Paradyne 3800Plus, COMSPHERE 3811Plus, COMSPHERE 3810Plus Quick Reference

Page 1
COMSPHERE 3800Plus
SERIES MODEMS
MODELS 3810Plus and 3811Plus
QUICK REFERENCE
Document No. 3980-A2-GL10-10
Page 2
Copyright E 2002 Paradyne Corporation. All rights reserved. Printed in U.S.A.
Notice
This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773.
Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes.
Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual.
Warranty, Sales, and Service Information
Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:
H Via the Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. H Via Telephone: Call our automated system to receive current information via
fax or to speak with a company representative.
— Within the U.S.A., call 1-800-870-2221 — Outside the U.S.A., call 1-727-530-2340
Trademarks
COMSPHERE is a registered trademark of Paradyne Corporation. All other products and services mentioned herein are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners.
Document Feedback
We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.
Page 3
1
COMSPHERE 3800Plus Series Modems Models 3810Plus and 3811Plus
Quick Reference
Document Number 3980-A2-GL10-10 February 2002
Product Documentation on the World Wide Web
Complete documentation for this product is available at www.paradyne.com. Select Library Technical Manuals Business Class Analog Modems.
Select the following document:
3980-A2-GB30
COMSPHERE 3800Plus Series Modems User’s Guide
To request a paper copy of a Paradyne document:
H Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396) H Outside the U.S.A., call 1-727-530-8623
Before installing your modem, read the Important Safety Instructions on page 23.
Package Checklist
After opening the modem’s package, check for damage and verify that the following items are present:
H 3810Plus modem H Power supply H One 6-position modular cord (in selected models) H One 8-position modular cord (in selected models)
Page 4
2
Model 3810Plus Installation
DTE Connection
Use the following procedure to connect the RS-232D cable from the modem to the DTE:
1. Make sure the modems rear panel power switch is Off.
2. Connect the DB-25-P (male) connector on the cable to the DB-25-S (female)
connector labeled DTE 1 on the modems rear panel. Use a small screwdriver to fasten the cable to the modem.
3. Connect the DB-25-P connector on the cable to the DB-25-S connector on the DTE. Use a small screwdriver to fasten the cable to the DTE.
98-14677-03
DATA
TERMINAL
EQUIPMENT
DB-25-P
CONNECTOR
SUB-MINIATURE 4-POSITION PLUG FOR
NETWORK MANAGEMENT SYSTEM
OPERATION
POWER
SUPPLY
DIAL NETWORK
6-POSITION PLUG
LEASED-LINE
NETWORK
8-POSITION
PLUG
OFF
DIAL
LEASED
DTE 1
NMS
PWR ON
HUBBING
DEVICE
3810Plus Rear Panel
Page 5
3
Dial-Line Connection
Use the following procedure to connect the 3810Plus modem to the dial network interface:
1. Insert the 6-position, 4-conductor modular plug into the jack labeled DIAL/LEASED.
2. Insert the other end of the modular cord into the dial network interface.
3810Plus 4-Wire/2-Wire Leased-Line Network Connection
Use the following procedure to connect a 3810Plus modem to the leased-line network interface:
1. Insert the 8-position, 8-conductor modular plug into the jack labeled LEASED (3810Plus).
2. Insert the other end of the modular cord into the leased-line network interface.
3. If you intend to use dial backup, follow steps listed in Dial-Line Connection section.
AC Power Supply Connection
!
WARNING:
Power supplies from other modems may fit into the POWER connector, but connecting the wrong power supply can cause damage to the modem or the power supply.
Use the following procedure to connect the modem to an ac power outlet:
1. Make sure the modems power switch is in the Off position.
2. Insert the power transformers cylindrical connector into the modems rear panel
power receptacle.
3. If the modem is provided with a tabletop power supply, connect the power cord to the power supply module.
4. Connect the power supply to a grounded ac power outlet.
Page 6
4
Network Management System Connection
For the 3810Plus modem, use the following procedure to connect the modem to the network management system interface:
1. Insert the subminiature 4-position, 4-conductor modular plug of the 3600 Hubbing Device into the jack labeled NMS.
2. Connect the 3600 Hubbing Device to the network management system.
Refer to the 3600 Hubbing Device, Feature Number 3600-F3-300, Installation Instructions for more information. Installation for the 3810Plus modem is the same as for the 3610 DSU.
3000HUBBING
DEVICE
M
O
DEL
#3000-F3-300
8-Pin
Modular
Jacks
6 Inches
Overall
4-Pin
Modular
Plug
496-13775-03
8
1
Pin
Numbers
8
1
CC IN/DC OUT
CC OUT/DC IN
CC IN/DC OUT
Hubbing Device
CC OUT/DC IN
3600 Hubbing Device
Page 7
5
Model 3811Plus Installation
The COMSPHERE 3000 Series Carrier has 17 slots which can hold up to 16 modems and one SDU. The SDU is required when the modems in the carrier are controlled by an NMS, or when multiple carriers in a cabinet configuration are to be controlled by a single SDCP. The SDCP of the COMSPHERE 3000 Series Carrier is the user interface to the 3811Plus modem. A single SDCP can control modems in up to eight carriers.
To install a 381 1 Plus modem into the carrier, perform the following steps.
1. At the rear of the carrier, install the rear connector plate. Make sure the plate uses the same slot position as that intended for the modem.
496-14906
V.35
(3600/3500)
RS366A/V.25
(3800)
EIA232/V.24
25-Pin
DTE Connectors
P21
Loosely fasten the plate. This allows for slight adjustments later when installing the modem.
CAUTION:
Always use a ground strap when handling a modem. Always store a 3811Plus modem in an antistatic bag when it is removed from the carrier.
Page 8
6
495-14797
2. At the front of the carrier, hold the modem vertically, with the latch on its faceplate in the open position, and insert it into the top and bottom card guides of one of the slots numbered 1–16.
Slide the modem into the slot, aligning the modem with the rear connector plate, until the backplane connector and DTE connector seat firmly into the back of the carrier. To lock the modem into the carrier, press the faceplate latch until a click is heard.
3. Rotate the circuit pack lock(s) into the closed position, and tighten the screw.
Page 9
7
Circuit
Card
Guides
Circuit
Pack Lock
Latch
Open
(Unlocked)
Closed
(Locked)
495-14813
4. If the carrier is connected to power, the Power LED on the faceplate of the 3811Plus lights up. After several seconds the modem completes its power-up self-test in which all faceplate LEDs light up.
If the modem fails, or an alarm condition exists, the Alrm LED on the faceplate lights up or flashes. It may be possible to run a diagnostic self-test from the SDCP. See Test Branch in the COMSPHERE 3800Plus Modems Users Guide.
Return to the rear of the carrier and tighten the rear connector plate.
5. Connect an RS-232D DTE cable to the top connector of the rear connector plate. (The bottom connector is unused.)
6. Connect the other end of the cable to your DTE.
Page 10
8
Diagnostic Control Panel
The Diagnostic Control Panel (DCP) is the user interface to the modem. It provides a 2-line, 32-character liquid crystal display (LCD), a keypad, speaker grill, and status indicators.
A Shared DCP (SDCP) is used to manage carrier-mounted 3811Plus modems. The Select key is used to connect the SDCP to a modem or other device in a specific carrier and slot location. Press the Select key, then enter the modem carrier (1–8) and slot (1–16) numbers. Once the modem is selected, operation of the SDCP is the same as for the standalone DCP.
TXD RXD RTS CTS DSR DTR LSD
103 104 105 106 107 108 109
Pwr Alrm Test Dial RI Busy
Serv
SQ
Status
Front Panel
3811
Plus
142
125
Spkr
Moves up one level from the current display. Moves cursor or display to the left or right. Returns display to Top-Level menu. Selects item displayed directly above the key.
F1, F2, F3
and
Direction and Function keys provide operator control.
Hidden Choice Indicators.
Indicates more LCD selections are available to the left or right of what is currently displayed on the LCD.
Indicates more configuration options are available below what is currently displayed. Also indicates selected configuration option.
Indicates last configuration option available for that group.
Nxt End
Select
SDU12345678910111213141516
COMSPHERE 3000
SELECT
KEY
STATUS
INDICATORS
CARRIER SLOTS 1–16
F1 F2 F3
OK Alarm BckUp Test EC
NETWORK
DEVICE
ALARM
DIAL
BACKUP
TEST
MODE
ERROR
CORRECTION
OK Alarm BckUp Test EC
KEYPAD
LCD
496-14487a
Page 11
9
Checking the SDCP
If an SDCP is installed, verify that the SDCP can be used to control the 3811Plus modem. Perform the following steps.
Select
SDU1 2 3 4 5 6 7 8 9 10111213141516
COMSPHERE 3000
Select
Key
Status
Indicators
Carrier Slots 1–16
F1 F2 F3
OK Alarm BckUp Test EC
Keypad
LCD
Display
496-12348a-03
1. Press the
Select
key on the SDCP. The cursor appears in the 2-digit slot
selection entry.
2. Press the
key to position the cursor on the 2-digit carrier selection entry.
3. Press the F1 () or F2 () key until the carrier number you want appears on the LCD.
The carrier number selection has a range of 1 to 8. With an SDU installed, a single SDCP can control up to eight carriers.
4. Press the
key to position the cursor on the slot selection entry.
5. Press the F1 () or F2 () key until the slot number (116) you want appears on the LCD. (Ignore the AB designator that appears on the LCD since it is not applicable to the 3811Plus modem.)
The Front Panel LED on the modems faceplate lights up.
6. Press the
Select
key to place the SDCP in direct communication with the
selected modem. The LCD displays the Top-Level menu for the selected modem.
Administrative Password
The Administrative Password is an 8-digit decimal number password that allows only authorized users to access Security branch functions. The Administration Password must be entered every time the Security branch is accessed. The factory default Administration Passsword is 00000000.
The Reset_Security function of the Security branch resets the Administrative Password to the value above the bar code on the last page of this reference.
Page 12
10
3800Plus Modems Menu Tree
Call_Setup Status Test
“Status”
Dial
Disconnect
Answer
Dial_Standby
or
Return_to_Dial
Change_Directory
Directory Locations 1 – 10
Abort Self
Loc_Analog_Loop
Rem_Digital_Loop
Loc_Digital_Loop
Pattern
DTE_Interface
Async/Sync Mode Async DTE Rate Sync DTE Rate #Data Bits Parity Bit #Stop Bits DTR Action DSR Control RTS Action CTS Control RTS/CTS Delay LSD Control TX Clock Source CT111_Rate Cntl DTE_Rate = VF
DTE_Dialer
DTE Dialer Type AT Escape Char Escape GuardTim BreakForceEscap CommandCharEcho CarriageRtn Char Backspace Char Linefeed Char Result Codes ExtendResltCode ResultCode Form V25bis Coding V25bis IdleFill V.25b NewLineChr AT Cmnd Mode DTR Cont Repeat
Line_Dialer
AutoAnswerRing# Dialer Type DialTone Detect Blind Dial Paus BusyTone Detect "," Pause Time NoAnswer Timout Fast Disconnect Long Space Disc No Carrier Disc No Data Disc NoDataDiscTrig Auto Make Busy MakeBusyViaDTR DTR Auto Redial MI/MIC Dialing
Dial_Line
Modulation Dial Line Rate Automode Autorate Dial TX Level V22b Guard Tone Train Time Asymmetric Rate Proactive Retrain Fall Fwd Delay
98-15990a-01
Displays current status of modem along with data rate and error control mode.
Does not appear in Remote Mode. (Rem_Digital_Loop, Loc_Digital_Loop, and Pattern appear if the secondary channel Remote Mode is used.)
Some choices within this group may not appear depending upon how previous configuration options have been selected.
to next page
to next page
VF
Identity
SigQual RcvLev Sig/Noise NearEcho FarEcho FarEchDel EchoFreqOff
Ser# Mod # FRev HPt# FPt#
DTE
LSD DTR DSR Tst TXD RXD RTS CTS
SDC
Record
Display
Clear
No Signal
Options
TX
RX
Page 13
11
Configure
Ld EditArea frm:
Edit Save
Choose Function
Active (Saved) Customer1 Customer2
V42/MNP/Buffer
Err Contrl Mode Sync Comp Mode SDC Negotiation SDC Idle Fill SDC BitEncoding SyncDTE CRC SDC Delay Min Sync Flow Cntrl V42bis Compress MNP5 Compress EC Negotiat Bfr EC Fallbck Char Flw Cntl of DTE Flw Cntl of Mdm XON/XOFF Psthru Mdm/Mdm FlowCtl Break Buffr Ctl Send Break Cntl [SDC Options] Tx Buff Disc Delay Rx Buff Disc Delay Max Frame Size Cellular Enhance BfrSizeInBfrMode
Test
DTE RL (CT140) DTE LL (CT141) Test Timeout Rcv Remote Loop V54 Address V54 Device Type
Misc
StrapsWhenDisc Speaker Control Speaker Volume Access frm Remt RemAccssPasswrd Dir#1_Callback NetMngmtAddress NMS_Call_Msgs NMS DTR Alarm NetworkPosition CellulrRJ11Adpt
Security
EntryWait_Time VF_Prompt_Type #DTE_PW_Tries DTE_PW_TermChar DTE_PW_BkSpChar Get_User_ID NMS_Reporting Answer_Secur Originate_Secur
98-15990b
Does not appear if configured for Synchronous mode
Only appears if Sync_Leased factory template is selected.
Some choices within this group may not appear depending upon how previous configuration options have been selected.
Some choices within this group appear only if optional features are installed.
from previous page
from previous page
to next page
Leased_Line
Leased Mode Modulation LeasedLine Rate Autorate Leased TX Level Bad Ln Auto Orig Rate Auto Orig Auto Redial AutoDialStandby CarrierOn Level V .29 TrainOnData Asymmetric Rate Fall Fwd Delay
Activ (Operating)
Active (Saved)
Customer1
Customer2 Factory
Async_Dial
Sync_Dial
Sync_Leased
UNIX_Dial
Choose Mode
Answer Originate
Cellular (PSTN)
Cellular
(Mobile)
Page 14
12
Control Remote
Speaker
Reset
Make_Busy
or
RemoveMakeBusy
Service_Line
or
DiscServLine
Download Code
Secondary Prim (data blckd)
(ExitRem appears
instead of Remote when
using Remote Mode)
Does not appear in Remote Mode.
Security
Set_Access_Ctrl
(Admin Password?)
Reset_Security
EditPassWdTable
Set_Answer_Sec
Set_Orig_Secur
Set_Admin_PsWd
98-15990c-01
from previous page
Page 15
13
Configuration Option Procedures — DCP Commands
1. Move to the Configure branch and select a configuration area to load from: Active (Operating), Active (Saved), Customer 1, Customer 2, or Factory (Async Dial, Sync Dial, Sync Leased, or UNIX Dial). If Enhanced Throughput Cellular (ETC) is installed, Factory areas Cellular (Mobile) and Cellular (PSTN) are also available.
Select Configure from the Top-Level menu.
F1
Idle : 28.8 Test Configure
F2
F3
Scroll to the area you wish to load.
F1
Ld EditArea frm < Factory
F2
F3
2. Select Edit to choose the set of configuration options to be edited: DTE Interface, DTE Dialer, Line Dialer, Dial Line, Leased Line, V.42/MNP/Buffer, Tests, Misc, or Security.
F1
Edit StrapGroup < Test Misc
F2
F3
3. When the new configuration is completed, Save the edited configuration options to the desired configuration area: Active (Saved), Customer 1, Customer 2.
F1
Sav EditArea to > Active (Saved)
F2
F3
Page 16
14
Configuration Option Procedures AT Commands
Loading Factory Configurations
Use the AT&Fy&Wn command to load a factory configuration to either the Active (Saved), Customer 1, or Customer 2 configuration area.
Type: AT&Fy&Wn where: y is one of the following factory configurations:
0 = Async Dial 1 = Sync Dial 2 = Sync Leased (Answer) 3 = UNIX Dial 4 = Sync Leased (Originate) 5 = Cellular (Mobile) (if ETC installed) 6 = Cellular (PSTN) (if ETC installed)
where: n is one of the following configuration areas:
0 = Active (Saved) 1 = Customer 1 2 = Customer 2
Loading Configuration Areas to Active (Operating)
Use the ATZn command to load stored configurations from Active (Saved), Customer 1, or Customer 2 configuration areas to Active (Operating).
Type: ATZn where: n is one of the following:
0 = Active (Saved) 1 = Customer 1 2 = Customer 2 3 = Active (Saved) + Reset
Page 17
15
AT COMMANDS
Bold text indicates Async Dial factory defaults.
A T Attention Command Prefix/Autobaud
Rate. Indicates a command string has started and determines the DTEs data rate and parity.
A/ Repeat Last Command. Reexecutes last
command string. (Not to be preceded with AT or followed by pressing the Return key.)
A Answer Mode. Goes off-hook and
attempts to establish a connection without waiting for a ring.
B0 ITU-T V.21 or V.22 (300 or 1200 bps) B1 Bell 103 or 212A (300 or 1200 bps)
Dn Dial. Dials the telephone number n with
optional modifiers: T Tone Dial (DTMF)
P Pulse Dial , Pause W Wait for Dial Tone R Reverse Dial @ Quiet Answer ! Hook Flash ; Return to Command Mode
DS=n Dial Stored Number. Dials the number
stored in location n (1–10).
En Command Character Echo
E0 Disables echo to the DTE.
E1 Enables echo to the DTE.
H0 Modem goes on-hook. H1 Modem goes off-hook.
I0 Displays product code–144. I1 Displays 3-digit firmware revision
number.
I2 Performs an EPROM check. I3 Displays modems serial number. I4 Displays modems model number. I5 Displays part number of circuit card. I6 Displays firmware release number. I9 (same as I1) I10=n Changes value of product code (0=144,
1=240, 2=480, 3=960, 4=120).
I1 1 Firmware checksum. I19 Displays entire firmware revision number.
Ln Speaker Volume
L0,L1 Selects low volume.
L2 Selects medium volume.
L3 Selects high volume.
AT COMMANDS (continued)
Mn Speaker ON/Off Control
M0 Speaker always Off.
M1 Speaker ON until carrier signal
becomes active.
M2 Speaker always ON. O Returns modem to Data mode from
online Command mode.
P Enables Pulse Dial mode.
Qn Result Codes
Q0 Enables result codes. Refer to Result
Codes section.
Q1 Disables result codes. Q2 Enables originate modem to send result
codes to the DTE. Required for most UNIX applications.
Sn? Displays value of S-Register (where n is
the register number).
Sn=r Change S-Register. Changes the
contents of the S-Register (where n is the register number and r is the assigned value).
T Enables Tone Dial mode.
Vn Result Code Format
V0 Displays as digits (Numbers 1).
V1 Displays as text.
V2 Displays as digits (Numbers 2).
Xn Extended Result Codes; Dial Tone
Detect; Busy Tone Detect
X0 Disables extended result codes 5–16,
dial tone detect, and busy tone.
X1 Enables extended result codes 5–16,
disables dial tone detect and busy tone detect. Refer to Result Codes section.
X2 Enables extended result codes 5–16, dial
tone detect, and disables busy tone detect.
X3 Enables extended result codes 5–16,
disables dial tone detect and enables busy tone detect. Refer to Result Codes section.
X4 Enables extended result codes 5–16,
dial tone detect, and busy tone detect. Refer to Result Codes section.
X5 Adds EC suffix to extended result codes
(20–27) if error control is used, enables dial tone detect and busy tone detect.
X6 Adds either V.42 or MNP suffix to
extended result codes (20–27) if data compression is used, enables dial tone detect, and busy tone detect.
X7 DTE rate appears in CONNECT
message instead of line rate, enables dial tone detect and busy tone detect. Refer to Result Codes section.
Page 18
16
AT COMMANDS (continued)
Yn Long Space Disconnect
Y0 Disable.
Y1 Enable.
Zn Reset and Load Active
Z0 Loads contents of Active (Saved) into
Active (Operating).
Z1 Loads contents of Customer 1 into Active
(Operating).
Z2 Loads contents of Customer 2 into Active
(Operating).
Z3 Loads contents of Active (Saved) into
Active (Operating) and performs a reset.
Z9 Performs a full modem reset.
+FCLASS=n Fax class
+FCLASS=0 Data +FCLASS=1 Fax Class 1 (EIA 578) +FCLASS=2 Fax Class 2 (EIA/TIA SP-2388)
&Cn LSD Control
&C0 Forced On. Forces LSD ON at all times.
&C1 Standard RS232. LSD is ON when the
remote modems carrier signal is detected. LSD is Off when carrier signal is not detected.
&C2 Wink When Disc. LSD, normally forced
ON, turns Off for approximately 1 to 2 seconds upon disconnect.
&C3 Follows DTR. State of LSD follows state
of DTR.
&C4 Simulated Control Carrier. State of LSD
follows state of remote modems RTS.
&C5 =DTR/DiscOff. State of LSD follows
state of DTR except upon a disconnect where DTR remains ON and LSD turns Off. DTR must then toggle Off and ON to turn LSD ON. Required for AT&T DATAKIT
dial-out applications.
&C6 Bridge Retrain. LSD behaves as in
Standard RS232, except that it is turned Off when retrain lasts longer than 10 seconds, and ON when no retrain is detected for 10 seconds.
&Dn DTR Action
&D0 Ignore. Modem ignores the DTR (Data
T erminal Ready) signal and treats it as always ON.
&D1 Off=Command Mode. Modem enters
online Command mode when DTR is lowered.
&D2 Standard RS232. DTR signal is
controlled by the DTE.
&D3 Off=Reload Straps. Modem loads Active
(Operating) area with Active (Saved) area when DTR is lowered.
&D4 Controls On-Hook. Modem does not
disconnect until DTR lowered by DTE.
AT COMMANDS (continued)
&Fn Loads Factory Configuration
&F0 Loads Async Dial factory configuration
options into Active (Operating) configuration area.
&F1 Loads Sync Dial factory configuration
options into Active (Operating) configuration area.
&F2 Loads Sync Leased (Answer Mode)
factory configuration options into Active (Operating) configuration area.
&F3 Loads UNIX Dial factory configuration
options into Active (Operating) configuration area.
&F4 Loads Sync Leased (Originate Mode)
factory configuration options into Active
(Operating) configuration area. &F5 Cellular (Mobile) (if ETC installed). &F6 Cellular (PSTN) (if ETC installed).
&Gn V.22bis Guard Tone
&G0 Disables guard tone.
&G1 Sets guard tone to 550 Hz. &G2 Sets guard tone to 1800 Hz.
&
In Dial Transmit Level
&
I10 –10 dBm.
&
I11 –11 dBm.
&
I32 –32 dBm.
&
I99 ETC 1.0 (if ETC installed).
&
I100 ETC 1.1 (if ETC installed).
&Jn Dial Transmit Level T ype
&J0 Modem sets dial transmit level to
Permissive mode at –9 dBm.
&Ln Leased-Line Mode
&L0 Disables leased-line operation. &L1 2-wire originate leased-line operation. &L2 4-wire originate leased-line operation. &L3 2-wire answer leased-line operation. &L4 4-wire answer leased-line operation.
&Mn,&Qn Async/Sync Mode and DTE Dialer Type
&M0,&Q0 Modem operates in Async mode and
uses AT command protocol.
&M1,&Q1 Modem operates in Sync mode and uses
A T command protocol. &M2,&Q2 Modem operates in Sync mode and dials
the number stored in directory location 1
when DTR signal turns Off and then ON. &M3,&Q3 Modem operates in Sync mode and uses
A T command protocol. &Q4 Modem operates in Async mode and
uses AT Command protocol; Hayes
AutoSync is enabled. &M6,&Q6 Modem operates in Sync mode and dials
the number stored in directory location 1
when DTR signal turns Off and then ON
and leased line is down. &M231, &Q231 Modem operates in Async mode;
the DTE Dialer Type is disabled.
Page 19
17
AT COMMANDS (continued)
&M232, &Q232 Modem operates in Async mode;
V .25bis Async dialing is enabled.
&M233, &Q233 Modem operates in Sync mode;
V .25 Bisync dialing is enabled.
&M234, &Q234 Modem operates in Sync mode;
V .25bis HDLC dialing is enabled.
&M235, &Q235 Modem operates in Async mode;
A T&T Exclusive dialing is enabled.
&M236, &Q236 Modem operates in Sync mode; the
DTE Dialer Type is disabled.
&Rn RTS Action
&R0 Standard RS232. RTS action is
controlled by DTE.
&R1 Ignores RTS. Modem ignores RTS
signal and treats it as always ON.
&R2 Simulated Control Carrier. State of RTS
follows state of LSD.
&R3 Control Carrier. DTEs RTS signal
controls modems carrier signal.
&Sn DSR Control
&S0 Forced On. Forces DSR signal ON.
&S1 Standard RS232. Modem controls DSR
signal.
&S2 Wink When Disc. DSR signal turns Off
for approximately 1 to 2 seconds upon disconnecting.
&S3 Follows DTR. Modem sends DSR to DTE
when it receives DTR from DTE.
&S4 On Early. DSR is Off when modem is in
idle state. DSR goes ON when modem enters Data mode.
&S5 Delay to Data. DSR does not turn ON
until the modem enters Data mode.
&S6 Dial Backup toggle.
&Tn Tests
&T0 Stops any test in progress. &T1 Starts a Local Analog Loopback test
(V .54, L3).
&T2 Transmits and receives a 511 BERT
pattern. &T3 Starts a Local Digital Loopback test. &T4 Accepts request from remote modem for
a Remote Digital Loopback test. &T5 Denies request from remote modem for a
Remote Digital Loopback test. &T6 Starts a Remote Digital Loopback test
(V .54, type L2). &T7 Starts a Remote Digital Loopback test
with a Pattern (V .54, type L2). &T8 Starts a Local Analog Loopback test
with a Pattern (V .54, type L3). &T9 Starts a self-test.
AT COMMANDS (continued)
&Vn View Configuration Options
&V0 Displays Active (Operating) configuration
options.
&V1 Displays Active (Saved) configuration
options.
&V2 Displays Customer 1 configuration
options.
&V3 Displays Customer 2 configuration
options.
&V4 Displays telephone numbers stored in
directory locations 1–10.
&Wn Write (Save to Memory)
&W0 Saves current configuration options in
Active (Operating) to Active (Saved).
&W1 Saves current configuration options in
Active (Operating) to Customer 1.
&W2 Saves current configuration options in
Active (Operating) to Customer 2.
&Xn Transmit Clock Source
&X0 Modem provides internal clock source
for synchronous data (Pin 15).
&X1 Modem uses external source (Pin 24) for
clock for synchronous data.
&X2 Modem uses received signal as clock
source for synchronous data.
&Zn=x Modem stores telephone number x (and
any dial modifiers) in directory location n (1–10). For example, the command A T&Z1=555-1234 stores the number 5551234 in directory location 1. To clear a telephone number from a memory location, issue &Zn=x without entering a telephone number.
\An Maximum Frame Size \A0 64 \A1 128 \A2 192 \A3 256 \A4 32 \A5 16
\Cn Error Control Negotiate Buffer
\C0 Data is not buffered during
handshaking sequence.
\C1 Data is buffered up to 4 seconds during
handshaking sequence.
\C2 Data is not buffered during
handshaking sequence; however, the modem switches to Buffer mode when it receives an error control fallback character.
Page 20
18
AT COMMANDS (continued)
\Dn CTS Control
\D0 Forced On. CTS is forced ON.
\D1 Standard RS232 operation. \D2 Wink When Disc. CTS turns Off for
approximately 1 to 2 seconds upon
disconnecting. \D3 Follows DTR. The state of CTS follows
the state of DTR.
\Gn Modem-to-Modem Flow Control
\G0 Disables modem-to-modem flow
control.
\G1 Enables modem-to-modem flow control.
\Kn Break Buffer Control, Send Break
Control, Break Forces Escape
\K0 Discards data, sends break before data,
and enables break forces escape. \K1 Discards data, sends break before data,
and disables break forces escape. \K2 Keeps data, sends break before data,
and enables break forces escape. \K3 Keeps data, sends break before data,
and disables break forces escape. \K4 Keeps data, sends data before break,
and enables break forces escape.
\K5 Keeps data, sends data before break,
and disables break forces escape. \K6 Discards break, disables break forces
escape.
\Nn Error Control Mode
\N0 Buffer Mode. Modem does not use error
control; DTE rate can differ from VF rate. \N1 Direct Mode. Modem does not use error
control; DTE rate and VF rate must be
the same. \N2 MNP or Disc. Modem disconnects if it
does not connect in MNP mode. \N3 MNP or Buffer. Modem connects in
Buffer mode if it does not connect in MNP
mode. \N4 V.42/MNP or Disc. Modem disconnects if
it does not connect in V .42 or MNP mode.
\N5 V.42/MNP or Buffer . Modem connects
in Buffer mode if it does not connect
in V .42 or MNP mode. \N6 LAPM or disconnect. \N7 LAPM or buffer.
\Qn Flow Control of DTE
\Q0, \Q5, \Q6
Disables flow control of DTE. \Q1, \Q4 Enables XON/XOFF flow control. \Q2, \Q3 Modem raises and lowers CTS to start
and stop flow control.
\Qn Flow Control of Modem
\Q0, \Q2, \Q4
Disables flow control of modem.
\Q1, \Q5 Enables XON/XOFF flow control. \Q3, \Q6 Modem starts and stops flow control
based upon state of DTEs RTS signal.
AT COMMANDS (continued)
\Tn No Data Disconnect Timer
\T0 Disables no data disconnect timer.
\Tn Sets no data disconnect timer to a value
from 1 minute to 255 minutes.
\Xn XON/XOFF Passthrough
\X0 Disables transmission of flow control
characters to remote modem.
\X1 Enables transmission of flow control
characters to remote modem.
%An Sets error control fallback character n to
an ASCII value from 0 to 127.
%Bn Sets modulation to V.34 and VF rate to n
(300, 1200, or 2400 to 33600 in increments of 2400). Default is %B33600.
%BLn Sets modulation to V.32bis and VF rate to
n (2400 to 19200 in increments of 2400)
%Cn MNP 5 Data Compression
%C0 Disables MNP5 data compression.
%C1 Enables MNP5 data compression.
%Rn Sets DTE rate for Asynchronous mode to
n (300, 1200, 2400, 4800, 7200, 9600,
12000, 14400, 19200, 28800, 38400, 57600, 76800, or 115200).
#DMn SDC Delay Minimization
#DM0 Only whole frames transmitted to DTE.
#DM1 Partial frames transmitted to DTE as
received.
#Qn Sync Flow Ctrl
#Q0 No flow control.
#Q1 Flow control using TX clock. #Q2 Flow control using CTS.
#SCn Sync Comp Mode
#SC0 Disable SDC.
#SC1 Enable SDC.
IHn V.42 bis Data Compression IH0 Disables V.42 bis data compression. IH1 Enables V.42 bis data compression for
transmit only.
IH2 Enables V.42 bis data compression for
receive only.
IH3 Enables V.42 bis data compression
in both the transmit and receive directions.
ILn Disconnect at 300 bps IL0 Disable IL1 Enable
Page 21
19
RESULT CODES
Numbers(1) Numbers(2) Words
0 0 OK 1 1 CONNECT 2 2 RING 3 3 NO CARRIER 4 4 ERROR
Result Codes 5–14, 16, 19 are enabled with the X1, X2, X3, and X4 commands. 5 5 CONNECT 1200 6 6 NO DIALTONE 7 7 BUSY 8 8 NO ANSWER
10 10 CONNECT 2400 1 1 1 1 CONNECT 4800 12 12 CONNECT 9600 13 16 CONNECT 12000 14 13 CONNECT 14400 15 14 CONNECT 19200 16 15 CONNECT 7200 17 17 CONNECT 16800 19 1 CONNECT 300
Result Codes 20–27, 29, and 37–48 are enabled with the X5 command (EC suffix) or the X6 command (V.42 or MNP suffix).
20 10 CONNECT 2400/EC 21 1 1 CONNECT 4800/EC 22 12 CONNECT 9600/EC 23 16 CONNECT 12000/EC 24 13 CONNECT 14400/EC 25 17 CONNECT 16800/EC 26 15 CONNECT 7200/EC 27 5 CONNECT 1200/EC 29 14 CONNECT 19200/EC 37 37 CONNECT 21600 38 38 CONNECT 24000 39 39 CONNECT 26400 40 40 CONNECT 28800 41 41 CONNECT 31200 42 42 CONNECT 33600 43 43 CONNECT 21600/EC 44 44 CONNECT 24000/EC 45 45 CONNECT 26400/EC 46 46 CONNECT 28800/EC 47 47 CONNECT 31200/EC 48 48 CONNECT 33600/EC
Result Codes 15, 28–34 are enabled with the X7 command (DTE rate suffix).
28 28 CONNECT 38400 30 30 CONNECT 57600 32 32 CONNECT 76800 34 34 CONNECT 115200
DIAL COMMAND MODIFIERS
T Tone Dial (DTMF) P Pulse Dial
, Pause
W Wait for Dial Tone
R Reverse Dial
@ Quiet Answer
! Hook Flash ; Return to Command Mode
Page 22
20
S-REGISTERS
Register Description Factory Setting Range
S0 Auto-Answer Ring Number 1 0(Disable) or 1–255 rings S2 A T Escape Character 43(+) 0–127 ASCII S3 Carriage Return Character 13 0–127 ASCII S4 Line Feed Character 10 0–127 ASCII S5 Backspace Character 8 0–127 ASCII S6 Blind Dial Pause 2 2–255 seconds S7 No Answer Time-out 45 1–255 seconds S8 “,” Pause Time for the Dial Modifier 2 0–255 seconds S10 No Carrier Disconnect 2 0–254 (10ths of a second) or 255(Disable) S12 Escape Sequence Guard Time 50 0–255 in 20-millisecond increments S14 Asymmetric Rate (Dial) 0 0=Enable; 1=Disable S15 Asymmetric Rate (Leased) 0 0=Enable; 1=Disable S18 Test Time-out 0(disabled) 0–255 seconds S23 Proactive Retrain 0 0=Enable; 1=Disable S25 AutoSync Start Pause 0(disabled) 0–30 seconds S26 RTS/CTS Delay 0 0–255 seconds S28 SDC Negotiation 0 0=LAPM_Buffer; 1=LAPM_Discon S29 SDC Idle Fill 0 0=Flag_Fill; 1=Mark_Fill S30 Sync DTE Rate 0 0=12800 bps; 1=115200; 3=96000; 4=78800;
5=72000; 6=64000; 7=57600; 8=56000; 9=48000; 10=38400; 11=28800; 12=19200; 13=14400;
14=9600; 15=4800; 16=2400; 17=1200 S31 SDC Bit Encoding 0 0=NRZ; 1=NRZI S32 Sync DTE CRC 0 0=Ignore; 1=CRC16 S33 Buffer Size In Buffer Mode 0 0=Normal; 1=Minimized S35 Auto Redial 0 0=Dir1; 1=Dirs1–2; 2=Dirs1–3... 9=Dirs1–10 S36 Rate Auto Originate 0 0(Disable) or 1(4800) – 6(16,800) S37 Auto Redial 0 0(Dir 1) – 9(Dirs 1–10) S38 DTR Cont Repeat 0 0=Disable, 1=Enable S39 RX Buffer Disconnect Delay 0 0(Disable) or 1–255 seconds S40 Auto Make Busy 0 0=Disable, 1=Enable S41 Dial Line Rate 29 1=14400(V.32bis); 2=12000(V.32bis);
3=9600(V .32bis); 4=7200(V.32bis);
5=4800(V .32bis); 6=2400(V.22bis); 7=1200(V .22);
8=1200(212A); 10=0–300(V .21); 11=0–300(103J);
20=19200(V .32terbo); 21=16800(V .32terbo);
27=33600(V .34); 28=31200(V.34);
29=28800(V .34); 30=26400(V.34);
31=24000(V .34); 32=21600(V.34);
33=19200(V .34); 34=16800(V.34);
35=14400(V .34); 36=12000(V.34);
37=9600(V .34); 38=7200(V.34); 39=4800(V .34);
40=2400(V.34)
Page 23
21
S-REGISTERS (continued)
Register Description Factory Setting Range
S43 Train Time 0 0=Long; 1=Short S44 Leased-Line Rate 27 1=14400(V.32bis); 2=12000(V.32bis);
3=9600(V .32bis); 4=7200(V.32bis);
5=4800(V .32bis); 6=2400(V22bis);
18=19200(V .32terbo); 19=16800(V .32terbo);
25=33600(V .34); 26=31200(V.34);
27=28800(V .34); 28=26400(V.34);
29=24000(V .34); 30=21600(V.34);
31=19200(V .34); 32=16800(V.34);
33=14400(V .34); 34=12000(V.34);
35=9600(V .34); 36=7200(V.34); 37=4800(V .34);
38=2400(V.34) S45 Leased TX Level 0 0dBm–15dBm S46 Auto Dial Backup 0 0=Disable; 1=Enable S47 Auto Dial Standby 0 0=Disable; 1=15 minutes; 2=1 hour; 3=4 hours;
255=Test(2min) S48 Leased-Line Carrier On Level 0 0=–43dBm; 1=–26dBm S49 Buffer Disconnect Delay 10 0=Disable or 1–255 in 1-second increments S51 DTE RL (CT140) 0 0=Disable; 1=Enable S52 DTE LL (CT141) 0 0=Disable; 1=Enable S53 V.54 Address 0 0(Disable) or 1–34 S54 V.54 Device T ype 0 0=Peripheral; 1=Intermediate S55 Access from Remote 0 0=Enable; 1=Disable S56 Remote Access Password 00 00–99
1st and 2nd digits
S57 Remote Access Password 00 00–99
3rd and 4th digits
S58 Remote Access Password 00 00–99
5th and 6th digits
S59 Remote Access Password 00 00–99
7th and 8th digits S61 CT11 1 Rate Control 0 0=Ignore; 1=Fallback 1; 2=Fallback 2 S62 V.25bis Coding 0 0=ASCII; 1=EBCDIC S63 V.25bis Idle Character 0 0=Mark; 1=Flag S64 V.25bis New Line Character 0 0=CR+LF; 1=CR; 2=LF S66 NMS Call Messages 0 0=Call Connect & Progress; 1=Disable;
2=Call Connect Only; 3=Call Progress Only S67 Directory Location 1 Callback 0 0=Disable; 1=Enable S69 Make Busy Via DTR 0 0=Disable; 1=Enable S74 Network Position 0 0=Tributary; 1=Control S75 Network Management Address 255 0–255 (001–256) S76 Dial Autorate 0 0=Enable; 1=Disable; 2=Start at 4800;
3=Start at 9600
Page 24
22
S-REGISTERS (continued)
Register Description Factory Setting Range
S77 DTR Alarm Reporting 0 0=Disable; 1=Enable S78 Dial Automode 0 0=Enable; 1=Disable; 2=System85 S80 No Data Disc Trigger Signal 3 0=RX or TX; 1=TX; 2=RX; 3=TX and RX S82 Leased Autorate 0 0=Enable; 1=Disable S83 MI/MIC Dialing 0 0=Disable; 1=Enable S84 AT Command Mode 0 0=Normal; 1=No Error; 2=No Strap or ERROR S85 Fast Disconnect 0 0=Disable; 1=Enable S88 Straps When Disconnected 0 0=No Change; 1=Reload; 2=Reload, No Change S89 V.42 ARQ Window Size Increase 0 0(6 frames) – 9(15 frames) S90 DTE Rate = VF Rate 0 0=Disable; 1=Enable S91 Cellular Enhancement (if ETC installed) 0 0=Disable; 1=Enable S92 V.29 Train On Data (if V.29 installed) 0 0=Disable; 1=Enable S93 RJ11 Cellular Adapt (if ETC installed) 0 0=Disable; 1=Enable
Page 25
23
Important Safety Instructions
1. Read and follow all warning notices and instructions marked on the product or
included in the manual.
2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable
operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.
3. Do not allow anything to rest on the power cord and do not locate the product
where persons will walk on the power cord.
4. Do not attempt to service this product yourself, as opening or removing covers may
expose you to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel.
5. General purpose cables are used with this product for connection to the network.
Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the customer.
6. When installed in the final configuration, the product must comply with the
applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance.
7. A rare phenomenon can create a voltage potential between the earth grounds of
two or more buildings. If products installed in separate buildings are interconnected, the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the products.
8. Input power to this product must be provided by one of the following: (1) a UL
Listed/CSA certified power source with a Class 2 or Limited Power Source (LPS) output for use in North America, or (2) a certified transformer, with a Safety Extra Low Voltage (SELV) output having a maximum of 240 VA available, for use in the country of installation.
9. In addition, since the equipment is to be used with telecommunications circuits,
take the following precautions:
Never install telephone wiring during a lightning storm.Never install telephone jacks in wet locations unless the jack is specifically
designed for wet locations.
Never touch uninsulated telephone wires or terminals unless the telephone
line has been disconnected at the network interface.
Use caution when installing or modifying telephone lines.Avoid using a telephone (other than a cordless type) during an electrical storm.
There may be a remote risk of electric shock from lightning.
Do not use the telephone to report a gas leak in the vicinity of the leak.
Page 26
24
Notices
!
WARNING:
THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT. THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND, IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE.THE AUTHORITY TO OPERATE THIS EQUIPMENT IS CONDITIONED BY THE REQUIREMENTS THAT NO MODIFICATIONS WILL BE MADE TO THE EQUIPMENT UNLESS THE CHANGES OR MODIFICATIONS ARE EXPRESSLY APPROVED BY PARADYNE.
!
WARNING:
TO USERS OF DIGITAL APPARATUS IN CANADA:THIS CLASS A DIGITAL APPARATUS MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCEĆCAUSING EQUIPMENT REGULATIONS.
CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTES LES EXIGENCES DU RÈGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA.
Government Requirements
Certain governments require that instructions pertaining to connection to the telephone network be included in the installation and operation manual. Specific instructions are listed in the following sections.
Note that 3810Plus and 3811Plus are the model names for the model numbers 3980 and 3981, respectively. The modems collectively are called 3800Plus modems.
United States – Notice to Users of the Telephone Network
1. This equipment complies with Part 68 of the FCC rules. On the equipment is a label
that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. The label is located on the bottom of the Model 3810Plus modem and on the circuit card assembly of the Model 3811Plus. If requested, this information must be provided to the telephone company.
2. For the standalone modems, the Universal Service Order Code (USOC) for
Permissive mode is RJ1 1C; the Canadian equivalent is CA11. For the carrier-mounted modem, the USOC for Permissive mode is RJ21X (Canadian CA21A).
Page 27
25
3. The Ringer Equivalence (REN) is used to determine the quantity of devices which
may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total RENs, contact the telephone company to determine the maximum RENs for the calling area.
4. If the 3800Plus modem causes harm to the telephone network, the telephone
company will notify you in advance that temporary discontinuance of service may be required. But if advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
5. The telephone company may make changes in its facilities, equipment, operations,
or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service.
6. If you experience trouble with this equipment, please contact your sales or service
representative (as appropriate) for repair or warranty information. If the product needs to be returned to the company service center for repair, contact them directly for return instructions using one of the following methods:
Via the Internet: Visit the Paradyne World Wide Web site at
http://www.paradyne.com
Via Telephone: Call our automated call system to receive current information
via fax or to speak with a company representative.
Within the U.S.A., call 1-800-870-2221 Outside the U.S.A., call 1-727-530-2340
If the trouble is causing harm to the telephone network, the telephone company may request that you remove the equipment from the network until the problem is resolved.
7. The user is not authorized to repair or modify the equipment.
8. This equipment cannot be used on public coin service provided by the telephone
company. Connection to Party Line Service is subject to state tariffs. (Contact the state public utility commission, public service commission or corporation commission for information.)
9. The Telephone Consumer Protection Act of 1991 makes it unlawful for any person
to use a computer or other electronic device to send any message via a telephone fax machine unless such a message clearly contains, in a margin at the top or bottom of each transmitted page, or on the first page of the transmission, the date and time it is sent, and an identification of the business, or other entity, or other individual sending the message, and the telephone number of such business, or other entity, or individual.
In order to program this information, follow the steps outlined in the manual supplied with your fax software.
Page 28
26
10. An FCC compliant telephone cord with modular plugs may be provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant.
Canada Notice to Users of the Telephone Network
The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the users satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the companys inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone line and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
CAUTION:
Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
The Load Number for this equipment is on the label on the modem. The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all devices does not exceed 100.
If your equipment is in need of repair, refer to the procedure in the Government Requirements and Equipment Return section.