PARK AUDIO RX, RX9d Owner's Manual

series
9d
FOUR CHANNEL PROFESSIONAL
SWITCHING POWER AMPLIFIER
Owner’s Manual
ACCESSORIES
2. Dust filter 2 pcs
3. Owner’s Manual 1 pc.
4. Warranty 1 pc.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS
RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION!
The amplifier runs on 230 V AC voltage. Removing the cover will expose you to a potentially dangerous voltage! Do not use the unit if the electrical power cord is frayed or broken. Power is supplied from 230 V AC single-phase grounded 50/60 Hz source!
CAUTION!
To reduce the risc of fire or electric shock, do not expose the amplifier to rain or moisture!
CAUTION!
The amplifier can yield dangerous output voltage! Do not touch the non-insulated cable parts, connected to the unit in operation!
CAUTION!
The high sound pressure caused by the high output signal, applied to speaker systems, may endanger your hearing. Please, take care to observe the required safety precautions.
WARNING SIGNS:
Important information! Intended to warn the user about any important information contained in this Owner’s Manual.
Hazardous voltage inside! Intended to warn the user about electric shock hazard due to high voltage inside the product.
This sign next to the output terminals warns about dangerous voltage while in operation.
22
GENERAL
The four-channel professional power amplifier RX9d is designed for sound signal
high-fidelity amplification within professional sound reproduction systems.
The amplifier is equipped with built-in DSP engine (DFM audio, Germany), which
provides the precision processing of the audio signal. To control the parameters of the amplifier (or group of amplifiers) the program NetControl is used, the amplifiers are connected via the ETHERNET interface. To ensure faultless operation of amplifiers, please, take time to read this Manual before use.
WARNING!
Make sure to take all precautions where required. Please, follow all instructions and guidelines. To avoid any risk of electrical shock and/or fire hazard, please, do not expose this unit
to rain or moisture. Do not use this unit near open water. Use dry cloth to clean the unit. Do not block fan vents. Do not place the unit near heating radiators, furnaces or other heat-emitting devices. Do not connect this unit to an ungrounded power supply line. Protect the power cord against damage. Disconnect the unit from power supply in case of thunder or during downtime. In case of malfunctioning, caused by water or any other foreign matter inside or when
the unit has been dropped, or the power cord has been damaged, or the unit has been found faulty, please, consult qualified personnel.
WARNING!
The amplifier yields high output power. The manufacturer shall not be held respon­sible for any damage to the speakers caused by excessive power from the unit.
UNPACKING
The manufacturer’s quality control system provides for careful examination of each product before it leaves the factory to ensure its flawless appearance. After unpacking, please, check the unit for any physical damage. In case of damage, please, contact your local dealer. Keep the shipping carton and all packing material, as you may require them for reshipment of the unit.
3
DESIGN FEATURES
Physical Design
The amplifier is enclosed in a metal (steel) case of 2U height. The amplifier is designed to be installed into a standard 19" rack.
The amplifier must be fixed at four points, when installed in the RACK 19 "(two points in front and two at the rear).
Power Supply Unit
Two independent switch-mode PSU. Individual for each pair of channel.
Cooling System
Forced, cooling rate smooth adjustable system.
Two powerful fans. Backward air flow direction.
Dust Filter
Two removable filters are located on the front panel under protective covers.
Covers can be removed and installed without the use of any tools.
Power Amplifier Units
RX9d amplifier is based on a modern, high performance D class topology.
This topology provides high efficiency, low heat generation and large output power At the same time, the high switching frequency of the output stage (450 kHz) provides sound quality comparable with the best analog amplifiers.
Analog inputs
The amplifier is equipped with four balanced analog inputs (XLR female).
The use of balanced inputs provides for an essential reduction of the environment­induced hum and noise interference with long input connecting cables.
For DSP processing, the analog signal is converted to digital using four 24-bit A/D converters, operating at 96 kHz. The dynamic range of A/D and D/A converters is 120 dB.
AES inputs
Inputs of channels 1 and 2 can be switched to digital input mode.
A digital AES/EBU two-channel audio signal can be applied to each input. Sound
signals can be sent to an amplifier from a digital mixing console or other device, that generates a digital audio signal AES/EBU (AES3). The AES/EBU inputs have balanced transformers and are protected against static electricity. Built-in sample rate converters support a wide range of input formats (16-24 bit / 44.1-192 kHz), converting any of them into internal format 24bit / 96kHz.
ETHERNET connectors
Two equivalent ports for connection to the ETHERNET network.
Provide the ability to configure and remotely control the amplifier over a network, using the NetControl software. The built-in router allows you to connect multiple amplifiers in
chain.
Line Outputs
Four XLR connectors (male).
Provide the possibility of parallel connection of several amplifiers, using standard signal cables.
When analog input signal is used, the line outputs are connected in parallel to the corresponding line inputs. When the digital input signal is used, the outputs are connected to the corresponding inputs via buffer amplifiers.
DSP engine
The amplifier is equipped with a flexible and powerful high-end DSP from DFM audio, Germany.
The close integration of processing and amplification allows the DSP to monitor and better respond to amplifier behavior, making dynamics processing far more accurate and effective than that typically achieved with separate components. The onboard DSP offers four channels of crossover filters, parametric EQ, FIR filter and alignment delay – everything needed to optimize a loudspeaker system.
Flexibly configurable RMS and PEAK limiters in each channel ensure reliable loudspeakers overload protection.
DSP settings control is performed via ETHERNET, using personal computer with the installed NetControl software.
For use in large installations, the processor has the tools for group control of many amplifiers simultaneously. The amplifier can be supplied with pre-formed library of passive speakers.
Software is designed for group control of a large number of amplifiers simultaneously. The program provides the ability to create virtual systems, which can be automatically merging with real amplifiers.
It is based on the work with Speaker and Preset libraries. The amplifier can be supplied with pre-installed Speaker libraries. Also, the user can update the Speaker library or create his own library. When creating a sound system, the user simply selects the desired type of loudspeaker from the library.
The NetControl installation package and user manual can be downloaded from parkaudio.ua (’’Downloads’’ section on the RX9d amplifier page).
User Interface
LCD display, LED indicators and controls (encoder and 4 buttons with illumination).
LED indicators on the front panel shows a signal presence, limiters activation and the overload of each amplifier channel. Encoder, LCD and buttons provide local access to navigation and DSP control.
Removable Power Cord
NEUTRIK powerCON 20A.
This feature is provided for convenience of transportation and rack mounting.
4
Loading...