Paradyne Hotwire 8776 Installation Instructions Manual

Page 1
Hotwirer 8776 TDM SDSL Termination Unit with G.703 Interface
Installation Instructions
Document Number 8776-A2-GZ40-40
February 2001
Complete documentation for this product is available at www.paradyne.com. Select Library Technical Manuals Hotwire DSL & MVL Systems.
Select the following document:
8776-A2-GB20
Hotwire 8776 TDM SDSL Termination Unit, with G.703 Interface, User’s Guide
To order a paper copy of a Paradyne document:
H Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396) H Outside the U.S.A., call 1-727-530-8623
Hotwire 8776 TDM SDSL Termination Unit
The Hotwirer 8776 Termination Unit is a circuit card assembly that contains four Time Division Multiplexer Symmetric Digital Subscriber Line (TDM SDSL) ports and a G.703 interface. When the unit is used in a Hotwire 8600 or 8800 Series Digital Subscriber Line Access Multiplexer (DSLAM) chassis, it transports up to 2048 kbps signals over traditional twisted-pair telephone wiring.
!
HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static control precautions to prevent damage to equipment. If you are not sure of the
496-15104
proper static control precautions, contact your nearest sales or service representative.
8776-A2-GZ40-40
February 2001
1
Page 2
Installation Overview
Installation and configuration of the Hotwire 8776 TDM SDSL Termination Unit consists of:
H Installing the unit in the DSLAM. H Connecting to the DTE. H Connecting to an MDF. H Providing initial unit identity information or changing existing identity
information.
H Configuring your unit using the Configuration Edit menus.
Before you install the unit, read the Important Safety Instructions on page 18. Be sure to register your warranty at www.paradyne.com/warranty.
Planning the Installation
Review the following list to help plan for the installation.
- Obtain the applicable cables; refer to Cables You Need, below.
- Make sure the Hotwire DSLAM chassis is installed and power is supplied to
the chassis.
Cables You Need
- After the Hotwire TDM SDSL Termination Unit is installed, there are configuration procedures that must be performed before you can begin to use the unit. Refer to the Hotwire 8776 TDM SDSL Unit, with G.703 Interface, Users Guide for more detailed configuration procedures.
The following standard cables are used with this product.
For the network connection:
H Plug-ended Telco 50-pin cable for connection from the Hotwire 8600 Series
DSLAM LINE port or one of the Hotwire 8800 Series DSLAM LINES ports to the Main Distribution Frame (MDF) or other demarcation point.
For the DTE connection:
H The 50-position plug-to-four 8-position unkeyed modular jacks, such as
Paradyne Feature No. 8700-F1-505.
For further information refer to Connector Pin Assignments in the User’s Guide, and the appropriate DSLAM installation document.
2
February 2001
8776-A2-GZ40-40
Page 3
Installing TDM SDSL Cards
A Hotwire 8776 TDM SDSL Termination Unit can be installed, removed, and replaced from a the DSLAM chassis without disrupting service to the other cards in the chassis.
" Procedure
To install the unit:
1. Determine in which slot the unit will be installed. Verify that cards in adjacent slots have been fastened.
2. Remove the filler plate from the installation slot.
3. Insert the unit:
For a Hotwire 8600 Series DSLAM chassis – Hold the Hotwire 8776
TDM SDSL Termination Unit horizontally, with the component side facing up, and insert it into the left and right card guides.
For a Hotwire 8800 Series DSLAM chassis – Hold the Hotwire 8776
TDM SDSL Termination Unit vertically, with the component side facing right, and insert it into the top and bottom card guides.
4. Slide the unit into the slot until the power and network connectors seat firmly in the mating connectors on the backplane.
CAUTION:
Do not force the unit into the slot. This could damage the backplane connectors. If the card does not seat properly, remove the card and reinstall it. If it still does not seat properly, call your service representative.
The unit performs a power-on self-test. All of the LEDs turn ON and OFF briefly. When the self-test is completed successfully, the SYSTEM OK LED begins to pulse.
5. If the LED is not pulsing, refer to Messages and Troubleshooting in the User’s Guide.
6. Secure the unit by fastening the screws at each end of the faceplate.
8776-A2-GZ40-40
February 2001
3
Page 4
Connecting to the DTE
Connection to the four ports of the Hotwire 8776 TDM SDSL Termination Unit is through the 50-pin interface connector on its faceplate. Refer to Connector Pin Assignments in the User’s Guide.
" Procedure
To connect the Hotwire 8776 TDM SDSL Termination Unit to your DTE:
1. Connect the 50-position connector of the cable to the connector on the faceplate of the unit. Align one end of the cable connector with the card connector, then push on the cable connector until it seats.
The end of the cable connector has a release button. To remove the connector, press the release button and pull the connector away from the card.
2. Feed the cable through the Cable Guide if it is in use. When all cables are installed, anchor them with cable ties to the rack, DSLAM, or Cable Guide.
3. Connect the four terminating connectors to your DTE.
Connecting to an MDF
You can connect the Hotwire DSLAM chassis containing the Hotwire 8776 TDM SDSL Termination Unit to an MDF or other demarcation point. Do not connect it to a POTS splitter.
" Procedure
To connect the Hotwire DSLAM chassis containing the Hotwire 8776 TDM SDSL Termination Unit to an MDF:
1. Plug the Telco 50-pin cable into the appropriate LINE port on the chassis.
2. Replace the longer Telco cable captive screw with a shorter connector captive screw, which is provided with the Hotwire DSLAM chassis.
3. Insert a cable tie (provided with Hotwire DSLAM chassis) through the tie mount to hold the Telco 50-pin connector in place. If more than one Telco cable is being connected, span the two or three connectors.
4. Make sure the other end is connected to the appropriate MDF or demarcation point.
Refer to Connector Pin Assignments in the Users Guide for pinouts.
NOTE:
If you are connecting the Telco 25-pair, 50-pin cable to an MDF, a converter may be necessary for terminating the other end of the cable on a punchdown block before cross-connecting to an MDF.
4
February 2001
8776-A2-GZ40-40
Page 5
Front Panel LEDs
The following table describes the meaning and states of the LEDs on the Hotwire 8776 TDM SDSL Termination Unit’s faceplate.
S
Y
STE
M
G
D
.703
SL P
OK Alrm Test
1 2 3 4
O
1 2 3 4
R
T
Type
SYSTEM
LED LED is . . .* Indicating . . .
OK (Green)
Alrm (Amber)
Test (Amber)
On Off Slow Cycling
Pulsing On
Off On
Slow cycling Off
Unit failure; system processing has stopped. No power to card. Unit is in minimum mode and a download is
required. Normal operation.
Unit failure, or Power-On Self-Test (POST) has failed.
No alarms. Loopback test or 51 1 test pattern in progress.
POST in progress. No tests.
TDM
SDSL
8776
00-16041-02
G.703 1, 2, 3, 4
(Green)
DSL PORT 1, 2, 3, 4
(Green)
On
Slow cycling Fast cycling Off
On Slow cycling Fast cycling Off
Recoverable signal present on the G.703 network.
Remote Alarm Indication (RAI) present. An OOF, LOF, EER, or AIS condition exists. No signal on the port.
DSL link is up. DSL training in progress. OOF condition. DSL link is down.
* Slow Cycling: LED turns off and on in equal duration once per second.
Fast Cycling: LED turns off and on in equal duration 5 times per second. Pulsing: LED turns off momentarily once per second.
8776-A2-GZ40-40
February 2001
5
Page 6
Logging In to the Hotwire DSLAM
You can log in to the Hotwire DSLAM system using either a local VT100­compatible terminal or a remote Telnet connection.
After you enter your user ID and password, the system displays the Hotwire Chassis Main Menu. See your Management Communications Controller (MCC) documentation for information about selecting the unit from the MCC card selection screen.
Asynchronous Terminal Interface Menu
The following illustration shows the paths to the Hotwire 8776 TDM SDSL Termination Units various ATI screens.
Main
System and
Test Status
Performance
Network
Error
Statistics
Performance
Statistics
Network
Statistics
Status Test
Display
Identity
LEDs
Current
Network
Performance
G.703
Statistics
Network &
G.703 T ests
Device
Tests
Network G.703 Copy
Configuration
Abort All
Tests
Telnet
Session
Configuration Control
Current
Ports
General SNMP
Management
Change
Identity
Configuration
System Options
Download
Administer
Logins
Loader
Configuration
Management
Communication
SNMP NMS
Security
Code
Default
Factory
Apply
Download
and
SNMP
Traps
Reset
AutoRate
Reset
Device
01-16044-03
6
February 2001
8776-A2-GZ40-40
Page 7
Entering Identity Information
After accessing your unit for the first time, use the Change Identity screen to determine SNMP administrative system information that will be displayed on the Identity screen of the Status branch. To access the Card Identity screen, follow this menu selection sequence:
Main Menu →Control →Change Identity
Configuring the Unit
Configuration option settings determine how the unit operates. Use the Configuration branch of the Hotwire 8776 TDM SDSL Termination Units menu to display or change configuration option settings.
If the factory default settings do not support your networks configuration, customize the configuration options for your application.
8776-A2-GZ40-40
February 2001
7
Page 8
Accessing and Displaying Configuration Options
To display the configuration options, you must first load a configuration option set into the edit area.
To load a configuration option set into the configuration edit area, follow this menu selection sequence:
Main Menu Configuration (Load Configuration From)
main/configuration Hotwire Slot: 4 Model: 8776
LOAD CONFIGURATION FROM:
Current Configuration Configuration Loader Default Factory Configuration
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Ctrl-a to access these functions, ESC for previous menu M
ainMenu Exit
Make a selection by placing the cursor at your choice and pressing Enter.
If you select . . .
Current Configuration
Configuration Loader
Default Factory Configuration
Then . . .
The selected configuration option set is loaded and the Configuration Edit/Display menu screen appears.
The Configuration Loader screen is displayed allowing you to upload or download configurations from a TFTP server.
The selected configuration option set is loaded and the Configuration Edit/Display menu screen appears.
8
February 2001
8776-A2-GZ40-40
Page 9
Configuration Edit/Display
The Configuration Edit/Display screen is displayed when the current, customer, or default configuration is loaded and allows groups of configuration options to be displayed. To access the Configuration Edit/Display screen, follow this menu selection sequence:
Main Menu →Configuration →Current Configuration
or –
Main Menu →Configuration →Default Factory Configuration
main/config/edit Hotwire Slot: 4 Model: 8776
CONFIGURATION EDIT/DISPLAY
Network G.703 Copy Ports System Options Management and Communication
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu M
ave
S
ainMenu Exit
Select . . . To Access the . . . To Configure the . . .
Network Network Interface Options, Table 1 DSL network interface
Ports 1–4. G.703 G.703 Interface Options, Table 2 G.703 interface. Copy Ports Copy Ports Options, Table 3 DSL network and G.703
interface ports by copying
options from port to port. System
Options Management
and Communication
System Options, Table 4 General system options of
the unit.
H Telnet Session Options, Table 5 H General SNMP Management
Options, Table 6
H SNMP NMS Security Options,
Management support of the
unit through SNMP and
Telnet.
Table 7
H SNMP Traps Options, Table 8
NOTE:
The SNMP NMS Security Options screen is not available in IP Conservative mode.
8776-A2-GZ40-40
February 2001
9
Page 10
Table 1. Network Interface Options
Margin Threshold Possible Settings: –5db, –4db, –3db, –2db, –1db, 0db, 1db, 2db, 3db, 4db, 5db, 6db,
7db, 8db, 9db, 10db
Default Setting: 0db Determines the level, expressed in decibels, at which a signal-to-noise margin condition
is recognized.
Excessive Error Rate Threshold
Possible Settings: 1E–4, 1E–5, 1E–6, 1E–7, 1E–8, 1E–9 Default Setting: 1E–6
Determines the error rate at which an excessive error rate (EER) condition is recognized. The rate is the ratio of the number of CRC errors to the number of bits received in a certain period.
AutoRate
Possible Settings: Enable, Disable Default Setting: Disable
Determines whether the unit automatically adjusts to the best line rate for conditions, or is fixed at the rate in the DSL Line Rate field. The automatically set rate cannot exceed DSL Line Rate.
H AutoRate is only available when the unit is configured as an LTU.
DSL Line Rate
Possible Settings: 400, 528, 784, 1040, 1552, 2064 Default Setting: 2064
Determines the fixed line rate of the L TU when AutoRate is disabled, and the maximum rate to which the unit can be set if AutoRate is enabled.
H DSL Line Rate is only available when the unit is configured as an LTU.
Peer IP Address
Possible Settings: 001.000.000.000 – 223.255.255.255, Clear Default Setting: 000.000.000.000
Specifies the peer IP address providing the remote management link on the DSL loop. The Peer IP Address is only available when the unit is configured as an L TU.
H Peer IP Address is only available when the unit is configured as an LTU and the
unit is not running in IP Conservative mode.
Circuit Identifier
Possible Settings: [ASCII text] Default Setting: [blank]
Uniquely identifies the circuit number of the transmission vendors DSL line for troubleshooting purposes.
10
February 2001
8776-A2-GZ40-40
Page 11
Table 2. G.703 Interface Options
Port Status
Possible Settings: Enable, Disable Default Setting: Enable
Determines whether the port can be configured and used.
Framing
Possible Settings: Framed, Unframed Default Setting: Framed
Determines whether the port can be configured and used.
Line Coding
Possible Settings: AMI, HDB3 Default Setting: HDB3
Specifies the line coding format to be used by the G.703 interface.
Line Framing
LTU Only. Possible Settings: CRC4, noCRC4 Default Setting: noCRC4
Specifies the framing format to be used by the G.703 interface.
H Line Framing is only available when the unit is configured as an LTU, AutoRate is
disabled, and the DSL Line rate is 2064 kbps. Otherwise the noCRC4 framing format is used. The NTU is automatically configured to match the framing format used by the L TU.
Time Slot 16
Possible Settings: Signaling, Data Default Setting: Signaling
Specifies whether the G.703 interface is used for voice or data.
Send (AIS) on Network Failure
Possible Settings: Enable, Disable Default Setting: Enable
Specifies the action taken on the signal transmitted to the G.703 when a valid signal cannot be recovered from the network interface (LOS or OOF).
Primary Clock Source
Possible Settings: Internal, G.703 Default Setting: Internal
Determines the primary clock source for the unit.
H Primary Clock Source is available only when the unit is configured as an LTU.
Secondary Clock Source
Possible Settings: Internal, G.703 Default Setting: Internal
Determines the secondary clock source for the unit.
H Secondary Clock Source is available only when the unit is configured as an LTU.
8776-A2-GZ40-40
February 2001
11
Page 12
Table 3. Copy Ports Options
From: Port n
Possible Settings: 1, 2, 3, 4 Default Setting: 1
Controls the source of the configuration options.
To: Port y
Possible Settings: 1, 2, 3, 4, All Default Setting: 2
Controls the target of the configuration options.
NOTE: Peer IP Address and Circuit Identifier are not copied.
Table 4. System Options
DSL Mode
Possible Settings: LTU, NTU Default Setting: LTU
Controls whether the unit is configured as a control unit or tributary unit.
NOTE: Changing this option will reset the card.
T est Timeout
Possible Settings: Enable, Disable Default Setting: Enable
Allows tests to end automatically . The feature should be enabled when the unit is remotely managed, so that control can be regained after a test is accidentally executed.
Test Duration (min)
Possible Settings: 1–120 Default Setting: 10
Number of minutes for a test to be active before automatically ending.
H Test Duration (min) option appears when Test Timeout is enabled.
G.703 Line T ermination
Possible Settings: 75 ohms, 120 ohms Default Setting: 120 ohms
Specifies the impedance of the G.703 interface
12
February 2001
8776-A2-GZ40-40
Page 13
Table 5. Telnet Session Options
T elnet Session
Possible Settings: Enable, Disable Default Setting: Enable
Specifies if the unit will respond to a Telnet session request from a Telnet client on an interconnected IP network.
T elnet Login Required
Possible Settings: Enable, Disable Default Setting: Disable
Specifies whether a user ID and password are required to access to the A TI through a Telnet session. Login IDs are created with a password and access level.
Session Access Level
Possible Settings: Administrator, Operator Default Setting: Administrator
The Telnet session access level is interrelated with the access level of the Login ID.
Inactivity Timeout
Possible Settings: Enable, Disable Default Setting: Disable
Provides automatic logoff of a Telnet session.
Disconnect Time (Minutes)
Possible Settings: 1–60 Default Setting: 5
Number of minutes of inactivity before a Telnet session terminates automatically. Timeout is based on no keyboard activity.
H Disconnect Time (minutes) option appears when Inactivity Timeout is enabled.
8776-A2-GZ40-40
February 2001
13
Page 14
Table 6. General SNMP Management Options
SNMP Management
Possible Settings: Enable, Disable Default Setting: Disable
Enables or disables the SNMP management features.
Community Name 1
Possible Settings: [ASCII text], Public Default Text: Public
Identifies the name of the community allowed to access the units MIB. The community name must be supplied by an external SNMP manager when that manager attempts to access an object in the MIB.
Name 1 Access
Possible Settings: Read, Read/Write Default Setting: Read
Determines the access level for Community Name 1.
Community Name 2
Possible Settings: [ASCII text], Public Default Text: [null string]
Identifies the name of the second community allowed to access the units MIB. The community name must be supplied by an external SNMP manager when that manager attempts to access an object in the MIB.
Name 2 Access
Possible Settings: Read, Read/Write Default Setting: Read
Determines the access level for Community Name 2.
14
February 2001
8776-A2-GZ40-40
Page 15
Table 7. SNMP NMS Security Options
NMS IP Validation
Possible Settings: Enable, Disable Default Setting: Disable
Specifies whether security checking is performed on the IP address of SNMP management systems attempting to access the node.
Number of Managers
Possible Settings: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Default Setting: 1
Specifies the number of SNMP management systems that can send SNMP messages.
NMS n IP Address
Possible Settings: 001.000.000.000 – 223.255.255.255, Clear Default Setting: 000.000.000.000
Specifies the Internet Protocol address used to identify each SNMP manager.
Access Level
Possible Settings: Read, Read/Write Default Setting: Read
Determines the access level allowed for an authorized NMS when IP address validation is being performed.
8776-A2-GZ40-40
February 2001
15
Page 16
Table 8. SNMP Traps Options
SNMP Traps
Possible Settings: Enable, Disable Default Setting: Disable
Controls the generation of SNMP trap messages. The options for addresses and types of traps are located in this table.
Number of Trap Managers
Possible Settings: 1, 2, 3, 4, 5 Default Setting: 1
Sets the number of SNMP management systems that will receive SNMP traps.
H This field is not available when the unit is running in IP Conservative mode.
NMS n IP Address
Possible Settings: 001.000.000.000 – 223.255.255.255, Clear Default Setting: 000.000.000.000
Specifies the Internet Protocol address used to identify each SNMP trap manager.
H This field is not available when the unit is running in IP Conservative mode.
NMS n Destination
Possible Settings: IMC, DSL1, DSL2, DSL3, DSL4 Default Setting: IMC
Provides the network destination path of each trap manager.
H NMS n Destination is available only when the unit is configured as an NTU and not
running in IP Conservative mode. Disabled ports cannot be specified.
General Traps
Possible Settings: Disable, Warm, AuthFail, Both Default Setting: Both
Determines which SNMP traps are sent to each trap manager.
Enterprise Specific Traps
Possible Settings: Enable, Disable Default Setting: Disable
Determines if SNMP traps are generated for enterprise-specific events.
Link Traps
Possible Settings: Disable, Up, Down, Both Default Setting: Both
Determines if SNMP traps are generated for link up and link down for one of the communication interfaces.
Link Trap Interfaces
Possible Settings: Network, G.703, All Default Setting: All
Determines if the SNMP linkUp, SNMP linkDown, and interface-related enterpriseSpecific traps are generated for the network DSL interface and/or G.703 interface (DTE).
16
February 2001
8776-A2-GZ40-40
Page 17
Configuring AutoRate
The TDM SDSL AutoRate function is controlled from the Network Interface Options screen and allows you to enable or disable AutoRate. The AutoRate option is only available if the unit is configured as an LTU. To access the Network Interface screen, follow this menu selection sequence:
Main Menu →Configuration →Network
NOTE:
AutoRate is designed to find the best rate possible for your DSL loop conditions. After the DSL loop is up, units should be configured to run in fixed rate.
main/config/network Hotwire Slot 4 Model: 8776
NETWORK INTERFACE OPTIONS
Margin Threshold: –3db Excessive Error Rate Threshold: 1E–6 AutoRate Disable DSL Line Rate 528
Peer IP Address: 111.255.255.000 Clear
Circuit Identifier:
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu M
ave
S
ainMenu Exit
" Procedure
The AutoRate option is defaulted to Disable. To enable AutoRate:
1. Position the cursor in the AutoRate field and press the spacebar.
The AutoRate field toggles to Enable and the DSL Line Rate field displays.
2. Enter a DSL Line Rate and press Enter.
Your payload rate is set to a default value of 1984. Use Table 9, Fixed Rate Payload Rates and DSL Line Rates, to set your DSL Line Rate and Payload Rate according to whether you are configured for Voice (signaling) or Data.
Clear
8776-A2-GZ40-40
February 2001
17
Page 18
Table 9 provides the maximum payload rates achievable for each DSL line rate and the number of time slots required to achieve that payload rate depending on whether you are using signaling (time slots 0 and 16) or data only (time slot 0).
Table 9. Fixed Rate Payload Rates and DSL Line Rates
Voice Mode (G.703-to-G.703)
Maximum DSL Line Rate (kbps)
2064 1920 30 1984 31 1984 31 1552 1408 22 1472 23 1536 24 1040 896 14 960 15 1024 16
784 640 10 704 11 768 12 528 384 6 448 7 512 8 400 256 4 320 5 384 6
!
Important Safety Instructions
Payload
Rate (kbps)
1. Read and follow all warning notices and instructions marked on the product
or included in the manual.
2. Slots and openings in the cabinet are provided for ventilation. To ensure
reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.
Time Slots
Data Mode (G.703-to-G.703)
Maximum Payload Rate (kbps)
Time Slots
Data Mode (G.703-to-EIA-530)
Maximum Payload Rate (kbps)
Time Slots
18
3. Do not allow anything to rest on the power cord and do not locate the product
where persons will walk on the power cord.
4. Do not attempt to install or service this product yourself, as opening or
removing covers may expose you to dangerous high voltage points or other risks. Refer all installation and servicing to qualified service personnel.
5. General purpose cables are provided with this product. Special cables, which
may be required by the regulatory inspection authority for the installation site, are the responsibility of the customer.
6. When installed in the final configuration, the product must comply with the
applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance.
7. A rare phenomenon can create a voltage potential between the earth
grounds of two or more buildings. If products installed in separate buildings are interconnected, the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the products.
February 2001
8776-A2-GZ40-40
Page 19
EMI Notices
8. In addition, if the equipment is to be used with telecommunications circuits,
take the following precautions:
Never install telephone wiring during a lightning storm.Never install telephone jacks in wet locations unless the jack is
specifically designed for wet locations.
Never touch uninsulated telephone wires or terminals unless the
telephone line has been disconnected at the network interface.
Use caution when installing or modifying telephone lines.Avoid using a telephone (other than a cordless type) during an electrical
storm. There may be a remote risk of electric shock from lightning.
Do not use the telephone to report a gas leak in the vicinity of the leak.
!
UNITED STATES – EMI NOTICE:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation.
!
CANADA – EMI NOTICE:
This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du règlement sur le matérial brouilleur du Canada.
8776-A2-GZ40-40
February 2001
19
Page 20
Warranty, Sales, Service, and Training Information
Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:
H Internet: Visit the Paradyne World Wide Web site at www.paradyne.com.
(Be sure to register your warranty at www.paradyne.com/warranty.)
H Telephone: Call our automated system to receive current information by fax
or to speak with a company representative.
Within the U.S.A., call 1-800-870-2221Outside the U.S.A., call 1-727-530-2340
Document Feedback
We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.
Trademarks
Hotwire is a registered trademark of Paradyne Corporation. All other products and services mentioned herein are the trademarks, service marks, registered trademarks or registered service marks of their respective owners.
*8776-A2-GZ40-40*
*8776–A2–GZ40–40*
Copyright E 2001 Paradyne Corporation. Printed in U.S.A.
20
February 2001
8776-A2-GZ40-40