Parker HASV08R Operating Manual

Operating Manual
Thank you for your choice of Parker product. Please read this operating manual carefully and use the product correctly. Keep this operating manual in case questions arise about this product in the future. If this operating manual becomes unreadable or lost, consult our distributors or Parker sales offices.
The following safety precautions are provided to prevent damage and injury to personnel and to provide instructions on the correct usage of this product. These precautions are classified into 3 categories: “CAUTION”, ”WARNING”, and “DANGER” according to the severity of possible injury or damage and the likelihood of such injury or damage. Be sure to comply with all precautions. Also comply with safety regulations such as ISO 4414(*1), Industrial Safety and Health Law, and High Pressure Gas Safety Law.
Danger:
Indicates an impeding hazardous situation which may arise due to improper handling or operation and could result in serious personal injury or death.
Warning:
Indicates a potentially hazardous situation which may arise due to improper handling or operation and could result in serious personal injury or death.
Caution:
Indicates a potentially hazardous situation which may arise due to improper handling or operation and could result in personal injury or property-damage-only accidents.
*1 ISO 4414: Pneumatic fluid power recommendations for the application of equipment to
transmission control system.
This product is designed for air blowgun.
Do not use it for other purposes.
Use compressed air from an air compressor.
Do not use air from a high pressure tank or any other gases.
Do not blow air from air blowgun towards
personnel or animals.
Direct air blow or substance blown by air blow can potentially cause injury for humans or animals.
Wear safety glasses and ear plugs.
Regardless of the use of this product, wear safety glasses and earplugs when operating an air blowgun. Without proper protection, injury to eyes due to blown dust or noise induced deafness would be potentially caused.
Do not disassemble or modify this product.
Disassembling or modification may cause safety accidents in addition to operation failure.
Attach a pipe fitting or joint properly.
If a pipe fitting or joint are attached improperly, it may cause danger such as hose whip due to unplugged piping. Confirm the connection of hose, tube or coupler joint is tight as well as the connection to this product prior to use.
Do not use for medical equipment or cooking equipment
This product contains a small amount of lubricant. If there is concern for contamination due to lubricant, do not use.
Specifications
Fluid Compressed air Pressure Range 3.5 to 8 bar Maximum Flow
*1
1300L/min (5 bar)
Ambient Temperature
*2
10 to 50 degree C
Pulse Adjustment Range 5 to 15Hz
Port Size
IN
Rc1/4 (BSPT1/4)
OUT
R1/4 (BSPT1/4)
Weight 155 g
*1 “Maximum Flow” indicates the flow capacity of this product, and
actual flow consumption is depending on the atta ched air blowgun.
*2 If the temperature is under the specified temperature, pulse blow
may become unstable. Please use it as continuous blow temporally for a while to reach specified temperature. This product works correctly within the specified ambient temperature.
Connection
1. Before Piping, thoroughly flush the inside of each pipe to remove chips, machining oil, and dust etc. If sealing tape is used for the thread, leave 1.5 to 2 thread turns unwrapped. Do not use liquid sealant. It has possibility to contaminate the product and may cause malfunction.
2. When installing piping or a joint, prevent penetration of chips or sealing agent. Also tightening torque should be within the range
Warning
Bits of seal tape may enter the flow passage and cause malfunction.
Leave space of 1.5 -2 turns
It can be used by cutting in half.
Cut with knife.
Not good
Good
Air Saver Unit for Air Blowgun
“Air Saver Module” HASV08R
9IM-E009-a
IssuedJan.15.2016
Air blowgun
“Air Saver Module” HASV08R
Reference blowgun: Parker LEGRIS Part Number: 0659 00 13 (Sold Separatel
y
)
Caution
<Example of attachment>
Push-in fitting or joint such as coupler
(Sold Separately)
indicated below.
Port Size Tightening Torque (N・m) R, Rc1/4 12 to 14
3. An air filter (Nominal filtration rating of 5 micron or smaller) must be placed upstream of piping. There is no need for additional lubrication.
4. Attach the piping towards the direction of air flow described on the body. If it is opposite direction, this product does not work.
5. This product must be attached directly to an air blow gun. If connected with any part such as coupler, it has the possibility to decrease the capability due to pressure loss.
6. This product is not water & drip proof. Do not install this product in a place with direct water contact (rain, etc.). Also install this product in a place without dew condensation or direct sunlight.
Product Function
Pulse Adjustment Screw This is a throttle valve for pulse ON time adjustment (Approx.5 to 15 Hz). When tightening this screw clockwise with flat-bladed screwdriver, the air ON time will be longer. When loosening the screw counter clockwise, the air ON time will be shorter. The air OFF time is fixed for approx. 30ms. Adjust the air ON time in accordance with using air blowgun or object. Control angle is approx. single rotation of the screw. When tightening at the end of clockwise, it will stop air output, however it is not malfunction.
Pulse/ Continuous Switching Button Press this button when requiring continuous blow. When pushing this button, air blows continuously. To keep continuous blow, press this button and turn the button 90 degrees. To release from this mode, press this button and turn counter clockwise for pulse blow mode.
Dimensions
Notes for Usage
Discharge drain from upstream air filter periodically. If periodic
drain discharge is difficult, Parker recommends setting up an air filter with automatic drain.
Maintenance compressor periodically. If sludge, which is
produced in compressor oil, enters pneumatic equipment, it will cause operation failure of pneumatic equipment. Coalescing filter removes oil and sludge which cannot be removed by air filter. Parker recommends setting up a coalescing filter.
Effect of Pulse Blow
In many factories, air blow accounts for more than 50% of total compressed air consumption. Pulse blow can be a measure for saving energy by reducing the consumption of compressed air while maintaining the same capability of air blow operation.
Hole machining, tap, chip removing of complex shape work Removing stuck dust or viscous liquid Blowing at narrow space Reducing load of compressor Energy saving activity
Pulse blow is especially effective for works listed above, however it is not for all applications. There is a possibility to reduce the removal effectiveness depending on the air blowgun. Parker recommends attaching to an air blowgun that has nozzle diameter bigger than I.D.2mm and low pressure loss. Also, for the case of using reduced pressure for air supply, installing this product without regulator enables a low energy loss circuit, which provides improved blow effectiveness compared to the current circuit.
Kuroda Pneumatics Ltd
(Parker Hannifin Automation Division Japan)
10243 Kamakazu, Asahi city, Chiba 289-2505, Japan
http://www.parkerkuroda.com
http://www.parker.com
10Hz
Air Blow Gun Connecting Port (R1/4)
Pulse Control Trimmer
[Note]
- Please contact our distributors or Parker for after-sales service.
- Please keep this operating manual.
15Hz
Pressure Supply Port (Rc1/4)
Vent Hole


Pulse/ Continuous Switching Button





Flow
Flow
Current Circuit
Pulse Blow
Air Consum
p
tion L/min
Air Consum
p
tion L/min
Time (sec)
Time (sec)
Pulse Adjustment Screw (ON Time Control)
Pulse/ Continuous Switching button
Time
Time
Loading...