Paradyne FrameSaver NP 100, FrameSaver NP 64+, FrameSaver NP 110, FrameSaver NP 120 Installation Quick Reference Manual

Page 1
FrameSaver® NP
Installation & Quick Reference Guide
FrameSaver NP Models 64+, 100, 110 and 120
Document Number 980-000-0272B August 2000
This Quick Reference Guide provides an over view on how to inst all a FrameSaver NP Model 64+, 100, 110 or 120 unit. This includes making the physical connections be­tween the unit, netw ork, DTE device(s), and telephone line. It also tells you ho w to find more detailed information about your FrameSaver NP.
Product Documentation on the World Wide Web
We provide complete product documentation online. This lets you search the docu­mentation for specific topics and print only what you need, reducing the waste of sur­plus printing. It also helps us provide timely product update information and maintain competitive prices for our products.
Complete documentation for these products is available at
www.paradyne.com
.
Select Library
Technical Manuals →
FrameSaver NP (NetPath) Frame Relay Digital Access Units
Select the appropriate document from the documentation list:
FrameSaver NP 64+ User’s Manual - Installat ion Guide, Publicatio n # 980-001- 0221 FrameSaver NP 100 U s er’s M an ual - Installatio n G u id e , P ub licati o n # 980-001-0210 FrameSaver NP 110 U s er’s M an ual - Installatio n G u id e, P ub l ication # 980-001- 024 0 FrameSaver NP 120 U s er’s M an ual - Installatio n G u id e, P ub l ication # 980-001- 023 0
116
Page 2
Getting Started
Before installing or starting to use the FrameSaver NP, you shou ld:
Install the User’s Manual - Installation Guide so that you can access all the installation, configuration, and operating information about the unit.
Print sections you may want to reference.
User’s Manual - Installation Guide
The manual is in PDF fil e format. Your PC shou ld be using Micros oft Windows 3.1 or above, and have Adobe Acr obat Reader inst alled for brows ing or printing this manual.
Adobe Acrobat Reader may be obtained free fro m Adobe Systems Incor porated, from their Web Site at www.adobe.com.
Using Adobe Acrobat Reader
Adobe Acrobat Reader is used just as you would most word processing or text editing programs. Start Adobe Acrobat Reader and open the file containing the FrameSaver NP User’s Manual - Installation Guide. You can simply scroll through the pages, or use the Bookmarks along the left side to move around the manual or the tables in the front of the manual.
To print the manual or a selection of pages, select Print... from the F
ile menu and then
select the range of pages you wish to print. Select OK to begin printing.
Ordering a Hard Copy of the User’s Manual
Contact Paradyne Corporation at the address on the back of this Guide to ob tain a print­ed copy of a FrameSa ver NP User’s Manual - Installation Guide. Always specify the “latest revision” for each publication number:
Safety Instructions
Before proceeding with the installation, carefully rea d the Equipment I nterference No­tice, Important Safety Instructions and Preface s ections of the FrameSaver NP User’s Manual - Installation Guide.
Contact your service representative, distr ibutor or s ales repres entative to ord er cables .
T1 or DSX network cable, RJ-48, twisted pair 135-982-0006 Dial Line (POTS) cable, RJ-11 connector 135-007-7200 ISDN BRI network cable, RJ-49 connector 135-981-0006 Console cable (to AUX2), DB-9 connector 135-000-0464 Console cable (to AUX2), D B -25 connector 135-007-0400 AUX Port to router console port cable, DB-25 connector 135-008-0400 AUX Port to Cisco router console port, RJ-45 type connector 135-990-0006
2
Page 3
Before You Begin
Ensure you have the following:
A dedicated, grounded, circuit breaker p rotected power outlet within six feet o f the FrameSaver NP unit.
A suitable location for the unit that is clean, well-lit, ventilate d and free fro m environmental extremes.
One to two feet of clearance for cable connections to the unit.
Package Checklist
Verify that the packaging contains the following:
FrameSaver NP unit
Unit power cord or AC Power Pack with cord
If ordered, optional wall-mount or rack-mount bracket assembly.
In addition, you will need Input/Output cables if not already supplied. These cables are listed for each FrameSaver NP Model on pages 13 - 15 of this guide.
Mounting the FrameSaver NP
FrameSaver NP units come equipped with rubber feet for table or shelf-top placemen t. Optional adapter brackets are available for wall mounting (Model 64+ includes wall­mount key-holes in its base) and standard 19" or 24" rack mounting. To attach and mount adapter brackets, follow the instructions supplied with the mounting adapters.
Allow sufficient space for cooling and access to the front panel indicators for trouble­shooting in all installations.
Page 4
Power Up a FrameSaver NP 64+
Make Power Connections
1. Plug the 2-pin keyed and locking connector at the end of the cord from the AC Power Pack into the right-most pins of the 4-pin Power Connector located on the rear of the FrameSaver NP 64+, just to the right of the alert marking.
CAUTION
The power connectors are keyed and fit easily together when oriented correctly with the locking clip toward the top of the unit. Do not force the connectors together.
CAUTION
The 2-pin keyed plug fits easily into the two RIGHT-SIDE pins of the 4-pin Power Connector, and must only be inserted there. The FrameSaver NP unit will be damaged if the plug is forced into the other side.
Contact your service representative, distr ibutor or s ales repres entative to ord er cables .
DATA PORT
SEE
USERS
MANUAL
POWER
PAC
O N
1234 5 6 7 8 9 101112
DLCI
x1x100 x10
DIGITS
2-Pin
Connector
from
Power Pack
Plug into RIGHT side
Pins ONLY
Blocking Safety Plug
(Remove only when insta lling optional
Power Control Unit)
DDS network cable, RJ-48, twisted pair 135-982-0006 Dial Line (POTS) cable, RJ-11 connector 135-007-7200 ISDN BRI network cable, RJ-49 connector 135-981-0006 EIA-232 Data Port (DTE) cable 135-000-0400 EIA-530 Data Port (DTE) cable 135-002-0400 EIA-530A Data Port (DTE) cable 135-003-0400 ITU-X.21-NS Data Port (DTE) cable 135-005-0400 ITU-V.35 Data Port (DTE) cable 135-001-0400 ITU-V.35 Data Port (DTE) cable to Cisco router serial port,
HD-60 connector Console cable (to AUX2), DB-9 connector 135-000-0464 Console cable (to AUX2), D B -25 connector 135-007-0400 AUX Port to router console port cable, DB-25 connector 135-008-0400 AUX Port to Cisco router console port, RJ-45 type connector 135-990-0006
Page 5
2. Plug the Power Pac at the other end of the power cord into an AC outlet.
3. The unit will go through the following power-up sequence:
FrameSaver NP 64+ Power-Up Sequence
If the LED indicat ions ar e not as describ ed above , ref er to S ection 5, “Diag nostics” of the FrameSaver NP 64+ User’s Manual - Installation Gu ide.
If operation l ooks normal, u nplug the FrameSaver NP befo re making inpu t/output con ­nections.
If an optional Power Control Unit (PCU) is to be installed with this FrameSaver NP, refer to the instructions provided with the PCU and install it now.
Proceed to Making Network and Input/Output Connections on page 9 of this guide.
Basic FrameSaver NP 64+ FrameSaver NP 64+ with ISDN
POWER LED l ights and stays on.
READY LED may flash several times, then remain OFF during self-test (approxi mately 45 seconds).
READY and ISDN READY LEDs may flash several times, then remain OFF during self-test (approximately 45 seconds).
READY LED is ON steady after completion of self-test.
READY and ISDN READY LEDs are ON steady after completion of self-test.
The DDS ALARM and FR MGMT. LEDs should not be flashing together. All other LED indications should be ignored at this time.
512
Page 6
Power Up a FrameSaver NP 100
Power Connections
1. Plug the IEC 320 end of the Power Cord into the connector on the rear of the FrameSaver NP.
2. Plug the other end of the Power Cord into an AC outlet.
3. The unit will go through the following power-up sequence
FrameSaver NP 100 Power-Up Sequence
If the LED indicat ions ar e not as de scribed above, r efer to Secti on 5, “Diagno stics ” of the FrameSaver NP 100 User’s Manual - Installation Guide. If operation looks nor- mal, unplug the FrameSaver NP before making input/output connections.
If an optional Power Control Unit (PCU) is to be installed with this FrameSaver NP, refer to instructions provided with the PCU and inst all it now.
Proceed to Making Network and Input/Output Connections on page 9 of this guide.
FrameSaver NP 100 (120) Specifications
Basic FrameSaver NP 100 FrameSaver NP 100 with ISDN
POWER LED lights and stays on.
READY LED flashes during self-test (approximately 60 seconds).
READY and ISDN READY LEDs flash during self-tes t (approximately 60 seconds).
READY LED is ON steady after completion of self-test.
READY and ISDN READY LEDs are ON steady after completion of self-test.
The T1 ALARM and FR MGMT. LEDs should not be flashing together. All other LED indications should be ignored at this time.
DATA PO
R
CONFIGURATIO N
O N
123456789101112
O N
12
FUSE
2A/250V
SLOW BLO W
5x20mm
90-250 VAC
.5A
50-60 Hz
CONTROL
OUTPUT
FOR CONTINUED PROTECT ION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE AND RAT ING OF FUSE.
"CAUT ION "
Item Description
Dimensions Table Top (with rubber feet):
Weight As normally packaged including carton and accessories: 8 lbs.
Operating Range
Power Requirements
Regulatory Compliance
6 11
AC Power Connector IEC 320 (mal e)
Page 7
Power Up a FrameSaver NP 110
Power Connections
1. Plug the IEC 320 end of the Power Cord into the connector on the rear of the FrameSaver NP 120.
2. Plug the other end of the Powe r Cord into an AC outlet.
3. The unit will go through the following power-up sequence
FrameSaver NP 110 Power-Up Sequence
If the LED indicat ions ar e not as describ ed above , ref er to S ection 5, “Diag nostics” of the FrameSaver NP 110 User’s Manual - Installation Guide. If operation looks nor- mal, unplug the FrameSaver NP before making input/output connections.
If the unit is to su pply switched power to an other device, plug that dev ice’s power cord into the Switched AC Out connector now.
Proceed to Making Network and Input/Output Connections on page 9 of this guide.
Basic FrameSaver NP 110 FrameSaver NP 1 10 with ISDN
UNIT POWER LED lights and stays on.
UNIT READY LED flashes during self-test (approximately 60 seconds).
UNIT READY and ISDN READY LEDs flash during self-test (approxi mately 60 seconds).
UNIT READY LED is ON steady after completion of self-test.
UNIT READY and ISDN READY LEDs are ON steady after completion of self-test.
NETW ALARM and UNIT FRM MGMT LEDs should not be flashing together. All other LED indications should be ignored at this time.
USER PORT
FUSE
5A/250V
SLOW BLOW
5x20mm
100-240 VAC
5A
50-60 Hz
O N
12
FOR CONTINUED
PROTECTION
AGAINST RISK
OF FIRE,
REPLACE ONLY
WITH S AM E TYP E
AND RATING
OF FUSE.
"CAUT ION"
SWITCHED
AC OUT 250VAC
4.5A MAX
1 2
7
AC Power Connector IEC 320 (male)
Page 8
Power Up a FrameSaver NP 120
Power Connections
1. Plug the IEC 320 end of the Power Cord into the connector on the rear of the FrameSaver NP.
2. Plug the other end of the Power Cord into an AC outlet.
3. The unit will go through the following power-up sequence
FrameSaver NP 120 Power-Up Sequence
If the LED indicat ions ar e not as de scribed above, r efer to Secti on 5, “Diagno stics ” of the FrameSaver NP 120 User’s Manual - Installation Guide. If operation looks nor- mal, unplug the FrameSaver NP before making input/output connections.
If an optional Power Control Unit (PCU) is to be installed with this FrameSaver NP, refer to instructions provided with the PCU and inst all it now.
Proceed to Making Network and Input/Output Connections on the next page of this guide.
Making Network and Input/Output Connections
Be sure you remove AC power from the FrameSaver NP before attaching input and output cables.
All connectors are located on the FrameSaver NP’s rear panel. Make all the necessary connections using the cables listed for that model.
Use caution when connecting to an AUX Port. AUX Port connectors are similar to the Network connectors. Accidental connection of either of the AUX Ports to a Network facility may damage the AUX Port electrical interface.
NOTES:
1. FrameSaver NP 64+, 100, and 120 Data and User Ports support numerous electrical interface types; ITU-V.35, EIA-530, EIA-530-A, ITU-X.21-NS and EIA-232 (FrameSaver NP 64+ only). The Data Port connector is a DB-44 high density female. The adapter cables listed for each model are used to convert from the DB-44 to the appropria te connector typ e for the in terface selected. Th e adapter cable also includes a special wiring pattern at the DB-44 connector, which automatically sets the port to the desired interface type. Refer to the tables on pages 13 - 15 of this guide for cable ordering information if necessary.
2. FrameSaver NP 110 User and Data Ports are configured for ITU-V.35 Interface.
3. FrameSaver NP 120 is designed for use in networks where it is not directly connected to the local PTT’s (non-U.S.) facilities. All the Network connections are made to the customer’s Private Network.
Making ISDN Option Connections
FrameSaver NP units equipped with optional ISDN adapters have additional connec- tors on the rear panel for ISDN Li ne(s) and ISDN Data Port (DTE). The ISD N Data Port supports the same electrical interface types and uses the same connector as the base unit Data Port.
FrameSaver NP 120
POWER LED lights and stays on. READY LED flashes during self-test (approximately 30 seconds). READY LED is ON steady after completion of self-test. The NETWORK ALARM and FR MGMT . LEDs should not be flashin g together.
Refer to User’s Manual - Installation Guide if they are. All other LED indications should be ignored at this time.
USER POR
CONFIGURATIO N
O N
1234 5 6 7 8 910 1112
O N
12
CONTROL
OUTPUT
FUSE
2A/250V
SLOW BLOW
5x20mm
100-240 VAC
.5A
50-60 Hz
FOR CONTINUED PROTECTION AGAINST
RISK OF FIRE, REPLACE ONLY WITH
SAME TYPE AND RATING OF FUSE.
"CAUTIO N"
8
AC Power Connector
IEC 320 (male)
Page 9
Making Network and Input/Output Connections
CAUTION
Be sure you remove AC power from the FrameSaver NP before attaching input and output cables.
All connectors are located on the FrameSaver NP’s rear panel. Make all the necessary connections using the cables listed for that model.
CAUTION
Use caution when connecting to an AUX Port. AUX Port connectors are similar to the Network connectors. Accidental connection of either of the AUX Ports to a Network facility may damage the AUX Port electrical interface.
NOTES:
1. FrameSaver NP 64+, 100, and 120 Data and User Ports support numerous electrical interface types; ITU-V.35, EIA-530, EIA-530-A, ITU-X.21-NS and EIA-232 (FrameSaver NP 64+ only). The Data Port connector is a DB-44 high density female. The adapter cables listed for each model are used to convert from the DB-44 to the appropria te connector typ e for the in terface selected. Th e adapter cable also includes a special wiring pattern at the DB-44 connector, which automatically sets the port to the desired interface type. Refer to the tables on pages 13 - 15 of this guide for cable ordering information if necessary.
2. FrameSaver NP 110 User and Data Ports are configured for ITU-V.35 Interface.
3. FrameSaver NP 120 is designed for use in networks where it is not directly connected to the local PTT’s (non-U.S.) facilities. All the Network connections are made to the customer’s Private Network.
Making ISDN Option Connections
FrameSaver NP units equipped with optional ISDN adapters have additional connec­tors on the rear panel for ISDN Li ne(s) and ISDN Data Port (DTE). The ISD N Data Port supports the same electrical interface types and uses the same connector as the base unit Data Port.
USER POR
9
Page 10
Making DROP/DSX Option Connections (FrameSaver NP 110 only)
FrameSaver NP 110 units equipped with optional DROP/DSX adapters have addition­al connectors on the rear panel for the DROP and DSX Ports. The DROP Port supports the ITU-V.35 interface and the DSX Port is aT1 Network interface.
FrameSaver NP 64+ Specifications
Power Up a FrameSaver NP 110
Power Connections
1. Plug the IEC 320 end of the Power Cord into the connector on the rear of the FrameSaver NP 120.
2. Plug the other end of the Powe r Cord into an AC outlet.
3. The unit will go through the following power-up sequence
If the LED indicat ions ar e not as describ ed above , ref er to S ection 5, “Diag nostics” of the FrameSaver NP 110 User’s Manual - Installation Guide. If operation looks nor- mal, unplug the FrameSaver NP before making input/output connections.
If the unit is to su pply switched power to an other device, plug that dev ice’s power cord into the Switched AC Out connector now.
Proceed to Making Network and Input/Output Connections on page 9 of this guide.
Item Description
Dimensi ons Table Top (with rubbe r feet):
3.0" H x 8.5" W x 11.5" D. Wall Mount (with removable wall mounting bracket):
8.5" H x 11.5" W x 3.0" D. Rack Mount (with removable rack mounting adapter):
3.5" H x 19.0" W ( or 24.0" W ) x 11.5" D.
Weight As normally packaged including carton and accessories: 6 lbs.
Unit alone (without packaging and accessories): 4 lbs.
Operating Range
Temperature: 0 to 50 degrees C. operating. Relative Humidity: 5 to 95% non-condensing. Altitude: 10,000 ft. max. operating, 50,000 ft. max. non-operating. Shock and Vibration: As normally encountered during shipping and handling.
Power Requirements
AC Power Pack (transformer/plug module). Input = 90 - 130 VAC, 0.2 A max., 60 Hz. Output = 22 VAC, 30 VA. Cable: 2-conductor, with 2-pin keyed locking connector, 7 ft. length.
Regulatory Compliance
UL - 1459, Third Edition and CAN/CSA C22.2 No. 225-M90 FCC Part 15, Class A Digital Device Canada’s ICES003, Class A Digital Device FCC Part 68
Basic FrameSaver NP 110 FrameSaver NP 1 10 with ISDN
UNIT READY LED flashes during self-test (approximately 60 seconds).
UNIT READY LED is ON steady after completion of self-test.
NETW ALARM and UNIT FRM MGMT LEDs should not be flashing together. All other LED indications should be ignored at this time.
USER PORT
FUSE
5A/250V
SLOW BLOW
5x20mm
100-240 VAC
5A
50-60 Hz
O N
12
FOR CONTINUED
PROTECTION
AGAINST RISK
OF FIRE,
REPLACE ONLY
WITH S AM E TYP E
AND RATING
OF FUSE.
"CAUT ION"
SWITCHED
AC OUT 250VAC
4.5A MAX
1 2
10
AC Power Connector IEC 320 (male)
Page 11
FrameSaver NP 100 (120) Specifications
DATA PO
R
Item Description
Dimensions Table Top (with rubber feet):
3.5" H x 10.5" W x 12.0"D. Wall Mount (with removable wall mounting bracket):
10.5" H x 12.0" W x 3.5" D. Rack Mount (with removable rack mounting adapter):
5.25" H x 19.0" W ( or 24.0" W ) x 12.0" D.
Weight As normally packaged including carton and accessories: 8 lbs.
Unit alone (without packaging and accessories): 6 lbs.
Operating Range
Temperature: 0 to 50 degrees C. operating. Relative Humidity: 5 to 95% non-condensing. Altitude: 10,000 ft. max. operating, 50,000 ft. max. non-operating. Shock and Vibration: As normally encountered during shipping and handling.
Power Requirements
90 - 250 VAC, 50 - 60 Hz.,15 Watts max. (100 - 240 VAC for FrameSaver NP 120) Fused - 2A/250V Slow Blow, 5x20mm.
CAUTION:
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE FUSE ONLY WITH THE SAME TYPE AND RATING.
ATTENTION:
POUR NE PAS COMPROMETTRE LA PROTECTION CONTRE LE RISQUE D’INCENDIE REMPLACER PAR UN FUSIBLE DE MEMES TYPE ET CARACTERISTIQUE NOMINALES.
Regulatory Compliance
FrameSaver NP 100
: UL - 1459, Third Edition and CAN/CSA C22.2 No. 225-M90; FCC Part 15, Class A Digital Device; FCC part 68;Canada’s ICES003, Class A Digital Device
FrameSaver NP 120
: UL-1950; C AN/CSA C22. 2 No. 2 25- M90; FCC Part 15, Class B Digital Device; Canada’s ICES003, Class A Digital Device; EN 60950; EN 50082-1:1992; EN 55022:1995; EMI: EN 55022 Class B
Page 12
FrameSaver NP 110 Specifications
2. Plug the Power Pac at the other end of the power cord into an AC outlet.
3. The unit will go through the following power-up sequence:
If the LED indicat ions ar e not as describ ed above , ref er to S ection 5, “Diag nostics” of the FrameSaver NP 64+ Users Manual - Installation Gu ide.
If operation l ooks normal, u nplug the FrameSaver NP befo re making inpu t/output con - nections.
If an optional Power Control Unit (PCU) is to be installed with this FrameSaver NP, refer to the instructions provided with the PCU and install it now.
Proceed to Making Network and Input/Output Connections on page 9 of this guide.
Item Description
Dimensions Table Top (with rubber feet):
3.5" H x 10.5" W x 12.0"D. Wall Mount (with removable wall mounting bracket):
10.5" H x 12.0" W x 3.5" D. Rack Mount (with removable rack mounting adapter):
5.25" H x 19.0" W ( or 24.0" W ) x 12.0" D.
Weight As normally packaged including carton and accessories: 8 lbs.
Unit alone (without packaging and accessories): 6 lbs.
Operating Range
Temperature: 0 to 50 degrees C. operating. Relative Humidity: 5 to 95% non-condensing. Altitude: 10,000 ft. max. operating, 50,000 ft. max. non-operating. Shock and Vibration: As normally encountered during shipping and handling.
Power Requirements
AC Input 100 - 240 VAC, 50 - 60 Hz., 5.0A max.
0.5A max. for the unit’s internal power requirements.
4.5 A max. for device (if any) connected to the Switched AC Output. Fused - 5A/250V Slow Blow, 5x20mm. Switched AC Output: max, 250 VAC, 4.5 A.
CAUTION:
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE FUSE ONLY WITH THE SAME TYPE AND RATING.
ATTENTION:
POUR NE PAS COMPROMETTRE LA PROTECTION CONTRE LE RISQUE D’INCENDIE REMPLACER PAR UN FUSIBLE DE MEMES TYPE ET CARACTERISTIQUE NOMINALES.
Regulatory Compliance
UL - 1950, Third Edition and CAN/CSA C22.2 No. 950-95, Third Edition, FCC Part 15, Class A Digital Device, Canada’s ICES003, Class A Digital Device, FCC Part 68
Basic FrameSaver NP 64+ FrameSaver NP 64+ with ISDN
READY LED may flash several times, then remain OFF during self-test (approxi mately 45 seconds).
READY LED is ON steady after completion of self-test.
The DDS ALARM and FR MGMT. LEDs should not be flashing together. All other LED indications should be ignored at this time.
Page 13
Contact your service representative, distr ibutor or s ales repres entative to ord er cables .
FrameSaver NP 64+ Cable List
Description Part No.
DDS network cable, RJ-48, twisted pair 135-982-0006 Dial Line (POTS) cable, RJ-11 connector 135-007-7200 ISDN BRI network cable, RJ-49 connector 135-981-0006 EIA-232 Data Port (DTE) cable 135-000-0400 EIA-530 Data Port (DTE) cable 135-002-0400 EIA-530A Data Port (DTE) cable 135-003-0400 ITU-X.21-NS Data Port (DTE) cable 135-005-0400 ITU-V.35 Data Port (DTE) cable 135-001-0400 ITU-V.35 Data Port (DTE) cable to Cisco router serial port,
HD-60 connector
135-006-0400
Console cable (to AUX2), DB-9 connector 135-000-0464 Console cable (to AUX2), D B -25 connector 135-007-0400 AUX Port to router console port cable, DB-25 connector 135-008-0400 AUX Port to Cisco router console port, RJ-45 type connector 135-990-0006
134
Page 14
Contact your servi ce repr esen ta tiv e, di s tri but or or s al es repr esen tati ve to ord e r cables .
Before You Begin
Ensure you have the following:
A dedicated, grounded, circuit breaker p rotected power outlet within six feet o f the FrameSaver NP unit.
A suitable location for the unit that is clean, well-lit, ventilate d and free fro m environmental extremes.
One to two feet of clearance for cable connections to the unit.
Package Checklist
Verify that the packaging contains the following:
FrameSaver NP unit
Unit power cord or AC Power Pack with cord
If ordered, optional wall-mount or rack-mount bracket assembly.
In addition, you will need Input/Output cables if not already supplied. These cables are listed for each FrameSaver NP Model on pages 13 - 15 of this guide.
Mounting the FrameSaver NP
FrameSaver NP units come equipped with rubber feet for table or shelf-top placemen t. Optional adapter brackets are available for wall mounting (Model 64+ includes wall- mount key-holes in its base) and standard 19" or 24" rack mounting. To attach and mount adapter brackets, follow the instructions supplied with the mounting adapters.
Allow sufficient space for cooling and access to the front panel indicators for trouble- shooting in all installations.
FrameSaver NP 100 (120) Cable List
Description Part No.
T1 network cable, RJ-48, twisted pair (NP 100 only) 135-982-0006 Dial Line (POTS) cable, RJ-11 connector (NP 100 only
) 135-007-7200 ISDN BRI network cable, RJ-49 connector (NP 100 only) 135-981-0006 EIA-530 Data Port (DTE) cable (NP 100 only
) 135-002-0400
EIA-530A Data Port (DTE) cable (NP 100 only
) 135-003-0400 ITU-X.21-NS Data Port (DTE) cable (NP 100 only) 135-005-0400 ITU-V.35 Data Port (DTE) cable (NP 100 only
) 135-001-0400
ITU-V.35 Data Port (DTE) cable to Cisco router serial port,
HD-60 connector (NP 100 only
)
135-006-0400
Console cable (to AUX2), DB-9 connector 135-000-0464 Console cable (to AUX2), DB-25 connector 135-007-0400 AUX Port to router console port cable, DB-25 connector 135-008-0400 AUX Port to Cisco router console port, RJ-45 type connector 135-990-0006 ITU-V.35 Compliant network cable (NP 120 only
) 135-001-0480
ITU-X.21-NS network cable (NP 120 only
) 135-005-0480 ITU-V.35 Compliant User Port cable (NP 120 only) 135-002-0480 EIA-530 User Port cable (NP 120 only
) 135-003-0480
EIA-530A User Port cable (NP 120 only
) 135-004-0480
14 3
Page 15
Contact your service representative, distr ibutor or s ales repres entative to ord er cables .
FrameSaver NP 110 Cable List
Description Part No.
T1 or DSX network cable, RJ-48, twisted pair 135-982-0006 Dial Line (POTS) cable, RJ-11 connector 135-007-7200 ISDN BRI network cable, RJ-49 connector 135-981-0006 Console cable (to AUX2), DB-9 connector 135-000-0464 Console cable (to AUX2), D B -25 connector 135-007-0400 AUX Port to router console port cable, DB-25 connector 135-008-0400 AUX Port to Cisco router console port, RJ-45 type connector 135-990-0006
15
Page 16
Trademarks
FrameSaver is a registered trademark of Paradyne Corporation. All other products, systems, or services mentioned in this documen t are tradem arks , service mar ks , regis ­tered trademarks or registered service marks of their respective owners.
Copyright Notice
© Copyright 1999-2000 Paradyne Corporation. All rights reserved.
Sales, Service and Warranty Information
Telephone:
201-703-4800
Internet:
http://www.paradyne.com
FAX:
201-703-4889
Mail:
Paradyne Corporation
16-00 Pollitt Drive Fair Lawn NJ 07410
FrameSaver
Installation & Quick Reference Guide
FrameSaver NP Models 64+, 100, 110 and 120
Document Number 980-000-0272B August 2000
This Quick Reference Guide provides an over view on how to inst all a FrameSaver NP Model 64+, 100, 110 or 120 unit. This includes making the physical connections be- tween the unit, netw ork, DTE device(s), and telephone line. It also tells you ho w to find more detailed information about your FrameSaver NP.
Product Documentation on the World Wide Web
We provide complete product documentation online. This lets you search the docu- mentation for specific topics and print only what you need, reducing the waste of sur- plus printing. It also helps us provide timely product update information and maintain competitive prices for our products.
Complete documentation for these products is available at Select Library
FrameSaver NP (NetPath) Frame Relay Digital Access Units
Select the appropriate document from the documentation list:
FrameSaver NP 64+ User’s Manual - Installat ion Guide, Publicatio n # 980-001- 0221 FrameSaver NP 100 U s er’s M an ual - Installatio n G u id e , P ub licati o n # 980-001-0210 FrameSaver NP 110 U s er’s M an ual - Installatio n G u id e, P ub l ication # 980-001- 024 0 FrameSaver NP 120 U s er’s M an ual - Installatio n G u id e, P ub l ication # 980-001- 023 0
Loading...