Instruction Sheet
Objects are not to scale.
Fast Response Temperature Probe
Stainless Steel Temperature Probe
Sensor
PASPORT
Input Port
Interface
Quad Temperature Sensor
PS-2143
012-08656D
.
Included Items
Quad Temperature Sensor
Stainless Steel Temperature Probe (2)
Fast Response Temperature Probe (3)
Polyurethane Tubing (0.3 m)
Adhesive Cover Disks (1 sheet)
Required Items*
PASCO Interface
PASCO Data Acquisition Software
*See the PASCO catalog or the PASCO web site at www.pasco.com for more information.
Recommended Items*
Sensor Extension Cable (PS-2500)
(PS-2153), three Fast Response Temperature Probes (PS-2135), a piece of polyurethane tubing, and a sheet of adhesive disk covers. The tubing can be used when a Stain­less Steel Temperature Probe is inserted into a stopper, and the adhesive disk covers can be used to hold the end of a Fast Response Temperature Probe in place.
The sensor is designed to work with a PASPORT-compatible interface and PASCO data acquisition software (such as PASCO Capstone) to measure temperature.

Setup the Sensor

Plug the sensor into one of the PASPORT input ports of a PASCO PASPORT-compatible interface.
Te fl o n

Introduction

®
Sensor Covers (CI-6549)
NOTE: If more distance is needed between the sensor and the interface, plug the sensor into a Sensor Extension Cable, and then plug the cable into the interface.
Plug one or more temperature probes into the sensor.
Start the PASCO data acquisition software.
Quad Temperature Sensor Specifications

Using PASCO Capstone Software

Click the “Hardware Setup” icon in the Tools palette to open the “Hardware Setup” panel. Confirm that the sen­sor’s icon appears with the interface’s icon.
Click one of the display templates in the Capstone work­book page, or double-click an icon in the “Displays” palette to open a data display.
By default, temperature from all the connected probes will be shown in a data display. Click “Data Summary” in the Tools palette to change what is displayed.

Using SPARKvue Software

Connect the sensor to a SPARKvue-compatible inter­face and start the software. The sensor parameter screen opens and shows the list of measurements for the sensor.
In the sensor parameter screen, touch the measurement, and then touch ‘Show’ to open a graph display.

More Information

For more information about collecting, recording, displaying and analyzing data, refer to the User’s Guide or Online Help System for the data acquisition software.

Sensor Usage

Caution: To avoid damaging the sensor box, do not put the Quad Temperature Sensor in water, liquids, chemicals, ovens, or fire at any time.
Tip: If the Quad Temperature Sensor is used to take freezer measurements, put the probe(s) in the freezer but deep the sensor box outside of the freezer.
Tip: The Stainless Steel Temperature Probe is slightly smaller than the holes in some rubber stoppers. In order to create a better fit, use a piece of the polyurethane tubing included with the sensor.
Tip: The tip of a Fast Response Tem­perature Probe can be held in place using one of the adhesive disk covers included with the sensor. Remove one of the disks from the sheet and remove the protecting paper to reveal the adhesive. Place the tip of the probe in the center of the disk. Place the disk on the item being measured.

More Information

Specifications

Quad Temperature Sensor Value
Range: -35°C to 135°C
Accuracy: ±0.5°C
Resolution: 0.0025°C
Repeatability 0.01°C
Stainless Steel Temperature Probe Value
Range: -35°C to 135°
Fast Response Temperature Probe Value
Range: -10°C to 70°C

Technical Support

For assistance with any PASCO product, contact PASCO at:
Address: PASCO scientific
10101 Foothills Blvd. Roseville, CA 95747-7100
Phone: +1 916-786-3800 (worldwide)
800-772-8700 (U.S.)
E-mail: support@pasco.com
Web www.pasco.com
Limited Warranty For a description of the product warranty, see the PASCO catalog. Copyright The PASCO scientific Instruction Sheet is copyrighted with all rights reserved. Permission is granted to non-profit educational institutions for reproduction of any part of this manual, providing the reproductions are used only in their laborato­ries and classrooms, and are not sold for profit. Reproduction under any other circumstances, without the written consent of PASCO sci­entific, is prohibited. Trademarks PASCO, PASCO Capstone, PASPORT, SPARK Science Learning System, SPARK SLS, and SPARKvue are trademarks or registered trademarks of PASCO sci­entific, in the United States and/or in other countries. For more infor­mation visit www.pasco.com/legal.

Product End of Life Disposal Instructions:

This electronic product is subject to disposal and recycling regula­tions that vary by country and region. It is your responsibility to recy­cle your electronic equipment per your local environmental laws and regulations to ensure that it will be recycled in a manner that protects human health and the environment. To find out where you can drop off your waste equipment for recycling, please contact your local waste recycle/disposal service, or the place where you purchased the product.
The European Union WEEE (Waste Electronic and Electrical Equipment) symbol (to the right) and on the product or its packaging indicates that this product must not be disposed of in a standard waste container.
For the latest information about the sensor, visit www.pasco.com and enter “PS-2143” or the product name in the Search window.
2
Loading...