Wiring diagram
60
80
100
125
20
0
-20
-40
-40 - +85°C
40
Connector, -A
AMP Superseal 1.5
Connector, -D
Deutsch, DT04
TGSS 740
Installation TGSS 740
Publ.no: HY33-5005-IS/US
Ed. 02/2012
IQAN master or VMM
system modules
13
1. FREQ_OUT
2. POWER (+12Vdc)
3. GROUND
4
3
1. FREQ_OUT
2. GROUND
3. POWER (+12Vdc)
1
2
4. DIGITAL_OUT
Mating connector: available from manufacturer
Housing: 282087-1
Contacts: 183025-1 (3 req’d)
Seals: 281934-2 (3 req’d)
Boot (optional): 880811-2
Unit may be
mounted facing
forward or backward
35°
It is important for the sight line of the doppler signal to be as unobstructed as possible.
Interference with the doppler signal can lead to false or erratic speed readings.
1000
1 m [39”]
.3 m [12”]
35°
Mating connector: 5031113
NOTICE
Connectors must be properly installed
to meet environmental specification.
• Sealing plugs must be inserted in
all unused pin positions.
35°
1697
959
Speed vs. output diagram
Hz
MAX
MIN
0.3
(0.5)
44.0
(70.0)
MPH
(kph)
(2004/108/EC)
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR
SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL
INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide
product and/or system options for further investigation by users having technical expertise. It is important that you analyze
all aspects of your application, including consequences of any failure, and review the information concerning the product or
system in the current product catalogue. Due to the variety of operating conditions and applications for these products or
systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products
and systems and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing,
are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
For further information see:
HY33-5005-IB/US Instructions TGSS 740
Eng.no: IS-TGSS-201202-05

Mounting TGSS 740
Any error in the mounting angle will directly affect the Doppler accuracy. At 35° nominal, an
error of 1° is approximately a 1% error in speed measurement. Post installation calibration
should be done to remove errors due to bracket alignment tolerances and vehicle levelness.
45.7
[1.80]
6.6
[.26]
71.9
[2.83]
90°
GROUND LEVEL
The mounting plate should be at least 6.35 mm (¼”) steel and the length kept short to
MOUNTING PLATE
BEAM PATTERN
35°
minimize vibration. Sample mounting plate dimensions are shown below.
[7.0]
The TGSS should be secured to the mounting plate with bolts in all 3 bolt holes using 6 mm
Hex Head bolts and locking washers.
The bolts should be tightened to 5.4-7.3 Nm (48-65 in lbs).
Appropriate length bolts are routed from the underside of the unit through the mounting
plate and tightened into the shock absorbers on the unit’s base. The bolts should engage the
threads in the shock absorbers to a maximum depth of 6.35 mm (¼”).
NOTICE
At completion of installation, the validation steps
outlined in ‘HY33-5005-IB/US Instructions TGSS
740’ should be followed.
[3.14”]
58.9
[2.32”]
41.1
[1.62”]
94.4
[3.72”]
41.4
[1.63”]
267
[10.5]
5X R 6,35
[.250]
35.0°
NOTICE
If the area dimensions are exceeded:
• increase material thickness to help reduce
susceptibility to vibration.
178
[7.0]
MIN 6,35IN
[.250]
112.2
[4.42”]
104.4
[4.11”]
RUBBER
SHOCK MOUNTS
standard variants
length* = 200 mm
[7.9”]
*- other variants
may have
different length
units = mm
[inch]