PASCO PS-2135 User Manual

Instruction Sheet for the PASCO Models PS-2135
Fast Response Temperature Probe
stereo plug
012-08475E
probe tip
flexible wire
Introduction
The Fast Response Temperature Probe (PS-2135) measures temperature in degrees Celsius (-30 °C to +105 °C) and plugs into any PASPORT™ Temperature Sensor, or ScienceWorkshop® Thermistor Sensor. The Fast Response Temperature probe has applications for studying temperature gradients, evaporative cooling, outdoor air temperature, and environmental studies.
The probe can be placed on the surface of an object, on skin, in water, or even in mild chemical solutions. It has a 1-meter flexible wire, making it convenient for taking measurements in long flasks, between objects, or below the surface of a liquid. The adhesive mylar foam covers are designed to hold the probe tip and adhere it to a participant’s skin or to other flat surfaces. The mylar reduces environmental influences.
water temperature
sample data
probe in air
Inserted probe in water.
(53°C)
Adhesive Mylar Covers 10 Pack (PS-2525)
Additional Equipment Required
PASPORT Temperature Sensor (PS-2125),
ScienceWorkshop Thermistor Sensor (CI-6527A)
PASPORT interface and DataStudio (version 1.7
or later)
OR
ScienceWorkshop interface and DataStudio (version 1.8.5 or later)
Available Replacement Equipment
Fast Response Temperature Probe 012-08475E
Specifications
Range: -30 to +105 °C
Accuracy: ±0.5 °C
Resolution: 0.01 °C or better
Setup Procedure
1. Insert the stereo plug on the Fast Response Temperature Probe into the port on a PASPORT Temperature Sensor box or a ScienceWorkshop Thermistor Sensor.
2. Connect the Temperature Sensor to either a PASPORT interface or a ScienceWorkshop interface.
3. To collect data, place the probe in the liquid or object to be measured. Open DataStudio, and click the Start button. Follow the procedure to set up a trial and start collecting.
Using the Adhesive Mylar Cover
sensing tip in the center of the disk adhesive.
4. Place the adhesive mylar foam disk on a smooth (preferably hairless) skin surface
1. Remove one of the adhesive mylar foam cover disks from the sheet set.
2. Carefully remove the protective backing paper.
Procedure Notes:
Calibration of the PS-2125 Temperature Sensor
and Thermistor Sensor are generally not required. However, if you wish to calibrate the PS-2125, follow the instructions on the card supplied with your sensor or in the DataStudio online help. If necessary, download the instructions from PASCO’s website (www.pasco.com).
If using the probe with the Thermistor Sensor, set
up your experiment in DataStudio before collecting data. (i.e. In the Setup window, click on the Thermistor Sensor icon and drag it to an analog channel on the picture of the interface.)
Safety Precaution
To prevent damage to the probe, do not use the
probe in an open flame, on a hot plate, or beyond the recommended temperature range.
3. Place the Fast Response Temperature Probe
2