defects, and will—at our option—repair or replace the product should it
fail within one year from the first date of shipment.
This warranty is limited to defects in workmanship or materials, and does
not cover customer damage, abuse or unauthorized modification. If this
product fails or does not perform as warranted, your sole recourse shall
be repair or replacement as described above. Under no condition shall
Patton Electronics
product. These damages include, but are not limited to , the f ollo wing: lost
profits, lost savings and incidental or consequential damages arising
from the use of or inability to use this product.
cifically disclaims all other warranties, expressed or implied, and the
installation or use of this product shall be deemed an acceptance of
these terms by the user.
1.1 FCC INFORMATION
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to P art 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own
expense. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
warrants all Model 1053 components to be free from
be liable for any damages incurred b y the use of this
Patton Electronics
spe-
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected
1.2 CE NOTICE
The CE symbol on your Patton Electronics equipment indicates that it is in
compliance with the Electromagnetic Compatibility (EMC) directive and
the Low Voltage Directiv e (LVD) of the Union European (EU). A Certificate
of Compliance is available by contacting Patton Technical Support.
4
Conformity documents of all Patton products can be
viewed online at www.patton.com under the appropriate
product page.
Important
1.3 SERVICE
All warranty and non-warranty repairs must be returned freight prepaid
and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This
number may be obtained from Patton Electronics Technical Service at:
Tel:
(301) 975-1007
E-mail:
URL:
support@patton.com
www.patton.com
Note
Packages received without an RMA number will not be
accepted.
Patton Electronics’ technical staff is also available to answer any questions that might arise concerning the installation or use of your
Model 1053. Technical Service hours:
through
Friday
.
8AM
to
5PM EST, Monday
5
2.0 GENERAL INFORMATION
Thank you for your purchase of this
product has been thoroughly inspected and tested and is warranted for
One Year parts and labor. If any questions or problems arise during
installation or use of this product, please do not hesitate to contact
Patton Electronics Technical Support
2.1 FEATURES
• Synchronous data rates: 32, 56, 64, and 128 kbps
• Asynchronous data rates: 0–38.4, 57.6, 76.8, and 115.2 kbps
• Full duplex operation over a single twisted pair (2-wires)
• Point-to-point distances up to 5 miles (all data rates) on 24 AWG
twisted pair
• Multi-rate symmetric DSL
• RS-232 Interface
• Compatible with popular Models 1092A, 1082, and 1052
• Universal power options, 120 VAC and -48, -24, and -12 VDC availab le
• LED status indicators
• Small, convenient desktop unit
• CE marked
Patton Electronics
at
(301) 975-1007
product. This
.
2.2 DESCRIPTION
The Patton Model 1053 is a high speed, AC po wered short range modem
that is able to operate synchronously or asynchronously—full duplex—
over a single twisted pair. Supporting data rates up to 128 kbps (synchronous) or 115.2 kbps (asynchronous), the Model 1053 is capable of
point-to-point distances up to 5 miles (8 km) using 24 AWG wire. The
Model 1053 supports internal, external, or receive recovery clocking, and
asynchronous data rates may be configured locally using DIP switches.
The Model 1053/A provides an RS-232 interface on a DB-25 f emale connector. Line connection is made by an RJ-45 jack. Standard versions of
Model 1053 are powered by a 100–240 VAC (Universal) supply. The DC
power supply options support either -12, -24, or -48 VDC.
6
3.0 CONFIGURATION
The Model 1053 is equipped with 16 DIP switches that enable configuration of the unit for a wide variety of applications. This section describes
switch locations and explains the different configurations
3.1 CONFIGURING THE HARDWARE DIP SWITCHES
S1 and S2 each contain eight internal DIP switches (see Figure 1) that
are used for configuration reset purposes only. To access switch sets,
use a small flat blade screwdriver to open the Model 1053’s case as
shown in Figure 2 on page 8.
Figure 1.
DIP switches S1 and S2
To configure the DIP switches, use a small screwdriver and gently push
each switch to its proper setting. The ON and OFF positions are shown
in Figure 1.
7
Figure 2.
Opening the Model 1053 case
Figure 1 on page 7 shows the orientation of the DIP switches in the “ON”
and “OFF” positions.
Configuring DIP Switch S1
DIP switch S1 is where you configure the data rate, asynchronous or
synchronous data format, transmit clock source. The following table summarizes default positions of DIP switches S1-1 through S1-8. Detailed
descriptions of each switch follow the table.
Switches S1-1 and S1-2: Data Rate.
Use switches S1-1 and S1-2 to
configure the asynchronous or synchronous data rate of the Model 1053.
8
Each setting represents one synchronous data rate and one asynchronous data rate.
If the S2-1 switch is positioned in the OFF position, the 128 kbps
sync data rate/0–38.4 kbps async data rate option is selected.
Switch S1-3:
Must be set to the ON position (Reserved)
.
S1-3Setting
OnReserved
Switch S1-4:
Must be set to the ON position (Reserved).
S1-4Setting
OnReserved
Switch S1-5: Asynchronous/Sync Operation.
Use Switch S1-5 to
configure the Model 1053 for async/sync operation. For synchronous
data rates set switch S1-5 OFF. For asynchronous rates set switch
S1-5 ON.
S1-5Setting
OffSync
OnAsync
Switches S1-6 and S1-7: System Clock Mode.
Use Switches S1-6
and S1-7 to configure the 1053 for internal, or receive recover clock
mode.
S1-6S1-7Clock ModeDescription
OnOnInternal System clock generated internally
OffOnExternal (DTE)System clock derived from termi-
nal interface
OnOffReceive RecoverSystem clock derived from the
received line signal
OffOffHardware Reset
9
Important
A pair of Model 1053s communicate synchronously
across the twisted pair line connection. Therefore,
must set these switches whether your application is
async or sync
configure one Model 1053 for internal clock mode and the
other Model 1053 for receive recover clock mode.
. For Sync or Async applications, please
you
Switch S1-8:
Configuring DIP switch S2
DIP switches in S2 are reserved and must be set in the OFF position.
The following table summarizes default positions of DIP switches S2-1
through S2-8.
Must be set to the OFF position (Reserved).
S1-8Setting
OffReserved
10
4.0 INSTALLATION
Once the Model 1053 has been configured, it is ready to connect to the
twisted pair interface, the serial port, and the power source. This section
tells you how to make these connections.
Figure 3.
Model 1053 Rear Panel
4.1 CONNECTING THE TWISTED PAIR INTERFACE
The Model 1053 supports communication between two DTE devices at
distances to 5 miles (8 km) over 24 A WG (0.5 mm) twisted pair wire . Two
things are essential:
• These units work in pairs. Both units at the end of the twisted pair DSL
span must be set for the same DTE rate.
• To function properly, the Model 1053 needs one twisted pair of metallic
wire. This twisted pair must be unconditioned, dry, metallic wire,
between 19 (0.9 mm) and 26 AWG (0.4 mm) (the higher number
gauges will limit distance). Standard dial-up telephone circuits, or
leased circuits that run through signal equalization equipment, or standard, flat modular telephone type cable, are not acceptable. The RJ-45
connector on the Model 1053’s twisted pair interf ace is polarity insensi-
11
tive and is wired for a two-wire interface. The signal/pin relationships
are shown in Figure 4.
Figure 4.
Model 1053 twisted pair line interface
4.2 CONNECTING THE MODEL 1053/A (RS-232)
The Model 1053/A supports RS-232 serial port connections. This section
describes how to connect the serial ports to your RS-232 equipment.
Connecting the Model 1053/A (RS-232) to a DTE Device
The Model 1053/A provides an RS-232 DCE (data circuit terminating
equipment) interface on a DB-25 female connector. As a DCE, this interface is designed to connect to DTE equipment, such as a router. When
connecting the RS-232 interface of the Model 1053/A to your DTE
device, use an RS-232 straight-through cab le (see Figure 5). Appendix C
on page 18 describes pin assignments and signal sources for the Model
1053/A RS-232 interface. When purchasing or constructing an interface
cable, use the pin diagrams in Appendix C as a guide.
Figure 5.
Connecting the Model 1053/A to an RS-232 serial DTE
4.3 POWER CONNECTION
The Model 1053 (all versions) are available with Universal AC (100–240
VAC), 120 VAC, 230 VAC or -12, -24, or -48 VDC power options. This
section describes these options.
12
Universal AC Power (100–240 VAC)
The Model 1053 uses a 5VDC, 2A universal input 100–240VAC, power
supply (center pin is +5V). The universal input power supply has a male
IEC-320 power entry connector. This power supply connects to the
Model 1053 by means of a barrel jack on the rear panel. Many international power cords are available for the universal power supply (Refer to
Appendix B on page 17 for country-specific power cords. The Model
1053 powers up as soon as it is plugged into an AC outlet—there is no
power switch.The Universal AC supply is equipped with a male IEC-320.
DC Power
The optional -12, -24, or -48 VDC DC-to
-
DC adapter supplied with the
DC version of the Model 1053 plugs in a DC source (nominal -12, -24, or
-48 VDC) and plugs into the barrel power supply jack on the rear of the
1053. Refer to Figure 6 to make the proper connection.
Figure 6.
Connecting DC power to the 48V-PSM DC power supply
There are no user-serviceable parts in the power
supply section of the Model 1053. Fuse replacement
should only be performed by qualified service personnel. Contact Patton Electronics Technical support at +1 (301) 975-1007, via our web site at
WARNING
www.patton.com, or by E-mail at support@patton.com,
for more information.
13
5.0 OPERATION
Once the Model 1053 is properly configured and installed, it should operate transparently. This sections describes power-up, reading the LED
status monitors.
5.1 POWER-UP
Before applying power to the Model 1053, read section 4.3, “Power Connection” on page 12 to ensure that the unit is connected to the appropriate power source.
5.2 LED STATUS MONITORS
The Model 1053 features six side-panel LEDs (see Figure 7). Table 1
describes the function of each LED.
Figure 7.
Model 1053 side panel LEDs
Table 1:
LED descriptions
LEDDescription
TXD(Active: Green) When lit, indicates data transmission.
RXD(Active: Green) When lit, indicates data transmission.
LINK(Active: Green) When lit, indicates that the end-to-end DSL
framer link is up, signifying that the link across the DSL span
is active. The DSL Link LED is off when the link is down.
NS(Active: Yellow) When the No Signal LED is lit, it indicates
that the local Model 1053 is not connected with the remote
Model 1053
14
APPENDIX A
MODEL 1053 SPECIFICATIONS
A.1 TRANSMISSION FORMAT
Synchronous or asynchronous
A.2 TRANSMISSION LINE
Single unconditioned twisted pair
A.3 CONTROL SIGNALS
CD and RTS
A.4 CLOCKING
Internal, external, or receive recover
A.5 DISTANCE
Distance, max, all data rates:
• 10.1 miles (16.4km) on 19 AWG (0.9 mm) wire
• 7.2 miles (11.5 km) on 22 AWG (0.64 mm) wire
• 5.0 (8 km) on 24 AWG (0.5 mm) wire
• 3.4 (5.5 km) on 26 AWG (0.4 mm) wire
A.6 DATA RATES
• Synchronous: 32, 56, 64, and 128 kbps
• Asynchronous: 0–38.4, 57.6, 76.8, and 115.2 kbps
A.7 LED STATUS INDICATORS
TXD, RXD, Link, NS (no signal), ER (CRC error)
A.8 CONNECTORS
RJ-45 on DSL line side; DB-25 female on serial interface side