An essential component of any DMX512 distribution system, the use of eDIN Installation Repeaters permits star wiring while isolating and protecting connected equipment from harmful electrical faults. Pathway eDIN Installation Repeaters feature self-resetting protection devices on all ports to prevent internal damage when severe faults of up to 250V are accidentally applied to the connected DMX cabling.
Installation Repeater Installer’s Guide
OPERATIONAL PHILOSOPHY
To ensure trouble-free operation, DMX512 standards re­quire that DMX devices be installed in a daisy chain, with no tees, wyes or stars in the DMX wiring. However, site conditions may make star wiring desirable or even man­datory.
A Pathway eDIN Installation Repeater provides up to 4 eDIN opto-splitter cards, for a total possible 16 output branches. Each branch acts electrically as its own entity, unaffected by faults on other branches of the star.
Opto-isolation circuitry prevents ground loops or damage to control consoles by fault voltages on DMX lines.
MOUNTING
Pathway eDIN Installation Repeaters are designed for indoor use in a dry location. Mount the Installation Re­peater to the wall with appropriate fasteners. Run conduit into the box through the knockouts provided, ensuring that line voltage wiring is kept inside the barriered power supply section.
Model 4808
CONNECTIONS
Pathway eDIN Installation Repeaters are delivered with the power supply pre-wired to the first opto card, and with all required wiring daisy-chained to any additional cards. The following connections must be done on-site.
WARNING
All DMX input/output ports must be connected to low-voltage data lines only. Do not connect high voltage sources to these connectors.
DMX IN is wired to the control console output or DMX
source. DMX OUTs are connected to the remote DMX devices or
the receptacles for the equipment receiving the console signal. These may be dimmers, scrollers, or moving lights, for example.
Power. With the power off, make the appropriate con­nections to Ground, Neutral and Line of the power supply in the barriered section at the top of the cabinet.
ESTA
ENTERTAINMENT SERVICES & T
ECHNOLOGY ASSOCIATION
4807, 4808 4809, 4810
Installation Repeater Installer’s Guide
DMX WIRING
All cabling must be in one continuous run, daisy­chained: no “Tees” allowed
“Stars” are permitted only in conjunction with a re­peater or opto-splitter
Cable shield may be earth-grounded at one end only, preferably at the control console
Maximum length of one cable segment is 1,800 ft (550m)
Receiving devices have male connectors; transmitters have female
The last DMX device on the line must be terminated with a termination switch or resistor with a value of 100 to 120 ohms between pin 2 and 3
5 pin XLR connectors are standard:
Pin 1: Common Pin 2: Data (-) Pin 3: Data (+) Pin 4: Optional Data (-) Pin 5: Optional Data (+)
Cable must be Belden 9842 (120 ) 9829, 9729 (100 ) ISO/IEC 11801 (Cat5) or equivalent
A maximum of 32 DMX receiving devices can be pre­sent on a single DMX line
RECOMMENDED WIRING PRACTICE
Keep all DMX cabling away from high voltage/power ca­bles to maintain data integrity.
Use the appropriate wire for all connections.
DMX Connections: Belden 9829, 9842, Cat5 or equivalent.
Power Connections: Insulated #18-16 AWG, stranded or solid core
EXPANSION INSTRUCTIONS
eDIN Installation Repeaters may hold up to two opto­splitter cards (model 4807 and 4808) or four cards (models 4809 and 4810). If the original enclosure holds less than its limit, it is possible to add cards. It’s also pos­sible to pass through data and low voltage power to a second enclosure.
DMX THRU passes the console signal to the additional eDIN opto-splitter card, where the wires are connected to the DMX IN terminals. While not isolated, DMX THRU can also be used to pass signal to other devices.
Power can also be daisy-chained using the second pair of V+ and V- terminals. Polarity should be followed at the receiving device.
Always disconnect main power before removing the enclosure’s cover. eDIN Installation Repeaters are designed to operate on a mains voltage of 90-
250 volts AC.
DMX TERMINATION
If nothing is connected to the DMX THRU terminal block of the final opto-splitter card, then the termination switch on this card must be set to the ON position. All the other cards are not terminated (switch in the OFF position).
If another card is added, or the signal is passed through to another device, the switch on the final card will need to be moved to the OFF position and the termination applied at the new final device. Always make sure the final re­ceiving device connected to any output or branch line is properly terminated using its internal switch or jumper or if necessary a resistor of 120 between pins 2 and 3.
INDICATORS
The face of each card inside the Installation Repeater has the following LEDs:
The Power LED will illuminate when power is con­nected to the card. There is no on/off switch.
The DMX IN LED will illuminate and flicker rapidly when DMX data is being received.
Each DMX output has a DMX OUT LED that will illu­minate and flicker when DMX is being output by that branch.
DMX 512A COMPLIANCE
This product complies with the DMX512-A standard, un­der the non-compatible connector (NCC) provision. All ports are protected to 250V.
MODEL DESCRIPTIONS
4807 4-way eDIN Installation Repeater 4808 8-way eDIN Installation Repeater 4809 12-way eDIN Installation Repeater 4810 16-way eDIN Installation Repeater
SPECIFICATIONS
POWER SUPPLY: Universal input (90-250V, 50/60 Hz) PSU CONNECTIONS Screw-down terminals; 12 –18 AWG
INPUT & OUTPUT SIGNAL:
ISOLATION: 2500V opto-isolation input to output PROTECTION: Up to 250V AC/DC on all port pins DATA
CONNECTIONS: SIZE: Models 4807/4808 260mm x 509mm x 115mm (10.25” x 13.25” x 4.5”) Models 4809/4810 260mm x 509mm x 115mm (10.25” x 23.25” x 4.5”)
USITT DMX512/1990 and E1.11 (DMX512-A) or any EIA422/485-based protocol
Two piece compression screw terminals, 16 - 24 AWG
rev.1, ver.3
Pathway Connectivity Inc., #103 - 1439 17 Avenue SE Calgary AB Canada T2G 1J9 (403) 243-8110 fax (403) 287-1281