pass & seymour RWU600U Installation Instructions Manual

Installation Instructions
Please read all instructions before installing
Visit our website at: www.passandseymour.com
RWU600U
PIR Occupancy Sensor Switch
with Manual
ON/OFF
SPECIFICATIONS
Load (Single Pole Circuit)
Incandescent or fluorescent light . . . . . . . . . . . 0-600 Watt
Fan motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/6 hp
Operating Temperature . . . . . . . .32° to 131°F (0° to 55°C)
Humidity . . . . . . . . . . . . . . . . . . . .95% RH, non-condensing
Tools Needed:
Insulated Screwdriver
Wire Strippers
Lens
Lighted Switch ON/OFF button
TEST MODE
To test the detection coverage:
During the TEST mode, the controlled load turns ON for 5 seconds each time the sensor detects occupancy.
1. Press and hold the ON/OFF button. After 10 seconds the lighted switch flashes. The load turns ON if it was not already ON. The sensor is now in a TEST mode that lasts 5 minutes. (You can end the TEST mode sooner by pressing the ON/OFF button for another 10 seconds).
2. Move out of the coverage area or stand very still. The controlled load turns OFF after 5 seconds, if no motion is detected.
3. Move into the coverage area. The controlled load turns ON for 5 seconds each time the sensor detects motion. After 5 seconds expire without motion detection, the load turns OFF. The controlled load turns ON automatically with the next motion detection and stays ON for 5 seconds.
4. Repeat as necessary to ensure that the desired coverage areas are within detection range.
TROUBLESHOOTING
Load will not turn ON (lighted switch is visible):
• Move in front of the sensor to automatically turn lights ON. If lights do not turn ON, press the ON/OFF button. The lighted switch should turn OFF and the controlled load should turn ON, if not:
• Check the light bulb.
• Turn OFF power to the circuit then check wire connections.
• Remember that if the load is turned OFF manually, Automatic-ON is reenabled only after no motion is detected for 5 minutes.
Light will not turn ON (lighted switch is NOT visible):
• Check the light bulb.
• Make certain that the circuit breaker is ON and functioning.
• Turn OFF power to the circuit then check wire connections.
P.O. Box4822, Syracuse, NY 13221-4822
Technical Support: 800.223.4185 • www.passandseymour.com
340802 Rev. B 08131
Limited FIVE YEAR Warranty
Pass & Seymour/Legrand will remedy any defect in workmanship or material in Pass & Seymour/Legrand products which may develop under proper and normal use within five years from the date of purchase by a consumer:
(1) by repair or replacement, or, at Pass & Seymour/Legrand’s option, (2) by return of an amount equal to the consumer’s purchase price. Such remedy is IN LIEU OF ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES OF MERCHANT
ABILITY OR FITNESS F
OR A PARTICULAR PURPOSE. Such remedy by Pass & Seymour/Legrand does not include or cover cost of labor for removal or reinstallation of the product. ALL OTHER FURTHER ELEMENTS OF D
AMA
GE (INCIDENTAL OR CONSEQUENTIAL DAMAGES) FOR BREACH OF ANY AND ALL EXPRESSED OR
IMPLIED WARRANTIES INCL
UDING WARRANTIES OF MERCHANT
ABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXCLUDED HEREBY. (Some states do not allow disclaimer or exclusion or limitation of incidental or c
onsequential damages, so the above disclaimers and limitation or exclusion may not apply to you.) ANY
IMPLIED W
ARRANTIES INCLUDING WHERE REQUIRED W
ARRANTIES OF MERCHANTABILITY OR FITNES
S FOR A PARTICULAR PURPOSE SHALL BE LIMITED TO THE FIVE YEAR PERIOD SET FORTH ABOVE. (Some states do not all
ow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.)
T
o ensure saf
ety, all repairs to Pass & Seymour/Legrand products must be made by Pass & Seymour/Legrand or
under its specific dir
ection. Pr
oc
edur
e t
o obt
ain perf
ormance of any warranty obligation is as follows: (1) Contact
Pass & Seymour/Legrand, P.O. Box 4822, Syracuse, NY 13221 for instructions concerning return or repair;
2) return the pr
oduct to Pass & Seymour/Legrand, postage paid, with your name and address and a written
description of the ins
t
allation or use of the P
as
s & Se
ymour/Legr
and pr
oduct, and the observed defects or failure
to operate, or other claimed basis for dissatisfaction.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Load will not turn OFF:
The time delay is 5 minutes (fixed time delay).
• Make sure no motion occurs in the coverage area until the time delay
expires.
• If the load does not turn OFF, call Technical Support at 800.223.4185.
• Hot air currents and heat radiant devices can cause false detection. Make
sure the sensor is at least 6 feet (2 meters) away from devices that are a significant heat source (e.g heater, heater vent, high wattage light bulb).
• Press the ON/OFF button. If the controlled load does not turn OFF, turn OFF
the power to the circuit, then check wire connections.
340802RevB_Eng 4/23/07 3:36 PM Page 2
Visit our website at: www.passandseymour.com
Call 800.223.4185 for Technical Support
DESCRIPTION AND OPERATION
The RWU600U Occupancy Sensor Switch is designed to replace a residential light switch. It is ideal for laundry rooms, utility rooms, storage areas, closets and any other indoor area in a residential building where occupancy sensor­based automatic ON/OFF controls are desirable. The sensor requires no adjustments to operate successfully in those particular applications for which it was designed.
Lighted Switch
To help you locate the RWU600U in a dark room, a green LED illuminates the ON/OFF button while the controlled light (load) is OFF. When the load is ON, the LED is OFF.
Push Button
The push button can be used to manually turn ON and OFF the load. To turn the load OFF, tap firmly on the push button once. The lighted switch will turn ON and the load will turn OFF. If the load is turned OFF manually, Automatic-ON is reenabled when no motion is detected for 5 minutes.
Time Delay
The RWU600U has a fixed time delay of 5 minutes. Lights will remain ON for 5 minutes after the last motion detection.
Coverage Area
The RWU600U has a maximum range of 180 degrees and a coverage area of 600 sq. feet (56 sq, meters). The sensor must have a clear and unobstructed view of the coverage area. Objects blocking the sensor’s lens may prevent detection thereby causing the light to turn OFF even though someone is in the area.
Windows, glass doors, and other transparent
barriers will obstruct the sensor’s view
and prevent detection.
25'
(7.6m)
12'
(3.7m)
Fig 1: Sensor Coverage Area
WARNING
Disconnect power to the wall switch box by turning OFF the circuit
breaker or removing the fuse for the circuit before installing the
RWU600U, replacing lamps, or doing any electrical work.
INSTALLATION & WIRING
1. Prepare the switch box.
After the power is turned OFF at the circuit breaker box, remove the existing wall plate and mounting screws. Pull the old switch out from the wall box.
2. Identify the type of circuit.
In a Single Pole Circuit (see Fig. 2), two single wires connect to two screws on the existing switch. A ground wire may also be present and connected to a ground terminal on the old switch.
CAUTION
For your safety:
Connecting a proper ground to the sensor provides
protection against electrical shock in the event of certain fault conditions.
If a proper ground is not available, consult with a qualified electrician before
continuing installation.
Only connect the RWU600U to a Single Pole Circuit. The RWU600U is not suitable for 3-way switching. If the existing wiring does not match the description for a Single Pole Circuit, you should consult with a qualified electrician. If 3-way switching is required, use P&S 3-way occupancy sensor, RW3U600.
3. Prepare the wires.
Tag the wires connected to the existing switch, so that they can be identified later. Disconnect the wires. Make sure the insulation is stripped off the wires to expose their copper cores to the length indicated by the “Strip Gage” (in Fig. 3) (approx. 1/2 inch). A neutral wire should also be present in the wall box.
Fig 2:
Typical Single Pole Switch Wiring
Fig 3: Wire Stripping
4. Wire the sensor.
Twist the existing wires together with the wire leads on the RWU600U sensor as indicated below. Cap them securely using the wire nuts provided. See Fig 4.
• Connect the green or non-insulated (copper) GROUND wire from the circuit to the ground terminal on the RWU600U.
• Connect the NEUTRAL wire from the circuit and from the lamp or fan (LOAD) to the white wire on the RWU600U.
• Connect the power wire from the circuit (HOT) to the black wire on the RWU600U.
• Connect the wire to the lamp or fan (LOAD) to the red wire on the RWU600U.
5. Put the RWU600U in the wall box.
Position the lens above the ON/OFF button (lens at top, button at bottom) and secure it to the wall box with the screws provided.
6. Attach the new cover plate.
Secure it to the wall box with the screws provided.
7. Restore power to the circuit.
Turn ON the breaker or replace the fuse.
8. Test the sensor’s operation.
See TEST MODE.
Fig 4: Sensor orientation, wire connections
and wall box assembly
Initial Power-up Delay
Ther
e is an initial warm-up
period the fir
st time power is applied to the unit and after a po
wer failur
e las
ting more
than 5 minut
es. It may take up to 1 minute before the lights turn ON. However, the lights can be turned ON/OFF manually by pressing the ON/ OFF button at any time when power is supplied to the unit.
340802RevB_Eng 4/23/07 3:36 PM Page 5
Loading...
+ 1 hidden pages