Paradyne Hotwire 8335, Hotwire 8355, Hotwire 8365, Hotwire 8375, Hotwire 8385 User Manual

Page 1
Hotwire
®
ATM Line Cards
Models 8335, 8355, 8365, 8375, and 8385
User’s Guide
Document No. 8335-A2-GB20-A0
March 2005
Page 2
A March 2005 8335-A2-GB20-A0
Copyright 2005 Paradyne Corporation. All rights reserved. Printed in U.S.A.
Notice
This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773.
Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes.
Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual.
Warranty, Sales, Service, and Training Information
Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:
Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at
www.paradyne.com/warranty.)
Telephone: Call our automated system to receive current information by fax or to speak with a company
representative.
— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A., call 1-727-530-2340
Document Feedback
We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.
Trademarks
Acculink, ADSL/R, Bitstorm, Comsphere, DSL the Easy Way, ETC, Etherloop, FrameSaver, GranDSLAM, GrandVIEW, Hotwire, the Hotwire logo, iMarc, Jetstream, MVL, NextEDGE, Net to Net Technologies, OpenLane, Paradyne, the Paradyne logo, Paradyne Credit Corp., the Paradyne Credit Corp. logo, Performance Wizard, ReachDSL, StormPort, TruePut are registered trademarks of Paradyne Corporation.
Connect to Success, Hotwire Connected, JetFusion, JetVision, MicroBurst, PacketSurfer, Quick Channel, Reverse Gateway, Spectrum Manager, and StormTracker are trademarks of Paradyne Corporation.
All other products or services mentioned herein are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners.
Regulatory and Safety Information
Refer to the appropriate Broadband Loop Carrier (BLC) installation guide for all regulatory notices and safety information.
Page 3
8335-A2-GB20-A0 March 2005 i
Contents
About This Guide
Document Purpose and Intended Audience . . . . . . . . . . . . . . . . . . . . v
Document Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Product-Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
1 About the ATM Line Cards
Hotwire ATM Line Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
ATM Line Card Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
DSL Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
ATM Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Endpoint Support Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Network Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
SNMP Management Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Management Information Base (MIB) Support . . . . . . . . . . . . . . . 1-5
SNMP Trap Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
2 Menus and Screens
Menu and Screen Formats. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Components of a Hotwire Screen . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Naming Conventions for Ports and Interfaces . . . . . . . . . . . . . . . . . . . 2-3
General Navigation Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Pop-Up Menu Navigation Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
User Login Screen (MCP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Quick Card Select Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Exiting from the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Manually Logging Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Automatically Logging Out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
3 Configuration
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Saving and Restoring Configuration Options . . . . . . . . . . . . . . . . . . . . 3-1
Entering Card Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Entering the Time and Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Page 4
Contents
ii March 2005 8335-A2-GB20-A0
Setting Spectrum Management (Models 8355, 8375, and 8385). . . . . 3-4
Other Functions of the Card Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Configuring the DSL Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
DSL Port Configuration – Model 8335 . . . . . . . . . . . . . . . . . . . . . . 3-8
DSL Port Configuration – Model 8355 . . . . . . . . . . . . . . . . . . . . . . 3-11
DSL Port Configuration – Model 8365 . . . . . . . . . . . . . . . . . . . . . . 3-16
DSL Port Configuration – Model 8375 . . . . . . . . . . . . . . . . . . . . . . 3-19
DSL Port Configuration – Model 8385 . . . . . . . . . . . . . . . . . . . . . . 3-24
Configuring the ATM Physical Layer (Models 8335, 8365, and 8385) . 3-28
Configuring ATM Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30
Configuring ATM Cross Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 3-32
Configuring ATM Traffic Profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-36
Clearing Cross Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-41
Configuring Rate Shaping (Models 8335, 8365, 8385) . . . . . . . . . . . . 3-42
Entering Service Node Configuration Information
(Models 8335, 8365, 8375, and 8385) . . . . . . . . . . . . . . . . . . . . . 3-43
Entering Service Node Management Configuration Information
(Models 8335 and 8385) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46
4 Monitoring
What to Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Viewing Card Status and Information. . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Viewing Physical Ports Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Monitoring ATM Activity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
Monitoring SN Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20
5 Diagnostics
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Self-Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
ATM Ping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
ATM Ping Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-13
Loopback Test (Model 8385 Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15
6 Maintenance Procedures
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
Clearing NVRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Uploading and Downloading a Configuration . . . . . . . . . . . . . . . . . . . . 6-3
Page 5
Contents
8335-A2-GB20-A0 March 2005
iii
Uploading a Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
Downloading a Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
Configuration Loader Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
Resetting the Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
Downloading Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
A SNMP Traps
Trap Managers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
SNMP Traps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
B Connector Pin Assignments
Model 8820 BLC Telco Connector Pinouts . . . . . . . . . . . . . . . . . . . . . B-1
Model 8620 BLC Telco Connector Pinouts . . . . . . . . . . . . . . . . . . . . . B-2
C Technical Specifications
Index
Page 6
Contents
iv March 2005 8335-A2-GB20-A0
Page 7
8335-A2-GB20-A0 March 2005 v
About This Guide
Document Purpose and Intended Audience
This guide contains information needed to set up, configure, and operate the Model 8335, 8355, 8365, 8375, and 8385 ATM Line Cards, and is intended for installers and operators.
Document Summary
A master glossary of terms and acronyms used in Paradyne documents is available on the World Wide Web at www.paradyne.com. Select Support
Technical Manuals Technical Glossary.
Section Description
Chapter 1, About the ATM Line Cards
Describes the card’s features and capabilities.
Chapter 2, Menus and Screens Provides instructions for accessing the user interface
and navigating the screens.
Chapter 3, Configuration Provides instructions for configuring the unit.
Chapter 4, Monitoring Describes how to use the LEDs, status messages, and
statistics to monitor the unit.
Chapter 5, Diagnostics Provides instructions for viewing self-test results and
alarms, and for running an ATM Ping and line loopback test.
Chapter 6, Maintenance
Procedures
Provides instructions for clearing NVRAM, uploading or downloading a configuration, downloading firmware, and resetting the card.
Appendix A, SNMP Traps Contains SNMP trap compliance information.
Appendix B, Connector Pin
Assignments
Lists the pin assignments for the BLC Telco connectors.
Appendix C, Technical
Specifications
Contains physical and regulatory specifications, and power consumption values.
Index Lists key terms, acronyms, concepts, and sections in
alphabetical order.
Page 8
About This Guide
vi March 2005 8335-A2-GB20-A0
Product-Related Documents
Complete documentation for this product is available online at www.paradyne.com. Select Support Technical Manuals.
To order a paper copy of a Paradyne document, or to speak with a sales representative, please call 1-727-530-2000.
Document Number Document Title
6390-A2-GK40 Hotwire ReachDSL Modem, Model 6390 with Inline Phone Filter,
Installation and Operation Supplement
6390-A2-GN10 Hotwire ReachDSL Modem, Model 6390 with Inline Phone Filter,
Installation Instructions
8000-A2-GB22 Hotwire Management Communications Controller (MCC) Card,
IP Conservative, User’s Guide
8021-A2-GB20 Hotwire Shelf Concentration Module (SCM) Card User’s Guide
8335-A2-GZ40 Hotwire ATM Line Cards, Models 8335, 8355, 8365, 8375, and
8385, Installation Instructions
8620-A2-GN20 8620 Broadband Loop Carrier Installation Guide
8820-A2-GN20 8820 Broadband Loop Carrier Installation Guide
Page 9
8335-A2-GB20-A0 March 2005 1-1
1
About the ATM Line Cards
Hotwire ATM Line Cards
The Hotwire® 8335, 8355, 8365, 8375, and 8385 Asynchronous Transfer Mode (ATM) Line Cards are circuit boards mounted in an 8620 or 8820 Broadband Loop Carrier (BLC) and used to transport ATM cells at high speeds over a single twisted-pair connection.
Model 8335 supports Symmetric Digital Subscriber Line (SDSL). It can be set
to AutoBaud to the highest rate the loop can support, or to use a fixed line rate from 144 to 2320 kbps.
Model 8355 supports ReachDSL
®
. It automatically adjusts to the highest rate
the loop can support, from 32 to 2176 kbps.
Model 8365 supports Asymmetric Digital Subscriber Line (ADSL). It can be
set to adapt to the line conditions at startup, or set to the following fixed rates depending on line code:
— G.dmt and ANSI T1.413: 32 to 8000 kbps downstream and 32 to 832 kbps
upstream.
— G.lite: 64 to 3008 kbps downstream and 32 to 512 kbps upstream.
Model 8375 supports ReachDSL+, giving it the capabilities of the Models 8355
and 8365 in one card.
Model 8385 supports Single-pair High-speed Digital Subscriber Line
(SHDSL). It can be set to adapt to the line conditions at startup, or set to a fixed line rate from 200 to 2312 kbps.
Part of Paradyne’s Hotwire Connected™ program, the cards interoperate with third-party DSL endpoints providing end users with the ability to select the best equipment to fit their application. The new line cards also integrate support for multiple DSL services on a single card.
Page 10
1. About the ATM Line Cards
1-2 March 2005 8335-A2-GB20-A0
ATM Line Card Features
The ATM Line Cards have these standard features:
Asynchronous Terminal Interface (ATI). Provides a menu-driven
VT100-compatible terminal interface for configuring and managing the unit locally or remotely by Telnet session.
Alarm indication. Activates front panel LEDs.
Diagnostics. Provides OAM F5 loopback (ATM Ping), self-test, and line
loopback.
Device and test monitoring. Provides the capability of tracking and
evaluating the unit’s operation, including health and status, and error-rate monitoring.
Software upgrade. Supports software upgrades using TFTP.
DSL Features
The cards’ DSL features include:
High speeds and multiple line codes:
— Model 8335 supports data rates up to 2320 kbps upstream and
downstream using 2B1Q line code.
— Model 8355 supports data rates up to 2176 kbps upstream or downstream
using ReachDSL line code.
— Model 8365 supports data rates up to 3008
kbps downstream and
512 kbps upstream using G.lite line code. It can also support data rates up to 8000 kbps downstream and 832 kbps upstream using G.dmt or ANSI line code.
— Model 8375 supports data rates up to 11584 kbps downstream and
896 kbps upstream in S=1/2 mode, up to 3008
kbps downstream and
512 kbps upstream using G.lite line code, up to 8000 kbps downstream and 832 kbps upstream using G.dmt or ANSI line code, and up to 2176 kbps upstream or downstream using ReachDSL line code.
— Model 8385 supports data rates up to 2312 kbps upstream and
downstream using Trellis-Coded Pulse Amplitude Modulation (TC PAM) line code.
High density:
— Model 8335 provides 16 subscriber line ports on each card.
— Model 8365 provides 12 subscriber line ports on each card.
— Models 8355, 8375, and 8385 provide 24 subscriber line ports on each
card.
Page 11
1. About the ATM Line Cards
8335-A2-GB20-A0 March 2005
1-3
ATM Features
The cards’ ATM features include:
Classes of service. Supports traffic management service categories
necessary to support voice and data applications:
—CBR
— rt-VBR
—nrt-VBR
— UBR (only class of service supported for the Model 8355)
Auto configuration. Two Virtual Channel Connections (VCCs) per port are
automatically configured, providing data and voice services.
Multiple virtual circuits. Up to 250 additional VCCs can be configured by the
user and assigned among the DSL ports.
ATM statistics. Maintains statistics for:
— Total cells received
— Total cells transmitted
— Total cells dropped
— Loss of cell delineation events
— Cells with corrected Header Error Control (HEC; Model 8335 only)
— Cells with uncorrectable HEC
Endpoint Support Features
The cards’ endpoint support features include:
Third-party endpoint support. The Models 8335, 8365, 8375, and 8385 line
cards support third-party endpoints through the Hotwire Connected program, including Integrated Access Devices (IADs) and data-only endpoints from numerous industry-leading vendors. The Model 8385 card supports third-party endpoints using the ITU SHDSL standard. A list of Paradyne’s SHDSL partners is available on the World Wide Web at www.paradyne.com. Select Partners Hotwire Connected Interoperability Program.
Model 6381 Modem support. Model 8355, 8365, and 8375 line cards support
the Model 6381 bridge/router.
Model 6390 Modem support. Model 8355 and 8375 line cards support the
Hotwire Model 6390 modem.
Automatic rate adaptation. The card and the endpoint negotiate the best
rate, limited if desired by the user, through automatic rate adaptation. For 2B1Q (Model 8335) the Conexant AutoBaud algorithm is used.
Page 12
1. About the ATM Line Cards
1-4 March 2005 8335-A2-GB20-A0
Network Configurations
Figure 1-1 shows the ATM Line Card used to carry voice over DSL.
Figure 1-1. Endpoint with Voice Interfaces
Figure 1-2 shows a configuration in which the endpoints include a router to provide
data encapsulation.
Figure 1-2. Router Endpoint
00-16682
AT M
Network
ATM Cells
DSL
Integrated
Access
Device
(IAD)
SCM
Hotwire ATM
Line Card
GranDSLAM
Customer Premises
LAN
ISP
Corporate
Site
ATM Cells
Voice
Gateway
PSTN Voice
Traffic
00-16681-01
AT M
Network
Router
ATM Cells
ATM Cells
DSL
SCM
Hotwire ATM
Line Card
GranDSLAM
Customer Premises
LAN
ISP
Corporate
Site
Page 13
1. About the ATM Line Cards
8335-A2-GB20-A0 March 2005
1-5
SNMP Management Capabilities
The ATM Line Cards support SNMP Version 1, and can be managed by Paradyne’s OpenLane
®
or any industry-standard SNMP manager.
Management Information Base (MIB) Support
For a detailed description of supported MIBs, visit Paradyne’s Web site at www.paradyne.com. The following MIBs are supported:
ATM Forum SNMP M4 Network Element View (af-nm-0095.001)
Definitions of Managed Objects for the ADSL Lines (RFC 2662)
Definitions of Managed Objects for ATM Management (RFC 2515)
Definitions of Managed Objects for HDSL2 and SHDSL Lines
(draft-ietf-adslmib-hdsl2-10.txt)
Definitions of Textual Conventions and OBJECT-IDENTITIES for ATM
Management (RFC 2514)
Evolution of MIB II Interfaces (RFC 2863)
ADSL Extension MIB (Models 8365 and 8375 only)
(draft-ietf-adslmib-adslext.txt)
SHDSL MIB (Model 8385 only) (draft-ietf-adslmib-hdsl2.txt)
Entity MIB Using SMIv2 (RFC 2037)
MIB II and the Interfaces Group MIB (RFC 1213, RFC 2233)
Paradyne enterprise MIBs for:
— Hotwire xDSL Interface
— SLE Device Control
— SLE Device Health and Status
—MaxVciVpi-MIB Table
—IF-MIB Table
— ATM VPL Statistics Table
SNMP Trap Support
The ATM Line Cards support SNMP traps as shown in Appendix A, SNMP Traps.
Page 14
1. About the ATM Line Cards
1-6 March 2005 8335-A2-GB20-A0
Page 15
8335-A2-GB20-A0 March 2005 2-1
2
Menus and Screens
Menu and Screen Formats
The Hotwire BLC has an ASCII-based menu- and screen-driven user interface system that enables the user to configure and monitor the Hotwire cards. This section describes the components of a typical Hotwire menu and screen.
A typical Hotwire menu format is shown below:
1. Menu Title is the top line of the menu window that displays the title of the menu or submenu.
2. Menu List is the portion of the menu window that displays the list of menu options. When selected (by using the up and down arrow keys to move the cursor position), a menu option displays a submenu window.
3. Letter Navigation Keys are provided within a menu list. These keys provide an alternative method for selecting menu items.
For example, from the Hotwire – DSL menu illustrated above, you can press the A key to select the Configuration menu item. The Configuration menu appears. You can then press the A key to select the Card Status menu item, and subsequently the Card Info menu item.
Some menu items not active for this product are displayed as placeholders in the menu lists so that letter navigation keys are the same for all related products.
1
2
3
Page 16
2. Menus and Screens
2-2 March 2005 8335-A2-GB20-A0
Components of a Hotwire Screen
A typical Hotwire screen looks like this:
1. System Header Line is the top right line of the screen. This line contains two fields of system login information:
— The first field displays a user-defined chassis or individual card name. If
you have not defined the system name, <no name> appears.
— The second field displays the previous remote or local login depending on
what is currently displayed in the middle field (such as the current login). If the current login is local, the last field displays the previous remote login. If the current login is remote, the last field displays the previous local login.
2. Display Area is the main body of the screen. This area contains the screen name in a “tab” at the upper left, and fields displaying data and/or requiring input. The input values themselves are entered in the Input Line at the bottom of the screen.
3. Input Line is in the lower area of the screen. This area displays prompts after which you enter values for the field highlighted in the Display Area.
If a field has predefined permitted values, you need only type enough of a value to distinguish it from other permitted values. For example, if the Behavior field has a value of Fixed or AutoBaud, you need only type f or a, respectively, and press Enter, to select a value.
1
2
3 4
Page 17
2. Menus and Screens
8335-A2-GB20-A0 March 2005
2-3
4. Status Line is the last line of the screen. It displays status about the selected card and all interfaces. Each time the screen is refreshed, one of the following lines is displayed in rotation:
Line 1:
Slot 02: 8335: Card Status: _ _ _ Wan Status: U
Line 2: Slot 02: 8335: D D D D D D D D D D D D D D D D Line 3: Slot 02: 8335: Press ? For Help
Naming Conventions for Ports and Interfaces
Special naming conventions exist for the Port Name and Interface Name fields.
Port Name – Identifies a physical port. It consists of a family name (dsl for a
DSL card), and a port number. The port number can range from 1 to the number of ports on the card. For example: dsl12.
Interface Name – Identifies a logical connection. It consists of a family name
and a port number (same as the port name), followed by a number identifying a logical interface on the port. Currently the interface number is limited to 1. For example: dsl12:1.
Line 1 Text Description
Slot nn Slot number of the card
8335, 8355, 8365, 8375, or 8385
Model number of selected card
Card Status:
_ or T
_ or M
_ or R
Test mode. Card currently in test mode (T) or _ for no active test.
Major alarm. Major alarm present on card (M) or _ for no active major alarm.
Minor alarm. Minor alarm present on card (R) or _ for no minor alarm active.
Wan Status:
D or U
Uplink status:
D=Down, U=Up
Line 2 Text Description
Slot nn Slot number of the card
8335, 8355, 8365, 8375, or 8385
Model number of selected card
D, U, or X Physical status of the ports:
D=Down, U=Up, X=Disabled
Line 3 Text Description
Slot nn Slot number of the card
8335, 8355, 8365, 8375, or 8385
Model number of selected card
Press ? For Help Press the ? key to view the online Help screen.
Page 18
2. Menus and Screens
2-4 March 2005 8335-A2-GB20-A0
General Navigation Keys
Pop-Up Menu Navigation Keys
Table 2-1. General Navigation Keys
Keys Definition
Backspace, Del, Ctrl-d Erases the character to the left of the prompt.
Ctrl-e Returns to the card selection screen from any screen.
Ctrl-r Resets counters (on monitoring statistics displays).
Ctrl-u Clears the current input or prompt line.
Ctrl-v Displays pop-up menus.
Esc h, ? Displays the online Help screen.
Esc l, Ctrl-l Refreshes the screen.
Esc n Goes to the next window.
Esc p, Ctrl-z Goes back to the previous window.
Esc t, Ctrl-a, Ctrl-c, Ctrl-t, or Ctrl-y
Goes back to the original, top-level window.
Left arrow, Ctrl-b Moves the cursor to the left.
Right arrow, Ctrl-f Moves the cursor to the right.
Up arrow, Ctrl-p Moves up to the previous menu selection or entry field.
Down arrow, Ctrl-n Moves down or to the next selection.
Enter Accepts entry.
Table 2-2. Pop-Up Menu Navigation Keys
Keys Definition
Ctrl-w Scrolls up one page.
Ctrl-x Scrolls down one page.
Up Arrow, Ctrl-p Moves cursor up one menu item.
Down Arrow, Ctrl-n Moves cursor down one menu item.
Ctrl-z Exits pop-up menu without accepting selected entry.
Enter Accepts selected entry and exits pop-up menu.
Page 19
2. Menus and Screens
8335-A2-GB20-A0 March 2005
2-5
User Login Screen (MCP)
You can log in to the Hotwire DSL system using either a local VT100-compatible terminal or a remote Telnet connection. However, the Hotwire DSL system accepts only one login session at a time.
The User Login screen appears if one or more users have been defined on the Management Communications Processor (MCP).
Enter your login ID and password. The login ID and password are case-sensitive.
If you have RADIUS Authentication, this verification may take several minutes as each RADIUS server is contacted one at a time.
If you are denied access during a Telnet session, the session stops and an error is logged. If you are using a console, you are automatically returned to the User Login screen.
NOTE:
If you forget your password, contact your Technical Service Center. Have the serial number of the MCP card available, and the service representative will provide you with a password.
After entering your login ID and password, the system displays the Hotwire Chassis Main Menu.
Page 20
2. Menus and Screens
2-6 March 2005 8335-A2-GB20-A0
Quick Card Select Screen
The Quick Card Select screen displays all the cards in the chassis and lets you Telnet to a selected card in the chassis. Information is displayed only for populated slots. See the Hotwire Management Communications Controller
(MCC) Card, IP Conservative, User’s Guide for more information about the
Hotwire Chassis Main Menu.
Procedure
To select a card:
1. From the Hotwire Chassis Main Menu, select A for Quick Card Select.
2. At the Goto: prompt, type the slot number of the desired card and press Enter.
The appropriate menu appears.
Page 21
2. Menus and Screens
8335-A2-GB20-A0 March 2005
2-7
The following information is displayed on the Quick Card Select screen.
Table 2-3. Quick Card Select Screen
Column Heading Display Description
Slot <slot number> Slot number of card in chassis.
Card <model number> Model number of card.
Type <card type(ports)> Card type followed, if appropriate, by the number of
ports it supports. For example, SCM, SDSL(16), Reach(24), ADSL(12),or SHDSL(24).
Status Position 1: T or _ Test mode. Card currently in test mode or _ for no
active test.
Position 2: M or _ Major alarm. Major alarm present on card or _ for no
active major alarm.
Position 3: R or _ Minor alarm. Minor alarm present on card or _ for no
minor alarm active.
UpLinks <uplink status> Status of uplink:
U=Up, D=Down, X=Disabled, A=Alarm
ATM <ATM uplink status> Status of ATM uplink:
U=Up, D=Down, X=Disabled, A=Alarm
Links <dsllink status> Status of DSL ports:
U=Up, D=Down, X=Disabled, A=Alarm, E=Empty slot
Page 22
2. Menus and Screens
2-8 March 2005 8335-A2-GB20-A0
Exiting from the System
You can manually log out of the system or, after a set number of minutes of inactivity, the system will automatically log you out.
Manually Logging Out
Procedure
To exit from the Hotwire DSL system:
1. Return to the Card Selection screen by selecting Exit from either the Hotwire – MCC menu or the Hotwire – DSL menu.
2. Press Ctrl-z.
3. From the Hotwire Chassis Main Menu, select Logout.
The system exits from the current login session on the Hotwire DSL system.
Automatically Logging Out
The DSL system has an automatic timeout feature that logs you out of the system after five minutes (on the MCP) or ten minutes (on the line card) of inactivity. You will need to log back in to continue your work.
To log back in, press Enter to display the User Login screen and log in.
Page 23
8335-A2-GB20-A0 March 2005 3-1
3
Configuration
Overview
This chapter provides instructions on how to access the system for the first time and perform initial setup procedures. These procedures may include:
Entering Card Information on page 3-2
Setting Spectrum Management (Models 8355, 8375, and 8385) on page 3-4
Configuring the DSL Ports on page 3-8
Configuring the ATM Physical Layer (Models 8335, 8365, and 8385) on
page 3-28
Configuring ATM Parameters on page 3-30
Configuring ATM Cross Connections on page 3-32
Configuring ATM Traffic Profiles on page 3-36
Clearing Cross Connections on page 3-41
Configuring Rate Shaping (Models 8335, 8365, 8385) on page 3-42
Entering Service Node Management Configuration Information (Models 8335
and 8385) on page 3-46
In cases where there is a substantive difference between the screens for the different card models, an example for each card model is shown. For most screens the only difference is the model number and number of ports displayed in the message area.
Saving and Restoring Configuration Options
If you have a saved configuration options file you would like to download to the card, or if you would like to save a copy of the current configuration file, use the NVRAM Configuration Loader screen. See Uploading and Downloading a
Configuration in Chapter 6, Maintenance Procedures.
If you have altered configuration options in error and would like to ensure that you are using factory default configuration options, use the Clear NVRAM screen to restore them. See Clearing NVRAM in Chapter 6, Maintenance Procedures.
Page 24
3. Configuration
3-2 March 2005 8335-A2-GB20-A0
Entering Card Information
After accessing your line card for the first time, use the Card Information screen to configure basic information about the card. To access the Card Information screen, follow this menu selection sequence:
ConfigurationCardCard Info (A-A-A)
The Card Information screen appears.
Page 25
3. Configuration
8335-A2-GB20-A0 March 2005
3-3
Procedure
To enter Card Information screen information:
1. Position the cursor in the field you wish to modify. Type the value you want and press Enter.
2. Save the changes as prompted.
For . . . Enter . . .
Card Name Up to 16 alphanumeric characters to identify the card
(Default = blank).
Card Contact Up to 32 alphanumeric characters to identify the
person or organization responsible for the card (Default = blank).
Card Location Up to 16 alphanumeric characters to identify the
location of the card (Default = blank).
ATM Segment Location IDUp to 32 alphanumeric characters to identify the card for
F5 OAM segment loopbacks. If the card receives an OAM loopback cell with a segment loopback destination ID matching the value entered in this field, the card will loop the cell back to the originator (Default = all ones). Refer to ITU-T I.610 for required structure.
Page 26
3. Configuration
3-4 March 2005 8335-A2-GB20-A0
Entering the Time and Date
The Time/Date screen of the Configuration branch of the line card (menu sequence A-A-B) displays time, time zone, and date. The values are configured through the MCP and cannot be modified through the line card. For more information about the Time/Date screens, see Viewing Card Status and
Information in Chapter 4, Monitoring. Refer to the Hotwire Management Communications Controller (MCC) Card, IP Conservative, User’s Guide for
complete information.
Setting Spectrum Management (Models 8355, 8375, and 8385)
The Spectrum Management screen of the Configuration branch of the Models 8355, 8375 and 8385 line card (menu sequence A-A-G) sets the unique regional operational parameters to use for this card. For the Model 8385, the selections differ depending on whether you are using the card in Notrh American (Annex A) or European (Annex B) networks.
The purpose of Spectrum Management is to facilitate a reasonable spectral environment for the coexistence of multiple technologies in the loop plant with an acceptable level of crosstalk between them. In some countries, the DSL service provider must meet the spectrum management specification of that country. For example, in the United Kingdom, it is a requirement that the product comply with OFTel PSD mask for the loop length requested (extra short, short, medium or long). Support for this requirement is provided by enabling the Spectrum Management option on the Spectrum Management screen (A-A-G), and properly setting the Line Length and EWL options on the Port Configuration screen (A-B-B).
NOTE:
Settings on the Spectrum Management screen affect the choices available for the DSL Port Configuration screen (menu sequence A-B-B). See DSL Port
Configuration – Model 8355 on page 3-11 or DSL Port Configuration – Model 8385 on page 3-24 for more information.
Page 27
3. Configuration
8335-A2-GB20-A0 March 2005
3-5
To access the Spectrum Management screen, follow this menu selection sequence:
ConfigurationCardSpectrum Mgt (A-A-G)
For the Model 8355 or Model 8375, the following Spectrum Management screen appears.
Page 28
3. Configuration
3-6 March 2005 8335-A2-GB20-A0
For the Model 8385, the following Spectrum Management screen appears.
Procedure
To enter Spectrum Management screen information:
1. Position the cursor in the field you wish to modify. Type the value you want and press Enter.
For . . . Enter . . .
Region Setting (Model 8385 only)
The unique regional SHDSL operational parameters as defined in ITU G.991.2 that are to be used for this card (Default = Annex A).
Annex A – The operational parameters for North America will be used.
Annex B – The operational parameters for Europe will be used.
Spectrum Management Enable/Disable to limit the DSL speeds on each port
(based on line length) to meet either ANSI T1.417 or BT Access Network Spectrum standard requirements. The selection allows for an acceptable level of crosstalk from multiple technologies in the loop plant as defined by these standards (Default = Disable.).
Enable – Enables Spectrum Management support.
Disable – Disables Spectrum Management support.
Page 29
3. Configuration
8335-A2-GB20-A0 March 2005
3-7
2. Save the changes as prompted.
Other Functions of the Card Menu
See Chapter 6, Maintenance Procedures, for information about the other functions of the ConfigurationCard menu, such as NVRAM Clear and Card Reset.
For . . . Enter . . .
Country Code (Model 8385 only)
The Spectrum Management standard to be used on this Model 8385 card to calculate the speeds allowable to comply with Spectrum Management (Default = USA).
USA – The T1.417 Spectrum Management standard for USA will be used. This setting is only available when Region Setting is set to Annex A.
UK – The ANFP Spectrum Management standard for BT Access Network will be used. This setting is only available when Region Setting is set to Annex B.
Page 30
3. Configuration
3-8 March 2005 8335-A2-GB20-A0
Configuring the DSL Ports
Set the rate and other characteristics of the DSL ports from the DSL Port Configuration screen. To access the DSL Port Configuration screen, follow this menu selection sequence:
ConfigurationPhysical PortsDSL Ports (A-B-B)
DSL Port Configuration – Model 8335
For the Model 8335, the following DSL Port Configuration screen appears.
Page 31
3. Configuration
8335-A2-GB20-A0 March 2005
3-9
Procedure
To enter DSL Port Configuration screen information for the Model 8335:
1. Select an Action:
Edit – To edit fields on the screen.
Reset – To enable the port and cause the DSL line to retrain.
2. Select the Port Name of the port to be configured or reset (dsl1 through dsl16).
3. For Edit mode, position the cursor in the field you wish to modify. Type the value you want and press Enter.
NOTE:
Fixed rate and autobaud are the two methods used for synchronizing the DSL line between the central office equipment and the customer premises equipment.
— Fixed rate is used for applications that cannot tolerate having the
speed of the DSL link change (for example, a TDM application). Fixed rate is the fastest method, and it always trains at the same speed. However, depending on line conditions, training may not occur without errors.
— Autobaud is used for applications that can tolerate having the speed of
the DSL link change (for example, IP traffic). The autobaud algorithm sets the DSL link to the highest error-free speed. Autobaud may try several speeds to find the best rate for the line conditions. As a result, autobaud usually takes longer to train than fixed rate. The training time for autobaud will vary with the line conditions, with some line conditions causing the algorithm to take several minutes.
Regardless of which training mode is used, both DSL units must be set to the same mode.
Page 32
3. Configuration
3-10 March 2005 8335-A2-GB20-A0
4. Save the changes as prompted.
For . . . Enter . . .
Rate Table Standard – Selects the standard rate table for use when
operating with standard endpoints.
Nx128 – Selects the Nx128 rate table for use when operating with nonstandard endpoints (most are multiples of 128).
Behavior The training behavior (Default = Auto Baud):
Fixed – The line card will train only at the rate set in the Fixed Speed field (Standard default = 784 kbps; Nx128 default = 768 kbps).
Auto Baud – The line card will train up to the highest operational rate less than or equal to the rate set in Auto Baud Max Speed.
Fixed Speed The DSL line rate if Behavior is set to Fixed:
Available Standard rates are 144, 272, 400, 528, 784, 1168, 1552, or 2320 kbps (Default = 784 kbps).
Available Nx128 rates are 144, 256, 384, 512, 768, 1024, or 1536 kbps (Default = 784 kbps).
Auto Baud Max Speed
The maximum DSL line rate the card can train to if Behavior is set to Auto Baud:
Available Standard rates are 144, 272, 400, 528, 784, 1168, 1552, or 2320 kbps (Default = 2320 kbps).
Available Nx128 rates are 144, 256, 384, 512, 768, 1024, or 1536 kbps (Default = 1536 kbps).
Auto Baud Target Margin
A range of 0 to 15 dB. The upper limit for margin used by the Autobaud algorithm during training. After training, if the margin is greater than the target margin, the card will attempt to retrain at a higher rate, if the DSL line conditions permit. This field only appears if Autobaud is selected (Default = 9 dB).
Auto Baud Minimum Margin
A range of 0 to 15 dB. The lower limit for margin used by the Autobaud algorithm during training. After training, if the margin is less than the minimum margin, the card will attempt to retrain at a lower rate. This field only appears if Autobaud is selected (Default = 5 dB).
Link Down Count A number from 0 to 900 (Default = 0 (disable).
If the number of DSL Link Down events exceeds the selected number within a 15-minute period, an SNMP trap is sent. If Link Down Count is set to Disable, no Link Down trap is ever sent.
Link Up/Down Trap Enable or Disable to enable/disable link up/down traps
(Default = Enable).
Enable – Enables link up/down traps.
Disable – Disables link up/down traps.
Page 33
3. Configuration
8335-A2-GB20-A0 March 2005
3-11
DSL Port Configuration – Model 8355
For the Model 8355, the DSL Port Configuration screen appears. The options displayed depend on whether Spectrum Management is enabled and what settings are specified in the device’s factory initialization file.
Edit/Reset Model 8355 DSL Ports
Procedure
To enter DSL Port Configuration screen information for the Model 8355:
1. Select an Action:
Edit – To edit fields on the screen.
Reset – To enable the port and cause the DSL line to retrain.
Copy – To copy a DSL port configuation (see Copy Model 8375 DSL Port
Configurations on page 3-23).
2. Select the Port Name of the port to be configured or reset (dsl1 through dsl24).
Page 34
3. Configuration
3-12 March 2005 8335-A2-GB20-A0
3. For Edit mode, position the cursor in the field you wish to modify. Type the value you want and press Enter.
For . . . Enter . . .
EWL (Equivalent Working Length)
The estimated length of the line in kilofeet. This value is usually specified by the carrier. This option is available only if Spectrum Management is set to Enable on the Spectrum Management screen (menu selection A-A-G) and the equivalent working length parameter is specified in the device’s factory initialization file.
EWL = L26 + 3(L24)/4, where L26 is the total length of the 26-gauge cable in the loop excluding any bridged tap and L24 is the total length of 19, 22, or 24-gauge cable in the loop excluding any bridged tap.
8.5 – 14.5 kft in .5 kft increments, or >14.5 kft (Default = 10 kft).
Loop Length The relative loop length of the line. This value is used to
limit transmit rates and maximum transmit power settings according to local spectrum management guidelines, and is usually specified by the carrier. This option is available only if Spectrum Management is set to Enable on the Spectrum Management screen (menu selection A-A-G), and if relative loop length is specified in the device’s factory initialization file.
Short
Medium
Long
Quad The quad cable configuration. This value is used to limit
transmit rates and maximum transmit power settings according to local spectrum management guidelines, and is usually specified by the carrier. This option is available only if Spectrum Management is set to Enable on the Spectrum Management screen (menu selection A-A-G), and if the quad cable configuration is specified in the device’s factory initialization file.
Same
Segregated<=3km
Segregated>3km
POTS Detection Voltage
The voltage used to detect the presence of Plain Old Telephone Service (POTS) on the DSL line:
0 – 74 volts in 1 volt increments, or D for Disable (Default = 3 volts).
Maximum Tx Power ATU-C/ATU-R
The maximum transmission power settings for the ADSL Transmission Unit – Central Office (ATU-C) and ADSL Transmission Unit – Remote Site (ATU-R). The range may be limited according to local guidelines when Spectrum Management is set to Enable on the Spectrum Management screen (menu selection A-A-G):
+12dB – -14dB in 1 dB increments (Default = +12dB)
Page 35
3. Configuration
8335-A2-GB20-A0 March 2005
3-13
Line Profile The name of the general line configuration profile (up to
32 alphanumeric characters). Press Ctrl-v to display a list of all available line profiles configured on the card. Either select an existing profile to change, or select New Profile to create a new line configuration profile. An asterisk (*) indicates the profile is referenced by other ports.
Each profile name must be unique. Up to 30 profiles can be configured. Profiles can be used by multiple ports and can be changed at any time. All ports share a single default line configuration profile as part of the factory defaults. Maximum Tx Rate, Minimum Tx Rate, and Target SNR Margin are part of the general line configuration profile.
Maximum Tx Rate ATU-C/ATU-R
The maximum transmission rate for the ATU-C and ATU-R. The range may be limited according to local guidelines when Spectrum Management is set to Enable on the Spectrum Management screen (menu selection A-A-G):
All cards with Spectrum Management disabled:
ATU-C: 32 2176 kbps in 32 kbps increments
(Default = 2176 kbps)
ATU-R: 32 2176 kbps in 32 kbps increments
(Default = 2176 kbps)
Cards with Spectrum Management enabled and EWL11.5 kbps:
ATU-C: 32 2176 kbps in 32 kbps increments
(Default = 2176 kbps)
ATU-R: 32 1632 kbps in 32 kbps increments
(Default = 1632 kbps)
Cards with Spectrum Management enabled and EWL > 11.5 kft:
ATU-C: 32 1440 kbps in 32 kbps increments
(Default = 1440 kbps)
ATU-R: 32 1088 kbps in 32 kbps increments
(Default = 1088 kbps)
Minimum Tx Rate ATU-C/ATU-R
The minimum transmission rate acceptable for the ATU-C and ATU-R. Any rate below this, sustained for at least 3 seconds, generates a Loss of Signal (LOS) status.
32 kbps – 2176 kbps in 32 kbps increments (Default = 32 kbps).
For . . . Enter . . .
Page 36
3. Configuration
3-14 March 2005 8335-A2-GB20-A0
Target SNR Margin ATU-C/ATU-R
The Signal-to-Noise Ratio (SNR) margin relative to a Bit Error Ratio of 10
-7
required for a successful activation of the port for the ATU-C and ATU-R. The maximum SNR is always 16 dB, while the minimum is always 0 dB. The SNR margin for rate downshift is 3 dB below the Target SNR Margin. When the SNR margin falls below this level, the device will attempt to decrease its transmit rate. The SNR margin for rate upshift is 2 dB above the Target SNR Margin. When the noise margin rises above this level, the device will attempt to increase its transmit rate. Rate shifts occur as soon as the margin threshold is exceeded.
3 dB – 14 dB in 1 dB increments (Default = 4 dB).
Alarm Profile The name of the alarm configuration profile (up to
32 alphanumeric characters). Press Ctrl-v to display a list of all available alarm profiles configured on the card. Either select an existing profile to change, or select New Profile to create a new alarm profile. An asterisk (*) indicates the profile is referenced by other ports.
Each profile name must be unique. Up to 30 profiles can be configured. Profiles can be used by multiple ports and can be changed at any time. All ports share a single default alarm profile as part of the factory defaults. Errored Seconds Trap Threshold, Severely Errored Seconds Trap Threshold, Unavailable Seconds Trap Threshold, Loss of Power Trap Threshold, and Increasing Rate Alarm Threshold are part of the alarm configuration profile.
Errored Seconds Trap Threshold ATU-C/ATU-R
A number from 0 to 900, or a D for Disable (Default = 120).
If the number of DSL Errored Second events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no Errored Second trap is ever sent. If set to 1, a trap is sent after each Errored Seconds event.
Severely Errored Seconds Trap Threshold ATU-C/ATU-R
A number from 0 to 900, or a D for Disable (Default = 15).
If the number of DSL Severely Errored Second events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no Severely Errored Seconds trap is ever sent. If set to 1, a trap is sent after each Severely Errored Seconds event.
Unavailable Seconds Trap Threshold ATU-C/ATU-R
A number from 0 to 900, or a D for Disable (Default = Disable).
If the number of DSL Unavailable Second events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no Unavailable Seconds trap is ever sent. If set to 1, a trap is sent after each Unavailable Seconds event.
For . . . Enter . . .
Page 37
3. Configuration
8335-A2-GB20-A0 March 2005
3-15
4. Save the changes as prompted.
Copy Model 8355 DSL Port Configurations
Procedure
To copy DSL Port Configuration screen information for the Model 8355 to/from another port:
1. Select an Action:
Copy – To copy the configuration of one port to another port.
2. Enter the name of the source port to be copied (dsl1 through dsl24) in the Copy From field.
3. Enter the name of the destination port for the configuration information (dsl1 through dsl24) in the Copy To field.
4. Enter yes at the Save Changes? prompt to copy.
Loss of Power Seconds Trap Threshold AT U - R
A number from 0 to 900, or a D for Disable (Default = Disable).
If the number of Loss of Power Seconds (LOP) events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no LOP trap is ever sent. If set to 1, a trap is sent after each LOP event.
Rate Increase ATU-C/ATU-R
0 to 2176 kbps in 32 kbps increments, or a D for Disable (Default = Disable).
If the current rate is greater than or equal to the previous rate, plus this threshold, an SNMP trap is sent. If set to Disable, traps are disabled for the event.
Rate Decrease ATU-C/ATU-R
0 to 2176 kbps in 32 kbps increments, or a D for Disable (Default = Disable).
If the current rate is less than or equal to the previous rate, minus this threshold, an SNMP trap is sent. If set to 0, traps are disabled for the event.
Link Up/Down Trap Enable or Disable to enable/disable link up/down traps
(Default = Enable).
Enable – Enables link up/down traps.
Disable – Disables link up/down traps.
Initialization Failure Tr a p AT U - C
Enable or Disable to enable/disable InitFailure traps as specified in RFC 2662 (Default = Disable).
Enable – Enables InitFailure traps.
Disable – Disables InitFailure traps.
For . . . Enter . . .
Page 38
3. Configuration
3-16 March 2005 8335-A2-GB20-A0
DSL Port Configuration – Model 8365
For the Model 8365, the following DSL Port Configuration screen appears.
Procedure
To enter DSL Port Configuration screen information for the Model 8365:
1. Select an Action:
Edit – To edit fields on the screen.
Reset – To enable the port and cause the DSL line to retrain.
2. Select the Port Name of the port to be configured or reset (dsl1 through dsl12).
3. For Edit mode, position the cursor in the field you wish to modify. Type the value you want and press Enter.
For . . . Enter . . .
Line Code The physical transport method (Default = Multimode):
Multimode – The line card adapts to the code the endpoint is set for.
DMT – The line code is G.dmt (ITU 992.1). The endpoint must be set to G.dmt.
G.Lite – The line code is G.lite (ITU 992.2). The endpoint must be set to G.lite.
ANSI – The line code is ANSI T1.413, Issue 2. The endpoint must be set to ANSI.
Page 39
3. Configuration
8335-A2-GB20-A0 March 2005
3-17
For . . . Enter . . .
Latency The data stream path for the port (Default = Interleaved):
Fast – The data stream uses the fast path between the line card and the endpoint.
Interleaved – The data stream uses the interleaved path between the line card and the endpoint.
Behavior The training behavior (Default = Adaptive):
Adaptive – The line card will train up to the highest operational rate less than or equal to the rates set in the Downstream Maximum Speed and Upstream Maximum Speed fields.
Fixed – The line card will train only at the rates set in the Downstream Speed and Upstream Speed fields.
Downstream Speed The downstream DSL line rate (in 32 kbps increments) the
card trains to if Behavior is set to Fixed:
DMT and ANSI: 32–8000 kbps (Default = 8000 kbps). G.lite: 64–3008 kbps (Default = 1536 kbps).
Upstream Speed The upstream DSL line rate (in 32 kbps increments) the
card trains to if Behavior is set to Fixed:
DMT and ANSI: 32–832 kbps (Default = 832 kbps). G.lite: 32–512 kbps (Default = 64 kbps).
Maximum Downstream Speed
The maximum downstream DSL line rate (in 32 kbps increments) the card can train to if Behavior is set to Adaptive:
DMT and ANSI: 32–8000 kbps (Default = 8000 kbps). G.lite: 64–3008 kbps (Default = 3008 kbps).
Minimum Downstream Speed
The minimum downstream DSL line rate (in 32 kbps increments) the card can train to if Behavior is set to Adaptive:
DMT and ANSI: 32–8000 kbps (Default = 32 kbps). G.lite: 64–3008 kbps (Default = 64 kbps).
Maximum Upstream Speed
The maximum upstream DSL line rate (in 32 kbps increments) the card can train to if Behavior is set to Adaptive:
DMT and ANSI: 32–832 kbps (Default = 832 kbps). G.lite: 64–512 kbps (Default = 512 kbps).
Minimum Upstream Speed
The minimum upstream DSL line rate (in 32 kbps increments) the card can train to if Behavior is set to Adaptive:
DMT and ANSI: 32–832 kbps (Default = 32 kbps). G.lite: 32–512 kbps (Default = 64 kbps).
Target Margin The noise margin relative to a Bit Error Ratio of 10
-7
required for a successful activation of the port :
0–31 dB in 1 dB increments (Default = 4 dB).
Page 40
3. Configuration
3-18 March 2005 8335-A2-GB20-A0
For . . . Enter . . .
Minimum Margin The noise margin relative to a Bit Error Ratio of 10-7 that the
port will tolerate before attempting to increase the far-end output power:
0–31 dB in 1 dB increments (Default = 15 dB).
Maximum Margin The noise margin relative to a Bit Error Ratio of 10-7 and in
addition to the Target Margin that the port will tolerate before attempting to reduce the far-end output power:
0–31 dB in 1 dB increments (Default = 15 dB)
Error Seconds A number from 0 to 900, or a D for Disable, for upstream and
downstream (Default = 120).
If the number of DSL Errored Second events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no Errored Second trap is ever sent. If set to 1, a trap is sent after each Errored Second event.
Severely Error Seconds
A number from 0 to 900, or a D for Disable, for upstream and downstream (Default = 15).
If the number of DSL Severely Errored Second (SES) events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no SES trap is ever sent. If set to 1, a trap is sent after each SES event.
Unavailable Seconds A number from 0 to 900, or a D for Disable, for upstream and
downstream (Default = 1).
If the number of DSL Unavailable Second (UAS) events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no Unavailable Seconds trap is ever sent. If set to 1, a trap is sent after each UAS event.
SN Loss of Power Count
A number from 0 to 900, or a D for Disable (Default = 1).
If the number of remote Loss of Power (LOP) events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to 0, no LOP trap is ever sent. If set to 1, a trap is sent after each SN LOP event.
Link Down Count A number from 0 to 900, or a D for Disable
(Default = 0).
If the number of DSL Link Down events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no Link Down trap is ever sent. If set to 1, a trap is sent for each Link Down Count event.
Page 41
3. Configuration
8335-A2-GB20-A0 March 2005
3-19
4. Save the changes as prompted.
DSL Port Configuration – Model 8375
For the Model 8375, the following DSL Port Configuration screen appears. The options displayed depend on whether Spectrum Management is enabled and what settings are specified in the device’s factory initialization file.
Edit/Reset Model 8375 DSL Ports
Procedure
To enter DSL Port Configuration screen information for the Model 8375:
1. Select an Action:
Edit – To edit fields on the screen.
Reset – To enable the port and cause the DSL line to retrain.
Copy – To copy a DSL port configuation (see Copy Model 8375 DSL Port
Configurations on page 3-23).
2. Select the Port Name of the port to be configured or reset (dsl1 through dsl24).
For . . . Enter . . .
Link Up/Down Trap Enable or Disable to enable/disable link up/down traps
(Default = Enable).
Enable – Enables link up/down traps.
Disable – Disables link up/down traps.
Page 42
3. Configuration
3-20 March 2005 8335-A2-GB20-A0
3. For Edit mode, position the cursor in the field you wish to modify. Type the value you want and press Enter.
For . . . Enter . . .
Line Mode The protocol or protocols the port can use (Default =
DUAL):
ADSL – The port supports ADSL only.
REACH – The port supports ReachDSL only.
DUAL – The port supports both ADSL and ReachDSL.
ADSL will be used unless the line is too long or noisy to support it.
Line Code The physical transport method (Default = Multimode):
Multimode – The line card adapts to the code the endpoint is set for.
DMT – The line code is G.dmt (ITU 992.1). The endpoint must be set to G.dmt.
G.Lite – The line code is G.lite (ITU 992.2). The endpoint must be set to G.lite.
ANSI – The line code is ANSI T1.413, Issue 2. The endpoint must be set to ANSI.
EWL (Equivalent Working Length)
The estimated length of the line in kilofeet. This value is usually specified by the carrier. This option is available only if Spectrum Management is set to Enable on the Spectrum Management screen (menu selection A-A-G) and the equivalent working length parameter is specified in the device’s factory initialization file.
EWL = L26 + 3(L24)/4, where L26 is the total length of the 26-gauge cable in the loop excluding any bridged tap and L24 is the total length of 19, 22, or 24-gauge cable in the loop excluding any bridged tap.
8.5 – 14.5 kft in .5 kft increments, or >14.5 kft (Default = 10 kft).
Loop Length The relative loop length of the line. This value is used to
limit transmit rates and maximum transmit power settings according to local spectrum management guidelines, and is usually specified by the carrier. This option is available only if Spectrum Management is set to Enable on the Spectrum Management screen (menu selection A-A-G), and if relative loop length is specified in the device’s factory initialization file.
Short
Medium
Long
Page 43
3. Configuration
8335-A2-GB20-A0 March 2005
3-21
Maximum Tx Power ATU-C/ATU-R
The maximum transmission power settings for the ADSL Transmission Unit – Central Office (ATU-C) and ADSL Transmission Unit – Remote Site (ATU-R). The range may be limited according to local guidelines when Spectrum Management is set to Enable on the Spectrum Management screen (menu selection A-A-G):
+12dB to –14dB in 1 dB increments (Default = +12dB)
Line Profile The name of the general line configuration profile (up to
32 alphanumeric characters). Press Ctrl-v to display a list of all available line profiles configured on the card. Either select an existing profile to change, or select New Profile to create a new line configuration profile. An asterisk (*) indicates the profile is referenced by other ports.
Each profile name must be unique. Up to 30 profiles can be configured. Profiles can be used by multiple ports and can be changed at any time. All ports share a single default line configuration profile as part of the factory defaults. Maximum Tx Rate, Minimum Tx Rate, and Target SNR Margin are part of the general line configuration profile.
Maximum Tx Rate ATU-C/ATU-R
The maximum transmission rate for the ATU-C and ATU-R. The range may be limited according to local guidelines when Spectrum Management is set to Enable on the Spectrum Management screen (menu selection A-A-G):
Cards with Spectrum Management disabled:
ATU-C: 32 12000 kbps in 32 kbps increments
(Default = 12000 kbps)
ATU-R: 32 1984 kbps in 32 kbps increments
(Default = 1984 kbps)
Cards with Spectrum Management enabled and EWL11.5 kbps:
ATU-C: 32 12000 kbps in 32 kbps increments
(Default = 12000 kbps)
ATU-R: 32 1984 kbps in 32 kbps increments
(Default = 1984 kbps)
Cards with Spectrum Management enabled and EWL > 11.5 kft:
ATU-C: 32 1440 kbps in 32 kbps increments
(Default = 1440 kbps)
ATU-R: 32 1088 kbps in 32 kbps increments
(Default = 1088 kbps)
Minimum Tx Rate ATU-C/ATU-R
The minimum transmission rate acceptable for the ATU-C and ATU-R. Any rate below this, sustained for at least 3 seconds, generates a Loss of Signal (LOS) status.
32 kbps 2176 kbps in 32 kbps increments (Default = 32 kbps).
For . . . Enter . . .
Page 44
3. Configuration
3-22 March 2005 8335-A2-GB20-A0
Target SNR Margin ATU-C/ATU-R
The Signal-to-Noise Ratio (SNR) margin relative to a Bit Error Ratio of 10
-7
required for a successful activation of the port for the ATU-C and ATU-R. The maximum SNR is always 16 dB, while the minimum is always 0 dB. The SNR margin for rate downshift is 3 dB below the Target SNR Margin. When the SNR margin falls below this level, the device will attempt to decrease its transmit rate. The SNR margin for rate upshift is 2 dB above the Target SNR Margin. When the noise margin rises above this level, the device will attempt to increase its transmit rate. Rate shifts occur as soon as the margin threshold is exceeded.
3 dB 14 dB in 1 dB increments (Default = 4 dB).
Alarm Profile The name of the alarm configuration profile (up to
32 alphanumeric characters). Press Ctrl-v to display a list of all available alarm profiles configured on the card. Either select an existing profile to change, or select New Profile to create a new alarm profile. An asterisk (*) indicates the profile is referenced by other ports.
Each profile name must be unique. Up to 30 profiles can be configured. Profiles can be used by multiple ports and can be changed at any time. All ports share a single default alarm profile as part of the factory defaults. Errored Seconds Trap Threshold, Severely Errored Seconds Trap Threshold, Unavailable Seconds Trap Threshold, Loss of Power Trap Threshold, and Increasing Rate Alarm Threshold are part of the alarm configuration profile.
Errored Seconds Trap Threshold ATU-C/ATU-R
A number from 0 to 900, or a D for Disable (Default = 120).
If the number of DSL Errored Second events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no Errored Second trap is ever sent. If set to 1, a trap is sent after each Errored Seconds event.
Severely Errored Seconds Trap Threshold ATU-C/ATU-R
A number from 0 to 900, or a D for Disable (Default = 15).
If the number of DSL Severely Errored Second events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no Severely Errored Seconds trap is ever sent. If set to 1, a trap is sent after each Severely Errored Seconds event.
Unavailable Seconds Trap Threshold ATU-C/ATU-R
A number from 0 to 900, or a D for Disable (Default = Disable).
If the number of DSL Unavailable Second events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no Unavailable Seconds trap is ever sent. If set to 1, a trap is sent after each Unavailable Seconds event.
For . . . Enter . . .
Page 45
3. Configuration
8335-A2-GB20-A0 March 2005
3-23
4. Save the changes as prompted.
Copy Model 8375 DSL Port Configurations
Procedure
To copy DSL Port Configuration screen information for the Model 8375 to/from another port:
1. Select an Action:
Copy – To copy the configuration of one port to another port.
2. Enter the name of the source port to be copied (dsl1 through dsl24) in the Copy From field.
3. Enter the name of the destination port for the configuration information (dsl1 through dsl24) in the Copy To field.
4. Enter yes at the Save Changes? prompt to copy.
Loss of Power Seconds Trap Threshold AT U - R
A number from 0 to 900, or a D for Disable (Default = Disable).
If the number of Loss of Power Seconds (LOP) events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no LOP trap is ever sent. If set to 1, a trap is sent after each LOP event.
Rate Increase ATU-C/ATU-R
0 to 2176 kbps in 32 kbps increments, or a D for Disable (Default = Disable).
If the current rate is greater than or equal to the previous rate, plus this threshold, an SNMP trap is sent. If set to Disable, traps are disabled for the event.
Rate Decrease ATU-C/ATU-R
0 to 2176 kbps in 32 kbps increments, or a D for Disable (Default = Disable).
If the current rate is less than or equal to the previous rate, minus this threshold, an SNMP trap is sent. If set to 0, traps are disabled for the event.
Link Up/Down Trap Enable or Disable to enable/disable link up/down traps
(Default = Enable).
Enable – Enables link up/down traps.
Disable – Disables link up/down traps.
Init Failure Trap AT U - C
Enable or Disable to enable/disable InitFailure traps as specified in RFC 2662 (Default = Disable).
Enable – Enables InitFailure traps.
Disable – Disables InitFailure traps.
For . . . Enter . . .
Page 46
3. Configuration
3-24 March 2005 8335-A2-GB20-A0
DSL Port Configuration – Model 8385
For the Model 8385, the following DSL Port Configuration screen appears.
Procedure
To enter DSL Port Configuration screen information for the Model 8385:
1. Select an Action:
Edit – To edit fields on the screen.
Reset – To enable the port and cause the DSL line to retrain.
2. Select the Port Name of the port to be configured or reset (dsl1 through dsl24).
3. For Edit mode, position the cursor in the field you wish to modify. Type the value you want and press Enter.
Page 47
3. Configuration
8335-A2-GB20-A0 March 2005
3-25
NOTE:
The range of allowed speeds based on spectrum management requirements as defined in either ANSI T1.417 or BT Access Network Spectrum standards are calculated and displayed on the DSL Port Configuration screen. If Spectrum Management is set to Disable on the Spectrum Management screen (menu selection A-A-G) (see Setting
Spectrum Management (Models 8355, 8375, and 8385) on page 3-4),
then the Allowed Speeds field will display all applicable speeds based on the Region Setting selected on the Specrum Management screen.
For . . . Enter . . .
Port Status Enabled or Disabled.
Estimated Working Length
This option appears only if Spectrum Management is set to Enable and Region is set to Annex A on the Spectrum Management screen (menu selection A-A-G). It is the estimated length of the line in kilofeet, or NoLoad for non-loaded loops. This value is usually specified by the carrier.
EWL = L26 + 3(L24)/4, where L26 is the total length of the 26-gauge cable in the loop excluding any bridged tap and L24 is the total length of 19, 22, or 24-gauge cable in the loop excluding any bridged tap.
8.5 – 14.5 kft in .5 kft increments, or NoLoad.
Line Length This option appears only if Spectrum Management is set to
Enable and Region is set to Annex B on the Spectrum Management screen (menu selection A-A-G). It is the estimated distance from the local exchange, used to determine the speeds that can be supported. This value is usually specified by the carrier. Select from the following (Default = Extra Short):
Extra Short – Can support speeds up to 2312 kbps (in 64 kbps increments).
Short – Can support speeds up to 2056 kbps (in 64 kbps increments).
Medium – Can support speeds up to 1480 kbps (in 64 kbps increments).
Long – Can support speeds up to 840 kbps (in 64 kbps increments).
Allowed Speeds Displays the range of allowed speeds based on spectrum
management requirements. Speeds are selectable in 64 kbps increments.
Behavior The training behavior (Default = Adaptive):
Adaptive – The line card will train up to the highest operational rate less than or equal to the maximum fixed or adaptive speed.
Fixed – The line card will train only at the rate set in the Fixed Rate field.
Page 48
3. Configuration
3-26 March 2005 8335-A2-GB20-A0
Fixed Rate Speed The DSL line rate the card trains to if Behavior is set to
Fixed. Choose from rates listed in the Allowed Speeds field. Speeds are selectable in 64 kbps increments.
Maximum Adaptive Speed
The maximum DSL line rate the card can train to if Behavior is set to Adaptive. Choose from rates listed in the Allowed Speeds field.
Minimum Adaptive Speed
The minimum DSL line rate the card can train to if Behavior is set to Adaptive. Choose from rates listed in the Allowed Speeds field.
Startup Margin The noise margin relative to a Bit Error Ratio of 10
-7
required for a successful activation of the port:
2 – 15 dB in 1 dB increments (Default = 2 dB).
Error Seconds A number from 0 to 900, or a D for Disable
(Default = 120).
If the number of DSL Errored Second events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no Errored Second trap is ever sent. If set to 1, a trap is sent after each Errored Seconds event.
Severely Error Seconds A number from 0 to 900, or a D for Disable
(Default = 15).
If the number of DSL Severely Errored Second events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no Severely Errored Seconds trap is ever sent. If set to 1, a trap is sent after each Severely Errored Seconds event.
Unavailable Seconds A number from 0 to 900, or a D for Disable
(Default = 1).
If the number of DSL Unavailable Second events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no Unavailable Seconds trap is ever sent. If set to 1, a trap is sent after each Unavailable Seconds event.
Loss of Sync Word Seconds
A number from 0 to 900, or a D for Disable (Default =1).
If the number of Loss of Sync Word Seconds events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no Loss of Sync Word Seconds trap is ever sent. If set to 1, a trap is sent after each Loss of Sync Word Seconds event.
CRC Anomaly Threshold
A number from 0 to 900, or a D for Disable (Default =1).
If the number of Cyclical Redundancy Check (CRC) events equals or exceeds the selected number within a 15-minute period, an SNMP trap is sent. If set to Disable or 0, no CRC Anomalies trap is ever sent. If set to 1, a trap is sent after each CRC anomaly event.
For . . . Enter . . .
Page 49
3. Configuration
8335-A2-GB20-A0 March 2005
3-27
4. Save the changes as prompted.
SNR Margin Threshold A number from 0 to 15 (Default = 0).
If the Signal-to-Noise (SNR) ratio (in dB) reaches or drops below the selected value, an SNMP trap is sent.
Attenuation Threshold A number from 0 to 127 (Default = 0).
If the Attenuation reaches or drops below the selected value, an SNMP trap is sent.
Link Down Count A number from 0 to 900, or a D for Disable
(Default = 0).
If the number of DSL Link Down events exceeds the selected number within a 15-minute period, an SNMP trap (Enterprise trap xdslLinkUpDownTransitions(1)) is sent. If Link Down Count is set to Disable or 0, no Link Down trap is ever sent. If set to 1, a trap is sent after each linkUpDownTransition event.
Link Up/Down Trap Enable or Disable to enable/disable link up/down traps
(Default = Enable).
Enable – Enables link up/down traps.
Disable – Disables link up/down traps.
Remote Management Enable or Disable to enable/disable support for remote
management of devices on the SHDSL line from the STU-R via the Embedded Operations Channel (EOC) (Default = Enable).
Enable – Enables remote management support.
Disable – Disables remote management support.
For . . . Enter . . .
Page 50
3. Configuration
3-28 March 2005 8335-A2-GB20-A0
Configuring the ATM Physical Layer (Models 8335, 8365, and 8385)
Determine whether this card will function as an endpoint for ATM OAM loopbacks from the ATM Physical Layer screen. To access the ATM Physical Layer screen, follow this menu selection sequence:
ConfigurationPhysical PortsATM PHY Layer (A-B-C)
The ATM Physical Layer screen appears.
Page 51
3. Configuration
8335-A2-GB20-A0 March 2005
3-29
Procedure
To enter ATM Physical Layer screen information:
1. Select the Port Name of the port to be configured (dsl1:1 through dsl16:1 on the Model 8335, dsl1:1 through dsl12:1 on the Model 8365, or dsl1:1 through dsl24:1 on the Model 8385).
2. Position the cursor in the field you wish to modify. Type the value you want and press Enter.
For . . . Enter . . .
ATM Segment Endpoint
Enable – Defines the port as a segment loopback. The card will check the location ID in a loopback cell and loop the cell if the location ID is valid. Otherwise, the cell will be dropped. A valid location ID matches the preconfigured ID or an all-ones ID.
Disable – The line card will loop a cell only if the location ID matches the preconfigured location ID. All other loopback cells are passed to the next segment (Default = Disable).
Payload Scrambler
(Models 8335 and 8365 only)
Enable – Payload scrambling (as defined in ITU I.432) is enabled (Default = Enable).
Disable – Payload scrambling is disabled.
Page 52
3. Configuration
3-30 March 2005 8335-A2-GB20-A0
Configuring ATM Parameters
Set ATM parameters using the ATM Parameters screen. To access the ATM Parameters screen, follow this menu selection sequence:
ConfigurationATM SwitchATM Parameters (A-E-A)
For the Models 8335, 8365, 8375, and 8385, the following ATM Parameters screen appears:
Page 53
3. Configuration
8335-A2-GB20-A0 March 2005
3-31
For the Model 8355, the following ATM Parameters screen appears:
Procedure
To configure ATM parameters:
1. Select the interface to be changed (dsl1:1 through dsl16:1 on the Model 8335, dsl1:1 through dsl12:1 on the Model 8365, or dsl1:1 through dsl24:1 on the Models 8355, 8375, and 8385).
2. Position the cursor in the field you wish to modify. Type the value you want and press Enter.
3. Save the changes as prompted.
For . . . Enter . . .
CAC Percent Bandwidth Utilization (Models 8335, 8365, 8375, and 8385)
A percentage from 0 to 9999 (Default = 150 for both rt-VBR and nrt-VBR classes of service).
The values represent the amount of oversubscription the Connection Admission Control algorithm allows for the class of service.
Uncorrected HEC Count A number from 0 to 1000, or a D for Disable
(Default = 100).
If the number of HEC errors exceeds the selected number within a 15-minute period, an SNMP trap is sent. If Uncorrected HEC Count is set to Disable or 0, no trap is ever sent. If set to 1, a trap is sent after each Uncorrected HEC Count event.
OCD Event Count (Models 8335, 8365, 8375, and 8385)
A number from 0 to 1000, or a D for Disable (Default = 0).
If the number of Out of Cell Delineation (OCD) events exceeds the selected number within a 15-minute period, an SNMP trap is sent. If OCD Count is set to Disable or 0, no trap is ever sent. If set to 1, a trap is sent after each OCD Event Count event.
Page 54
3. Configuration
3-32 March 2005 8335-A2-GB20-A0
Configuring ATM Cross Connections
Configure virtual circuit connections from the line card to the endpoint with the ATM Cross Connect screen. To access the ATM Cross Connect screen, follow this menu selection sequence:
ConfigurationATM SwitchATM Cross Connect (A-E-B)
For the Model 8335, the following ATM Cross Connect screen appears:
Page 55
3. Configuration
8335-A2-GB20-A0 March 2005
3-33
For the Model 8355 and Model 8375, the following ATM Cross Connect screen appears:
For the Model 8365, the following ATM Cross Connect screen appears:
For the Model 8385, the following ATM Cross Connect screen appears:
Page 56
3. Configuration
3-34 March 2005 8335-A2-GB20-A0
Procedure
To configure ATM cross connections:
1. Select the interface to be changed (dsl1:1 through dsl16:1 on the Model 8335, dsl1:1 through dsl12:1 on the Model 8365, or dsl1:1 through dsl24:1 on the Model 8355, 8375, and Model 8385).
2. Select the Index number of the VC (Virtual Channel) you wish to modify, or 0 to add a new VC.
— Total Connections for this Interface shows the number of connections
defined for the interface.
— Available Connections displays the number of connections still available
for the card.
To scroll to the previous or next group of connections, type u (for Up) or d (for Down) in the Index field.
3. Position the cursor in the field you wish to modify. Type the value you want and press Enter.
For . . . Enter . . .
VPI The VPI (Virtual Path Identifier) of the connection, from
0 to 15.
VCI The VCI (Virtual Channel Identifier) of the connection from
32 to 255.
Profile Name (Models 8335 and 8385)
Tx Profile/Rx Profile (Models 8355 and
8375)
Dnstream Profile/ Upstream Profile (Model 8365)
A default or user-defined ATM traffic profile. Default traffic profiles include AUTOBAUD (Model 8335 only), IP MGT (Model 8365 only), PACK E T, and VOICE. See
Configuring ATM Traffic Profiles on page 3-36. Press
Ctrl-v for a list of valid downstream profiles.
For the Model 8355 or Model 8375, define the profile to be used for ATM traffic both leaving (Tx or downstream) and entering (Rx or upstream) the interface.
For the Model 8365, define the profile to be used for both the downstream and upstream connections.
Status Enable – To enable the connection.
Disable – To disable the connection.
Delete – To delete the connection.
For a connection that already exists, the system displays one of:
Up – VPI/VCI is operational.
Down – VPI/VCI is not operational.
Page 57
3. Configuration
8335-A2-GB20-A0 March 2005
3-35
4. Save the changes as prompted.
For . . . Enter . . .
Seg Endpt (Models 8355 and 8375 only)
Enable or Disable to determine if the card will function as an endpoint for ATM Operations, Adminstration and Maintenance (OAM) loopbacks on the connection.
Enable – To define the card as a segment loopback on this connection. The line card will then check the location ID in a loopback cell and loop the cell if the location ID is valid. If it is not valid (the location ID does not match the preconfigured ID or an all-ones ID), the cell will be dropped (Default = Enable).
Disable – To loop a cell only if the location ID matches the preconfigured location ID. All other loopback cells are passed to the next segment.
CSN The Connection Serial Number (CSN) is an automatically
generated identifier for this connection that associates it with a connection on the SCM card. It consists of the following:
Slot Number (01–18 for the 8820 BLC, 01–03 for the
8620 BLC)
Connection Type (S for Standard or C for Custom)
Por t Number (01–16 on the Model 8335, 01–12 on the
Model 8365, or 01–24 on the Model 8355, 8375, or 8385)
A system-assigned 3-digit sequence number.
You must enter this value on the Cross Connect screen for the SCM card (where it is labeled VID) to make a connection through the system.
Page 58
3. Configuration
3-36 March 2005 8335-A2-GB20-A0
Configuring ATM Traffic Profiles
View and create ATM traffic profiles from the ATM Traffic Profiles screen. Profiles define quality of service and other attributes to control traffic in the network. To access the ATM Profiles screen, follow this menu selection sequence:
ConfigurationATM SwitchATM Traffic Prof (A-E-C)
For the Models 8335, 8365, 8375, and 8385, the following ATM Traffic Profiles screen appears:
Page 59
3. Configuration
8335-A2-GB20-A0 March 2005
3-37
For the Model 8355, the following ATM Traffic Profiles screen appears:
The traffic profiles initially displayed are predefined and cannot be altered.
Table 3-1, Traffic Profile Characteristics, shows their characteristics.
AUTOBAUD (Model 8335 only): This profile allows for packet traffic to the
endpoint that is used during training of the DSL link. It is also used to retrieve statistics from the endpoint during normal operation. There is no PCR (Peak Cell Rate) associated with the profile, since there is no policing.
IP MGT (Models 8335 and 8385 only): This profile is for a management path
to the endpoint that is used by the Network Access Provider to manage the endpoint. This traffic could include SNMP or Telnet traffic. This connection is not policed.
PACKET: This profile allows packet data traffic up to the maximum that the
DSL link can handle. There is no policing associated with this connection. The priority mechanism will ensure that the voice traffic to be sent ahead of the data traffic. This is the only default profile for the Model 8355.
Table 3-1. Traffic Profile Characteristics
Profile Name Class PD POL PCR CDVT SCR MBS
AUTOBAUDUBRNN – – – –
IP MGTUBRY N – – – –
PACKETUBRY N – – – –
VOICE rt-VBR N T 1572 188 16
PD = Packet Discard, POL = Policing, PCR = Peak Cell Rate, CDVT = Cell Delay Variation Tolerance, SCR = Sustainable Cell Rate, MBS = Maximum Burst Size
Page 60
3. Configuration
3-38 March 2005 8335-A2-GB20-A0
VOICE (Models 8335, 8365, 8375, and 8385 only): This profile allocates
enough bandwidth for one voice call (approximately 80 kbps). If more than one voice call is placed on the connection using this profile, then the cells will be tagged (CLP bit set). This profile is policed to 188 cells/sec (enough for one phone call).
Some numeric values on the ATM Traffic Profiles screen represent cells per second. An ATM cell is 53 bytes (48 bytes of data plus 5 bytes of overhead), or 424 bits. Conversion guidelines are listed in Table 3-2, Conversion Guidelines.
A voice circuit typically requires 80
kbps, which is 188 cells per second. ATM cells
are 53 bytes in length (a 5-byte header and 48 bytes for payload). After allowing 4 bytes for the AAL2 overhead, you have approximately 44 bytes available for data. Therefore, the total overhead is 53/44. For a 64 kbps stream, this results in
77.1 kbps (64 x 53/44). The 80
kbps allows extra bandwidth for additional inband
signaling.
The ATM line cards implement Usage Parameter Control (otherwise known as policing) as described in the ATM Forum’s Traffic Management Specification 4.1 (AF-TM-0121.000). According to this specification, traffic contracts for the two VBR ATM service categories (rt-VBR and nrt-VBR) include traffic parameters for Peak Cell Rate (PCR) and Sustainable Cell Rate (SCR). Policing is implemented using the recommended dual Generic Cell Rate Algorithm (GCRA) functions.
Table 3-2. Conversion Guidelines
For Standard Speeds For Nx128k Speeds
Kilobits per second . . .
Equals cells per second . . .
Kilobits per second . . .
Equals cells per second . . .
2320 5471 1536 3623
1552 3660 1024 2415
1168 2755 768 1811
784 1849 512 1208
528 1245 384 906
400 943 256 604
272 642 144 340
144 340
Page 61
3. Configuration
8335-A2-GB20-A0 March 2005
3-39
A problem arises when configuring the two GCRA functions as recommended by TM 4.1 if you specify VBR service and set PCR and SCR to the same value (PCR=SCR). The Maximum Burst Size (MBS) parameter then becomes irrelevant and both GCRA functions end up with the same increment and limit values. This occurs because in every available VBR policing configuration, the action taken for nonconforming cells by the first GCRA function is a superset (more severe or at least as severe as) the action taken by the second GCRA function; the second GCRA function has no effect. Therefore, if you specify a VBR service category and set PCR equal to SCR, the line card uses a single GCRA with the increment based on PCR and limit based on CDVT. The line card ensures conformance only to the PCR value within the CDVT range (specified or default). The MBS parameter has no effect.
Procedure
To configure ATM traffic profiles:
1. Select the Index number (1–10) of the traffic profile you wish to modify, or 0 to add a new traffic profile. Factory default traffic profiles are read-only.
To scroll to the previous or next group of profiles, type u (for Up) or d (for Down) in the Index field.
2. Position the cursor in the field you wish to modify. Type the value you want and press Enter.
For . . . Enter . . .
Profile Name Up to 12 alphanumeric characters.
Class The class of service (listed below in priority order):
CBR – Constant Bit Rate.
rt-VBR – Real-time Variable Bit Rate.
nrt-VBR – Non-real-time Variable Bit Rate.
UBR – Unspecified Bit Rate. This is the only class available
for Model 8355.
PD The Early Packet Discard (EPD) and Partial Packet Discard
(PPD) features setting:
Yes – EPD and PPD are used when congestion is detected.
No – EPD and PPD are not used.
POL (Models 8335, 8365, and 8385 only)
The Policing mode:
N – None. All cells are forwarded to the SCM.
T – Tag. All cells are forwarded to the SCM, but
nonconforming cells (cells which do not comply with the traffic contract) have their Cell Loss Priority bits set to 1.
D – Drop. Nonconforming cells are dropped.
PCR (Models 8335, 8365, and 8385 only)
The Peak Cell Rate. Permitted values are 1 up to the DSL line rate.
Page 62
3. Configuration
3-40 March 2005 8335-A2-GB20-A0
3. Save the changes as prompted.
For . . . Enter . . .
CDVT (Models 8335, 8365, and 8385 only)
The Cell Delay Variation Tolerance, in tenths of microseconds. Permitted values are 1 through 156000.
SCR (Models 8335, 8365, and 8385 only)
The Sustained Cell Rate, if applicable. Permitted values are 1 up to the PCR.
MBS (Models 8335, 8365, and 8385 only)
The Maximum Burst Size, if applicable. Permitted values are 1 up to 1000 cells/sec.
Page 63
3. Configuration
8335-A2-GB20-A0 March 2005
3-41
Clearing Cross Connections
Delete all user-defined ATM connections for an interface using the Clear Cross Connects screen. This is useful if you have downloaded a configuration for a different network, or have defined a large number of connections in error. To access the Clear Cross Connects screen, follow this menu selection sequence:
ConfigurationATM SwitchClear X-Connects (A-E-D)
The Clear Cross Connects screen appears.
Procedure
To clear cross connects:
1. Select the interface to be cleared (dsl1:1 through dsl16:1 on the Model 8335, dsl1:1 through dsl12:1 on the Model 8365, or dsl1:1 through dsl24:1 on the Model 8355, 8375, and Model 8385).
2. Select Yes and press Enter.
Do not select Yes unless you wish to delete all the Custom connections on the interface.
Page 64
3. Configuration
3-42 March 2005 8335-A2-GB20-A0
Configuring Rate Shaping (Models 8335, 8365, 8385)
Configure rate shaping for ATM traffic being sent to the SCM card. To access the Rate Shaping screen, follow this menu selection sequence:
ConfigurationATM SwitchRate Shaping (A-E-E)
The Rate Shaping Configuration screen appears.
Procedure
To configure rate shaping:
1. Select the interface to be changed (dsl1:1 through dsl24:1 on the Model 8385).
2. Enter the rate shape value limit for WAN traffic (512 kbps to 46080 kbps in 64 kbps increments), or d to disable rate shaping. Setting the rate shape limit to 0 or d turns rate shaping off, which is the same a setting the limit to 46080 kbps. The default value is 27000 kbps.
3. Press Ctrl-z and save the changes as prompted.
Page 65
3. Configuration
8335-A2-GB20-A0 March 2005
3-43
Entering Service Node Configuration Information (Models 8335, 8365, 8375, and 8385)
Record information about the endpoint using the SN (Service Node) Configuration screen. To access the SN Configuration screen, follow this menu selection sequence:
ConfigurationSN ConfigurationSN Config (A-F-A)
For the Model 8335, the following SN Configuration screen appears.
Page 66
3. Configuration
3-44 March 2005 8335-A2-GB20-A0
For the Model 8365 or 8375, the following SN Configuration screen appears.
For the Model 8385, the following SN Configuration screen appears.
Page 67
3. Configuration
8335-A2-GB20-A0 March 2005
3-45
Procedure
To enter SN Configuration screen information:
1. Select the interface to be changed (dsl1:1 through dsl16:1 on the Model 8335, dsl1:1 through dsl12:1 on the Model 8365, or dsl1:1 through dsl24:1 on the Model 8385).
2. Position the cursor in the field on the top half of the screen that you wish to modify. Type the value you want and press Enter.
NOTES:
— The fields listed above are stored in the Paradyne enterprise MIB.
Values for these fields may have already been retrieved from the attached endpoint if this information has been configured at the endpoint. If no information is provided from the endpoint, you can enter it here. If you attempt to enter information into fields already configured at the endpoint, your entries will not be saved.
— The fields at the bottom of the screen are read-only. This information
is retrieved from the endpoint when the line is operational. If the endpoint does not provide information for one or more of these fields, blanks are displayed.
3. Press Ctrl-z and save the changes as prompted.
For . . . Enter . . .
Name Up to 16 alphanumeric characters to identify the endpoint
(Default = blank).
Contact Up to 32 alphanumeric characters to identify the person or
organization responsible for the endpoint (Default = blank).
Location Up to 16 alphanumeric characters to identify the
location of the endpoint (Default = blank).
Circuit ID Up to 32 alphanumeric characters to identify the circuit
(Default = blank).
Page 68
3. Configuration
3-46 March 2005 8335-A2-GB20-A0
Entering Service Node Management Configuration Information (Models 8335 and 8385)
For Models 8335 and 8385 only, enter or change the connection that the DSL provider uses for IP management of the SN. This connection will be maintained through a power recycle. To access the SN Management Config screen, follow this menu selection sequence:
ConfigurationSN ConfigConfig SN Mgt (A-F-B)
The Service Node Management Config screen appears.
Page 69
3. Configuration
8335-A2-GB20-A0 March 2005
3-47
Procedure
To configure SN management:
1. Select the Index number (1–10) of the management channel(s) you wish to modify, or 0 to add a new management channel.
To scroll to the previous or next group of management channels, type u (for Up) or d (for Down) in the Index field.
2. Position the cursor in the field you wish to modify. Type the value you want and press Enter.
3. Press Ctrl-z and save the changes as prompted.
For . . . Enter . . .
Interface Select the interface to be configured (dsl1:1 through
dsl16:1 on the Model 8335 or dsl1:1 through dsl24:1 on
the Model 8385).
IP Address The IP address that the DSL provider will use to manage the
SN. Duplicate endpoint/management IP addresses are not allowed. This field is normally specified through the NMS interface, although you can also specify it here. If you clear this field, the route to the SN and the ATM connection are deleted.
Subnet Mask The IP subnet mask that the DSL provider will use to
manage the SN. This field is normally specified through the NMS interface, although you can also specify it here.
VPI The VPI of the connection, from 0 to 15 (Default = 0).
The default of 0 should be used in most cases since all certified SNs are configured to use the factory default.
VCI The VCI of the connection, from 32 to 255 (Default = 33).
The default of 33 should be used in most cases since all certified SNs are configured to use the factory default.
Page 70
3. Configuration
3-48 March 2005 8335-A2-GB20-A0
Page 71
8335-A2-GB20-A0 March 2005 4-1
4
Monitoring
What to Monitor
This chapter presents information on how to monitor unit status and assess performance by:
Viewing Card Status and Information on page 4-2
— View card information, date and time, and system log.
Viewing Physical Ports Status on page 4-4
— View the list of active ports, ATM physical layer information, DSL link
performance, and DSL error statistics.
Monitoring ATM Activity on page 4-11
— View the ATM parameters, cross connections, aggregate statistics, VCC
performance statistics, the unknown cell log, and ATM connection status.
Monitoring SN Information on page 4-18
— View system information about the Service Node.
Viewing the Front Panel LEDs on page 4-20
— Check ATM bus and DSL port activity.
Page 72
4. Monitoring
4-2 March 2005 8335-A2-GB20-A0
Viewing Card Status and Information
Use the Card screens to display information about the system.
Procedure
To view general card information, time and date, and the system log:
1. Follow this menu selection sequence:
MonitoringCard (B-A)
2. Select the submenu option as shown in Table 4-1, Monitoring – Card Options, and press Enter.
Page 73
4. Monitoring
8335-A2-GB20-A0 March 2005
4-3
Table 4-1. Monitoring – Card Options
Card Info Screen B-A-A
Displays card information entered on the Card Info configuration screen and internal to the card:
Card Name – The name assigned to the card.
Card Contact – Information about the person responsible for the card.
Card Location – The location of the system.
Card Up Time – Time elapsed (in days, hours, minutes, and seconds) since the card was
last powered up or reset.
Typ e – The type of card (DSL).
Model Number – The model number of card.
Serial Number – The serial number of card.
Firmware Revision – The firmware version number.
Hardware Revision – The hardware version number.
Line Code Revision – The digital signal processor code version number.
PLD Revision – The Programmable Logic Devices (PLD) code version number.
Specific PLD Revision (Models 8355, 8375, and 8385 only) – The Programmable Logic
Devices (PLD) code version number for additional devices on this card.
Time/Date Screen B-A-B
Displays the line card’s time and date, which is maintained by the MCP. Time and date can be changed from an MCP configuration screen. See the Hotwire Management
Communications Controller (MCC) Card, IP Conservative, User’s Guide for more
information.
Local Time/Date – The local time in hours:minutes format followed by am or pm, and the local date in month/day/year format.
Syslog Screen B-A-C
Displays a list of significant events that have occurred on the line card, in order by date and time. The system log can contain up to 100 entries.
Select an Action to display a different group of up to 17 system log entries: Newest, Oldest, Up, or Down.
Each system log entry is displayed on a single line. For example:
MON NOV 26 14:47:48 Download completed MON NOV 26 14:52:48 System started
Page 74
4. Monitoring
4-4 March 2005 8335-A2-GB20-A0
Viewing Physical Ports Status
Use the Physical Ports screens to display information about physical ports.
Procedure
To view the active ports list and DSL statistics:
1. Follow this menu selection sequence:
MonitoringPhysical Ports (B-B)
Page 75
4. Monitoring
8335-A2-GB20-A0 March 2005
4-5
2. The Physical Ports menu appears. Select the submenu option as shown in
Table 4-2, Monitoring – Physical Ports, and press Enter.
Table 4-2. Monitoring – Physical Ports (1 of 6)
Active List Screen B-B-A
Displays a list of the current status of all the active ports.
Scroll through the ports by entering D for Down or U for Up, or enter a port number to have that port displayed at the top of the screen.
Num – Number of the port.
Name – Name of the port (dsl1 through dsl16 on the Model 8335, dsl1 through dsl12 on
the Model 8365, and dsl1 through dsl24 on the Model 8355, 8375, or 8385).
Status – Status of the port:
In-use: The port is enabled and in communication with the endpoint.
Disconnected: The port was previously connected to the endpoint, but no longer
detects energy on the line. For Model 8355, could also indicate that the line is dormant.
Training/Dormant (Models 8335, 8365, 8375, and 8385): The port is waiting for
outside input. The port has either detected energy on the line and is attempting to establish communication with the endpoint, or the port has never detected energy on the line and is dormant.
Training (Model 8355): The port has detected energy on the line and is attempting to
establish communication with the endpoint.
Test: A disruptive test is being run on the port.
Disabled: The port has been administratively disabled.
ATM Physical Layer Screen Models 8335, 8365, and 8385 Only B-B-C
Shows configuration settings for the ATM physical layer.
Enter a port name (dsl1 through dsl16 on the Model 8335, dsl1 through dsl12 on the Model 8365, and dsl1 through dsl24 on the Model 8385) to see configuration settings.
ATM Segment Endpoint – Indicates whether connections on this port are configured to act as segment endpoints for ATM OAM loopbacks as defined in ITU I.610.
Payload Scrambler – Indicates whether payload scrambling as defined in ITU I.432 is enabled.
Page 76
4. Monitoring
4-6 March 2005 8335-A2-GB20-A0
DSL Link Performance Summary Screen – Model 8335 B-B-D
Shows performance statistics for the DSL link at the physical layer.
Enter a port name (dsl1–dsl16) to see statistics for the current 15-minute period, previous 15-minute period, previous 1-hour period, and current day.
Operating Speed – The DSL line speed in kbps.
Down Margin – The margin reported by the endpoint, in dB. The larger the number, the
higher the link’s tolerance to noise.
Down Attenuation – The signal attenuation reported by the endpoint, in dB. Generally, the larger the number, the longer the loop.
Up Margin – The margin detected by the line card, in dB. The larger the number, the higher the link’s tolerance to noise.
Up Attenuation – The signal attenuation detected by the line card, in dB. Generally, the larger the number, the longer the loop.
Current Link Up Time – The amount of time since the link became operational, in days, hours, minutes, and seconds.
Card Up Time – The amount of time since the line card was last reset, in days, hours, minutes, and seconds.
Link Down Count – The number of times the DSL link has gone down during the specified period.
Current Interval Counter – The amount of time elapsed in the current 15-minute interval.
DSL Link Performance Summary Screen – Models 8355 and 8375 B-B-D
Shows performance statistics for the DSL link at the physical layer.
Enter a port name (dsl1–dsl24) to see current statistics.
CPE Vendor ID – The manufacturer of the endpoint.
ATU-R/ATU-C Margin – The noise margin reported by the endpoint (ATU-R) or the line
card (ATU-C), in dB. The larger the number, the higher the link’s tolerance to noise.
ATU-R/ATU-C Attenuation – The signal attenuation repor ted by the endpoint (ATU-R) or the line card (ATU-C), in dB. Generally, the larger the number, the longer the loop.
ATU-R/ATU-C Transmit PowerThe transmit power level reported by the endpoint (ATU-R) or the line card (ATU-C), in dB.
Current Link Up Time – The amount of time since the link became operational, in days, hours, minutes, and seconds.
Card Up Time – The amount of time since the line card was last reset, in days, hours, minutes, and seconds.
ATU-R/ATU-C Current Tx Speeds – The current transmit DSL line speed in kbps for the endpoint (ATU-R) and the line card (ATU-C).
ATU-R/ATU-C Previous Tx Speeds – The transmit DSL line speed in kbps for the endpoint (ATU-R) and the line card (ATU-C) at the last rateChange trap, or if no rateChange trap has occurred, at line initialization.
ATU-R/ATU-C Attainable Speeds – The maximum attainable DSL line speed in kbps for the endpoint (ATU-R) and the line card (ATU-C) for the current configuration and line conditions.
ATU-R/ATU-C Relative Capacity – The operating speed for the endpoint (ATU-R) and the line card (ATU-C) relative to the attainable speed expressed as a percentage for the data path.
Table 4-2. Monitoring – Physical Ports (2 of 6)
Page 77
4. Monitoring
8335-A2-GB20-A0 March 2005
4-7
DSL Link Performance Summary Screen – Model 8365 B-B-D
Shows performance statistics for the DSL link at the physical layer.
Enter a port name (dsl1–dsl12) to see current statistics.
CPE Vendor ID – The manufacturer of the endpoint.
Latency – The channel used by the data stream, either Interleave or Fast path.
Line Code – The line code selected for the port either DMT, G.Lite, or ANSI.
Card Up Time – The amount of time since the line card was last reset, in days, hours,
minutes, and seconds.
Percent Link Up – The percentage of time the link has been up relative to the line card.
Operating Speeds – The DSL line speed in kbps for the downstream and upstream data
paths.
Down Margin – The margin reported by the endpoint, in dB. The larger the number, the higher the link’s tolerance to noise.
Down Attenuation – The signal attenuation reported by the endpoint, in dB. Generally, the larger the number, the longer the loop.
Up Margin – The margin detected by the line card, in dB. The larger the number, the higher the link’s tolerance to noise.
Up Attenuation – The signal attenuation detected by the line card, in dB. Generally, the larger the number, the longer the loop.
Current Link Up Time – The amount of time since the link became operational, in days, hours, minutes, and seconds.
Attainable Speeds – The attainable DSL line speed in kbps for the downstream and upstream data paths, based on the target margin selected and the Signal to Noise Ratio calculated at startup.
Relative Capacity – The operating speed relative to the attainable speed expressed as a percentage for the downstream and upstream data paths.
Table 4-2. Monitoring – Physical Ports (3 of 6)
Page 78
4. Monitoring
4-8 March 2005 8335-A2-GB20-A0
DSL Link Performance Summary Screen – Model 8385 B-B-D
Shows performance statistics for the DSL link at the physical layer.
Enter a port name (dsl1–dsl24) to see current statistics.
CPE Vendor ID – The manufacturer of the endpoint.
Down Margin – The margin reported by the endpoint, in dB. The larger the number, the
higher the link’s tolerance to noise.
Down Attenuation – The signal attenuation reported by the endpoint, in dB. Generally, the larger the number, the longer the loop.
Up Margin – The margin detected by the line card, in dB. The larger the number, the higher the link’s tolerance to noise.
Up Attenuation – The signal attenuation detected by the line card, in dB. Generally, the larger the number, the longer the loop.
Operating Speed – The DSL line speed in kbps for the downstream and upstream data paths.
Attainable Speed – The attainable DSL line speed in kbps for the downstream and upstream data paths, based on the target margin selected and the Signal to Noise Ratio calculated at startup.
Current Link Up Time – The amount of time since the link became operational, in days, hours, minutes, and seconds.
Card Up Time – The amount of time since the line card was last reset, in days, hours, minutes, and seconds.
Relative Capacity – The operating speed relative to the attainable speed expressed as a percentage for the downstream and upstream data paths.
Number of Repeaters in Loop – The sum of the number of repeaters in the loop (1– 8).
Table 4-2. Monitoring – Physical Ports (4 of 6)
Page 79
4. Monitoring
8335-A2-GB20-A0 March 2005
4-9
DSL Error Stats Screen – Models 8355 and 8375 B-B-F
Displays errors encountered on a selected port during the current 15-minute period, the previous 15-minute period, the previous hour, and the current day.
Enter a port name (dsl1–dsl24) to see current statistics.
ATU-R/ATU-C ES (Errored Seconds) – The number of errored seconds that have been encountered on the port. An errored second is a 1-second interval during which one or more of the following occurred: a Cyclic Redundancy Check (CRC) anomaly, one or more or Loss of Signal (LOS) defects, one or more Severely Errored Seconds (SES), or one or more Loss of Power (LOP) defects.
ATU-R/ATU-C SES (Severely Errored Seconds) – The number of Severely Errored Seconds (SESs) that have been encountered on the port. An SES is a 1-second interval during which 18 or more CRC anomalies, one or more LOS defects, one or more Severely Errored Frame Seconds (SEFS), or one or more Loss of Power (LOP) defects have occurred.
ATU-R/ATU-C UAS (Unavailable Seconds) – The number of 1-second intervals during which the DSL line is unavailable. The line becomes unavailable after 10 contiguous SESs or training. Once unavailable, it becomes available again after 10 contiguous seconds that include no SES after training.
ATU-R/ATU-C LOFS (Loss Of Frame Seconds) – The number of 1-second intervals for which a LOFS condition is declared after approximately 2.5 seconds of contiguous Severely Errored Frame (SEF) defects. A Loss Of Signal (LOS) overrides it. A LOFS is cleared after approximately 10 seconds with no SEF defect.
ATU-C LOSS (Loss of Signal Seconds) – The number of 1-second intervals during which a LOS condition has been declared on the DSL line. A LOS is declared when no response is received from the endpoint within 100 ms. The condition is cleared upon receipt of one good frame.
ATU-R Loss of Power Seconds – A count of the endpoint LOP failures detected at the line card (ATU-C). A LOP is defined as the receipt of 4 out of 6 dying-gasp messages from the endpoint.
Current Interval Counter – How much time has elapsed in the current 15-minute interval.
Table 4-2. Monitoring – Physical Ports (5 of 6)
Page 80
4. Monitoring
4-10 March 2005 8335-A2-GB20-A0
DSL Error Stats Screen – Model 8365 B-B-F
Displays errors encountered on a selected port during the current 15-minute period, the previous 15-minute period, the previous hour, and the current day.
Enter a port name (dsl1–dsl12) to see current statistics.
dn err secs, up err secs (Downstream and Upstream Errored Seconds) – The number of errored seconds that have been encountered on the port. An errored second is a 1-second interval during which one or more of the following occurred: a Cyclic Redundancy Check (CRC) error; Loss of Signal (LOS); Severely Errored Frame (SEF); or Loss of Power (LOP).
dn svr err sec, up svr err secs (Downstream and Upstream Severely Errored Seconds) – The number of Severely Errored Seconds (SESs) that have been encountered on the port. An SES is a 1-second interval during which 18 or more of the following occurred: a CRC error; LOS; SEF; or LOP.
dn unavail sec, up unavail sec (Upstream and Downstream Unavailable Seconds) – The number of 1-second intervals during which the DSL line is unavailable. The line becomes unavailable after 10 contiguous SESs. Once unavailable, it becomes available again after 10 contiguous seconds that include no SES.
Link Down Count – The number of times the link has gone down.
SN loss of power – The number of LOPs reported. LOP is declared upon receipt of four
“dying gasp” messages from the remote unit.
Current Interval Counter – How much time has elapsed in the current 15-minute interval.
DSL Error Stats Screen – Model 8385 B-B-F
Displays errors encountered on a selected port during the current 15-minute period, the previous 15-minute period, the previous hour, and the current day.
Enter a port name (dsl1–dsl24) to see current statistics.
dn err secs, up err secs (Downstream and Upstream Errored Seconds) – The number of errored seconds that have been encountered on the port. An errored second is a 1-second interval during which one or more of the following occurred: a Cyclic Redundancy Check (CRC) error or Loss of Sync Word (LOSW).
dn svr err sec, up svr err secs (Downstream and Upstream Severely Errored Seconds) – The number of Severely Errored Seconds (SESs) that have been encountered on the port. An SES is a 1-second interval during which 50 or more CRC errors or one or more LOSW defects occurred.
dn unavail sec, up unavail sec (Upstream and Downstream Unavailable Seconds) – The number of 1-second intervals during which the DSL line is unavailable. The line becomes unavailable after 10 contiguous SESs. Once unavailable, it becomes available again after 10 contiguous seconds that include no SES.
dn CRC Anomalies, up CRC Anomalies (Downstream and Upstream CRC Anomalies) – The number of CRC anomalies that have occurred during the accumulation period.
dn LOSW sec, up LOSW sec (Downstream and Upstream Loss of Sync Word Seconds) – The number of 1-second intervals during which one or more LOSW defects are declared during the accumulation period.
Link Down Count – The number of times the link has gone down.
Current Interval Counter – How much time has elapsed in the current 15-minute interval.
Table 4-2. Monitoring – Physical Ports (6 of 6)
Page 81
4. Monitoring
8335-A2-GB20-A0 March 2005
4-11
Monitoring ATM Activity
Use the ATM Switch screens to display read-only system information about ATM parameters, cross connections, and activity.
Procedure
To view the ATM Switch menu:
1. Follow this menu selection sequence:
MonitoringATM Switch (B-E)
2. The ATM Switch menu appears. Select the submenu option as shown in
Table 4-3, Monitoring – ATM Switch, and press Enter.
Table 4-3. Monitoring – ATM Switch (1 of 7)
ATM Parameters Screen Models 8335, 8365, 8375, and 8385 B-E-A
Displays parameters selected for ATM.
rt-VBR and nrt-VBR CAC Percent Bandwidth Utilization – The values represent the amount of oversubscription the Connection Admission Control algorithm allows for the class of service.
Uncorrected HEC Count – If the number of HEC errors (0 to 1000) exceeds the selected number within a 15-minute period, an SNMP trap is sent. If Uncorrected HEC Count is set to Disable, no trap is ever sent.
OCD Event Count – If the number of OCD errors exceeds the selected number within a 15-minute period, an SNMP trap is sent. If OCD Event Count is set to Disable, no trap is ever sent.
ATM Parameters Screen Model 8355 B-E-A
Displays parameters selected for ATM.
Uncorrected HEC Count – If the number of HEC errors (0 to 1000) exceeds the selected number within a 15-minute period, an SNMP trap is sent. If Uncorrected HEC Count is set to Disable, no trap is ever sent.
Page 82
4. Monitoring
4-12 March 2005 8335-A2-GB20-A0
ATM Cross Connect Screen Models 8335 and 8385 B-E-B
Displays ATM cross connections.
VPI – The VPI of this connection.
VCI – The VCI of this connection.
Profile Name – The traffic profile used for this connection.
Status – The status of this connection. It is one of:
Up – The VPI/VCI connection is operational.
Down – The VPI/VCI connection is not operational.
CSN – The Connection Serial Number associated with this connection, for example 02S06:000, where 02 is the slot number, S is the type of connection (Standard or Custom), 06 is the card port number, and 000 is a sequence number generated by the system.
Total Connections for this Interface – The number of connections defined to the ATM uplink for this interface.
Available Connections – Shows how many more connections may be defined on this line card (maximum 250 per card).
ATM Cross Connect Screen Models 8355 and 8375 B-E-B
Displays ATM cross connections.
VPI – The VPI of this connection.
VCI – The VCI of this connection.
Tx Profile – The downstream traffic profile used for this connection.
Rx Profile – The upstream traffic profile used for this connection.
Status – The status of this connection. It is one of:
Up – The VPI/VCI connection is operational.
Down – The VPI/VCI connection is not operational.
Seg Endpt – Defines whether the connection will act as a segment endpoint for ATM OAM loopbacks as defined in ITU I.610.
CSN – The Connection Serial Number associated with this connection, for example 02S06:000, where 02 is the slot number, S is the type of connection (Standard or Custom), 06 is the card port number, and 000 is a sequence number generated by the system.
Total Connections For This Interface – The number of connections defined to the ATM uplink for this interface.
Available Connections – Shows how many more connections may be defined on this line card (maximum 64 per card).
Table 4-3. Monitoring – ATM Switch (2 of 7)
Page 83
4. Monitoring
8335-A2-GB20-A0 March 2005
4-13
ATM Cross Connect Screen – Model 8365 B-E-B
Displays ATM cross connections.
VPI – The VPI of this connection.
VCI – The VCI of this connection.
Dnstream Profile – The downstream traffic profile used for this connection.
Upstream Profile – The upstream traffic profile used for this connection.
Status – The status of this connection. It is one of:
Up – The VPI/VCI connection is operational.
Down – The VPI/VCI connection is not operational.
CSN – The Connection Serial Number associated with this connection, for example 02S06:000, where 02 is the slot number, S is the type of connection (Standard or Custom), 06 is the card port number, and 000 is a sequence number generated by the system.
Total Connections For This Interface – The number of connections defined to the ATM uplink for this interface.
Available Connections – Shows how many more connections may be defined on this line card (maximum 250 per card).
Table 4-3. Monitoring – ATM Switch (3 of 7)
Page 84
4. Monitoring
4-14 March 2005 8335-A2-GB20-A0
ATM Traffic Profiles Screen – Models 8335, 8365, 8375, and 8385 B-E-C
Displays the characteristics of the default and custom ATM traffic profiles. To scroll to the previous or next group of profiles, type u (for Up) or d (for Down) in the Index field. Enter 0 to add a new profile. See Configuring ATM Traffic Profiles in Chapter 3, Configuration for more information if you are adding a new traffic profile.
Profile Name – The default name or name specified for a traffic profile. Enter a space to delete an existing entry.
Class – Displays the class of service for the profile. It is one of:
CBR – Constant Bit Rate.
rt-VBR – Real-time Variable Bit Rate.
nrt-VBR – Non-real-time Variable Bit Rate.
UBR – Unspecified Bit Rate.
PD – Shows by Y for Yes or N for No whether the profile supports Early Packet Discard and Partial Packet Discard.
POL – Displays the policing mode. It is one of:
N – None. All cells are forwarded to the SCM.
T – Tag. All cells are forwarded to the SCM, but nonconforming cells (cells which do
not comply with the traffic contract) have their Cell Loss Priority bits set to 1.
D – Drop. Nonconforming cells are dropped.
PCR – Displays the Peak Cell Rate. This field is not editable when Class is set to UBR.
CDVT – Displays the Cell Delay Variation Tolerance, in tenths of microseconds. This field
is not editable when Class is set to UBR.
SCR – Displays the Sustained Cell Rate. This field is not editable when Class is set to UBR.
MBS – Displays the Maximum Burst Size. This field is not editable when Class is set to UBR.
Total Profiles – Displays how many profiles have been defined (used to determine the range of indexes available for display).
See Table 3-2, Conversion Guidelines in Chapter 3, Configuration, for information about converting cells per second to kbps.
Table 4-3. Monitoring – ATM Switch (4 of 7)
Page 85
4. Monitoring
8335-A2-GB20-A0 March 2005
4-15
ATM Traffic Profiles Screen – Model 8355 B-E-C
Displays the characteristics of the default and custom ATM traffic profiles. To scroll to the previous or next group of profiles, type u (for Up) or d (for Down) in the Index field. Enter 0 to add a new profile. See Configuring ATM Traffic Profiles in Chapter 3, Configuration for more information if you are adding a new traffic profile.
Profile Name – The default name or name specified for a traffic profile. Enter a space to delete an existing entry.
Class – Displays the class of service for the profile:
UBR – Unspecified Bit Rate.
PD – Shows Y for Yes or N for No whether the profile supports Early Packet Discard and Partial Packet Discard.
Total Profiles – Displays how many profiles have been defined (used to determine the range of indexes available for display).
See Table 3-2, Conversion Guidelines in Chapter 3, Configuration, for information about converting cells per second to kbps.
Table 4-3. Monitoring – ATM Switch (5 of 7)
Page 86
4. Monitoring
4-16 March 2005 8335-A2-GB20-A0
ATM Aggregate Statistics Screen B-E-D
Displays statistics for the selected interface.
Interface Name – Select the name of the interface (dsl1:1 through dsl16:1 on the Model 8335, dsl1:1 through dsl12:1 on the Model 8365, or dsl1:1 through dsl24:1 on the Model 8355, 8375 and 8385).
Total Cells Received – Total number of ATM cells received from the endpoint.
Total Rx Cells Dropped – Total number of ATM cells received by the line card that were
dropped due to policing or congestion.
Total Cells Sent – Total number of ATM cells sent to the endpoint.
Total TX Cells Dropped – Total number of ATM cells that would have been sent to the
endpoint that were dropped due to congestion.
Corrected HEC – Number of cells from the customer premises equipment whose headers were corrected by the line card (Model 8335 only).
Uncorrected HEC – Number of cells from the customer premises equipment whose headers contained multiple errors and were dropped.
OCD Events – Number of Out of Cell Delineation events on the link from the customer premises equipment.
Unknown Cells – Number of cells with an unknown VPI and VCI.
VCC Performance Statistics Screen B-E-E
Displays statistics for the selected Virtual Channel Connection (VCC).
Interface Name – Select the name of the interface (dsl1:1 through dsl16:1 on the Model 8335, dsl1:1 through dsl12:1 on the Model 8365, or dsl1:1 through dsl24:1 on the Model 8355, 8375, and 8385).
VPI – Virtual Path Identifier of the VCC.
VCI – Virtual Channel Identifier of the VCC.
Class – Class of service for this VCC: CBR, rt-VBR, nrt-VBR, or UBR.
Total Cells Received – Total number of ATM cells received from the endpoint.
Total Rx Cells Dropped – Total number of ATM cells received by the line card that were
dropped due to policing or congestion.
Total Cells Sent – Total number of ATM cells sent to the endpoint.
Total TX Cells Dropped – Total number of ATM cells that would have been sent to the
endpoint or SCM that were dropped due to congestion.
Corrected HEC – Number of cells received whose headers were corrected by the line card (Model 8335 only).
Uncorrected HEC – Number of cells received whose headers contained multiple errors and were dropped.
OCD Events – Number of Out of Cell Delineation events on the connection.
Unknown Cells – Number of cells with an unknown VPI and VCI.
Table 4-3. Monitoring – ATM Switch (6 of 7)
Page 87
4. Monitoring
8335-A2-GB20-A0 March 2005
4-17
Unknown Cell Log Screen B-E-F
Displays records for up to 100 unknown cell events.
Select an interface to position the list of events, or select an Action:
N to return to Interface Name field,
C to clear the entire unknown cell log (clears the log for all interfaces),
U to scroll up one page towards newer entries, or
D to scroll down one page towards older entries.
Interface Name – Select the name of the interface (dsl1:1 through dsl16:1 on the Model 8335, dsl1:1 through dsl12:1 on the Model 8365, or dsl1:1 through dsl24:1 on the Model 8355, 8375, and 8385).
VPI – Virtual Path Identifier of the cell.
VCI – Virtual Channel Identifier of the cell.
Time – Month, day, and time the unknown cell was received.
ATM Connection Status Screen B-E-G
One or two connections’ statistics can been monitored (VC1/VC2), which are defined by their Interface/VPI/VCIs. Either connection can be for a DSL interface or for the WAN interface to the SCM card.
To view the entire data path flow through to the line card, you must configure the VC1 connection to be a DSL interface. Then, enter wan1:1 for the VC2 connection. VC1 will show data being received from and sent to the endpoint, while VC2 will show data being sent to/from the SCM card.
NOTE: For the DSL interface, cells are “sent” downstream from the line card to the endpoint. For the WAN interface, cells are “sent” from the ATM bus to the SCM card.
Interface Name – Select the name of the DSL interface (dsl1:1 through dsl16:1 on the Model 8335, dsl1:1 through dsl12:1 on the Model 8365, or dsl1:1 through dsl24:1 on the Model 8355, 8375, or 8385), or enter wan1:1 for the WAN interface (ATM bus to the SCM card).
VPI – Enter the VPI of the connection you wish to display, from 0 to 15. For the DSL interface, the VPI is the external value that is also set in the endpoint. For the WAN interface, VPI is the internal value for the internal connection between the line card and the SCM card.
VCI – Enter the VCI of the connection you wish to display, from 32 to 255. For the DSL interface, the VCI is the external value that is also set in the endpoint. For the WAN interface, VCI is the internal value for the internal connection between the line card and the SCM card.
Current Interval Counter – Displays the amount of time that has elapsed in the current 15-minute interval.
Table 4-3. Monitoring – ATM Switch (7 of 7)
Page 88
4. Monitoring
4-18 March 2005 8335-A2-GB20-A0
Monitoring SN Information
Use the SN Information screens to display read-only system information about Service Node.
Procedure
To view SN information:
1. Follow this menu selection sequence:
MonitoringSN Information (B-F)
2. The Monitor SN menu appears. Select the submenu option as shown in
Table 4-4, Monitoring – SN Information, and press Enter.
Page 89
4. Monitoring
8335-A2-GB20-A0 March 2005
4-19
Table 4-4. Monitoring – SN Information
SN Information Screen B-F-A
Displays parameters selected for the SN as retrieved from the Paradyne Enterprise MIB and the endpoint. If the information cannot be obtained from the endpoint, the field displays N/A.
Interface Name – Select the name of the interface (dsl1:1 through dsl16:1 on the Model 8335, dsl1:1 through dsl12:1 on the Model 8365, or dsl1:1 through dsl24:1 on the Model 8375 or 8385).
Name – Name assigned to the endpoint.
Contact – Name or number of the person responsible for the endpoint (Models 8335,
8365, 8375, and 8385 only).
Location – Physical location of the system (Models 8335, 8365, 8375, and 8385 only).
Circuit ID – Location of the circuit (Models 8335, 8365, 8375, and 8385 only).
Model Number – Model number of the endpoint (Models 8335, 8375, and 8385 only).
Serial Number – Serial number of the endpoint (Models 8335, 8355, 8375, and 8385
only).
Firmware Rev – Version of firmware.
Vendor ID – The 4-character vendor ID of the SN (Models 8355, 8365, and 8385 only).
ITU Standard Rev – Populated by the ITU standard revision number of G.994.1
(Model 8385 only).
Service Node Management Screen (Models 8335 and 8385 Only B-F-B
For Models 8335 and 8385, displays the SN management connection. To scroll to the previous or next group of profiles, type U (for Up) or D (for Down) in the Index field.
NOTE: Data is routed from the MCP card through the line card to the endpoint. Each DSL link to the endpoint can run at speeds greater than that of the management bus between the MCP card and the line card, possibly overloading the management bus very quickly. Therefore, it is recommended that only one file transfer be in process at a time.
Interface – The name of the interface (dsl1:1 through dsl16:1 on the Model 8335 or dsl1:1 through dsl24:1 on the Model 8385).
IP Address – The IP Address that the DSL provider will use to manage the endpoint through power resets.
Subnet Mask – The subnet mask that the DSL provider will use to manage the endpoint.
VPI – The VPI of the connection.
VCI – The VCI of the connection.
Page 90
4. Monitoring
4-20 March 2005 8335-A2-GB20-A0
Front Panel LEDs
The following table describes the meaning and states of the LEDs on the front panel.
Type LED LED is . . . *
* Pulsing: LED turns off momentarily once per second.
Slow Blinking: LED turns on momentarily once per second. Fast Blinking: LED turns off and on in equal duration 4 times per second.
Indicating . . .
SYSTEM OK Green, On
Off
Green, Pulsing
Green, Fast Blinking
Card failure. System processing functions have stopped.
No power to card.
Card functioning normally.
Firmware download needed.
Alrm Amber, On
Off
Alarm is present on the card. ATM interface is not being detected.
Normal operation, no alarms.
Tes t A mb e r, O n
Off
Amber, Fast Blinking
Test in progress.
Normal operation, no tests.
Self-test is in progress.
ATM BU S TX Of f
Green, Fast Blinking
Inactive.
Cells are being transmitted.
RX Off
Green, Fast Blinking
Inactive, link down.
Cells are being received.
LOC Amber, On
Off
Loss Of Clock. ATM bus clock signal is not present.
Normal operation.
DSL PORT
8335
8365
8355, 8375, 8385
1/9– 8/16
1–12
1/13–12/24
Green, On
Off
Green, Slow Blinking
Green, Fast Blinking
Good signal, unit is trained.
Port is disabled.
Port is in test, or is down.
Port is training.
ALT BANK
8335
8355, 8375, 8385
9–16 1–8
13–24 1–12
Off
Amber, Fast Blinking
The ports not currently displayed by the port status LEDs are functioning normally or are disabled.
One of the ports not currently being displayed by the port status LEDs is down, in test, or in training mode.
00-16661
AT M
SDSL
8335
SYSTEM
OK
Alrm
Test
TX
RX
LOC
1/9
2/10
3/11
4/12
ATM BUS
DSL PORT
5/13
6/14
7/15
8/16
PORT
9/21
10/22
11/23
12/24
PORT
ALT BANK
9-16
1-8
00-16661
AT M
SDSL
8335
SYSTEM
OK
Alrm
Test
TX
RX
LOC
1/9
2/10
3/11
4/12
ATM BUS
DSL PORT
5/13
6/14
7/15
8/16
PORT
9/21
10/22
11/23
12/24
PORT
ALT BANK
9-16
1-8
00-16719
G.DMT
G.Lite
8365
SYSTEM
OK
Alrm
Test
TX
RX
LOC
1
2
3
4
ATM BUS
DSL PORT
5
6
7
8
PORT
9
10
11
12
01-16986
AT M
SHDSL
8385
SYSTEM
OK
Alrm
Test
TX
RX
LOC
1/13
2/14
3/15
4/16
ATM BUS
DSL PORT
5/17
6/18
7/19
8/20
PORT
9/21
10/22
11/23
12/24
PORT
ALT BANK
13-24
1-12
02-17210
AT M
ReachDSL
8355
SYSTEM
OK
Alrm
Test
TX
RX
LOC
1/13
2/14
3/15
4/16
ATM BUS
DSL PORT
5/17
6/18
7/19
8/20
PORT
9/21
10/22
11/23
12/24
PORT
ALT BANK
13-24
1-12
Page 91
8335-A2-GB20-A0 March 2005 5-1
5
Diagnostics
Overview
The ATM Line Card provides the following diagnostic tools:
Self-Test on page 5-2
— Tests the hardware components of the card, the results of which can be
displayed on the Selftest screen.
Alarms on page 5-4
— Displays the alarm conditions that have been detected.
AT M Pi ng on page 5-11
— Sends OAM F5 loopback cells to the remote end of the ATM virtual circuit.
A summary of all active ping tests is also available.
Loopback Test (Model 8385 Only) on page 5-15
— Performs Loopback test on the SHDSL span of the network for
Model 8385 cards.
Page 92
5. Diagnostics
5-2 March 2005 8335-A2-GB20-A0
Self-Test
Use the Selftest screen to view the results of the last self-test performed when the card was powered on or reset.
Procedure
To view the results of the last self-test:
1. Follow this menu selection sequence:
DiagnosticsSelftest (D-A)
The Selftest screen appears.
2. Interpret the display as shown in Table 5-1, Monitoring – Selftest.
Page 93
5. Diagnostics
8335-A2-GB20-A0 March 2005
5-3
Table 5-1. Monitoring – Selftest
Selftest Screen D-A
Displays the results of the self-test executed the last time the card was powered on or reset. Except for the DSL port loopback, all test results are displayed as Pass or Fail.
Device results:
RAM – Random Access Memory test result.
HDLC Bus – Verifies that the HDLC bus is operational.
File System – Verifies that the file systems’ nonvolatile memory devices (SEEP, Flash,
and/or NVRAM) are operational.
FPGA – Verifies that the Field Programmable Gate Array (FPGA) is operational.
ATM Cross Connects – Verifies that the ATM cross connect interface device is
operational.
Backplane Interface – Verifies that the line card backplane interface device is operational by exercising the hardware and software components that control the interface between the line card and the ATM uplink.
External Interrupt – Verifies external interrupt operation (for Models 8355 and 8385 only).
AAL5 SAR – Verifies that the Segmentation And Reassembly circuit is operational.
DSL – DSL port loopback test results. A result code is shown for each port: P for Pass,
F for Fail, N for Not Available, or D for Disabled.
Page 94
5. Diagnostics
5-4 March 2005 8335-A2-GB20-A0
Alarms
Use the Card Alarms screen to determine if any alarm conditions have been detected.
Procedure
To view the alarms:
1. Follow this menu selection sequence:
DiagnosticsAlarms (D-B)
The Card Alarms screen appears.
2. Interpret the display as shown in Table 5-2, Monitoring – Card Alarms.
Page 95
5. Diagnostics
8335-A2-GB20-A0 March 2005
5-5
Table 5-2. Monitoring – Card Alarms (1 of 6)
Card Alarms Screen – Model 8335 D-B
Displays alarms for the card and port levels. Columns on this screen represent port numbers (01–16).
Major Alarms:
Selftest – Shown as Pass or Fail.
ATM Bus Failure – If ALARM appears on this line, there has been a Loss Of Clock (LOC)
because the line card is unable to communicate with the SCM. This could be because the chassis does not support the ATM bus (the chassis is not an 8620 or 8820 BLC), or the SCM card has been removed from the chassis.
DSL Port Selftest Fail – DSL port self-test results. A result code is shown for each port: P for Pass or F for Fail.
Minor Alarms:
Config Error – If ALARM appears on this line, the card has detected a checksum error in
the memory where the configuration is stored.
Loss of Cell Delineation – If a loss of cell delineation has been detected on the port, an A (for Alarm) appears in the column for that port.
Loss of Signal – If a loss of signal has been detected on the port, an A (for Alarm) appears in the column for that port.
CAC Exceeded – The DSL line rate has dropped below the traffic contract. The traffic contract has exceeded the available bandwidth making the contract invalid.
Page 96
5. Diagnostics
5-6 March 2005 8335-A2-GB20-A0
Card Alarms Screen – Model 8355 and Model 8375 D-B
Displays alarms for the card and port levels. Columns on this screen represent port numbers (01– 24). If Next appears, press Enter to display the next 12 ports (13–24); if Previous appears, press Enter to display previous page of ports (01–12).
Major Alarms:
Selftest – Shown as Pass or Fail.
DSL Port Selftest Failure – DSL port self-test results. A result code is shown for each
port: P for Pass or F for Fail.
Initialization Failure – The DSL link has failed to initialize due to one of the following:
Data Init Failure – No ACK is received form sending configuration information to the
peer ATU.
Configuration Init Failure – The peer ATU cannot support the configuration.
Protocol Init Failure – The peer ATU is incompatible.
ATM Bus Failure – If ALARM appears on this line, there has been a Loss Of Clock (LOC) because the line card is unable to communicate with the SCM. This could be because the chassis does not support the ATM bus (the chassis is not an 8620 or 8820 BLC), or the SCM card has been removed from the chassis.
(Continued on next page)
Table 5-2. Monitoring – Card Alarms (2 of 6)
Page 97
5. Diagnostics
8335-A2-GB20-A0 March 2005
5-7
Card Alarms Screen – Model 8355 and Model 8375 (Continued) D-B
Minor Alarms:
Config Error – If ALARM appears on this line, the card has detected a checksum error in
the memory where the configuration is stored.
Loss of Cell Delineation – If a loss of cell delineation has been detected on the port, an A (for Alarm) appears in the column for that port.
Loss of Signal – If a loss of signal has been detected on the port, an A (for Alarm) appears in the column for that port.
Loss of Power – The endpoint (ATU-R) has lost power.
Loss of Frame – A Loss Of Frame (LOF) condition exists. A LOF is declared after
approximately 2 seconds of contiguous Severely Errored Frames (SEF).
Loss of Signal Quality – A Loss of Signal Quality (LOSQ) condition exists. A LOSQ condition exists when the noise margin falls below the minimum noise margin (0 dB) or the BER exceeds 10
-7
for 3 seconds, or when the rate falls below the minimum configured
rate for 3 seconds.
Error Seconds Threshold –The number of Errored Seconds has exceeded the user-defined threshold.
Severely Errored Seconds Threshold – The number of Severely Errored Seconds has exceeded the user-defined threshold.
Unavailable Seconds Threshold – The number of Unavailable Seconds has exceeded the user-defined threshold.
Increasing Rate Threshold – The current rate is the previous rate plus the user-defined threshold.
Decreasing Rate Threshold – The current rate is the previous rate plus the user-defined threshold.
Table 5-2. Monitoring – Card Alarms (3 of 6)
Page 98
5. Diagnostics
5-8 March 2005 8335-A2-GB20-A0
Card Alarms Screen – Model 8365 D-B
Displays alarms for the card and port levels. Columns on this screen represent port numbers (01–12).
Major Alarms:
Selftest – Shown as Pass or Fail.
ATM Bus Failure – If ALARM appears on this line, there has been a Loss Of Clock (LOC)
because the line card is unable to communicate with the SCM. This could be because the chassis does not support the ATM bus (the chassis is not an 8620 or 8820 BLC), or the SCM card has been removed from the chassis.
DSL Port Selftest Fail – DSL port self-test results. A result code is shown for each port: P for Pass or F for Fail.
Minor Alarms:
Config Error – If ALARM appears on this line, the card has detected a checksum error in
the memory where the configuration is stored.
Loss of Cell Delineation – If a loss of cell delineation has been detected on the port, an A (for Alarm) appears in the column for that port.
Loss of Signal – If a loss of signal has been detected on the port, an A (for Alarm) appears in the column for that port.
The following alarms are monitored in both the downstream and upstream direction except for SN Loss of Power (upstream only) and CAC Exceeded (upstream only):
Error Seconds – The number of Errored Seconds has exceeded the user-defined threshold.
Severely Errored Seconds – The number of Severely Errored Seconds has exceeded the user-defined threshold.
Unavailable Seconds – The number of Unavailable Seconds has exceeded the user-defined threshold.
SN Loss of Power – The endpoint has lost power.
Table 5-2. Monitoring – Card Alarms (4 of 6)
Page 99
5. Diagnostics
8335-A2-GB20-A0 March 2005
5-9
Card Alarms Screen – Model 8385 D-B
Displays alarms for the card and port levels. Columns on this screen represent port numbers (01– 24). If Next appears, press Enter to display the next 12 ports (13–24); if Previous appears, press Enter to display previous page of ports (01–12).
Major Alarms:
Selftest – Shown as Pass or Fail.
ATM Bus Failure – If ALARM appears on this line, there has been a Loss Of Clock (LOC)
because the line card is unable to communicate with the SCM. This could be because the chassis does not support the ATM bus (the chassis is not an 8620 or 8820 BLC), or the SCM card has been removed from the chassis.
DSL Port Selftest Failure – DSL port self-test results. A result code is shown for each port: P for Pass or F for Fail.
(Continued on next page)
Table 5-2. Monitoring – Card Alarms (5 of 6)
Page 100
5. Diagnostics
5-10 March 2005 8335-A2-GB20-A0
Card Alarms Screen – Model 8385 (Continued) D-B
Minor Alarms:
Config Error – If ALARM appears on this line, the card has detected a checksum error in
the memory where the configuration is stored.
Loss of Cell Delineation – If a loss of cell delineation has been detected on the port, an A (for Alarm) appears in the column for that port.
Loss of Signal – If a loss of signal has been detected on the port, an A (for Alarm) appears in the column for that port.
Error Seconds –The number of Errored Seconds has exceeded the user-defined threshold.
Severely Errored Seconds – The number of Severely Errored Seconds has exceeded the user-defined threshold.
Unavailable Seconds – The number of Unavailable Seconds has exceeded the user-defined threshold.
Loss of Sync Word Second – The number of Loss of Sync Word (LOSW) seconds has exceeded the user-defined threshold.
CRC Anomalies Threshold – The number of CRC anomalies has exceeded the user-defined threshold.
SNR Margin Threshold – The SNR margin has exceeded the user-defined threshold.
Attenuation Threshold – The current value reached or dropped below the user-defined
threshold.
Repeater Segment Down – One of the repeater segments is down.
SN Loss of Power – The endpoint has lost power.
CAC Exceeded – The DSL line rate has dropped below the traffic contract. The traffic
contract has exceeded the available bandwidth making the contract invalid.
Table 5-2. Monitoring – Card Alarms (6 of 6)