Job
Catalog #:
EDIN 4-WAY DMX512/RDM OPTO-SPLITTER
#1009
Date:
Notes:
PRODUCT OVERVIEW SPECIFICATIONS
The eDIN #1009 is a DIN-rail mountable four-way optosplitter that supports the bi-directional communication standard E1.20 Remote Device Management (“RDM”), as well as
DMX512. Used in installations that require ‘star’ wiring configurations, all output ports are separate electrical entities,
fully opto-isolated and independently protected against fault
voltages.
FEATURES
• One DMX512 input
• Four fully isolated DMX512/RDM bi-directional output ports
• One active DMX512/RDM bi-directional thru port
• Pluggable screw terminal connector block for power IN
and OUT
• Two sets of pluggable terminal blocks for all DMX512/RDM
connections to support both shielded twisted pair and
CAT5/6
• Power and data easily daisy-chained between modules
• DMX IN indicator
• DC power input indicator
• ISO 5V indicator
• Auto-termination of DMX THRU
• No fuses - self-resetting port protection recovers from
voltage faults
• 1500V opto-isolation between input and output ports
• 250V fault protection on input and output ports
• Input operating voltage: 9-30 VDC
• 6W power consumption
• Operating conditions: -10 to + 50°C; 10-90% relative
humidity, non-condensing
STANDARDS COMPLIANCE
• ANSI E1.11 DMX512-A(2008)/USITT DMX512(1990)
• ANSI E1.20 RDM(2010) - Remote Device Management
• CE/FCC
• RoHS 2002/95/EC
• Class 2 Low Voltage
WEIGHTS AND DIMENSIONS
• 0.70 lbs (0.316 kg)
• 3.6”W x 6.25”L x 1.5”H (91mm x 160mm x 38mm)
INCLUDED FURNISHINGS
• DIN tray (housing) with end caps
• 12” (300mm) x 35mm DIN rail
• Installation/Operations manual
#103 - 1439 17th Ave SE Calgary AB Canada T2G 1J9 Phone + 1 403 243 8110 orders@pathwayconnect.com www.pathwayconnect.com
© 2017 Acuity Brands Lighting Canada Inc. All Rights Reserved Form #0217-02-1009
1 of 2
06.2017

APPLICATION RISER
eDIN #1009 DMX512/RDM Opto-Splitter
DMX512/RDM
PINOUT :
FOR SHIELDED
TWISTED PAIR
XLR PIN # PURPOSE
1 Shield
2 Data - (complement)
3 Data + (true)
4 Data - (pair 2 complement)
5 Data + (pair 2 true)
DMX512/RDM
PINOUT :
FOR CAT 5/6
XLR PIN # PURPOSE
3 Data 1 + (true)
2 Data 1 - (complement)
5 Data 2 + (true)
4 Data 2 - (complement)
- Not used - do not connect
- Not used - do not connect
1 Shield/COM
1 Shield/Com
Cat5/6 Color and Pin #
1 - White/Orange
2 - Orange
3 - White Green
6 - Green
4 - Blue
5 - White Blue
7 - White/Brown
8 - Brown
ORDERING INFORMATION
PART # DESCRIPTION
1009 eDIN DMX512/RDM Opto-Splitter, 1 in/4 out
ACCESSORIES
1001-30 24VDC - 30W DIN-mountable power supply
1103 Rack-mount panel Kit (2RU) with two 16.5” (420mm) sections of DIN rail
1105 Small eDIN System Enclosure (NEMA1) with 9.5” (240mm) of vertical DIN rail
1106 Large eDIN System Enclosure (NEMA1) with 19.5” (495mm) of vertical DIN rail
1107 Large eDIN System Enclosure (NEMA1) with three horizontal 9.5” (240mm) horizontal DIN rail
1108 Small eDIN System Enclosure (NEMA1) with two horizontal 9.5” (240mm) DIN rail
1109 Expanded eDIN System Enclosure (NEMA1) with three vertical 24”(610mm) DIN rail
#103 - 1439 17th Ave SE Calgary AB Canada T2G 1J9 Phone + 1 403 243 8110 orders@pathwayconnect.com www.pathwayconnect.com
© 2017 Acuity Brands Lighting Canada Inc. All Rights Reserved Form #0217-02-1009