PASCO OS-8534A User Manual

®
Instruction Sheet
012-10299A
Aper ture Bracket
OS-8534A
1
2
3
4
Included Part s
1. Bracket with aperture disk and removable screen
3. Thumbscrew for attaching light sensor
4. Post
Additional Part Re qu ired
PA SPORT or
ScienceWorkshop
light , U V, IR, or
broad-spectrum sensor.
Introduction
The Aperture Bra cket a cts as a mask a nd ho lder for a l ight sen sor. By rotating a disk, you can select various apertures to control the sensor’ s spacial resolut ion and the amount of light entering the sensor . A remov able sc reen di splays light cas t to t he left and ri ght of apert ure . The Aper tu re Bra cke t also al low s a lig h t sens or to be mounted on the include d holder, so that th e sensor c an be us ed on a PASCO Basic Optics bench.
10% Screen
The small holes in the screen allow approxima tely 10% of inci­dent light thr ough to the sensor.
Circular Aperture
This aperture is approximately 8 mm in diameter. It allows th e maximum amount of light through to the sensor.
Translucent Screen
The translucent screen allows the sensor to measure illuminance, for instance when demonstrating the inverse-s quare law. The screen is approximately 8 mm in diameter.
0.1 mm
0.2 mm
2
N
E
S
T
H
G
I
L
4
0.3 mm
3
0.5 mm
P
E
10%
R
1.5 mm
1
®
A
4
3
R
5
8
-
S
O
A
T
U
R
E
B
R
6
O
S
R
O
F
T
A
E
C
K
5
1.0 mm
Assembly
1. Use the th u m b screw to fa st en th e s en so r to th e bracket as
illustrated.
About the Apertures
Slit Apertures
The six slit a perture s are ty pical ly used when scannin g the sensor across a spectrum or a diffraction pattern. Select a w i der slit to allow more light into the sensor or a narrower s lit to improve the spacial resolution. The approximate widths of the apertures are
0.1 mm, 0.2 mm, 0.3 mm, 0.5 mm, 1.0 mm, and 1.5 mm.
800-772-8700 www.pasco.com
Aperture Bracket OS-8534A
2. Turn the disk to select the desired aperture. The aperture in
use is in th e lowest po s i ti on.
3. (Optional) Attach the bracket to the included component
holder as il lustrat ed .
Attaching t he Bracket to a Rotary Motion Sensor
Using the Bracket with a Cuvette
To hold a cuvette (such as PASCO part SE-8739) in front of the sensor , fasten the sensor to the Ape r ture Bracket as ill ustrated, and place the cuvett e between the sensor and th e dis k.
Screw Storage
When the thumbscrew is not in use, screw it into the storage loca­tion as illustrated.
1. Screw the inc luded post into the br acket as illu strated.
2. Secure the post in the clamp of a Rotary Motion Sensor.
Removing the S creen
Loosen th e two thumbscrew s on the screen to rem ove it. The c ap­tured thumbscre w s rema in loosely connected to the detached screen.
Technical Support
For assistance with any PASCO product, contact PASCO at:
Address: PASCO scientific
10101 Foothills Blvd. Roseville , CA 95747-7100
Phone: 916 -786-3800 (worldwide)
800-772-8700 (U.S.) Fax: (916) 786-7565 Web: www.pasco.com Email: support@pasco.com
Limited Warranty For a description of the product warranty, see the PASCO catalog. Copyright The PASCO scientific 012-10299A
tion Sheet
non-profit educational institutions for reproduction of any part of this man­ual, providing the re productions are used only in their labo ratori es and classrooms, and are not sold for profit. Repro duction under any other cir­cumstances, without the written consent of P ASCO scientific, is prohibited. Trademarks PASCO, PASCO scientific, ScienceWorkshop, and P ASPORT are trademarks or registered trademarks of PASCO scientific, in the United States and/or in other countries. All other brands, products , or service names are or may be trademarks or servi c e marks of, and are used to identify, products or services of, their respective owners. For more information visit www.pasco.com/legal.