PASCO CI-6552A User Manual

Instruction Sheet for the PASCO Model CI-6552A
POWER AMPLIFIER II
CAUTION!
CI-6552A
POWER AMPLIFIER II
012-05783A
2/95
$1.00
Introduction
The PASCO CI-6552A Power Amplifier II is an acces­sory to the PASCO Signal Interfaces, Series 6500 and Mac65. It amplifies the output of the computer, allowing it to be used as a controlled DC power source or an AC function generator.
With the Power Amplifier II plugged into one of the ana­log channels of the Signal Interface, the appropriate soft­ware (Power Amplifier for DOS, Power Amplifier for APPLE II, or Science Workshop) can be used to generate the following types of waves (up to ±10V peak at 1A, up to 5,000 Hz):
• sine,
• square,
CI-6552A
POWER AMPLIFIER II
ON
CAUTION!
WHEN LIGHT IS ON
WAVEFORM IS DISTORTED.
DECREASE AMPLITUDE!
SIGNAL OUTPUT
0 to ±10 V 1 A MAX
Filter Select Switch
The CI-6552A Power Amplifier II has a filter select switch which is preset for use with the CI-6560 Signal Interface II (Mac65). The bandwidth at that switch posi­tion is about 100KHz, limited by the power amplifier’s feedback compensation section and the load. When using the Power Amplifier II with the CI-6510 Signal Interface (Series 6500), the bandwidth needs to be limited to
1.5KHz. To change the switch position push the filter se­lect switch in the back panel slot to the left, as shown in the illustration below.
Switch position
for CI-6510
Signal Interface
Switch position
for CI-6560
Signal Interface II
• triangle, and
• sawtooth.
This means the computer can now be used as an AC sig­nal generator to power external circuits while it monitors its own output current as well as other inputs. The Science Workshop software can also generate a DC output.
Phone (916) 786-3800 • FAX (916) 786-8905 • email: techsupp@PASCO.com
© 1995 PASCO scientific This instruction edited by Robert Morrison
better
ways to
teach physics
Power Amplifier II 012-05783A
Using Power Amplifier II
To install the Power Amplifier II, plug in its power cord and plug the DIN plug into Channel A, B, or C of the ap­propriate PASCO Signal Interface box (CI-6510 or CI-6560).
NOTE: Using Power Amplifier II with Series 6500, the Power Amplifier program is calibrated for channel C. The Power Amplifier II can also be plugged into Channel A or B but these channels are not automatically calibrated to read the current as is Channel C.
To use the output of the Power Amplifier II, connect the load to the banana jacks on the front of the Power Ampli­fier II. There is a power switch on the back left hand cor­ner of the Power Amplifier II.
WARNING! Do not turn on the power switch
until a program (either Power Amplifier, Data Monitor or Science Workshop) has been run and the desired output voltage has been selected.
When the computer is in DOS, the Power Amplifier will output 10 Volts if the power switch is on and this could overload a circuit that might be con­nected to it. The software controls this voltage: The Data Monitor Program sets the default voltage to zero and the Power Amplifier Program sets the default AC peak voltage to 5 Volts.
Equipment must be properly packed to prevent damage and shipped postage or freight prepaid. (Damage caused by improper packing of the equipment for return ship­ment will not be covered by the warranty.) Shipping costs for returning the equipment, after repair, will be paid by PASCO scientific.
Equipment Return
Should this product have to be returned to PASCO scien­tific, for whatever reason, notify PASCO scientific by let­ter or telephone BEFORE returning the product. Upon notification, the return authorization and shipping instruc­tions will be promptly issued.
NOTE: NO EQUIPMENT WILL BE AC-
CEPTED FOR RETURN WITHOUT AN AU­THORIZATION.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER ON UNIT. NO USER SERVICE­ABLE PARTS INSIDE. REFER SERVICING TO QUALI­FIED SERVICE PERSONNEL.
When the Power Amplifier II is operating, a green power indicator light on the front panel of the Power Amplifier II will be lit. There is also a red current overload light which comes on whenever the maximum current of 1 A is exceeded. If this warning light is on, the waveform is dis­torted and you should reduce the output voltage.
Limited Warranty
PASCO scientific warrants this product to be free from defects in materials and workmanship for a period of one year from the date of shipment to the customer. PASCO will repair or replace, at its option, any part of the product which is deemed to be defective in material or workman­ship. This warranty does not cover damage to the product caused by abuse or improper use. Determination of whether a product failure is the result of a manufacturing defect or improper use by the customer shall be made solely by PASCO scientific. Responsibility for the return of equipment for warranty repair belongs to the customer.
The lightning flash with arrowhead, within an equilateral triangle, is intended to alert the user of the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magni­tude to constitute a risk of electric shock to persons.
The exclamation point within an equi­lateral triangle is intended to alert the user of the presence of important oper­ating and maintenance (servicing) in­structions in the literature accompany­ing the appliance.