Contents
Parry-British Built for Purpose
IN258-3
Contents ........................................................................................................................................... 1
Product Overview ............................................................................................................................ 2
Safety Instructions ............................................................................................................................ 3
Installation Instructions ................................................................................................................ 4-6
Operating Instructions ................................................................................................................... 6-7
Cleaning Instructions ....................................................................................................................... 8
Maintenance Instructions ................................................................................................................. 9
Fault Finding .................................................................................................................................. 10
Replacement Parts .......................................................................................................................... 11
Natural Gas Conversion Instructions............................................................................................... 12
LPG Gas Conversion Instructions .................................................................................................... 13
Conversion Procedure................................................................................................................ 14-16
Technical Information .................................................................................................................... 17
Service Information ....................................................................................................................... 18
Exploded View ................................................................................................................................ 19
Parts List ................................................................................................................................... 20-21
Warranty Information..................................................................................................................... 22
Disposal & Recycling ...................................................................................................................... 23
Parry Catering Equipment (Midlands) Ltd, Town End Road, Draycott, Derby, DE72 3PT.
Sales Tel: 01332 875544 Fax: 01332 874455

Parry-British Built for Purpose
IN258-3
Product Overview
The Parry GB6/GB6P natural gas/LPG 6 burner ovens are robust yet refined. With great
versatility the units are ideally suited for a range of catering environments. Exceling in
aesthetic appeal, functionality and performance, both units feature six powerful burners
and a double-door gas oven. They come with duplex chassis for added rigidity and heavy
duty cast-iron pan supports. The units are easy to clean with vitreous enamel lining,
provided with castors fitted as standard, two of which are braked.
Dimensions (w x d x h) mm
KW -- Natural
KW – Propane
Gas Input Pressure – natural
Gas Input Pressure – Propane
Can be converted using conversion kit
The units lead the industry in:
Design and aesthetic appeal
Performance
Power
Functionality
After sales support

Parry-British Built for Purpose
IN258-3
Safety Instructions
THIS APPLIANCE IS ONLY FOR PROFESSIONAL USE AND MUST ONLY BE USED BY QUALIFIED
PEOPLE.
Attention should be drawn to the fact that parts of this unit by necessity, will get VERY HOT,
and will cause burns if touched accidentally. Therefore, it is the responsibility of the
supervisor or equivalent to provide SUITABLE PROTECTIVE CLOTHING for the user.
THIS APPLIANCE MUST BE FITTED AND TESTED BY A REGISTERED FITTER BEFORE USE.
The unit should be installed in compliance with the INSTALLATION INSTRUCTIONS and the
NATIONAL REGULATIONS in force at the time. Particular attention should be paid to the Gas
Safety (Installation and Use) Regulations and the Health and Safety at Work Act.
All commercial gas catering equipment is recommended to be mounted below an extraction
canopy. Please consult a ventilation engineer or refer to Guidelines DW172 to calculate the
ventilation requirements for cooking areas containing different pieces of gas catering
equipment.
Each appliance requires a flow of fresh air for combustion. Under no circumstances should
air vents on the appliances, or air vents installed by the fitter in the room of the appliance to
supply combustion air, be altered or omitted in any way.
To prevent shocks, all appliances whether gas or electric, must be earthed.
ANY GAS CONVERSIONS NEEDED TO BE MADE TO THE PRODUCT MUST BE CARRIED OUT
BY A GAS SAFE REGISTERED ENGINEER
To avoid scratching the highly polished exterior surface of this equipment whilst in transit,
the protective film on the exterior surfaces has NOT been removed.
It is IMPORTANT that this protective film is peeled off before the equipment is used.

Parry-British Built for Purpose
IN258-3
Installation Instructions
Before installation check data plate on rear of unit to ensure appliance is suitable for gas
supply available.
During installation provision must be provided for combustion air to the appliance through
base and rear of appliance. This should not be blocked at any time. This appliance should be
installed with adequate ventilation to prevent the occurrence of unacceptable
concentrations of substances harmful to health in the room in which it is installed.
POSITIONING
The appliance must not be installed on or against combustible surfaces – minimum
clearances must be:
Rear 150mm (6”)
Sides 150mm (6”)
Hotplate to combustible material 1525mm (60”)
All local fire regulations should be observed.
It is recommended that the appliance be sited below a ventilating hood preferably of the
extractor type incorporating a grease filter.
The cooker is manufactured with four castors two of which are braked. Caution should be
taken when manipulating or moving the unit. The appliance should be attached to a wall with
a chain to restrict the movement of the unit once connected to the gas supply. When the unit
is installed in position the brakes should be on.
Ensure the appliance is level, by placing a spirit level on the shelf in the oven, not on the pan
supports. All four castors are adjustable. To alter the height of the unit, loosen the locking
grub screw with an M3 allen key.
Next turn the large nut on the wheel assembly to either raise or lower the unit. When you are
happy with the height, tighten the locking grub screw with the M3 allen key.

Parry-British Built for Purpose
IN258-3
Installation Instructions
The oven doors are held shut by adjustable roller catches. When installing the appliance
ensure the catches are set to allow the door to close firmly. To adjust the catch, use a
screwdriver to press in roller to below the plate, turn clockwise to adjust downward, and
anti-clockwise to lift the roller.
GAS CONNECTION
The size of the supply pipe should be no less than 3/4” B.S.P. and an easily accessible
isolation tap fitted close to the appliance in the gas line. Although a rigid connection is
recommended. An approved armoured flexible pipe may be used in conjunction with a
straining cable.
Before the appliance is commissioned the gas, safety regulations require that all
connections on the gas line are tested for gas soundness between the gas meter and the
appliance.
All packing and protective film must be removed from panels etc. prior to commissioning
the appliance. All gas appliances must be fitted by a competent person to gas safety
regulations in force.
Gas hoses used to connect the appliance to the gas supply must be of the correct
specification for the gas and pressure of the appliance. The gas hose must comply with the
national requirements in force, and be CE marked, of a metal braided construction suitable
for commercial catering equipment. The hoses should be periodically examined and
replaced as necessary
The tube or hose shall be fitted such that there are no sharp bends or torsional strain which
may cause damage or failure of the tube or hose, especially near the end fittings. Torsional
strain can be prevented by the use of internal unions, swivel joints, etc. The bend radius
should not exceed that stated by the Manufacturer. The hose should not touch the ground
and should be no longer than 1.5m long.
A manual valve should be positioned upstream of the tube or hose unless the connection
fitting incorporates a self-sealing quick release coupling.

Parry-British Built for Purpose
IN258-3
Installation Instructions
Where a quick release coupling is used for horizontal travel such as in commercial catering
appliances it is advisable that the coupling is facing downwards to prevent the ingress of
debris and ensure the hose is formed in to a smooth curve.
All units should have a restraining cable fitted preventing the unit from being pulled away
from the wall and causing the gas hose to become disconnected accidentally.
Operating Instructions
Operating the hob
All burners are fitted with flame failure devices.
1. To light hob unit turn knob to
2. Press in and ignite gas with a match, keep knob held in for 15-20 seconds.
3. Release knob, gas should stay lit, if gas goes out repeat stage 2
4. The burner is now on full gas, to turn gas down, turn knob anti-clockwise, this is the
lowest setting, which is factory set.
5. To turn burners off, turn knob clockwise all the way round.
Parry recommends that the hob is used only with pans that have a minimum diameter of
120mm, and up to a maximum of 295mm diameter. This ensures that there is satisfactory
combustion, and the pan is stable as it sits on the finger of the pan support.
Operating the oven
1. To light oven, open doors, turn oven knob to approximate gas mark 5 and hold tap
knob in, at the same time press the piezo ignitor button on bottom of the oven.
2. After pressing button 2-3 times burner should light.
3. Keep oven knob depressed for 15-20 seconds.
4. Release knob and flame should remain lit, if not repeat above sequence.
5. If burner goes out refer to fault finding chart.
6. When burner stays on oven is ready for use, select gas mark required, turn knob to
setting, oven flame will decrease when desired temperature is reached.

Parry-British Built for Purpose
IN258-3
Operating Instructions
Please take care when opening and closing the doors of an oven that has been turned on.
Surfaces and handles will get hot. The surfaces within the oven chamber will be very hot so
it is advisable to wear oven gloves to protect from burns that may be incurred from
touching hot surfaces within the oven.
We advise these appliances should not be left unattended while switched on.
These appliances are for professional use by qualified people only. There are no user
serviceable parts.
It is recommended that the sealed top plate is cleaned regularly to prevent build-up of fat
and grease.
There are three shelf positions in the oven, the following guide is only intended as a guide to
temperature in the centre of the oven. It is strongly recommended that the user makes note
of best results, temperatures can vary as much as 20˚c hotter at top of oven and 30˚c cooler
at the bottom of the oven.
These temperatures are measured in an empty oven.
Cooking Chart – the following chart is for guidance only.
MILK PUDDING
BAKED CUSTARD
SHORT CRUST
PLATE TARTS
FLAKY

Parry-British Built for Purpose
IN258-3
Cleaning Instructions
The appliance should be cleaned after every use.
Allow unit to cool down before cleaning
Wipe down the unit using hot soapy ware and a soft cloth, do not use abrasive
materials.
The wire shelves and the vitreous enamel bottom tray can be removed for cleaning, but
the lower tray must be in position when the appliance is in use.
Stainless steel cleaners maybe used and cleaning instructions on the product must be
adhered to.
Never clean the unit with water jets.

Parry-British Built for Purpose
IN258-3
Maintenance Instructions
Ensure the appliance is isolated from the power supply before installing, cleaning or
maintaining the appliance.
Maintenance and service must only be undertaken by a qualified electrician.
Parry Catering provides a complete after-sales service by offering the sales of spare parts
directly to customers. Buying spares straight from the manufacturer allows customer to
experience exceptional value and speedy delivery on all spare parts.
For more information on buying spares visit:
www.parry.co.uk/parry-commercial-catering-spares

Parry-British Built for Purpose
IN258-3
Incorrect flame picture, flame
lift or noisy burner
Incorrect burner pressure,
Blocked or partially blocked
injector.
Inadequate ventilation.
Burner faulty/corroded/blocked
Check/adjust burner pressure
Check /clean injector,
Check ventilation.
Check / clean burner and
replace as necessary.
Burners will not stay alight
Faulty connection at
thermocouple-valve, incorrectly
located
Remake connection, reposition
thermocouple
Burner goes out when turned
to “low”
Burner ring/cap not correctly
located, or low pressure
Relocate and check pressure at
test point.
Dirt or grease broken or loose
connection
Clean reconnect / replace
H.T.Lead
Thermocouple out of position.

Parry-British Built for Purpose
IN258-3
Replacement Parts
For Gas Safe Engineers only
HOB TAP- Remove pan supports, pull off control knobs and unclip fascia panel.
Disconnect burner supply tube and thermocouple. Undo the 2 screws securing the tap to
the rail. Check sealing washer and replace if necessary. Assemble in reverse order.
HOB BURNER/THERMOCOUPLE – Remove Pan Supports and Burner caps. Remove the solid
top tray.
Disconnect thermocouple from rear of tap. Undo locknut on burner mounting channel.
Assemble in reverse order.
OVEN THERMOSTAT - Proceed as for hob tap. Slide thermostat phial from housing inside
oven. Remove through hole in the top of the oven on right hand side. Assemble in reverse
order.
OVEN THERMOCOUPLE - Remove the bottom oven tray. Inside the oven disconnect the
thermocouple from the extension piece. Undo locknut holding thermocouple to oven
burner. Assemble in reverse order. Ensure locknut is securely tightened.
OVEN BURNER/IGNITON - Remove oven base. Disconnect oven supply tube, H.T. lead and
thermocouple. Burner is held in by 2 screws. Piezo spark generator is secured by a locknut.
Electrode secured to burner bracket by centre screw.

Parry-British Built for Purpose
IN258-3
Natural Gas – Conversion Instructions
For use with models with the following serial numbers
These instructions can be used for converting from LPG to Natural Gas
LPG units are designed and tested in accordance with all current regulations enforced to run
on the following gases only
Nat Gas G20 @ 20mbar 8” W.G.
PLEASE NOTE
This conversion must be carried out by a Gas Safe Registered Engineer.
This conversion kit includes
NAT GAS Hob valve bypass screw
stamped with 85
NAT GAS Hob Burner Injector
stamped with 185
NAT GAS Oven valve bypass
screw stamped with 70
NAT GAS oven burner injector
stamped with 220

Parry-British Built for Purpose
IN258-3
LPG – Conversion Instructions
For use with models with the following serial numbers
These instructions can be used for converting from Natural Gas to LPG
LPG units are designed and tested in accordance with all current regulations enforced to run on
the following gases only
Propane G31 @ 37mbar 14.8” W.G.
PLEASE NOTE
This conversion must be carried out by a Gas Safe Registered Engineer.
This conversion kit includes
LPG hob valve bypass screw
stamped 50
LPG hob burner injector stamped
105
LPG oven valve bypass screw
stamped 50
LPG oven burner injector
stamped 150

Parry-British Built for Purpose
IN258-3
Conversion Procedure for GB6
Warning
Ensure the appliance is isolated from the gas supply before commencing conversion
Remove pan support and
burner caps / aluminium
discs.
Remove the solid top
plates.
Using a 10mm spanner or
nut runner remove burner
injector. Replace with
injector from conversion
kit.
Replace solid top plates,
aluminium burner plates
and burner caps.

Parry-British Built for Purpose
IN258-3
Remove the tap knobs to
allow the fascia to be
removed.
Open doors and
underneath the fascia
unscrew the 2 x securing
screws. Pull fascia away
from the bottom.
Disconnect HT lead from
piezo.
Remove low rate screws
in hob tap bodies and
replace with low rate
screw from the
conversion kit.
Replace low rate screw
in oven thermostat body
from the conversion kit.
Converting the oven
burner.
Remove shelves and
bottom tray.
Unscrew the 15mm nut
on the jet that goes into
the burner.
Unwind anti-clockwise
the jet out of the burner.

Parry-British Built for Purpose
IN258-3
Replace jet with the jet
for the required gas.
Refit gas pipe and tighten
up the 15mm nut.
Connect the unit back to
the gas supply and
test for gas soundness.
Replace the facia and
knobs accordingly.
When comversion is complete addix new data label and gas type label supplied with the
conversion kit, detailing type of gas and pressure.

Parry-British Built for Purpose
IN258-3
Technical Information
Per Hob Burner
AIR FLOW RATE FOR COMBUSTION
20m³/HR

Parry-British Built for Purpose
IN258-3
Service Information
This appliance should be routinely serviced to prolong its lifetime. Parry recommends that
the appliance is serviced every 12 months by a Parry authorised engineer. Failure to service
your product within the initial 12 month warranty period will cause the 24 month warranty
to become void.
If the supply cord becomes damaged, it must be replaced by the manufacturer, it’s service
agent, or a similarly qualified person.
Enhanced 2 Years Warranty
Parry Catering (Midlands) Ltd offer an enhanced warranty of two
years (including parts and labour) on all of the Parry manufactured
products. To take advantage of this you should register you warranty
by logging onto the company website and filling out our simple form.
www.parry.co.uk/the-parry-warranty
If you have any issues with your product and wish to request a
warranty call you can contact our friendly team who will organize a
Parry approved service engineer to attend and fix your problem.
All warranty requests can be sent to
[email protected]
alternatively call our warranty department for technical
assistance on
01332 875544

Parry-British Built for Purpose
IN258-3

Parry-British Built for Purpose
IN258-3
Hob Burner Complete with Injector
Carriage
Hob Injector (Nat)
Hob Injector (LPG)
HOBINJECT185
HOBINJECT105
Hob Bypass Screw (Nat)
Hob Bypass Screw (LPG)
Oven Bypass Screw (Nat)
Oven Bypass Screw (LPG)

Parry-British Built for Purpose
IN258-3
Thermocouple Extension Lead
High Temperature Sleeving (Length
mm)
Oven Injector (Nat)
Oven Injector (LPG)
75mm Swivel Braked Castor
Adjuster Boss for Castors
Door Seal Dart Clips (18 Per unit)

Parry-British Built for Purpose
IN258-3
Warranty Information
Not covered under warranty
Fault due to incorrect installation, poor maintenance
or equipment abuse.
Resetting of equipment or circuit breakers.
Faulty electrics – e.g. customer’s plug socket, plug,
wiring, junction box fault, wrong fuse.
Products must be serviced within the first 12
months to be eligible for the 2 year warranty
Product not covered by warranty if combustible
materials have been used, e.g. plastic trays.
Foil used on racks, blockages and lime scale issues.
Failure to grant access for pre-arranged service
call.
Equipment that has been set up or used incorrectly
e.g. dishwasher detergents, levelling and setting up
of doors on a six burner cooker.
Excessive carbon build-up on griddle plates or
overuse of lava rock on chargrills. (Recommended
use by Parry no more than 2kg.)
All of the above points are not covered by
warranty and any costs incurred, because of the
above, will be forwarded to the parties responsible
for placing the call.
The manufacturer’s warranty is only valid in the UK
mainland. Northern Ireland, Western Isles, Inner
Hebrides and Islands are parts only warranty. Please
be aware that the warranty starts from the date of
purchase from Parry and not the sale or installation
date of the equipment.
To be eligible for a 2 year warranty, products must be
serviced at least once within the first 12 months of
purchase.
All service calls will be carried out between 8am
and 5pm, Monday to Friday.
Your warranty is invalid if your equipment has not
been installed in accordance with the
manufacturer’s instructions. The misuse, alteration
or unauthorised repairs of the equipment will also
invalidate the warranty.
During the warranty period it is at Parry’s
discretion whether to repair or replace the
equipment.
The warranty only applies if the equipment has
been used in a professional manner following the
manufacturer’s instructions and maintenance
guidelines.
The warranty covers defects in the material and
component failure only. We are not liable for trading
loss, loss of perishable items, water damage or loss
due to injury or fire damage.
Please ensure you have referred to the
manufacturer’s instruction before placing a warranty
call.
Contact our warranty department on 01332 875544
for technical assistance.
Please have your model number ready before calling.
All warranty requests must be submitted to
Failure to pay any warranty charges will result in your
warranty being put on hold until the bill has been
settled. Any issues regarding the raised charges should
be put in writing to our warranty department for
further investigation.
Register your product by visiting our website
www.parry.co.uk

Parry-British Built for Purpose
IN258-3
Disposal & Recycling
The packaging should be disposed of according to regulations in force.