Patton 2158A, 2168A User Manual

USER MANUAL
CopperLink™ Ethernet Extenders Models 2168A and 2158A
This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in an industrial or residential environment.
Part# 07M2168A-UM Rev. A
Revised 10/8/08
An ISO-9001Certified
Company
CONTENTS
1.0 Warranty Information ................................................................. 4
1.1 Compliance................................................................................... 4
EMC Compliance:......................................................................... 4
Safety Compliance: ...................................................................... 4
PSTN Compliance:....................................................................... 4
1.2 Radio and TV Interference (FCC Part 15) .................................... 5
1.3 CE Declaration of Conformity ....................................................... 5
1.4 Authorized European Representative........................................... 5
1.5 Service.......................................................................................... 5
1.6 Safety When Working With Electricity .......................................... 6
2.0 General Information.................................................................... 7
2.1 Features........................................................................................ 7
2.2 Description.................................................................................... 8
3.0 Installation................................................................................... 9
3.1 Unit Installation ............................................................................. 9
3.2 Grounding the CopperLink Ethernet Extender............................ 10
3.3 Connecting the Twisted-Pair Line Interface................................ 10
Using a Ferrite Clamp to Connect the Line Interface ................. 12
Connecting the ferrite clamp to the RJ-45 port. ................... 12
Connecting the ferrite clamp to the terminal block. ............. 13
3.4 Connecting the 10/100Base-T Ethernet Interface ...................... 14
3.5 Connecting Power ...................................................................... 15
4.0 Configuration ............................................................................ 16
4.1 Configuring the hardware DIP switches...................................... 16
4.2 Configuring DIP Switch SW ........................................................ 17
Switches SW-2 and SW-4: Data Rate........................................ 17
5.0 Operation................................................................................... 18
5.1 Power Up .................................................................................... 18
5.2 Front Panel LED Status Monitors ............................................... 18
A
Specifications ........................................................................... 20
A.1 LAN Connection .......................................................................... 20
A.2 Transmission Line ....................................................................... 20
A.3 CopperLink Line Rate ................................................................. 20
A.4 CopperLink Distance .................................................................. 20
A.5 CopperLink Surge Suppressor ................................................... 20
A.6 LED Status Indicators ................................................................. 20
A.7 Power Supply .............................................................................. 21
A.8 Temperature Range .................................................................... 21
A.9 Humidity ...................................................................................... 21
A.10 Dimensions ................................................................................. 21
2
B
Model 2168A and 2158A Series Factory
Replacement Parts and Accessories...................................... 22
C
CopperLink Series Interface Pin Assignment........................ 24
C.1 10/100Base-T Interface .............................................................. 24
RJ-45.......................................................................................... 24
C.2 CopperLink Interface .................................................................. 24
RJ-45.......................................................................................... 24
Terminal Block............................................................................ 24
D
Distance Chart, Based on 24 AWG (0.5 MM).......................... 25
3

1.0 WARRANTY INFORMATION

Patton Electronics
warrants all CopperLink Ethernet Extender compo­nents to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of the ship­ment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not performs as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall
Patton Electronics
be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product.
Patton Electronics
spe­cifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.
Note
Conformity documents of all Patton products can be viewed online at www.patton.com under the appropriate product page.

1.1 COMPLIANCE

EMC Compliance:

• FCC Part 15, Class A
• EN55022, Class A
• EN55024

Safety Compliance:

• IEC/EN 60950-1
• AS/NZS 60950-1

PSTN Compliance:

Note
This device is not intended nor approved for connection to the PSTN.
4

1.2 RADIO AND TV INTERFERENCE (FCC PART 15)

This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manu­facturer's instructions—may cause interference to radio and television reception. This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifica­tions in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installa­tion. However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re­orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).

1.3 CE DECLARATION OF CONFORMITY

We certify that the apparatus described above conforms to the require­ments of Council Directive 2004/108/EC on the approximation of the laws of the member states relating to electromagnetic compatibility; and Council Directive 2006/95/EC on the approximation of the laws of the member states relating to electrical equipment designed for use within certain voltage limits.

1.4 AUTHORIZED EUROPEAN REPRESENTATIVE

D R M Green European Compliance Services Limited. Avalon House, Marcham Road Abingdon, Oxon OX14 1UD, UK

1.5 SERVICE

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materi­als Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Services at:
• Tel: +1
• Email:
• URL:
(301) 975-1007
support@patton.com
http://www.patton.com
5
Note
Packages received without an RMA number will not be accepted.

1.6 SAFETY WHEN WORKING WITH ELECTRICITY

• This device contains no user serviceable parts. The equipment shall be returned to Patton Electronics for repairs, or repaired by qualified service personnel.
• The external power adapter shall be a listed Limited Power Source. Ensure that the power cable used meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground. The mains
WARNING
outlet that is utilized to power the devise shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker.
• Do not work on the system or connect or disconnect cables during periods of lightning activity.
In accordance with the requirements of council direc­tive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you sepa­rate this product from other waste and scrap and deliver to the WEEE collection system in your country for recy­cling.
WARNING
WARNING
This device is NOT intended nor approved for connec­tion to the PSTN. It is intended only for connection to customer premise equipment.
The Interconnecting cables shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceabil­ity
6

2.0 GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for one year for parts and labor. If any questions or problems arise during installation or use of this product, contact Patton Electronics Technical Support at +1 (301) 975-1007.

2.1 FEATURES

• Easy to install CopperLink Ethernet Extenders (no configuration required)
• Auto MDIX Ethernet
• Auto-sensing full or half-duplex Ethernet
• Auto-sensing 10/100Base-TX
• Extends network connections up to 6,000 ft (1.83 km) over 2-wire 24­AWG unconditioned lines
• Switch selectable line rates up to 16.67 Mbps
• 7 total symmetric or asymmetric settings via DIP switch (2168A and 2168A/TB45 models only)
• Transparent operation
• LED indicators for Power, Ethernet Link & Activity, CopperLink link & Quality of Line (QOL)
• Surge suppression up to 200 kA (8/20 μs)
• Made in the USA
7

2.2 DESCRIPTION

The Patton Electronics CopperLink/L and CopperLink/R Ethernet Extenders provide high-speed LAN connections between peered Ether­net LANs, remote PCs, or any other network enabled 10/100Base-T device.
Operating in pairs, a CopperLink/L (local) located at one end of the LAN extension and a CopperLink/R (remote) at the other end, these units can automatically forward LAN broadcasts, multicasts, and frames across a 2­wire voice-grade twisted-pair link. The data is passed transparently (unmodified) through the CopperLink Ethernet Extenders. The CopperLink Ethernet Extenders automatically add and delete MAC addresses, only passing packets across the CopperLink link that are meant for the remote peered LAN.
Figure 1.
Typical application
The CopperLink/Lunit and CopperLink/R unit work together to create a transparent extension between two peered Ethernet LANs. Figure 1 shows a typical point-to-point application.
8

3.0 INSTALLATION

Because the CopperLink Ethernet Extender requires no configuration, it can be installed quickly.
Note
If asymmetric transmission or line rates other than 12.5 Mbps are required , refer to section 4.0, “Configuration” on page 16.

3.1 UNIT INSTALLATION

Do the following:
1. Make a ground connection for the unit (refer to section 3.2, “Ground-
ing the CopperLink Ethernet Extender” on page 10).
2. Connect the line interface between the units (refer to section 3.3,
“Connecting the Twisted-Pair Line Interface” on page 10)
Note
See Figure 2 for the unit’s rear panel arrangements.
3. Connect the Ethernet interface (refer to section 3.4, “Connecting the
10/100Base-T Ethernet Interface” on page 14).
4. Connect the power plug (refer to section 3.5, “Connecting Power” on
page 15).
CopperLink 2168A/TB45
CopperLink 2168A CopperLink 2158A
Ground
Ethernet
stud
CopperLink twisted-pair
RJ-45 interface
Figure 2.
CopperLink Ethernet Extender rear panel
Power
connector
port
9
Ground
stud
Power
connector
Ethernet
port
CopperLink twisted-pair
terminal block
interface
CopperLink twisted-pair
RJ-45 interface

3.2 GROUNDING THE COPPERLINK ETHERNET EXTENDER

Before installing the CopperLink Ethernet Extender, it is important to establish a good grounding connection first.
1. Assemble a ground wire using #10 AWG wire with green-and-yel-
low-colored insulation and two ring terminals. Make the wire long enough to reach one of the following
earth
ground sources:
— The building ground rod (generally located at the site’s main
service entrance)
— A sprinkler system pipe
— A metal cold-water pipe
— Building structural steel
2. Install the grounding wire between the grounding stud (see Figure 2
on page 9) and the grounding source.

3.3 CONNECTING THE TWISTED-PAIR LINE INTERFACE

The CopperLink Ethernet Extender supports communication between two peer Ethernet LAN sites over a distance of up to 6,000 ft (1.83 km) over 24 AWG (0.5 mm) twisted-pair wire.
Note
Actual distance and link performance may vary depending on the environment and type/gauge of wire used.
Follow the steps below to connect the CopperLink Ethernet Extenders interfaces.
Note
The CopperLink units work in pairs. One of the CopperLink units must be an L (local), and the other unit must be an R (remote). It does not matter which end is the L and which is the R. The link is always initiated by the R. As long as the L is powered on, the R can establish a link by being powered on or by having its power reset.
1. To function properly, the two CopperLink Ethernet Extenders must
be connected together using twisted-pair, unconditioned, dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.
2. The CopperLink Ethernet Extenders are equipped with an interface
jack that can be used on the CopperLink interface, an RJ-45 (2168A or 2158A), or a terminal block (2168A/TB45, which also has the RJ­45 interface). These CopperLink interfaces are a two-wire interface. Observe the signal/pin relationships on the CopperLink Ethernet Extender's CopperLink interface jacks.
10
The
RJ-45 connector
pair interface
is polarity insensitive
on the CopperLink Ethernet Extender's twisted
and is wired for a two-wire inter-
face. The signal/pin relationship is shown in Figure 3.
1 (no connection)
1 2 3 4 5 6 7 8
2 (no connection) 3 (no connection) 4 (2-Wire RING) 5 (2-Wire TIP) 6 (no connection) 7 (no connection) 8 (no connection)
Figure 3.
The
terminal block connector
twisted pair interface
CopperLink Ethernet Extender (RJ-45) twisted pair line interface.
on the CopperLink Ethernet Extender's
is polarity insensitive
and is wired for a two-wire
interface. The signal/pin relationships are shown in Figure 4.
Figure 4.
RING TIP
CopperLink2168A/TB45 Ethernet Extender twisted pair line interface.
11

Using a Ferrite Clamp to Connect the Line Interface

• The ferrite clamp that is shipped with the unit must be used as detailed in the following instructions in order to meet EMC requirements.
WARNING
Connecting the ferrite clamp to the RJ-45 port.
To connect the ferrite clamp to the RJ-45 port:
1. Place the RJ-45 cable inside the ferrite clamp, leaving about 1-2 inches of cable between the unit and clamp.
2. Wrap the cable tightly around the clamp two times and secure the wire firmly in the clamp channel.
3. Close the clamp and connect the cable to the line port on the unit (See Figure 2 on page 9).
Model 2168A Model 2158A
CopperLink twisted-pair
RJ-45 interface
Figure 5.
Connecting the ferrite clamp for 2168A/2158A models
Note: Be sure to leave 1-2 inches of cable between the unit and the ferrite clamp.
Ferrite clamp
12
Connecting the ferrite clamp to the terminal block.
To connect the ferrite clamp to the terminal block:
1. Place the cable inside the ferrite clamp, leaving about 1-2 inches of cable between the unit and clamp.
2. Wrap the cable tightly around the clamp two times and secure the wire firmly in the clamp channel.
3. Close the clamp and connect the cable to the line port on the unit (See Figure 2 on page 9).
Model 2168A/TB45
Note: Be sure to leave 1-2 inches of cable between the unit and the ferrite clamp.
CopperLink twisted-pair
RJ-45 interface
CopperLink twisted-pair
terminal block
Figure 6.
Connecting the ferrite clamp for 2168A/TB45 models
interface
Ferrite clamp
13

3.4 CONNECTING THE 10/100BASE-T ETHERNET INTERFACE

The RJ-45 port labeled
Ethernet
is the Auto-MDIX10/100Base-T inter­face. This port is designed to connect directly to a 10/100Base-T net­work. Figure 7 shows the signal/pin relationships on this interface. You may connect this port to a hub or PC using a straight through or cross­over cable that is up to 328 ft long.
1 TX+/RX+ (data output from CopperLink) 2 TX-/RX- (data output from Copperlink) 3 RX+/TX+ (data input to CopperLink) 4 (no connection) 5 (no connection) 6 RX-/TX-(data input to CopperLink) 7 (no connection) 8 (no connection)
Figure 7.
1 2 3 4 5 6 7 8
CopperLink Ethernet Extender 10/100Base-T RJ-45 Connector Pinout.
14

3.5 CONNECTING POWER

• Do not connect power to the DC Mains at this time.
• There are no user-serviceable parts in the power supply sec tion of the CopperLink Ethernet Extender. Contact Patton Elec-
WARNING
tronics Technical support at (301)975-1007, via our web site at http://www.patton.com, or by e-mail at support@pat­ton.com, for more information.
An external AC or DC power supply is available separately. This connec­tion is made via the barrel jack on the rear panel of the CopperLink Ethernet Extender. No configuration is necessary for the power supply (See Appendix B for domestic and international power supply and cord options).
DC power (supplied via the power supply jack to the CopperLink Ether­net Extender) must meet the following requirements; DC power supplied must be regulated +5VDC ±5%, 1.0A minimum. Center pin is +5V. The barrel type plug has a 2.5/5.5/10mm I.D./O.D./Shaft Length dimensions.
The CopperLink Ethernet Extender does not have a power switch, so it powers up as soon as it is plugged in.
15

4.0 CONFIGURATION

The CopperLink Models 2168A and 2168A/TB45 have an eight-position DIP switch for configuring the unit for a wide variety of applications. This section describes switch locations and explains the different configura­tions. The Model 2158A does not include dip switches.

4.1 CONFIGURING THE HARDWARE DIP SWITCHES

Using a small flat-tip screwdriver, remove the protective cover located on the underside of the CopperLink Ethernet Extender (see Figure 8).
C
o p p
e
r L i
n
k
CopperLink™ Ethernet Extender
Figure 8.
Removing protective cover
Figure 9 on page 16 shows the orientation of the DIP switches in the On and Off positions.
SW
SW
Figure 9.
Models 2168A and 2168A/TB45 DIP switch orientation
16

4.2 CONFIGURING DIP SWITCH SW

DIP switch SW is where you configure the CopperLink line rate, and if the rate is symmetric or asymmetric.

Switches SW-2 and SW-4: Data Rate

Use switches SW-2 and SW-4 to configure the CopperLink line rates.
Table 1:
Symmetric CopperLink Line Rates Selection Chart
SW-2
ON
SW-3 SW-4 Symmetric Line Rate
ON ON 6.25 Mbps ON ON OFF 9.38 Mbps ON OFF OFF
ON
OFF ON 16.67 Mbps
12.5 Mbps (Factory Default)
*. Model 2158A only has one symmetric line
rate setting, which is 12.5 Mbps.
Note
Table 2 only applies to Models 2168A and 2168A/TB45.
Table 2:
Model 2168A and 2168A/TB45 Asymmetric CopperLink Line Rates Selection Chart
SW-2 SW-3 SW-4
Asymmetric Line Rates DS/US
OFF OFF ON 4.17 Mbps/1.56 Mbps OFF ON ON 9.38 Mbps/1.56 Mbps OFF ON OFF 16.67 Mbps/2.34 Mbps
*. DS = downstream from L unit to R unit
US = upstream from R unit to L unit
Switches SW-1 and SW-5 through SW-8: Reserved
Table 3:
Reserved for future use
SW-1
OFF
SW-5 SW-6 SW-7 SW-8 Reserved for future use
OFF OFF OFF OFF Reserved
(Factory Default)
*
*
17

5.0 OPERATION

Once the CopperLink Ethernet Extenders are properly installed, they should operate transparently. No user settings required. This section describes reading the LED status monitors.

5.1 POWER UP

Before applying power to the CopperLink Ethernet Extender, please review section 3.5, “Connecting Power” on page 15 to verify that the unit
is connected to the appropriate power source.
There are no user-serviceable parts in the CopperLink Ethernet Extender. Fuse replacement should only be performed by quali­fied service personnel. Contact Patton Electronics Technical sup-
WARNING
port at (301) 975-1007 for more information.

5.2 FRONT PANEL LED STATUS MONITORS

The CopperLink Ethernet Extender features seven front panel LEDs (five on the rack card) that monitor power, the Ethernet signals, and the Cop­perLink connection. Figure 10 shows the front panel LEDs. Table 4 on page 19 describes the LED functions for the model.
Power
LED
Figure 10.
CopperLink™ Ethernet Extender
Fdx
CopperLink
Ethernet
Fdx LED
Ethernet
Collision LED
Ethernet
Link LED
CopperLink
QOL LED
CopperLink
Link LED
CopperLink Ethernet Extender unit front panel
18
Ethernet
100M LED
Table 4:
Front panel LED description for the 2168A
LED Description
Power
On (green)
when power is applied to the unit.
Off
when no power is applied to the unit.
CopperLink ­Link
On (green)
between the units is established.
when the end-to-end CopperLink link
Off
when the link
has not been established or when the link fails
CopperLink ­QOL
Flashes yellow
amount of error correction taking place on data pass-
at different rates to indicate the
ing over the CopperLink link. This is a normal operat­ing condition and all data is passing correctly over the link even if the link is
solidly yellow. However, if the LED is solid yellow and the CopperLink Link LED is Off, then there is too much noise on the line for an active link.
Ethernet - Link On (green) when the 10/100Base-T Ethernet link
has been established. Off when the 10/100Base-T Ethernet link has not been established or when the link fails. Flashes when there is Ethernet activity.
Ethernet - COL (Collision)
Ethernet - FDX (Duplex)
Flashes yellow to indicate Ethernet collisions are occurring.
On (yellow) when in full-duplex Ethernet mode. Off when when operating in half-duplex Ethernet mode.
Ethernet - 100M On (yellow) when the link has not been established
or when operating in 100-Mbps Ethernet mode. Off when operating in 10-Mbps Ethernet mode.
19
APPENDIX A
SPECIFICATIONS

A.1 LAN CONNECTION

• Unshielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet
• CopperLink Connection: — 2168A/TB45: RJ-45 and Terminal Block
— 2168A/2158A: RJ-45 only

A.2 TRANSMISSION LINE

Two-wire unconditioned twisted pair.

A.3 COPPERLINK LINE RATE

16.67 Mbps (Model 2168A and Model 2168A/TB45) and 12.55 Mbps
(Model 2158A) symmetric upstream/downstream. Additional symmetric and asymmetric rates are available via DIP switch settings:
• Model 2158A - Symmetric Line Rate: 12.5 Mbps
• Model 2168A and Model 2168A/TB45 - Symmetric Line Rates:
6.25 Mbps, 9.38 Mbps, 12.5 Mbps, 16.67 Mbps
• Model 2168A and Model 2168A/TB45 - Asymmetric Line Rates:
4.17 Mbps/1.56 Mbps, 9.38 Mbps/1.56 Mbps, 16.67 Mbps/2.34 Mbps

A.4 COPPERLINK DISTANCE

6,000 ft (1.83 km) at 1.56 Mbps upstream/4.17 Mbps downstream
Note Distances depend on selected line rate.

A.5 COPPERLINK SURGE SUPPRESSOR

Transient peak surge maximum current: 200A (8/20 μs).

A.6 LED STATUS INDICATORS

• Power (Green)
• CopperLink: Link (Green) & QOL (Yellow)
• Ethernet: Link (Green), Collision (Yellow), Duplex (Yellow), 10/100M
(Yellow)
20

A.7 POWER SUPPLY

Input power: 5 VDC, 1A
Power consumption: 560 mA at 5 VDC (typical)
External AC and DC options:
• AC: 120 VAC, 220 VAC, and UI (120–240 VAC)
• DC: 12 VDC, 24 VDC and 48 VDC
Internal 36-72VDC (nominal 48V) Terminal Block Plug (1x3, 3.81mm, with screws) Pin Header Socket Connector

A.8 TEMPERATURE RANGE

32–122°F (0–50°C)

A.9 HUMIDITY

Up to 90% non-condensing.

A.10 DIMENSIONS

1.58H x 4.16W x 3.75D in. (10.6H x 4.1W x 8.8D cm)
21
APPENDIX B
MODEL 2168A AND 2158A SERIES FACTORY REPLACEMENT PARTS AND ACCESSORIES
Patton Model # Description
Base Models
2168A/L/EUI Local Multi Rate CopperLink Ethernet Extender with RJ-45 connec-
tor, 120-240VAC
2168A/R/EUI Remote Multi Rate CopperLink Ethernet Extender with RJ-45 con-
nector, 120-240VAC
2168A/L/TB45/EUI Local Multi Rate CopperLink Ethernet Extender with terminal block,
120-240VAC
2168A/R/TB45/EUI Remote Multi Rate CopperLink Ethernet Extender with terminal
block, 120-240VAC
2168A/TB45/EUI­2PK
2158A/L/EUI Local Fixed Rate CopperLink Ethernet Extender with RJ-45 connec-
2158A/R/EUI Remote Fixed Rate CopperLink Ethernet Extender with RJ-45 con-
2158A/L/TB45/EUI Local Fixed Rate CopperLink Ethernet Extender with terminal block
2158A/R/TB45/EUI Remote Fixed Rate CopperLink Ethernet Extender with terminal
2158A/EUI-2PK Fixed Rate CopperLink Ethernet Extender Kit: includes one local (L)
2168A/L/E Local Multi Rate CopperLink Ethernet Extender with RJ-45 connec-
2168A/R/E Remote Multi Rate CopperLink Ethernet Extender with RJ-45 con-
2168A/L/TB45/E Local Multi Rate CopperLink Ethernet Extender with terminal block 2168A/R/TB45/E Remote Multi Rate CopperLink Ethernet Extender with terminal
2168A/TB45/E­2PK
2158A/L/E Local Fixed Rate CopperLink Ethernet Extender with RJ-45 connec-
2158A/R/E Remote Fixed Rate CopperLink Ethernet Extender with RJ-45 con-
2158A/L/TB45/E Local Fixed Rate CopperLink Ethernet Extender with terminal block
2158A/R/TB45/E Remote Fixed Rate CopperLink Ethernet Extender with terminal
Multi Rate CopperLink Ethernet Extender Kit: includes one local (L) and one remote (R) CopperLink Ethernet Extender, 120-240VAC
tor, 120-240VAC
nector, 120-240VAC
and RJ45, 120-240VAC
block and RJ45, 120-240VAC
and one remote (R) CopperLink Ethernet Extender; with terminal block and RJ45; 120-240VAC
tor
nector
block Multi Rate CopperLink Ethernet Extender Kit: includes one local (L)
and one remote (R) CopperLink Ethernet Extender
tor
nector
and RJ45
block and RJ45
22
Patton Model # Description
2158A/EI-2PK Fixed Rate CopperLink Ethernet Extender Kit: includes one local (L)
and one remote (R) CopperLink Ethernet Extender; with terminal block and RJ45
07M2168A-UM
User Manual
Power Supplies
08055DCUI 08055-120-5-1
12V-PSM 12 VDC Input Adapter 24V-PSM 24 VDC Input Adapter 48V-PSM 48 VDC Input Adapter
100-240VAC (+5V reg. DC/2A) Universal Input Adapter. 120 VAC (+5V reg. DC/1A) Input Adapter
Power Cords (Only required with optional UI power supply (08055DCUI)
0805US American Power Cord 0805EUR European Power Cord CEE 7 0805UK United Kingdom Power Cord 0805AUS Australian Power Cord 0805DEN Denmark Power Cord 0805FR France/Belgium Power Cord 0805IN India Power Cord 0805IS Israel Power Cord 0805JAP Japan Power Cord 0805SW Switzerland Power Cord
23
APPENDIX C
COPPERLINK SERIES INTERFACE PIN ASSIGNMENT

C.1 10/100BASE-T INTERFACE

RJ-45

• Pin 1: TX+/RX+
• Pin 2: TX-/RX-
• Pin 3: RX+/TX+
• Pin 6: RX-/TX-
• Pins 4, 5, 7, 8: no connection

C.2 COPPERLINK INTERFACE

RJ-45

• Pin 4: RING
• Pin 5: TIP
• Pins 1, 2, 3, 6, 7, 8: no connection

Terminal Block

See Figure 4 on page 11.
24
APPENDIX D
DISTANCE CHART, BASED ON 24 AWG (0.5 MM)
Symm Line Rate Distance in feet (km)
6.25 Mbps 4,500 (1.37)
9.38 Mbps 4,150 (1.26)
*
12.5 Mbps
16.67 Mbps 3,300 (1.00)
4,000 (1.22)
*. This is the only option available for Model
2158A.
Asymm Line Rate (DS/US) Distance in feet (km)
4.17 Mbps/1.56 Mbps (Mode 0) 6,000 (1.83)
9.38 Mbps/1.56 Mbps 5,500 (1.68)
16.67 Mbps/2.34 Mbps 5,000 (1.52)
Note DS = downstream from L unit to R unit
US = upstream from R unit to L unit
25
NOTES
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
26
NOTES
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
27
NOTES
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
Copyright © 2008
Patton Electronics Company
All Rights Reserved.
28
Loading...