Parker D31DW*EE, D*1VW*EE, D31NW*EE Operating Instructions Manual

Bulletin HY11-5715-681/UK
Pilot Operated Proportional DC Valve
Operating instructions
Series D31DW*EE, D31NW*EE, D*1VW*EE
Design series 92 II 2 G c T4 Gb
-20 °C < T
a < +60 °C
Parker Hannifin Manufacturing Germany GmbH & Co. KG
Hydraulic Controls Division Europe Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+49) 181 99 44 43 0 E-mail: infohcd@parker.com Copyright © 2013, Parker Hannifin Corp.
2
Pilot Operated Proportional DC Valve
Series D*W*EE Explosion Proof
Operating Instructions
Parker Hannifin Corporation
Hydraulics Group
D_W_EE_92 5715-681 UK.indd CM 07.05.13
Note
This document and other information from Parker-Hannifin Corpo­ration, its subsidiaries and authorized distributors provide product or system options for further investigation by users having techni­cal expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assur­ing that all performance, endurance, maintenance, safety and warn­ing requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsid­iaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifica­tions provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applica­tions and reasonably foreseeable uses of the components or systems.
Pilot Operated Proportional DC Valve
Series D*W*EE Explosion Proof
Operating Instructions
3
Parker Hannifin Corporation
Hydraulics Group
D_W_EE_92 5715-681 UK.indd CM 07.05.13
0. EC declaration of conformity 4
1. Introduction 5 Ordering code 6
Technical data 8
Characteristic curves 9 Pilot oil 11 Dimensions 12 Name plate 15
2. Safety instructions 15
Symbols 15 Marking, Name plates 15 Work on the valve 16
3. Important information 16
Correct use 16 Common instructions 16 Liability 16 Storage 16
4. Installation 17
Scope of delivery 17 Installation 17 Electrical connection 17 Operation limits 17 Pressure fluids 17
5. Operating instructions 20
Air bleeding of hydraulic system 20 Filter 20 Flushing 20
6. Maintenance 20
7. Troubleshooting 21
A1 Extract from standards/directives 22
A2 User guide – Solenoid 23
A3 Type-examination certificate – Solenoid 27
A4 Declaration of conformity - Solenoid 32
A5 Mounting instruction cable gland 33
Contents Page
4
Pilot Operated Proportional DC Valve
Series D*W*EE Explosion Proof
Operating Instructions
Parker Hannifin Corporation
Hydraulics Group
D_W_EE_92 5715-681 UK.indd CM 07.05.13
0. EC declaration of conformity
EG KONFORMITÄTSERKLÄRUNG DECLARATION OF CONFORMITY DECLARATION DE CONFORMITÉ
im Sinne der EG-Richtlinie 94/9/EG vom 23.03.1994 und mit den zu ihrer Umsetzung erlassenen Rechtsvorschriften Pursuant to European Directive 94/9/EC dated 23 March 1994 and statutory provisions relating to its implementation Dans le sens de la directive 94/9/CE datée du 23 3 1994 et des prescriptions légales promulguées quant à son application,
Wir Parker Hannifin GmbH We Nous
Anschrift Gutenbergstraße 38 address DE-41564 Kaarst adresse
erklären, dass die in der Betriebsanleitung beschriebenen, explosionsgeschützt ausgeführten vorgesteuerten Wegeventiles hereby declare that, as described in the operation instructions, the explosion-proof pilot operated DC valve déclarons que, comme décrit dans ce mode d’emploi, les soupapes antidéflagrantes type distributeur à commande pilotée
der Serie D31DW*EE, D31NW*EE, series D*1VW*EE de la série
Geräte im Sinne des Artikels 1 (3) der RL 94/9/EG sind und die grundlegenden Sicherheits- und Gesundheitsanforderungen gemäß Anhang II der Richtlinie 94/9/EG erfüllen. are equipment as defined in Article 1 (3) of Directive 94/9/EC and comply with the essential health and safety requirements set out in Annex II of Directive 94/9/EG. correspondent aux appareils dans le sens de l’article 1 (3) de la directive RL 94/9/CE et qu’ils remplissent les exigences fondamentales relatives à la sécurité et la santé selon l’annexe II de la directive 94/9/CE.
Die grundlegenden Sicherheits- und Gesundheitsanforderungen werden erfüllt in Übereinstimmung mit folgenden Normen: The essential health and safety requirements are met in accordance with the following standards: Les exigences relatives à la sécurité ainsi qu’à la santé sont remplies en conformité avec les normes suivantes:
EN 1127-1 EN 13463-1 EN 13463-5 EN 982
Die Kennzeichnung der Geräte enthalten folgende Angaben: The marking of the equipment contains the following information: Les marquages des appareils contiennent les indications suivantes :
II 2 G c T4 Gb
-20 °C Ta +60 °C
Der korrekte Gebrauch der Geräte bei Installation und Betrieb wird vorausgesetzt. Details zum korrekten Gebrauch (ein­schließlich Explosionsschutz) sind in der Betriebsanleitung zu finden. It is assumed that the equipment will only be installed and operated in accordance with correct use. Details of correct use can be found in the operating instructions incl. explosion protection. Il est obligatoire d’installer et d’utiliser les appareils de la manière correcte. Le mode d’emploi contient des détails pour l’utilisation correcte, comprenant la protection antidéflagrante.
Kaarst, 03.12.2012
Technischer Leiter QM-Beauftragter Technical manager QM officer Directeur technique Responsable qualité Hansgeorg Kolvenbach Wolfgang Bausch
Pilot Operated Proportional DC Valve
Series D*W*EE Explosion Proof
Operating Instructions
5
Parker Hannifin Corporation
Hydraulics Group
D_W_EE_92 5715-681 UK.indd CM 07.05.13
D31DW
D91VW
D31NW D41VW
D91VW D111VW
1. Introduction
The D*1*W*EE with explosion proof solenoids are based on the standard D*1*W series. The specif­ic solenoid design allows the usage in hazardous environments.
The explosion proof class is
Ex mbe II T4 Gb for use in zone 1 (conform to ATEX). All explosion proof solenoids are DC design. The
valves for AC operate with integrated rectifier. The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D91VW NG25 (for port diameter up to 32 mm) D111VW NG32 All valves are piloted by a D1VW valve. The mini-
mum pilot pressure must be ensured for all oper­ating conditions of the directional valve.
Additionally spools with a P to T connection in the de-energized position need an external pressure supply (external inlet) or an integral check valve.
6
Pilot Operated Proportional DC Valve
Series D*W*EE Explosion Proof
Operating Instructions
Parker Hannifin Corporation
Hydraulics Group
D_W_EE_92 5715-681 UK.indd CM 07.05.13
Series Spool type
3 position spool
Code Spool type
a 0 b
001
2)
002
2)
003
3)
004
3)
005
3)
006
3)
009
1) 2)
011
3)
015
3)
016
3)
021
3)
022
3)
2 position spool
Code Spool type
a b
020
2)
030
2)
3 position spool
Code Spool position
C
2)
3 positions. Spring offset in position “0“. Operated in position “a“ or “b“.
Standard Spool type 009
E
2)
Operated in position “a“.
Operated in position “b“.
2 positions. Spring offset in position “0“.
F
2)
Spring offset in
position “b“.
Spring offset in
position “a“.
2 positions. Operated in position “0“.
K
2)
Operated in position “b“.
Operated in position “a“.
2 positions. Spring offset in position “0“.
M
2)
Spring offset in
position “a“.
Spring offset in
position “b“.
2 positions. Operated in position “0“.
R
3)
No centre in
offset position.
No centre in
offset position.
2 positions, detent. Operated in position “0“ or “b“.
S
3)
No centre in
offset position.
No centre in
offset position.
2 positions, detent. Operated in position “0“ or “a“. No center in offset position.
2 position spools
Code Spool position
B
2)
Spring offset in position “b“. Operated in position “a“.
D
3)
Detent, operated in position “a“ or “b“. No center or offset position.
H
2)
Spring offset in position “a“. Operated in position “b“.
Spool
position
Code Bore Size Feature D31DW Ø11mm NG10 D31NW Ø11mm NG10 High flow D41VW Ø20mm NG16 D91VW Ø32mm NG25
D111VW Ø50mm NG32
Ordering code
Pilot Operated Proportional DC Valve
Series D*W*EE Explosion Proof
Operating Instructions
7
Parker Hannifin Corporation
Hydraulics Group
D_W_EE_92 5715-681 UK.indd CM 07.05.13
Solenoid
options:
Explosion
proof
Ex mbe II
Solenoid
voltage
Pilot oil
supply
and drain
options
Accessories
Further spool types and solenoid voltages on request.
Connection:
Explosion proof with
cable glands
Seals
Code Seal
N NBR
V FPM
Code Solenoid voltage
J 24V =
N 230 V/50 Hz P 110 V/50 Hz
Code Inlet Outlet
1 Internal External
2 External External
3
4)
Integral
check valve
External
4
5)
Internal Internal
5 External Internal
6
4)
Integral
check valve
Internal
Code Accessories
ohne
Standard valve
w/o accessories
3A Pilot choke, meter-out
3B Pilot choke, meter-in
3C
Pilot with pressure
reducing valve
3D
6)
Stroke adjustment
side B
3E
6)
Stroke adjustment
side A
3F
Stroke adjustment
side A and B
3R
meter-out / pressure
reducing valve
1T
meter-in / pressure
reducing valve
Design
series
(not required
for ordering)
1)
Consider specific spool position.
2)
All sizes (D31, D41, D 91, D111) available
3)
Only D31, D41, D91 available.
4)
Not for D31DW and D111VW available.
5)
Not for spools 002, 009 available.
6)
Only D31, D41, D91 available.
E
E
8
Pilot Operated Proportional DC Valve
Series D*W*EE Explosion Proof
Operating Instructions
Parker Hannifin Corporation
Hydraulics Group
D_W_EE_92 5715-681 UK.indd CM 07.05.13
60 / 40 (50/60) 95 / 65 150 / 170 470 / 390 55 / 40 (50/60) 75 / 65 110 / 170 320 / 390 55 / 40 (50/50) 60 / 65 90 / 170 210 / 390 55 / 40 (50/50) 60 / 65 85 / 170 200 / 390 40 / 30 (30/50) 75 / 55 130 / 155 450 / 375 35 / 30 (30/50) 65 / 55 90 / 155 300 / 375 35 / 30 (30/50) 40 / 55 70 / 155 190 / 375 35 / 30 (30/50) 40 / 55 65 / 155 180 / 375
General
Design Directional spool valve Actuation Solenoid Series D31DW D31NW D41VW D91VW D111VW Size NG10 NG10 NG16 NG25 NG32 Weight (1/2 solenoids) [kg] 6.0 / 6.6 7.6 / 8.1 9.7 / 10.3 17.9 / 18.6 67.4 / 68.0 Mounting interface DIN 24340
A10
DIN 24340
A10
DIN 24340
A16
DIN 24340
A25
DIN 24340
A32
ISO 4401 ISO 4401 ISO 4401 ISO 4401 ISO 4401
NFPA D05 NFPA D05 NFPA D07 NFPA D08 NFPA D10
CETOP RP 121-H Mounting position unrestricted, preferably horizontal Ambient temperature [°C] -20...+60 MTTF
D
value [years] 75
Hydraulic
Max. operating pressure [bar] P, A, B: 350; T: 140 Fluid Hydraulic oil in accordance with DIN 51524 / 51525 Fluid temperature [°C] -25 ... +60 Viscosity permitted [cSt] / recommended [cSt] /
[mm²/s] [mm²/s]
2.8...400
30...80 Filtration ISO 4406 (1999); 18/16/13 Flow max. [l/min] 150 170 300 700 2000 Leakage at 350 bar (per flow path) [ml/min] up to 100* up to 150* up to 200* up to 800* up to 5000* *depending on spool Opening pressure integral check valve [bar] n.a. see p/Q
diagram
see p/Q diagram
see p/Q diagram
n.a.
Minimum pilot supply pressure [bar] 5 7 5
Static / Dynamic
Step response at 95 % [ms] Energized / De-energized DC solenoids Pilot pressure 50 bar
100 bar 250 bar 350 bar
AC solenoids Pilot pressure 50 bar
100 bar 250 bar 350 bar
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 135 °C possible Protection class
, Ex mbe II T4 Gb, IP66 (plugged and mounted correctly)
Code
J N P
24 V = 230/50 Hz 110/50 Hz
±10 ±10 ±10
1.0 0.12 0.25 24 24 24
Supply voltage / ripple [V] Tolerance supply voltage [%] Current consumption [A] Power consumption [W] Solenoid connection Box with M20x1.5 entry for cable glands. Solenoid identification as per
ISO 9461. Wiring min. [mm²] 3 x 1.5 recommended Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
Technical data
Pilot Operated Proportional DC Valve
Series D*W*EE Explosion Proof
Operating Instructions
9
Parker Hannifin Corporation
Hydraulics Group
D_W_EE_92 5715-681 UK.indd CM 07.05.13
D31DW and D41VW
Spool Code
Curve number
P-A P-B P-T A-T B-T
D3 D4 D3 D4 D3 D4 D3 D4 D3 D4 001 3 1 3 1 1 4 1 5 002 3 1 3 2 4 6 1 4 1 6 003 3 1 4 2 1 5 1 6 004 3 1 3 1 1 5 1 5 005 3 2 4 2 1 3 1 5 006 3 1 3 2 1 3 1 6 007 4 1 3 1 6 1 4 1 5 009 3 2 3 9 8 8 1 7 1 10 011 3 1 3 1 1 4 1 5 014 3 1 4 1 6 1 4 1 5 015 4 1 3 2 1 4 1 6 016 4 2 3 2 1 3 1 5 020 3 3 4 5 1 3 1 5 021 4 2 3 8 1 2 – 022 3 8 4 2 1 3 026 3 3 3 5 – 030 3 2 1 3 1 6 1 7 054 2 3 6 7
Flow curves
The flow curve diagram shows the flow versus pressure drop curves for all spool types. The rel-
Spool
Code
Curve number
P-A P-B P-T A-T B-T 001 3 3 2 5 002 3 3 7 4 3 003 2 3 4 4 004 2 3 4 4 005 2 4 1 4 006 8 9 7 9 009 4 6 6 4 10 011 3 3 2 4 015 2 2 1 4 016 4 3 2 4 020 6 4 3 6 021 7 8 – 022 4 9 – 030 5 3 2 5
D31NW
All characteristic curves measured with HLP46 at 50 °C.
evant curve number for each spool type, operat­ing position and flow direction is given in the ta­ble below.
10
Pilot Operated Proportional DC Valve
Series D*W*EE Explosion Proof
Operating Instructions
Parker Hannifin Corporation
Hydraulics Group
D_W_EE_92 5715-681 UK.indd CM 07.05.13
Flow curves / Integral check valve
Spool
Code
Curve number
P-A P-B P-T A-T B-T
D9 D11 D9 D11 D9 D11 D9 D11 D9 D11 001 3 5 2 5 3 4 5 1 002 2 5 1 5 1 5 3 4 5 1 003 4 2 3 6 – 004 4 3 3 5 – 005 1 2 4 5 – 006 2 2 4 6 – 007 3 1 7 3 5 – 009 4 3 8 3 9 2 4 3 10 1 011 3 2 3 5 – 014 1 2 8 3 5 – 015 3 3 4 5 – 016 3 3 4 5 – 020 6 5 5 5 6 3 8 1 021 5 10 3 – 022 10 5 5 – 026 6 5 – 030 3 5 2 5 3 4 5 1 054 4 5 3 5 3 4 5 1
D91VW and D111VW
Integral check valve in the P port
Mounting an integral check valve in the P port is necessary to build up pilot pressure for valves with P to T connection and internal pilot oil supply. The pressure difference at the integral check valve (see performance curves) is to be added to all flow curves of the P-port of the main valve. Direction­al valves with an integral check valve are available for the series D31NW and D41VW.
Flow curve D41VW
Flow curve D91VWFlow curve D31NW
Pressure drop p [bar]
Flow Q [l/min]
100
200 300 400
500
600 700
10 9 8 7 6 5 4
14 12
10
8
6
4
2
0
0
D91VW
Pilot Operated Proportional DC Valve
Series D*W*EE Explosion Proof
Operating Instructions
11
Parker Hannifin Corporation
Hydraulics Group
D_W_EE_92 5715-681 UK.indd CM 07.05.13
D111VW
D91VW
D41VW
Pilot oil inlet (supply) and outlet (drain) D31DW
D31NW
All orifice sizes for standard valves