Parker D 1FC, D FC Operation Manual

Page 1
Bulletin MSG11-5715-686/UK
Operation Manual Series D*FC / D*1FC
D*FC Design 10 D*1FC Design 10
Proportional Directional Control Valves
Parker Hannifin Manufacturing Germany GmbH & Co. KG
Industrial Systems Division Europe Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+49) 181 99 44 43 0 E-mail: valvesisde@parker.com Copyright © 2019, Parker Hannifin Corp.
Page 2
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
WARNING — USER RESPONSIBILITY
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.
D_FC 5715-686 UK 07.02.2019
2
Parker Hannifin Corporation
Page 3
Proportional DC Valves
Operation Manual
Content Page
1. Introduction 4
Ordering code D*FC 4
Ordering code D*1FC 5
Name plate example 6
Characteristics of valve driver 6
Block diagram of integral electronics 7
Technical data 8
Signal flow diagram 9
Scope of supply
Important information 10
Information on the process of technical changes 10
Information on warranty and liability 10
CE mark 10
Personnel requirements 10
Compliance with other rules and instructions 10
2. Safety 10
Safety instructions 10
Use of the product 11
Limits of use 11
Contaminations 11
Remaining risks 11
3. Use of the product 12
Transport 12
Storage 12
Commissioning 12
Pressure fluids 13
Electrical connection 13
Electrical interfacing 15
ProPxD parametrizing software 20
Operation 23
Service/maintenance 23
Air bleeding of hydraulic system 23
Filter 23
Flushing 23
Decommissioning 23
Disposal 23
Trouble shooting 23
4. Product information 24
Other applicable standards/rules 24
Accessories / spare parts 25
Series D*FC, D*1FC
10
D_FC 5715-686 UK 07.02.2019
3
Parker Hannifin Corporation
Page 4
Proportional DC Valves
Operation Manual
1. Introduction
D*FC
Main connector (always on A-side of main stage)
Air bleeding
Manual override
Ordering code D*FC
Series D*FC, D*1FC
D F C 9 3
Parametrizing connection
DC
valve
Nominal
size
Proportional
control
High
dynamics
Spool
type
(see
catalogue)
Spool
position
Drain port Y
plugged
1)
4)
Code Nominal size
1 NG06 / CETOP 03 3 NG10 / CETOP 05
Spool position on
Code
A
B
C
1)
On power down the spool moves in a defined position.
B – T with pressure drops above 120 bar or contamination in the hydraulic fluid.
2)
Approx. 10 % opening, only zero lapped spools and underlap spools.
3)
Only for overlapped spools.
4)
Needs to be removed at tank pressure >35 bar.
5)
Please order connector separately.
D_FC 5715-686 UK 07.02.2019
power down
2)
2)
3)
This cannot be guaranteed in case of single flow path on the control edge A – T resp.
4
Command
signal
Spool/
body
design
Seal Design
Electrical
options
series
(not required
for ordering)
Code Electronic options
0 6 + PE 5 11 + PE 7 6 + PE with enable
Code Signal Function
B 0...±10 V
0...±20 mA0...+20 mA
E
K 0...±10 V
S 4...20 mA
0...+10 V P -> A
P -> A
0...+10 V P -> B
12...20 mA P -> A
Code Seal
N NBR V FPM
Parker Hannifin Corporation
5)
Page 5
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
D*1FC
Parametrizing connection
Ordering code D*1FC
D 1 F C C
Direct.
control
valve
Nominal
size
NG06
pilot
Proportional
control
Integrated
electronics
with position
feedback
Function
(see catalogue)
Flow
(see catalogue)
Spool position
on power down
A
TAPB
connection
(see catalogue)
(see catalogue)
Main connector (always on B-side of main stage)
B
Pilot
Command
signal
Seal Design
Electrical options
Manual override
Valve
options
2)
series
(not required
for ordering)
Code Nominal size
3 NG10 / CETOP 05 4 NG16 / CETOP 07
9 1)NG25 / CETOP 08
11 NG32 / CETOP 10
Code Seal
N NBR V FPM
Code Signal Function
B 0...±10 V
0...±20 mA0...+20 mA
E
K 0...±10 V
S 4...20 mA
D_FC 5715-686 UK 07.02.2019
0...+10 V P -> B
P -> B
0...+10 V P -> A
12...20 mA P -> A
Code Valve options
Standard für
0
spool type B, E, R
2) 3)
8
Monitor switch
Hybrid valve 24 V
L
normaly closed for
spool type Z
Code Electronic options
0 6 + PE 5 11 + PE 7 6 + PE with enable
1)
With enlarged connections Ø 32 mm.
2)
Not for D111FCZ*.
3)
Monitor switch for hybrid valves: code 8 includes options of code L
(24 V normally closed).
5
Parker Hannifin Corporation
Page 6
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
Name plate example
nominal pressure hydr. spool symbol order code
Parker D*FC and D*1FC proportional directional control valves have an integral electronics. Differ­ent flow sizes as well as command signal options are available to achieve an optimal adaption for different applications.
Characteristics of valve driver
The described integral electronic driver combines all necessary functions for the optimal operation of the valve. The most important features are:
• digital circuit design
• high dynamic constant current solenoid control
• differential input stage with various command signal options
• four quadrant ramp function
• MIN adjustment for deadband compensation
• MAX adjustment to match the command signal span to the valve operating range
D_FC 5715-686 UK 07.02.2019
6
Parker Hannifin Corporation
Page 7
Operation Manual
Block diagram of integral electronics D*FC, Code 0 (6+PE)
Proportional DC Valves
Series D*FC, D*1FC
D*1FC, Code 0 (6+PE)
D*FC, Code 5 (11+PE)
D*FC, Code 7 (6+PE with enable) D*1FC, Code 7 (6+PE with enable)
D*1FC, Code 5 (11+PE)
D_FC 5715-686 UK 07.02.2019
7
Parker Hannifin Corporation
Page 8
Proportional DC Valves
Operation Manual
Technical Data
General
Design Proportional directional control valve,
Actuation Proportional solenoid Size D*FC D*1FC
Mounting interface DIN 24340/ISO 4401/CETOP RP121/NFPA Mounting position unrestricted Hysteresis [%] <0.1 Ambient temperature [°C] -20...+60 MTTFD value Weight [kg] D*FC NG06 = 3.4 / NG10 = 7.7
Vibration strength [G]
Hydraulic
Operating pressure [bar] D*FC: Ports P, A, B 350, port T max. 35; 210 (external drain);
Fluid Hydraulic oil according to DIN 51524 ... 535, other on request Fluid temperature [°C] -20...+60 (NBR: -25...+60) Viscosity permitted recommended Filtration ISO 4406; 18/16/13
Electrical
Duty ratio [%] 100 Protection class IP65 acc. EN 60529 (with correctly mounted plug-in connector) Supply voltage Us [VDC] 18...30, electric shut-off at < 17, ripple < 5 % eff., surge free Current consumption max. [A] 2.0 (D1FC, D*1FC), 3.5 (D3FC) Pre-fusing [A] 2.5 (D1FC, D*1FC), 4.0 (D3FC) Command signal Uc options Ic
Differential input voltage max.
Adjustment ranges Min [%] 0...50 Max [%] 50...100 Ramp [s] 0...32.5 Interface RS232C, parametrizing connection 5pole Enable signal (code 1/5/7) [V] 5...30 Diagnostic signal [V] +10...0...-10 / +12.5 error detection, rated max. 5 mA EMC EN 61000-6-2, EN 61000-6-4 Central connection Code 0//7: 6+PE acc. EN 175201-804
Cable specification [mm²]
Cable length max. [m] 50
1)
[cSt]/[mm2/s] [cSt]/[mm2/s]
direct operated (D*FC), pilot operated (D*1FC)
NG06 (CETOP 03) / NG10 (CETOP 05) NG10 (CETOP 05) / NG16 (CETOP 07) / NG25 (CETOP 08) / NG32 (CETOP10)
[years] D*FC: 150, D*1FC: 75
D*1FC: NG10 = 9.0 / NG16 = 12.5 / NG25 = 21.0 / NG32 = 68.5 10 Sinus 5...2000 Hz acc. IEC 60068-2-6 10 (RMS) Random noise 20...2000 Hz acc. IEC 60068-2-36 15 Shock acc. IEC 60068-2-27
port Y max. 35 D*1FC: pilot oil internal P, A, B, X 350; T, Y 210 pilot oil external P, A, B, T, X 350; Y 210
20…400
30...80
[V]
Codes B, K: +10...0...-10, ripple < 0.01 % eff., surge free, Ri = 100 kOhm
[mA]
Code S: 4...12...20, ripple < 0.01 % eff., surge free, Ri = <250 Ohm < 3.6 mA = enable off > 3.8 mA = enable on (acc. NAMUR NE43)
[mA]
Code E: +20...0...-20, ripple < 0.01 % eff., surge free, Ri = <250 Ohm
[V]
Code 0/7: 30 for terminal D and E against PE (terminal G)
[V]
11 for terminal D and E against 0 V (terminal B)
[V]
Code 5: 30 for terminal 4 and 5 against PE (terminal W)
[V]
11 for terminal 4 and 5 against 0 V (terminal 2)
Code 5: 11+PE acc. EN 175201-804 Code 0/7: 7 x 1.0 (AWG16) overall braid shield
[mm²]
Code 5: 8 x 1.0 (AWG20) overall braid shield
Series D*FC, D*1FC
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
1)
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the
valve electronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
D_FC 5715-686 UK 07.02.2019
8
Parker Hannifin Corporation
Page 9
Operation Manual
Command
Ramps
eedbac
positio
eedbac
current
eedbac
current
Signal flow diagram
Dither
Proportional DC Valves
Series D*FC, D*1FC
Solenoid A
Solenoid B
PI
P6
P5
Freq.
Ampl.
PID
P7
Min
Min A
A-
S6
S5
A+
D_FC 5715-686 UK 07.02.2019
S7
B+
E17
Option
Command
P8
S8
E19
Min B
B-
Break
P4
P3
P1
Max
Max B
Max A
Zero
k
F
9
k
n
F
k
A
B
F
Enable
Parker Hannifin Corporation
Basic Mode
Expert Mode
Page 10
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
Scope of supply
Please check immediately after receiving the valve, if the content is matching with the specified scope of supply. The delivery includes:
• valve
• operation manual
The central connector assembly has to be ordered separately and is not included in the delivery.
Please check the delivery immediately after receiving the shipment for apparent dam­ages due to shipping. Report shipment losses at once to the carrier, the insurance company and the supplier!
Intended usage
This operation manual is valid for proportional direc­tional control valves D*FC/D*1FC series. Any dif­ferent or beyond it usage is deemed to be as not intended. The manufacturer is not liable for warranty claims resulting from this.

Information on the process of technical changes

We reserve the right to make technical changes as a result of further development of the product described in these operating instructions. Figures and drawings in these instructions are simplified depictions. As a result of developments, improve­ments and changes to the product, it is possible that the figures are not fully consistent with the valve in operation. The technical details and dimensions are non-binding. They may not form the basis of any claims. Copyright reserved.
Information on warranty and liability
The manufacturer does not assume liability for damage due to the following failures:
• incorrect mounting / installation
• improper handling
• lack of maintenance
• operation outside the specification
CE mark
The CE mark appears on the main nameplate. If the product is installed as part of a larger machine, this larger machine is in turn subject to EU directives and must therefore obtain a general CE mark for the machine as a whole. The machine must not enter circulation in the EU until this is done. The legal requirements corresponding to the CE mark can be found in section "Other applicable standards / rules".
Personnel requirements
The product may only be used, installed, removed, operated and maintained by specialist personnel. For the purposes of these instructions, a specialist is defined as someone who, on the basis of their education, expertise and professional experience, is able to correctly evaluate and carry out the tasks and duties assigned to him/her, and identify and correct potential hazards. Skilled, semi-skilled or trained personnel may not use this product under their own responsibility unless they have the required specialist knowledge. Otherwise, they may only use the product under the constant supervision of a specialist person.
Compliance with other rules and instructions
Carry out transport and installation/repair activities only in accordance with the valid and applicable safety and accident prevention regulations issued by the trade associations.
The valve contains hydraulic oil. The normal lo­cal environmental protection requirements must therefore be met when handling the product. The particular circumstances of each place of installation mean that instructions must be followed in order to install and use the product safely.
2. Safety
Safety instructions
Please read the operation manual before instal­lation, startup, service, repair or stocking! Paying no attention may result in damaging the valve or incorporated system parts.
Do not disassemble the valve! In case of suspicion for a defect please return it to Parker.
D_FC 5715-686 UK 07.02.2019
10
Parker Hannifin Corporation
Page 11
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
Use of the product
The product must only be used if it is perfect in working order. Problems that may impair safety must be corrected.
This product is a safety component that may only be repaired by the manufacturer if it malfunctions. If the safety components are repaired by the user, the manufacturer's war­ranty is invalidated because the manufac­turer is demonstrably unable to ensure that the product is used as specified.
Limits of use
The product may only be operated within the speci­fied limits of use. The relevant details can be found in „Technical data“.
Ambient conditions must be observed. Un­authorized temperatures, shocks, the effects of aggressive chemicals, radiation, unauthor­ized electromagnetic emissions may result in disruptions and failures. Observe the limits of operation set out in „Technical data”.
Contaminations
Function and service life of the valve are heavily dependent on the purity and quality of the pressure fluid and depend upon the operating conditions of the hydraulic components. Appropriate filters must be used and regular inspections of the medium must be carried out to prevent contamination of the pressure fluid. Permitted level of contamination is set out in the „Technical data“.
Leaking plugs
Leaking plugs can cause a malfunction. That is why the plugs must be checked for leaks at the regular maintenance interval. Leaking plugs may constitute a safety hazard, so the valve must be returned to Parker for repair.
Lightning
If electronic components are exposed to electromagnetic fields as a result of lightning, they must be checked to ensure they are still working perfectly. If there is a malfunction, the product must be returned to Parker.
Temperature
The surface of our product may heat up in use.
The service temperatures may exceed the temperature threshold for burn injury, 70 °C. Above this threshold, even brief contact with the surface may result in a burn. The only way to consistently prevent burn injuries is to use personal protective equipment and to remain safety-conscious at all times.
If integrated electronics are exposed to a temperature above 80 °C, they may malfunc­tion.
Power failure
In a power failure the valve piston returns to the spring centred starting position. You must check whether this creates potential hazards when the system/machine is used.
Be aware of three important sources of con­tamination:
• Contaminations entering during installation
• Contaminations occurring during operation
• Dirt entering from the surroundings
Remaining risks
Allergic reactions
Hydraulic oil can cause allergic reactions on susceptible skin. This can be prevented by taking the precautions that are usual when handling min­eral oil products and by using personal protective equipment.
D_FC 5715-686 UK 07.02.2019
Hydraulic
D*FC/D*1FC valves are tested and approved with an even flow. If the flow becomes asymmetrical, the safety function of the valve may be compro­mised. You should therefore carry out tests before commissioning to verify that the valve is in good working order.
If the valve piston has been under pressure and stationary in the end position for an extended pe­riod, oil particles may cause the piston to seize. For this reason the valve should be actuated regularly.
11
Parker Hannifin Corporation
Page 12
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC

3. Use of the product

Transport

Depending on size, lifting equipment or transport aids are needed. Our product leaves the factory in perfect working order, and appropriate packaging is used to protect it from damage.
The condition of the product on arrival is no longer under our control, so please check for transport damage/defects immediately after arrival. Document the transport damage and immediately notify the carrier, the insurance company and the manufacturer. Do not dis­pose of the packaging unless there is no transport damage and the entire package contents have been removed from the pack­aging. If the product has been damaged during transport, it must be exchanged for a new one.
When transporting the product within your premises, make sure it is kept in a safe position and protected in its original packaging until it is ready to use. Note also the information in sections “Warranty and li­ability”, “Basic information on using the manual”, "Other applicable standards/rules", “Personnel requirements”, “Remaining risks”.
Storage
If the product needs to be temporarily stored, it must be protected from dirt, the weather, and damage. Each valve is tested with hydraulic oil in the factory, so that the internal components are protected from corrosion. However, this protection can only be guaranteed under the following conditions:
Storage time Conditions
12 months
6 months
The product is delivered with adequate corrosion protection, provided our recommendations for the ambient conditions are followed.
Stable air humidity 60 % and stable temperature < 25 °C
Fluctuating air humidity and fluctu­ating temperature < 35 °C
Storage outside or in maritime or tropical climates without appropriate packaging leads to corrosion and may make the product unus­able.
Make sure the product is stored so that no injuries can be caused by tipping or falling. In particular, make sure that the safety rules for high-bay racking are followed.
Commissioning
After installing our product in a system/machine, make sure that the requirements of the Machinery Directive are met if applicable. Access should be provided to the hydraulic diagram, the equipment list and the logic diagram for the system/machine.
The product must be checked for damage and missing parts (e.g. seals) before instal­lation, especially in the area of the sealing surfaces and the safety devices. If the safety devices or sealing surfaces are damaged or are missing individual parts with relevance to the product's function, the product may not be used.
Remove all transport securing devices, protective covers and packaging.
Check for foreign objects in the open hydrau­lic passages. Contaminations may impair operational reliability and shorten the service life.
Make sure that the hydraulic system/machine is unpressurised before the product is in­stalled.
Before commissioning, the specialist person­nel must verify that the entire hydraulic system has been installed correctly. Commissioning must be carried out with care, taking account of all safety regulations.
If necessary, erect warning signs to prevent un­intended operation. Note also the information in sections “Warranty and liability”, “Basic information on using the manual”, "Other applicable standards/ rules", “Personnel requirements”, “Remaining risks”.
Compare valve type (located on the name plate) with part list resp. circuit diagram.
D_FC 5715-686 UK 07.02.2019
12
Parker Hannifin Corporation
Page 13
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
• The valve may be mounted fix or movable in any direction.
• Verify the mounting surface for the valve. Un­evenness of 0.01 mm /100 mm, surface finish of
6.3 µm are tolerable values.
Keep clean valve mounting surface and work environment!
• Remove protection plate from the valve mount­ing surface
• Check the proper position of the valve ports and the O-rings.
Mounting bolts:
D1FC: 4 pcs. M5x30 D3FC: 4 pcs. M6x40 D31FC: 4 pcs. M6x40 D41FC: 2 pcs. M6x55, 4 pcs. M10x60 D91FC: 6 pcs. M12x75, D111FC: 6 pcs. M20x90
Use property class 12.9, ISO 4762
Tighten the bolts crisscross with the following torque values:
D1FC: 7.6 Nm D31FC: 13.2 Nm D3FC: 13.2 Nm D41FC: 13.2/63 Nm
D91FC: 108 Nm D111FC: 517 Nm
Insufficient condition of the valve mounting surface might create malfunction! Incorrect mounting resp. bolt torque may result in abrupt leakage of hydraulic fluid on the valve ports.
Pressure fluids
The following rules apply for the operation with various pressure fluids: The above information serves for orientation and does not substitute user tests among the particular operating conditions. Particularly no liability for media compatibility may be derived out of it.
Mineral oil: usable without restrictions
For operation with the following pressure fluids please consult Parker:
HFA Oil-in-water emulsion
HFB Water-in-oil emulsion
HFC Aqueous solution (glycols)
HFD Unhydrous fluids (Phosphor-Ester)
For detailed information concerning pressure fluids note VDMA-document 24317 as well as DIN 51524 & 51502.
Special gaskets may be available depending on the utilized fluid. In case of insecurity please consult Parker.
Electrical connection
The electrical connection of the valve takes place by one common cable, which is coupled to the integrated electronic driver by a central connector assembly.
The connection Codes 0 and 7 requires a 6 + PE female connector EN 175201-804.
The female connector has to be ordered separately under article nr. 5004072.
A female connector with metal housing is required! Plastic made models may create function problems due to insufficient EMC­characteristics.
The connecting cable has to comply to the follow­ing specification:
Cable type control cable, flexible, 7 conduc­ tors, overall braid shield Cross section min. AWG16/1.0 mm Outer dimension 8...12 mm Cable length max. 50 m
For cable lengths > 50 m consult Parker.
The connection cable is coupled to the female connector by solder joints. Skinning lengths for the connecting cable:
Do not disconnect cable socket under tension!
2
D_FC 5715-686 UK 07.02.2019
13
Parker Hannifin Corporation
Page 14
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
The connection Code 5 requires a 11 + PE female connector EN 175201-804.
The female connector has to be ordered separately under article nr. 5004711.
A female connector with metal housing is required! Plastic made models may create function problems due to insufficient EMC­characteristics.
The connecting cable has to comply to the follow­ing specification:
Cable type control cable, flexible, 8 conductors, overall braid shield Cross section min. AWG16 / 1.0 mm² Outer dimension 12...15 mm Cable length max. 50 m
For cable lengths > 50 m consult Parker.
The connection cable is coupled to the female connector by crimp contacts.
Skinning lengths for the connecting cable:
The backshell nut of the cable gland has to be tighten with a suitable tool. The target value for the tightening torque is 4 Nm. Tighten the cap nut with a torque of approx. 5 Nm after attaching the female connector on the socket outlet.
Incomplete tightening of backshell nut resp. cap nut may result in automatic release of the connection as well as degradation of the water tightness.
Follow the “instructions for use“ for installation
of female connectors made by other kind of brands!
The cable connection to the female connector has to take place by qualified personnel! A short between individual conductors resp. to the connector housing , bad soldering as well as improper shield connection may result in malfunction and breakdown of the valve.
The mounting surface of the valve has to be carefully tied to the earth grounded machine frame. The earth ground wire from the valve connecting cable as well as the cable shield have to be tied to the protective earth termi­nal within the control unit. It is necessary to use a low ohmic potential connection between control unit and machine frame to prevent earth loops (cross section AWG6 > 10 mm²).
For the workmanlike termination of the crimp contacts the tool # 932 507-001 – supplier: Hirschmann – is required.
Do not disconnect cable socket under tension!
The shielding has to be assembled according the outline below:
D_FC 5715-686 UK 07.02.2019
14
Parker Hannifin Corporation
Page 15
Operation Manual
Electrical interfacing
Supply voltage:
The supply voltage for the valve has to cover the range of 18...30 V. The residual ripple may not exceed 5 % eff.
The applied power supply must comply to the relevant regulations (DIN EN 61558) and must carry a CE-mark. The operating voltage for the valve must be free of inductive surges. Do not exceed the max. value of 30 V Non­observance of this rule may result in perma­nent damaging of the valve.
The increased inrush current of the valve
should be considered when selecting the power supply. A stabilized power supply with overcurrent limiting feature should not be used. Due to the inrush current of the valve the current limit circuit may respond prema­turely and create problems during energizing of the supply voltage.
Wiring diagram of supply voltage
Code 0/7 (6 + PE)
Proportional DC Valves
Series D*FC, D*1FC
The operation of the valve is blocked if the
supply voltage polarity is interchanged.
Each valve requires a separate pre-fuse (rat­ing: s. techn. data). Non-observance of this instruction may create irreparable damage of valve resp. incorporated system parts.
Code 5 (11 + PE)
D_FC 5715-686 UK 07.02.2019
15
Parker Hannifin Corporation
Page 16
Operation Manual
Enable input (only for Code 5 / 11+PE and Code 7 / 6 + PE)
A signal voltage enables the actuator drive of the valve. Continuous operation of the valve requires a permanent voltage 5...30 V (i.e. the supply voltage). In case of disabling the signal the valve will reach its hydraulic default (power down) position in no time independently from the command signal value. At the same time the position controller output will be clamped. In case of restarting the enable signal, the valve spool takes its position always out of the power down. Preferable the enable signal should be switched on together with the hydraulic pressure
Wiring diagram of enable input Code 5 (11 + PE)
Proportional DC Valves
Series D*FC, D*1FC
supply. This forces the actuator drive into drop out condition when the hydraulic system is switched off, and it avoids needless heating of the actuator.
The enable function represents no safety arrangement against unwanted valve opera­tion in terms of rules for accident prevention! To block the valve function under all conditions, more advanced steps are necessary, i.e. the installation of additional safety check valves.
Wiring diagram of enable input code 7 (6 + PE)
D_FC 5715-686 UK 07.02.2019
16
Parker Hannifin Corporation
Page 17
Operation Manual
Command signal input
The command signal for the valve will be connected to the pins D and E of the difference signal input of the electronic driver. The spool stroke behaves proportional to the command signal amplitude. Different versions of command signal processing are available, depending on the valve type. These are described below:
For the function description is assumed as signal reference (0V):
Code 0: pin E, Code 7: pin E, Code 5: pin 5
Details are shown from the technical specifi-
cations.
The command input signal needs to be filtered
as well as free of inductive surges and modulations. Due to the sensitivity of the valve a high signal quality is recommended, this will prevent malfunction.
Proportional DC Valves
Series D*FC, D*1FC
Incorrect signal amplitude levels may disturb the functionality and can damage the valve.
The option 4...20 mA uses the “0 mA“ condi-
tion as breakdown-information. This means the presence of an evaluable failure informa­tion if the input signal line is interrupted. In this case the actuator drive will be switched off. The drive will switch on when the input signal reaches a value of 3.8 mA, it switches off when the command falls below 3.6 mA. This determination follows the NAMUR­specification NE43.
NAMUR is an association of users of process
control technology.
D_FC 5715-686 UK 07.02.2019
17
Parker Hannifin Corporation
Page 18
Proportional DC Valves
Operation Manual
Wiring diagram of voltage command input +10...0...-10 V Code 0/7 (6 + PE)
Wiring diagram of current command input 4...12...20 mA Code 0/7 (6 + PE)
Wiring diagram of voltage command input +10...0...-10 V Code 5 (11 + PE)
Series D*FC, D*1FC
Wiring diagram of current command input 4...12...20 mA Code 5 (11 + PE)
D_FC 5715-686 UK 07.02.2019
18
Parker Hannifin Corporation
Page 19
Proportional DC Valves
control system
valve
Operation Manual
Diagnostics output
A diagnostics signal is available. Its voltage repre­sents the operating condition of the valve.
The following information is available:
Wiring diagram of diagnostics output Code 0 (6 + PE)
Reference
diagnosis
diagnostic signal
Wiring diagram of diagnostics output Code 7 (6 + PE)
0 V
Ud
Series D*FC, D*1FC
• position of valve spool (+10...0...-10 V means +100...0...-100 % spool stroke).
spool stroke
0...+100 %
0...-100 %
The output may drive a load of max. 5 mA.
Exceeding of this limit leads to malfunction up to destruction.
diagnostic signalactuator drivefunction
U
on
0
on
on
C-F
0...+10 V U
C-F
0V
U
C-F
0...-10 V
Wiring diagram of diagnostics output Code 5 (11 + PE)
D_FC 5715-686 UK 07.02.2019
19
Parker Hannifin Corporation
Page 20
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
ProPxD parametrizing software
The ProPxD software allows quick and easy setting of the digital valve electronics. Individual parameters as well as complete settings can be viewed, changed and saved via the comfortable user interface. Parameter sets saved in the non-volatile memory can be loaded to other valves of the same type or printed out for documentation purposes.
See www.parker.com/isde section “Support” or directly at www.parker.com/propxd for free software download.
Parametrizing connection
Hardware requirements
• PC with operating system from Windows® XP upwards
• Interface RS232C
• display resolution min. 800 x 600
• connection cable between PC and electronic module
• storage requirement approx. 40 MB
Cable specification
The cable which is required for the connection of the valve electronic to a PC may be ordered un­der code 40982923. The cable has to be inserted between an unused serial port of the PC and the 5pole socket connector of the valve electronic (parametrizing connector).
Attention! The valve electronic provides no USB interface, but can only be parametrized via an RS232 - connection. Therefore the usage of USB standard cables is permitted and may result in damaging of valve resp. PC.
Parametrizing cable
Ordering code: 40982923
Parametering interface
Plug for parametering interface
If your PC has no serial interface according
to RS232 standard, you require in addition an USB-RS232 adapter for connection to the USB interface.
D_FC 5715-686 UK 07.02.2019
The cover plug has to be re-installed after completion of the parametrizing work.
20
Parker Hannifin Corporation
Page 21
Operation Manual
Program installation
Please check before installation if the above hard­ware requirements are met. If your PC has already stored an older version of the “ProPxD” program, it has to be deinstalled by using the Windows® system control feature.
Program installation sequence:
• terminate the execution of other programs
• execute the file “setup.exe”
• follow the instructions on the screen
Answer the question, if an older version should be overwritten, with “ok”. During the installation you may change destination drive resp. installation path, if needed. Please answer “ok” if at the end of the installation the program reports any system informa­tion. After successful installation the desktop display shows the ProPxD icon for starting the program.
Software operating
Brief instruction for first startup:
• Connect the valve electronic to the supply voltage.
• Connect the valve electronic to a PC via the parametrizing cable.
• Start the operating program.
• After displaying the program resp. data base ver­sion a program window opens and the connected valve will be automatically identified (possibly a manual identification via the button “Receive all” is necessary).
• Select the desired version via the menu “Op­tions/Optionen” with the menu item “Language/ Sprache”.
• The valve specific default parameters are already available within the parameter table.
• Individual parameters may be selected via mouse or the arrow buttons at the center of the program screen.
• Parameter changes are possible via mouse or the arrow buttons on the bottom left within the program screen, also the parameter values may be edited via the keyboard.
• Modified parameters will be stored via the “Enter” key or via the button “Update list”.
• Parameters have to be nonvolatile stored on the valve via the button "save parameter".
Proportional DC Valves
Series D*FC, D*1FC
• The chosen parameters may be optionally stored on the PC via the “File”-menu with the menu item “Save as”, data retrieving is always possible via the function “Load file”
Extended functions
The user software is shared into 2 parameter ranges:
• basic mode
• expert mode
For normal startup the basic mode is absolutely sufficient. It permits the setting of all application specific parameters to match the valve function with the task setting. In case of special applications the valve parameters may be adapted via the expert mode. The operating mode may be selected from the “Options”- menu and remains after terminating and re-start of the program.
Changing of expert parameters is only permit­ted for qualified personnel. Incorrect settings may lead to malfunction! In case of param­eter changes shut the drive down!
The expert mode is protected by a pass word request. The name is “parker”. The button “Send parameter” appears in the “Expert”-operating mode. This button transmits only the setting of one single parameter to the connected valve. Thus a quick tuning of single parameters is permitted during the setup.
A horizontal bar graph readout between the
communication buttons shows the data trans­fer state.
Because the ProPxD program has also offline
(i.e. without connection to the valve) function­ality, a manual pre-selection of the parameters is possible. After selection of the valve type via the menu “Options” the parameters may be set and stored for later transmission. Note the design series while selection of the valve!
The “File” menu provides the functions “Printer setup”, “Print preview” and “Print”. The pr int preview includes the option for parameter set storage as text file (format.txt) prior to further processing. The “Options” menu provides also the selection of the RS232C interface port via the menu item “Port”. Via the menu item “Load file” previously stored parameter sets may be loaded.
D_FC 5715-686 UK 07.02.2019
21
Parker Hannifin Corporation
Page 22
Proportional DC Valves
Operation Manual
Individual description of additional expert parameters
Parameter Function Unit
E17 type of command signal device
E19 cable break detection command
E25 MIN operating threshold
P5 Dither amplitude
P6 Dither frequency
P1 Zero adjust
P3 MAX A
P4 MAX B
P7 MIN A
P8 MIN B
S5 ramp accel. A
S6 ramp decel. AB A
S7 ramp accel. B
S8 ramp decel. AB B
J12 Errorhandling
Adjustment of the command signal option. To match the command signal input to the input signal mode.
Adjustment of the operating mode for the command cable break detection. To turn on resp. off of the cable break detection of the command signal at a selected command signal option of
4...20 mA.
Adjustment of the MIN operating threshold. To match the response sensitivity for the MIN-stroke step.
Adjustment of dither amplitude. To reduce the influence of solenoid friction.
Adjustment of dither frequency. To match the dither signal to the valve dynamic.
Adjustment of zero position shifting (offset). To compensate asymmetries.
Adjustment of maximum signal span for positive output signal. To match the command signal span to the valve operating range.
Adjustment of maximum signal span for negative output signal. To match the command signal span to the valve operating range.
Adjustment of stroke step for valve siede A at 0.1% com­mand signal. To compensate for the overlap of the valve spool.
Adjustment fof stroke step for valve siede B at 0.1% com­mand signal. To compensate for the overlap of the valve spool.
Adjustment of ramp rate for increasing of the negative signal polarity. To avoid switching noise.
Adjustment of ramp rate for decreasing of the negative signal polarity. To avoid switching noise.
Adjustment of ramp rate for increasing of the positive signal polarity. To avoid switching noise.
Adjustment of ramp rate for decreasing of the positive signal polarity. To avoid switching noise.
Adjustment of the handling by detecting a fault. For the alignment of the valve reaction at fault diagnosis
Series D*FC, D*1FC
Parameter
Range
1, 2, 3, 5
0, 1
0-200 100
% 0.0 - 15.0
Hz 0 - 300
% -90 - +90 0.0
% 50.0 - 100.0
% 50.0 - 100.0
% 0.0 - 50.0
% 0.0 - 50.0
ms 0 - 32500 0
ms 0 - 32500 0
ms 0 - 32500 0
ms 0 - 32500 0
0, 255, 768,
1023
Default Set-
depending
on valve
depending
on valve
depending
on valve
depending
on valve
depending
on valve
depending
on valve
depending
on valve
depending
on valve
ting
0
D_FC 5715-686 UK 07.02.2019
22
Parker Hannifin Corporation
Page 23
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC

Operation

If any of the safety features of the product are
not operational, the system/machine must be shut down immediately.
Do not carry out any activities that might
jeopardize safety.
Note also the information in sections “Warranty and liability”, “Use of operating instructions)”, “Compli­ance with other rules and instructions”, “Personnel requirements”, “Remaining risks”.
Modification
We define modification as the replacement of a defective valve with a new valve of the same series. In particular, it is not permitted to open the valve.
Make sure that the hydraulic system/machine
is unpressurised before the product is in­stalled/removed.

Service/maintenance

Service work may only be carried out by
qualified personnel. Detailed knowledge of the machine functions concerning switching on and off as well as of the required safety relevant technical tasks is required!
Periodical maintenance is essential for the longevity of the system and guarantees reliability and avail­ability. The following properties of the system has to be checked in continuous short time intervals:
• oil level in the tank
• max. working temperature
• condition of the pressure fluid (visual inspection, color and smell of hydraulic fluid)
• working pressure levels
• gas pre-load pressure on the pressure accu­mulator
• leakage on all system components
• condition of filter elements
• condition of hose lines
• cleanliness of components
After a certain operating duration a change of the hydraulic fluid is required. The frequency of change depends from the following circumstances:
• kind resp. grade of the pressure fluid
• filtering
• operating temperature and environmental conditions
Air bleeding of hydraulic system
During initial startup, after an oil change as well as after the opening of lines or valves the hydraulic system must be air bleeded.
Filter
The function and lifetime of the valve are strongly affected by the cleanliness of the fluid. Purity level class of 18/16/13 acc. ISO 4406 is required.
Flushing
It is recommended to flush the pipelines by short circuiting the pressure and return lines. This prevents the installation dirt from entering the valve.

Decommissioning

Make sure that the hydraulic system/machine is unpressurised before the product is removed. Note also the information in sections “Warranty and liability”, “Use of operating instructions”, “Compli­ance with other rules and instructions”, “Personnel requirements”, “Remaining risks”.

Disposal

At the end of the service life of this product
• all escaping pressure fluids must be removed and disposed of properly
• any significant fluids remaining in the product must be removed and disposed of properly
• all materials must be segregated for recycling when they are removed and taken to a suitable recycling center.
Please segregate the packaging material properly (e.g. paper, plastic). None of the components of the product contain hazardous materials.
The normal local environmental protection
laws must always be met when disposing the product.
Note also the information in sections “Warranty and liability”, “Basic information on using the manual”, "Other applicable standards/rules", “Personnel requirements”, “Remaining risks”.
D_FC 5715-686 UK 07.02.2019
23
Parker Hannifin Corporation
Page 24
Proportional DC Valves
Operation Manual
Trouble shooting
Basis of troubleshooting is always a systematic approach. At first the following questions have to be checked:
• Are there practical experiences with similar failures?
• Have system adjustments been changed?
Afterwards starting of troubleshooting by means of a priority list of the most likely reasons.
For suspect of a sluggish spool the valve may be flushed with clean pressure fluid.
Troubleshooting table
malfunction at hydraulic load runtime
- generally no function
- high frequent oscillation
- low frequent oscillation
- one way operation only
- speed variations at unchanging command
- different speeds depending on travel direction
- speed too low
- drifting without command
- poor dynamic
X hydraulic pump resp. motor defective replace hydraulic pump resp. motor X X X X X X X drive overloaded reduce pressure resp. speed, increase valve size X X X X X X X X valve contaminated clean pressure fluid, filter / flush valve
X X X too low oil level within tank refill pressure fluid
X X X command signal too low increase command signal
X X X X X contacts of central connector contaminated clean contacts / replace plug X feed cable interrupted fix feed cable X X X X X X X wir ing sequence incorrect correct wiring sequence
X pilot pressure too low or failed increase pilot pressure to min. 20 bar
X X X hydraulic fluid too viscous / too cold change fluid grade, provide operational temperature
X X X filter contaminated clean resp. replace filter
X supply voltage carries too much ripple reduce ripple
X command signal carries too much ripple reduce ripple
X X center position adjustment incorrect check center position adjustment
X X feed cable without shielding change cable grade
X X X pilot pressure too low increase pilot pressure to min. 20 bar
possible reasons for malfunction corrective actions
X pilot pressure too low increase pilot pressure to min. 50 bar
Series D*FC, D*1FC
Troubleshooting in a hydraulic system requires in either case a systematic approach. The work may exclusively be performed by qualified personnel, as it requires detailed knowledge about function and construction of the system. Reversals or disassemblies may not be taken imprudently! Prior to the works it has to be clarified, if the system has been operated properly until the failure oc­cured.

4. Product information

Other applicable standards / rules
• ISO 4406:1999-12 Hydraulic fluid power - Fluids
- Method for coding the level of contamination by solid particles
• ISO 4401:2005-07 Hydraulic valves; mounting surfaces and connecting plates
• DIN EN 60204-1; VDE 0113-1:2007-06 Safety of machinery – Electrical equipment of machines – Part 1: General requirements
• DIN EN 60529; VDE 0470-1:2000-09 Degrees of protection provided by enclosures (IP code)
D_FC 5715-686 UK 07.02.2019
• DIN EN 61000-4-2/3/4/6/8 Electromagnetic compatibility
• DIN 51524-1:2006-04 Pressure fluids - HLP hydraulic oils - Part 1: Minimum requirements
• DIN 51525-2:2006-04 Pressure fluids - HLP hydraulic oils - Part 2: Minimum requirements
• German Occupation Safety Ordinance (Be­triebssicherheitsverordnung)
• German Labour Protection Act (Arbeitsschutz­gesetz)
24
Parker Hannifin Corporation
Page 25
Operation Manual

Accessories / spare parts

Proportional DC Valves
Series D*FC, D*1FC
Accessories
The following accessories are available for the valve series D*FC/D*1FC:
D1FC: Bolt kit ordering code BK375 Code 0/1/3/7: female conn. 6+PE ord. code 5004072 Code 5: female conn. 11+PE ord. code 5004711
D3FC, D31FC: Bolt kit ordering code BK385 Code 0/1/3/7: female conn. 6+PE ord. code 5004072 Code 5: female conn. 11+PE ord. code 5004711
D41FC: Bolt kit ordering code BK320 Code 0/1/3/7: female conn. 6+PE ord. code 5004072 Code 5: female conn. 11+PE ord. code 5004711
D91FC: Bolt kit ordering code BK360 Code 0/1/3/7: female conn. 6+PE ord. code 5004072 Code 5: female conn. 11+PE ord. code 5004711
D111FC: Bolt kit ordering code BK386 Code 0/1/3/7: female conn. 6+PE ord. code 5004072 Code 5: female conn. 11+PE ord. code 5004711
Spare parts
The following spare parts are available:
D1FC: Seal kit NBR ordering code SK-D1FC Seal kit FPM ordering code SK-D1FC-V
D3FC: Seal kit NBR ordering code SK-D3FC Seal kit FPM ordering code SK-D3FC-V
D31FC: Seal kit NBR ordering code SK-D31FC Seal kit FPM ordering code SK-D31FC-V
D41FC: Seal kit NBR ordering code SK-D41FC Seal kit FPM ordering code SK-D41FC-V
D91FC: Seal kit NBR ordering code SK-D91FC Seal kit FPM ordering code SK-D91FC-V
D111FC: Seal kit NBR ordering code SK-D111FC Seal kit FPM ordering code SK-D111FC-V
Please direct technical product enquiries to:
Parker Hannifin Manufacturing Germany GmbH & Co. KG
Industrial Systems Division Europe Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+49) 181 99 44 43 0 E-mail: valvesisde@parker.com
Hotline in Europe
Phone: 00800-2727-5374
D_FC 5715-686 UK 07.02.2019