Pathway Connectivity 6822 Datasheet

Page 1
PATHPORT 2-PORT GATEWAY, eDIN
#6822
Job Name:
Date: Notes:
Catalog #:
Pathport 2-Port DMX/RDM gateway is a compact node for encoding, routing and decoding DMX512 data over a standard Ethernet network. In addition to DMX, the Pathport 2-Port supports RDM discovery and configuration data transport.
DIN-rail mountable for fast installation in existing cabinets, or also available as part of a complete ETL-listed assembly.
FEATURES
Two DMX512 ports - user configurable as input or output
E1.11 DMX512A and E1.20 Remote Device Management (RDM)
compliant
LED indicators for port direction, power, Ethernet link activity and
identify
Operates on 802.3af Power-over-Ethernet or on an 18-48V wide-
range DC input
Pluggable screw terminal connector block for power IN and OUT
Two sets of pluggable terminal blocks for all DMX512 connections
to support both shielded twisted pair and CAT5/6
Supports the following DMX/Ethernet protocols
Art-Net
E1.31 streaming ACN (sACN)
Pathport Protocol
Strand Shownet
Fully compatible with all Pathport gateways and eDIN interfaces
Configuration is set using Pathscape, a free download at www.
pathwayconnect.com
Soft patch allows mix-and-match of different protocols
Route DMX according to universe or channel-by-channel
Multiple sources may be merged and/or prioritized
Fully customize DMX output universes
SPECIFICATIONS
PoE-powered Class 1 device, 4W max power consumption
Auxiliary input voltage, 18-48V
60V protection on each port
10Mb TCP/IP connection
Operating Conditions: 14°F-118°F (-10°C to 48°C);
10-90% relative humidity, non-condensing
STANDARDS COMPLIANCE
ANSI E1.11 DMX512-A(2008)/USITT DMX512(1990)
ANSI E1.20 RDM(2010) - Remote Device Management
RoHS 2002/95/EC
Class 2 Low Voltage
WEIGHTS AND DIMENSIONS
0.4 lbs (0.18 kg)
4.5”W x 4”H x 1.9”D (113mm x 103mm x 48mm)
INCLUDED FURNISHINGS
DIN tray (housing) with end caps
11” (280mm) piece of DIN rail
Installation/Operations manual
#103 - 1439 17th Ave SE Calgary AB Canada T2G 1J9 Phone + 1 403 243 8110 orders@pathwayconnect.com www.pathwayconnect.com
© Acuity Brands Lighting Inc. All Rights Reserved Form #6822-100-REV1
1 of 3
02.07.2019
Page 2
Lighting Console
eDIN #1106 Typical
APPLICATION RISER
Standard Ethernet Layout
Intelligent Fixtures
E1.20 RDM Responders
LED Wash Lights
Dimmer Racks
Other DMX512 Controlled Equipment
DMX512
DMX512
DMX512
DMX512
AUX POWER IN 18 - 48VDC MAX 4 W
DMX - B OUTPUT
DMX - B INPUT
DMX - A OUTPUT
DMX - A INPUT
AUX POWER IN 18 - 48VDC MAX 4 W
DMX - B OUTPUT
DMX - B INPUT
DMX - A OUTPUT
DMX - A INPUT
V+
V-
EARTH GND
V-
V+
SHLD COM
D1-
D1+
NC
NC
SHLD COM
D1-
D1+
NC
NC
V+
V-
EARTH GND
V-
V+
SHLD COM
D1-
D1+
NC
NC
SHLD COM
D1-
D1+
NC
NC
POWER NET LINK / ACT
DMX PORT B
DMX PORT A
POWER NET LINK / ACT
DMX PORT B
DMX PORT A
IDENTIFY
IDENTIFY
#6822
Pathport 2-Port Gateway, eDIN
MANAGED GIGABIT
ETHERNET SWITCH
VIA
Ethernet Switch w/ PoE
LINK/ACT
PORT 1 PORT 2 PORT 3 PORT 4 PORT 5 PORT 6 PORT 7 PORT 8 PORT 9 PORT 10
Cat5/6 - Ethernet
POE
RDM Configuration Access Point
24VDC Power Supply
#1001-100-48-DIN Typical
DMX512
Lighting Console
NEMA Wall Cabinet eDIN #1105 Typical
#6822 Pathport 2-Port Gateway
V+
V-
EARTH GND
V-
V+
AUX POWER IN 18 - 48VDC MAX 4 W
DMX - B OUTPUT
DMX - B INPUT
SHLD COM
D1-
D1+
NC
NC
DMX - A OUTPUT
DMX - A INPUT
SHLD COM
D1-
D1+
NC
NC
V+
ENABLE
V-
GRD
EARTH
V-
V+
POWER IN
9-30VDC
6W MAX
DMX512
ISO INPUT PWR
SHLD COM
D1-
D1+
D2-
DMX THRU
D2+
SHLD COM
D1-
D1+
DMX IN
D2-
D2+
NCC DMX512-A ISOLATED INPUT ISOLATED OUTPUT
#1009 DMX/RDM Splitter 4-way
NEMA Wall Cabinet
POWER NET LINK / ACT
DMX PORT B
DMX PORT A
RDM
DISABLE
4 - PORT DMX/RDM SPLITTER
POWER
RDM A RDM B RDM C RDM D
DMX/RDM
PROCESSOR
ISO PWR A ISO PWR B ISO PWR C ISO PWR D
IDENTIFY
Ethernet-enabled
Computer for configuration
Rev.1
Intelligent Fixtures
D2+
D2-
D1+
D1-
COM SHLD
D2+
D2-
D1+
D1-
COM SHLD
D2+
D2-
D1+
D1-
COM SHLD
D2+
D2-
D1+
D1-
DMX OUT A DMX OUT B DMX OUT C DMX OUT D
COM SHLD
DMX512
E1.20 RDM Responders
DMX512
LED Wash Lights
#103 - 1439 17th Ave SE Calgary AB Canada T2G 1J9 Phone + 1 403 243 8110 orders@pathwayconnect.com www.pathwayconnect.com
© Acuity Brands Lighting Inc. All Rights Reserved Form #6822-100-REV1
2 of 3
02.07.2019
Page 3
Fastening mechanism designed
for 35 x 7.5mm DIN rail
[49mm]
DMX512 INPUTS/OUTPUTS (2)
DIMENSIONS
#6822
Pathport 2-Port Gateway, eDIN
NCNCD1+
DMX PORT A
IDENTIFY
DMX PIN OUTS
XLR PIN # PURPOSE
DMX512/RDM
PINOUT:
FOR SHIELDED
TWISTED PAIR
LED INDICATORS
18 - 48VDC MAX 4 W
DMX - A INPUT
DMX - A OUTPUT
COM
SHLD
D1-
NCNCD1+
DMX PORT B
4.5”
[113mm]
D1-
Ethernet Connector
DMX - B INPUT
COM
SHLD
Female RJ45
AUX POWER IN
DMX - B OUTPUT
POWER NET LINK / ACT
1 Shield
2 Data - (complement)
3 Data + (true)
4 Not Used
5 Not Used
POWER IN (If PoE not in use): 18-48VDC, 4W Supply required. Use #1001-100-48-DIN PSU or equal.
V+
V-
GND
EARTH
V-
V+
4”
[103mm]
1.9”
XLR PIN # CAT5/6 Pin # and Color PURPOSE
3 1 - White/Orange Data 1 + (true)
DMX512/RDM
PINOUT:
FOR CAT 5/6
2 2 - Orange Data 1 - (complement)
5 3 - White/Green Not Used
4 6 - Green Not Used
- 4 - Blue Not Used - do not connect
- 5 - White/Blue Not Used - do not connect
1 7 - White/Brown Shield/COM
1 8 - Brown Shield/COM
PART # DESCRIPTION
6822 Pathport 2-Port Gateway, eDIN
ACCESSORIES
1001-100-48-DIN 100 Watt, 48VDC Power Supply, DIN-Mountable
1103 Rack-mount Panel Kit (2RU) with two 16.5” (420mm) sections of DIN rail
1105 Small eDIN Enclosure (NEMA1) with 9.5” (240mm) of vertical DIN rail
1106 Large eDIN Enclosure (NEMA1) with 19.5” (495mm) of vertical DIN rail
1107 Large eDIN Enclosure (NEMA1) with three rows of 9.5” (240mm) horizontal DIN rail
1108 eDIN System Enclosure, 10” x 13” x 4.5” c/w Two 9” Horizontal DIN Rail
1109
4000 eDIN Enclosure Assembly Service
#103 - 1439 17th Ave SE Calgary AB Canada T2G 1J9 Phone + 1 403 243 8110 orders@pathwayconnect.com www.pathwayconnect.com
Expanded eDIN System Enclosure 18.5” x 31.5” x 6.5” c/w Three 24”Vertical DIN Rail, One 18” DIN Rail in Class 1 section, two 3-gang knockouts in removable door
© Acuity Brands Lighting Inc. All Rights Reserved Form #6822-100-REV1
02.07.2019
3 of 3
Loading...