Instruction Sheet
Broad Spectrum Light Sensor
PS-2150
Introduction
The Broad Spectrum Light Sensor is designed for use with the
PASCO OS-8539 Educational Spectrophotometer System and
OS-8544 Prism Spectrophotometer Kit. The Broad Spectrum
Light Sensor has a spectral response ranging from near infrared
through visible light.
Assembly
012-10078A
Included Equipment Part Number
Broad Spectrum Light Sensor PS-2150
Sensor Handle (1 included) CI-9874 (4-pack)
PASPORT Sensor Extension
Cable (not pictured)
Additional Equipment Required
PASPORT interface or datalogger See PASCO catalog
Educational Spectrophotometer
System
Prism Spectrophotometer Kit OS-8544
Other equipment required for use
with OS-8544 kit
PS-2500
or www.pasco.com
OS-8539
See PASCO catalog
or www.pasco.com
Quick Start
1. Follow the instruction provided with the OS-8544 kit to
assemble the spectrophotometer.
2. Use the metal handle (included with the spectrophotometer)
to attach the Broad Spectrum Light Sensor to the arm of the
spectrophotometer.
Note: Use the metal handle included with the spectrophotometer (not the
plastic handle included with the sensor) in order to electrically ground the
sensor.
3. Connect the PASPORT extension cable (included) to the sensor.
4. Connect the other end of the PASPORT extension cable to
your PASPORT interface.
Zeroing the Sensor
Press the TARE button on the sensor to set the present reading to
zero. During this step, the sensor must connected to a powered-on interface, but it is not necessary to be recording data.
1. Connect the Broad Spectrum Light Sensor to your
PASPORT interface.
2. If you are using a computer, connect the interface to it and
start DataStudio.
3. Press or click the start button to begin recording data.
®
Using the Sensor with the
Prism Spectrophotometer
Follow the instructions provided with the OS-8544 kit to acquire
data with the spectrophotometer.
Tip: Product instruction manuals are available at www.pasco.com.
Broad Spectrum Light Sensor PS-2150
Specifications
Sensing Element BaF
Spectral Response 300 nm to 10 000 nm
Maximum Sampling Rate 100 Hz
window, xenon gas-filled
2
thermopile
Technical Support
For assistance with any PASCO product, contact PASCO at:
Address: PASCO scientific
10101 Foothills Blvd.
Roseville, CA 95747-7100
Phone: 916-786-3800 (worldwide)
800-772-8700 (U.S.)
Fax: (916) 786-7565
Web: www.pasco.com
Email: support@pasco.com
Limited Warranty For a description of the product warranty, see the
PASCO catalog.
Copyright The PASCO scientific 012-10078A
Sensor Instruction Sheet
sion is granted to non-profit educational institutions for reproduction of any
part of this manual, providing the reproductions are used only in their laboratories and classrooms, and are not sold for profit. Reproduction under
any other circumstances, without the written consent of PASCO scientific,
is prohibited.
Trademarks PASCO, PASCO scientific, DataStudio, and PASPORT are
trademarks or registered trademarks of PASCO scientific, in the United
States and/or in other countries. All other brands, products, or service
names are or may be trademarks or service marks of, and are used to
identify, products or services of, their respective owners. For more information visit www.pasco.com/legal.
is copyrighted with all rights reserved. Permis-
Broad S pectrum Light
2
®