input Adapter. 120 VAC (+5V reg. DC/1A) Input Adapter
Power Cords*
0805US American Power Cord 0805EUR European Power Cord CEE 7 0805UK United Kingdom Power Cord 0805AUS Australian Power Cord 0805DEN Denmark Power Cord 0805FR France/Belgium Power Cord 0805IN India Power Cord 0805IS Israel Power Cord 0805JAP Japan Power Cord 0805SW Switzerland Power Cord
*Only required with optional UI power supply (08055DCUI)
19
APPENDIX C
MODEL 2172 SERIES INTERFACE PIN ASSIGNMENT

C.1 10/100BASE-T INTERFACE

RJ-45

• Pin 1: TX+
• Pin 2: TX-
• Pin 3: RX+
• Pin 6: RX-
• Pins 4, 5, 7, 8: no connection

C.2 COPPERLINK INTERFACE

RJ-45

• Pin 4: RING
• Pin 5: TIP
• Pins 1, 2, 3, 6, 7, 8: no connection

Terminal Block

Figure 1. Model 2172 (Terminal Block) twisted pair line interface..
Made in the USA
Power
Ethernet
Rem Loc
RING TIP
20
APPENDIX D
DISTANCE CHART, BASED ON 24 AWG (0.5 MM)
Symm Line Rate
Distance in feet
(km)
Throughput
at Max Distance
50 Mbps 800 (0.25 km) 48 25 Mbps 2,000 (0.61 km) 24.5 10 Mbps 4,000 (1.22 km) 10
Asymm Line Rate
(DS/US)
Distance in feet
(km)
Throughput
at Max Distance
(DS/US)
50 Mbps/2 Mbps 2,000 (0.61 km) 48/2 16 Mbps/2 Mbps 4,000 (1.22 km) 15/2
4 Mbps/1 Mbps 6,000 (1.82 km) 3.75/1
Note The actual distance and link performance may vary depending
on the environment and type/gauge of wire used.
Note DS = downstream, US = upstream