Paso Sound Products DMS 3040-40, DMS 3080-80, DMS 3120-120, OM163, DMS 3040 Installation Manual And Operating Instructions

...
© copyright Paso Sound Products, Inc.2003 Specifications are subject to change without notice
Innovation through technology since 1931
Installation Manual
7 Channel - 3 Zone - Dual VOX -
Dual Mute - MOH - Vox Relay -
Module Port - Phone Interface
TTOO RREEDDUUCCEE TTHHEE RRIISSKK OOFF FFIIRREE OORR EELLEECCTTRRIICC
SSHHOOCCKK DDOO NNOOTT EEXXPPOOSSEE TTHHIISS AAPPPPLLIIAANNCCEE TTOO
WWAATTEERR,, RRAAIINN OORR MMOOIISSTTUURREE
CAUTION !
REV. 1.5
IMPORTANT NOTE:
THIS OPERATING MANUAL IS PROVIDED AS AN INSTALLATION AND AS AN OPERATING AID. PASO SOUND PRODUCTS, INC. DOES NOT ASSUME ANY RESPONSIBILITY AS TO ITS ACCURACY AND SHALL NOT BE LIABLE IN TORT OR CON­TRACT FOR ANY DIRECT CONSEQUENTIAL OR INCIDENTAL LOSS OR DAMAGE ARISING FROM THE INSTALLATION, USE OR INABILITY TO USE THIS PRODUCT.
DDMMSS 33004400 -- 4400 WWaatttt RRMMSS
DDMMSS 33008800 -- 8800 WWaatttt RRMMSS
DDMMSS 33112200 -- 112200 WWaatttt RRMMSS
PROFESSIONAL AUDIO & SOUND
®
Series DMS
Integrated Amplifiers
Manual
OOMM 116633
DDiiggiittaall MMuussiicc AAmmpplliiffiieerrss
TM
DIGITAL MUSIC SERIES
DIGITAL MUSIC SERIES
TM
LISTED
COMMERCIAL
AUDIO
EQUIPMENT
30TJ
DESCRIPTION AND APPLICATIONS SPECIFICATIONS
PAGE 2
© copyright Paso Sound Products, Inc.2002 Specifications are subject to change without notice
DMS3040/3080/3120
Power Output:
DMS3040 DMS3080
DMS3120 Distortion: Frequency Response: Inputs:
Input 1
Input 2
Input 3
Input 4
Input 5
Input 6
Input 7 Sensitivity & Z:
Input 1
Input 2
Input 3
Input 4
Input 5
Input 6
Input 7
AUX 1 Input Attenuator:
AUX 2 Input Attenuator: Phantom Power: Hum & Noise: Telephone Paging Input: Accessory Port: EQ LINK: Line Outputs: Inputs/Outputs: Subwoofer Outputs: Subwoofer Output Level: Music on Hold Output: Zone 2 Output: Zone 3 Output: Main Output Impedance: Controls:
Front Panel:
Rear Panel:
Bass and Treble Controls: Tone By-Pass: Remote Volume Controls: MOH Source Selection: Zone 2/3 Source Selection: DUAL VO X: VOXBUSS 1: VOXBUSS 2: MUTE BUSS 1: MUTE BUSS 2: MUTE 2 DELAY: Unmuting: Power Supply Output: Auto VO X Relay:
Rack Mounting: Internal Cooling Fan: Power Requirement: Power Consumption:
AC Accessory Outlet: Terminations: Housing Finish: Output Power Indicator: Dimensions: Net Weight:
DMS3040 DMS3080 DMS3120
UNPACKING
Immediately upon receipt of the amplifier, inspect the unit and shipping container for indications of improper handling or in transit damage.The equipment was carefully inspect­ed and tested before leaving the factory. Notify the Transportation Company immediately if any damage is found. ONLY THE CONSIGNEE CAN FILE A CLAIM WITH THE CARRIER FOR DAMAGE DURING SHIPMENT. Be sure to save the carton and packing material as evidence of damage for the shipper inspection. DO NOT SHIP the unit back to the factory unless authorized by the factory.
IN TRANSIT DAMAGES ARE NOT COVERED BY THE PASO WARRANTY.
40 Watt RMS 80 Watt RMS 120 Watt RMS Less than 0.5% THD 20 - 20,000 Hz ± 1 db
Microphone 1 Balanced Microphone 2 Balanced Microphone 3 Balanced Microphone 4 Balanced - AUX 1
(Stereo Summing)
Microphone 5 Balanced - AUX 2
(Stereo Summing)
Telephone Interface - Transformer Balanced Module Port
Mic 1
= 1.5 Mv - 250 ohm
Mic
2 = 1.5 Mv - 250 ohm
Mic 3
= 1.5 Mv - 250 ohm
Mic 4
= 1.5 Mv - 250 ohm - AUX 1 = 100 Mv - 47K
ohm
Mic 5
= 1.5 Mv - 250 ohm - AUX 2 = 100 Mv - 47K
ohm
Tel
=100 Mv - 600 ohm - Transformer Balanced
Module
= 1 V - 47K ohm Variable (rear panel control) Variable (rear panel control) All Microphone Inputs by internal jumper (18 V)
Mic
-70 db,
Aux
-75 db 600 ohm Transformer balanced Accepts Standard Module Preamp out, Power Amp in with EQ Link Switch Line Out 600 ohm - 1.5 V loaded MIX BUSS Pre-EQ and Post-EQ Outputs 1 Volt 600 ohm-1 Volt Transformer Balanced 1 Watt-8 ohm with Control 1 Watt-8 ohm with Control 8 ohm, 25 Volt and 70 Volt line
Input 1 Level, Input 2 Level, Input 3 Level, Input 4 Level, Input 5 Level, Module Level, Bass and Treble PHONE Level - AUX 1 Attenuator - AUX 2 Attenuator
- MOH/ZONE 1 Level Control - ZONE 2 Level Control
- VOX 1/VOX 2 Sensitivity - MUTE 2 Delay ± 10 dB at 100 Hz and 10 KHz On - Off Switch
(rear panel)
AUX 1 Input Level and Master Volume (10 K) AUX 1 - AUX 2 - MODULE by internal jumper AUX 1 - AUX 2 - MODULE by internal jumper Voice Activated Muting Available on all 7 Inputs by internal jumpers Available on all 7 Inputs by internal jumpers Available on all 7 Inputs by internal jumpers Available on all 7 Inputs by internal jumpers Adjustable from 3 Sec to 30 Sec (rear panel control) MUTES/UNMUTES MIC 1 only 24 V DC - 250 mA Regulated NO/NC Contacts - VOX activated - Contacts Rating = 30 VDC - 7 A Optional Model 27/3501 - 19” Rack Kit 3” Thermally Controlled -
Model DMS3120 only
117 Volt, 50-60 Hz
DMS3040 = AC = 630 VA - DMS3080 = 750 VA - DMS3120 = 850VA Max.
500 W Max. Unswitched Screw Ter minals, RCA Jacks Black Multi-color LED
(front panel)
19” W., 12”D., 4” H. with feet
(482X305X102 mm)
3.5”
H
(89 mm)
. less feet
16 Lbs
(8 Kg)
19 Lbs
(8.5 Kg)
22 Lbs
(11 Kg)
High Performance - High Reliability Design
Wide Frequency Response - Very Low Distortion
7 Channel Inputs - 3 Zone Outputs
5 Balanced Microphone Inputs
Phantom Power on all MIC Inputs
MIC 4/AUX 1 and MIC 5/AUX 2 Inputs
With Stereo Summing
AUX1 and AUX2 Inputs Attenuator
600 ohm Transformer Balanced
Telephone Paging Input
MIX Buss and 600 ohm Line Output
Independent Input Controls
Rear Panel Port: Accepts Standard Module
Independent Module Level Control
AUX1 and Master Remote Volume Controls
External EQ Link
Tone by-pass and EQ Link switches
Pre-EQ Subwoofer Output
Post-EQ Subwoofer Output
Addressable Dual VOX Buss
Voice Activated Muting
VOX Variable Time Delay Function
Addressable Dual MUTE Buss
Direct Muting and Unmuting
600 ohm and 8 ohm 1 Watt
Music on Hold Amplifier
MOH Amplifier Source Selector
Zone 2 and 3, 1 Watt - 8 ohm Output
with Separate Control
NO/NC VOX Operated Relay
24 V DC 250 mA Regulated Power Supply Output
8 ohm, 25 Volt & 70 Volt Output
Optional 19” Rack Mounting with Kit
Low profile - 2-Unit of Vertical Rack space
UL 6500 Listed (US - CANADA)
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
PAGE 3
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
RACK MOUNTING
A) Procure the optional accessory Rack Mount Kit Model 27/3501. B) Turn amplifier up side down and remove the four rubber feet by unscrewing the four holding screws. C) Remove two screws on each side of the amplifier holding the amplifier cover. D) Install the rack kit brackets by using the self-tapping screws provided.
DMS
Fig. 3 - Rack Kit Mounting
READ BEFORE OPERATING READ BEFORE OPERATING
BEFORE OPERATING THE AMPLIFIER, BE SURE YOU FULLY UNDERSTAND ALL INSTRUCTIONS AND FEA­TURES OF THE UNIT.
1)
Read these instructions carefully.
2)
Keep these instructions.
3)
Heed all Warnings.
4)
Follow all instructions.
5) DO NOT use this apparatus near water.
6) Clean ONLY with a damp cloth.
7) DO NOT block any of the ventilation openings.
Install in accordance with the instructions provided.
8) DO NOT install near any heat sources such as radiators, stoves, or other apparatus (including ampli­fiers) that produce heat.
9) DO NOT mount amplifier into a container or a closed unventilated closet while operating.
10) DO NOT place any object or accessory equipment such as Tuners, Mixers, Cassette Decks, etc.on top of the amplifier. Obstructing or closing the cabinet venti­lation openings may cause overheating.
11) DO NOT defeat the safety purpose of the polar­ized or grounding type plug. A polarized plug has two blades with one wider than the other .A grounding type plug has two blades and a third grounding prong.The wide blade and or the third prong is provided for your safety. When the provided plug does not fit into your
outlet, consult an electrician for replacement of the obsolete outlet.
12) Use only the attachments and accessories speci­fied in this manual.
13) If a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip­over.
14) Unplug this apparatus during lighting storms or when unused for long periods of time.
15) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have f allen into the appar atus, the appar atus has been exposed to rain or moisture, does not operate normal­ly, or has been dropped.
16) DO NOT replace fuses unless power cord is removed from the AC wall outlet.
17) DO NOT install accessories unless the power cord is removed from the AC wall outlet.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO WATER, RAIN OR MOISTURE
IMPORTANT SAFETY INSTRUCTIONS
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
DMS
DIGITAL MUSIC SERIES
100 100 100 100 100 100 +10-10 +10-10
INPUT 1 INPUT 2 INPUT 3 INPUT 4/AUX 1 INPUT 5/AUX 2 BASS TREBLEMODULE
TM
DIGITAL MUSIC AMPLIFIER
PROFESSIONAL AUDIO & SOUND
OUTPUT LEVEL
POWER
PEAK
O
PAGE 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
DMS
1) INPUT 1 Volume Control
2) INPUT 2 Volume Control
3) INPUT 3 Volume Control
4) INPUT 4/AUX 1 Volume Control
5) INPUT 5/AUX 2 Volume Control
6) Input Module Level Control
7) BASS Control
8) TREBLE Control
9) On-Off Power Switch
10) Output Level Meter
Fig. 4 - FRONT PANEL CONTROLS
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
PEAK
TM
DIGITAL MUSIC SERIES
10
OUTPUT LEVEL
PROFESSIONAL AUDIO & SOUND
POWER
O
DIGITAL MUSIC AMPLIFIER
TM
DIGITAL MUSIC SERIES
DMS
5 6 7 8 9
2 3 4
100 100 100 100 100 100 +10-10 +10-10
1
INPUT 1 INPUT 2 INPUT 3 INPUT 4/AUX 1 INPUT 5/AUX 2 BASS TREBLEMODULE
PAGE 5
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
Fig. 5- REAR PANEL INPUTS - OUTPUTS - CONTROLS
1) Unswitched AC Auxiliary Socket
2) ZONE 1 - Output Level Control
3) Zone 1 MOH - 600 ohm, 1 Volt Output
4) Zone 1 - 8 ohm, 1 Watt Output
5) Zone 2 - 8 ohm, 1 Watt Output
6) ZONE 2 - Output Level Control
7) VOX Relay NO/NC Contact Terminals
8) 24 Volt DC Regulated Power Supply Output
9) MIC 1 UNMUTE
10) MUTE 1 - MUTE 2 Terminals
11) Master Remote Volume Control Terminals
12) EQ LINK - IN - OUT Switch
13) EQ LINK - PREAMP. OUT/POWER AMP IN
14) SUB OUT - PRE EQ and POST EQ
15) MIX BUSS
16) LINE OUT 600 Ohm
17) TONE BYPASS - ON/OFF SWITCH
18) AUX 1 Input Attenuator
19) INPUT 4/AUX 1 - Stereo Summing Jacks
20) INPUT 5/AUX 2 - Stereo Summing Jacks
21) AUX 2 Input Attenuator
22) Standard Module Port
23) TELEPHONE Paging Output Level Control
24) TELEPHONE Paging Balanced Input 600 Ohm
25) INPUT 5/AUX 2 - Balanced Input
26) INPUT 4/AUX 1 - Remote Volume Control Ter minals
27) INPUT 4 - Balanced MIC Input
28) INPUT 3 - Balanced MIC Input
29) INPUT 2 - Balanced MIC Input
30) INPUT 1 - Balanced MIC Input
31) MUTE 2 Time Delay Control
32) VOX 2 Sensitivity Control
33) VOX 1 Sensitivity Control
34) Speaker Output Terminals
35) Chassis Ground
36) AC LIne Fuse
37) AC Power Cord
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
22
MODULE
STANDARD
PORT ACCEPTS
20
21
L
47kohm 100mV
INPUT-5(AUX2)
(AUX2)
ATTENUATOR
R
INPUT 5
19
INPUT-4(AUX1)
17
47kohm 100mV
MIX
BUSS
PRE EQ
SUB OUT
PRE
OUT
30TJ
AUDIO
LISTED
EQUIPMENT
COMMERCIAL
CUS
RVC
MASTER
REMOTE
VOLUME MUTE 1
M1 RVC
MUTE 2
GROUND
UNMUTE
MIC1 G M2
24V DC
250 mA
+-
VOX RELAY
NC C NO
ZONE 2
(AUX1)
ATTENUATOR
EQ LINK
LEVEL
OFF
TONE
ON
LINE OUT
SUB OUT
POWER
EQ LINK
IN OUT
CAUTION
RISK OF ELECTRIC SHOCK
DMS3120
PROFESSIONAL AUDIO & SOUND
18
16
15
14
13
12
11
10
9
8
7
6
CAUTION: REMOVE
SWITCH
MIC-AUX2
BY INTERNAL
TEL OUTPUT
TEL
BYPASS
AUX2
47Kohm 100 mV
INPUT5 (MIC-AUX2)
600
INPUT 4
VOLUME
REMOTE
POST EQ
INPUT 4 (MIC) INPUT 3 (MIC)
IN
INPUT 2 (MIC)
DO NOT OPEN
MUST BE EARTHED
INPUT 1 (MIC)
WARNING: THIS APPLIANCE
850 VA
120 W RMS
117V 60 HZ
VOX-2 MUTE-2
DIGITAL MUSIC AMPLIFIER
POWER RATING
SUPPLY VOL TAGE
POWER CONSUMPTION
INSTALLING MODULE
POWER CORD FROM
AC OUTLET PRIOR TO
LEVEL
G COM HOT
G COM HOT RVC RVC G COM HOT G COM HOT G COM HOT G COM HOT
DELAY
SENS
SENS
VOX-1
600 ohm 100mV
BALANCED
250ohm 1.5mV
SER. NO.
23
2425262728293031323334
5
4
3
2
0 8
ZONE 2
0 8
ZONE 1
0 600
AFIN DE REDUIRE LE RISQUE
LEVEL
ZONE 1
ATTENTION:
D'INCENDIE REMPLACER SEUL PAR UN
FUSIBLE DE MEME TYPE.
1
CAUTION: TO REDUCE THE
RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE
FUSE.
1 WA TT
1 WA TT
ATTENTION: POUR REDUIRLES RISQUES D' INCENDIE
OU DE CHOC ELECTRIQUE, NE PAS EXPOSER A LA PLUIE
OU L' HUMIDITE, NE PAS ENLEVER LE COUVERCLE. AUCUN
REGLAGE A L' INTERIEUR. POUR REPARATION CONSULTER
UNE PERSONNE QUALIFIEE
COM 8 25V 70V
BALANCED
MOH OUT
GROUND
CAUTION: TO REDUCE THE RISK OF FIRE OR
SHOCK DO NOT EXPOSE THIS APPLIANCE TO
RAIN OR MOISTURE. DO NOT REMOVE COVER.
THERE ARE NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
UNSWITCHED
117V 500W MAX
SPEAKER OUTPUT
CLASS 2 WIRING ACCEPTABLE
DMS3120 Rear Panel
Manual
35
5A 250V
LINE FUSE
117V 60HZ
36
37
PAGE 6
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
Fig. 6 - MAIN PCB AND MOH BOARD TOP VIEW
FUNCTION SWITCHES AND JUMPERS LOCATION
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
SOCKET
OPTIONAL
CHIME CARD
CN 213
DIGITAL MUSIC SERIES
REV - 0
DMS3120 - 7
M. O. H. BOARD
DMS3120 - 7
M.O.H. BOARD
TM
SW206
VOX RELAY
MIC 1
SW201
POWER
ON OFF
PHANTOM
MIC 2
SW202
POWER
ON OFF
PHANTOM
MIC 3
SW203
POWER
ON OFF
PHANTOM
AMPLIFIER REAR PANEL
MIC 4
SW204
POWER
ON OFF
PHANTOM
SW228
INPUT 4
SWITCH
AUX1 MIC4
AUX1 MIC4
POWER
PHANTOM
INPUT5
AUX2 MIC5
INPUT5
MIC 5
SW207
SWITCH
SWITCH
AUX2 MIC5
ON OFF
SW229
AUX2 MIC5
SW208
AUX2 MIC5
MODULE
SW205
ON OFF
MIC1 UNMUTE
M2 M1
INPUT 1
INPUT 2
INPUT 3
INPUT 4
INPUT 4
REMOTE
AUX 2
TEL
INPUT
SW209
AUX1 AUX2
SOURCE SWITCH
SW227
M2 M1
CHIME TRIGGER
(MIC)
(MIC)
(MIC)
(MIC)
VOLUME
INPUT 5
SW227
M2 M1
(CHIME TRIGER)
ON OFF
SW205
(UNMUTE)
M2 M1
SW206
(VOX RELAY)
ON OFF
SW201 (MIC1)
SW215
INPUT1
V2 V1 OFF
SW220
INPUT1
SW219
INPUT2
SW218
(INPUT4/AUX1)
SW223
INPUT5/AUX2
(TEL)
SW216
V2 V1 OFF
M2 M1 OFF
V2 V1 OFF
V2 V1 OFF
INPUT3
SW217
V2 V1 OFF
M2 M1 OFF
M2 M1 OFF
SW221
SW222
M2 M1 OFF
SW210
M2 M1 OFF
SW211
M2 M1 OFF
SW212
V2 V1 OFF
M2 M1 OFF
SW213
V2 V1 OFF
(MODULE)
(MODULE)
INPUT2
T204
INPUT3
(INPUT4/AUX1)
(TEL)
SW214
HOT COM GND HOT COM GND
ON OFF
SW202 (MIC2)
ON OFF
SW203 (MIC3)
HOTRVC RVC COM GNDHOT COM GNDHOT COM GND HOT COM GND
ON OFF
SW204 (MIC4)
SW207
SW208
(INPUT5)
(MIC5)
ON OFF
AUX2 MIC
SW209
(MODULE IN)
AUX2 AUX1
SW228
(INPUT4)
AUX1 MIC4
SW229
(INPUT5)
AUX2 MIC5
REAR PANEL
IT - 5000
(INPUT5/AUX2)
ZONE 1
SW702
AUX2 AUX1 MOD
AUX2 AUX1 MOD
ZONE 1
SW701
SW701
AUX2 AUX1 MOD
SW220
M1 M2 OFF
SW219
M1 M2 OFF
SW218
M1 M2 OFF
SW217
M1 M2 OFF
SW223
M1 M2 OFF
SW216
M1 M2 OFF
SW222
M1 M2 OFF
SW702
ZONE 2
JUMPER
AUX2 AUX1 MODULE
INPUT1
JUMPER
MUTE1 MUTE2
INPUT2
JUMPER
MUTE1 MUTE2
INPUT3
JUMPER
MUTE1 MUTE2
JUMPER
INPUT4 AUX1
MUTE1 MUTE2
JUMPER
INPUT5 AUX2
MUTE1 MUTE2
JUMPER
TEL PAGING
MUTE1 MUTE2
JUMPER
MODULE
MUTE1 MUTE2
ZONE 1
AUX2 AUX1 MOD
SW215
V1 V2 OFF
SW210
V1 V2 OFF
SW211
V1 V2 OFF
SW212
V1 V2 OFF
SW213
V1 V2 OFF
SW214
V1 V2 OFF
SW221
V1 V2 OFF
JUMPER
AUX2 AUX1 MODULE
INPUT1
JUMPER
VOX1 VOX2
INPUT2
JUMPER
VOX1 VOX2
INPUT3
JUMPER
VOX1 VOX2
JUMPER
VOX1 VOX2
INPUT4 AUX1
JUMPER
VOX1 VOX2
INPUT5 AUX2
JUMPER
TEL PAGING
VOX1 VOX2
JUMPER
MODULE
VOX1 VOX2
DMS3120 - 1
MAIN BOARD
PAGE 7
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
DMS3040/3080/3120
FUNCTION SWITCHES AND JUMPERS DEFAULT SETTING TABLE
SW201 INPUT 1 - PHANTOM POWER ON - OFF OFF SW202 INPUT 2 - PHANTOM POWER ON - OFF OFF SW203 INPUT 3 - PHANTOM POWER ON - OFF OFF SW204 INPUT 4 - PHANTOM POWER ON - OFF OFF SW205 INPUT 1 (MIC 1) - UNMUTE ON - OFF OFF SW206 VOX RELAY - MUTE 1 - MUTE 2 M1 SW207 INPUT 5 - PHANTOM POWER ON - OFF OFF SW210 INPUT 2 - VOX 1 - VOX 2 - OFF OFF SW211 INPUT 3 - VOX 1 - VOX 2 - OFF OFF SW212 INPUT 4 - VOX 1 - VOX 2 - OFF OFF SW213 INPUT 5 - VOX 1 - VOX 2 - OFF OFF SW214 TEL IN - VOX 1 - VOX 2 - OFF V1 SW215 INPUT 1 - VOX 1 - VOX 2 - OFF V1 SW216 TEL IN - MUTE 1 - MUTE 2 - OFF OFF SW217 INPUT 4/AUX 1 - MUTE 1 - MUTE 2 - OFF M1 SW218 INPUT 3 - MUTE 1 - MUTE 2 - OFF OFF SW219 INPUT 2 - MUTE 1 - MUTE 2 - OFF OFF SW220 INPUT 1 - MUTE 1 - MUTE 2 - OFF OFF SW221 MODULE - VOX 1 - VOX 2 - OFF OFF SW222 MODULE - MUTE 1 - MUTE 2 - OFF OFF SW223 INPUT 5/AUX 2 - MUTE 1 - MUTE 2 - OFF M1 SW227 CHIME TRIGGER - MUTE 1 - MUTE 2 M1
JUMPER AND JUMPER FUNCTION FACTORY FACTORY
SWITCH ID NO. REFERENCE DESCRIPTION SETTING SETTING
MAIN PCB JUMPERS
SW208 INPUT 5 - MIC 5 OR AUX 2 SWITCH AUX 2 SW209 MODULE IN SOURCE - AUX 1 OR AUX 2 SWITCH AUX 1 SW228 INPUT 4 - MIC 4 OR AUX 1 SWITCH AUX 1 SW229 INPUT 5 - MIC 5 OR AUX 2 SWITCH AUX 2
SWITCHES
SW701 ZONE 2 INPUT SOURCE - AUX 1 - AUX 2 - MODULE AUX 1 SW702 ZONE 1 INPUT SOURCE - AUX 1 - AUX 2 - MODULE AUX 1
MOH BOARD JUMPERS
SW301 TONE BYPASS Defeats Front Panel Bass & Treble SWITCH OFF SW302 EQ LINK Inser ts Exter nal EQ between SWITCH OUT
Preamp out and Power Amp Input
REAR PANEL SWITCHES
THE FOLLOWING INSTRUCTIONS REQUIRE THE REMOVAL OF THE AMPLIFIER PROTECTIVE COVER AND ARE PROVIDED FOR USE BY QUALIFIED PERSONNEL ONLY.
TO AVOID THE RISK OF ELECTRICAL SHOCK DO NO T PERFORM ANY INSTALLA TION OR SERVICING UNLESS YOU ARE QUALIFIED TO DO SO. REFER INSTALLATION OR SERVICING TO QUALIFIED PERSONNEL.
CAUTION !
REMOVAL OF THE AMPLIFIER COVER PRESENTS AN ELECTRICAL SHOCK HAZARD
ALWAYS REMOVE THE POWER CORD FROM THE AC WALL OUTLET
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
PAGE 8
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
FUNCTION SWITCHES AND JUMPERS
UNDERSTANDING THE INPUT FUNCTIONS
DUAL VOX AND DUAL MUTE - The Amplifier provides two inde-
pendent VOX (V1 & V2) and two MUTE (M1 & M2) SYSTEMS FUNCTION SOCKETS - EACH INPUT IS PROVIDED WITH A
VOX (V1 & V2) AND A MUTE (M1 & M2) SOCKET. INPUTS VOX AND MUTE FUNCTION - All Inputs including the
Module provide 2 - VOX SEND and 2 MUTE RECEIVE functions. The V OX and MUTE functions are SWITCHED-ON, on each Input, by Internal Jumpers provided for each Input. Two VOX BUSS SEND (V1 & V2) and two MUTE BUSS RECEIVE (M1 & M2) can be independently or simultaneously SWITCHED-ON to suit the application requirement.
Fig. 8 - Any Input VOX and MUTE Functions
JUMPER SETTINGS - The VOX and MUTE Functions are
SWITCHED-ON or OFF by setting the JUMPERS on the VOX (A) and MUTE (B) SOCKET. See Fig. 8A.
The SOCKETS are located on the Main PCB inside the Amplifier as shown on the SWITCHES and JUMPERS LOCATION DIA­GRAM in this Manual.Each Socket is identified by an ID NUMBER and the FUNCTION and DEFAULT settings are listed on the FUNCTION SWITCHES and JUMPERS DEFAULT SETTING TABLE in this Manual.
TO SET: Lift the Jumper and reset as required. making sure that the JUMPER is properly positioned over the two shorting pins.
The VOX JUMPER has three positions: OFF,V1 and V2 The MUTE JUMPER has three positions: OFF, M1 and M2
Fig. 8B - Any Input VOX 1 and MUTE 2 Activated
The figure below shows how the VOX 1 Logic Switch and the MUTE 2 Logic Switch are SWITCHED-ON by moving the Jumpers from the OFF position to the V 1 and M 2 position.When the Input is activated by a Source signal the corresponding VOX Signal is sent to the V1 BUSS .When the VOX 2 is activated by another Input the MUTE Signal is present on the MUTE 2 BUSS and it will MUTE this Input
SETTING THE VOX AND MUTE JUMPERS
Fig. 8A - VOX and MUTE Sockets
More than one JUMPER may be used on a VOX SOCKET as shown below. In this example both the VOX 1 and VOX 2 functions are SWITCHED -ON when the Input is activated.For this purpose additional JUMPERS are packed with each Amplifier.
SETTING MORE THAN ONE FUNCTION
More than one JUMPER may be used on a MUTE SOCKET as shown below. In this example both the MUTE 1 and MUTE 2 func­tions will MUTE this INPUT when either VOX 1 or VOX 2 are acti­vated by other INPUTS.
NOTE: BE SURE NOT TO SET BOTH THE VOX AND CORRE­SPONDING MUTE ON THE SAME INPUT OR THE INPUT WILL MUTE ITSELF WHEN ACTIVATED.
EXAMPLE: INPUT 1 - V 1 and M 1 BOTH ON.
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
VOX SEND
SOURCE IN
ANY
V1
V2
AUDIO OUT
TO V OX BUSS 1 TO V OX BUSS 2
INPUT
MUTE RECEIVE
DMS Anyinput
M1
M2
FROM MUTE BUSS 1 FROM MUTE BUSS 2
OFF
VOX SEND
SOURCE IN
ANY
V1
V2
AUDIO OUT
JUMPER
SW215
VOX 2 BUSS ON
X
VOX 2 BUSS OFF
JUMPER
INPUT
SW220
MUTE RECEIVE
DMS Anyinput 02
M1
M2
OFF
X
MUTE 1 BUSS OFF
JUMPER
MUTE 2 BUSS ON
SOCKET
ID NO.
OFF
V 1
Vox Mute Socket
VOX JUMPERS
SOCKET
SW215
JUMPER JUMPER
V 2
AB
MUTE JUMPERS
SOCKET
SW220
OFF
M 1
M 2
JUMPER
OFF
JUMPER
Vox Socket 01
V 1
V 2
JUMPER
VOX SOCKET
OFF
JUMPER
MUTE SOCKET
M 1
M 2
Mute Socket 01
JUMPER
A
B
VOX 1 BUSS ON
VOX 2 BUSS ON
MUTE 1 BUSS ON
MUTE 2 BUSS ON
PAGE 9
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
FUNCTION SETTINGS EXAMPLES
EXAMPLE 9
EXAMPLE 9B
EXAMPLE 9A
EXAMPLES
EXAMPLE 9 - INPUT 1 (MIC 1) mutes INPUT 4/AUX 1. When the Microphone is activated the Music on AUX 1 is muted.
EXAMPLE 9A - INPUT 1 (MIC 1) and TEL IN (Phone Paging) both mute INPUT 4/AUX 1. When the Microphone or the Phone Paging are activated the Music on AUX 1 is muted.The Microphone has pri­ority over the Phone Paging.When MIC 1 is activated both the Phone Paging and the Music on AUX 1 are muted.
EXAMPLE 9B - INPUT 1 (MIC 1) mutes INPUT 4/AUX 1 and INPUT 5/AUX 2. INPUT 4 (Jukebox) mutes INPUT 5 (Sat. Rcvr). When the Jukebox is turned-On the Background Music on AUX 2 is muted. MUTE 2 DELAY (Reference 31) Control is provided.The Microphone Paging has priority over the Background Music and the Jukebox.
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
VOX SEND
MIC IN
WHEN MIC 1 IS ACTIVATED THE VOX 1 BUSS IS SWITCHED-ON AND THE SIGNAL PRESENT ON THE MUTE 1 BUSS WILL MUTE INPUT 4/AUX 1
VOX SEND
MUSIC
IN
WHEN MIC 1 IS ACTIVATED THE VOX 1 BUSS IS SWITCHED-ON AND THE SIGNAL PRESENT ON THE MUTE 1 BUSS WILL MUTE THE MUSIC FROM INPUT 4/AUX 1
MUTE RECEIVE
VOX - MUTE JUMPERS SETTING
V1
V2
INPUT 4
AUX 1
Input 1-4 - V1 - 01
MIC OUT
M1
M2
V1
V2
MUSIC OUT
M1
M2
INPUT 1
MUTE RECEIVE
OFF
OFF
OFF
OFF
X X
X
JUMPER
SW215
SW220
JUMPER
JUMPER
SW212
SW217
JUMPER
VOX 1 BUSS ON
X
VOX 2 BUSS OFF
JUMPER
MUTE 1 BUSS OFF
MUTE 2 BUSS OFF
VOX 1 BUSS OFF
X X
VOX 2 BUSS OFF
MUTE 1 BUSS ON
MUTE 2 BUSS OFF
VOX - MUTE JUMPERS SETTING
V1
V2
MIC IN
WHEN MIC 1 IS ACTIVATED THE VOX 1 BUSS AND THE VOX 2 BUSS ARE SWITCHED­ON AND THE SIGNALS PRESENT ON THE MUTE 1 & 2 BUSS WILL MUTE THE INPUT 4/AUX 1 AND
INPUT 5/AUX 2
JUKEBOX
IN
WHEN INPUT 4AUX 1 IS ACTIVATED THE VOX 2 BUSS IS SWITCHED-ON AND THE SIGNAL PRESENT ON THE MUTE 2 BUSS WILL MUTE THE MUSIC FROM
INPUT 5/AUX 2
MUTE-2 DELAY
3 to 30 Sec
31
MUSIC
IN
INPUT 5/AUX 2 IS MUTED BY BOTH INPUT
4/AUX 1 AND INPUT 1
WHEN ACTIVATED.
INPUT 1
INPUT 4
AUX 1
INPUT 5
AUX 2
Input 1-4 -5 - 03
MIC OUT
M1
M2
V1
V2
JUKEBOX OUT
M1
M2
V1
V2
MUSIC OUT
M1
M2
OFF
OFF
OFF
OFF
OFF
OFF
X X
X
JUMPER
SW215
SW220
JUMPER
MUTE 1 BUSS OFF
MUTE 2 BUSS OFF
JUMPER
SW212
SW217
MUTE 1 BUSS ON
JUMPER
X
JUMPER
SW213
SW223
MUTE 1 BUSS ON
JUMPER JUMPER
MUTE 2 BUSS ON
VOX 1 BUSS ON
X
VOX 2 BUSS OFF
JUMPER
VOX 1 BUSS OFF
X
VOX 2 BUSS ON
VOX 1 BUSS OFF
X X
VOX 2 BUSS OFF
MUTE 2 BUSS OFF
VOX 1 BUSS
MUTE 1 BUSS
VOX 1 BUSS
MUTE 1 BUSS
VOX 2 BUSS
MUTE 2 BUSS
VOX 2 BUSS
MUTE 2 BUSS
VOX - MUTE JUMPERS SETTING
SW215
SW220
JUMPER
X X
SW214
SW216
X
JUMPER
SW212
SW217
JUMPER
X
JUMPER
JUMPER
JUMPER
JUMPER
VOX 1 BUSS ON
VOX 2 BUSS ON
JUMPER
MUTE 1 BUSS OFF
MUTE 2 BUSS OFF
VOX 1 BUSS ON
X
VOX 2 BUSS OFF
MUTE 1 BUSS OFF
MUTE 2 BUSS ON
VOX 1 BUSS OFF
X X
VOX 2 BUSS OFF
MUTE 1 BUSS ON
MUTE 2 BUSS OFF
VOX 1 BUSS
VOX 2 BUSS
MUTE 1 BUSS
MUTE 2 BUSS
VOX SEND
MIC IN
WHEN MIC1 IS ACTIVATED THE VOX 1 BUSS AND THE VOX 2 BUSS ARE SWITCHED­ON AND THE SIGNALS PRESENT ON THE MUTE 1 & 2 BUSS WILL MUTE THE TEL INPUT AND INPUT 4/AUX 1
VOX SEND
TEL IN
WHEN THE TEL INPUT IS ACTIVATED THE VOX 1 BUSS IS SWITCHED-ON AND THE SIGNAL PRESENT ON THE MUTE 1 BUSS WILL MUTE INPUT 4/AUX 1
MUTE RECEIVE
VOX SEND
MUSIC
IN
WHEN MIC1 OR TEL ARE ACTIVATED THE VOX 1 BUSS IS SWITCHED-ON AND THE SIGNAL PRESENT ON THE MUTE 1 BUSS WILL MUTE THE MUSIC FROM
INPUT 4/AUX 1
MUTE RECEIVE
INPUT 1
MUTE RECEIVE
TEL INPUT
INPUT 4
AUX 1
Input 1-4 -Tel - 01
V1
V2
MIC OUT
M1
M2
V1
V2
PHONE OUT
M1
M2
V1
V2
MUSIC OUT
M1
M2
OFF
OFF
OFF
OFF
OFF
OFF
PAGE 10
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
INPUT 1 SETTING AS A MICROPHONE INPUT
MICROPHONE TYPE
The Microphone Input accepts Low Impedance (250-600 ohm) Dynamic Microphones.The Microphone may be a balanced output type (three wire) or an unbalanced output type (two wire).
PASO MICROPHONES
All PASO low impedance Microphones have a balanced output for best performance. Connect the RED lead to terminal HOT, the WHITE lead to terminal COM and the SHIELD to terminal G.
WIRING
CABLE
MICROPHONE INPUT
Attach the microphone leads to the ter­minal strip as per diagrams at left.
DO NOT GROUND THE MICROPHONE CABLE SHIELD TO THE CHASSIS OF THE AMPLIFIER
BALANCED MICROPHONE
IMPORTANT NOTE: The use of an unbalanced Microphone (two leads) is not recommended. For best results in a PA Application always use a Unidirectional Dynamic, Low Impedance, Balanced Microphone (three leads).
UNBALANCED MICROPHONE
Attach the Microphone leads to the ter­minal strip as per diagram in Fig 8A.The cable length should not exceed: 15 Ft. (4.5 m).
Fig. 10 - Balanced Microphone Input 1 Wiring
CAUTION:
TO PREVENT POSSIBLE DAMAGE TO SPEAKERS OR THE AMPLIFIER
ALL INPUT CONNECTIONS MUST BE MADE WITH THE AMPLIFIER POWER OFF.
CABLE LENGTH - If the distance between the Microphone and the Amplifier Input is greater than 15 ft (4.5 m) a Balanced Microphone must be used. Use a two conductor shielded wire and connect Microphone to Amplifier as per Diagram in Fig. 10.
MICROPHONE CABLE ROUTING - The Microphone Cable should be carefully routed. Improper Cable routing will cause spurious oscillations, regenerative noises, hum, etc. that may permanently damage the Amplifier.
z Do not route cable next to power
lines.
z
Do not route cable near or over Fluorescent Fixtures.
z
Do not route cable next to Speaker Wires.
z
Do not install cable inside Power Line Conduits.
z
Avoid the use of staples that may penetrate the cable.
Fig. 10A - Unbalanced Microphone Input 1 Wiring
INSTALLATION AND WIRING
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
THREE LEADS BALANCED MICROPHONE WIRING
VOX - MUTE JUMPERS SETTING
V1
VOX SEND
MIC IN
Input 1 - V1 - 01
MUTE RECEIVE
The microphone leads color refers to Paso Microphones only. When using other brand refer to instructions packed with that unit.
V2
INPUT 1
OFF
AUDIO OUT
OFF
M1
X X
M2
SHIELD
SW215
VOX 1 BUSS ACTIVATED
JUMPER
X
VOX 2 BUSS OFF
JUMPER
=
JUMPER
SW220
JUMPER
MUTE 1 BUSS OFF
MUTE 2 BUSS OFF
MIC
Lo Z
INPUT 1 - Default Jumper Settings
The Diagram at Left shows the Default Settings for INPUT 1.
VOX 1 is SWITCHED ON VOX 2 is SWITCHED OFF MUTE 1 is SWITCHED OFF MUTE 2 is SWITCHED OFF
When the INPUT 1 (MIC 1) is activated the VOX 1 BUSS is ON and it will MUTE any Input with the MUTE 1 Setting SWITCHED ON.
INPUT 1 (MIC)
WHITE
RED
250ohm 1.5mV
BALANCED
INPUT 2 (MIC)
NOTE: To change the INPUT Default Settings refer to the appropriate section in this Manual
INPUT 3 (MIC)
G COM HOT G COM HOT G COM HOT
3120 Micbal 01
TWO LEADS UNBALANCED MICROPHONE WIRING
VOX - MUTE JUMPERS SETTING
OFF
V1
VOX SEND
MIC IN
Input 1 - V1 - 01
MUTE RECEIVE
INPUT 1
V2
AUDIO OUT
M1
M2
OFF
MIC
Lo Z
SW215
JUMPER
JUMPER
SW220
JUMPER
X X
SHIELD
VOX 1 BUSS ACTIVATED
X
VOX 2 BUSS OFF
=
JUMPER
MUTE 1 BUSS OFF
MUTE 2 BUSS OFF
INPUT 1 - Default Jumper Settings
The Diagram at Left shows the Default Settings for INPUT 1.
VOX 1 is SWITCHED ON VOX 2 is SWITCHED OFF MUTE 1 is SWITCHED OFF MUTE 2 is SWITCHED OFF
When the INPUT 1 (MIC 1) is activated the VOX 1 BUSS is ON and it will MUTE any Input with the MUTE 1 Setting SWITCHED ON.
250ohm 1.5mV
INPUT 1 (MIC)
HOT LEAD
BALANCED
INPUT 2 (MIC)
NOTE: To change the INPUT Default Settings refer to the appropriate section in this Manual
INPUT 3 (MIC)
G COM HOT G COM HOT G COM HOT
3120 Micunbal 01
PAGE 11
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
INSTALLATION AND WIRING
USING A PUSH-TO-TALK DESK BASE MICROPHONE
Microphone paging and precedence over AUX 1 or AUX 2 channels may be accomplished by using a Desk Base or a Gooseneck Microphone.Wire the Microphone output leads to the MIC input ter­minals as per Fig. 11A.
MUTING: The Amplifier is equipped with two independent Muting Circuits:
z Direct Muting by shorting the MUTE Terminals
z
Automatic Muting with VOX - Voice Activated Muting
For additional information on the Muting operation refer to the Muting Functions section of this Manual.
WIRING
Fig. 11A - Input 1 and Muting Terminals
Wire the Desk Base Microphone leads to the Microphone Input terminal strip as per diagram in Fig 11A. Check Microphone instructions and connect HOT LEAD (B) to Ter minal HOT, COMMON LEAD (A) to Ter minal COM and SHIELD LEAD to Terminal G. Connect Muting Switch to Ter minals MUTE 1 or MUTE 2 and G as shown.
DO NOT GROUND THE MICROPHONE CABLE SHIELD TO THE CHASSIS OF THE AMPLIFIER
b50side
Push to Talk Key
Fig. 11 - Desk Base Microphone
INPUT 1 - USING A DESK BASE MICROPHONE
MUTING - PRIORITY SETTINGS
MUTING INPUT 4/AUX 1 (MUSIC INPUT)
T o m ute Input 4/A UX 1 (Music Input) when P aging from MIC 1, set INPUT 4/AUX 1 MUTE 1 JUMPER to ON Position. Each time MIC 1 is activated the Program on Input 4/AUX 1 is automatically muted by the VOX.
Direct Muting is provided by the Desk Base Muting Switch wired as per diagram in Fig. 11A. If Auto-Mute (VOX) is desired follow instruc­tions below.The Desk Base Muting Switch can be omitted.
CAUTION:
TO PREVENT POSSIBLE DAMAGE TO SPEAKERS OR THE AMPLIFIER ALL INPUT CONNECTIONS MUST BE MADE WITH THE AMPLIFIER POWER OFF.
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
Push to Talk Key
b50side
VOX - MUTE JUMPERS SETTING
V1
VOX SEND
MIC IN
Push to Talk Key
MUTE RECEIVE
Connect Desk Base or Gooseneck Microphone as per diagram below. Connect Muting Switch to MUTE 1 or MUTE 2 and G Terminals. If using the VOX system the muting switch is unnecessary.
V2
INPUT 1
DESK BASE/GOOSENECK MICROPHONE WITH MUTING SWITCH
INPUT 1 - Default Jumper Settings
The Diagram at Left shows the Default Settings for INPUT 1.
VOX 1 is SWITCHED ON VOX 2 is SWITCHED OFF MUTE 1 is SWITCHED OFF MUTE 2 is SWITCHED OFF
When the INPUT 1 (MIC 1) is activated the VOX 1 BUSS is ON and it will MUTE any Input with the MUTE 1 Setting SWITCHED ON.
250ohm 1.5mV
BALANCED
INPUT 2 (MIC)
NOTE: To change the INPUT Default Settings refer to the appropriate section in this Manual
OFF
AUDIO OUT
OFF
M1
X X
M2
SW215
VOX 1 BUSS ACTIVATED
JUMPER
X
VOX 2 BUSS OFF
=
JUMPER
SW220
JUMPER
MUTE 1 BUSS OFF
MUTE 2 BUSS OFF
MIC
Lo Z
MUTING SWITCH
MUTE 2
GROUND
GM2
SHIELD
MASTER REMOTE
MUTE 1
VOLUME
M1 RVC
RVC
INPUT 1 (MIC)
A
B
INPUT 3 (MIC)
G COM HOT G COM HOT G COM HOT
3120 Micbase 01
PAGE 12
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
INPUT CONNECTIONS
CONFIGURATION TABLES
CONDENSER AND ELECTRET TYPE MICROPHONES
Condenser and Electret Microphones require a DC Operating Voltage. The Amplifier provides this operating voltage or Phantom Power selectively on Inputs.1-2-3-4-5.
Prior to selecting the Condenser or Electret Microphone be sure that the Operating Voltage and Output Impedance of the device match the Input characteristics of the Amplifier listed below.
Phantom Power = 18 Volt DC Input Impedance = 250 to 600 ohm
ACCESS TO PHANTOM POWER SELECTORS
1) Remove Power Cord from AC Outlet.
2) Remove the three screws on each side of the Amplifier.
3) Lift Cover and carefully slide Cover out towards the rear.
4) Jumpers are located on the Main Printed Circuit Board.
Fig. 12 - Balanced Condenser/Electret Microphone Wiring - Configuration Tables
THE FOLLOWING INSTRUCTIONS REQUIRE THE REMOVAL OF THE AMPLIFIER PROTECTIVE COVER AND ARE PROVIDED FOR USE BY QUALIFIED PERSONNEL ONLY. TO AVOID THE RISK OF ELECTRICAL SHOCK DO NO T PERFORM ANY INSTALLA TION OR SERVICING UNLESS YOU ARE QUALIFIED TO DO SO. REFER INSTALLATION OR SERVICING TO QUALIFIED PERSONNEL.
CAUTION ! REMOVAL OF THE AMPLIFIER COVER PRESENTS AN ELECTRICAL SHOCK HAZARD
ALWAYS REMOVE THE POWER CORD FROM THE AC WALL OUTLET
CONDENSER AND ELECTRET MICROPHONES
WIRING
PHANTOM POWER SELECTOR JUMPER
By following the Main Printed Board Layout locate the Selector Jumpers with the ID No.as indicated on the Table below.
Reset the Phantom Pow er Jumpers for INPUT 1 - 2 or 3 to the ON position as desired. Lift the Mini Jumper out of the socket pins and re-position to the ON position. Make sure the Jumper is lined up with the socket pins.
INPUT 4 and 5 CONFIGURED AS MIC INPUTS If INPUT 4 and INPUT5 need to be configured as Microphone Inputs, reset the Phantom Power Jumpers as well as the Switches provided for the two Inputs as indicated in the Table below.
PHANTOM POWER SELECTORS
CONDENSER/ELECTRET MICROPHONE
Carefully follow the wiring instruction packed with the Microphone used. Attach the microphone leads to the terminal strip as per dia­gram per Fig. below.
DO NOT GROUND THE MICROPHONE CABLE SHIELD TO THE CHASSIS OF THE AMPLIFIER
®
TM
DIGITAL MUSIC AMPLIFIERS
PROFESSIONAL AUDIO & SOUND
DIGITAL MUSIC SERIES
BALANCED CONDENSER/ELECTRET MICROPHONE WIRING
MIC INPUTS PHANTOM POWER JUMPER SETTING
WHEN USING ELECTRET MICROPHONES
INPUT 1
On
JUMPER
OFF
SW201
INPUT 2
On
JUMPER
OFF
SW202
INPUT 3
On
JUMPER
OFF
SW203
INPUT 4
On
JUMPER
(When set as MIC 4)
OFF
SW204
INPUT 5
On
JUMPER
(When set as MIC 5)
OFF
SW207
SHIELD
MIC
Lo Z
INPUT 4 - 5 SWITCH SETTINGS WHEN
CONFIGURING AS MICROPHONE INPUT
Input Switch No. Setting
INPUT 4 SW228 MIC 4 INPUT 5 SW208 MIC 5 INPUT 5 SW229 MIC 5
INPUT 1 (MIC)
-0 +18V +18V
HOT LEAD HOT LEAD
INPUT 4 - 5 DEFAULT
SWITCH SETTINGS
Input Switch No. Setting
INPUT 4 SW228 AUX 1 INPUT 5 SW208 AUX 2 INPUT 5 SW229 AUX 2
250ohm 1.5mV
BALANCED
INPUT 2 (MIC)
INPUT 3 (MIC)
G COM HOT G COM HOT G COM HOT
INPUT 1- 2 - 3 - 4 - 5 DEFAULT
JUMPER SETTINGS
Input Jumper No. Setting
INPUT 1 SW201 OFF INPUT 2 SW202 OFF INPUT 3 SW203 OFF INPUT 4 SW204 OFF INPUT 5 SW207 OFF
3120 Micbal Electret
PAGE 13
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
Fig. 13A - Balanced Telephone Input Wiring
WIRING - The Amplifier is interface ready for the Telephone
line in applications requiring paging from the telephone sys­tem. The Telephone line Paging Output (Tip and Ring) can be directly connected to the TEL input and to the HOT and COM as shown in the wiring diagram Fig. 12A .
CABLE - Use a two conductor twisted wire. NOTE: The Telephone Paging Input is a Transformer
Balanced 600 ohm input.
DO NOT GROUND THE TIP OR RING WIRE TO THE CHASSIS OF THE AMPLIFIER
OUTPUT LEVEL CONTROL - Use TEL OUTPUT LEVEL
Control located on the Rear panel. After wiring adjust con­trol for the desired output level.
VOICE ACTIVATED MUTING (VOX) - Muting of the AUX 1 channel (music muting) during Paging is automatic via the Voice Activated Muting System. No contact closure for the Muting Circuit is required from the Telephone system. For additional information on the Muting operation refer to the Muting Functions section of this Manual.
PHONE PAGING PRIORITY OVER MICROPHONES -
Priority over any Microphone Input may be accomplished b y setting the MIC Inputs MUTE Jumpers.
INSTALLATION AND WIRING
Fig. 13 - Connecting to the Telephone Paging KSU
CAUTION:
TO PREVENT POSSIBLE DAMAGE TO SPEAKERS OR THE AMPLIFIER ALL INPUT CONNECTIONS MUST BE MADE
WITH THE AMPLIFIER OFF (POWER OFF).
P A GING FROM THE TELEPHONE SYSTEM
TELEPHONE SYSTEM PAGING WIRING
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
TM
DMS
DIGITAL MUSIC AMPLIFIER
DIGITAL MUSIC SERIES
100 100 100 100 100 100 +10-10 +10-10
INPUT 1 INPUT 2 INPUT 3 INPUT 4/AUX 1 INPUT 5/AUX 2 BASS TREBLEMODULE
DMS Amplifier
PROFESSIONAL AUDIO & SOUND
OUTPUT LEVEL
PEAK
TEL
POWER
O
Key Service Unit
KSU
Telephone
telpagin
BALANCED TELEPHONE PA GING WIRING
VOX - MUTE JUMPERS SETTING
SW214
OFF
VOX SEND
TEL IN
MUTE RECEIVE
V1
V2
TEL INPUT
Telephone System Paging Output
JUMPER
JUMPER
PAGING OUT
SW216
JUMPER
OFF
M1
X X
M2
VOX 1 BUSS ACTIVATED
X
VOX 2 BUSS OFF
=
JUMPER
MUTE 1 BUSS OFF
MUTE 2 BUSS OFF
TEL INPUT - Default Jumper Settings
The Diagram at Left shows the Default Settings for TEL INPUT.
VOX 1 is SWITCHED ON VOX 2 is SWITCHED OFF MUTE 1 is SWITCHED OFF MUTE 2 is SWITCHED OFF
When the TEL INPUT (PHONE) is activated the VOX 1 BUSS is ON and it will MUTE any Input with the MUTE 1 Setting SWITCHED ON.
TEL
G COM HOT
600 ohm 100 mV
BALANCED
NOTE: To change the
RING
INPUT Default Settings refer to the appropriate section in this Manual
TIP
3120 T elpaging 01
INPUT 4 SET AS AUX 1 (Reference. 19)
The AUX 1 input is provided for high level program source. The output from a Satellite Receiver, Tuner, Tape Cassette Deck, CD Player or other high level program source may be directly connected to this input.
AUX 1 SENSITIVITY ATTENUATOR (Reference. 18)
The AUX 1 Input is equipped with a Sensitivity Attenuator that allows the interface of the Input with Devices having a wide range of Output Levels.
TYPICAL OUTPUT LEVEL OF MUSIC DEVICES: Satellite Receivers = 1 to 5 Volt Digital T uners/Receivers = 100 to 300 Mv CD Players/Changers = 2 to 3 Volt Tape Decks = 500 to 700 Mv
By adjusting the Input Sensitivity to the level that matches the device used the correct interface with the Amplifier is achieved resulting in lower overall distortion and better fre­quency response characteristics.
SETTING THE AUX 1 INPUT ATTENUATOR
Connect a Music Source to the Amplifier. Turn Attenuator (rear panel) fully counterclockwise. Turn INPUT 4 Front Panel Control to midway. Switch Amplifier and Music Source ON. Turn Attenuator Control (rear panel) until desired Output Level is achieved. Adjust INPUT 4 Front Panel Level Control Up-Down as desired.
STEREO SUMMING
Most Music Source Devices provide a Stereo Output. Accordingly the Amplifier is equipped with two Jacks f or the AUX 1 Input (L and R). The two Inputs are internally buffered and electronically mixed to Mono. This system ensures that the Music Device is properly loaded and that the Stereo Signals are correctly summed (L+R) to Mono without distortion.
CABLE
To connect the music source devices to the AUX 1 Input use two single conductor shielded audio cable terminated in a single prong phono plug on both ends.
Fig. 14 - Rear Panel AUX 1 Input Diagram
AUX 1
AUX 1 INPUT MUTING
Fig. 14A - Stereo Summing and AUX 1 Input Attenuator
MUTING - WHEN MIC 1 OR THE TEL IN ARE ACTI-
VATED THE VOX 1 BUSS IS SWITCHED-ON AND THE SIGNAL PRESENT ON THE MUTE 1 BUSS WILL MUTE THE MUSIC FROM AUX 1.
SETTING INPUT 4 AS AUX 1 INPUT 4/AUX 1 DEFAULT SETTING
JUMPERS/SWITCH NO. FACTORY SETTING SW212 - VOX JUMPER = OFF
SW217 - MUTE JUMPER = M 1 SW228 - AUX1-MIC4 SWITCH = AUX 1
PAGE 14
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
INSTALLATION AND WIRING
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
DEFAULT JUMPERS AND SWITCH SETTING
SW212 = OFF SW217 = M 1 SW228 = AUX 1
MUSIC
IN
AUX 1 - MIC 4 SWITCH
SW228
AUX 1 MIC 4
18
AUX 1
ATTENUATOR
3120 Aux1 01
19
INPUT - 4 (AUX1)
47 kohm 100 mV
L
INPUT 4
AUX 1
Input 1-4 - V1 - 01
INPUT-5(AUX2)
47kohm 100mV
R
MUSIC OUTPUT
18
V1
V2
MUSIC OUT
L
(AUX2)
ATTENUATOR
R
INPUT 5
MIC-AUX2
BY INTERNAL
SWITCH
19
M1
M2
OFF
OFF
JUMPER
VOX 1 BUSS OFF
X X
VOX 2 BUSS OFF
SW212
WHEN MIC 1 IS ACTIVATED THE VOX 1 BUSS IS SWITCHED-ON AND THE SIGNAL PRESENT ON THE MUTE 1 BUSS WILL MUTE THE MUSIC FROM INPUT 4/AUX 1
SW217
MUTE 1 BUSS ON
JUMPER
X
MUTE 2 BUSS OFF
SATELLITE RECEIVER
AM/FM TUNER
CD PLAYER
CD
TAPE DECK
paso
TRACK 01
LR
TM
DIGITAL MUSIC SERIES
INPUT - 4 (AUX1)
47 kohm 100 mV
AUX 1
ATTENUATOR
3120 Stereo Summ
L
R
PAGE 15
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
INPUT 5 SET AS AUX 2 (Reference. 20)
The AUX 2 input is provided for high level program source. The output from a Jukebox, Tuner, Tape Cassette Deck, CD Player or other high level program source may be directly connected to this input.
AUX 2 SENSITIVITY ATTENUATOR (Reference. 21)
The AUX 2 Input is equipped with a Sensitivity Attenuator that allows the interface of the Input with Devices having a wide range of Output Levels.
TYPICAL OUTPUT LEVEL OF MUSIC DEVICES: Satellite Receivers = 1 to 5 Volt Digital T uners/Receivers = 100 to 300 Mv CD Players/Changers = 2 to 3 Volt Tape Decks = 500 to 700 Mv
By adjusting the Input Sensitivity to the level that matches the device used the correct interface with the Amplifier is achieved resulting in lower overall distortion and better fre­quency response characteristics.
SETTING THE AUX 2 INPUT ATTENUATOR
Connect a Music Source to the Amplifier. Turn Attenuator (rear panel) fully counterclockwise. Turn INPUT 5 Front Panel Control to midway. Switch Amplifier and Music Source ON. Turn Attenuator Control (rear panel) until desired Output Level is achieved. Adjust INPUT 5 Front Panel Level Control Up-Down as desired.
STEREO SUMMING
Most Music Source Devices provide a Stereo Output. Accordingly the Amplifier is equipped with two Jacks f or the AUX 1 Input (L and R). The two Inputs are internally buffered and electronically mixed to Mono. This system ensures that the Music Device is properly loaded and that the Stereo Signals are correctly summed (L+R) to Mono without distortion.
CABLE
To connect the music source devices to the AUX 1 Input use two single conductor shielded audio cable terminated in a single prong phono plug on both ends.
Fig. 15 - Rear Panel AUX 2 Input Diagram
AUX 2
AUX 2 INPUT MUTING
Fig. 15A - Stereo Summing and AUX 2 Input Attenuator
MUTING - WHEN MIC 1 OR THE TEL IN ARE ACTI-
VATED THE VOX 1 BUSS IS SWITCHED-ON AND THE SIGNAL PRESENT ON THE MUTE 1 BUSS WILL MUTE THE MUSIC FROM AUX 2.
SETTING INPUT 5 AS AUX 2 INPUT 5/AUX 2 DEFAULT SETTING
JUMPERS/SWITCH NO. FACTORY SETTING SW213 - VOX JUMPER = OFF
SW223 - MUTE JUMPER = M 1 SW208 - AUX 2-MIC 5 SWITCH = AUX 2 SW229 - AUX 2-MIC 5 SWITCH = AUX 2
INSTALLATION AND WIRING
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
DEFAULT JUMPERS AND SWITCH SETTING
SW213 = OFF SW223 = M 1 SW208 = AUX 2 SW229 = AUX 2
MUSIC
IN
AUX 2 - MIC 5 SWITCH
SW208 and SW229
AUX 2 MIC 5
SET TO AUX 2
20
INPUT - 4 (AUX1)
47 kohm 100 mV
AUX 1
ATTENUATOR
3120 Aux2 01
L
R
V1
V2
INPUT 5
AUX 2
Input 1-4 - V1 - 01
21
INPUT 5 (AUX 2) 47 Kohm 100 mV
L
R
(AUX 2)
ATTENUATOR
INPUT 5
MIC-AUX2
BY INTERNAL
SWITCH
MUSIC OUTPUT
JUMPER
OFF
SW213
MUSIC OUT
SW223
OFF
M1
JUMPER
X
M2
VOX 1 BUSS OFF
X X
VOX 2 BUSS OFF
WHEN MIC 1 IS ACTIVATED THE VOX 1 BUSS IS SWITCHED-ON AND THE SIGNAL PRESENT ON THE MUTE 1 BUSS WILL MUTE THE MUSIC FROM INPUT 5/AUX 2
MUTE 1 BUSS ON
MUTE 2 BUSS OFF
SATELLITE RECEIVER
paso
AM/FM TUNER
TRACK 01
CD PLAYER
CD
TAPE DECK
LR
TM
DIGITAL MUSIC SERIES
20
3120 Stereo Summ 01
21
INPUT 5 (AUX 2) 47 Kohm 100 mV
L
ATTENUATOR
R
(AUX 2)
INPUT 5
MIC-AUX2
PAGE 16
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
ADDRESSABLE DUAL VOX SYSTEM
DUAL VOX - VOICE ACTIVATED MUTING - The Amplifier is equipped with a DUAL noiseless, fast acting Logic VOX Switching System. When any of the INPUTS are activated and a Signal is present on a given INPUT and either VOX 1 or VOX 2 or BOTH are Switched-ON (using internal Jumpers) then the MUTE 1 or MUTE 2 BUSS or BOTH are ACTIVE. If any of the INPUTS have the MUTE 1 or MUTE 2 Switched-ON (by Internal Jumpers) then the INPUT (or INPUTS) will be MUTED according to the Jumpers Setting. Once the SIGNAL-ON on the ACTIVE INPUT is terminated the normal functions are automatically restored on all muted inputs.
ACCESS T O VO X AND MUTE JUMPERS
REFER TO JUMPERS AND SWITCHES INTERNAL ACCESS.
CAUTION:PRIOR TO PERFORMING THE ABOVE OPER­ATION BE SURE TO FOLLOW THE SAFETY NOTES REFERRING TO THE REMOVAL OF THE AMPLIFIER COVER.
Fig. 16 - Rear Panel VOX 1 and VOX 2 Sensitivity Control
and MUTE 2 Delay Control
VOX - VOICE ACTIVATED MUTING
VOX SENSITIVITY CONTROLS
VOX SENSITIVITY ADJUSTMENT
1) Turn all Front Panel Input Level Controls to 0.
2) Turn VOX Sensitivity Control counterclockwise until it stops.
3) Connect a Signal Source (Microphone, Telephone or Music) to the respective Input Terminals (For connection details refer to the appropriate section in this Manual).
4) While talking from a Paging Source (Microphone or Telephone) or Playing Music rotate the INPUT LEVEL CON­TROLS (Front Panel) until the desired output level is achieved.
5) While talking from a Paging Source (Microphone or Telephone) or Playing Music, turn the Sensitivity Control (VOX 1 or VOX 2) slowly clockwise until the Muting (MUTE 1 or MUTE 2) is activated.
VOX JUMPERS DEFAULT SETTING TABLE
SW210 INPUT 2 - VOX1 - VOX2 - OFF OFF SW211 INPUT 3 - VOX1 - VOX2 - OFF OFF SW212 INPUT 4 - VOX1 - VOX2 - OFF OFF SW213 INPUT 5 - VOX1 - VOX2 - OFF OFF SW214 TEL IN - VOX1 - VOX2 - OFF V1 SW215 INPUT 1 - VOX1 - VOX2 - OFF V1 SW221 MODULE - VOX1 - VOX2 - OFF OFF
JUMPER JUMPER FUNCTION FACTORY FACTORY
ID NO. REFERENCE DESCRIPTION SETTING SETTING
MAIN PCB JUMPERS
VOX SENSITIVITY CONTROLS
VOX 1 AND VOX 2 SENSITIVITY CONTROLS
The VOX 1 and VOX 2 Sensitivity Controls set the sensitiv­ity level at which point the VOX 1 and VOX 2 are respective­ly engaged during INPUT ACTIV ATION.The VO X Sensitivity Controls are located on the Amplifier Rear Panel.
VOX 1 SENSITIVITY CONTROL = Reference 33 VOX 2 SENSITIVITY CONTROL = Reference 32
VOX SENSITIVITY ADJUSTMENT
INSTALLATION AND WIRING
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
VOX-2 MUTE-2
VOX-1
SENS
SENS
DELAY
313233
DMS3120 Vox Sens 01
PAGE 17
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
ADDRESSABLE DUAL MUTING SYSTEM
DIRECT MUTING - Direct Muting may be accomplished by short­ing the MUTE 1 and MUTE 2 Terminals to the G Terminal through an external switch.Each time the Muting Switch is closed the cor­responding MUTE BUSS is activated.
Fig. 17 - Direct Muting Terminals and Diagram
DIRECT MUTING
WIRING
Fig. 17B - M 1 Function Timing Diagram
MUTING TIMING - The MUTING is preset f or -60 db Attenuation.
When MUTE 1 or 2 are activated the MUTE BUSS is instanta­neously Switched-ON. When the Muting is deactivated the pro­gram source is gradually restored.
MUTE 1 (M1) = TIMING PRESET 2-3 SECONDS MUTE 2 (M2) = TIMING ADJUSTABLE 3-30 SECONDS MUTE 2 DELA Y = USE REAR PANEL CONTROL Reference 31
INSTALLATION AND WIRING
MUTE JUMPERS DEFAULT SETTING TABLE
SW206 VOX RELAY - MUTE 1 - MUTE 2 M1 SW216 TEL IN - MUTE 1 - MUTE 2 - OFF OFF SW217 INPUT 4/AUX 1 - MUTE 1 - MUTE 2 - OFF M1 SW218 INPUT 3 - MUTE 1 - MUTE 2 - OFF OFF SW219 INPUT 2 - MUTE 1 - MUTE 2 - OFF OFF SW220 INPUT 1 - MUTE 1 - MUTE 2 - OFF OFF SW222 MODULE - MUTE 1 - MUTE 2 - OFF OFF SW223 INPUT 5/AUX 2 - MUTE 1 - MUTE 2 - OFF M1 SW227 CHIME TRIGGER - MUTE 1 - MUTE 2 M1
JUMPER JUMPER FUNCTION FACTORY FACTORY
ID NO. REFERENCE DESCRIPTION SETTING SETTING
MAIN PCB JUMPERS
DUAL MUTING SYSTEM - The Amplifier is equipped with a DUAL
noiseless, fast acting Logic MUTING Switching System.When any of the INPUTS are activated and a Signal is present on a given INPUT and either VOX 1 or VOX 2 or BOTH are Switched-ON (using internal Jumpers) then the MUTE 1 or MUTE 2 BUSS or BOTH are ACTIVE. If any of the INPUTS have the MUTE 1 or MUTE 2 Switched-ON (by Internal Jumpers) then the INPUT (or INPUTS) will be MUTED according to the Jumpers Setting. Once the SIGNAL-ON on the ACTIVE INPUT is terminated the normal functions are automatically restored on all muted inputs.
ACCESS T O MUTE JUMPERS
REFER TO JUMPERS AND SWITCHES INTERNAL ACCESS. CAUTION: PRIOR TO PERFORMING THE ABOVE OPERATION
BE SURE TO FOLLOW THE SAFETY NOTES REFERRING TO THE REMOVAL OF THE AMPLIFIER COVER.
Fig. 17C - M 2 Function Timing Diagram
MUTE 2 DELAY - The M 2 Delay can be adjusted by using the
MUTE 2 DELAY CONTROL
on the rear panel (reference 31).
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
10
MASTER REMOTE
MUTE 1
VOLUME
MUTE 2
MUTE-2
DELAY
GROUND
GM2
M1 RVC
RVC
31
MUTING SWITCH M 2
3120 M1 - M2 01
MUTING SWITCH M 1
Signal
Level
DMS mutfunct 01
MUTE 1
Program
Attenuation
60 dB
Terminals
shorted
Program
2-3
gradually
sec.
restored
Mute terminals
opened
time
Signal
Level
DMS mutfunct 02
MUTE 2
Program
Attenuation
60 dB
Terminals
shorted
Adjustable
from
3 to 30
seconds
Mute terminals
opened
Program
gradually
restored
time
PAGE 18
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
INSTALLATION AND WIRING
INPUT 1 (MIC 1) UNMUTING FUNCTION
The Input 1 (MIC 1) can be preset to be normally MUTED (INPUT OFF) when the JUMPER SW205 - MIC 1 UNMUTE - IS SET TO
THE ON POSITION. The MIC 1 is SWITCHED-ON when the UNMUTE and G Terminals are shorted by a Switch Contact
Closure.This function allows for a multi zone installation using two or more Amplifiers and a single Microphone and Zone Switches. When the Jumper SW205 is set to the ON Position the Microphone Input is OFF and it is turned ON when the UNMUTE and the G ter­minals are closed by a switch.
JUMPER NO. FUNCTION POSITION SET SW205 MIC 1 Muted ON
If the Jumper requires resetting follow the instruction below.
ACCESS TO UNMUTING JUMPER
1) Remove Power Cord from AC Outlet.
2) Remove the three screws on each side of the Amplifier securing the Top Cover to the Chassis.
3) Lift Cover and carefully and slide Cover out towards the rear.
4) On the Main Amplifier Printed Board locate the SW205 ­MIC 1 UNMUTE Jumper Set.
5) Set Jumper to the ON position.
Fig. 18 - Microphone and Zone Unmuting Diagram
THE FOLLOWING INSTRUCTIONS REQUIRE THE REMOVAL OF THE AMPLIFIER PROTECTIVE COVER AND ARE PROVIDED FOR USE BY QUALIFIED PERSONNEL ONLY. TO AVOID THE RISK OF ELECTRICAL SHOCK DO NOT PERFORM ANY INSTALLA­TION OR SERVICING UNLESS YOU ARE QUALIFIED TO DO SO.
CAUTION !
REMOVAL OF THE AMPLIFIER COVER PRESENTS AN ELECTRICAL SHOCK HAZARD
ALWAYS REMOVE THE POWER CORD FROM THE AC WALL OUTLET
DIRECT UNMUTING
WIRING
Fig. 18A - 2 - Zone System Jumper Settings
Fig. 18B - 2 - Zone Switching Panel
INPUT 1 (MIC 1) UNMUTING FUNCTION
The Fig. at right shows a typical 2 Zone Switching Panel. Use SPST Momentary Contact Switches. See complete 2 - Zone Wiring Diagram provided in this Manual.
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
MUTE 2
M1 RVC
MASTER REMOTE
MUTE 1
VOLUME
RVC
SHIELD
2 - ZONE
PAGING SELECTORS
Connect Paging Microphone as per diagram below (reference 30). Connect Zone Unmuting Switch to UNMUTE (reference 9) and G Terminals. The VOX (if ON) feature will automatically mute the Music
30
250ohm 1.5mV
INPUT 1 (MIC)
A
BALANCED
INPUT 2 (MIC)
G COM HOT G COM HOT
A = Common B = Hot
B
3120 Unmute 01
21
UNMUTE - VOX AND MUTE JUMPER
SETTINGS ON AMPLIFIERS 1 & 2
MICROPHONE WITH UNMUTING ZONE SWITCH
9
GROUND
UNMUTE
MIC1 G M2
ZONE UNMUTING SWITCH
MIC
Lo Z
INPUT 1
OFF
V1 V2
MIC 1
JUMPER
VOX 1 ON
UNMUTE
On
MIC 1
JUMPER
SW205
OFF
SW215
3120 Unmute Jump Set
OFF
INPUT 4
M1 M2
SW217
AUX 1
JUMPER
MUTE 1 ON
TO AMP 1
TO AMP 2
3120 2 Zone Diagram 01
TO MIC INPUT
SPST ZONE
SWITCHES
ZONE 1
ZONE 2
PAGING MICROPHONE
PAGE 19
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
INSTALLATION AND WIRING
OPERATION - A 2 - Zone Paging Wiring Diagram Application is provided.The Paging Microphone is connected in parallel to all the Microphone Inputs.Two
Independent SPST Switches are provided for the Paging Zone Selection. MUSIC - The MUSIC SOURCE (Satellite Receiver) is cascade connected to the
two Amplifiers.ZONE PAGING - When one or more Zone Switches are activated the UNMUTE Function OPENS the Microphone Channel on the Amplifier
selected and the MICROPHONE is active for the PAGING. Simultaneously the MUSIC is MUTED ONLY ON THE ZONE (OR ZONES) SELECTED.
Independent MUSIC SOURCE may be provided to each of the Amplifiers if required.MOH - MUSIC ON HOLD is available from each of the Amplifiers used.
The MOH source maybe selected from either the AUX 1, AUX 2 or the MODULE Input and is immune to Paging or the MUTE/UNMUTE Function.
2 ZONE PAGING AND MUSIC WIRING DIAGRAM
Fig. 19 - 2 Zone Paging and Music System
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
SELECTORS
2 ZONE PAGING
Paging Microphone can be
Unswitched and always ON
PAGING MICROPHONE
SATELLITE RECEIVER
MUSIC SOURCE LINE
UNMUTE
GROUND
L
47kohm 100mV
INPUT-5(AUX2)
INPUT-4(AUX1)
47kohm 100mV
MIX
BUSS
PRE EQ
SUB OUT
PRE
OUT
30TJ
AUDIO
LISTED
EQUIPMENT
COMMERCIAL
CUS
RVC
MASTER
REMOTE
VOLUME MUTE 1
M1 RVC
MUTE 2
GROUND
UNMUTE
MIC1 G M2
24V DC
250 mA
+-
VOX RELAY
NC C NO
ZONE 2
(AUX2)
ATTENUATOR
(AUX1)
ATTENUATOR
EQ LINK
LEVEL
MUSIC OUTPUT
MODULE
STANDARD
PORT ACCEPTS
R
INPUT 5
MIC-AUX 2
BY INTERNAL
OFF
TONE
BYPASS
AUX2
ON
600
INPUT 4
LINE OUT
SUB OUT
POST EQ
IN
POWER
EQ LINK
IN OUT
DO NOT OPEN
CAUTION
RISK OF ELECTRIC SHOCK
WARNING: THIS APPLIANCE
120 W RMS
DMS3120
DIGITAL MUSIC AMPLIFIER
PROFESSIONAL AUDIO & SOUND
POWER RATING
CAUTION: REMOVE
TEL OUTPUT
SWITCH
TEL
G COM HOT
47Kohm 100 mV
INPUT5 (MIC-AUX2)
VOLUME
REMOTE
G COM HOT RVC RVC G COM HOT G COM HOT G COM HOT G COM HOT
INPUT 4 (MIC) INPUT 3 (MIC)
INPUT 2 (MIC)
MUST BE EARTHED
INPUT 1 (MIC)
850 VA
117V 60 HZ
VOX-2 MUTE-2
SUPPLY VOLT A GE
POWER CONSUMPTION
VOX-1
POWER CORD FROM
AC OUTLET PRIOR TO
INSTALLING MODULE
LEVEL
DELAY
SENS
SENS
600 ohm 100mV
BALANCED
250ohm 1.5mV
SER. NO.
HOT
COMMON
MICROPHONE WIRE
GROUND (SHIELD)
MUSIC SOURCE LINE
25V/70V Speaker
2 Conductor Shielded
UNMUTE
21
INPUT-5(AUX2)
INPUT-4(AUX1)
MIX
SUB OUT
PRE
LISTED
GROUND
MASTER
MUTE 1 ON
JUMPER
L
47kohm 100mV
47kohm 100mV
BUSS
PRE EQ
OUT
30TJ
AUDIO
EQUIPMENT
COMMERCIAL
CUS
RVC
REMOTE
VOLUME
MUTE 1
M1 RVC
MUTE 2
GROUND
UNMUTE
MIC1 G M2
24V DC
250 mA
+-
VOX RELAY
NC C NO
ZONE 2
ZONE 2
ZONE 1
SPST
SWITCHES
PORT ACCEPTS
(AUX2)
ATTENUATOR
R
(AUX1)
ATTENUATOR
OFF
ON
EQ LINK
IN OUT
LEVEL
MODULE
STANDARD
CAUTION: REMOVE
POWER CORD FROM
LEVEL
TEL OUTPUT
INPUT 5
SWITCH
MIC-AUX 2
BY INTERNAL
TEL
G COM HOT
TONE
BYPASS
AUX2
47Kohm 100 mV
INPUT5 (MIC-AUX2)
600
INPUT 4
LINE OUT
VOLUME
REMOTE
SUB OUT
POST EQ
G COM HOT RVC RVC G COM HOT G COM HOT G COM HOT G COM HOT
INPUT 4 (MIC) INPUT 3 (MIC)
IN
POWER
EQ LINK
INPUT 2 (MIC)
DO NOT OPEN
CAUTION
RISK OF ELECTRIC SHOCK
MUST BE EARTHED
INPUT 1 (MIC)
WARNING: THIS APPLIANCE
850 VA
120 W RMS
117V 60 HZ
DMS3120
VOX-2 MUTE-2
DIGITAL MUSIC AMPLIFIER
PROFESSIONAL AUDIO & SOUND
POWER RATING
SUPPLY VOLT A GE
POWER CONSUMPTION
VOX-1
AUX 1
INPUT 4
MIC 1
UNMUTE
JUMPERS SETTING
ON AMPLIFIERS 1 & 2
MIC 1
INPUT 1
AC OUTLET PRIOR TO
INSTALLING MODULE
3120 2 Zone Diagram
600 ohm 100mV
BALANCED
250ohm 1.5mV
DELAY
SENS
SENS
SER. NO.
OFF
JUMPER
On
OFF
OFF
M1
SW205
JUMPER
V1
SW217
M2
VOX 1 ON
SW215
V2
25V/70V Speaker
0 8
ZONE 2
1 WATT
0 8
ZONE 1
0 600
AFIN DE REDUIRE LE RISQUE
LEVEL
ZONE 1
D'INCENDIE REMPLACER SEUL PAR UN
FUSIBLE DE MEME TYPE.
ATTENTION:
CAUTION: TO REDUCE THE
RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE
FUSE.
1 WATT
ATTENTION: POUR REDUIRLES RISQUES D' INCENDIE
OU DE CHOC ELECTRIQUE, NE PAS EXPOSER A LA PLUIE
OU L' HUMIDITE, NE PAS ENLEVER LE COUVERCLE. AUCUN
REGLAGE A L' INTERIEUR. POUR REPARATION CONSULTER
UNE PERSONNE QUALIFIEE
BALANCED
MOH OUT
CAUTION: TO REDUCE THE RISK OF FIRE OR
SHOCK DO NOT EXPOSE THIS APPLIANCE TO
RAIN OR MOISTURE. DO NOT REMOVE COVER.
THERE ARE NO USER SERVICEABLE PARTS
117V 500W MAX
SPEAKER OUTPUT
COM 8 25V 70V
GROUND
INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
5A 250V
LINE FUSE
UNSWITCHED
117V 60HZ
ZONE 1
25V/70V Speaker 25V/70V Speaker
0 8
ZONE 2
1 WATT
0 8
1 WATT
ZONE 1
0 600
MOH OUT
AFIN DE REDUIRE LE RISQUE
LEVEL
ZONE 1
D'INCENDIE REMPLACER SEUL PAR UN
FUSIBLE DE MEME TYPE.
ATTENTION:
CAUTION: TO REDUCE THE
RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE
FUSE.
ATTENTION: POUR REDUIRLES RISQUES D' INCENDIE
OU DE CHOC ELECTRIQUE, NE PAS EXPOSER A LA PLUIE
OU L' HUMIDITE, NE PAS ENLEVER LE COUVERCLE. AUCUN
REGLAGE A L' INTERIEUR. POUR REPARATION CONSULTER
UNE PERSONNE QUALIFIEE
COM 8 25V 70V
BALANCED
GROUND
CAUTION: TO REDUCE THE RISK OF FIRE OR
SHOCK DO NOT EXPOSE THIS APPLIANCE TO
RAIN OR MOISTURE. DO NOT REMOVE COVER.
THERE ARE NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
LINE FUSE
UNSWITCHED
117V 500W MAX
117V 60HZ
SPEAKER OUTPUT
5A 250V
ZONE 2
25V/70V Speaker 25V/70V Speaker
PAGE 20
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
INSTALLATION AND WIRING
CONNECTING TO AN EXTERNAL EQUALIZER
The Amplifier is equipped with an External Equalizer Link to allows the use of an External Equalizer for applications requiring
Frequency Selective Acoustic Correction
. The Amplifier is furnished with the two jacks of the Link bridged by a SELECTOR SWITCH. When the EQ LINK Switch (REFERENCE 12) is the IN position the internal Preamplifier to Amplifier Link (Reference 13) is broken allowing the insertion of an External Equalizer.
INST ALLA TION TIPS
1) Use high quality, short length audio cables and position the Equalizer in close proximity to the Amplifier. Avoid mounting the EQ on top of the Amplifier unless is Rack mounted.
2) Be sure that the Amplifier input controls and the EQ level control are set at zero prior to turning the system On.
3) The Amplifier TONE BY PASS SWITCH (Reference 17) should be set to ON ( linear response position).
4) Carefully adjust the EQ Level Control to avoid distortion caused by excessive signal boost.
5) Follow the instructions supplied with the Equalizer.
WIRING
To connect to an External Equalizer use two (2) single con­ductor shielded audio cables terminated in a single prong phono plug on both ends.
SET EQ LINK SWITCH TO IN
EXTERNAL EQUALIZER LINK
Fig. 20 - Rear Panel External Equalizer Link Diagram
MIX BUSS BRIDGING
Fig. 20B - Rear Panel Mix Buss Bridging Diagram
BRIDGING TWO AMPLIFIERS
The MIX BUSS (Reference 15) allows two Amplifiers to be bridged and share all inputs.
All signal sources connected to all the inputs are common to the output of both amplifiers. Muting and level controls operate in exactly the same way as if only one amplifier was used.
MIX BUSS BRIDGING
WIRING
CABLE
To bridge two amplifiers or to con­nect to an external Mixer use a sin­gle conductor shielded audio cable terminated in a single prong phono plug on both ends.
SET TONE BY PASS SWITCH TO
ON
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
13
EXTERNAL EQUALIZER
12
PRE OUT
EQ LINK
IN OUT
EQ LINK
POWER
IN
To Input of Equalizer
To Output of Equalizer
3120 EQlink
17
paso
ON OFF
TONE
BYPASS
AMPLIFIER A
15
MIX
BUSS
LINE OUT
600
ON
3120 Mixbuss
15
AMPLIFIER B
MIX
BUSS
ON
LINE OUT
600
PAGE 21
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
INSTALLATION AND WIRING
MASTER REMOTE VOLUME
Fig. 21 - Master Remote Volume Control Diagram
REMOTE V OLUME CONTROLS
The Amplifier features two independent Remote Volume Control Capability:The INPUT 4 (AUX 1) Remote Volume (Reference 26) and the MASTER REMOTE VOLUME CONTROL (Reference 11). A 10 K ohm Potentiometer is required for either control. Mount the 10 K Pot on a suitable Wall Plate or any other convenient surface and connect to the Amplifier RVC Terminals as shown in the Diagram. The Paso Model RVC10W Decora Style Remote Volume Control may be used.
INPUT 4 (AUX 1) OPERATION
When connected the Remote Volume adjusts the INPUT 4 (AUX 1) Level only.Usually this input is utilized for the Music Source (Satellite Receiver, CD Player, etc.).
MASTER VOLUME OPERATION
The Control is a Master Volume and controls all the Inputs of the Amplifier with the exception of the MOH and ZONE 1 and ZONE 2 Outputs.
CABLE
To connect the Remote Control to the Amplifier use a two conductor wire not less than A WG 24.While the Remote Volume System uses DC rather than audio caution should be exercised in the la y out of the wire .Always avoid routing next to pow er lines.If the total wire resist­ance exceeds 3 K ohm the Volume may not go down to zero.
REMOTE VOLUME CONTROL - OPTIONAL ACCESSORY
MODEL RVC10W REMOTE VOLUME CONTROL
Remote Volume Control Potentiometer. Single Gang Decora Style Plate.
SPECIFICATIONS
Control: 10 K ohm High Quality Control. Connection: 6” Two Wire, color coded (Black and Red) Pigtails stripped and tinned. Color Finish: White. Dimensions: Front Plate = 4.5” High, 2.75” Wide. Depth: 0.5”. Mounting Hardware: Supplied.
INPUT 4 (AUX 1) REMOTE VOLUME
Fig. 21B - Input 4 Remote Volume Control Diagram
Fig. 21C - RVC10W Front View Fig. 21D - RVC10W Rear View
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
11
MASTER
REMOTE V OLUME
CONTROL 10 K ohm
POTENTIOMETER
MASTER REMOTE VOLUME
RVC
RVC
26
INPUT 4 (AUX 1)
REMOTE V OLUME
CONTROL 10 K ohm
POTENTIOMETER
INPUT 4 REMOTE VOLUME
RVC
RVC
Paso Remote
Volume Control
3120 Remote Volume
RVC10W
PAGE 22
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
INSTALLATION AND WIRING
MODULE TYPE
The Amplifier accepts Audio Modules having a 6 Contact PCB Derivation.Module mounting panel should be 3” H., 1-3/8” W. (
78 X 35 mm
).
INSTALLATION
CAUTION: REMOVE POWER CORD FROM AC OUTLET PRIOR TO INSTALLING A MODULE. BE SURE THAT THE MODULE OUTPUT LEVEL CONTROL IS SET AT “0” PRIOR TO THE INST ALLATION.
1) Locate Rear Panel Module Port (Reference 22) and unscre w the two crosshead scre ws holding the cov er and set aside.
2) Reach inside the Amplifier and gently pull-out the Module Blue Ribbon Connector. If the Connector is tied to the chas­sis remove the Amplifier Top Cover and with a cutter cut the Nylon Tie holding the connector.
NOTE: BE CAREFUL NOT TO CUT THE CONNECTOR WIRE HARNESS.
3) Pull-out the blue-ribbon connector through the port opening (do not pull-out wire har ness excessively).
4) By keeping the connector gold contacts on the left insert the Module PCB contacts into the socket.
5) Push Module through por t opening and secure to rear panel by using the two screws removed with the Module cover.
MODULE INSTALLATION
INSTALLING A MODULE
Fig. 22 - Rear Panel Module Installation Diagram
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
22
TM
DIGITAL MUSIC SERIES
RVC
WARNING: THIS APPLIANCE
MUST BE EARTHED
INPUT 2 (MIC)
Insert into Module Connector
Printed Board Copper Side
LISTED
COMMERCIAL
AUDIO
EQUIPMENT
30TJ
CUS
EQ LINK
IN OUT
EQ LINK
SUB OUT
PRE EQ
SUB OUT POST EQ
MIX
BUSS
LINE OUT
600
INPUT 4 REMOTE VOLUME
Gold
Contact
ON
TONE
BYPASS
AUX2 47Kohm 100 mV INPUT5 (MIC-AUX2)
PRE OUT
POWER
IN
INPUT 4 (MIC) INPUT 3 (MIC) G COM HOT RVC RVC G COM HOT G COM HOT G COM HOT
250ohm 1.5mV
BALANCED
Side
View
INPUT-4(AUX1) 47kohm 100mV
(AUX1)
ATTENUATOR
OFF
Connector
Top
Front View
TEL
G COM HOT
600 ohm 100mV
INPUT-5(AUX2) 47kohm 100mV
L
(AUX2)
ATTENUATOR
R
INPUT 5
MIC-AUX 2
BY INTERNAL
SWITCH
TEL OUTPUT
3120 Module Install
LEVEL
Cable from
Amplifier
PORT ACCEPTS
STANDARD
MODULE
CAUTION: REMOVE POWER CORD FROM AC OUTLET PRIOR TO INSTALLING MODULE
Module Bottom
Module Gold
Contacts
PAGE 23
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
INSTALLATION AND WIRING
MODULE CONNECTOR DIAGRAM
Fig. 23 - Module Connector Contacts Diagram
MODULE CONNECTOR DIAGRAM - The above Diagram indicates the function of each of the six contacts of the Module
Connector. The Module Blue Ribbon Connector is attached to a wire harness and left floating beyond the Module Port Cover.The Wire Harness Amplifier End is attached to Connector No.CN201 and plugged into the mating connector on the Main Printed Circuit Board.
MODULE DEFAULT SETTINGS
Fig. 23A - Module VOX - MUTE - INPUT SOURCE Default Settings
MODULE FUNCTIONS - The Module Port accepts a stan-
dard audio Module.When a Module is utilized several func­tions can be activated by the Jumpers and Switch provided for this Input.
VOX SEND - The SW221 Jumpers Set activates the VOX 1
- VOX 2 SEND or both. When a Signal is present at the Module Output (Contact 4) then the V OX BUSS selected will be active.
MUTE RECEIVE - The SW222 Jumpers Set activates the
MUTE 1 - MUTE 2 RECEIVE or both.When a Signal is pres­ent at the MUTE BUSS 1 or MUTE BUSS 2 the MODULE will be MUTED accordingly.
INPUT SOURCE - The SW209 Switch selectes the Input Source for the Module either AUX 1 or AUX 2. The Signal present at either Input will be sent to the MODULE INPUT (Contact 5).
By selecting the proper Setting several functions can be derived from the Module.
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
Connector
6 5 4 3 2 1
MODULE CONNECTOR
Top
Front View
Gold
Contact
PCB
CONNECTOR
CN201
TO
MODULE
3120 Module Schem
6 5 3 4 3 2
1
Side View
6 5 4 3 2 1
Cable from
Amplifier
TM
DIGITAL MUSIC SERIES
Connector Contacts
6 = + 24V DC 5 = Module Input 4 = Module Output 3 = Ground 2 = Mute Buss 1 1 = Mute Buss 2
MODULE CONNECTOR
Connector
Top
6 5 4 3 2 1
Front
View
3120 Module Functions
Gold
Contact
Side View
PCB
CONNECTOR
6 5 4 3 2 1
Connector Contacts 6 = + 24V DC 5 = Module Input 4 = Module Output 3 = Ground 2 = Mute Buss 1 1 = Mute Buss 2
Cable from
Amplifier
CN201
TO
MODULE
6 5 3 4 3 2
1
VOX SEND
MODULE OUTPUT
MUTE RECEIVE
MODULE VOX - MUTE
JUMPERS AND INPUT SOURCE
SWITCH DEFAULT SETTING
JUMPER
V1
V2
MODULE INPUT
M1
M2
OFF
OFF
VOX 1 BUSS OFF
X X
VOX 2 BUSS OFF
SW221
AUX 1 - AUX 2 SWITCH
SW209
AUX 1 AUX 2
JUMPER
MUTE 1 BUSS OFF
X X
MUTE 2 BUSS OFF
SW222
AUX 1 SOURCE
AUX 2 SOURCE
PAGE 24
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
INSTALLATION AND WIRING
Fig. 24 - Rear Panel View - ZONE 1 - ZONE 2 - MOH Outputs - Source Selectors and Controls
ZONE 1 MOH AND 8 OHM OUTPUTS MOH - ZONE1 & 2 AMPLIFIER FUNCTIONS
MOH AMPLIFIER
a) The MOH Amplifier can receive programs from AUX
1 - AUX 2 and the MODULE.
b) Selection of the input source is by Internal Jumper. c) The ZONE 1 independent 600 Ohm and 8 Ohm
Outputs may be used simultaneously.
d) The MOH 600 ohm Output is Transformer Balanced. e) The Rear Panel ZONE 1 Level Control operates both
the 600 Ohm and 8 Ohm Outputs simultaneously.
MOH AND ZONE 1-2 OPERATION ISSUES
1) Paging from the Microphone Inputs or the Telephone
Input does not effect the MOH/ZONE 1-2 Amplifier.
2) Position of the INPUTS Level Control does not affect the MOH/ZONE 1-2 Amplifier Output Level.
3) P osition of the AUX 1 and AUX 2 ATTENUATOR does not affect the MOH/ZONE 1-2 Amplifier Output Level.
4) Muting activation of M1 or M2 Buss (from Microphones or Telephone) does not effect the Output of the MOH/ZONE 1­2 Amplifier except if the INPUT SOURCE is set to MODULE and the Module Output is Muted. See Module Settings.
ZONE 1 OUTPUTS
The DMS Amplifier is equipped with two 1 Watt, 8 ohm Amplifiers and a separate 600 ohm MUSIC ON HOLD AMPLIFIER.
600 Ohm MOH - The MOH Output provides a 600 ohm, 1 Volt Transformer Balanced Output (Reference 3).
1 WATT, 8 Ohm - Simultaneously a Second Zone 8 ohm, 1 Watt Output may be utilized to drive up to 4 Speakers (Reference 4).
OUTPUT LEVEL CONTROL - A Level Control for both the 600 ohm Output and the 1 Watt Output is provided (Reference 2)
MOH AND 8 Ohm AMPLIFIER INPUT SOURCE SELECTION
The program source for the Input of the 600 ohm MOH Output and the 8 ohm Output can be selected from either AUX 1 - AUX 2 or the MODULE source. Set the Jumpers Set No.SW 702 to desired position. Default setting is AUX 1.
ZONE 2 OUTPUT 1 WATT, 8 Ohm - A Second Zone 8 ohm, 1 Watt Output may be
utilized to drive up to 4 Speakers (Reference 5). OUTPUT LEVEL CONTROL - A Level Control for the 1 Watt
Output is provided (Reference 6)
ZONE 2 - 8 Ohm AMPLIFIER INPUT SOURCE SELECTION
The program source for the Input the 8 ohm Output can be select­ed from either AUX 1 - AUX 2 or the MODULE source. Set the Jumpers Set No. SW 701 to desired position. Default setting is AUX 1.
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
3
5
4
6
MOH - ZONE 1 INPUT SOURCE
DEFAULT JUMPER SETTING
2
MODULE
AUX 1
AUX 2
CAUTION: TO REDUCE THE RISK OF FIRE, REPLACE ONLY WITH SAME TYPE FUSE.
117V 500W MAX
UNSWITCHED
117V 60HZ
DMS3120 MOH 01
LINE FUSE
ZONE 1 LEVEL
MOH OUT
CAUTION: TO REDUCE THE RISK OF FIRE OR SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. DO NOT REMOVE COVER. THERE ARE NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
5A 250V
BALANCED
GROUND
ZONE 1
0 600
CLASS 2 WIRING ACCEPTABLE
ZONE 2
0 8
0 8
1 WA TT
1 WA TT
COM 8 25V 70V
SPEAKER OUTPUT
ZONE 2
LEVEL
PROFESSIONAL AUDIO & SOUND
DIGITAL MUSIC AMPLIFIER
POWER RATING SUPPLY V OL T AGE
POWER CONSUMPTION
VOX-1
SENS
SER. NO.
JUMPER
SW702
ZONE 2 INPUT SOURCE
DEFAULT JUMPER SETTING
MODULE
AUX 1
AUX 2
JUMPER
SW701
PAGE 25
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
INSTALLATION AND WIRING
MOH CONNECTIONS
Fig. 25 - Rear Panel MOH Connection Diagram
MOH/ZONE 1 AMPLIFIER SOURCE SELECTOR
MOH AMPLIFIER
An independent 600 ohm, 1 Volt Output, Transformer Balanced MUSIC-ON-HOLD Amplifier is provided. The Input SOURCE of the MOH Amplifier can be selected from either the AUX 1 - AUX 2 or MOD­ULE.
MOH - 600 OHM SYSTEM
Most Phone systems operate on a 600 ohm Input Impedance, if the Impedance required is 600 ohm connect the Amplifier to the Phone System MOH by using the diagram above (Reference 3).
MOH - 8 OHM, 1 WATT SYSTEM
Some older Key Phone systems require a 1 watt Power Output having an Output Impedance of 8 ohm to drive the Music on Hold feature. If the Impedance required is 8 ohm connect the Phone system MOH to the 8 ohm, 1 Watt MOH Output of the Amplifier (Reference 4).
CABLE
Use a cable consisting of a twisted pair of at least AWG 18.Use care in extending the cable and avoid routing near power lines, fluorescent lights and other systems that may generate a disturbing electric field.
SOURCE SELECTOR
Select the Input Source desired by following the instructions at right.
CAUTION: REMOVAL OF THE COVER PRESENTS AN ELECTRI­CAL SHOCK HAZARD !
MUSIC ON HOLD AMPLIFIER
MOH/ZONE 1 SOURCE SELECTOR
The Source for the MOH/ZONE 1 Amplifier can be selected from either the AUX 1 - AUX 2 or MODULE by setting the JUMPER SET No. SW702 provided for this purpose. Default Setting for this Jumper Set is AUX 1.To change the setting do the following:
ACCESS TO THE MOH/ZONE 1 INPUT SOURCE SETTING
1) Remove Power Cord from AC Outlet.
2) Remove the three screws on each side of the amplifier holding the amplifier cover.
3) Lift Cover and locate the Jumpers Set No SW702 on the MOH Amplifier Board (see Function Switches Jumpers Location Diagram).
4) Set Jumper as required (AUX 1 - AUX 2 or MODULE)
5) Replace protective cover.
LEVEL CONTROL
After the wiring is completed adjust the MOH/ZONE 1 Amplifier Level Control on the rear panel to the desired output level (Reference 2).
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
Telephone
MOH
Input
600
Ohm
Telephone System
KSU
CAUTION: TO REDUCE THE RISK OF FIRE, REPLACE ONLY WITH SAME TYPE FUSE.
117V 500W MAX
UNSWITCHED
117V 60HZ
3120 MOH Zone 1
600 ohm MOH System
AWG 18 TWISTED PAIR
2
ZONE 1
LEVEL
GROUND
LINE FUSE
5A 250V
MOH OTPUT LEVEL CONTROL
ZONE 1
0 600
MOH OUT
BALANCED
CLASS 2 WIRING ACCEPTABLE
3
ZONE 2 0 8
0 8
1 WA TT
1 WA TT
COM 8 25V 70V
SPEAKER OUTPUT
4
MOH - ZONE 1
INPUT SOURCE
ZONE 2
LEVEL
PROFESSIONAL AUDIO & SOUND
DIGITAL MUSIC AMPLIFIER
POWER RATING SUPPLY V OL T AGE
POWER CONSUMPTION
VOX-1 SENS
SER. NO.
DEFAULT JUMPER
SETTING
MODULE
AUX 1
AUX 2
JUMPER
SW702
PAGE 26
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
INSTALLATION AND WIRING
USING SPEAKERS FOR ZONE 1 - ZONE 2
Fig. 26 - Rear Panel Zone 1 and 2 Speaker Connection Diagram
ZONE 1 AND 2 OPERATION
The Amplifier is equipped with two independent 1 Watt, 8 ohm Outputs designated ZONE 1 (Reference 4) and ZONE 2 (Reference 5).The Outputs may be utilized to power up to 4 speakers in various combinations as described in the dia­grams on the next page. This feature will provide a SEC­OND and THIRD ZONE (in addition to the main output) with up to 1 Watt of output power and will amplify only the Source from either AUX 1 - AUX 2 or MODULE (see input source selection) and will not be affected by the Paging (from MIC or TEL), VOX or MUTING.
It can be used in any area (up to 1 Watt) where only a Program Source is desired uninterrupted by Paging.
CABLE
Use an AWG 18 jacketed, twisted pair cable.
ZONE 1 AND 2 OPERATION ZONE 1 AND 2 SETTINGS
INPUT SOURCE SELECTOR
Independent JUMPER SETS for ZONE 1 (SW702) and ZONE 2 (SW701) are available to select the Input Source for the two 1 Watt Amplifiers.
DUAL PROGRAM SOURCE CAPABILITY
If desired separate program Sources may be used for ZONE 1 and ZONE 2. EXAMPLE: Use the program source from AUX 1 for ZONE 2 and the program source from AUX 2 for ZONE 2.
Select the Input Source desired by following the instructions in the MOH Amplifier Source Selection section.
LEVEL CONTROL
After the wiring is completed adjust the ZONE 1 (
Reference
2) and ZONE 2 (
Reference
6) Level Controls on the rear
panel to the desired output level.
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
1/4W
8
OHM
8
OHM
1/4W
MOH - ZONE 1
INPUT SOURCE
DEFAULT JUMPER
SETTING
MODULE
AUX 1
AUX 2
JUMPER
SW702
1/4W
1/4W
3120 Zone 1&2
8
OHM
8
Up to Four 8 ohm Speakers may
OHM
CAUTION: TO REDUCE THE RISK OF FIRE, REPLACE ONLY WITH SAME TYPE FUSE.
117V 500W MAX
UNSWITCHED
117V 60HZ
be Connected
LINE FUSE
5A 250V
ZONE 1 OUTPUT LEVEL CONTROL
4 Speaker System Max. Power Output= 1/4W Each
AWG 18
TWISTED P AIR
ZONE 1
GROUND
4
0 600
MOH OUT
BALANCED
2
ZONE 1
LEVEL
ZONE 1
ZONE 2 0 8
0 8
1 WA TT
1 WA TT
COM 8 25V 70V
SPEAKER OUTPUT
CLASS 2 WIRING ACCEPTABLE
TWISTED P AIR
ZONE 2
Up to Four 8 ohm Speakers may
ZONE 2 OUTPUT LEVEL CONTROL
AWG 18
be Connected
5
ZONE 2
LEVEL
DIGITAL MUSIC AMPLIFIER
POWER RATING SUPPLY VOL T A GE POWER CONSUMPTION
VOX-1
SENS
SER. NO.
6
PROFESSIONAL AUDIO & SOUND
1/4W
8
OHM
8
OHM
1/4W
ZONE 2
INPUT SOURCE
DEFAULT JUMPER
SETTING
MODULE
AUX 1
JUMPER
SW701
AUX 2
OHM
OHM
1/4W
8
8
1/4W
PAGE 27
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
INSTALLATION AND WIRING
Fig 27 - Using one 8 ohm Speaker
Fig 27A - Using two 4 or 8 ohm Speakers
Fig 27B - Using four 8 ohm Speakers
USING A SINGLE 8 OHM SPEAKER WIRING
USING A SINGLE 8 OHM SPEAKER PER ZONE
A single 8 ohm Speaker may be used connected to the ZONE 1 and ZONE 2 1 W att Output.In this configuration up to 1 Watt of Power will be available on each Speaker.
Independent Level Controls are provided.
ZONE 1 - ZONE 2 CONNECTING SPEAKERS
USING TWO 4 OR 8 OHM SPEAKERS WIRING
USING TWO 4 OR 8 OHM SPEAKERS
The Figure at left shows: ZONE 1 with two 4 ohm speakers connected in series, each speaker provides ½ Watt power output (1 Watt Total).
ZONE 2 with two 8 ohm speakers connected in series, each speaker provides ¼ Watt power output (½ Watt Total).
Independent Level Controls are provided.
USING FOUR 8 OHM SPEAKERS WIRING
USING FOUR 8 OHM SPEAKERS PER ZONE
Four 8 ohm Speakers are used and connected to the 1 Watt Output. In this configuration up to 1/4 Watt of Power will be available on each Speaker (1 Watt Total).
Independent Level Controls are provided.
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
Max. Power Output
1 Watt
ZONE 1
LEVEL
3120 MOHspk01
4 ohm 4 ohm
½ W
When using two
4 Ohm Speakers
the maximum Output Power to each Speaker is
½ Watt
ZONE 1
LEVEL
Zone 1 Zone 2
8 Ohm
-
+
ZONE 1
0 600
MOH OUT
BALANCED
Zone 1 Zone 2
+
0 600
--
ZONE 1
0 8
1 WA TT
½ W
+
0 8
8 Ohm
-
ZONE 2 0 8
1 WA TT
¼ W ¼ W
ZONE 2 0 8
+
8 Ohm
-
+
When using two 8 Ohm
Speakers the maximum
Output Power to each
Speaker is ¼ Watt
ZONE 2
LEVEL
8 Ohm
-
ZONE 2
LEVEL
+
3120 Mohspk02
MOH OUT
BALANCED
1 WA TT
1 WA TT
Maximum Output
Power to each
Speaker is
¼ Watt
ZONE 1
LEVEL
3120 Mohspk03
Zone 1
8 ohm8 ohm
¼ W
+
¼ W ¼ W
+
0 600
MOH OUT
BALANCED
¼ W
--
8 ohm8 ohm
--
ZONE 1
0 8
1 WA TT
¼ W ¼ W
+
¼ W ¼ W
+
ZONE 2
0 8
1 WA TT
Zone 2
+
+
8 ohm8 ohm
+
--
8 ohm8 ohm
+
--
ZONE 2
LEVEL
PAGE 28
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
POWER SUPPLY
The Amplifier provides a 24 Volt - 250 mA DC Regulated Auxiliary Power Supply Output (Reference 8).
CABLE
To connect the Power Supply Output to accessories use a two conductor wire not less than AWG 18.This minimum wire gauge is necessary to minimize potential Voltage Drops in long wire connection applications.For wire resist­ance refer to Table below.
24 VOLT POWER SUPPLYREGULATED AUXILIARY POWER SUPPLY
Fig. 28 - 24 Volt Power Supply Output Diagram
WIRE GAUGE - RESISTANCE TABLE
WIRE RESISTANCE IN
AWG OHMS per 1000 Ft.
16 4.016 18 6.385 20 10.15 22 16.14 24 25.67 26 40.81
NOTE:
When calculating the Wire Resistance for each run using a two conductor Wire the wire Resistance should be doubled.
EXAMPLE: The Total Resistance of a 1000 Ft. run of a AWG 24 two conductor Wire is:
25.67 X 2= 51.34 Ohm
VOX RELAY
The Amplifier provides a VOX RELAY (Reference 7) with a single pole dual throw set of contacts. Figure A at left shows the contacts when the Relay is not activated.Figure B shows the contacts when the Relay is activated.
The Relay can be configured to activate when either VOX 1 (M1) or VOX 2 (M2) or both (VOX 1 and VOX 2) are acti­vated.
The VOX RELAY will remain engaged for as long as the VOX is active.
SWITCHSET SW206 - The SW206 is defaulted to M1. When VOX 1 is activated the Relay is switched ON. The factory setting can be changed to set the Relay to activate with either VOX 1 - VOX 2 or both.
Both Jumpers (M1 - M2) may be installed.
RELAY CONTACTS RATING
7 AMPERE AT 30 VDC MAXIMUM RATING.
VOX RELAY FUNCTIONSVOX RELAY
Fig. 28A - VOX Relay Output Terminals
INSTALLATION AND WIRING
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
8
TM
DIGITAL MUSIC SERIES
3120 Power Supply Output
VOX RELAY
NC C NO
24V DC
250 mA
+-
VOX NOT ACTIVATED
MUTE 1 BUSS ON
MUTE 2 BUSS OFF
SWITCHSET SW206 DEFAULT SETTING
M1
JUMPER
SW206
X
M2
VOX ACTIVATED
MUTE 1 BUSS ON
MUTE 2 BUSS OFF
M1
JUMPER
SW206
X
M2
Q237
D211
Q237
D211
7
MASTER REMOTE
MUTE 1
VOLUME
MUTE 2
GROUND
UNMUTE
MIC1 G M2
M1 RVC
RVC
C
VOX RELAY
+
RL201
VOX RELAY
+
RL201
COM
COM
A
NO
NC
B
NO
NC
VOX RELAY
NC C NO
24V DC 250 mA
+-
GROUND
UNMUTE
MIC1 G M2
MUTE 2
M1 RVC
MASTER REMOTE
MUTE 1
VOLUME
RVC
C
3120 Vox relay 01
PAGE 29
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
INSTALLING AND USING A BOSE® EQUALIZER MODULE
Fig. 26 - Method 1 Module Wiring Diagram
BOSE® is a Registered Trademark of BOSE Corporation
METHOD 1
EQUALIZING THE PROGRAM ONL Y
BY USING THIS METHOD THE MUSIC PROGRAM ONLY IS EQUAL­IZED BY THE MODULE.
BE SURE THAT THE TONE BYPASS SWITCH IS IN THE ON POSITION
1) Connect the Output of the PRO­GRAM SOURCE unit to the Module IN Jack.
2) Connect the EQ. OUT Jack of the Module to INPUT 4/AUX 1 of the Amplifier.
LEVEL CONTROLS - Adjust INPUT 4/AUX 1 Front Panel Control to 1 o'clock. Turn Rear Panel ATTENUA­TOR Control slowly cloc kwise until the desired Output Level is achieved After above adjustments are completed use the INPUT 4/AUX 1 Front Panel Control to increase or decrease the Music Level as desired.
CAUTION: PRIOR TO INSTALLING THE BOSE® MODULE IN THE AMPLIFIER FOLLOW THE INSTRUCTIONS SUPPLIED WITH THE MODULE AND THEN READ THE INSTRUCTIONS IN THIS MANUAL’S “INSTALLING A MODULE” SECTION
METHOD 2
USING THE EQ LINK
BY USING THIS METHOD ALL THE AMPLIFIER INPUTS ARE EQUAL­IZED BY THE MODULE.
BE SURE THAT THE TONE BYPASS SWITCH IS IN THE ON POSITION
1) Connect the Output of the PRO­GRAM SOURCE unit to the INPUT 4 (or INPUT 2) L and R Jacks.
2) Connect the EQ. OUT Jack of the Module to the POWER IN Jack of the Amplifier.
3) Connect the EQ. IN Jack of the Module to the PREAMP. OUT Jack of the Amplifier.
4) Set EQ LINK Switch on the Amplifier to IN.
LEVEL CONTROLS - Adjust INPUT 4/AUX 1 Front Panel Control to 1 o'clock. Turn Rear Panel ATTENUA­TOR Control slowly cloc kwise until the desired Output Level is achieved After above adjustments are completed use the INPUT 4/AUX 1 Front Panel Control to increase or decrease the Music Level as desired.
Fig. 26B - Method 2 Module Wiring Diagram
INSTALLATION AND WIRING
®
TM
DIGITAL MUSIC AMPLIFIERS
PROFESSIONAL AUDIO & SOUND
DIGITAL MUSIC SERIES
METHOD 1
Equalize
Music Only
WARNING: THIS APPLIANCE
MUST BE EARTHED
INPUT 2 (MIC)
BOSE MODULE METHOD 01
SET TONE BYPASS
Connect to INPUT 4/AUX 1
SWITCH TO ON
LISTED
COMMERCIAL
AUDIO
EQUIPMENT
30TJ
US
EQ LINK
IN OUT
EQ LINK
SUB OUT
PRE EQ
SUB OUT POST EQ
MIX
BUSS
LINE OUT
600
INPUT 4 REMOTE VOLUME
ON
TONE
BYPASS
AUX2 47Kohm 100 mV INPUT5 (MIC-AUX2)
MUSIC OUTPUT
SATELLITE RECEIVER
PRE
OUT
POWER
IN
INPUT 4 (MIC) INPUT 3 (MIC) G COM HOT RVC RVC G COM HOT G COM HOT G COM HOT
250ohm 1.5mV
BALANCED
INPUT-4(AUX1) 47kohm 100mV
(AUX1)
ATTENUATOR
OFF
CD PLAYER
TEL
G COM HOT
600 ohm 100mV
TRACK 01
INPUT-5(AUX2)
47kohm 100mV
L
ATTENUATOR
R
BY INTERNAL
TEL OUTPUT
(AUX2)
INPUT 5
MIC-AUX2
SWITCH
LEVEL
Connect to
Module
EQ OUT
EQ
AUDIO
OUT
L
R
IN
102 EQ. MODULE
Connect Music
Source Output
to Module EQ IN
PAGE 30
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE DMS3040/3080/3120
RESTAURANT/DINER WITH MUSIC AND JUKEBOX - APP. DATA 121
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
JUMPER
APPLICATION
This Note illustrates a typical installation in a Restaurant/Diner/Lounge using Background Music and a Jukebox. The Background Music can be automatically interrupted when the Jukebox is activated. The Background Music is then automatically restored once the Jukebox stops pla ying.This built-in feature of the DMS Amplifier eliminates the need of any external device.
PAGING MICROPHONE
PRIORITY PAGING MICROPHONE - A Low Impedance Dynamic Microphone can be connected to the Amplifier INPUT 1. The Microphone Input can be set to provide
Priority Paging
over both the Music Program and the Jukebox if activated. Optionally Paging may be generated from the Phone system if desired.
PAGING FROM THE PHONE SYSTEM
PRIORITY PAGING FROM THE PHONE SYSTEM - Paging may be generated from a Phone System by using the TEL INPUT of the Amplifier. The TEL INPUT can be set to provide
Priority Paging
over both the Music Program and the Juk ebo x if activ ated.The TEL INPUT provides a 600 ohm Transformer balanced Phone interface.
MUTE 2 DELAY
The Jukebox Configuration utilizes the VO X/MUTE 2 Buss .In order to prevent the premature JUKEBOX/MUSIC SOURCE switching (the Music Source cuts-in while the Jukebox is active) a MUTE 2 DELAY TRIMMER is available on the Rear panel to increase the MUTE 2 DELA Y as necessary. The MUTE 2 DELAY can be adjust­ed from 3 to 30 Seconds. EXAMPLE:If the Jukebox is playing and the Tune has a long pause or the long pause while the Jukebox is cycling between CD’s it is possible that the Music Source (Background Music) may cut-in causing annoying and unwanted
chatter
while the Jukebox is still active.T o pre v ent this prob lem the MUTE 2 TIME DELAY should be adjusted accordingly.
JUKEBOX REMOTE VOLUME CONTROL
A Jukebox Remote Volume Control may be provided to adjust the Output Level independently from the Background Music Source. The Jukebox Music Le vel should be set in accordance to the ambi­ent noise which may change during peak business hours.The AUX 1 Input (used for the Jukebox) is equipped with a Remote Volume Control Feature. Use the optional PASO Model RVC10W (10K) Volume Control mounted on a single gang plate.
MUSIC ON HOLD
The Zone 1 Amplifier provides a separate 600 ohm Transformer Balanced Music on Hold Output for the Telephone system. If the Zone 1 Input Selector Switch is set to Input 3, the MOH Output receives only the PROGRAM from the the MUSIC SOURCE with­out Paging or the Jukebox interruptions.
ZONE 1 & 2 ONE WATT - 8 OHM OUTPUT
The ZONE 1 and ZONE 2 Outputs may be used to cover small area with MUSIC ONLY without interruption from the Microphone or Phone Paging or the music from the Jukebox. The Program Source for both 1 Watt Amplifiers may be independently selected through Internal Jumpers (see Diagram).Output Level may be also independently adjusted by the separate Level Controls.
ZONE 1 AND 2 SPEAKERS
The Wiring Diagram shows the connection of up to 4 (8 ohm) Speakers for the Zone 1 & 2 - 1 Watt Amplifier.When 4 Speakers are used each Speaker Output will be a 1/4 Watt.
INPUT JUMPERS - SWITCHES SETTING
The Diagram indicates the various Input Settings for this applica­tion. Some settings may be already “Defaulted”when the Amplifier is shipped and do not need re-setting.
MUTE 1 ON
MUTE 2 ON
JUMPER
JUMPER
SW223
MUTE JUMPERS
M1
M2
OFF
VOX 2 OFF
VOX 1 OFF
JUMPER
SW213
VOX JUMPERS
V1
V2
OFF
INPUT 5 (AUX 2) SETTINGS
AUX 2 MIC 5
AUX 2 - MIC 5 SWITCH
MUTE 1 ON
JUMPER
MUTE JUMPERS
M1
OFF
VOX JUMPERS
V1
OFF
SW208 and SW229
SW217
M2
VOX 2 ON
JUMPER
SW212
V2
SATELLITE RECEIVER
JUKEBOX
AUTOMATICALLY
INPUT 4 (AUX 1) SETTINGS
SW228
AUX 1 MIC 4
AUX 1 - MIC 4 SWITCH
1/4W
8
OHM
1/4W
8
OHM
ZONE 2
ONLY ZONE
AUX 2 AUX 1 MOD
JUMPER
Up to Four 8 ohm
SW702
Telephone
OPTIONAL MUSIC
ZONE 1 MOH SETTING
KSU
RING
PASO RVC10W
SHIELD
VOX 2 ON
SW215
V2
MUTES THE
MUSIC SOURCE
WHEN SWITCHED
1/4W
8
OHM
1/4W
8
OHM
connected
ZONE 2 SOURCE SETTING
Speakers may be
NO JUKEBOX
MUSIC ON HOLD
RECEIVES MUSIC
ONLY - NO PAGING
R
L
MUSIC
SOURCE
L
R
JUKEBOX
ON
MUTE-2
DELAY
3 to 30 Sec
INPUT
MUTE 2 DELAY CONTROL
TIME OVER MUSIC SOURCE
ADJUSTS JUKEBOX MUTING
ADJUSTS OUTPUT
ZONE 2 LEVEL CONTROL
LEVEL
ZONE 2
AUX 2
JUMPER
AUX 1 MOD
600 ohm MOH System
600
Ohm
Input
MOH
KSU
(AUX2)
ATTENUATOR
L
47kohm 100mV
INPUT-5(AUX2)
INPUT-4(AUX1)
47kohm 100mV
(AUX1)
ATTENUATOR
MIX
BUSS
PRE EQ
SUB OUT
PRE
OUT
EQ LINK
30TJ
AUDIO
LISTED
EQUIPMENT
COMMERCIAL
CUS
RVC
MASTER
REMOTE
VOLUME MUTE 1
M1 RVC
MUTE 2
GROUND
UNMUTE
MIC1 G M2
SPEAKERS
LEVEL OF ZONE 2
24V DC
250 mA
+-
VOX RELAY
NC C NO
LEVEL
ZONE 2
SW701
0 8
ZONE 2
0 8
ZONE 1
0 600
AFIN DE REDUIRE LE RISQUE
LEVEL
ZONE 1
ATTENTION:
D'INCENDIE REMPLACER SEUL PAR UN
FUSIBLE DE MEME TYPE.
MUSIC ON HOLD OUTPUT
Telephone System
CAUTION: TO REDUCE THE
RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE
FUSE.
MODULE
STANDARD
PORT ACCEPTS
R
OFF
ON
IN OUT
CAUTION
DMS3120
CAUTION: REMOVE
POWER CORD FROM
AC OUTLET PRIOR TO
LEVEL
SWITCH
INPUT 5
MIC-AUX2
BY INTERNAL
TEL OUTPUT
TEL
G COM HOT
TONE
BYPASS
AUX2
47Kohm 100 mV
INPUT5 (MIC-AUX2)
600
INPUT 4
LINE OUT
VOLUME
REMOTE
SUB OUT
POST EQ
G COM HOT RVC RVC G COM HOT G COM HOT G COM HOT G COM HOT
INPUT 4 (MIC) INPUT 3 (MIC)
IN
POWER
EQ LINK
INPUT 2 (MIC)
DO NOT OPEN
RISK OF ELECTRIC SHOCK
MUST BE EARTHED
INPUT 1 (MIC)
WARNING: THIS APPLIANCE
850 VA
120 W RMS
117V 60 HZ
DELAY
SENS
VOX-2 MUTE-2
DIGITAL MUSIC AMPLIFIER
PROFESSIONAL AUDIO & SOUND
POWER RATING
SUPPLY VOL T A GE
POWER CONSUMPTION
SENS
VOX-1
1 WA TT
1 WA TT
ATTENTION: POUR REDUIRLES RISQUES D' INCENDIE
OU DE CHOC ELECTRIQUE, NE PAS EXPOSER A LA PLUIE
OU L' HUMIDITE, NE PAS ENLEVER LE COUVERCLE. AUCUN
REGLAGE A L' INTERIEUR. POUR REPARATION CONSULTER
UNE PERSONNE QUALIFIEE
COM 8 25V 70V
BALANCED
MOH OUT
GROUND
CAUTION: TO REDUCE THE RISK OF FIRE OR
SHOCK DO NOT EXPOSE THIS APPLIANCE TO
RAIN OR MOISTURE. DO NOT REMOVE COVER.
THERE ARE NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
UNSWITCHED
117V 500W MAX
INSTALLING MODULE
600 ohm 100mV
BALANCED
250ohm 1.5mV
SER. NO.
SPEAKER OUTPUT
DMS3120rear
5A 250V
LINE FUSE
117V 60HZ
TEL INPUT SETTINGS
Phone Paging
MUSIC
PHONE HAS
PRIORITY OVER
INPUT 4
REMOTE
VOLUME
PAGING MICROPHONE
AND JUKEBOX
MUSIC SOURCE
PRIORITY OVER
MICROPHONE HAS
DMS AP121
VOX 1 ON
VOX 2 ON
JUMPER
JUMPER
SW214
VOX JUMPERS
V1
V2
OFF
TIP
AND JUKEBOX
OPTIONAL
REMOTE
VOLUME
JUKEBOX
MIC
LO Z
Push to Talk Key
b50side
VOX 1 ON
JUMPER
JUMPER
VOX JUMPERS
V1
OFF
INPUT 1 (MIC 1) SETTINGS
25V/70V Speaker 25V/70V Speaker 25V/70V Speaker
DMS JUKEBOX APP 121
DIGITAL MUSIC SERIES
TM
AUTO SERVICE STATION C - STORE - APP. DATA 123
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
PAGE 31
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEDMS3040/3080/3120
APPLICATION
This Note illustrates a typical Auto Service Station C-Store application. The size of the Service Station and the number of Gas Pump Islands to cover will determine the amount of outdoor Waterproof Speakers required and the Power Output of the Amplifier.
GAS PUMP OUTDOOR SPEAKERS
40 WATT SYSTEM EXAMPLE - The PASO Model C55DMST Waterproof Music Speaker is recom­mended.Typically each Speak er should be tapped at 5 Watt. In this configuration up to 8 Speaker may be used with the Model DMS3040 40 Watt Amplifier for distribution of Music and Messages at the Gas Pumps.
For larger systems use a higher power Amplifier and the additional quantity of speakers required.
C _ STORE INDOOR SPEAKERS
The Amplifier is equipped with two independent 1 Watt , 8 ohm Amplifiers = ZONE 1 and ZONE 2. C-STORE - Up to 4+4 Ceiling Speakers may be utilized indoors in the Store area, Rest Rooms or other area such as a separate concession. By uti­lizing the separate (2) 1 Watt Amplifiers as a first and second zone, only the Music program will be distributed inside the Store. This avoids the con­tinuous and annoying repeating of the messages in the indoor areas. The output level may be adjusted by the 1st and 2nd Zone Level Control.
ZONE 1 - ZONE 2 PROGRAM SOURCE SELEC­TOR The program Source for each Zone Output may be selected by setting the Zone 1 and 2 Jumper Set to either AUX 1 - AUX 2 or Module Source.
MUSIC ON HOLD
The Zone 1 Amplifier provides a separate 600 ohm Transformer Balanced Music on Hold Output for the Telephone system. If the Zone 1 Input Select Jumper Set is set to AUX 1, the MOH Output receives the Music from the Satellite Receiver without Paging or Messages interrup­tions.
PAGING MICROPHONE
PRIORITY PAGING MICROPHONE - A Low Impedance Dynamic Microphone can be connect­ed to the Amplifier INPUT 1.The Microphone can be set to provide
Priority Paging
over both the Music Program and the Message Repeater. Optionally Paging may be generated from the Phone system if desired.The TEL INPUT provides a 600 ohm Transformer balanced Phone interface.
MESSAGE REPEATER
The Message Repeater provides pre-recorded Messages at the
Gas Pumps Only
. Each time a message is initiated by the Repeater (AUX 1) the Music (AUX 2) is automatically muted for the dur a­tion of the message.
REPEATER REMOTE VOLUME
A Master Remote Volume Control PASO Model RVC10W may be provided to adjust the Output Level of the Message Repeater in accordance to the outdoors noise.
MUTE 1 ON
MUTE 2 ON
JUMPER
JUMPER
SW223
MUTE JUMPERS
M1
M2
OFF
VOX 2 OFF
VOX 1 OFF
JUMPER
SW213
VOX JUMPERS
V1
V2
OFF
INPUT 5 (AUX 2) SETTINGS
AUX 2 MIC 5
AUX 2 - MIC 5 SWITCH
SW208 and SW229
MUTE 1 ON
JUMPER
SW217
MUTE JUMPERS
M1
M2
OFF
VOX 2 ON
MESSAGES MUTE
MUSIC AT THE PUMPS
JUMPER
SW212
VOX JUMPERS
V1
V2
OFF
INPUT 4 (AUX 1) SETTINGS
SW228
AUX 1 MIC 4
AUX 1 - MIC 4 SWITCH
1/4W
8
OHM
1/4W
8
individual requirement.
OHM
The use of both Outputs is optional follow the
ZONE 2
ONLY ZONE
Up to 4-8 ohm Speakers may be connected to each Output.
CEILING SPEAKERS MOUNTED INSIDE C-STORE
OPTIONAL MUSIC
The Amplifier provides two independent 1 Watt-8 Ohm Outputs.
AWG 18
TWISTED PAIR
8
8
OHM
OHM
1/4W
8
CEILING SPEAKERS MOUNTED INSIDE C-STORE RECEIVE MUSIC ONLY - NO MESSAGES OR PAGING
1/4W
ZONE 1
ONLY ZONE
OPTIONAL MUSIC
OHM
ZONE 1 MOH SETTING
AUX 2 AUX 1 MOD
1/4W
8
OHM
1/4W
JUMPER
SW702
MUSIC
SATELLITE RECEIVER
SOURCE
L
R
MESSAGE REPEATER
MUTE-2
ZONE 2
1/4W
8
OHM
1/4W
8
OHM
connected
ZONE 2 SOURCE SETTING
Speakers may be
Up to Four 8 ohm
LEVEL
ZONE 1
600 ohm MOH System
MUSIC ON HOLD
RECEIVES MUSIC
ONLY - NO PAGING
NO MESSAGE REPEATER
Telephone
MOH
VOX 1 ON
R
L
DELAY
3 to 30 Sec
RECEIVER
OVER SATELLITE
ADJUSTS MESSAGE
REPEATER MUTING TIME
MUTE 2 DELAY CONTROL
SPEAKERS
LEVEL OF ZONE 2
ADJUSTS OUTPUT
ZONE 2 LEVEL CONTROL
LEVEL
AUX 2
JUMPER
AUX 1 MOD
SW701
MUSIC ON HOLD OUTPUT
600
Ohm
Input
KSU
Telephone System
PORT ACCEPTS
(AUX2)
ATTENUATOR
L
R
47kohm 100mV
INPUT-5(AUX2)
INPUT-4(AUX1)
47kohm 100mV
(AUX1)
ATTENUATOR
OFF
ON
MIX
BUSS
PRE EQ
SUB OUT
PRE
OUT
EQ LINK
30TJ
AUDIO
LISTED
EQUIPMENT
COMMERCIAL
IN OUT
CUS
RVC
MASTER
REMOTE
VOLUME MUTE 1
M1 RVC
MIC1 G M2
+-
NC C NO
LEVEL
0 8
0 8
0 600
LEVEL
CAUTION
1 WA TT
1 WA TT
BALANCED
MOH OUT
MUTE 2
GROUND
UNMUTE
24V DC
250 mA
VOX RELAY
ZONE 2
ZONE 2
ZONE 1
AFIN DE REDUIRE LE RISQUE
ZONE 1
D'INCENDIE REMPLACER SEUL PAR UN
FUSIBLE DE MEME TYPE.
ATTENTION:
CAUTION: TO REDUCE THE
RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE
FUSE.
MODULE
STANDARD
CAUTION: REMOVE
INSTALLING MODULE
POWER CORD FROM
AC OUTLET PRIOR TO
LEVEL
SWITCH
INPUT 5
MIC-AUX2
BY INTERNAL
TEL OUTPUT
TEL
TONE
BYPASS
AUX2
47Kohm 100 mV
INPUT5 (MIC-AUX2)
600
INPUT 4
LINE OUT
VOLUME
REMOTE
SUB OUT
POST EQ
INPUT 4 (MIC) INPUT 3 (MIC)
IN
POWER
EQ LINK
INPUT 2 (MIC)
DO NOT OPEN
RISK OF ELECTRIC SHOCK
MUST BE EARTHED
INPUT 1 (MIC)
WARNING: THIS APPLIANCE
850 VA
120 W RMS
117V 60 HZ
DMS3120
DIGITAL MUSIC AMPLIFIER
PROFESSIONAL AUDIO & SOUND
POWER RATING
SUPPLY VOL T A GE
POWER CONSUMPTION
ATTENTION: POUR REDUIRLES RISQUES D' INCENDIE
OU DE CHOC ELECTRIQUE, NE PAS EXPOSER A LA PLUIE
OU L' HUMIDITE, NE PAS ENLEVER LE COUVERCLE. AUCUN
REGLAGE A L' INTERIEUR. POUR REPARATION CONSULTER
UNE PERSONNE QUALIFIEE
COM 8 25V 70V
CAUTION: TO REDUCE THE RISK OF FIRE OR
SHOCK DO NOT EXPOSE THIS APPLIANCE TO
RAIN OR MOISTURE. DO NOT REMOVE COVER.
THERE ARE NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
UNSWITCHED
117V 500W MAX
G COM HOT
G COM HOT RVC RVC G COM HOT G COM HOT G COM HOT G COM HOT
DELAY
SENS
VOX-2 MUTE-2
SENS
VOX-1
GROUND
600 ohm 100mV
BALANCED
250ohm 1.5mV
SER. NO.
SPEAKER OUTPUT
DMS3120rear
5A 250V
LINE FUSE
117V 60HZ
Phone Paging
INPUT 4
PAGING MICROPHONE
MICROPHONE HAS
VOX JUMPERS
OFF
TEL INPUT SETTINGS
MUSIC
REPEATER
PHONE HAS
AND MESSAGE
PRIORITY OVER
REMOTE
VOLUME
REPEATER
AND MESSAGE
PRIORITY OVER
SATELLITE RECEIVER
VOX 2 ON
JUMPER
JUMPER
SW214
V1
V2
KSU
TIP
RING
OPTIONAL
PASO RVC10W
REMOTE
VOLUME
MESSAGE
REPEATER
MIC
LO Z
Push to Talk Key
b50side
SHIELD
VOX 1 ON
JUMPER
VOX JUMPERS
V1
OFF
INPUT 1 (MIC 1) SETTINGS
25V/70V Speaker 25V/70V Speaker 25V/70V Speaker
GAS PUMP SPEAKERS - MUSIC/MESSAGES AND PAGING
DMS C-STORE APP 123
PASO
C55DMSTW - White
PASO MODEL B500X MICROPHONE
VOX 2 ON
JUMPER
SW215
V2
Waterproof Speaker
TM
DIGITAL MUSIC SERIES
CUSTOMER SERVICE
PAGE BACK
REPLACEMENT PARTS
Please provide complete information when you request replace­ment parts from either the Factory or a Paso Authorized Distributor. Be certain to include the Part Number and Description as it appears on the parts list, the Model Number of the unit and if possible the Serial Number and the date of pur­chase of the unit. Replacement parts inventory is maintained specifically to repair Paso products.Part sales for other reasons or applications will be declined.
ORDERING FROM THE FACTORY
Print all information on a purchase order form and mail to: PASO SOUND PRODUCTS, INC. 4750 Goer Drive - Building F CHARLESTON, SC 29406
Be sure to include the following:
- Paso part number
- Part description
- Quantity required
- Model number of the unit
- Serial number of the unit
- Your payment or your authorization for COD shipment for parts not covered by the Warranty or if your company has a current account with the factory
RETAIN ORIGINAL IN WARRANTY PARTS UNTIL YOU RECEIVE REPLACEMENTS. PARTS THAT SHOULD BE RETURNED TO THE FACTORY WILL BE LISTED ON YOUR PACKING SLIP.
For your convenience replacement parts are also available through Paso Authorized Distributors and Dealers nation wide. Obtain a location list directly from the Factory or your regional Paso Representative.
TECHNICAL CONSULTATION
- Need help with your installation ?
- Need help with the operation of the unit ?
- Need help with a repair ? Call or write for assistance. You will find our Technical Dept..
eager to help or assist you with any technical problem you may have encountered except “`Customizing'' for a unique applica­tion.
The effectiveness of our consultation service depends on the accuracy of the information you furnish. Be sure to tell us:
- The Model and Serial number of the unit
- The date of purchase
- An exact description of the difficulty
- All you have done in attempting to correct the problem Call our toll-free phone number:
1-800 231 3034
REPAIR SERVICE
REPAIR SERVICE
Repair service for out of warranty Paso products may be obtained form your local Paso distributor or any other qualified repair station.
In warranty repairs must be returned to the Factory. Prior authorization must be obtained from the Factory. Products received without authorization will be refused by our Receiving Dept..
IN WARRANTY REPAIR SERVICE
Call or write the Factory to obtain an authorization to return the product for repairs.
Pack the equipment in the original carton or in a strong carton with at least THREE INCHES of resilient packing material on all sides, top and bottom. Seal the carton with reinforced tape and mark it FRAGILE on at least two sides. Remember, the Carrier will not accept liability for shipping damages if the unit is improp­erly packed.
EQUIPMENT RECEIVED IN DAMAGED CONDITION DUE TO POOR PACKING WILL BE REFUSED AND THE WARRANTY COVERAGE IS AUTOMATICALLY VOIDED.
The Paso Sound Limited Warranty provides: The examination of the returned product must disclose in our
judgement, a manufacturing defect. The warranty does not extend to any product that has been subject to misuse, neglect, accident, improper installation or where the serial number of the product has been removed or defaced.
Ship via insured prepaid United Parcel Service or Parcel Post to:
PASO SOUND PRODUCTS, INC. 4750 Goer Drive - Building F CHARLESTON, SC 29406 Attn. SERVICE DEPARTMENT
The equipment will be returned freight prepaid after repairs. Be sure to include the following:
- Your name and address
- Date of purchase and copy of invoice
- A brief description of the difficulty
- A return address shipping label
-
OUT OF WARRANTY REPAIR SERVICE
Follow return instructions as per in warranty repair service.Prior to performing all necessary repairs, you will be advised of the charges and at that time a written authorization by you will be required including authorization to return the equipment COD for the service and shipping charges. This will avoid unnecessary delays in returning the equipment to you.
Printed in USA Manual OM 163
PROFESSIONAL AUDIO & SOUND
®
DIGITAL MUSIC AMPLIFIERS
TM
DIGITAL MUSIC SERIES
Loading...