Model no. KLD7001S, KLD7001SS
Item no. PH-F-121-BK MO, PH-F-121-SS MO
FLAME HEATER
PATIO HEATER INSTRUCTION MANUAL
WARNING
!
HAZARDOUS FIRE OR EXPLOSION MAY RESULT IF
INSTRUCTIONS ARE IGNORED.
It is the consumer’s responsibility to see that the
patio heater is properly assembled, installed, and
taken care of. Failure to follow instructions in this
manual could result in bodily injury and/or
property damage.
PRECAUTIONS
!
5000199
Conforms to ANSI
STD Z83.26a-2008
Certified to CSA
STD 2.37a-2008
vapours and liquids in the vicinity of this or any
other appliance.
•Any LP cylinder not connected for use shall not be
stored in the vicinity of this or any other appliance
FOR YOUR SAFETY IF YOU SMELL GAS:
1.T
3.Do not operate any electrical appliances
4.Ventilate the area.
5.Check for leaks as detailed in this manual.
6.If odour persists, contact your dealer or gas
supplier immediately.
For customer service, parts
or war ranty issues:
Call 1-800-561-5550
or e-mail customercare@jrhome.com
FOR OUTDFOOR USE ONLY | USES PROPANE LPG ONLY
PLEASE READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY
RETAIN THIS MANUAL FOR REFERENCE
!
DANGER
CARBON MONOXIDE HAZARD
This appliance can produce carbon
monoxide which has no odor.
Using it in an enclosed space can kill
you. Never use this appliance in a
enclosed space such as a camper, tent,
car or home.
WARNING : Improper installation, adjustment
alteration, services or maintenance can cause
injury, death or property damage. Read the
installation operating and maintenance
instructions thoroughly before installing
or servicing this equipment.
WARNING :
FOR OUTDOOR USE ONLY.
Cylinders to be used must be constructed and
Storage indoors is permissible only if the cylinder
is removed
The unit should be secured or moved indoors
if winds exceed 19.5mph.
Note:
Use the 20lb. LPG tank, but it is not supplied.
Use for CSA regulator with 0.6m gas house.
This regulator is set for an outlet pressure of 11”
water column.
TOOLS REQUIRED
Phillips head screwdriver
Leak detection solution
For questions, replacement parts, service help
or other assistance please call :
1-800-561-5550
or email customercare@jrhome.com
PRECAUTIONS
PLEASE READ THE FOLLOWING SAFETY RULES
WARNING
This appliance must only be used outdoors
Using this product in an enclosed area may cause injury, death or property damage.
Read instructions before use.
This appliance must be installed in accordance with your local area’s regulations and bylaws
• Disconnect LPG bottle before moving the heater
• Before use, check the hose
• Disconnect the LPG cylinder before moving the heater.
• Do not attempt to alter this unit in any manner
• This appliance shall not be used in basements or below ground level.
• Never replace or substitute the regulator, use only one that is suitable for both appliance category
and normal pressure of gas.
• Do not clean the heater with cleaners that are combustible or corrosive
WARNING
• Do not use heater when it is raining and always be careful to not let any liquids splash onto
the glass tube when the heater is working
• Keep children away from the heater and be careful not to knock down the heater, which will
cause the glass to break and may cause injury.
• Do not move the appliance while operating
At least once a year the unit should be inspected for spiders, spider webs or other insects
Check the heater immediately if any of the following problems exist:
1. The smell of gas
2. The heater does not reach temperature
3. The burner makes a popping noise during use (a slight popping noise is normal when the
burner is extinguished after use)
IIf the smell persists, contact the dealer or
gas supplier immediately.
• The hose with regulator assembly shall be stored in a safe place to avoid any accidental damage.
• Children and adults should be aware of the high surface temperature hazard, and should keep a
• Young children should be carefully supervised when they are in the working area of the heater.
the heater.
• Do not obstruct the ventilation holes of the cylinder housing.
• In case of violent wind particular attention must be taken against tilting of the appliance.
• Storage of the heater indoors is permitted only if the cylinder is disconnected and
removed from the appliance.
• Do not store a spare LP-gas cylinder under or near this heater.
APPLIANCE STAND AND LOCATION
• The appliance is for outdoor use only.
• Do not use it indoors or in enclosed areas.
• Always ensure that adequate fresh air ventilation is provided
• Always maintain proper clearance from combustible materials
(i.e. / top: 800mm and sides: 650mm minimum)
• Never operate appliance in an explosive atmosphere like in areas
DIAGRAMMATICAL REPRESENTATIONS OF OUTDOOR AREAS
Warning
LEAK TESTING
WARNING
do not smoke
while leak testing
Gas connections on the appliance are leak tested at the factory prior to shipment. Possible mishandling of the
appliance during the shipment might contribute to product integrity as a whole. A complete gas leakage test
must be performed again at the installation site.
Please follow the procedure below for leakage test.
1. Make a soap solution of one part liquid detergent and one part water. The soap solution can be applied with
a spray bottle, brush or rag. Soap bubbles will appear where the leak is present.
2. Make sure the control tap is in the <<OFF>> position (full disk = • ) on the control panel
3. Turn on the gas supply and check for bubbles on the hoses and connections. If the solution starts to bubble
that means that a leak is present.
to see if it still continues to leak.
5. Never leak test while smoking
INSTALLATION
Important Safety Rules:
This appliance is for OUTDOOR USE ONLY
1. This appliance shall not be installed or used indoors, in buildings, garages or any
other enclosed area
2. DO NOT place articles on or against this appliance
3.
4. Children and adults should be aware to the hazards of high surface temperatures, burns and clothing ignition
5. Children should be carefully supervised when they are in the area of the appliance
6.
7.
8. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION
9.
may be required as necessary. It is imperative that control compartments, burners and
circulating air passages of the heater and light be kept clean
Part list
M5x10
84x
M6x12
7x
A
BC
M6
7x
D
Bolt
3x
E
wing nut
3x
Part no Qty DescriptionPart no Qty Description
Reflector
upper plate
glass tube
protection guard
upper leg
rubber ring
middle plate
hook panel
burner
lower leg
side panel
bottom plate
wheels
front panel
stability ring
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
1
2
3
4
5
9
6
8
10
11
12
13
14
7
3
1
1
1
1
1
41
41
1
1
1
7
A
M6x12
B
M5x10
C
D
E
M6
Bolt
regulator and hose
4
84
1
7
3
3 Wing nut
4
15
16
- 5 -
Loading...
+ 12 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.