Instruction Sheet
Typ e -K Po r t
Type-K Temperature
Probe
Sensor
PASPORT
Input Port
Interface
Type-K Temperature Sensor
PS-2134
012-08453C
.
Included Items
Type-K Temperature Sensor
Type-K Thermocouple Probe (PS-2155)
Required Items*
PASCO Interface
PASCO Data Acquisition Software
*See the PASCO catalog or the PASCO web site at www.pasco.com
for more information.
Recommended Items*
Sensor Extension Cable (PS-2500)
®
Te fl o n
Sensor Covers (CI-6549)
Introduction
The PS-2134 Type-K Temperature Sensor measures temperature from a “Type-K” thermocouple probe. The tip of the
probe has a temperature rang of -200°C to 1000°C. The insulation on the probe can withstand temperatures between
-73°C and 482°C.
The sensor is designed to work with a PASPORT-compatible
interface (such as the PASCO 850 Universal Interface) and
PASCO data acquisition software (such as PASCO Capstone) to measure temperature.
Setup the Sensor
• Plug the sensor into one of the PASPORT input ports of
a PASCO PASPORT-compatible interface.
NOTE: If more distance is needed between the sensor and
the interface, plug the sensor into a Sensor Extension Cable,
and then plug the cable into the interface.
• Plug the “Type-K” thermocouple probe into the sensor.
• Start the PASCO data acquisition software.
Using PASCO Capstone Software
• Click the “Hardware Setup” icon in the Tools palette to
open the “Hardware Setup” panel. Confirm that the sensor’s icon appears with the interface’s icon.
• Click one of the display templates in the Capstone workbook page, or double-click an icon in the “Displays”
palette to open a data display.

Type-K Temperature Sensor Specifications
• By default, temperature will be shown in a data display.
Click “Data Summary” in the Tools palette to change
what is displayed if needed.
Using SPARKvue Software
• Connect the sensor to a SPARKvue-compatible interface and start the software. The sensor parameter screen
opens and shows the list of measurements for the sensor.
• In the sensor parameter screen, touch the measurement,
and then touch ‘Show’ to open a graph display.
More Information
For more information about collecting, recording, displaying
and analyzing data, refer to the User’s Guide or Online Help
System for the data acquisition software.
Sensor Usage
Caution: To avoid damaging the sensor box, do not put the
Type-K Temperature Sensor box in water, liquids, chemicals,
ovens, or fire at any time.
Tip: If the Type-K Temperature Sensor is used to take measurements of a
flame, do not let the flame make contact with the thermocouple’s insulation. Put only the tip of the
thermocouple probe into the flame.
Tip: If the Type-K Temperature Sensor is used to take freezer measurements, put the probe in the freezer but
deep the sensor box outside of the freezer.
SAFETY WARNING: When working with candles, flames,
or hot objects, always follow standard fire and health safety
procedures. Do NOT touch the Type-K probe tip. When the
probe is in a candle flame, it will be hot (between 400 and
1400°C).
Suggestion
Use the Type-K Temperature Sensor to map the temperatures
of a candle flame. Place the probe tip at different positions in
the flame.
Specifications
Type-K Temperature Sensor Value
Probe Tip Range: -200°C to 1000°C
Probe Insulation Range: -73°C to 482°C
Accuracy: ±3°C or 3% of reading
Resolution: 0.1°C
Sensing Element (tip): Chromel and alumel
thermocouple
More Information
For the latest information about the sensor, visit
www.pasco.com and enter “PS-2134” or the product name in
the Search window.
Technical Support
For assistance with any PASCO product, contact PASCO at:
Address: PASCO scientific
10101 Foothills Blvd.
Roseville, CA 95747-7100
Phone: +1 916-786-3800 (worldwide)
800-772-8700 (U.S.)
E-mail: support@pasco.com
Web www.pasco.com
Limited Warranty For a description of the product warranty, see the
PASCO catalog. Copyright The PASCO scientific Instruction Sheet
is copyrighted with all rights reserved. Permission is granted to
non-profit educational institutions for reproduction of any part of this
manual, providing the reproductions are used only in their laboratories and classrooms, and are not sold for profit. Reproduction under
any other circumstances, without the written consent of PASCO scientific, is prohibited. Trademarks PASCO, PASCO Capstone,
PASPORT, SPARK Science Learning System, SPARK SLS, and
SPARKvue are trademarks or registered trademarks of PASCO scientific, in the United States and/or in other countries. For more information visit www.pasco.com/legal.
Product End of Life Disposal Instructions:
This electronic product is subject to disposal and recycling regulations that vary by country and region. It is your responsibility to recycle your electronic equipment per your local environmental laws and
regulations to ensure that it will be recycled in a manner that protects
human health and the environment. To find out where you can drop
off your waste equipment for recycling, please contact your local
waste recycle/disposal service, or the place where you purchased
the product.