PASCO PS-2146 User Manual

®
Instruction Sheet
Temperature
port
Tubing
Pressure
port
Syringe
In-line
connector
Quick release
connector
Sensor
Fast Response
Temperature Probe
9 pin mini DIN
plug
Mini
stereo
plug
PASPORT Sensor
Extension Cable
012-08708B
*012-08708*
Absolute Pressure/Temperature Sensor
PS-2146
Included Equipment Part Number
Polyurethane tubing, 0.125” ID (2 ft.) In-line connector (4)
Quick release connector (4) Syringe, 60 cubic centimeters 699-166 Fast Response Temperature Probe PS-2135 (pack of three) PASPORT Sensor Extension Cable PS-2500 Required Equipment Part Number PASCO Interface and Software see the PASCO catalog or www.pasco.com Recommended Equipment Part Number Ideal Gas Law Syringe TD-8596A Absolute Zero Apparatus TD-8595
®
Absol ute Press ure/Temp erature Sensor PS-2146
Sensor
Pressure
port
Quick release
connector
Tubing
Syringe
Ideal Gas
Law Syringe
Sensor
Mini
stereo
jack
Quick
release
connector

Introduction

The Absolute Pressure/Temperature Sensor simultaneously measures gas pressure and temperature. The pressure range is from 0 kilopascals (kPa) to 700 kPa. The included Fast Response Temperature Probe plugs into the temperature port and has a range from -10 °C to 70 °C. The sensor includes tubing, quick release connectors, and in-line connectors.

Quick Start

1. Connect the sensor to your PASCO interface. If you are using a computer, connect the interface to it.
2. Plug the Fast Response Temperature Probe into the temperature port.
3. Start the PASCO data acquisition software.
4. Press, click, or tap the start button to begin recording data.
The display should show the atmospheric pressure and the ambient temperature.

Connecting the Syringe or a Stopper

1. Cut a piece of tubing to the desired length.
2. Insert a quick release connector into one end of the tubing.
3. Connect the tubing to the sensor by inserting the quick release con-
nector into the pressure port and twisting clockwise about one-eighth of a turn until the connector clicks into place.
4. Connect the other end of the tubing to the syringe.
NOTE: To connect a stopper instead of the syringe, put the small diameter end of the in-line connector into the tubing, and push the other end of the in-line connector into the hole in the stopper.
Important: Do not immerse the sensor in liquid or allow it to get wet.

Connecting the Sensor to the TD-8596A Ideal Gas Law Syringe

Plug the mini stereo jack of the Ideal Gas Law Syringe into the temperature port on the sensor.
Connect the quick release connector of the Ideal Gas Law Syringe into the pressure port on the sensor.
2 012-08708B