Patton 1058DV, 1058DVRC User Manual

1
GGoCardoCard
Model 1058DV
Product Model 1058 Standalone and Rack Card Product Name VDSL Modem Product Manager John Grant Contact Jgrant@patton.com
Who are the customers for the Model 1058?
The Patton Model 1058DV enables the utilization of existing copper infrastructure for the delivery of symmetrical broadband and POTS/ISDN services over a single twisted pair of voice-grade wire. The Model 1058DV solution is targeted to any user or provider who needs high-speed data links. These organizations include but are not limited to CLEC’s, ISP’s, Educational Facilities (Campus), MTU/MDU’s, and corporate/government offices. Popular applications for symmetrical VDSL include medical imaging, always on high-speed Internet access, and real time bi-directional video streaming.
and
1058DVRC
Typical applications include:
LAN-to-LAN Bridging: The Model 1058 connects remote LANs over a high-speed, symmetrical
12.5Mbps line. The 1058 CP is placed at a remote location and a 1058 CO is placed at the central site to provide a LAN-to-LAN connection over a voice-grade wire.
Ethernet Extension: Enables the customer to overcome the 328 ft (100m) limitations of Ethernet with a symmetrical 12.5 Mbps link at distances up to 4,656 ft (1.42 km).
Dedicated Internet and Voice Services: VDSL enables ISP’s to deliver dedicated high-speed Internet access and voice services from a Point-of-Presence (POP) to a customer premise. A 1058CO is used at the POP and a 1058CP is used at the customer premise. The Model 1058DV’s built-in POTS/ISDN splitter allows users to simultaneously use the phone or fax machine, while surfing the web, downloading files or receiving e-mails.
MTU/MDU Services: Using broadband VDSL, data and voice services can be extended to the hotel guest, apartment resident, and housing resident, etc. Patton’s VDSL modems allow service providers to avoid the cost and trouble of wiring the individual hotel rooms with 4-wire twisted pair or Ethernet cabling by using the existing voice-grade 2-wire infrastructure. The service provider would place the 1001R rack system with multiple 1058RCDV/CO rack cards in the basement or closet and the standalone 1058DV/CP in the individual hotel rooms. Once connected, the Model 1058’s will automatically establish a high-speed Point-to-Point voice and data link.
2
GGooCCardard
Model 1095 and 1095RC (Quick Connect)
Model 1088 (Rocket)
Related Patton xDSL Products:
Patton provides a complete line of xDSL products. Whether it’s VDSL for ultra-high speed connections, mSDSL for high-speed long distance connections, or iDSL for standard U-interface connections over long distances, Patton has the solutions to fit all types of networks. Patton's xDSL solutions include compact cross connects, rack-card based solutions, and CPE units for your last mile networking needs. Patton’s complete line of high-speed xDSL modems, include interfaces for 10Base-T Ethernet, T1/E1, G.703/G.704, voice, and serial (X.21, V.35, EIA-530, and V.24).
DSL Type
iDSL 128 Kbps 1092A 1082 1092ARC 3092/3192
HDSL 1.152 Mbps 1094A 1089 1094ARC 3095
mSDSL 2.034 Mbps 1095 1088 1095RC 3095
VDSL 12.5 Mbps - 1058 1058RC -
Max Data
Rate
Quick
Connect
Model 1058 Features and Benefits
High-Speed Symmetrical 12.5Mbps communications link.
Compact (Rocket)
Fast and reliable data transmission.
Rack Card Cross Connect
Model 3095 (Cross Connect)
Extends Ethernet beyond its current 328 ft (100m) limitation.
Built-in POTS/ISDN Splitter (1058DV only) Provides “life-line” telephone link. Full service integration (voice, video, and
data) services over existing voice-grade telephone wire.
Operation transparent to high-layer protocols.
Auto-sensing 10 or 100Base-T and full or half-duplex Ethernet.
Five status LEDs. Monitoring your connection and operational
Inexpensively links remote devices or extends LANs up to 4,652 ft (1,418 m).
Eliminates the need to install new LAN­grade cable or expensive fiber.
Lets higher-layer broadcast, multi-cast, and data frames pass through. Supports VLAN tagged frames.
No configuration necessary, just Plug & Play.
status is made simple.
3
GGooCCardard
Primary Application: Service Integration and LAN Extension
Used in pairs (Central Office and Customer Premise), the Model 1058 establishes a high­speed, line sharing, symmetrical 12.5 Mbps voice and data link. The Model 1058 inter­connects two geographically separated LANs over a voice-grade twisted pair wire. Operation is simple: packets destined for the remote LAN are sent transparently, at full line rate, to the peered LAN. The Model 1058DVs built-in splitter allows users to simultaneously talk on the phone while surfing the web, downloading files or receiving e­mails.
Optional parts for the Model 1058D and the Model 1058DV
DC Power Supplies
Rack cards are compatible with Patton’s Model 1001R High-Density Telco Rack System.
Optional DC Power Supplies for Standalone Units Part
Description
Number
48V-PSM -48 VDC power supply, 5VDC, 1A (optional) 24V-PSM -24 VDC power supply, 5VDC, 1A (optional) 12V-PSM -12 VDC power supply, 5VDC, 1A (optional)
4
GGooCCardard
Shipping/Export Information
ECCN export number: 8517.50.1000 Country of origin: United States of America, NAFTA Total weight boxed: .96lbs (.44kg) without power supply Individual unit: .4lbs (.18kg); without power supply
MTBF/ Repair Information
MTBF: 126,000 Hrs. Calculation based on MIL-HDBK-217F, Notice 2 - "Parts Count Reliability
Prediction"
Mean time to repair: 7–10 days Warranty: 1-year parts and labor Out of warranty repair rate: $150, flat rate – contact Patton’s Tech Support for details.
Physical Specifications
Dimensions: Standalone: 1.5” H x 4.13” W x 3.75” D (3.81 H x 10.5 W x 9.53 D cm) Rack Card: 3.00” H x 0.83” W x 7.84” D (7.6 H x 2.1 W x 19.9 D cm) Color: Standalone: Case: Black Front and Back Panel: Black with white letters
Rack Card: Front and Back Panel: White with black letters
Case material: Standalone: Plastic, Fire retardant
Rack Card: Iridite Aluminum
Environmental
Operating Temp: 32 to 122°F (0 to 50°C) Storage Temp: -40 to 185°F (-40 to +85°C) Relative Humidity: Up to 90% RH, non-condensing Altitude: 0 –15,000 feet (3,048 meters) Ventilation requirements: None, units do not require cooling fans.
5
GGooCCardard
Approvals Safety Emissions Telecommunications
FCC part 15, Class A FCC Part 68 A & B (1058DV only) CE Marked per EMC directive 89/336/EEC and low voltage directive 72/23/EEC.
ESD EN61000-4-2
EN55022 Class A,
conducted and radiated
emissions
Power Supplies
Standalone Units Only
AC: 120VAC, 50-60Hz, external or Universal input, 100-240VAC, 50-60Hz, external DC: -48VDC, -24VDC, or -12VDC external (optional)
6
GGooCCardard
Ordering Information- 1058D (Data Only) Model Description
1058D/CO Central Office VDSL Modem, Data Only; RJ-45 and Terminal Block; No
Power Supply
1058D/CP Customer Premise VDSL Modem, Data Only; RJ-45 and Terminal Block;
No Power Supply
1058D/CO/120 Central Office VDSL Modem, Data Only; RJ-45 and Terminal Block;
120VAC
1058D/CP/120 Customer Premise VDSL Modem, Data Only; RJ-45 and Terminal Block;
120VAC
1058D/CO/UI* Central Office VDSL Modem, Data Only; RJ-45 and Terminal Block; (UI)
100-240VAC
1058D/CP/UI* Customer Premise VDSL Modem, Data Only; RJ-45 and Terminal Block;
(UI) 100-240VAC
1058D-2PK VDSL Modem Set, Data Only; (Central Office and Customer Premise
1058D/120-2PK VDSL Modem Set, Data Only; (Central Office and Customer Premise
1058D/UI-2PK* VDSL Modem Set, Data Only; (Central Office and Customer Premise
1058DRC/CO Central Office VDSL Modem Rack Card, Data Only; RJ-45 and Terminal
1058DRC/CP Customer Premise VDSL Modem Rack Card, Data Only; RJ-45 and Terminal
When ordering standalone units, it is recommended that the 1058D be ordered in sets: one 1058D/CO (Local) and one 1058D/CP (Remote).
* =You must specify a country specific power cord
Unit); No Power Supply
Unit); 120VAC
Unit); (UI) 100-240VAC
Available Soon – Call for availability
Block
Block
7
GGooCCardard
Ordering Information- 1058DV (Data and Voice) Model Description
1058DV/CO Central Office VDSL Modem, Data and Voice; RJ-45 and Terminal
Block; No Power Supply
1058DV/CP Customer Premise VDSL Modem, Data and Voice; RJ-45 and Terminal
Block; No Power Supply
1058DV/CO/120 Central Office VDSL Modem, Data and Voice; RJ-45 and Terminal
Block; 120VAC
1058DV/CP/120 Customer Premise VDSL Modem, Data and Voice; RJ-45 and Terminal
Block; 120VAC
1058DV/CO/UI* Central Office VDSL Modem, Data and Voice; RJ-45 and Terminal
Block; (UI) 100-240VAC
1058DV/CP/UI* Customer Premise VDSL Modem, Data and Voice; RJ-45 and Terminal
Block; (UI) 100-240VAC
1058DV-2PK VDSL Modem Set, Data and Voice; (Central Office and Customer
Premise Unit); No Power Supply
1058DV/120-2PK
1058DV/UI-2PK* VDSL Modem Set, Data and Voice; (Central Office and Customer
1058DVRC/CO Central Office VDSL Modem Rack Card, Data and Voice; RJ-45 and
1058DVRC/CP Customer Premise VDSL Modem Rack Card, Data and Voice; RJ-45 and
When ordering standalone units, it is recommended that the 1058D be ordered in sets: one 1058DV/CO (Local) and one 1058DV/CP (Remote).
* =You must specify a country specific power cord
VDSL Modem Set, Data and Voice; (Central Office and Customer Premise Unit); 120VAC
Premise Unit); (UI) 100-240VAC
Available Soon – Call for availability
Terminal Block
Terminal Block
Loading...