or after changing the cylinder tank may take up to
2-3 minutes in order for the gas to purge through
the feeder lines.
** WARNING **
Improper operation, installation, adjustment,
alteration, servicing or maintenance can cause
severe property damage and/or serious damage
and/or serious injury or death. Please read the
installation, operating and maintenance instructions thoroughly before installing, operating or
servicing this appliance.
TABLE OF CONTENTS
GENERAL DESCRIPTION.................................3-4
Establishing a burner ignition for the FIRST time or
after changing the cylinder tank may take up to 2-3
minutes in order for the gas to purge through the
feeder lines.
If stored indoors, detach and leave cylinder outdoors.
Keep this manual in your les for future reference.
Hotline hours: Mon. to Fri. 7:00am - 5:00pm ( P.S.T.)
** IMPORTANT NOTICE***
e-mail: parts@jrhome.com
GENERAL DESCRIPTION - 3
A patio/deck & garden heater of operation with LPG (Liquid Propane Gas). For connection/working pressure
information & lighting instructions, see the appliance data plate labels and this manual.
MAIN COMPONENTS
1. Cylinder base, 18’’ dia.
2. Tank housing
3. Main Post w/Flange
4. Post support bracket assembly
5. Base of control housing
6. Intake screen
7. Burner base
8. Emitter Flame screen
9. Reector Hood, 32’’ Dia.
10. Gas valve controller
11. Electronic push button ignitor
12. Gas inlet supply hose
13. Gas Regulator
** IMPORTANT NOTICE***
Establishing a burner ignition for the FIRST time or after changing the cylinder tank may take up to
2-3 minutes in order for the gas to purge through the feeder lines.
***NOTICE***
During the FIRST TIME use only
It is normal to experience a small amount of smoke coming from the reector hood. This is due to the
burn o of the protective coating applied during the manufacturing process.
GENERAL DESCRIPTION - 4
WARNING !
CONSTRUCTION CHARACTERISTICS
Color: Brushed matte nish on stainless steel models. (Powder coat nish on steel models)
Casings: Base material on Deluxe Models feature stainless steel. (Galvanized sheet metal on steel models)
The burner is controlled using a positive lock, on/o gas control valve. The gas supply is controlled from gas
cylinder valve. The burner & burner assembly components are constructed from stainless steel. Emission of
infrared heat is assisted by the aluminum reector hood.
SAFETY Feature : This appliance has built in ‘’gas cut o’’ switch that shuts o the gas supply to the heater
assembly head any time the Burner Unit is tilted beyond 18 degrees or burner ame is extinguished.
Technical Data
Operating pressure with gas : 11’’WC (water column) (2.75 Kpa)
Inlet gas supply pressure : Min. 5 psi, Max. – 150 psi
Max. Heat rating : BTU 46,000
Low setting rating : BTU 17,000
Radiant Heat Range : 14 ft. To 16 ft. Diameter
Fuel Type : Liquid Propane Gas
Cylinder Size : Standard Industry 20 lb. Cylinder (5 gal. Cylinder capacity)
Consumption Rate : Approx. 10 hrs. at highest setting
Gross Weight : 63 lbs.
Certications : CSA
Gas Pressure Main Orice
Water Column Diameter in mm
11’’ (2.75 Kpa) 1.8
MADE IN CHINA
** WARNING **
Improper operation, installation, adjustment, alteration, servicing or maintenance can cause severe property damage and/or serious damage
and/or serious injury or death. Please read the
installation, operating and maintenance instructions thoroughly before installing, operating or
servicing this appliance.
GENERAL DESCRIPTION - 5
PRECAUTIONS – SAFETY FIRST!PLEASE READ THE FOLLOWING SAFETY RULES
Do not• use this space heater in an explosive atmosphere. Keep heater away from areas where gasoline or
other ammable liquids or vapors are strored.
Prior to use, check for damaged parts such as hoses, regulators, pilot, or burner.•Do not• attempt to alter unit in any manner. (EXAMPLE : Using the heater without the top canopy reector or
radiant screen.) Do not shorten the burner post assembly.
Heater must always be placed on a stable, solid level surface.•
Always maintain proper clearance to combustible materials. (Top : 36’’, sides : 24’’)•
Always ensure there is ample fresh air ventilation. For outdoor use ONLY.•
Never replace or substitute the regulator with any regulator other than an original factory supplied replace-•
ment or UL listed regulator.
Do not •clean heater with cleaners that are combustible or corrosive.
Do not• paint radiant screen, control panel, or top canopy reector.
All leak tests should be done with a soapy solution. NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS.•
The LP tank should be completely turned o at the cylinder valve when the heater is not in use.•
The LP regulator/hose assembly shall be kept completely inside cylinder housing. •
Children and adults should be aware fo the hazards of high surface temperatures and should use extreme cau-•
tion and keep proper distance away from main heater unit to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the area of the heater.•
Clothing or other ammable materials should not be hung from the heater, or placed on or near the heater.•
Any guard or other protective device removed for servicing the heatert must be replaced prior to operating •
the heater.
Installation and repair should be done by a qualied service person. The heater should be inspected before •
use and at least annually by a qualied service person. More frequent cleaning may be required. It is imperative that control compartment, burner and air circulation passageways of the heater be kept clean & clear of
debris, insects, spider webs, etc.
Keep the appliance area clear and free of combustion materials, gasoline and other ammable vapors and •
liquids.
Do not obstruct the ow of combustion and ventilation air.•
Keep the ventilation opening of the cylinder housing enclosure free and clear of debris.•
Save these instructions! Retain in a safe place for future reference. •
At least once a year, the unit should be inspected for the presence of spiders, spider webs, or other insects.
The burner area is a common spider haven and can damage the heater and render it unsafe for use.
Check the heater immediatly if any of the following exists :
1. The smell of gas in conjunction with extreme yellow tipping of the burner ames.
2. The heater does not reach maximum temperature.
3. The burner makes a popping noise during use (a slight popping noise is normal when the burner is extinguished).
** THINK SAFETY **
After appliance shut down.
Do NOT touch or move unit for at least 30 minutes. This allows for proper cooling of heater components.
Loading...
+ 10 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.