Parker TLU248HB Schematic

Page 1
LCD
TLU248HB
Page 2
CONTENT
7cm
PARTS LIST
MODEL PART NUMBER DESCRIPTION SPECIFICATIONPHOTO
Caution.................................................................................................2
Technical Specifications.......................................................................6
Circuit Diagram...................................................................................14
Exploded View....................................................................................26
Parts List ............................................................................................30
Note: This manual is the latest at the time of printing,and does not include the modification which may be made after the printing, by the constant improvement of product.
TLU248HB
PK-TLU-248-RM-HB
PK-TLU-248-MB-HB
PK-TLU-248-PW-HB POWER BOARD LS2402003 VER1.0
PK-TLU-248-KEYB-HB
PK-TLU-248-TCW-HB
PK-TLU-248-SPK-HB
PK-TLU-248-RCB-HB
4cm
REMOTE CONTROL REMOTE CONTROL
MAIN BOARD
KEYBOARD
T.COM, WIRE
(LVDS)27PIN
SPEAKER
4 X 7 cm
RECEIVER BOARD
CLAA215FA01
MT8223.2A
T15.022011-00R
T.COM, WIRE (LVDS)27PIN
4Ώ / 5W
T15.035011-02R
TLU248HB
1
TLU248HB
30
Page 3
The lightning flash with arrowhead symbol, within an equi-
lateral triangle, is intended to
alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclo sure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
PRECAUTIONS DURING SERVICING
1. In addition to safety, other parts and assemblies are specified for conformance with such regulations as those applying to spurious radiation. These must also be replaced only with specified replace­ments. Examples: RF converters, tuner units, antenna selection switches, RF cables, noise-blocking capacitors, noise-blocking filters, etc.
2. Use specified internal Wiring. Note especially:
1) Wires covered with PVC tubing
2) Double insulated wires
3) High voltage leads
3. Use specified insulating materials for hazardous live parts. Note especially:
1) Insulating Tape
2) PVC tubing
3) Spacers (insulating barriers)
4) Insulating sheets for transistors
5) Plastic screws for fixing micro switches
4. When replacing AC primary side components(transformers, power
TLU248HB
29
TLU248HB
2
Page 4
cords, noise blocking capacitors, etc.), wrap ends of wires securely about the terminals before soldering.
5. Make sure that wires do not contact heat generating parts (heat sinks, oxide metal film resistors, fusible resistors, etc.)
6. Check if replaced wires do not contact sharply edged or pointed parts.
7. Make sure that foreign objects (screws, solder droplets, etc.) do not remain inside the set.
MAKE YOUR CONTRIBUTION TO PROTECT THE ENVI­RONMENT
Used batteries with the ISO symbol
for recycling as well as small accumulators(rechargeable batteries), mini-batteries (cells) and starter batteries should not be thrown into the garbage can. Please leave them at an appropriate depot.
WARNING:
Before servicing this TV receiver, read the SAFETY INSTRUCTION and PRODUCT AFETY NOTICE.
SAFETY INSTRUCTION
The service should not be attempted by anyone unfamiliar with the necessary instructions on this apparatus. The following are the neces­sary instructions to be observed before servicing.
1. An isolation transformer should be connected in the power line between the receiver and the AC line when a service is performed on the primary of the converter transformer of the set.
2. Comply with all caution and safety related provided on the back of the cabinet, inside the cabinet, on the chassis or LCD panel.
3. When replacing a MAIN PCB in the cabinet,always be certain that all protective are installed properly such as control knobs,adjustment covers or shields, barriers, isolation resistor networks etc.
4. When servicing is required, observe the original lead dressing. Extra precaution should be given to assure correct lead dressing in the high voltage area.
TLU248HB
3
TLU248HB
28
Page 5
5. Keep wires away from high voltage or high tempera ture compo­nents.
6. Before returning the set to the customer,always perform an AC leakage current check on the exposed metallic parts of the cabinet,such as antennas, terminals,screwheads, metal overlay, control shafts, etc., to be sure the set is safe to operate without danger of electrical shock. Plug the AC line cord directly to the AC outlet (do not use a line isolation transformer during this check). Use an AC voltmeter having 5K ohms volt sensitivity or more in the following manner. Connect a 1.5K ohm 10 watt resistor paralleled by a 0.15μF AC type capacitor, between a good earth ground (water pipe, conductor etc.,)and the exposed metallic parts, one at a time.Measure the AC voltage across the combination of the 1.5K ohm resistor and 0.15 uF capacitor. Reverse the AC plug at the AC outlet and repeat the AC voltage measurements for each exposed metallic part.The mea­sured voltage must not exceed 0.3V RMS. This corresponds to 0.5mA AC. Any value exceeding this limit constitutes a potential shock hazard and must be corrected immedi­ately. The resistance measurement should be done between accessible exposed metal parts and power cord plug prongs with the power switch "ON". The resistance should be more than 6M ohms.
TLU248HB
PRODU
CT S AFETY NOTICE Many electrical and mechanical parts in this apparatus have special safety-related characteristics. These characteristics are offer passed unnoticed by visual spection and the protection afforded by them cannot necessarily be obtained by using replacement components rates for a higher voltage, wattage, etc. The replacement parts which have these special safety characteristics
27
TLU248HB
4
Page 6
3
CIRCUIT(SCH)
are identified by marks on the schematic diagram and on the parts list. Before replacing any of these components,read the parts list in this manual carefully. The use of substitute replacement parts which do not have the same safety characteristics as specified in the parts list may create shock,
fire, or other hazards. Must be sure that the ground wire of the AC inlet is connected with the ground of the apparatus properly.
TLU248HB E xploded View D raw ing
TLU248HB
5
TLU248HB
26
Page 7
2
TECHNICAL SPECIFICATIONS
FEATURES
Image Resolution: 1366 x 768 (HD)
Brightness: 300cd/m2
USB Port compatible with MP3 audio and JPG photos
Dynamic Contrast Ratio: 30,000:1
Viewing Angle: 170° / 170°
Response Time: 5 ms
TV System: NTSC / PAL M / PAL N
Audio Power: 5W x 2
MTS Stereo / SAP
HDMI Input (1)
Power: 100-240V 50/60Hz
Net Weight: 4.5 Kg Dimensions: 531 x 353 x 73 mm
TLU248HB
25
TLU248HB
6
Page 8
TLU248HB
7
TLU248HB
24
Page 9
TLU248HB
23
TLU248HB
8
Page 10
3
CIRCUIT(SCH)
TLU248HB
9
TLU248HB
22
Page 11
3
CIRCUIT(SCH)
TLU248HB
21
TLU248HB
10
Page 12
TLU248HB
11
TLU248HB
20
Page 13
3
CIRCUIT(SCH)
SERVICE
Lcd tv trouble shooting NOTICE:Before repair the board,make sure the software is correct or upgrade the correct software. Warning:If upgrade fail,such as power off during upgrading,the flash rom must be replaced.Power Supply Trouble
Remote control unit
TLU248HB
19
TLU248HB
12
Page 14
CIRCUIT DIAGRAM
1 BLOCK DIAGRAM
2. circuit(SCH)
1. BLOCK DIAGRAM
PCB failure analysis
1. CONTROL: a. Abnormal noise on screen. b. No picture.
2. MAIN (VIDEO): a. Lacking color, Bad color scale. b. No voice. c. No picture but with signals output, OSD and back light. d. Abnormal noise on screen.3. POWER: No picture, no power output.
Basic operation of LCD-TV
1. After turning on power switch, power board sends 5Vst-by Volt to Micro Processor IC waiting for ON signals from Key Switch or Remote Receiver.
2. When the ON signal from Key Switch or Remote Receiver is detected, Micro Processor will send ON Control signals to Power. Then Power sends (5V,3.3V,1.8V and Vs ON) to PCBs working. This time inverter will send signals to display back light,OSD on the panel and start to search available signal sources.If the audio signals input, them will be amplified by Audio AMP and transmitted to Speakers.
3. If some abnormal signals are detected (for example: over volts, over current,over temperature and under volts), the system will be shut down by Power off.
TLU248HB
13
TLU248HB
18
Page 15
Basic Operat ions & C ircuit D esc ription Main Elec tric C omponent s (1).MODULE: There is 1 pcs panel.
(2).SIGNAL PROCESS There are PCB including: 1 pcs Main board, 1 pcs Keypad board, 1 pcs Remote Control Receiver board
(3).POWER & Inverter board There is 1 pcs PCB inverter. There is 1 pcs 12V/3A DC adapter.
PCB Function
1.Power: Convert the low DC voltage +12V to high AC voltage to drive the back­light.
Circuit(SCH)
Double click to view it.
3
CIRCUIT(SCH)
2.Main(Video InterFace) board: (1).Convert TV RF signal to video and audio signal (2).Convert the audio to audio amplify and output to the speaker. (3).Decode the video signal(TV,CVBS,S-VIDEO)from analog to digital signal. Convert the Video signals(TV,CVBS,S-VIDEO) and graphics signal(HDMI VGA, YPbPr) from internace to progressive. (4).Convert the Digital to fit the panel display mode and output of the LVDS signal to panel.
3. KEY board To get the main button control on LCD TV as SOURCE,MENU,CHANNEL+,CHANNEL-, VOL+,VOL-, STANDBY functions.
4. Remote Control board Receive the remote signal and active for the control.
TLU248HB
17
TLU248HB
14
Page 16
TLU248HB
15
TLU248HB
16
Loading...