Parker Compax3M, Compax3M150D6, Compax3M300D6, Compax3M050D6, Compax3M100D6 Short Description

Page 1
Multi-axis devices
Electromechanical Automation
Compax3M Short Description
Multi-axis devices
English......Page 1...20
Deutsch...Seite 21...40
Français..Page 42...60
We reserve the right to make technical changes. The data correspond to the current status at
the time of printing.
DOC-0012-03
DOC-0012-03
192-120148N13
2019-06
192-120148N13 2019-06
Page 2
Notes on the Documents Supplied
____________________________
Windows NT®, Windows 2000™, Windows XP™, Windows Vista, Windows 7 are trademarks of Microsoft Corporation. EtherCAT® is a registered trademark and a patented technology of Beckhoff Automation GmbH, Germany. CoDeSys® is a registered trademark of 3S-Smart Software Solutions GmbH. PROFINET is a registered trademark of Profibus and PROFINET International. Ethernet/IP is a trademark of Open DeviceNet Vendor Association.
Non-warranty clause
We checked the contents of this publication for compliance with the associated hard and software. We can, however, not exclude discrepancies and do therefore not accept any liability for the exact compliance. The information in this publication is regularly checked, necessary corrections will be part of the subsequent publications. German Master created.
Production site:
Parker Hannifin Manufacturing Germany GmbH & Co. KG Electromechanical & Drives Division [EME] Robert-Bosch-Strasse 22 77656 Offenburg (Germany) Tel.: + 49 (0781) 509-0 Fax: + 49 (0781) 509-98176 Internet: www.parker.com/eme http://www.parker.com/eme E-mail: sales.automation@parker.com mailto:EM-Motion@parker.com
Multi-axis devices
Parker Hannifin GmbH - registered office: Bielefeld HRB 35489 Management Board: Ellen Raahede Secher, Dr.-Ing. Hans-Jürgen Haas, Günter Schrank, Kees Veraart - Chairman of the board: Hansgeorg Greuner
Italy:
Parker Hannifin Manufacturing Srl Electromechanical & Drives Division [EME] Via C. Gounod, 1 20092 Cinisello Balsamo (Milano), Italy Tel.: + 39 (0)2 361081 Fax: + 39 (0)2 36108400 Internet: www.parker.com/eme http://www.parker.com/eme E-mail: parker.italy@parker.com mailto:parker.italy@parker.com
Location USA:
Parker Hannifin Corporation • Electromechanical Automation 5500 Business Park Drive • Rohnert Park, CA 94928 Phone #: (800) 358-9068 • FAX #: (707) 584-3715 E-mail: CMR_help@parker.com mailto:emn_support@parker.com • Internet:
www.parker.com/emn http://www.parker.com/emn Unser Produkt im Internet: http://www.parker.com/eme/c3 Downloads http://solutions.parker.com/c3_support
2 192-120148N13 2019-06
Page 3
Parker EME
Operating system:
MS Windows XP SP3 / MS Vista (32 Bit) / Windows 7 (32 Bit / 64 Bit)
Browser:
MS Internet Explorer 8.x or higher
Processor:
Intel / AMD Multi core processor >=2GHz
Hard disk:
>= 20GB available memory
Monitor:
Resolution 1024x768 or higher
Graphics card:
on onboard graphics (for performance reasons)
Interface:
USB 2.0
1. Notes on the Documents Supplied
Compax 3 - short
reference guide
Online help system
This short reference guide does contain only the basic information; for more
detailed information please refer to the Help-files of the individual Compax3
device types.
Compax3 - Download page: http://solutions.parker.com/c3_Support
Here you find the Compax3 ServoManager, Firmware, Field Bus Files, Targets and Application examples.
C3 ServoManager
After the inst system with the "C3 ServoManager Help Installer" (you can select the C3 device type as well as the desired language) to your PC. The help system can be called up directly from the ServoManager. You will find the complete description of the selected device type in these online help files. Please note that the help files are associated with defined device and software versions.
Status of the Manuals:
Help and PDFs are updated simultaneously. In case of doubt the HTML help shows the actual state in comparison to PDF edition. For additional HTLM help please refer to our website.
allation of the ServoManager you can copy the desired Online help
1.1 C3 ServoManager
PC requirements
Minimum requirements:
User : >= 1024MB
Note:
For the installation of the software you need administrator authorization on the
target computer.
192-120148N13 2019-06 3
Page 4
Notes on the Documents Supplied
Content
Connection
PC-PSUP
Device Selection
Configuration
Your PC is connected to the PSUP (mains module) connector X3 via an USB cable (SSK33/03). Start the Compax3 servo manager and make the setting for the assigned interface in the menu"Options: Communication settings RS232/RS485...". The interface is marked as "USB Serial Port (COMx)" in the windows device manager. The no. of the COM port "x" may vary. You can find it in the PC under system control, system, hardware, device manager, connections.
In the menu tree under device selection you can read the device type of the connected device (Online Device Identification) or select a device type (Device Selection Wizard).
Then you can double click on "Configuration" to start the configuration wizard. The wizard will lead you through all input windows of the configuration.
Multi-axis devices
1. Notes on the Documents Supplied ........................................................ 3
1.1 C3 ServoManager ..................................................................................... 3
2. Introduction ............................................................................................. 5
2.1 Device assignment .................................................................................. 5
2.2 Scope of delivery ..................................................................................... 5
2.3 Type specification plate .......................................................................... 5
2.4 Packaging, transport, storage ................................................................ 7
2.5 Safety instructions ................................................................................... 8
2.5.1. General hazards ................................................................................................. 8
2.5.2. Working safely / qualification ........................................................................... 8
2.5.3. Special dangers ................................................................................................. 8
2.6 Warranty conditions ................................................................................ 9
2.7 Conditions of utilization .......................................................................... 9
2.7.1. Conditions of utilization for CE-conform operation ....................................... 9
2.7.2. Conditions of utilization for UL approval Compax3M .................................. 11
2.7.3. Conditions of utilization for UL approval PSUP ........................................... 12
2.7.4. Current on the mains PE (leakage current) ................................................... 13
2.7.5. Supply networks .............................................................................................. 13
2.8 EC declaration of conformity Compax3M ............................................ 14
2.9 EC declaration of conformity PSUP ..................................................... 15
3. Device description ................................................................................ 16
3.1 Installation instructions Compax3M .................................................... 16
3.2 Mounting and dimensions ..................................................................... 17
3.2.1. Mounting and dimensions PSUP10/C3M050D6, C3M100D6,
C3M150D6 ......................................................................................................... 17
3.2.2. Mounting and dimensions PSUP20/PSUP30/C3M300D6 ............................. 18
4. Technical Data ....................................................................................... 19
4 192-120148N13 2019-06
Page 5
Parker EME
EC declaration of conformity PSUP ................................................................................. 15
2. Introduction
Type specification
(example)
In this chapter you can read about:
Device assignment ............................................................................................................ 5
Scope of delivery ............................................................................................................... 5
Type specification plate ..................................................................................................... 5
Packaging, transport, storage ............................................................................................ 7
Safety instructions ............................................................................................................. 8
Warranty conditions ........................................................................................................... 9
Conditions of utilization ...................................................................................................... 9
EC declaration of conformity Compax3M ......................................................................... 14
2.1 Device assignment
This manual is valid for the following devices:
Compax3M050D6 + supplementCompax3M100D6 + supplementCompax3M150D6 + supplementCompax3M300D6 + supplement
Device assignment
PSUP10D6 (mains module)PSUP20D6 (mains module)PSUP30D6 (mains module)
2.2 Scope of delivery
Device accessories
Device accessories for Compax3M
Cable clamps in different sizes for large area shielding of the motor cable, the
screw for the cable clamp as well as
the matching plug for the Compax3M connectors X14, X15, X43a toroidal core ferrite for a cable of the motor holding brakean interface cable (SSK28/23) for communication within the axis combinationWith safety option S3: Mating plugs X28 and connection cable X26 / X27
2.3 Type specification plate
The present device type is defined by the type specification plate (on the housing):
plate: PSUP
192-120148N13 2019-06 5
Page 6
Introduction
1
Type designation: The complete order designation of the device (2 - 4).
2
PSUPx0:Mains module 3AC 230...480V, nominal power in 1kW (10=10kW)
D6: Designation nominal supply
4
Options: Mxx: I/O extension
5
Unique number of the particular device
6
Date of factory test
7
Nominal supply voltage: Power Input: Input supply data / Power Output: Output data
8
CE compliance
9
1
Type designation: / The complete order designation of the device (2, 5, 6, 9, 8).
C3: Abbreviation for Compax3
H050: High power device, nominal device current in 1A (050=50A)
D6: Designation nominal supply V2: Mains supply voltage (2=230VAC/240VAC, 4=400VAC/480VAC)
3
Unique number of the particular device
Nominal supply voltage Power Input: Input supply data / Power Output: Output data
F12: Feedback module for direct drives
Device interface
C20:
7
Date of factory test
8
Options: Mxx: I/O extension, HEDA / Sx: optional safety technology on C3M
Technology function
T30: Motion control in accordance with IEC61131-3 / T40: Electronic cam
10
CE compliance
11
Certified safety technology (corresponding to the logo displayed)
Compax3 - Type
(example):
Multi-axis devices
specification plate
Explanatio
3 Configuration and parameterization interface: USB:USB connection
n:
UL certified (corresponding to the logo displayed on the device)
Explanation:
S025: Single axis device, nominal device current in 100mA (025=2.5A)
2
M050: Multi-axis device, nomi nal device current in 100mA (050=5A)
4
Designation of the feedback system
F10: Resolver / F11: SinCos© / Single- or Multiturn
5
I10: Analog, step/direction and encoder input I11 / I12: Digital Inputs / Outputs and RS232 / RS485
6
I20: Profibus DP / I21: CANopen / I22: DeviceNet / I30: Ethernet Powerlink / I31: EtherCAT / I32: Profinet
integrated controller C3 powerPLmC, Linux & Web server
T10: Servo controller / T11: Positioning / T20: Pressure / Volume flow rate
9
12
UL certified (corresponding to the logo displayed)
6 192-120148N13 2019-06
Page 7
Parker EME
lethal fumes may develop.
suitable for recycling
Plastic materials
yes
no
2.4 Packaging, transport, storage
Packaging material and transport
Caution!
The packaging material is inflammable, if it is disposed of improperly by burning,
Packaging, transport, storage
First device checkup
Disposal
The packaging materi
al must be kept and reused in the case of a return shipment. Improper or faulty packaging may lead to transport damages. Make sure to transport the drive always in a safe manner and with the aid of suitable lifting equipment (Weight (see on page 18)). Do never use the electric connections for lifting. Before the transport, a clean, level surface should be prepared to place the device on. The electric connections may not be damaged when placing the device.
Check the device for signs of transport damages.Please verify, if the indications on the Type identification plate (see on page 5)
correspond to your requirements.
Check if the consignment is complete.
This product contains materials that fall under the special disposal regulation from 2010, which corresponds to the EC directory 2008/98/EC for dangerous disposal material. We recommend to dispose of the respective materials in accordance with the respectively valid environmental laws. The following table states the materials suitable for recycling and the materials which have to be disposed of separately.
Material
Metal yes no
Circuit boards no yes
Disposal
Please dispose of the circuit boards according to one of the following methods:
Burning at high temperatures (at least 1200°C) in an incineration plant licensed in
accordance with part A or B of the environmental protection act.
Disposal via a technical waste dump which is allowed to take on electrolytic
aluminum condensers. Do under no circumstances dump the circuit boards at a place near a normal waste dump.
Storage
Please note in the event of storage >1 year:
If you do not wish to mount and install the device immediately, make sure to store it in a dry and clean environment. Make sure that the device is not stored near strong heat sources and that no metal chippings can get into the device.
Forming the capacitors
Forming the capacitors only required with 400 VAC axis controllers and
mains module PSUP
If the device was stored longer than one year, the intermediate capacitors must be re-formed!
Forming sequence:
Remove all electric connectionsSupply the device with 230VAC single phase for 30 minutes
via the L1 and L2 terminals on the device orwith multi axis devices via L1 and L2 on the mains module PSUP.
192-120148N13 2019-06 7
Page 8
Introduction
this case, the user is liable to take suitable measures.
Caution - Risk of Electric Shock!
supply.
2.5 Safety instructions
2.5.1. General hazards
General Hazards on Non-Compliance with the Safety Instructions The device described in this manual is des igned in ac c ordanc e with the lat es t technology and is safe in operation. Nevertheless, the device can entail certain hazards if used improperly or for purposes other than those explicitly intended. Electronic, moving and rotating components can
cause danger for life and limb of the operator andmaterial damage
Designated use
The device is designed for operation in electric power drive systems (VDE0160). Motion sequences can be automated with this device. Several motion sequences can be can combined by interconnecting several of these devices. Mutual interlocking functions must be incorporated for this purpose.
2.5.2. Working safely / qualification
This device may be operated only by qualified personnel. Qualified personnel in the sense of these operating instructions consists of:
Persons who, by virtue to their training, experience and instruction, and their
knowledge of pertinent norms, specifications, accident prevention regulations and operational relationships, have been authorized by the officer responsible for the safety of the system to perform the required task and in the process are capable of recognizing potential hazards and avoiding them (definition of technical personnel according to VDE105 or IEC364),
who have a knowledge of first-aid techniques and the local emergency rescue
services,
who have read and will observe the safety instructions,who have read and observe the manual or help (or the sections pertinent to the
work to be carried out). This applies to all work relating to setting up, commissioning, configuring, programming, modifying the conditions of utilization and operating modes, and to maintenance work. This manual and the help information must be available close to the device during the performance of all tasks.
Multi-axis devices
2.5.3. Special dangers
Danger!
Due to movable machine parts and high voltages, the device can pose a lethal danger. Danger of electric shock in the case of non-respect of the following instructions. The device corresponds to DIN EN 61800-3, i.e. it is subject to limited sale. The device can emit disturbances in certain local environments. In
Always switch off devices before wiring them! Dangerous voltages are still present until 10 min. after switching off the power
8 192-120148N13 2019-06
Check that all live terminals are secured against contact. Perilous voltage levels
of up to 850V occur.
Do not bypass power direct current.
The device must be permanently grounded due to high earth leakage currents.The drive motor must be grounded with a suitable protective lead.The devices are equipped with high voltage DC condensers. Before removing the
protective cover, the discharging time must be awaited. After switching off the
supply voltage, it may take up to 10 minutes (with additional capacity modules it
may take up to 30 minutes) to discharge the capacitors.
Danger of electric shock in case of non respect.
Page 9
Parker EME
Mains filter:
A mains filter is required in the mains input line if the motor cable exceeds a separately for jeden Achsverbund.
Before you can work on the device, the supply voltage must be switched off at the
Warranty conditions
L1, L2 and L3 clamps. Wait at least 10 minutes so that the power direct current
may sink to a secure value (<50V). Check with the aid of a voltmeter, if the
voltage at the DC+ and DC- clamps has fallen to a value below 50V.
Danger of electric shock in case of non respect.
Do never perform resistance tests with elevated voltages (over 690V) on the
wiring without separating the circuit to be tested from the drive.
Please exchange devices only in currentless state and, in an axis system, only in
a defined original state.
If the axis controller is replaced, it is absolutely necessary to transfer the
configuration determining the correct operation of the drive to the device, before
the device is put into operation. Depending on the operation mode, a machine
zero run will be necessary.
The device contains electrostatically sensitive components. Please heed the
electrostatic protection measures while working at/with the device as well as
during installation and maintenance.
2.6 Warranty conditions
The device must not be opened.Do not make any modifications to the device, except for those described in the
manual.
Make connections to the inputs, outputs and interfaces only in the manner
described in the manual.
Fix the devices according to the mounting instructions. (see on page 17)
We cannot provide any guarantee for other mounting methods.
Note on exchange of options
Device options must be exchanged in the factory to ensure hardware and software compatibility.
When installing the device, make sure the heat dissipators of the device receive
sufficient air and respect the recommended mounting distances of the devices
with integrated ventilator fans in order to ensure free circulation of the cooling air.
Make sure that the mounting plate is not exposed to external temperature
influences.
2.7 Conditions of utilization
2.7.1. Conditions of utilization for CE-conform operation
- Industry and trade -
The EC guidelines for electromagnetic compatibility 2014/30/EU and for electrical operating devices for utilization within certain voltage limits 2014/35/EU are fulfilled when the following boundary conditions are observed:
Operation of devices only in the state in which they are delivered.
In order to ensure contact protection, all mating plugs must be present on the device connections e ve n if they are not wired. Please respect the specifications of the manual resp. of the help function, especially the technical characteristics (mains connection, circuit breakers, output data, ambient conditions,...).
2.7.1.1 Conditions of utilization mains filter
certain length. Filtering can be provided centrally at the system mains input or
Use of the devices in a commercial and residential area (limit value class in accordance with EN 61800-3)
The following mains filters are available for independent utilization:
192-120148N13 2019-06 9
Page 10
Introduction
Device: PSU
Limit value class
Reference: Axis system with motor cable
Mains filter Order No.:
P10
C3
< 6 x 10 m
NFI03/01
P10
C3
< 6 x 50 m
NFI03/02
P20
C3
< 6 x 50 m
NFI03/03
P30
C3
< 6 x 50 m
NFI03/03
unshielded:
< 0.5 m
shielded
< 5 (fully shielded on ground - e.g. ground of control cabinet)
Motor and Feedback
cable:
Operation of the devices only with motor and feedback cables whose plugs contain a special full surface area screening.
Shielding connection of
the motor cable
The cable must be fully-screened and connected to the device housing. Use the
(via plug or screw in the terminal box) depends on the motor type.
Cable installation:
Signal lines and power lines should be installed as far apart as poss ib le.
Do not place mains filter output cable parallel to the load cable.
Motors:
Operation with standard motors.
Control:
Use only with aligned controller (to avoid control loop oscillation).
Grounding:
Connect the filter housing and the device to the cabinet frame, making sure that
Never mount the filter housing and the device on paint-coated surfaces!
Accessories:
Make sure to use only the accessories recom m ended b y Park er .
This is restricted operation category product according to EN 61800-3. This product suitable action if this proves to be the case.
Compax3M motor
cable
Compax3M encoder
cable:
Cable
Multi-axis devices
Use of the devices in the industrial area (limit values class C3 in accordance with EN 61800-3)
The following mains filters are available for independent utilization:
Connection length: Connection between mains filter and device:
2.7.1.2 Conditions of utilization for cables / motor filter
<80m per axis (the cable must not be rolled up!) The entire length of the motor cable per axis combination may not exceed 300m. A motor output filter is required for motor cables >20 m:
ECM-0001-04 (max. 6.3 A nominal motor current)ECM-0001-01 (max. 16 A nominal motor current)
ECM-0001-02 (max. 30 A nominal m otor current)
cable clamps/shield connecting terminals furnished with the device. The shield of the cable must also be connected with the motor housing. The fixing
< 80m
Correspondi of up to 60°C.
Signal lines should never pass close to excessive sources of interference
ng to the specifications of the terminal clamp with a temperature range
(motors, transformers, contactors etc.).
2.7.1.3 Additional conditions of utilization
the contact area is adequate and that the connection has low resistance and low inductance.
Connect all cable shields at both ends, ensuring large contact areas!
can cause high-frequency disturbance in domestic areas. Users are asked to take
10 192-120148N13 2019-06
Page 11
Parker EME
Conform to UL:
in accordance with UL508C
Certified
E-File_No.: E235342
The UL approval is documented by a
Device
X43: Motor connector
X15: Temperature monitoring
C3M050-150
C3M300
Discharge time of the bus capacitor is 10 minutes.
Compax3 device:
Cross-section: Minimum... Maximum [with conductor sleeve]
M050, M100, M150
0.25 ... 4 mm2 (AWG: 23 ... 11)
M300
0.5 ... 6 mm2 (AWG: 20 ... 10)
Conditions of utilization
2.7.2. Conditions of utilization for UL approval Compax3M
UL approval for Compax3M
“UL” logo on the device (type specification plate).
Condition
The devices are only to be installed in a degree of contamination 2 environment
s of utilization
(maximum).
The devices must be appropriately protected (e.g. by a switching cabinet).Tightening torque of the field wiring terminals ( green Phoenix plugs)
0.5Nm (4.43Lb.in) 0.22Nm (1.95Lb. i n )
1.2Nm (10.62Lb.in) 0.22Nm (1.95Lb. i n )
Temperature rating of field installed conductors shall be at least 60°C. Use
copper lines only
Please use the cables described in the acc es sor ies chapter, they feature a
temperature rating of at least 60°C.
Maximum Surrounding Air Temperature: 40°C.Control voltage supply (24VDC) only permissible with "class 2" power supply.
Compax3M may only be operated with a mains module of the PSUP series.Motor Over Temperature sensing is not provided by the drive unless the external
temperature sensor is connected.
Caution!
Risk of electric shock.
The drive provides internal motor overload protection. This must be set so that 200% of the motor nominal current are not exceeded.
Cable cross-sections
Mains input: corresponding to the recommended fuses.
Motor cable: corresponding to the Nominal output currentsMaximum cross-section limited by the terminals mm
2
/ AWG
Line cross-sections of the power connections (on the device bottoms)
192-120148N13 2019-06 11
Page 12
Introduction
Conform to UL:
in accordance with UL508C
Certified
E-File_No.: E235342
The UL approval is documented by a
Device
X40: Ballast resistor
X41: Mains connector
X9: 24VDC
PSUP30
Measure for line and device protection:
(ABB) S203UP-K25 (480VAC)
Maximum fuse rating per
2 special purpose fuses in line
Cable protection measure:
Bussmann 170M1366 or 170M1566D
Discharge time of the bus capacitor is 10 minutes.
Multi-axis devices
2.7.3. Conditions of utilization for UL approval PSUP
UL approval for mains modules PSUP
“UL” logo on the device (type specification plate).
UL approval PSUP30 in prepar at io n!
Conditions of utilization
The devices are only to be installed in a degree of contamination 2 environment
(maximum).
The devices must be appropriately protected (e.g. by a switching cabinet).Tightening torque of the field wiring terminals ( green Phoenix plugs)
PSUP10
PSUP20
Temperature rating of field installed conductors shall be at least 60°C. Use
0.5 Nm (4.43Lb.in) 1.2 Nm (10.62Lb.in)
0.5 Nm (4.43Lb.in) 1.7 Nm (15Lb.in)
UL approval in preparation
copper lines only
Please use the cables described in the accessories chapter, they feature a
temperature rating of at least 60°C.
Maximum Surrounding Air Temperature: 40°C.Control voltage supply (24VDC) only permissible with "class 2" power supply.Suitable for use on a circuit capable of delivering not more than 5000 rms
symmetrical amperes and 480 volts maximum and protected by (see below).
The devices need a "branch circ uit protec t ion ".
1.2 Nm
(10.62Lb.in)
1.2 Nm
(10.62Lb.in)
PSUP10D6
Maximum fuse rating per device
PSUP20D6
device
are required
Caution!
Risk of electric shock.
MCB miniature circuit breaker (K character ist ic) 25A in accordance with UL category DIVQ
MCB (K characteristic) with a rating of 50A / 4xxVAC (depending on the input voltage). (ABB) S203U-K50 (440VAC) Device protection measure:
Fuses 80A / 700VAC per supply leg in accordance with UL category JFHR2:
12 192-120148N13 2019-06
Page 13
Parker EME
This product can cause a direct current in the protective lead. If a residual current
instructions.
When grounding the neutral conductor, mains
When grounding an external conductor (delta
l
2.7.4. Current on the mains PE (leakage current)
device (RCD) is used for protection in the event of direct or indirect contact, only a type B (all current sensitive) RCD is permitted on the current supply side of this product . Otherwise, a different protective measure must be taken, such as separation from the environment by doubled or enforced insulation or separation from the mains power supply by means of a transformer.
Conditions of utilization
Respect the supplier's
Mains filt
ers do have high leakage currents due to their internal capacity. An internal mains filter is usually integrated into the servo controllers. Additional discharge currents are caused by the capacities of the motor cable and the motor winding. Due to the high clock frequency of the power output stage, the leakage currents do have high-frequency components. Please check if the FI protection switch is suitable for the individual application. If an external mains filter is used, an additional leakage current will be produced. The figure of the leakage current depends on the following factors:
Length and properties of the motor cableSwitching frequencyOperation with or without external mains filterMotor cable with or without shield networkMotor housing grounding (how and where)
Remark:
The leakage current is important with respect to the handling and usage safety of
the device.
A pulsing leakage current occurs if the supply voltage is switched on.
Please note:
The device must be operated with effective grounding connection, which must comply with the local regulations for high leakage currents (>3.5 mA). Due to the high leakage currents it is not advisable to operate the servo drive with an earth leakage circuit breaker.
2.7.5. Supply networks
This product is designed for fixed connection to TN networks (TN-C, TN-C-S or TN-S). Please note that the line-earth voltage may not exceed 300VAC.
voltages of up to 480VAC are permitted.
mains, two-phase mains), mains voltages (externa conductor voltages) of up to 240VAC are permitted.
Devices which are to be connected to an IT network must be provided with a separating transformer. Then the devices are operated locally as in a TN network. The secondary sided center of the separating transformer must be grounded and connected to the PE connector of the device.
192-120148N13 2019-06 13
Page 14
Introduction
2.8 EC declaration of conformity Compax3M
Multi-axis devices
14 192-120148N13 2019-06
Page 15
Parker EME
2.9 EC declaration of conformity PSUP
EC declaration of conformity PSUP
192-120148N13 2019-06 15
Page 16
Device description
Caution - Risk of Electric Shock!
Setup of the devices only with closed protective covers.
3. Device description
Multi-axis devices
3.1 Installation instructions Compax3M
General introductory notes
Operation of the Compax3M multi-axis combination is only possible in connection with a PSUP (mains
module).
Axis controllers are aligned at the right of the mains module.Arrangement within the multi-axis combination sorted by power (with the same device types according to
device utilization), the axis controller with the highest power is placed directly at the right of the mains module. e.g. first the device type with high utilization, at the right of this, the same device type with a lower utilization.
Max. 15 Compax3M (axis controllers) per PSUP (mains module) are permitted (please respect the total
capacity of max. 2400µF for PSUP10, max. 5000µF for PSUP20).
The continuation of the current rail connection outside the axis combination is not permitted and will lead to
a loss of the CE and UL approbation.
External components may not be connected to the rail system.
Required tools:
Allen key M5 for fixing the devices in the control cabinet.Crosstip screwdriver M4 for connection rails of the DC rail modules.Crosstip screwdriver M5 for grounding screw of the device.Flat-bladed screwdriver 0.4x2.5 / 0.6x3.5 / 1.0x4.0 for wiring and mounting of the phoenix clamps.
Order of installation
Fixing the devices in the control cabinet.
Predrilling the mounting plate in the control cabinet according to the specifications. Dimensions (see on
page 17). Fit M5 screws loosely in the bores.
Fit device on the upper screws and place on lower screw. Tighten screws of all devices. The tightening
torque depends on the screw type (e.g. 5.9Nm for M5 screw DIN 912 8.8).
Connection of the internal supply voltage.
The Compax3M axis controllers are connected to the supply voltages via the rail modules. Details.
Deblocking the yellow protective cover with a flat-bladed screwdriver on the upper surface (click
mechanism). Remove the closing devices (contact protection) that are not required from between the devices.
Connecting the rail modules, beginning with the mains module.
For this, loosen crosshead screws (5 screws at the right in the mains module, all 10 screws in the next axis controller), push the rails one after the other against to the left and tighten screws. Proceed accordingly for all adjacent axis controllers in the combination. Max. tightening torque: 1.5Nm.
Close all protective covers. The protective covers must latch audibly.
Please no
Insufficiently fixed screw connections of the DC power voltage rails may lead to the destruction of the devices.
Protective seals
Connect protective earth to mains module (M5 crosshead screw on front of device bottom).Connecting the internal communication. Details.Connecting the signal and fieldbus connectors. Details.Connection of mains power supply Details ballast resistor details and motor details.Connecting the configuration interface to the PC. Details.
te:
In order to secure the contact protection against the alive rails, it is absolutely necessary to respect the following:
Insert the yellow plastic comb at the left or right of the rails.
Make sure that the yellow plastic combs are placed at the left of the first device and at the right of the last device in the system and have not been removed.
16 192-120148N13 2019-06
Page 17
Parker EME
devices are sufficiently fixed.
Information on
PSUP10D6/C3M050D6, C3M100D6, C3M150D6
50mm
360mm
263mm
46mm
50,5mm
400mm
90°
Mounting and dimensions
3.2 Mounting and dimensions
Ventilation:
During operation, the device radiates heat (heat dissipation). Please provide for
a sufficient mounting distance below and above the device in order to ensure free circulation of the cooling air.
Please do also respect the recommended distances of other devices.Make sure that the mounting plate is not exhibited to other temperature
influences than that of the devices mounted on this very plate.
The devices must be mounted vertically on a level surface. Make sure that all
3.2.1. Mounting and dimensions PSUP10/C3M050D6, C3M100D6, C3M150D6
The devices are force-ventilated via a ventilator fan fixed to the lower part of the heat dissipator!
Mounting spacing: At the top and below: at least 100mm
Mounting:
2 socket head screws M5
Tolerances: DIN ISO 2768-f
192-120148N13 2019-06 17
Page 18
Device description
Information on
PSUP20/PSUP30/C3M300D6
100mm
360mm
263mm
96mm
90°
50,5mm 50,5mm
101mm
Multi-axis devices
3.2.2. Mounting and dimensions PSUP20/PSUP30/C3M300D6
Mounting:
4 socket head screws M5
Tolerances: DIN ISO 2768-f
18 192-120148N13 2019-06
Page 19
Parker EME
Device type PSUP10
230V
400V
480V
230VAC ±10% 50-60Hz
400VAC ±10% 50-60Hz
480VAC ±10% 50-60Hz
Rated voltage
3AC 230V
3AC 400V
3AC 480V
Input current
22Arms
22Arms
18Arms
Output Voltage
325VDC ±10%
565VDC ±10%
680VDC ±10%
Output power
6kW
10 kW
10 kW
Pulse power (<5s)
12kW
20kW
20kW
Heat dissipation
60W
60W
60W
Measure for line and device protection:
Recommendation: (ABB) S203UP-K25 (480VAC)
Device type PSUP20
230V
400V
480V
Supply voltage
50-60Hz
50-60Hz
50-60Hz
Rated voltage
3AC 230V
3AC 400V
3AC 480V
Input current
44Arms
44Arms
35Arms
Output Voltage
325VDC ±10%
565VDC ±10%
680VDC ±10%
Output power
12kW
20kW
20kW
Pulse power (<5s)
24kW
40kW
40kW
Heat dissipation
120W
120W
120W
Maximum fuse rating per
Cable protection measure:
Requirement: Bussmann 170M1366 or 170M1566D
Device type PSUP30
230V
400V
480V
Supply voltage
230VAC ±10% 50-60Hz
400VAC ±10% 50-60Hz
480VAC ±10% 50-60Hz
Rated voltage
3AC 230V
3AC 400V
3AC 480V
Input current
50Arms
50Arms
42Arms
Output Voltage
325VDC ±10%
565VDC ±10%
680VDC ±10%
Output power
17kW
30kW
30kW
Pulse power (<5s)
34kW
60kW
60kW
Heat dissipation
140W
140W
140W
Maximum fuse rating per
Cable protection measure:
Requirement: Bussmann 170M1368 or 170M1568D
4. Technical Data
Mains connection PSUP10D6
Supply voltage
Mounting and dimensions
Maximum fuse rating per device
Mains connection PSUP20D6
device 2 special purpose fuses in line are required
PSUP30D6 Mains connection
MCB miniature circuit breaker (K character ist ic) 25A in accordance with UL category DIVQ
230VAC ±10%
MCB (K characteristic) with a rating of 50A / 4xxVAC (depending on the input voltage) Recommendation: (ABB) S203U-K50 (440VAC) Device protection measure:
Circuit breakers 80A / 700VAC per supply leg in accordance with UL category JFHR 2
400VAC ±10%
480VAC ±10%
device 2 special purpose fuses in line are required
MCB (K characteristic) with a rating of 63A / 4xxVAC (depending on the input voltage) Recommendation: (ABB) S203U-K63 (440VAC) Device protection measure:
Circuit breakers 125A / 700VAC per supply leg in accordance with UL category JFHR2
192-120148N13 2019-06 19
Page 20
Technical Data
Multi-axis devices
20 192-120148N13 2019-06
Loading...