Patton 1206PRC USER MANUAL

MODEM ELIMINATOR, X.21
Doc #: 118001UA
Part #: 07M1206P-A
1206P
(CTS ME-X.21)
INSTALLATION AND OPERATIONS MANUAL
An ISO-9001
Copyright© 2000 Patton Electronics Co., All Rights Reserved
PATTON ELECTRONICS CO.
1206P INSTALLATION AND OPERATIONS MANUAL
118001UA
COPYRIGHT NOTICE
Copyright© 2000 Patton Electronics Co., All Rights Reserved.
PROPRIET AR Y NOTICE
The information contained herein is proprietary and confidential to Patton Electronics Co. Any reproduction or redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization is given by Patton Electronics Co.
WARRANTY NOTICE
WARRANTIES: Patton Electronics Co. (hereafter referred to as Patton) warrants that its equipment is free from any defects in materials and workmanship. The warranty period shall be two years from the date of shipment of equipment. Patton’s sole obligation under its warranty is limited to the repair or replacement of the defective equipment, provided it is returned to Patton, transportation prepaid, within a reasonable period. This warranty will not extend to equipment subjected to accident, misuse, alterations or repair not made by Patton or authorized by Patton in writing.
PUBLICATION NOTICE
This manual has been compiled and checked for accuracy. The information in this manual does not constitute a warranty of performance. Patton reserves the right to revise this publication and make changes from time to time in the content thereof. Patton assumes no liability for losses incurred as a result of out-of-date or incorrect information contained in this manual.
i
PATTON ELECTRONICS CO.
118001UA
INSTALLATION AND OPERATIONS MANUAL1206P
EMISSION REQUIREMENTS
FCC CLASS A
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expence.
CANADIAN EMISSIONS
This digital apparatus does not exceed the Class A limits for noise emmissions from a digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le present appareil numerique n’emet pas de bruits redioelectriques depassant les limites applicables aux appareils numeriques de la Class A prescites dans le Reglement sur le brouillage redioelectrique edicte par le ministere des Communications du Canada.
ii
PATTON ELECTRONICS CO.
1206P INSTALLATION AND OPERATIONS MANUAL
118001UA
TABLE OF CONTENTS
CHAPTER 1 - OPERATION
Clocking ........................................................................................................................... 1-1
Delaying INDICATE .......................................................................................................... 1-1
Power .............................................................................................................................. 1-1
Approvals......................................................................................................................... 1-2
Available Options............................................................................................................. 1-2
CHAPTER 2 - SETUP AND INSTALLATION
Power Connection .......................................................................................................... 2-1
Factory Configuration Switch Settings.......................................................................... 2-1
Disassembly .................................................................................................................... 2-2
Installation ....................................................................................................................... 2-2
Equipment Grounding (JP4)........................................................................................... 2-2
IND Delay, Port 1 (SW2-1,2)........................................................................................ 2-2
IND Delay, Port 2 (SW2-4,5)........................................................................................ 2-2
Internal Baud Rate Selection (SW1-1,2,3,4) .............................................................. 2-3
High Speed Option Rates (JP7,JP8,JP9,JP10).......................................................... 2-3
Factory Test Jumpers (JP1).......................................................................................... 2-4
APPENDIX
DB-15 Connector Pins Used ......................................................................................... A-1
Signal Flow Diagram....................................................................................................... A-1
Strapping Guide .............................................................................................................. A-2
iii
PATTON ELECTRONICS CO.
1206P INSTALLATION AND OPERATIONS MANUAL
118001UA
CHAPTER 1 - OPERATION
The 1206P (CTS ME-X.21) is a cost effective solution for interconnection of X.21 terminal devices located in proximity of each other. The use of two modems is eliminated with a resulting cost savings to the user. The 1206P (CTS ME-X.21) complies with the CCITT V.11 balanced interface specification. Two 15 pin DB-15 connectors are provided to interface to the X.21 terminals.
Clocking
Clocking at rates up to 768Kbps with the low speed version and up to 2.048Mbps with High Speed Option are provided by the internal baud rate generator. The generator will provide clocks for both terminal and insure the data is synchronized with the S Clock in both directions.
Delaying INDICATE
Control (C) is looped back to Indicate (I) on each Port. To allow terminals requiring I delay to function properly, selectable delays of Constant, 0mS, 8mS and 50mS of C to I delay is provided. Each Port is individually configured for I delay.
Power
110 or 220 Volt operation is provided by a convenient switch located on the rear panel of the 1206P (CTS ME-X.21). Simply install the proper fuses (110VAC - .16ASB, 250V or 220VAC
- .8ASB, 250V) and power plug for the country of use and select the proper line voltage and the unit is ready for operation.
PWR TRC I S
1-1
INTERNATIONAL SERIES
1206P
OPERATION
PATTON ELECTRONICS CO.
118001UA
INSTALLATION AND OPERATIONS MANUAL1206P
Approvals
Safety approvals for UL, CSA & TÜV have been granted allowing the Modem Eliminator to be used virtually anywhere in the world. FCC Part 15 class A emissions approvals insure the Modem Eliminator will not interfere with any of the other equipment in your data center.
CE NOTICE: The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low V oltage Directive (L VD) of the Union European (EU). A Certificate of Compliance is available by contacting T echnical Support.
Available Options
1206P (CTS ME-X.21) is available in both stand-alone subset or rack-mountable versions (1206PRC). Various configuration of the interface are also available from the factory. The 1206PRC fits into the Model 1010R16 16 Card Rack Assembly.
OPERATION
1-2
PATTON ELECTRONICS CO.
1206P INSTALLATION AND OPERATIONS MANUAL
118001UA
Caution, Disconnect the POWER Before Removing The Cover Vorsicht, Befor Deckung Abnehmen Mach Strom Zu.
CHAPTER 2 - SETUP AND INSTALLATION
Power Connection
Before connecting the 1206P (CTS ME-X.21) to a AC power source the top cover must be installed and secured with the supplied #8-32 screws. The unit is supplied with a 110/220VA voltage switch, turn the switch with a coin or screw driver to the appropriate voltage for your country. EXAMPLE: In the United States of America; set to 110VA. The unit is supplied with a IEC power connector next to the voltage select switch, plug the power cord into the connector until it is firmly seated. You may now connect the power cord into your AC outlet.
110
220
100-120V
0.16ASB,250V TO.16A,250V
200-240V
0.08ASB,250V
TO 0.08A,250V
110 / 220 VA Switc h
Fuse Drawer
CAUTION
FIRE, REPLACE ONLY WITH SAME TYPE AND RATING FUSE.
IEC Pow er Connector
*
: FOR CONTINUED PROTECTION AGAINST RISK
PORT 1
Factory Configuration Switch Settings
* Switch fuse for 100-120V (.16ASB, 250V) or 200-240V
(.8ASB, 250V) as noted on rear of unit.
The 1206P (CTS ME-X.21) is configured prior to shipment with the switches set to the following default positions:
Switch 1 - 2, 3, 5 and 6 to OFF, 1 and 4 to ON. Baud Rate = 64Kbps
Switch 2 - 1, 3, 4 and 6 to OFF, 2, and 5 to ON. Port 1 IND Delay = 0
Port 2 IND Delay = 0
JP1 - JP3 always connected JP4 - Open
HS Option
JP7 - Open JP8 - Open JP9 - Open JP10 - Open
If the system application requires one of more of the default settings to be changed, it will be necessary to remove the top cover of the enclosure to access and change the DIP switches or Jumpers located on the printed circuit board.
2-1
SETUP & INSTALLATION
PATTON ELECTRONICS CO.
118001UA
INSTALLATION AND OPERATIONS MANUAL1206P
Disassembly
Remove the top cover by unscrewing the phillips head screws located on the left and right sides of the 1206P (CTS ME-X.21). The configuration switches and Jumpers are located on the PCB as indicated on the strapping guide in the Appendix of this manual. After the switch selection activity is completed,
re-install the top cover BEFORE connecting to an AC
power source.
Installation
Select an appropriate location accessible to and within six feet of an AC power outlet. The outlet must have a ground pin receptacle for product warranty.
"Straight Through"
shielded cables, terminated in male X.21 (DB-15) connectors should be used to connect the two terminals to the 1206P (CTS ME-X.21). Set the switches and Jumpers to match the required configuration using the descriptions in this chapter and the strapping guide in the appendix.
Equipment Grounding (JP4)
JP4 provides for grounding interconnection in those systems requiring a connection between (Frame Ground) and (Signal Ground). Connect ONLY if required.
IND Delay, Port 1 (SW2-1,2)
SW2 position 1 and 2 selects C to I delay for the terminal connected to PORT 1. C (pins 3,10) from PORT 1 is looped back to I (pins 5,12) through the delay circuitry.
SW2-1 SW2-2 DELAY
ON ON Const
OFF ON 0mS
ON OFF 8mS
OFF OFF 50mS
IND Delay, Port 2 (SW2-4,5)
SW2 position 4 and 5 selects C to I delay for the terminal connected to PORT 2. C (pins 3,10) from PORT 2 is looped back to I (pins 5,12) through the delay circuitry.
SW2-4 SW2-5 DELAY
ON ON Const
OFF ON 0mS
ON OFF 8mS
OFF OFF 50mS
Internal Baud Rate Selection (SW1-1,2,3,4)
S
ETUP & INSTALLATION
2-2
PATTON ELECTRONICS CO.
1206P INSTALLATION AND OPERATIONS MANUAL
118001UA
Selection of internal rates is provided by configuration of SW1 positions 1 through 4 and JP7 through JP10 if the High Speed Option has been installed by the factory. The following table shows the rates available:
SW1-1 SW1-2 SW1-3 SW1-4 RATE
ON ON ON ON HS Opt
OFF ON ON ON 768K
ON OFF ON ON 384K
OFF OFF ON ON 192K
ON ON OFF ON 128K
OFF ON OFF ON 72K
ON OFF OFF ON 64K*
OFF OFF OFF ON 57.6K
ON ON ON OFF 56K
OFF ON ON OFF 48K
ON OFF ON OFF 38.4K
OFF OFF ON OFF 28.8K
ON ON OFF OFF 19.2K
OFF ON OFF OFF 14.4K
ON OFF OFF OFF 9.6K
OFF OFF OFF OFF 4.8K
High Speed Option Rates (JP7,JP8,JP9,JP10)
If the high speed option is installed the following rates can be utilized by setting SW1 positions 1 through 4 to ON:
JP10 Installed JP7, JP8 & JP9 Removed - 256K JP9 Installed JP7, JP8 & JP10 Removed - 512K JP8 Installed JP7, JP9 & JP10 Removed - 1.024M JP7 Installed JP8, JP9 & JP10 Removed - 2.048M
Factory Test Jumper (JP1)
2-3
SETUP & INSTALLATION
PATTON ELECTRONICS CO.
118001UA
INSTALLATION AND OPERATIONS MANUAL1206P
The factory test jumper must be installed for the Modem eliminator to properly function. Insure this jumper is installed prior to operation of the unit.
S
ETUP & INSTALLATION
2-4
PATTON ELECTRONICS CO.
APPENDIX
T echnical Specifications
1206P INSTALLATION AND OPERATIONS MANUAL
118001UA
Application
Interconnect two X.21 terminal type devices
Capacity
Two X.21 Sync or Async Terminals
Data Format
Data is Transparent
1 - Frame Gnd
8 - Sign al Gn d
(3,10) - Control
(5,12) - Indicate
(2,9) - Tr ans
Data Rates
4.8K, 9.6K, 14.4K, 19.2K,
28.8K, 38.4K. 48K, 56K,
57.6K, 64K, 72K, 128K, 192K, 384K & 768Kbps (256K, 512K, 1024K & 2048K with High Speed Option)
Timing
Internal Baud Rate Generator
Front Panel
Indicators: ...Power, T, R, C,
Port 2Port 1
Frame Gnd - 1 Signal Gnd - 8
Control - (3 ,10 ) Indicate - (5,12)
Trans - (2,9)
I, S
Channel Interface
Two CCITT X.21(V.11) female connectors (DB-15)
Power Source
100-120/200-240VAC, 50 to 60Hz, 0.16/0.08A switchable
Environmental
Oper Temp: ... 32° to 122°F
(0° to 50°C)
Rel Humidity:.. 5 to 90% non-
condensing
Altitude: .......... 0 to 10,000
feet
Dimensions
Height:...... 1.75 inches (4.44
cm)
Width: ...... 8.90 inches (22.60
cm)
Length:..... 10.00 inches
(25.40 cm)
(4,11) - Receive
(6,13) - Sig Timing
Transm it( B) (from DTE)
Control(B ) (from DTE)
Receive(B ) (from DCE)
Indication(B) (from DCE)
Signal Timing(B ) (from DCE)
CLOCK
GENERATOR
Signal Flow Diagram
DB-15 Connector Pins Used
Receive - (4,11)
Sig Timing - (6,13)
9
10
11
12 13 14
15
A-1
Shield (com m on)
1
2
Transm it( A ) (from DTE)
3
Cont rol(A ) (fro m DTE) Receive(A ) (from DCE)
4 5
Indication(A ) (from DCE)
6
Signal Timing(A) (fro m DCE)
7
8
GND (com m on)
APPENDIX
INSTALLATION AND OPERATIONS MANUAL1206P
SW1
Power T R C I S
123456
ONOFF
Not Used Not Used
Install Only One Jumper to
Select the Required R a te
2 .048Mbps HS Opti on
1 .024Mbps HS Opti on
512Kbps HS Option
256Kbps HS Option
HS VERSION
ONLY ON THE OPTIONAL
JP9
JP8
JP10
Baud Rate Select
JP7
Ch 1 IND Delay SW2
2
1
ON
OFF
ON
OFF
Ch 2 IND Delay SW2
4
ON
OFF
ON
OFF
ON.
ON OFF OFF
5
ON.
ON OFF OFF
Delay Constant 0 mS 8 mS 50mS
Delay Constant 0 mS 8 mS 50mS
Baud Rate Select SW1
2
1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON OFF OFF
ON
ON OFF OFF
ON
ON OFF OFF
ON
ON OFF OFF
3 ON ON ON ON
OFF OFF OFF OFF
ON ON ON ON
OFF OFF OFF OFF
4 ON ON ON ON ON ON ON ON
OFF OFF OFF OFF OFF OFF OFF OFF
Speed HS Option 768K 384K 192K 128K 72K 64K
57.6K 56K 48K
38.4K
28.8K
19.2K
14.4K
9.6K
4.8K
JP4
CGN D
TO
DGN D
A-2
Chan 1 Chan 2
PATTON ELECTRONICS, INC.
118001UA
SW2
123456
Ch1 IND Delay Select
Not Used
Ch2 IND Delay Select
Not Used
ONOFF
JP1
Factory Test Strap Must be Installed For Prop er Operation
APPENDIX