Paris Business Products 44B1100, 44V0000 User Manual

PRONEBTM COMPRESSOR
INSTRUCTIONS FOR USE
ON
OFF
AIR
PRONEB
COMPRESSOR NEBULIZER
AC
COMPRESSOR
FILTER
!
WARNING / AVERTISSEMENT / ADVERTENCIA :
U.S. Federal law restricts this device to sale by or on the order of a physician. Read all warnings and instructions before use. Improper use can result in serious or fatal illness or injury. This product contains dry natural rubber.
La loi fédérale américaine exige que cet appareil soit vendu sur recommandation ou prescription médicale. Lire tous les avertissements et toutes les instructions avant l’emploi. L’usage inapproprié de cet appareil peut entraîner une maladie ou blessure grave ou même mortelle. Ce produit contient du caoutchouc naturel sec.
La Ley Federal de Los Estados Unidos de Norteamérica (USA) permite la venta de este producto solo bajo prescripción medica. Lea todas las advertencias e instrucciones antes de usarse. El manejo inapropiado podría resultar en perjuicio del paciente, su enfermedad o hasta llegar a ser fatal. Este producto contiene goma natural seca.
ENGLISH 6
ILLUSTRATIONS
Before reading these Instructions For Use, open this page to view the illustrations.
When reading Section IV on Set-Up, the illustrations on the left inside flap will
match the illustrations in the text. These illustrations will be helpful to you as
they are referenced throughout these Instructions For Use.
FRANÇAIS 11
ILLUSTRATIONS
Avant de lire ce guide d’utilisation, ouvrir cette page pour révéler les illustrations.
Les illustrations figurant sur le rabat intérieur gauche correspondent au texte de
la Section IV — préparation. Étant donné qu’on s’y reporte dans tout le guide
d’utilisation, ces illustrations seront utiles à l’utilisateur.
ESPAÑOL 16
ILUSTRACIÓNES
Antes de leer estas “Instrucciones Para El Uso” del equipo, abra esta página
con doblez. De esa manera cuando lea la sección IV de montaje, los dibujos
de la izquierda del doblez de la página coincidirán con el texto. Estas
ilustraciones serán de ayuda para usted, como referencia, a través de estas
Instrucciones Para El Uso.
2
A
ON
OFF
PRONEB
AIR
COMPRESSOR NEBULIZER
FILTER
B
C
D
F
ON
OFF
PRONEB
AIR
COMPRESSOR NEBULIZER
FILTER
E
G
ON
OFF
PRONEB
AIR
COMPRESSOR NEBULIZER
FILTER
ON
OFF
PRONEB
AIR
COMPRESSOR NEBULIZER
FILTER
ENGLISH
I. FEATURES, FUNCTIONS AND SPECIFICATIONS
(1) PRONEB Compressor (2) On/Off Switch (3) Air Outlet (4) Air Filter
SPECIFICATIONS OF COMPRESSOR: Weight: 4.2 lbs. (1.9 Kg) Dimensions: 3.75" x 6.5" x 8.25" (9.5 x 16.5 x 20.9cm) Electrical Requirements: 120V AC, 60Hz, 1.3 A or 220-240VAC, 50/60Hz Ambient Temperature Range: 10° C - 40° C (50° F - 104° F) Power Wattage: 65W @ 11 psi
(5) Nebulizer Holder (6) Power Cord Socket (7) Three Prong Power Cord (8) Nebulizer Stand*
FRANÇAIS
I. CARACTÉRISTIQUES, FONCTIONS ET SPÉCIFICATIONS
(1) Compresseur PRONEB (2) Interrupteur MARCHE/ARRÊT (ON/OFF) (3) Sortie d’air (4) Filtre à air
DONNÉES TECHNIQUES DU COMPRESSEUR: Poids: 1.9 kg (4.2 lb) Dimensions: 9.5 x 16.5 x 20.9 cm (3.75 x 6.5 x 8.25 po) Alimentation: Température ambiante: 10 à 40 oC, (50 à 104 oF) Puissance en watts: 65 W @ 16 lb/po2
120 V CA, 60Hz, 1.3 A ou 220-240 V CA, 50/60 Hz
(5) Support du nébuliseur (6) Raccord (7) Cordon d’alimentation avec fiche
à 3 broches
(8) Support du nébuliseur
ESPAÑOL
I. CARACTERÍSTICAS Y FUNCIONES
(1) Compresor PRONEB (2) Interruptor ON/OFF (3) Salida De Aire (4) Filtro De Aire
ESPECIFICACIONES DEL COMPRESOR: Peso: 4.2 lbs. (1.9 Kg) Dimensiones: 3.75” x 6.5” x 8.25” (9.5 x 16.5 x 21.0 cm) Requerimiento Eléctrico: 120VAC, 60Hz, 1.3A o 220-240VAC, 50/60Hz Rango De Temperatura Ambiental: 50° F - 104° F (10° C - 40° C)
Consumo De Potencia En Watts: 65W @ 11 psi
4
(5) Cavidad Para Nebulizador (6) Enchufe (7) Cordón Eléctrico (8) Soporte De Nebulizador
(1)
(2)
(3)
ON
OFF
PRONEB
AIR
COMPRESSOR NEBULIZER
(4)
(5)
(6)
(7)
FILTER
(8)
*Only the 5 year PRONEB with PARI LC PLUS (Part #37F81-LC+) includes a Nebulizer Stand.
Seul le compresseur PRONEB avec le nébuliseur PARI LC PLUS (pièce no 37F81-LC+), appuyé d’une garantie de 5 ans, est offert avec un support.
El Soporte De Nebulizador se incluye solamente en el PRONEB con PARI LC PLUS de 5 años de garantía (Código No. 37F81­LC+).
Actual Size
5
ENGLISH
I. SAFETY PRECAUTIONS
IMPORTANT SAFEGUARDS
When using electrical and medical products, especially when children are present, basic safety precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING
!
DANGER
To reduce the risk of serious or fatal injury from electrocution:
1. Do not use or store product where it can fall or be pulled into a bathtub, sink, water, or other liquid. Do not place in or drop into water or other liquid. Do not use while bathing.
2. Do not reach for a product that has fallen into water or other liquid. Unplug immediately.
3. Always unplug this product immediately after using (UL guidelines 1431).
!
WARNING
To reduce the risk of serious or fatal injury from electrocution, fire or burns and to reduce the risk of damage to the unit and malfunction:
1. Before use, check the specification plate on the bottom of the PRONEB compressor to ensure that the voltage and current indicated on the unit correspond to the voltage and current available.
2. Connect this product to a properly grounded outlet only. See Grounding Instructions on page 4.
3. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or if it has been exposed to any liquids inside the case. Return the product to an authorized PARI Service Center for examination and repair.
4. Keep all electrical cords away from heated surfaces. Do not overload wall outlets or extension cords.
5. Never block the air openings of this product or place it on a soft surface, such as a bed or couch, where the air openings may be blocked. Keep the air openings free of lint, hair, and similar substances. Blockage could cause excessive heat build-up. A product should never be left unattended when plugged in.
6. Never drop or insert any object into any openings.
7. Be sure the PRONEB is unplugged prior to cleaning.
8. Do not operate outdoors or where Oxygen is being administered in a closed environment such as inside an oxygen tent.
9. Do not open or disassemble the PRONEB Compressor. Refer all servicing to an authorized PARI Service Center.
!
WARNING
To reduce the risk of serious or fatal injury and improper treatment:
1. Use the product only for its intended use as described in these Instructions For Use. Use only when prescribed by a physician and with the prescribed medication.
2. Do not use nebulizers, tubing or other attachments not recommended by the manufacturer.
3. Close supervision is necessary when this product is used by or near the physically or mentally impaired or children. Never use while sleeping or drowsy.
SAVE THESE INSTRUCTIONS
6
ENGLISH
GROUNDING INSTRUCTIONS
This product should be grounded when used. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
!
DANGER
Improper use of the grounding plug can result in a risk of electric shock.
If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.
Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the product is properly grounded.
This product is for use on a nominal 120 V circuit, and has a grounding plug that looks like the plug illustrated in sketch A. A temporary adapter, which looks like the adapter illustrated in sketches B and C, may be used to connect this plug to a 2-pole receptacle (sketch B) if a properly grounded outlet is not available. The temporary adapter should be used only until a qualified electrician can install a properly grounded outlet (sketch A). The green colored rigid ear, lug, and the like extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover.
If it is necessary to use an extension cord, use only a 3-wire extension cord that has a three-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product. Replace or repair a damaged cord.
Whenever the adapter is used, it must be held in place by a metal screw.
GROUNDED OUTLET
GROUNDING PIN
(A)
GROUNDING METHODS
GROUNDED OUTLET BOX
(B)
ADAPTER
METAL SCREW
TAB FOR
GROUNDING
SCREW
(C)
7
Loading...
+ 15 hidden pages