Parker D1FB EE, D1FB EEXG371, Design 18 Operating Instructions Manual

Bulletin MSG11-5715-704/UK
Operating instructions Series D1FB*EE
Design series 18
II 2 G c T4 Gb
-20 °C Ta +40 °C D1FB*EEXG371:
-20 °C Ta +60 °C
Direct Operated Proportional DC Valve
Parker Hannifin Manufacturing Germany GmbH & Co. KG
Industrial Systems Division Europe Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+49) 181 99 44 43 0 E-mail: valvesisde@parker.com Copyright © 2018, Parker Hannifin Corp.
Operating Instructions
WARNING - USER RESPONSIBILITY
Direct Operated Proportional DC Valve
Series D1FB*EE Explosion Proof
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.
D1FB-EE 5715-704UK 07.01.19
2
Parker Hannifin Corporation
Direct Operated Proportional DC Valve
Operating Instructions
Contents Page
0. EC declaration of conformity 4
1. Introduction 8
Ordering code 9
Technical data 11
Characteristic curves 12
Dimensions 14
Name plate 15
2. Safety instructions 15
Symbols 15
Marking, name plates 15
Work on the valve 15
3. Important information 16
Correct use 16
Common instructions 16
Liability 16
Storage 16
4. Installation 17
Scope of delivery 17
Installation 17
Electrical connection 18
Operation limits 18
Pressure fluids 18
5. Operating instructions 19
Electronic control system 19
Air bleeding of hydraulic system 19
Filter 19
Flushing 19
6. Maintenance 19
Replacement of a coil 19
7. Troubleshooting 21
A1 Extract from standards/directives 21
A2 User guide – Solenoid 23
A3 Type-examination certificate – Solenoid 25
A4 Declaration of conformity - Solenoid 39
A5 Mounting instruction cable gland 40
Series D1FB*EE Explosion Proof
D1FB-EE 5715-704UK 07.01.19
3
Parker Hannifin Corporation
Operating Instructions
0. EC declarations of conformity
Direct Operated Proportional DC Valve
Series D1FB*EE Explosion Proof
D1FB-EE 5715-704UK 07.01.19
4
Parker Hannifin Corporation
Operating Instructions
Direct Operated Proportional DC Valve
Series D1FB*EE Explosion Proof
D1FB-EE 5715-704UK 07.01.19
5
Parker Hannifin Corporation
Operating Instructions
Direct Operated Proportional DC Valve
Series D1FB*EE Explosion Proof
D1FB-EE 5715-704UK 07.01.19
6
Parker Hannifin Corporation
Operating Instructions
Direct Operated Proportional DC Valve
Series D1FB*EE Explosion Proof
D1FB-EE 5715-704UK 07.01.19
7
Parker Hannifin Corporation
Operating Instructions
a 0 b
A B
PT
AB
1. Introduction
The D1FB*EE series with explosion proof solenoids is based on the standard D1FB series. The specific solenoid design allows the usage in hazardous environments. The explosion proof class is
Ex e mb IIC T4 Gb
for use in zone 1 and 2 (conform to ATEX).
Additionally the solenoids are IECEx compliant.
The parameters can be saved, changed and dupli­cated in combination with the digital power amplifier PWD00A-400 (to be used in an explosion proof cabinet or outside of the hazardous area).
The valve parameters can be edited with the com­mon ProPxD software.
The D1FB valves can be ordered with spool/sleeve design (D1FB*0) for maximum precision as well as spool/body design (D1FB*3) for high nominal flow - see functional limit curves for maximum flow capability.
Features
• Spool/sleeve and spool/body
• High repeatability from valve to valve
• Low hysteresis
• Manual override
• Optional: coil to permit ambient temperature up to +60 °C modification XG371
Direct Operated Proportional DC Valve
Series D1FB*EE Explosion Proof
D1FB*0*EE
Spool/sleeve design
D1FB-EE 5715-704UK 07.01.19
D1FB*3*EE
Spool/body design
8
Parker Hannifin Corporation
Direct Operated Proportional DC Valve
Operating Instructions
Technical data
General
Design Direct operated proportional DC valve Actuation Proportional solenoid Size Mounting interface DIN 24340 / ISO 4401 / CETOP RP121 / NFPA Mounting position unrestricted Ambient temperature [°C] -20...+40; XG371: -20...+60 MTTFD value [years] 150 Weight [kg] 3.5 (2 solenoids), 2.5 (1 solenoid)
Hydraulic
Max. operating pressure [bar] Ports P, A, B 350; Port T 210 Max. pressure drop PABT / PBAT [bar] 350 Fluid Hydraulic oil as per DIN 51524...535, other on request Fluid temperature Viscosity permitted [cSt] / recommended [cSt] / Filtration ISO 4406 (1999) ; 18/16/13 Nominal flow at p=5 bar per control edge * Leakage at 100 bar [ml/min] <50 <60 Overlap [%] 25, electrically normalized at 10 (see flow characteristics)
Static / Dynamic
Step response at 100 % step [ms] 30 30 Hysteresis [%] <4 <6 Temperature drift solenoid current [%/K] <0.02
Electrical characteristics
Duty ratio [%] 100 Protection class Solenoid Supply voltage [V] 24 24 12 Current consumption [A] 1.15 1.0 2.3 Resistance [Ohm] 12.0 12.0 3.0
Solenoid connection
Wiring min. [mm²] 3 x 1.5 recommended Wiring length max. [m] 50 recommended
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
NG06/CETOP 03/NFPA D03
[°C] -20...+40; XG371: -20...+60
[mm2/s]
20...400
[mm2/s]
30...80
[l/min] 6 / 12 / 20 10 / 20 / 30
D1FB*0*EE (Spool/sleeve) D1FB*3*EE (Spool/body)
Box with M20x1.5 entry for cableglands. Solenoid identifications per ISO
9461.
Series D1FB*EE Explosion Proof
, Ex e mb IIC T4 Gb, IP66 (plugged and mounted correctly)
J J*XG371 K
* Flow rate for different p per control edge: Qx = Q
∆p
D1FB-EE 5715-704UK 07.01.19
Nom.
·
p
9
x
Nom.
Parker Hannifin Corporation
Operating Instructions
Ordering code
Direct Operated Proportional DC Valve
Series D1FB*EE Explosion Proof
Directional
control
valve
D1FB*0*EE: Spool/sleeve design
Code Spool type
E01C E01F E01H
E02C E02F E02H
E03C E03F E03H
QB = QA /2
B31F B31H
QB = QA /2
B32F B32H
D1FB*3*EE: Spool/body design
Code Spool type
E01F E01H E01K E02F E02H E02K
QB = QA /2
B31F B31H B31K
QB = QA /2
B32F B32H B32K
per metering edge
per metering edge
DIN NG06 CETOP 03 NFPA D03
Flow [l/min] at p 5 bar
6
12
20
6
12
20
6
12
20
12 / 6
20 / 10
12 / 6
20 / 10
Flow [l/min] at p 5 bar
10 20 30 10 20 30
10 / 15 20 / 10 30 / 15
10 / 15 20 / 10 30 / 15
1 F B 0D
Size
Proportional
control
Standard dynamics
standard
repeatability
Spool Spool position
N
Seals
NBR
(other seal compounds on request)
Code Spool position
C
E
K

D1FB-EE 5715-704UK 07.01.19
10
Parker Hannifin Corporation
Operating Instructions
E EE
Direct Operated Proportional DC Valve
Series D1FB*EE Explosion Proof
Explosion
proof
DesignSolenoid
Design series
(not required for
ordering)
Connection
Explosion proof
with cable glands
Ex e mb IIC T4 Gb
+ IECEx conformity
Modification
XG371
Code Modification
omit Standard
Coil to permit ambient
temperature up to +60 °C
Code Design
0 Spool/sleeve design
3 Spool/body design
Code Solenoid
K 12 V / 2.3 A
J 24 V / 1.15 A
J*XG371 24 V / 1.0 A
D1FB-EE 5715-704UK 07.01.19
11
Parker Hannifin Corporation
Direct Operated Proportional DC Valve
Flow Q [% of nominal flow]
100 -80 -60 -40 -20 0 20 40 60 80 100
100
75
50
25
0
Spool type B*
Command signal [%]
P-B
A-T
P-A
B-T
100 -80 -60 -40 -20 0 20 40 60 80 100
100
75
50
25
0
Spool type B*
P-B
A-T
P-A
B-T
Flow Q [% of nominal flow]
Command signal [%]
Flow Q [% of nominal flow]
100 -80 -60 -40 -20 0 20 40 60 80 100
100
75
50
25
0
Spool type E*
P-B A-T
P-A B-T
Command signal [%]
Flow Q [% of nominal flow]
100 -80 -60 -40 -20 0 20 40 60 80 100
100
75
50
25
0
Spool type E*
P-B A-T
P-A B-T
Command signal [%]
Flow Q [l/min]
Pressure drop p [bar]
P–T
40
350
Operating Instructions
Flow characteristics
at p = 5 bar per metering edge
D1FB*0*EE D1FB*0*EEXG371
Series D1FB*EE Explosion Proof
Functional limits
at 25 %, 50 %, 75 % and 100 % command signal (symmetric flow)
At asymmetric flow a reduced flow limit has to be considered – typically approx. 10 % lower.
Spool type E01H Spool type E01H*XG371
30
20
10
12
0
0
All characteristic curves measured with HLP46 at 50 °C.
D1FB-EE 5715-704UK 07.01.19
AB
PT
100 %
75 %
50 %
25 %
30025020015010050
Parker Hannifin Corporation