Photosynthesis Tank
#3 Rubber
Stoppers (2)
Acrylic Dual Chamber
Photosynthesis Tank
Large #14 Rubber Stopper
with Sensor Ports
PS-2521A
Instruction Sheet
012-08997B
.
Included Items
Acrylic Dual Chamber Photosynthesis Tank
Large #14 Rubber Stopper with Sensor Ports
#3 Rubber Stoppers (2)
*See the PASCO catalog or the PASCO web site at www.pasco.com
for more information.
Required Items*
PASCO Interface
PASCO Data Acquisition Software
Dissolved Oxygen Sensor
Temperature Sensor
Recommended Items*
Magnetic Stirrer and Stir Bar
Teflon cover for Temperature Sensor
Introduction
The PS-2521A Photosynthesis Tank is designed for use with
either PASPORT or ScienceWorkshop sensors. Although the
basic Photosynthesis experiment can be accomplished with
test tubes, as described in the Dissolved Oxygen Sensor
Manual, the Photosynthesis Tank allows for greater flexibility when conducting this important experiment.
In a typical experiment your primary sample (such as elodea)
and water are placed in the inner chamber. the size and shape
of the inner chamber can accommodate a stirring bar and
other biological samples in addition to your primary sample.
The outer chamber is used to regulate temperature and/or
add chemicals that filter the incoming light, without directly
affecting the sample. the large rubber stopper is used to isolate the micro-environment of the inner chamber while
accommodating a Dissolved Oxygen Sensor and a Temperature Sensor. If one or both sensors are not in use, the
included #3 rubber stoppers can be used to seal the sensor
port. An unused port can also be used to introduce chemicals
to the primary sample during an experiment.
Warning
• Although the Photosynthesis Tank is specifically
designed for PASCO sensors, extra care should be taken
when inserting the Dissolved Oxygen Probe to prevent
any damage to the probe membrane.
Photosynthesis Tank Technical Support
Metal band of
the Dissolved
Oxygen Probe
must be submerged in the
sample
Dissolved
Oxygen
Probe
Temperature
Sensor
Limited Warranty For a description of the product warranty, see the
PASCO catalog. Copyright The PASCO scientific Instruction Sheet
is copyrighted with all rights reserved. Permission is granted to
non-profit educational institutions for reproduction of any part of this
manual, providing the reproductions are used only in their laboratories and classrooms, and are not sold for profit. Reproduction under
any other circumstances, without the written consent of PASCO scientific, is prohibited. Trademarks PASCO, PASCO Capstone,
PASPORT, SPARK Science Learning System, SPARK SLS, and
SPARKvue are trademarks or registered trademarks of PASCO scientific, in the United States and/or in other countries. For more information visit www.pasco.com/legal.
NOTE
For best results, fill the inner chamber of the Photosynthesis
Tank approximately two-thirds full with the primary sample.
Safety
Read the instructions before using this product. Students
should be supervised by their instructors. When using this
product, follow the instructions in this instruction sheet and
all local safety guidelines that apply to you.
More Information
For the latest information about the Photosynthesis Tank,
visit the PASCO web site at www.pasco.com and enter
“PS-2521A” in the Search window.
Technical Support
For assistance with any PASCO product, contact PASCO at:
Address: PASCO scientific
10101 Foothills Blvd.
Roseville, CA 95747-7100
Phone: +1 916-786-3800 (worldwide)
800-772-8700 (U.S.)
E-mail: support@pasco.com
Web www.pasco.com
2