Partilink P2K-HL3E1, P2K-HL3E1-P, P2K-HRSL3E1, P2K-HRSL3E1-P, P2K-LHRS1E3-P User Manual

...
P2K-HRSL3E1/ P2K-LHRS1E3
User manual
P2K-HL3E1 1080p HDMI Extender over IP P2K-HL3E1-P 1080p HDMI Extender over IP with PoE
P2K-HRSL3E1 / P2K-LHRS1E3
P2K-HRSL3E1-P / P2K-LHRS1E3-P
1. Introduction 2
2. Features & Application 3
3. Specifications 4
4. Hardware Description 4
5. Installation 9
5.1 Device Connection 10
5.2 Configuration 10
5.3 Application Pattern 10
5.4 PC Tool Setup and Control 13
6. Web-based UI configuration 27
7. Package Contents 35
Partilink Technology Co., Ltd Copyright @ 2016
2
1. Introduction
HDMI over IP Extender is made for point to point, point to multi-point, multi- point to multi-point and screen wall broadcast including RS-232 and IR control extension. Easy to install and with networking 10/100 BASE-T switch hub as well as CAT-5 cable for building up the extension or broadcast system.
*** P2K-HL3E1-P supports power over Ethernet
Partilink Technology Co., Ltd Copyright @ 2016
3
2. Features & Application
RS-232 bi-directional extension 6 bits switch for 64 stream channel selection HDCP compliant and Blu-Ray ready Supports IR extension Automatic or manual EDID configuration Networking environment under 10/100 BASE-T
Switch hub and CAT-5 cable
Point to point extension, unicast, multicast and
screen wall system
Point to point extension via CATx without
Ethernet switch up to 100M
Supports PC tool Ethernet control Power over Ethernet version is provided
(P2K-HL3E1-P).
Partilink Technology Co., Ltd Copyright @ 2016
4
3. Specifications
P2K-HRSL3E1 P2K-HRSL3E1-P 1080p HDMI Extender over IP
P2K-HRSL3E1 P2K-HRSL3E1-P Transmitter
P2K-LHRS1E3 P2K-LHRS1E3-P Receiver
VIDEO INPUT
HDMI Type-A female connector
None
VIDEO OUTPUT
HDMI Type-A female connector for loop through
HDMI Type-A female connector
IR
3.5mm phone jack for IR emitter to control video source device
3.5mm phone jack for IR receiver cable to receive remote signal
COMPRESSION
H.264 compression video format Full HD encoder/ decoder MP3 compression audio format stereo 192Kbps encoder/ decoder Media stream up to 18Mbps
HDMI INPUT RESOLUTION
1080p 60/50, 1080p 30/25, 1080i 60/50,720p 60/50, 480i 60/50, 480p 60/50
HDMI OUTPUT RESOLUTION
1080p 60/50, 1080i 60/50, 720p 60/50, 480i 60/50, 480p 60/50
AUDIO FORMAT
Stereo 192Kbps
IP PROTOCOL
TCP, UDP, RTSP, RTP, DHCP, IGMP, Multicast, IPV4
LAN PORT
RJ-45 connector for 10/100 BASE-T CAT-5 extension
SERIAL
DB-9 female connector for RS-232
POWER INPUT
2.0mm power jack for DC5V/2A RJ-45, Power over Ethernet 36V~57V / 7W in (PoE model only)
OPERATING TEMPERATURE
OPERATING HUMIDITY
5%~90% RH
POWER ADAPTER
AC in 100~240V (50~60Hz), DC5V/2A out
ESD
ESD protection air gap
DIMENSION (W x D x L)
130 x 82 x 30.25 mm ( L x W x H )
WEIGHT
290g per transmitter or receiver unit
** Product specifications are subject to change without notice.
4. Hardware Description
Partilink Technology Co., Ltd Copyright @ 2016
5
P2K-HRSL3E1 /P2K-HRSL3E1-P (TX)
1. 2.0 mm power jack for DC5V2A power input.
2. LAN port, RJ-45 connector for 10/100 BASE-T CAT5 extension.
3. HDMI Type-A female connector for loop through video output.
4. HDMI Type-A female input connector.
5. 3.5mm phone jack for IR emitter to control video source device.
6. DB-9 female connector for RS-232 cable bi-directional remote extension
7. Display group indication.
8. Group configuration, 6 bits switch for 64 stream channel selection.
Partilink Technology Co., Ltd Copyright @ 2016
6
9. Reset button.
Channel
DIP SWITCH
00
000000
01
100000
~ ~ 63
111111
Dimension
Transmitter
P2K-HRSL3E1 P2K-HRSL3E1-P
Shell
Metal
Width
110mm/130mm
Height
30mm
Depth
86mm
Weight
290g
Partilink Technology Co., Ltd Copyright @ 2016
7
P2K-LHRS1E3 /P2K-LHRS1E3 –P (RX)
1. 2.0 mm power jack for DC5V2A power input.
2. LAN port, RJ-45 connector for 10/100 BASE-T CAT5 extension.
3. HDMI Type-A female connector for video output.
4. 3.5mm phone jack for IR receiver cable to receive signal from remote controller.
5. DB-9 female connector for RS-232 bi-directional remote extension.
6. Display group indication.
7. Group configuration, 6 bits switch for 64 stream channel selection.
Partilink Technology Co., Ltd Copyright @ 2016
8
8. Reset button.
Channel
DIP SWITCH
00
000000
01
100000
~ ~ 63
111111
9. Dimension
Receiver
P2K-LHRS1E3 P2K-LHRS1E3-P
Shell
Metal
Width
110mm/130mm
Height
30mm
Depth
86mm
Weight
290g
Partilink Technology Co., Ltd Copyright @ 2016
9
5. Installation
5.1 Device Connection
1. Set up the group of transmitters with the
correspondent receivers for signal extension and display.
2. Connect between the Sources and
transmitters, the Displays and receivers with HDMI cables.
3. Connect CAT-5 cables with transmitters to the
Ethernet Switch inputs, and CAT-5 cables with receivers to the Ethernet Switch outputs.
4. Powering the transmitters and receivers with
DC5V power adapter.
5. Turn the Source on and hit play button.
6. Connect the IR emitter cable with transmitters
and the IR receiver cable with the receiver to control the Source remotely.
Partilink Technology Co., Ltd Copyright @ 2016
10
5.2 Configuration
5.3 Application Pattern
■ Unicast
Partilink Technology Co., Ltd Copyright @ 2016
11
Multicast
Partilink Technology Co., Ltd Copyright @ 2016
12
Screen Wall
Partilink Technology Co., Ltd Copyright @ 2016
13
5.4 PC Tool Setup and Control
The P2K-HL3E1 / P2K-HL3E1-P is a Ethernet based system, administrator can control the system by PC via the PC tool
IPTV_Control_Center.exe” to set up and control
the system.
To inquire about the software, visit Partilink
website to download the PC tool or simply contact us by email.
Download Site: “Technical Service”
http://www.partilink.com/index.php/en/download-2
Service Email: sales@partilink.com
1. The default IP address of the P2K-HRSL3E1 /
P2K-HRSL3E1-P is B class Networking :168.254.xxx.xxx, please set up the IP address of the connected PC as static IP, such as 169.254.xxx.xxx and the sub mask as 255.255.0.0.
Partilink Technology Co., Ltd Copyright @ 2016
14
2. Connect the PC with the Ethernet Switch of
application site to enter.
3. Activate the tool “IPTV_Control_Center.exe” to
search and setup.
Partilink Technology Co., Ltd Copyright @ 2016
15
4. Enter the tool in “Device Scan Page” and click
on “Start Scan” to search for the connected devices. The connected devices will be indicated in “Output Window” area. (Illustration [1] [2])
5. Adjust transmitter settings in “TX Setup Page”
Partilink Technology Co., Ltd Copyright @ 2016
16
and receiver settings in “RX Setup Page”.
(Illustration [3])
6. TRANSMITTER SETTINGS
In the “TX Setup Page”, please select the TX
device which is required to setup on the “TX
Device Selection” and the relevant setting
information of the selected TX device will be shown in the “TX Device Info” area (Illustration [4] [5])
Partilink Technology Co., Ltd Copyright @ 2016
17
Partilink Technology Co., Ltd Copyright @ 2016
18
The setting functions of the transmitter clarified below, please set up based on the request of the application site.
IP Setup:
Setting the static IP of the selected TX. **We suggest activating the DHCP automatic IP assignment to avoid the conflicts of IP address. (Illustration [6])
Video Bitrate:
Setting the resolution’s video bitrate of each
group on the selected TX (Illustration [7])
Down Scale Setup:
Set the resolution downscale of each group on the selected TX. (Illustration [8])
Group ID:
Set the selected TX group ID, with maximum up to 64 groups from 0 to 63. (Illustration [9])
Partilink Technology Co., Ltd Copyright @ 2016
19
UART Baudrate:
Set the baud rate of RS-232 extension on the selected TX. (Illustration [10])
Stream Output Path:
Set the selected TX video output path. Options include “Loopthrough and Network
Output”, “Disable Network Output”, “Disable Loopthrough Output” and “Disable All Video
Output” to activate the HDMI output on the
transmitter and receiver simultaneously or separately. (Illustration [11])
MAC Address:
Set the selected TX MAC address with 12 digits and hexadecimal base, values is limited to 0~F. Please use legal MAC address to avoid conflict with other devices. (Illustration [12])
Partilink Technology Co., Ltd Copyright @ 2016
20
Device Name:
Set the selected TX name for identification. Up to 32 digits is accepted for device name setting. (Illustration [13])
7. RECEIVER SETING In the “RX Setup Page”, please select RX device which is required to setup on the RX Device Selection” and the relevant setting information of selected RX device will be shown in RX Device Info” section (Illustration [14] and [15])
Partilink Technology Co., Ltd Copyright @ 2016
21
Partilink Technology Co., Ltd Copyright @ 2016
22
The setting functions of the receiver clarified below, please set up based follow the request of the application site.
IP Setup:
Set the static IP of the selected RX(Illustration [16])
Screen Mode:
Choose whether to display the video on the selected RX or not. (Illustration [17])
OSD Information:
Set the OSD display mode on the selected RX, OSD display modes including Info Display Auto Mode, Infor Display On Mode and Info Display Off Mode. (Illustration [18])
UART Baudrate:
Set the baud rate of RS-232 extension on the selected RX. (Illustration [19])
MAC Address:
Set the selected RX MAC address with 12
Partilink Technology Co., Ltd Copyright @ 2016
23
digits and hexadecimal base, values is limited to 0~F. Please use the legal MAC address to avoid conflicts with the devices. (Illustration [20])
Group ID:
Set the selected RX to the group ID for streaming between the corresponding TX and RX, maximum up to 64 groups from 0 to 63 (Illustration [21])
Device name: Set the selected RX name for
identification. Up to 32 digits is accepted for the device name setting. (Illustration [22])
8.
Partilink Technology Co., Ltd Copyright @ 2016
24
NOTICE: Please Reboot the device after setting up the P2K-HL3E1 system via the PC tool and the previous setting via hardware or software will be ignored, the system will auto detect to update the latest setting and apply as the start mode. (Illustration [23] and [24])
Partilink Technology Co., Ltd Copyright @ 2016
25
9. When the system is setting incompletely, click
on “Factory Reset” to recover the initial default
of the system. (Illustration [25])
Partilink Technology Co., Ltd Copyright @ 2016
26
10. The P2K-HL3E1 / P2K-HL3E1-P system can be firmware upgraded via PC. To upgrade the
firmware please click on “Firmware Upgrade”
and select the path to save the firmware and
click on “Upgrade TX Firmware” to accomplish
upgrade version. (Illustration [26] and [27])
Partilink Technology Co., Ltd Copyright @ 2016
27
6. Web User Interface Configuration
6.1 TX System
6.1.1 TX Log-in
Log-in page will pop up when entering TX system
Default User Name and Password:
User Name: ite000 Password: 123456
Partilink Technology Co., Ltd Copyright @ 2016
28
Update User Name and Password
System provides 1 set user name and
password. If user doesn’t want user
default, please put preferred User Name and Password as follows. Then hit “Confirm” to change user name and password.
6.1.2 Version Information
Below shows firmware information and network setting of TX
Partilink Technology Co., Ltd Copyright @ 2016
29
Note: Please also set TX and all RXs in the same group by setting DIP SWITCH.
6.1.3 Multicast
To support several more than one RX
enable “Multicast” for multicast function.
(see below)
Partilink Technology Co., Ltd Copyright @ 2016
30
6.1.4 Upgrade firmware
Please download firmware at Partilink website and put it in local folder.
Download Site: “Technical Service”
http://www.partilink.com/index.php/en/download-2
To upgrade firmware please hit “Upgrade” under “Upgrade Firmware”, and choose the
location of firmware file. Then hit ”Upgrade” again to load firmware and the system will start firmware upgrade automatically.
Partilink Technology Co., Ltd Copyright @ 2016
31
6.1.5 Reset
Encoder Reset: To reboot Encoder simply
click on “Encoder Reset” button.
Partilink Technology Co., Ltd Copyright @ 2016
32
Reboot Device: To reboot whole device
please click on “Reboot” button.
6.2 RX System
6.2.1 RX Log-in
Log-in page will pop up when entering RX system
Default User Name and Password:
User Name: admin Password: 123456
Partilink Technology Co., Ltd Copyright @ 2016
33
6.2.2 Upgrade firmware
Please download firmware from Partilink website and put it in a local folder.
Download Site: “Technical Service”
http://www.partilink.com/index.php/en/download-2
To upgrade firmware please hit “Upgrade” under
“Upgrade Firmware”. Please choose the location of
firmware file. Hit “Upgrade” again to load firmware and the system will start firmware upgrade automatically.
Partilink Technology Co., Ltd Copyright @ 2016
34
6.2.3 Reboot
To reboot the device please click on “Reboot”
button. It will show message as “Reload page
after 10 seconds” in the bottom of the page.
Partilink Technology Co., Ltd Copyright @ 2016
35
7. Package Contents
1. HRSL3E1 / HRSL3E1-P HDMI Extender
over IP transmitter (1)
2. LHRS1E3 / LHRS1E3-P HDMI extender
over IP receiver (1)
3. DC5V 2A power adapter, one comes with
transmitter and one comes with receiver (2)
4. IR receiver cable comes with receiver (1)
5. IR emitter cable comes with transmitter (1)
6. User manual (1)
Partilink Technology Co., Ltd Copyright @ 2016
36
www.partilink.com
Loading...