FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED
HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY
DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and
authorized distributors provide product or system options for further investigation by users having
technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection
of the system and components and assuring that all performance, endurance, maintenance,
safety and warning requirements of the application are met. The user must analyze all aspects
of the application, follow applicable industry standards, and follow the information concerning
the product in the current product catalog and in any other materials provided from Parker or its
subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or
system options based upon data or specifications provided by the user, the user is responsible for
determining that such data and specifications are suitable and sufficient for all applications and
reasonably foreseeable uses of the components or systems.
D_FC 5715-686 UK 07.02.2019
2
Parker Hannifin Corporation
Page 3
Proportional DC Valves
Operation Manual
ContentPage
1.Introduction4
Ordering code D*FC4
Ordering code D*1FC5
Name plate example6
Characteristics of valve driver6
Block diagram of integral electronics7
Technical data8
Signal flow diagram9
Scope of supply
Important information10
Information on the process of technical changes10
Information on warranty and liability10
CE mark10
Personnel requirements10
Compliance with other rules and instructions10
2.Safety10
Safety instructions10
Use of the product11
Limits of use11
Contaminations11
Remaining risks11
3.Use of the product12
Transport12
Storage12
Commissioning12
Pressure fluids13
Electrical connection13
Electrical interfacing15
ProPxD parametrizing software20
Operation23
Service/maintenance23
Air bleeding of hydraulic system23
Filter23
Flushing23
Decommissioning23
Disposal23
Trouble shooting23
4.Product information24
Other applicable standards/rules24
Accessories / spare parts25
Series D*FC, D*1FC
10
D_FC 5715-686 UK 07.02.2019
3
Parker Hannifin Corporation
Page 4
Proportional DC Valves
Operation Manual
1. Introduction
D*FC
Main connector
(always on A-side
of main stage)
Air bleeding
Manual override
Ordering code D*FC
Series D*FC, D*1FC
DFC93
Parametrizing
connection
DC
valve
Nominal
size
Proportional
control
High
dynamics
Spool
type
(see
catalogue)
Spool
position
Drain port Y
plugged
1)
4)
CodeNominal size
1NG06 / CETOP 03
3NG10 / CETOP 05
Spool position on
Code
A
B
C
1)
On power down the spool moves in a defined position.
B – T with pressure drops above 120 bar or contamination in the hydraulic fluid.
2)
Approx. 10 % opening, only zero lapped spools and underlap spools.
3)
Only for overlapped spools.
4)
Needs to be removed at tank pressure >35 bar.
5)
Please order connector separately.
D_FC 5715-686 UK 07.02.2019
power down
2)
2)
3)
This cannot be guaranteed in case of single flow path on the control edge A – T resp.
4
Command
signal
Spool/
body
design
SealDesign
Electrical
options
series
(not required
for ordering)
Code Electronic options
06 + PE
511 + PE
76 + PE with enable
CodeSignalFunction
B0...±10 V
0...±20 mA0...+20 mA
E
K0...±10 V
S4...20 mA
0...+10 V
P -> A
P -> A
0...+10 V
P -> B
12...20 mA
P -> A
CodeSeal
NNBR
VFPM
Parker Hannifin Corporation
5)
Page 5
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
D*1FC
Parametrizing
connection
Ordering code D*1FC
D1FCC
Direct.
control
valve
Nominal
size
NG06
pilot
Proportional
control
Integrated
electronics
with position
feedback
Function
(see catalogue)
Flow
(see catalogue)
Spool position
on power down
A
TAPB
connection
(see catalogue)
(see catalogue)
Main connector
(always on B-side of
main stage)
B
Pilot
Command
signal
SealDesign
Electrical
options
Manual override
Valve
options
2)
series
(not required
for ordering)
CodeNominal size
3NG10 / CETOP 05
4NG16 / CETOP 07
9 1)NG25 / CETOP 08
11NG32 / CETOP 10
CodeSeal
NNBR
VFPM
CodeSignalFunction
B0...±10 V
0...±20 mA0...+20 mA
E
K0...±10 V
S4...20 mA
D_FC 5715-686 UK 07.02.2019
0...+10 V
P -> B
P -> B
0...+10 V
P -> A
12...20 mA
P -> A
CodeValve options
Standard für
0
spool type B, E, R
2) 3)
8
Monitor switch
Hybrid valve 24 V
L
normaly closed for
spool type Z
Code Electronic options
06 + PE
511 + PE
76 + PE with enable
1)
With enlarged connections Ø 32 mm.
2)
Not for D111FCZ*.
3)
Monitor switch for hybrid valves: code 8 includes options of code L
(24 V normally closed).
5
Parker Hannifin Corporation
Page 6
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
Name plate example
nominal pressure
hydr. spool symbol
order code
Parker D*FC and D*1FC proportional directional
control valves have an integral electronics. Different flow sizes as well as command signal options
are available to achieve an optimal adaption for
different applications.
Characteristics of valve driver
The described integral electronic driver combines
all necessary functions for the optimal operation of
the valve. The most important features are:
• digital circuit design
• high dynamic constant current solenoid control
• differential input stage with various command
signal options
• four quadrant ramp function
• MIN adjustment for deadband compensation
• MAX adjustment to match the command signal
span to the valve operating range
D_FC 5715-686 UK 07.02.2019
6
Parker Hannifin Corporation
Page 7
Operation Manual
Block diagram of integral electronics
D*FC, Code 0 (6+PE)
Proportional DC Valves
Series D*FC, D*1FC
D*1FC, Code 0 (6+PE)
D*FC, Code 5 (11+PE)
D*FC, Code 7 (6+PE with enable)D*1FC, Code 7 (6+PE with enable)
Operating pressure[bar] D*FC: Ports P, A, B 350, port T max. 35; 210 (external drain);
FluidHydraulic oil according to DIN 51524 ... 535, other on request
Fluid temperature[°C] -20...+60 (NBR: -25...+60)
Viscosity permitted
recommended
FiltrationISO 4406; 18/16/13
Electrical
Duty ratio[%] 100
Protection classIP65 acc. EN 60529 (with correctly mounted plug-in connector)
Supply voltage Us[VDC] 18...30, electric shut-off at < 17, ripple < 5 % eff., surge free
Current consumption max.[A] 2.0 (D1FC, D*1FC), 3.5 (D3FC)
Pre-fusing[A] 2.5 (D1FC, D*1FC), 4.0 (D3FC)
Command signal Uc
options
Ic
Differential input voltage
max.
Adjustment ranges Min[%] 0...50
Max[%] 50...100
Ramp[s] 0...32.5
InterfaceRS232C, parametrizing connection 5pole
Enable signal (code 1/5/7)[V] 5...30
Diagnostic signal[V] +10...0...-10 / +12.5 error detection, rated max. 5 mA
EMCEN 61000-6-2, EN 61000-6-4
Central connectionCode 0//7: 6+PE acc. EN 175201-804
Code 0/7: 30 for terminal D and E against PE (terminal G)
[V]
11 for terminal D and E against 0 V (terminal B)
[V]
Code 5: 30 for terminal 4 and 5 against PE (terminal W)
[V]
11 for terminal 4 and 5 against 0 V (terminal 2)
Code 5: 11+PE acc. EN 175201-804
Code 0/7: 7 x 1.0 (AWG16) overall braid shield
[mm²]
Code 5: 8 x 1.0 (AWG20) overall braid shield
Series D*FC, D*1FC
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
1)
If valves with onboard electronics are used in safety-related parts of control systems, in case the safety function is requested, the
valve electronics voltage supply is to be switched off by a suitable switching element with sufficient reliability.
D_FC 5715-686 UK 07.02.2019
8
Parker Hannifin Corporation
Page 9
Operation Manual
Command
Ramps
eedbac
positio
eedbac
current
eedbac
current
Signal flow diagram
Dither
Proportional DC Valves
Series D*FC, D*1FC
Solenoid A
Solenoid B
PI
P6
P5
Freq.
Ampl.
PID
P7
Min
Min A
A-
S6
S5
A+
D_FC 5715-686 UK 07.02.2019
S7
B+
E17
Option
Command
P8
S8
E19
Min B
B-
Break
P4
P3
P1
Max
Max B
Max A
Zero
k
F
9
k
n
F
k
A
B
F
Enable
Parker Hannifin Corporation
Basic Mode
Expert Mode
Page 10
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
Scope of supply
Please check immediately after receiving the valve,
if the content is matching with the specified scope
of supply. The delivery includes:
• valve
• operation manual
The central connector assembly has to be ordered
separately and is not included in the delivery.
Please check the delivery immediately after
receiving the shipment for apparent damages due to shipping. Report shipment
losses at once to the carrier, the insurance
company and the supplier!
Intended usage
This operation manual is valid for proportional directional control valves D*FC/D*1FC series. Any different or beyond it usage is deemed to be as not
intended. The manufacturer is not liable for warranty
claims resulting from this.
Information on the process of technical changes
We reserve the right to make technical changes
as a result of further development of the product
described in these operating instructions. Figures
and drawings in these instructions are simplified
depictions. As a result of developments, improvements and changes to the product, it is possible that
the figures are not fully consistent with the valve in
operation. The technical details and dimensions are
non-binding. They may not form the basis of any
claims. Copyright reserved.
Information on warranty and liability
The manufacturer does not assume liability for
damage due to the following failures:
• incorrect mounting / installation
• improper handling
• lack of maintenance
• operation outside the specification
CE mark
The CE mark appears on the main nameplate. If the
product is installed as part of a larger machine, this
larger machine is in turn subject to EU directives
and must therefore obtain a general CE mark for the
machine as a whole. The machine must not enter
circulation in the EU until this is done. The legal
requirements corresponding to the CE mark can be
found in section "Other applicable standards / rules".
Personnel requirements
The product may only be used, installed, removed,
operated and maintained by specialist personnel.
For the purposes of these instructions, a specialist
is defined as someone who, on the basis of their
education, expertise and professional experience,
is able to correctly evaluate and carry out the tasks
and duties assigned to him/her, and identify and
correct potential hazards. Skilled, semi-skilled or
trained personnel may not use this product under
their own responsibility unless they have the required
specialist knowledge. Otherwise, they may only
use the product under the constant supervision of
a specialist person.
Compliance with other rules and instructions
Carry out transport and installation/repair activities
only in accordance with the valid and applicable
safety and accident prevention regulations issued
by the trade associations.
The valve contains hydraulic oil. The normal local environmental protection requirements must
therefore be met when handling the product. The
particular circumstances of each place of installation
mean that instructions must be followed in order to
install and use the product safely.
2. Safety
Safety instructions
Please read the operation manual before installation, startup, service, repair or stocking! Paying
no attention may result in damaging the valve or
incorporated system parts.
Do not disassemble the valve! In case of
suspicion for a defect please return it to
Parker.
D_FC 5715-686 UK 07.02.2019
10
Parker Hannifin Corporation
Page 11
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
Use of the product
The product must only be used if it is perfect in
working order. Problems that may impair safety
must be corrected.
This product is a safety component that may
only be repaired by the manufacturer if it
malfunctions. If the safety components are
repaired by the user, the manufacturer's warranty is invalidated because the manufacturer is demonstrably unable to ensure that
the product is used as specified.
Limits of use
The product may only be operated within the specified limits of use. The relevant details can be found
in „Technical data“.
Ambient conditions must be observed. Unauthorized temperatures, shocks, the effects
of aggressive chemicals, radiation, unauthorized electromagnetic emissions may result in
disruptions and failures. Observe the limits
of operation set out in „Technical data”.
Contaminations
Function and service life of the valve are heavily
dependent on the purity and quality of the pressure
fluid and depend upon the operating conditions of
the hydraulic components. Appropriate filters must
be used and regular inspections of the medium
must be carried out to prevent contamination of the
pressure fluid. Permitted level of contamination is
set out in the „Technical data“.
Leaking plugs
Leaking plugs can cause a malfunction. That
is why the plugs must be checked for leaks
at the regular maintenance interval. Leaking
plugs may constitute a safety hazard, so the
valve must be returned to Parker for repair.
Lightning
If electronic components are exposed to
electromagnetic fields as a result of lightning,
they must be checked to ensure they are still
working perfectly. If there is a malfunction,
the product must be returned to Parker.
Temperature
The surface of our product may heat up in use.
The service temperatures may exceed the
temperature threshold for burn injury, 70 °C.
Above this threshold, even brief contact with
the surface may result in a burn. The only way
to consistently prevent burn injuries is to use
personal protective equipment and to remain
safety-conscious at all times.
If integrated electronics are exposed to a
temperature above 80 °C, they may malfunction.
Power failure
In a power failure the valve piston returns to
the spring centred starting position. You must
check whether this creates potential hazards
when the system/machine is used.
Be aware of three important sources of contamination:
• Contaminations entering during installation
• Contaminations occurring during operation
• Dirt entering from the surroundings
Remaining risks
Allergic reactions
Hydraulic oil can cause allergic reactions on
susceptible skin. This can be prevented by taking
the precautions that are usual when handling mineral oil products and by using personal protective
equipment.
D_FC 5715-686 UK 07.02.2019
Hydraulic
D*FC/D*1FC valves are tested and approved with
an even flow. If the flow becomes asymmetrical,
the safety function of the valve may be compromised. You should therefore carry out tests before
commissioning to verify that the valve is in good
working order.
If the valve piston has been under pressure and
stationary in the end position for an extended period, oil particles may cause the piston to seize. For
this reason the valve should be actuated regularly.
11
Parker Hannifin Corporation
Page 12
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
3. Use of the product
Transport
Depending on size, lifting equipment or transport
aids are needed. Our product leaves the factory in
perfect working order, and appropriate packaging
is used to protect it from damage.
The condition of the product on arrival is no
longer under our control, so please check for
transport damage/defects immediately after
arrival. Document the transport damage and
immediately notify the carrier, the insurance
company and the manufacturer. Do not dispose of the packaging unless there is no
transport damage and the entire package
contents have been removed from the packaging. If the product has been damaged
during transport, it must be exchanged for a
new one.
When transporting the product within your premises,
make sure it is kept in a safe position and protected
in its original packaging until it is ready to use. Note
also the information in sections “Warranty and liability”, “Basic information on using the manual”,
"Other applicable standards/rules", “Personnel
requirements”, “Remaining risks”.
Storage
If the product needs to be temporarily stored, it must
be protected from dirt, the weather, and damage.
Each valve is tested with hydraulic oil in the factory,
so that the internal components are protected from
corrosion. However, this protection can only be
guaranteed under the following conditions:
Storage time Conditions
12 months
6 months
The product is delivered with adequate corrosion
protection, provided our recommendations for the
ambient conditions are followed.
Stable air humidity 60 % and
stable temperature < 25 °C
Fluctuating air humidity and fluctuating temperature < 35 °C
Storage outside or in maritime or tropical
climates without appropriate packaging leads
to corrosion and may make the product unusable.
Make sure the product is stored so that no
injuries can be caused by tipping or falling. In
particular, make sure that the safety rules for
high-bay racking are followed.
Commissioning
After installing our product in a system/machine,
make sure that the requirements of the Machinery
Directive are met if applicable. Access should be
provided to the hydraulic diagram, the equipment
list and the logic diagram for the system/machine.
The product must be checked for damage
and missing parts (e.g. seals) before installation, especially in the area of the sealing
surfaces and the safety devices. If the safety
devices or sealing surfaces are damaged or
are missing individual parts with relevance to
the product's function, the product may not
be used.
Remove all transport securing devices, protective
covers and packaging.
Check for foreign objects in the open hydraulic passages. Contaminations may impair
operational reliability and shorten the service
life.
Make sure that the hydraulic system/machine
is unpressurised before the product is installed.
Before commissioning, the specialist personnel must verify that the entire hydraulic system
has been installed correctly. Commissioning
must be carried out with care, taking account
of all safety regulations.
If necessary, erect warning signs to prevent unintended operation. Note also the information in
sections “Warranty and liability”, “Basic information
on using the manual”, "Other applicable standards/
rules", “Personnel requirements”, “Remaining risks”.
Compare valve type (located on the name plate)
with part list resp. circuit diagram.
D_FC 5715-686 UK 07.02.2019
12
Parker Hannifin Corporation
Page 13
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
• The valve may be mounted fix or movable in
any direction.
• Verify the mounting surface for the valve. Unevenness of 0.01 mm /100 mm, surface finish of
6.3 µm are tolerable values.
Keep clean valve mounting surface and work
environment!
• Remove protection plate from the valve mounting surface
• Check the proper position of the valve ports and
the O-rings.
Insufficient condition of the valve mounting
surface might create malfunction! Incorrect
mounting resp. bolt torque may result in abrupt
leakage of hydraulic fluid on the valve ports.
Pressure fluids
The following rules apply for the operation with
various pressure fluids: The above information
serves for orientation and does not substitute user
tests among the particular operating conditions.
Particularly no liability for media compatibility may
be derived out of it.
Mineral oil: usable without restrictions
For operation with the following pressure fluids
please consult Parker:
HFAOil-in-water emulsion
HFBWater-in-oil emulsion
HFCAqueous solution (glycols)
HFDUnhydrous fluids (Phosphor-Ester)
For detailed information concerning pressure fluids
note VDMA-document 24317 as well as DIN 51524
& 51502.
Special gaskets may be available depending
on the utilized fluid. In case of insecurity please
consult Parker.
Electrical connection
The electrical connection of the valve takes place
by one common cable, which is coupled to the
integrated electronic driver by a central connector
assembly.
The connection Codes 0 and 7 requires a 6 + PE
female connector EN 175201-804.
The female connector has to be ordered
separately under article nr. 5004072.
A female connector with metal housing is
required! Plastic made models may create
function problems due to insufficient EMCcharacteristics.
The connecting cable has to comply to the following specification:
Cable type control cable, flexible, 7 conduc tors, overall braid shield
Cross section min. AWG16/1.0 mm
Outer dimension 8...12 mm
Cable length max. 50 m
For cable lengths > 50 m consult Parker.
The connection cable is coupled to the female
connector by solder joints.
Skinning lengths for the connecting cable:
Do not disconnect cable socket under tension!
2
D_FC 5715-686 UK 07.02.2019
13
Parker Hannifin Corporation
Page 14
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
The connection Code 5 requires a 11 + PE female
connector EN 175201-804.
The female connector has to be ordered
separately under article nr. 5004711.
A female connector with metal housing is
required! Plastic made models may create
function problems due to insufficient EMCcharacteristics.
The connecting cable has to comply to the following specification:
Cable type control cable, flexible,
8 conductors, overall braid
shield
Cross section min. AWG16 / 1.0 mm²
Outer dimension 12...15 mm
Cable length max. 50 m
For cable lengths > 50 m consult Parker.
The connection cable is coupled to the female
connector by crimp contacts.
Skinning lengths for the connecting cable:
The backshell nut of the cable gland has to be
tighten with a suitable tool. The target value for the
tightening torque is 4 Nm. Tighten the cap nut with
a torque of approx. 5 Nm after attaching the female
connector on the socket outlet.
Incomplete tightening of backshell nut resp.
cap nut may result in automatic release of the
connection as well as degradation of the
water tightness.
Follow the “instructions for use“ for installation
of female connectors made by other kind of
brands!
The cable connection to the female connector
has to take place by qualified personnel! A
short between individual conductors resp. to
the connector housing , bad soldering as well
as improper shield connection may result in
malfunction and breakdown of the valve.
The mounting surface of the valve has to be
carefully tied to the earth grounded machine
frame. The earth ground wire from the valve
connecting cable as well as the cable shield
have to be tied to the protective earth terminal within the control unit. It is necessary to
use a low ohmic potential connection between
control unit and machine frame to prevent
earth loops (cross section AWG6 > 10 mm²).
For the workmanlike termination of the crimp
contacts the tool # 932 507-001 – supplier:
Hirschmann – is required.
Do not disconnect cable socket under tension!
The shielding has to be assembled according the
outline below:
D_FC 5715-686 UK 07.02.2019
14
Parker Hannifin Corporation
Page 15
Operation Manual
Electrical interfacing
Supply voltage:
The supply voltage for the valve has to cover the
range of 18...30 V. The residual ripple may not
exceed 5 % eff.
The applied power supply must comply to the
relevant regulations (DIN EN 61558) and must
carry a CE-mark. The operating voltage for
the valve must be free of inductive surges.
Do not exceed the max. value of 30 V Nonobservance of this rule may result in permanent damaging of the valve.
The increased inrush current of the valve
should be considered when selecting the
power supply. A stabilized power supply with
overcurrent limiting feature should not be
used. Due to the inrush current of the valve
the current limit circuit may respond prematurely and create problems during energizing
of the supply voltage.
Wiring diagram of supply voltage
Code 0/7 (6 + PE)
Proportional DC Valves
Series D*FC, D*1FC
The operation of the valve is blocked if the
supply voltage polarity is interchanged.
Each valve requires a separate pre-fuse (rating: s. techn. data). Non-observance of this
instruction may create irreparable damage of
valve resp. incorporated system parts.
Code 5 (11 + PE)
D_FC 5715-686 UK 07.02.2019
15
Parker Hannifin Corporation
Page 16
Operation Manual
Enable input (only for Code 5 / 11+PE and
Code 7 / 6 + PE)
A signal voltage enables the actuator drive of the
valve. Continuous operation of the valve requires a
permanent voltage 5...30 V (i.e. the supply voltage).
In case of disabling the signal the valve will reach its
hydraulic default (power down) position in no time
independently from the command signal value. At
the same time the position controller output will be
clamped. In case of restarting the enable signal,
the valve spool takes its position always out of the
power down. Preferable the enable signal should
be switched on together with the hydraulic pressure
Wiring diagram of enable input Code 5 (11 + PE)
Proportional DC Valves
Series D*FC, D*1FC
supply. This forces the actuator drive into drop out
condition when the hydraulic system is switched off,
and it avoids needless heating of the actuator.
The enable function represents no safety
arrangement against unwanted valve operation in terms of rules for accident prevention!
To block the valve function under all conditions,
more advanced steps are necessary, i.e.
the installation of additional safety check
valves.
Wiring diagram of enable input code 7 (6 + PE)
D_FC 5715-686 UK 07.02.2019
16
Parker Hannifin Corporation
Page 17
Operation Manual
Command signal input
The command signal for the valve will be connected
to the pins D and E of the difference signal input
of the electronic driver. The spool stroke behaves
proportional to the command signal amplitude.
Different versions of command signal processing
are available, depending on the valve type. These
are described below:
For the function description is assumed as signal
reference (0V):
Code 0: pin E, Code 7: pin E, Code 5: pin 5
Details are shown from the technical specifi-
cations.
The command input signal needs to be filtered
as well as free of inductive surges and
modulations. Due to the sensitivity of the valve
a high signal quality is recommended, this
will prevent malfunction.
Proportional DC Valves
Series D*FC, D*1FC
Incorrect signal amplitude levels may disturb
the functionality and can damage the valve.
The option 4...20 mA uses the “0 mA“ condi-
tion as breakdown-information. This means
the presence of an evaluable failure information if the input signal line is interrupted. In
this case the actuator drive will be switched
off. The drive will switch on when the input
signal reaches a value of 3.8 mA, it switches
off when the command falls below 3.6 mA.
This determination follows the NAMURspecification NE43.
NAMUR is an association of users of process
control technology.
D_FC 5715-686 UK 07.02.2019
17
Parker Hannifin Corporation
Page 18
Proportional DC Valves
Operation Manual
Wiring diagram of voltage command input +10...0...-10 V Code 0/7 (6 + PE)
Wiring diagram of current command input 4...12...20 mA Code 0/7 (6 + PE)
Wiring diagram of voltage command input +10...0...-10 V Code 5 (11 + PE)
Series D*FC, D*1FC
Wiring diagram of current command input 4...12...20 mA Code 5 (11 + PE)
D_FC 5715-686 UK 07.02.2019
18
Parker Hannifin Corporation
Page 19
Proportional DC Valves
control system
valve
Operation Manual
Diagnostics output
A diagnostics signal is available. Its voltage represents the operating condition of the valve.
The following information is available:
Wiring diagram of diagnostics output Code 0 (6 + PE)
Reference
diagnosis
diagnostic
signal
Wiring diagram of diagnostics output Code 7 (6 + PE)
0 V
Ud
Series D*FC, D*1FC
• position of valve spool (+10...0...-10 V means
+100...0...-100 % spool stroke).
spool stroke
0...+100 %
0...-100 %
The output may drive a load of max. 5 mA.
Exceeding of this limit leads to malfunction
up to destruction.
diagnostic signalactuator drivefunction
U
on
0
on
on
C-F
0...+10 V
U
C-F
0V
U
C-F
0...-10 V
Wiring diagram of diagnostics output Code 5 (11 + PE)
D_FC 5715-686 UK 07.02.2019
19
Parker Hannifin Corporation
Page 20
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
ProPxD parametrizing software
The ProPxD software allows quick and easy setting
of the digital valve electronics. Individual parameters
as well as complete settings can be viewed, changed
and saved via the comfortable user interface.
Parameter sets saved in the non-volatile memory
can be loaded to other valves of the same type or
printed out for documentation purposes.
See www.parker.com/isde section “Support” or
directly at www.parker.com/propxd for free software
download.
Parametrizing connection
Hardware requirements
• PC with operating system from Windows® XP
upwards
• Interface RS232C
• display resolution min. 800 x 600
• connection cable between PC and electronic
module
• storage requirement approx. 40 MB
Cable specification
The cable which is required for the connection of
the valve electronic to a PC may be ordered under code 40982923. The cable has to be inserted
between an unused serial port of the PC and the
5pole socket connector of the valve electronic
(parametrizing connector).
Attention! The valve electronic provides no
USB interface, but can only be parametrized
via an RS232 - connection. Therefore the
usage of USB standard cables is permitted
and may result in damaging of valve resp. PC.
Parametrizing cable
Ordering code: 40982923
Parametering interface
Plug for
parametering interface
If your PC has no serial interface according
to RS232 standard, you require in addition
an USB-RS232 adapter for connection to the
USB interface.
D_FC 5715-686 UK 07.02.2019
The cover plug has to be re-installed after
completion of the parametrizing work.
20
Parker Hannifin Corporation
Page 21
Operation Manual
Program installation
Please check before installation if the above hardware requirements are met. If your PC has already
stored an older version of the “ProPxD” program,
it has to be deinstalled by using the Windows®
system control feature.
Program installation sequence:
• terminate the execution of other programs
• execute the file “setup.exe”
• follow the instructions on the screen
Answer the question, if an older version should be
overwritten, with “ok”. During the installation you
may change destination drive resp. installation path,
if needed. Please answer “ok” if at the end of the
installation the program reports any system information. After successful installation the desktop display
shows the ProPxD icon for starting the program.
Software operating
Brief instruction for first startup:
• Connect the valve electronic to the supply voltage.
• Connect the valve electronic to a PC via the
parametrizing cable.
• Start the operating program.
• After displaying the program resp. data base version a program window opens and the connected
valve will be automatically identified (possibly a
manual identification via the button “Receive all”
is necessary).
• Select the desired version via the menu “Options/Optionen” with the menu item “Language/
Sprache”.
• The valve specific default parameters are already
available within the parameter table.
• Individual parameters may be selected via
mouse or the arrow buttons at the center of the
program screen.
• Parameter changes are possible via mouse or
the arrow buttons on the bottom left within the
program screen, also the parameter values may
be edited via the keyboard.
• Modified parameters will be stored via the “Enter”
key or via the button “Update list”.
• Parameters have to be nonvolatile stored on the
valve via the button "save parameter".
Proportional DC Valves
Series D*FC, D*1FC
• The chosen parameters may be optionally stored
on the PC via the “File”-menu with the menu item
“Save as”, data retrieving is always possible via
the function “Load file”
Extended functions
The user software is shared into 2 parameter ranges:
• basic mode
• expert mode
For normal startup the basic mode is absolutely
sufficient. It permits the setting of all application
specific parameters to match the valve function with
the task setting. In case of special applications the
valve parameters may be adapted via the expert
mode. The operating mode may be selected from
the “Options”- menu and remains after terminating
and re-start of the program.
Changing of expert parameters is only permitted for qualified personnel. Incorrect settings
may lead to malfunction! In case of parameter changes shut the drive down!
The expert mode is protected by a pass word
request. The name is “parker”. The button “Send
parameter” appears in the “Expert”-operating mode.
This button transmits only the setting of one single
parameter to the connected valve. Thus a quick
tuning of single parameters is permitted during
the setup.
A horizontal bar graph readout between the
communication buttons shows the data transfer state.
Because the ProPxD program has also offline
(i.e. without connection to the valve) functionality, a manual pre-selection of the parameters
is possible. After selection of the valve type
via the menu “Options” the parameters may
be set and stored for later transmission. Note
the design series while selection of the valve!
The “File” menu provides the functions “Printer
setup”, “Print preview” and “Print”. The pr int preview
includes the option for parameter set storage as
text file (format.txt) prior to further processing. The
“Options” menu provides also the selection of the
RS232C interface port via the menu item “Port”.
Via the menu item “Load file” previously stored
parameter sets may be loaded.
D_FC 5715-686 UK 07.02.2019
21
Parker Hannifin Corporation
Page 22
Proportional DC Valves
Operation Manual
Individual description of additional expert parameters
ParameterFunctionUnit
E17
type of command
signal device
E19
cable break
detection command
E25
MIN operating
threshold
P5
Dither amplitude
P6
Dither frequency
P1
Zero adjust
P3
MAX A
P4
MAX B
P7
MIN A
P8
MIN B
S5
ramp accel. A
S6
ramp decel. AB A
S7
ramp accel. B
S8
ramp decel. AB B
J12
Errorhandling
Adjustment of the command signal option.
To match the command signal input to the input signal
mode.
Adjustment of the operating mode for the command cable
break detection.
To turn on resp. off of the cable break detection of the
command signal at a selected command signal option of
4...20 mA.
Adjustment of the MIN operating threshold.
To match the response sensitivity for the MIN-stroke step.
Adjustment of dither amplitude.
To reduce the influence of solenoid friction.
Adjustment of dither frequency.
To match the dither signal to the valve dynamic.
Adjustment of zero position shifting (offset).
To compensate asymmetries.
Adjustment of maximum signal span for positive output
signal.
To match the command signal span to the valve operating
range.
Adjustment of maximum signal span for negative output
signal.
To match the command signal span to the valve operating
range.
Adjustment of stroke step for valve siede A at 0.1% command signal.
To compensate for the overlap of the valve spool.
Adjustment fof stroke step for valve siede B at 0.1% command signal.
To compensate for the overlap of the valve spool.
Adjustment of ramp rate for increasing of the negative
signal polarity.
To avoid switching noise.
Adjustment of ramp rate for decreasing of the negative
signal polarity.
To avoid switching noise.
Adjustment of ramp rate for increasing of the positive
signal polarity.
To avoid switching noise.
Adjustment of ramp rate for decreasing of the positive signal
polarity.
To avoid switching noise.
Adjustment of the handling by detecting a fault.
For the alignment of the valve reaction at fault diagnosis
Series D*FC, D*1FC
Parameter
Range
–1, 2, 3, 5
–0, 1
–0-200100
%0.0 - 15.0
Hz0 - 300
%-90 - +900.0
% 50.0 - 100.0
% 50.0 - 100.0
%0.0 - 50.0
%0.0 - 50.0
ms0 - 325000
ms0 - 325000
ms0 - 325000
ms0 - 325000
0, 255, 768,
–
1023
Default Set-
depending
on valve
depending
on valve
depending
on valve
depending
on valve
depending
on valve
depending
on valve
depending
on valve
depending
on valve
ting
0
D_FC 5715-686 UK 07.02.2019
22
Parker Hannifin Corporation
Page 23
Operation Manual
Proportional DC Valves
Series D*FC, D*1FC
Operation
If any of the safety features of the product are
not operational, the system/machine must be
shut down immediately.
Do not carry out any activities that might
jeopardize safety.
Note also the information in sections “Warranty and
liability”, “Use of operating instructions)”, “Compliance with other rules and instructions”, “Personnel
requirements”, “Remaining risks”.
Modification
We define modification as the replacement of a
defective valve with a new valve of the same series.
In particular, it is not permitted to open the valve.
Make sure that the hydraulic system/machine
is unpressurised before the product is installed/removed.
Service/maintenance
Service work may only be carried out by
qualified personnel. Detailed knowledge of
the machine functions concerning switching
on and off as well as of the required safety
relevant technical tasks is required!
Periodical maintenance is essential for the longevity
of the system and guarantees reliability and availability. The following properties of the system has
to be checked in continuous short time intervals:
• oil level in the tank
• max. working temperature
• condition of the pressure fluid (visual inspection,
color and smell of hydraulic fluid)
• working pressure levels
• gas pre-load pressure on the pressure accumulator
• leakage on all system components
• condition of filter elements
• condition of hose lines
• cleanliness of components
After a certain operating duration a change of the
hydraulic fluid is required. The frequency of change
depends from the following circumstances:
• kind resp. grade of the pressure fluid
• filtering
• operating temperature and environmental
conditions
Air bleeding of hydraulic system
During initial startup, after an oil change as well as
after the opening of lines or valves the hydraulic
system must be air bleeded.
Filter
The function and lifetime of the valve are strongly
affected by the cleanliness of the fluid.
Purity level class of 18/16/13 acc. ISO 4406 is
required.
Flushing
It is recommended to flush the pipelines by short
circuiting the pressure and return lines. This prevents
the installation dirt from entering the valve.
Decommissioning
Make sure that the hydraulic system/machine is
unpressurised before the product is removed. Note
also the information in sections “Warranty and
liability”, “Use of operating instructions”, “Compliance with other rules and instructions”, “Personnel
requirements”, “Remaining risks”.
Disposal
At the end of the service life of this product
• all escaping pressure fluids must be removed
and disposed of properly
• any significant fluids remaining in the product
must be removed and disposed of properly
• all materials must be segregated for recycling
when they are removed and taken to a suitable
recycling center.
Please segregate the packaging material properly
(e.g. paper, plastic). None of the components of the
product contain hazardous materials.
The normal local environmental protection
laws must always be met when disposing the
product.
Note also the information in sections “Warranty and
liability”, “Basic information on using the manual”,
"Other applicable standards/rules", “Personnel
requirements”, “Remaining risks”.
D_FC 5715-686 UK 07.02.2019
23
Parker Hannifin Corporation
Page 24
Proportional DC Valves
Operation Manual
Trouble shooting
Basis of troubleshooting is always a systematic
approach. At first the following questions have to
be checked:
• Are there practical experiences with similar
failures?
• Have system adjustments been changed?
Afterwards starting of troubleshooting by means of
a priority list of the most likely reasons.
For suspect of a sluggish spool the valve may
be flushed with clean pressure fluid.
Troubleshooting table
malfunction at hydraulic load runtime
- generally no function
- high frequent oscillation
- low frequent oscillation
- one way operation only
- speed variations at unchanging command
- different speeds depending on travel direction
- speed too low
- drifting without command
- poor dynamic
Xhydraulic pump resp. motor defectivereplace hydraulic pump resp. motor
XX X X X XX drive overloadedreduce pressure resp. speed, increase valve size
XX X X X X X X valve contaminatedclean pressure fluid, filter / flush valve
XX Xtoo low oil level within tankrefill pressure fluid
XXXcommand signal too lowincrease command signal
X XXX Xcontacts of central connector contaminatedclean contacts / replace plug
Xfeed cable interruptedfix feed cable
X X X X XX Xwir ing sequence incorrectcorrect wiring sequence
Xpilot pressure too low or failedincrease pilot pressure to min. 20 bar
XXX hydraulic fluid too viscous / too coldchange fluid grade, provide operational temperature
X X Xfilter contaminatedclean resp. replace filter
Xsupply voltage carries too much ripplereduce ripple
Xcommand signal carries too much ripplereduce ripple
XXcenter position adjustment incorrectcheck center position adjustment
XXfeed cable without shieldingchange cable grade
XX Xpilot pressure too lowincrease pilot pressure to min. 20 bar
possible reasons for malfunctioncorrective actions
X pilot pressure too lowincrease pilot pressure to min. 50 bar
Series D*FC, D*1FC
Troubleshooting in a hydraulic system requires
in either case a systematic approach. The
work may exclusively be performed by
qualified personnel, as it requires detailed
knowledge about function and construction
of the system. Reversals or disassemblies
may not be taken imprudently! Prior to the
works it has to be clarified, if the system has
been operated properly until the failure occured.
4. Product information
Other applicable standards / rules
• ISO 4406:1999-12 Hydraulic fluid power - Fluids
- Method for coding the level of contamination
by solid particles
• ISO 4401:2005-07 Hydraulic valves; mounting
surfaces and connecting plates
• DIN EN 60204-1; VDE 0113-1:2007-06 Safety of
machinery – Electrical equipment of machines
– Part 1: General requirements
• DIN EN 60529; VDE 0470-1:2000-09 Degrees
of protection provided by enclosures (IP code)
D_FC 5715-686 UK 07.02.2019
• DIN EN 61000-4-2/3/4/6/8 Electromagnetic
compatibility
• DIN 51524-1:2006-04 Pressure fluids - HLP
hydraulic oils - Part 1: Minimum requirements
• DIN 51525-2:2006-04 Pressure fluids - HLP
hydraulic oils - Part 2: Minimum requirements
• German Occupation Safety Ordinance (Betriebssicherheitsverordnung)
• German Labour Protection Act (Arbeitsschutzgesetz)
24
Parker Hannifin Corporation
Page 25
Operation Manual
Accessories / spare parts
Proportional DC Valves
Series D*FC, D*1FC
Accessories
The following accessories are available for the valve
series D*FC/D*1FC: