Paradyne BitStorm 2600 IP DSLAM, bitstorm 2600 Installation Manual

Page 1
BitStorm® 2600
IP DSLAM
Installation Guide
Document No. 2600-A2-GN20-50
April 2005
Page 2
A April 2005 2600-A2-GN20-50
Copyright 2005 Paradyne Corporation. All rights reserved. Printed in U.S.A.
Notice
This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773.
Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes.
Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual.
Warranty, Sales, Service, and Training Information
Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:
Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at
www.paradyne.com/warranty.)
Telephone: Call our automated system to receive current information by fax or to speak with a company
representative.
— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A., call 1-727-530-2340
Document Feedback
We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.
Trademarks
Acculink, ADSL/R, Bitstorm, Comsphere, DSL the Easy Way, ETC, Etherloop, FrameSaver, GranDSLAM, GrandVIEW, Hotwire, the Hotwire logo, iMarc, Jetstream, MVL, NextEDGE, Net to Net Technologies, OpenLane, Paradyne, the Paradyne logo, Paradyne Credit Corp., the Paradyne Credit Corp. logo, Performance Wizard, ReachDSL, StormPort, TruePut are registered trademarks of Paradyne Corporation.
Connect to Success, Hotwire Connected, JetFusion, JetVision, MicroBurst, PacketSurfer, Quick Channel, Reverse Gateway, Spectrum Manager, and StormTracker are trademarks of Paradyne Corporation.
All other products or services mentioned herein are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners.
Page 3
2600-A2-GN20-50 April 2005 B
Software and Firmware License Agreement
The terms and conditions of this License Agreement (the “Agreement”) will apply to the software and/or firmware (individually or collectively the “Software”) incorporated into the Paradyne product (the “Product”) purchased by you and any derivatives obtained from the Software, including any copy of either. If you have executed a separate written agreement covering the Software supplied to you under this purchase, such separate written agreement shall govern.
Paradyne Corporation (“Paradyne”) grants to you, and you (“Licensee”) agree to accept a personal, non-transferable, non-exclusive, right (without the right to sublicense) to use the Software, solely as it is intended and solely as incorporated in the Product purchased from Paradyne or its authorized distributor or reseller under the following terms and conditions:
1. Ownership: The Software is the sole property of Paradyne and/or its licensors. The Licensee acquires no title, right or interest in the Software other than the license granted under this Agreement.
2. Licensee shall not use the Software in any country other than the country in which the Product was rightfully purchased except upon prior written notice to Paradyne and an agreement in writing to additional terms.
3. The Licensee shall not reverse engineer, decompile or disassemble the Software in whole or in part.
4. The Licensee shall not copy the Software except for a single archival copy.
5. Except for the Product warranty contained in the manual, the Software is provided “AS IS” and in its present state and condition and Paradyne makes no other warranty whatsoever with respect to the Product purchased by you. THIS AGREEMENT EXPRESSLY EXCLUDES ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, OR ORAL OR WRITTEN, INCLUDING WITHOUT LIMITATION:
a. Any warranty that the Software is error-free, will operate uninterrupted in your operating environment, or is
compatible with any equipment or software configurations; and
b. ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT.
Some states or other jurisdictions do not allow the exclusion of implied warranties on limitations on how long an implied warranty lasts, so the above limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from one state or jurisdiction to another.
6. In no event will Paradyne be liable to Licensee for any consequential, incidental, punitive or special damages, including any lost profits or lost savings, loss of business information or business interruption or other pecuniary loss arising out of the use or inability to use the Software, whether based on contract, tort, warranty or other legal or equitable grounds, even if Paradyne has been advised of the possibility of such damages, or for any claim by any third party.
7. The rights granted under this Agreement may not be assigned, sublicensed or otherwise transferred by the Licensee to any third party without the prior written consent of Paradyne.
8. This Agreement and the license granted under this Agreement shall be terminated in the event of breach by the Licensee of any provisions of this Agreement.
9. Upon such termination, the Licensee shall refrain from any further use of the Software and destroy the original and all copies of the Software in the possession of Licensee together with all documentation and related materials.
This Agreement shall be governed by the laws of the State of Florida, without regard to its provisions concerning conflicts of laws.
ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT. BY USING THE PARADYNE PRODUCT YOU SHOW YOUR ACCEPTANCE OF THE TERMS OF THIS LICENSE AGREEMENT.
IN THE EVENT THAT YOU DO NOT AGREE WITH ANY OF THE TERMS OF THIS LICENSE AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT IN ITS ORIGINAL PACKAGING AND YOUR SALES RECEIPT OR INVOICE TO THE LOCATION WHERE YOU OBTAINED THE PARADYNE PRODUCT OR THE LOCATION FROM WHICH IT WAS SHIPPED TO YOU, AS APPLICABLE, AND YOU WILL RECEIVE A REFUND OR CREDIT FOR THE PARADYNE PRODUCT PURCHASED BY YOU.
Page 4
C April 2005 2600-A2-GN20-50
Important Safety Instructions
1. Read and follow all warning notices and instructions marked on the product or included in the manual.
2. This product is intended to be used with a 3-wire grounding type plug — a plug that has a grounding pin. This is a safety feature. Equipment grounding is vital to ensure safe operation. Do not defeat the purpose of the grounding type plug by modifying the plug or using an adapter. Prior to installation, use an outlet tester or a voltmeter to check the AC receptacle for the presence of earth ground. If the receptacle is not properly grounded, the installation must not continue until a qualified electrician has corrected the problem.
If a 3-wire grounding type power source is not available, consult a qualified electrician to determine another method of grounding the equipment.
3. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.
4. Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord.
5. Do not attempt to service this product yourself, as it will void the warranty. Opening or removing covers may expose you to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel.
6. General purpose cables are described for use with this product. Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the customer. To reduce the risk of
fire, use a UL Listed or CSA Certified, minimum No. 26 AWG (0.128 mm
2
) telecommunication cable, or
comparable cables certified for use in the country of installation.
7. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance.
8. A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings. If products installed in separate buildings are interconnected, the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the products.
9. In addition, if the equipment is to be used with telecommunications circuits, take the following precautions:
— Never install telephone wiring during a lightning storm.
— Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
— Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the
network interface.
— Use caution when installing or modifying telephone lines.
— Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of
electric shock from lightning.
— Do not use the telephone to report a gas leak in the vicinity of the leak.
10. CLASS 1 LASER PRODUCT: This product has provisions for the customer to install a Class 1 laser transciever,
which provides optical coupling to the telecommunication network. Once a Class 1 laser product is installed, the equipment is to be considered to be a Class 1 Laser Product (Appareil à Laser de Classe 1). The customer is responsible for selecting and installing the laser transciever and for insuring that the Class 1 AEL (Allowable Emission Limit) per EN/IEC 60825 is not exceeded after the laser transponders have been installed. Do not install laser products whose class rating is greater than 1. Refer to all important safety instructions that accompanied the transciever prior to installation. Only laser Class 1 devices, certified for use in the country of installation by the cognizant agency are to be utilized in this product.
11. Input power to the ALARM relay interface (located on the front panel of the enclosure) must not exceed 30V rms or 60 VDC.
12. The equipment is intended for installation in a max. 50° C ambient temperature, in an environment that is free of dust and dirt.
!
Page 5
2600-A2-GN20-50 April 2005 D
13. The power supply cord for countries other than North America is to be a minimum H05 V V-F type, min. 0.75 mm2, 2-conductor and earth ground terminated in an IEC 320 connector on one end, and a plug which is certified for use in the country of installation at the other end.
14. Do not physically stack more than eight (8) 26x1 units high. Physical stability has not been evaluated for stacking higher than eight units, and any configuration greater than eight may result in an unstable (tip-over) condition. Ensure that the four (4) rubber feet supplied with the product have been installed on the bottom of each unit prior to stacking any 26x1 units on top of one another.
EMI Notices
UNITED STATES – EMI NOTICE:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation.
If the equipment includes a ferrite choke or chokes, they must be installed per the installation instructions.
CANADA – EMI NOTICE:
This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du réglement sur le matérial brouilleur du Canada.
Notices to Users of the Canadian Telephone Network
NOTICE: This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation IC before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada approved the equipment.
NOTICE: The Ringer Equivalence Number (REN) for this terminal equipment is labeled on the equipment and includes the effect of the POTS splitter. The REN assigned to each terminal equipment provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed five.
When the equipment is used in a customer premises environment, a Model 6051 POTS Splitter must be used to ensure CS-03 compliance. Refer to the POTS splitter installation instructions for details.
CE Marking
When the product is marked with the CE mark on the equipment label, a supporting Declaration of Conformity may be downloaded from the Paradyne World Wide Web site at www.paradyne.com. Select Library Technical Manuals
CE Declarations of Conformity.
!
!
Page 6
E April 2005 2600-A2-GN20-50
Japan
Class A ITE
This is a Class A product based on the standard of the Voluntary Control Council for interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
Page 7
2600-A2-GN20-50 April 2005 i
Contents
Software and Firmware License Agreement . . . . . . . . . . . . . . . . . . . . B
About This Guide
Document Purpose and Intended Audience . . . . . . . . . . . . . . . . . . . . iii
Document Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Related Product Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
1 Installation
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Preparation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Cables Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Unpacking the Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Mounting Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Installing the Brackets for Rack Mounting . . . . . . . . . . . . . . . . . . . . . . 1-6
Installing the BitStorm 2600 Into a Rack . . . . . . . . . . . . . . . . . . . . . . . 1-8
Installing the BitStorm 2600 on a Wall . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
Installing the BitStorm 2600 on a Shelf or Desktop . . . . . . . . . . . . . . . 1-12
2 Cabling
Cabling Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
DSL Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
GigE Uplink (Port 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
10/100BaseT Uplink (Port 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
T1 or E1 Uplink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Chaining BitStorm 2600s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Management Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Connecting a Terminal or PC to the Console Port. . . . . . . . . . . . . 2-8
Connecting a Modem to the Console Port. . . . . . . . . . . . . . . . . . . 2-9
Alarm Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Page 8
Contents
ii April 2005 2600-A2-GN20-50
Connecting to Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
3LEDs
LED Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
LED Meanings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
4 Configuration
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Using the CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Configure Management Default Gateway Address . . . . . . . . . . . . 4-2
Configure Management Inband Address . . . . . . . . . . . . . . . . . . . . 4-3
Configure Management Out-of-Band Address . . . . . . . . . . . . . . . 4-3
BitStorm 2600 Startup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Management Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Startup Procedure for Inband Management . . . . . . . . . . . . . . . . . . . . . 4-5
Changing the VLAN for Inband Management . . . . . . . . . . . . . . . . 4-5
Startup Procedure for Out-of-Band Management . . . . . . . . . . . . . . . . 4-7
Using the Web Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
System / Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Configuration / Management / SNMP . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
A Connectors and Pin Assignments
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
DSL Ports and POTS Splitter Connectors . . . . . . . . . . . . . . . . . . . . . . A-2
Port 1 and Port 2 10/100BaseT Connectors . . . . . . . . . . . . . . . . . . . . A-3
Port 3 1000BaseT Connector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
Port 3 GigE SFP Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4
E1 and T1 Uplink Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5
Console Port Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-5
ALARM Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-6
B Equipment List
C Technical Specifications
Index
Page 9
2600-A2-GN20-50 April 2005 iii
About This Guide
Document Purpose and Intended Audience
This document is written for technicians who install the BitStorm® 2600 IP DSLAM.
Document Summary
A master glossary of terms and acronyms used in Paradyne documents is available on the World Wide Web at www.paradyne.com. Select Support
Technical Manuals Technical Glossary.
Section Description
Chapter 1, Installation Describes the physical installation of the BitStorm 2600 into
a rack.
Chapter 2, Cabling Describes how to install all cables for the BitStorm 2600.
Chapter 3, LEDs Explains the meaning and usage of the front panel LEDs.
Chapter 4, Configuration Describes the minimal configuration steps required to
prepare the BitStorm 2600 for remote access, using the command line interface and web interface.
Appendix A, Connectors
and Pin Assignments
Provides pinouts for connectors on the BitStorm 2600.
Appendix B, Equipment List Provides part numbers for the BitStorm 2600 and related
products.
Appendix C, Technical
Specifications
Lists the technical characteristics of the BitStorm 2600.
Index Lists key terms, acronyms, concepts, and sections in
alphabetical order.
Page 10
About This Guide
iv April 2005 2600-A2-GN20-50
Related Product Documents
Documentation for the BitStorm 2600 IP DSLAM is available on the World Wide Web at www.paradyne.com. Select Support Technical Manuals.
To order a paper copy of a Paradyne document, or to talk to a sales representative, please call 727-530-2000.
Document Number Document Title
2600-A2-GB21 BitStorm 2600 and GranDSLAM 4200 IP DSLAM Command
Line Interface Reference
Describes the Command Line Interface (CLI) used to configure and monitor the BitStorm 2600 IP DSLAM.
2600-A2-GB22 BitStorm 2600 and GranDSLAM 4200 IP DSLAM SNMP
Reference
Contains the information necessary to use Simple Network Management Protocol (SNMP) to configure and monitor the BitStorm 2600 IP DSLAM.
2600-A2-GT20 BitStorm 2600 and GranDSLAM 4200 Training Guide
Describes how to configure the BitStorm 2600 IP DSLAM for triple play (video, voice, and data).
6051-A2-GZ40 BitStorm 6051 POTS Splitter Installation Instructions
Describes how to install the BitStorm 6051 POTS splitter.
6210-A2-GB20 Hotwire 6210-A2, 6211-A2, and 6381-A2 User’s Guide
Describes the installation and operation of the 6210 ADSL bridge, 6211 ADSL router, and 6381 ADSL/R router.
7890-A2-GB22 GrandVIEW EMS User’s Guide
Contains instructions for maintaining network services and resources using the GrandVIEW Element Management System (EMS).
Page 11
2600-A2-GN20-50 April 2005 1-1
1
Installation
Overview
The BitStorm® 2600 is a family of stackable IP DSLAMs designed for installation in a Central Office (CO), multi-tenant unit (MTU), multi-dwelling unit (MDU), or remote terminal environment. The BitStorm 2600 is available with or without internal POTS splitters.
The ReachDSL™ Models 2611 and 2614 are interoperable with the Hotwire
®
6381 ADSL/R modem, as well as with all other Customer Premises Equipment (CPE) containing Asymmetric Digital Subscriber Line/ReachDSL (ADSL/R™) chipsets. The 2614 models support E1 or T1 MLPPP.
The ADSL Models 2621 and 2624 are interoperable with the Hotwire 6381
ADSL/R modem, as well as any standard ADSL CPE. They support ADSL Annex A, including ADSL2 and ADSL2+. The 2624 models support E1 or T1 MLPPP.
The ADSL Model 2631 supports ADSL Annex B, including ADSL2 and
ADSL2+.
The SHDSL Model 2671 and 2674 are interoperable with any standard
SHDSL CPE. They support SHDSL (G.991.2). The 2674 models support E1 or T1 MLPPP.
See Appendix B, Equipment List for a description of all available models.
User interfaces include a Command Line Interface (CLI) and a web browser interface. The unit also may be managed using a network manager such as the Paradyne GrandVIEW
®
Element Management System (EMS).
03-17435
PORT1-10/100BT
CONSOLE
PORT2-10/100BT PORT3
LINK
ACT
GigE
STATUS
ALARM
TEST
ALARM
1
2
2
3
DSL PORTS 1-24
1000BT
2
4
3
4
5
6
7
8
9
1 0
1
1
1
2
13
1
4
1
5
16
1
7
1
8
1
9
2
0
2
1
2
2
POTS 1-24
2
6
00
Page 12
1. Installation
1-2 April 2005 2600-A2-GN20-50
Up to eight BitStorm 2600 units can be logically stacked, with aggregation for up to 192 ports of DSL traffic. ReachDSL, ADSL, and SHDSL units can be included in the same stack.
Preparation
Consider the following before installing the BitStorm 2600 IP DSLAM:
Installation Site
Your installation site should be well ventilated, clean, and free of environmental extremes.
Installation Options
The BitStorm 2600 may be:
— Mounted with the included mounting brackets in a standard 19-inch
(483 mm) or 23-inch (584 mm) rack (including both Bay Networks and Nortel 23-inch racks), or, with separately purchased mounting brackets, in a 21-inch (535 mm) ETSI rack. ETSI brackets are available from Paradyne. See Appendix B, Equipment List.
As many BitStorm 2600 units may be mounted in a standard rack as there are 1.75-inch (44.45 mm) spaces in the rack, so long as adequate cooling is provided.
— Mounted vertically against a wall.
The standard mounting brackets provided can be fastened to the base of the unit for wall mounting.
— Set on a shelf or desktop.
Up to five BitStorm 2600 units may be stacked on a shelf or desktop. Different models can be mixed in a stack.
Power
The BitStorm 2600 operates from a 90 to 265 VAC, 47 to 63 Hz power source.
Other Cabling
No cables are provided with the BitStorm 2600. See Ta bl e 1 - 1, Ca b le
Descriptions, to determine what cables you need to obtain before installation.
Page 13
1. Installation
2600-A2-GN20-50 April 2005
1-3
Cables Required
Ta bl e 1- 1 shows all the cables that may be required for your installation.
Table 1-1. Cable Descriptions
Connector Name Connector and Cable For Connecting . . .
DSL PORTS 1–24
POTS 1–24
50-pin RJ21X Telco-type straight connector and 50-wire cable. Two cables required, one for DSL and one for POTS (if used).
Up to 24 DSL ports to Main Distribution Frame, punchdown block, or splitters.
Up to 24 POTS splitter ports to Main Distribution Frame or punchdown block.
Por t 3 GigE
SFP Transceiver An upstream BitStorm 2600 to a
downstream BitStorm 2600, or a downstream BitStorm 2600 to an upstream BitStorm 2600 or network.
Por t 3 1000BT
8-position modular plug and 8-wire Category 5 or better unshielded twisted pair (UTP) cable.
Port 2 10/100BT 8-position modular plug and
8-wire Category 5 or better unshielded twisted pair (UTP) cable.
Port 1 10/100BT 8-position modular plug and
8-wire Category 5 or better unshielded twisted pair (UTP) cable.
A Network Management System (NMS) over a Local Area Network (LAN) employing 10BaseT or 100BaseT.
T1/E1 Ports 1–8 From one to eight 8-position
modular plug and 8-wire Category 5 or better unshielded twisted pair (UTP) cables.
A BitStorm 2600 to a T1/E1 bridged PPP or MLPPP uplink interface.
CONSOLE DB9 plug connector and
shielded cable.
The other connector
depends on the serial port on your terminal or PC, but normally is a DB9 socket.
The other connector
depends on the serial port on your modem, but normally is a DB25 plug. A null modem (crossover) cable is required.
The BitStorm 2600 to one of the following:
A terminal or a PC with a
terminal emulation program, or
A modem.
ALARM 5-position terminal block and
shielded, twisted-pair cable.
The BitStorm 2600 to an alarm system.
Page 14
1. Installation
1-4 April 2005 2600-A2-GN20-50
Unpacking the Hardware
HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static control precautions to prevent damage to equipment. If you are not sure of the proper static control precautions, contact your nearest sales or service representative.
The BitStorm 2600 is shipped in a cardboard shipping container. Carefully remove the unit from its shipping container and check for physical damage. If the unit shows signs of shipping damage, notify your sales representative.
Package Contents
In addition to this installation guide, the BitStorm 2600 shipping carton should contain:
BitStorm 2600 DSLAM
AC Power Cable
Two sets of mounting brackets: one set suitable for a 19-inch (483 mm) rack
and one set suitable for a 23-inch (584 mm) rack (including Bay Networks and Nortel)
Hardware kit (see Table 1-2, Contents of Hardware Kit Shipped with the
BitStorm 2600)
If anything is missing, notify your sales representative.
Before installing the BitStorm 2600, read the Important Safety Instructions in the beginning of this document.
Be sure to register your warranty at www.paradyne.com/warranty.
!
Page 15
1. Installation
2600-A2-GN20-50 April 2005
1-5
Table 1-2. Contents of Hardware Kit Shipped with the BitStorm 2600
Appearance Description Quantity
Flat-head screw for attaching 19" mounting brackets to unit
6
Machine screw with captive starwasher (6-32 x 1/4) for attaching 23" mounting brackets to unit
6
Self-retaining nut for racks without threaded holes 4
Dress screw (12-24 x 1/2) for use with self-retaining nuts
4
Machine screw with captive starwasher (10-32 x 1/2″) for use with racks with threaded holes
4
Captive pan-head screw for replacing long Telco screw 2
Rubber foot for desk-mount and stacking of units 4
Cable tie (8) for strain relief and cable management 2
5-position plug for ALARM connection 1
02-17259
02-17326
02-17256
02-17257
02-17258
02-17325
02-17261
02-17262
02-17327
Page 16
1. Installation
1-6 April 2005 2600-A2-GN20-50
Mounting Configurations
Three basic installation configurations are available:
Rack mount – see Installing the Brackets for Rack Mounting on page 1-6 and
Installing the BitStorm 2600 Into a Rack on page 1-8.
Wall mount – see Installing the BitStorm 2600 on a Wall on page 1-10.
Shelf or desktop – see Installing the BitStorm 2600 on a Shelf or Desktop on
page 1-12.
Mounting Brackets
Your BitStorm 2600 can be installed in a rack or on the wall using mounting brackets. Two brackets suitable for a 19-inch (483 mm) rack (marked EIA-19) and two brackets suitable for a 23-inch (584 mm) Bay Networks or Nortel rack (marked with Paradyne Part Number 868-6282-0020) are shipped with the unit. Two brackets suitable for a 21-inch (535 mm) rack (marked ETSI) are available from Paradyne as a separate feature (see Appendix B, Equipment List).
Rack-mounting brackets may also be used to attach the unit to a wall.
NOTE:
In this guide, the term rack refers to any rack, cabinet, frame, or bay suitable for mounting telecommunications equipment.
Installing the Brackets for Rack Mounting
Procedure
To install the mounting brackets for rack mounting:
1. Locate the black screw nearest the front panel on each side of the unit, as shown.
2. Remove these two black screws (one from each side) before attempting to install the mounting brackets.
03-17445
D
S
L
P
O
R
T S
1
- 2
4
P
O
T
S
1
­2
4
1
2
2 3
2
4
3
4
5
6
7
8
9
1 0
1
1
1
2
1 3
1 4
1 5
1 6
1 7
1
8
1
9
2
0
2
1
2 2
Page 17
1. Installation
2600-A2-GN20-50 April 2005
1-7
3. Identify six flat-head screws (for 19-inch racks) or six machine screws (for 23-inch racks) provided with the mounting brackets in the hardware kit.
4. Attach the brackets appropriate to your rack size. Tighten all screws firmly.
02-17324
23-inch (584 mm) EIA and Bay Networks
Rack Mount
21.1-inch (535 mm) Rack Mount
19-inch (483 mm) Rack Mount
23-inch (584 mm) Nortel
Rack Mount
Page 18
1. Installation
1-8 April 2005 2600-A2-GN20-50
Installing the BitStorm 2600 Into a Rack
Two types of mounting screws are provided. Use:
#10-32 mounting screws for rails with threaded screw holes
#12-24 mounting screws and self-retaining nuts for rails with unthreaded
screw holes
Procedure
To install the BitStorm 2600 into a rack:
1. Determine where in the rack you will mount the BitStorm 2600. If your rack does not have threaded screw holes, slip self-retaining nuts onto the rails where the BitStorm 2600 will be fastened.
2. Place the unit so that the brackets rest against the front of the rails. Insert screws in the bottom screw positions and hand-tighten them.
02-17070
Page 19
1. Installation
2600-A2-GN20-50 April 2005
1-9
3. Insert and tighten the screws in the top screw positions, then tighten the bottom screws.
03-17436
P O R T 1
­1
0 / 1 0 0 B T
C O N S O L
E
P O R T 2
­1 0 / 1 0 0 B
T
P O R T 3
L
I
N
K
A
C
T
G i g E
S
T
A
T
U
S
A
L
A
R
M
T
E
S
T
A L A R M
1
2
2 3
D S L P O R
T S 1
­2 4
1 0 0
0 B T
2 4
3
4
5
6
7
8
9
1 0
1 1
1 2
1 3
1 4
1 5
1 6
1 7
1 8
1 9
2 0
2 1
2 2
P O T S 1
- 2
4
P
O
R
T1-1
0/1
00
B
T
C
O
N
S
O
L
E
P
O
R
T
2
-1 0
/1
0
0B
T
P
O
R
T3
L
IN
K
A
C
T
G
igE
S
T
A
T
U
S
A
LA
R
M
T
E
S
T
A
LA
R
M
1
2
23
D
S
L
P
O
R
TS
1-2
4
10
0
0B
T
24
3
4
5
6
7
8
9
10
1
1
12
13
14
15
16
17
18
19
20
21
22
P
O
T
S
1
-24
Page 20
1. Installation
1-10 April 2005 2600-A2-GN20-50
Installing the BitStorm 2600 on a Wall
Wall mounting requires two wood screws suitable for the weight of the fully cabled unit. These are not included. Use at a minimum 1/4-inch (6 mm) diameter screws in 3/4-inch (19 mm) plywood (not drywall).
Procedure
To install the BitStorm 2600 on a wall:
1. Identify the flat-head screws provided in the hardware kit and the brackets suitable for a 23-inch rack. Two screws are required for each bracket.
2. Orient the unit so that the bottom is facing you and the faceplate is at the top.
3. Locate the supplied Right Side mounting bracket and fasten it to the right side of the unit.
4. Locate the supplied Left Side mounting bracket and fasten it to the left side of the unit.
5. Tighten all screws firmly.
04-17522
Page 21
1. Installation
2600-A2-GN20-50 April 2005
1-11
6. Install two wood screws (not provided) at the same height above the floor and
18.75 inches (476.25 mm) apart. Do not completely tighten the screws. Leave them so their heads are about 1/4 inch (6 mm) from the wall.
7. Hang the unit from the wood screws to verify that the screws are properly placed. The screws should freely slide into the top of the key slots in the brackets.
Do not fasten the unit to the wall until after it is completely cabled and tested.
03-17437
17.85 in (453 mm)
2600
Page 22
1. Installation
1-12 April 2005 2600-A2-GN20-50
Installing the BitStorm 2600 on a Shelf or Desktop
If the BitStorm 2600 will be placed on a shelf or desktop, install the provided rubber feet before putting the unit in position.
Procedure
To install the BitStorm 2600 on a shelf or desktop, as a standalone unit or in a stack:
1. Locate the rubber feet in the hardware kit provided with the unit.
2. Turn the unit upside down on a work surface. Squares stamped into the bottom of the unit show the proper positions for the feet.
3. Remove the protective sheet from the bottom of each foot, then press the foot onto a corner of the bottom of the unit.
4. Turn the unit right side up and place it in position on a shelf or desktop.
If the installation includes more than one unit, one can be stacked atop another. Up to five units can be stacked together.
03-17439
Page 23
2600-A2-GN20-50 April 2005 2-1
2
Cabling
Cabling Overview
The BitStorm 2600 has a large variety of possible cabling configurations. This chapter describes all possible connections, not all of which are required:
DSL Ports on page 2-2
GigE Uplink (Port 3) on page 2-3
10/100BaseT Uplink (Port 2) on page 2-4
T1 or E1 Uplink on page 2-5
Chaining BitStorm 2600s on page 2-6
Management Port on page 2-7
Console Port on page 2-8
Alarm Interface on page 2-10
Ground on page 2-11
Connecting to Power on page 2-12
Page 24
2. Cabling
2-2 April 2005 2600-A2-GN20-50
DSL Ports
The BitStorm 2600 DSL connector supports the tip and ring connections of up to 24 DSL ports over a 50-position cable.
A POTS (plain old telephone service) splitter connector is also provided, for CO applications only. The internal splitter includes an ANSI T1.413-compliant Maintenance Test Signature (MTS) circuit. If your model does not contain the integrated POTS splitter, you must connect the unit to a separate POTS splitter. The Model 6051 POTS Splitter must be used for customer premises applications in Canada.
Procedure
To cable the DSL Ports:
1. Insert a cable tie (provided) through the top of the anchor mount next to the DSL PORTS 1–24 connector.
2. If the connector for your cable has a short captive screw, attach the cable to the DSL PORTS 1–24 connector and fasten it to the jack screw with its short captive screw.
3. If the connector for your cable has a long captive screw, remove the provided jack screw from the threaded hole next to the DSL PORTS 1–24 connector. Attach the DSL PORTS 1–24 connector to the unit using the long, captive pan-head screw (provided).
Short
Screw
#4-40
Jack Screw
02-17083
Anchor
Mount
50-Pin
Connector
02-17346
Anchor
Mount
50-Pin
Connector
Long
Screw
Page 25
2. Cabling
2600-A2-GN20-50 April 2005
2-3
4. Tighten the cable tie around the connector and trim the excess.
5. If you use an internal POTS splitter, repeat Step 1 through Step 4, substituting POTS 1–24 for DSL PORTS 1–24.
6. Secure the cables as required for strain relief.
GigE Uplink (Port 3)
Port 3 comprises two interfaces, only one of which may be used at a time:
An 8-position modular jack providing support for 1000BaseT
A Small Form-Factor Pluggable (SFP) socket providing, with the appropriate
transceiver installed, support for 1000BaseX. A single-mode 1000BaseLX transceiver is available from Paradyne. See Appendix B, Equipment List.
Either interface can be used as the uplink for a single BitStorm 2600, or for the terminating unit in a stack of BitStorm 2600s.
Procedure
To use Port 3 as the uplink:
1. Connect the uplink cable to the BitStorm 2600:
For a wire connection, plug the 8-position modular plug of your uplink
cable into the Port 3 1000BT modular jack. A straight-through cable can be used regardless of the destination interface, since the port automatically distinguishes between a Medium-Dependent Interface (MDI) and an MDI Crossover (MDIX).
For a fiber connection, plug your transceiver into the Port 3 GigE SFP
socket. Plug the LC connector of your fiber optic uplink cable into the cable socket of the transceiver. Observing the minimum bend radius for your cable, fasten it with cable ties in such a way that it will not be kinked or snagged in the course of other cabling. If you do not know the specifications for your cable, maintain a radius of at least ten times the cable diameter.
02-17084
Page 26
2. Cabling
2-4 April 2005 2600-A2-GN20-50
2. Connect the other end of the uplink cable to the uplink interface, such as an Ethernet switch.
3. Port 3 (eth3) is the default uplink. If you have changed the default, use the configure uplink CLI command or the Configuration / Uplink screen of the web interface to specify eth3 as the uplink port.
10/100BaseT Uplink (Port 2)
Port 2 can be configured as the uplink for a single BitStorm 2600, or for the terminating unit in a stack of BitStorm 2600s. A straight-through cable can be used regardless of the destination interface, since the port automatically distinguishes between an MDI and an MDIX.
Procedure
To use Port 2 as the uplink:
1. Connect an 8-position modular cable to Port 2.
2. Connect the other end of the cable to the uplink interface, such as an Ethernet switch.
3. Using the configure uplink CLI command or the Configuration / Uplink screen of the web interface, specify eth2 as the uplink port.
03-17441
SFP Transceiver
LC Connector
PORT1-10/100BT
CONSOLE
PORT2-10/100BT PORT3
LINK
ACT
GigE
STATUS
ALARM
TEST
ALARM
1000BT
Page 27
2. Cabling
2600-A2-GN20-50 April 2005
2-5
T1 or E1 Uplink
Models that support T1 or E1 have eight ports that can be used in any combination to provide PPP or MLPPP uplinks.
Procedure
To use T1 or E1 uplinks:
1. Use the CLI or web interface to configure PPP or MLPPP paths.
2. Connect an 8-position modular cable to one of the eight T1 or E1 ports on the faceplate of the DSLAM. Connect the other end of the cable to the uplink interface.
3. Connect up to seven other T1 or E1 cables as in Step 2.
4. Fix the cable or cables to the rail as required for strain relief.
CAUTION:
It is possible to create bridging loops by connecting cables improperly relative to the configuration defined on the SCP card.
05-17628
CONSOLE
LINK
ACT
STATUS
ALARM
TEST
ALARM
1
2
3
4
5
6
7
8
1
2
23
24
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
PORT1-10/100BT PORT2-10/100BT
LINK
ACT
UPLINK POR
TS
Page 28
2. Cabling
2-6 April 2005 2600-A2-GN20-50
Chaining BitStorm 2600s
Up to eight BitStorm 2600s can be chained together to use a single uplink. The same port (eth2 or eth3) used as the uplink for one unit must be used as the downlink for the next. For example, in this illustration:
The top unit has Port 3 (eth3) defined as its uplink and is connected to Port 3
of the next unit in the chain using a straight-through 8-position modular cable.
The middle unit has Port 2 (eth2) defined as its uplink and is connected to
Port 2 of the next unit.
The bottom unit has Port 3 (eth3) defined as its uplink, which is the uplink for
the stack. That unit is using the fiber interface.
Copper cables connecting:
Port 2 to Port 2 must be at least 3 feet (0.9 m) long
Port 3 to Port 3 must be at least 6 feet (1.8 m) long
Shorter cables may cause data errors.
03-17440
P O
R
T
1-10
/1
0
0
B
T
C
O
N
S
O
L
E
P
O
R
T
2-10
/10
0B
T
P O
R
T3
L
IN
K
A
C
T
G
igE
S
T
A
T
U
S
A
LA
R
M
T
E
S
T
A
L
A R
M
1
2
23
D
S
L
P
O
R
T
S
1
-2 4
1
00
0B
T
24
3
4
5
6
7
8
9
10
1
1
12
13
14
15
16
17
18
19
20
21
22
P
O
T
S
1-2
4
P O
R
T1
-1 0/1
0
0B
T
C
O
N
S
O
L
E
P
O
R
T
2-1
0/1
0
0
B T
P O
R
T
3
L
IN
K
A
C
T
G
igE
S
T
A
T
U
S
A
LA
R
M
T
E
S
T
A
LA
R
M
1
2
23
D
S
L P
O
R
TS
1-2
4
1
00
0B
T
24
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
P
O
T
S
1
-24
P O
R
T
1
-1 0/10
0B
T
C
O
N
S
O
L
E
P
O
R
T
2-1
0/1
0
0B
T
P O
R
T
3
L
IN
K
A
C
T
G
ig
E
S
T
A
T
U
S
A
LA
R
M
T
E
S
T
A
LA
R
M
1
2
23
D
S
L
P
O
R
T
S
1
-24
1
00
0
B T
24
3
4
5
6
7
8
9
10
1
1
12
13
14
15
16
17
18
19
20
21
22
P
O
T
S
1
-2 4
Page 29
2. Cabling
2600-A2-GN20-50 April 2005
2-7
Management Port
Port 1 can be used to connect the BitStorm 2600 to a network management system using a 10BaseT or 100BaseT LAN. A straight-through cable can be used regardless of the destination interface, since the port automatically distinguishes between an MDI and an MDIX.
Procedure
To use Port 1 as the out-of-band management port:
1. Connect an 8-position modular cable to Port 1.
2. If the BitStorm 2600 is in a rack, fasten the cable to a rail with a cable tie.
3. Connect the other end of the cable to your Ethernet switch or a network interface card in a PC.
04-17521
Ethernet Switch
Port 1
PORT1-10/100BT
CONSOLE
PORT2-10/100BT PORT3
LIN
K
A
C
T
GigE
S
TA
T
U
S
AL
A
R
M
T
ES
T
ALARM
1
2
2
3
DSL PORTS 1-24
1000BT
2
4
3
4
5
6
7
8
9
1 0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
Page 30
2. Cabling
2-8 April 2005 2600-A2-GN20-50
Console Port
The CONSOLE port normally serves as the primary user interface with the BitStorm 2600 during installation. You can connect a terminal or PC directly to the CONSOLE port using a DTE cable (see procedure below). You can also use the CONSOLE port to attach a modem to the BitStorm 2600 for remote dial-in management of the unit using a DCE cable (see Connecting a Modem to the
Console Port on page 2-9).
Connecting a Terminal or PC to the Console Port
Procedure
To connect a terminal or PC to the CONSOLE port:
1. Configure the terminal or terminal emulation program to use the following parameters:
— Maximum speed: 9600 bps
— Data bits: 8
— Parity: None
— Flow Control: None
— Stop bits: 1
2. Determine and procure the proper Data Terminal Equipment (DTE) cable type. The CONSOLE port requires a DB9 plug connector. The other connector depends on the serial port on your terminal or PC.
3. Connect the DB9 plug connector to the CONSOLE port socket. The CONSOLE port is ordinarily used only during installation, so do not fasten the connector.
4. Connect the other end of the cable to the serial port of your terminal or PC.
PORT1-10/100BT
CONSOLE
PORT2-10/100BT PORT3
L
IN
K
A
C
T
GigE
S
T
A
T
U
S
A
L
A
R
M
T
E
S
T
ALARM
1
2
2
3
DSL PORTS 1-24
1000BT
2
4
3
4
5
6
7
8
9
1
0
1 1
1 2
1 3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2 1
2
2
03-17447
Serial
Por t
Page 31
2. Cabling
2600-A2-GN20-50 April 2005
2-9
Connecting a Modem to the Console Port
Procedure
To connect a modem to the CONSOLE port:
1. Determine and procure the proper DCE cable type for your modem. The CONSOLE port requires a DB9 plug connector. The other connector depends on the serial port on your modem, but normally a DB25 plug is required. The cable must be an EIA-232-E crossover (null modem) cable.
2. Connect the DB9 plug connector to the CONSOLE port socket.
3. If the modem will be permanently connected, fasten the connector to the Management Module with its captive screws. If the BitStorm 2600 is in a rack, dress the cable to the left and attach it to the rail with a cable tie.
4. Connect the other end of the cable to the serial port of your modem.
PORT1-10/100BT
CONSOLE
PORT2-10/100BT PORT3
LINK
ACT
GigE
STATUS
ALARM
TEST
ALARM
1
2
23
DSL PORTS 1-24
1000BT
24
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
03-17448
T ST
L IN
E
A
LM
P W
R
E
TH
E
RN
E
T
Serial Port
Modem
CONSOLE
Por t
Page 32
2. Cabling
2-10 April 2005 2600-A2-GN20-50
Alarm Interface
The ALARM interface consists of five contacts. Three of the contacts provide access to alarm relays that that can be used to set off Major and Minor physical alarms. The other two contacts provide access to a sense circuit that can be used to detect the open or closed condition of an external alarm relay.
A 5-position plug provided in the hardware kit is used to connect 20–28 AWG wire to the ALARM terminal block (see Table 1-2, Contents of Hardware Kit Shipped
with the BitStorm 2600, in Chapter 1, Installation).
The contacts are closed during normal operation. They open in response to loss of power, hardware failure, or other alarm conditions. See ALARM Connector in
Appendix A, Connectors and Pin Assignments for more information.
CAUTION:
The ALARM Sense + and Sense – contacts are intended to be connected to an external alarm relay. Do not apply power to these contacts; doing so will result in damage to the unit.
Procedure
To connect the ALARM interface:
1. Strip the tips of the alarm source wires about 1/2 inch (13 mm).
2. Use a screwdriver to press the orange spring tab in while inserting the wire into the hole below it. The insulation should be fully within the plug and no bare wire should be exposed outside of the plug.
3. Insert the plug into the ALARM interface on the front panel of the BitStorm 2600.
4. If the BitStorm 2600 is in a rack, dress the cable to the left and secure it to the rail with a cable tie.
5. Connect the other end of the cable to your alarm monitoring system.
02-17328
Spring
Ta b
Page 33
2. Cabling
2600-A2-GN20-50 April 2005
2-11
Ground
Procedure
To connect the unit to a ground:
1. Crimp a ring terminal onto the stripped end of 14 AWG or heavier copper ground wire.
2. Remove the screw marked by the ground symbol ( ) at the right side of the front panel.
3. Fasten the ring terminal to the front panel using the same screw.
4. Attach the ground wire to an earth ground.
03-17
4
POTS 1-24
To Earth Ground
2600
Page 34
2. Cabling
2-12 April 2005 2600-A2-GN20-50
Connecting to Power
The BitStorm 2600 can be powered by any AC power source supplying 90–265 VAC at 47–63 Hz.
Procedure
To connect the BitStorm 2600 to a power source:
1. Insert the supplied power cord into the power socket on the back of the unit.
2. If the BitStorm 2600 is in a rack, dress the power cord to the left and fasten it to the rail with a cable tie.
3. Connect the other end of the power cord to a grounded AC power source.
4. Make sure the STATUS LED on the front panel is ON (green). See Chapter 3,
LEDs.
02-17248
Page 35
2600-A2-GN20-50 April 2005 3-1
3
LEDs
LED Locations
The locations of the System and DSL Port LEDs on the front panel of the BitStorm 2600 are shown in Figure 3-1, Front Panel LEDs (GigE Uplink).
Figure 3-1. Front Panel LEDs (GigE Uplink)
Figure 3-2. Front Panel LEDs (T1/E1 Uplink)
03-17454
PORT1-10/100BT
CONSOLE
PORT2-10/100BT PORT3
LINK
ACT
GigE
STAT US
ALARM
TEST
ALARM
1
2
23
1000BT
24
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Link LEDs Activity LEDS DSL Ports LEDs
2
6
0
0
P O
R T
1
­1 0
/ 1
0 0
B T
C O
N S
O L
E
P
O
R T
2
­1 0
/ 1
0 0 B
T
P
O R
T
3
L
I
N
K
A
C
T
G
ig E
S
T
A
T
U
S
A
L
A
R
M
T
E
S
T
A
L A
R M
1
2
2 3
D S
L P
O R
T S
1
­2 4
1 0 0 0
B T
2 4
3
4
5
6
7
8
9
1 0
1 1
1 2
1 3
1 4
1
5
1
6
1 7
1 8
1 9
2
0
2 1
2 2
P O
T
S 1
­2 4
CONSOLE
LINK
ACT
STATUS
ALARM
TEST
ALARM
1234567
8
1
2
23
24
3456789101112131415161718192021
22
PORT1-10/100BT PORT2-10/100BT
05-17629
Link
LEDs
Activity
LEDs
Uplink
LEDs
DSL Ports
LEDs
LINK
ACT
UPLINK PORTS
Page 36
3. LEDs
3-2 April 2005 2600-A2-GN20-50
LED Meanings
When power is first applied to the unit, it performs a power-on self-test. When this test is successfully completed, the Status LED blinks. The meaning of all the LEDs is shown in Table 3-1, Front Panel LEDs.
Table 3-1. Front Panel LEDs
LED Color State Meaning
Link*
* The RJ45-type connectors for Port 1, Port 2, and (if present) Port 3 bear two LEDs:
the left one is the Link LED and the right one is the Activity LED. The SFP socket for Port 3 has two adjacent LEDs marked LINK and ACT.
Green Off
On
Flashing
No Ethernet link present.
Ethernet Link present.
Ethernet link is present, but port is administratively disabled.
Activity* Green Off
On
No data is being transferred.
Data is being transferred.
Uplink Ports 1–8 (T1/E1 models)
Green
YellowOnOn
Off
Good signal; unit is trained.
Link is in an alarm state.
Link is disabled.
STATUS Green Off
On
No power, or the unit has not completed initialization.
Unit has power and has completed initialization.
ALARM Amber Off
On
No Alarms.
An alarm is reported: the unit failed self-test, or the unit has exceeded a safe temperature, or a fan has failed, or a port is in an alarm state.
TEST Amber Off
On
Normal operating mode.
At least one port is in test mode.
DSL Ports (LEDs numbered 1–24 correspond to DSL ports 1–24)
Green Off
On
The port is disabled or no signal is detected on the line.
Port has successfully trained with the remote and is active.
Page 37
2600-A2-GN20-50 April 2005 4-1
4
Configuration
Overview
The BitStorm 2600 is designed to require minimal configuration before it can be accessed by a Network Operations Center (NOC). When the BitStorm 2600 is first powered up it is a fully functional bridge, and all DSL ports are set to their maximum speed.
Initial configuration is performed using the Command Line Interface (CLI). The CLI is available from a terminal or PC connected to the CONSOLE port.
Additional configuration may be necessary, depending on the mode used to manage the BitStorm 2600:
Inband
Out of band through Port 1
This can be performed using the CLI, SNMP, or the web interface.
For more configuration information, see the BitStorm 2600 and GranDSLAM 4200
IP DSLAM Command Line Interface Reference (for the CLI) and the online Help
(for the web interface).
Page 38
4. Configuration
4-2 April 2005 2600-A2-GN20-50
Using the CLI
A command line interface (CLI) can be used to configure and monitor the unit. The CLI is available from a PC or terminal connected to the Console port, or from a Telnet session with the device.
The following commands are available:
Descriptions of some essential configuration commands follow.
Configure Management Default Gateway Address
The configure management default gateway command specifies the IP address of the next hop router for the management traffic.
Table 4-1. CLI Commands
Command Function
clear Clear the system log.
configure Enter Configuration mode.
copy Copy from one file to another.
date Set the time zone and date format.
end If user is in Administrator mode, shifts to User mode; if user is in
User mode, positions interface at top of menu tree.
exit Terminate current session.
firmware Download or apply new firmware.
paging Enable or disable paging (more prompt) for this session.
privilege Enable administrator mode.
restart Restart a unit.
show Display configuration, statistics, and status.
technical-support Display information for contacting technical support.
test Test the system.
configure management default-gateway {ip_address}
Minimum Access Level: Administrator
ip_address – Specifies the IP address of the default gateway for the management ports.
Example:
PDYN# configure management default-gateway 137.90.127.1
Page 39
4. Configuration
2600-A2-GN20-50 April 2005
4-3
Configure Management Inband Address
The configure management inband address command specifies the IP address of the unit.
Configure Management Out-of-Band Address
The configure management out-of-band address command specifies the IP address of the unit that will accept management traffic on the out-of-band management port.
configure management inband address {ip_address} { subnet_mask}
Minimum Access Level: Administrator
ip_address – Specifies the management IP address. Default is 0.0.0.0 (disabled). Do
not configure inband and out-of-band management on the same subnet.
subnet_mask – Specifies the subnet mask to be applied to the IP address. The default mask is 255.255.255.0.
Example:
PDYN# configure management inband address 137.90.127.3
255.255.255.0
configure management out-of-band address {bootp | {{ip_address} { subnet_mask} }
Minimum Access Level: Administrator
bootp – Specifies that a BOOTP server will determine the management IP address.
ip_address – Specifies the management IP address. The default address is
10.10.10.10. Do not configure inband and out-of-band management on the same subnet.
subnet_mask – Specifies the subnet mask to be applied to the IP address. The default mask is 255.255.255.0.
Example:
PDYN# configure management out-of-band address bootp
PDYN# configure management out-of-band address 137.90.127.3
255.255.255.0
Page 40
4. Configuration
4-4 April 2005 2600-A2-GN20-50
BitStorm 2600 Startup Procedure
You can initialize your BitStorm 2600 via a PC or terminal connected to the unit’s CONSOLE port. Then, using a series of CLI commands, GrandVIEW EMS or another Element Management System, or the web interface, you can configure the unit according to your requirements.
Login
Procedure
To log in to the BitStorm 2600:
1. Connect a PC or terminal to the CONSOLE port. (See Console Port in
Chapter 2, Cabling.)
2. At the login> prompt, type admin and press Enter.
3. At the password> prompt, press Enter. The default login password is blank.
4. At the PDYN> prompt, type privilege and press Enter.
5. At the password# prompt, press Enter. The default privileged password is blank.
You are now logged on and in privileged mode, which allows you to configure the unit.
Management Modes
The startup procedure for the BitStorm 2600 system differs depending on the type of management used:
Inband Management – Operates over the uplink.
Out-of-Band Management – Operates over Port 1.
Page 41
4. Configuration
2600-A2-GN20-50 April 2005
4-5
Startup Procedure for Inband Management
With inband management, the BitStorm 2600 is managed using the uplink port.
Procedure
To start up the BitStorm 2600 using inband management:
1. Specify the uplink port using the configure uplink command. It must be either eth2 (Port 2) or eth3 (Port 3). For example:
PDYN# configure uplink eth3
2. Assign an IP address, netmask, and next-hop router using the configure management command. For example:
PDYN# configure management inband address 137.90.127.3
255.255.255.0
PDYN# configure management default-gateway
137.90.127.1
Do not configure inband and out-of-band management on the same subnet.
Changing the VLAN for Inband Management
By default, all ports are untagged members of VLAN 1. This can be modified using the CLI.
Procedure
To change the VLAN for inband management:
1. Display the current VLAN configuration:
PDYN# sho vlan configuration all
VLAN 1 Name default Tagged Members UnTagged Members 1-24, mgmt_i, eth2, eth3 ProxyARP disabled Secure Mode disabled Proxy Arp NHR 0.0.0.0
VLAN 4080 Name OutOfBand VLAN Tagged Members UnTagged Members mgmt_o, eth1 ProxyARP disabled Secure Mode disabled Proxy Arp NHR 0.0.0.0
Page 42
4. Configuration
4-6 April 2005 2600-A2-GN20-50
2. Delete untagged ports from VLAN 1:
PDYN#!configure vlan modify 1 ports untagged delete Vlan 1 default, 'untagged' ports 'delete', modified successfully.
3. Create a new VLAN (VLAN 2 in this example):
PDYN#configure vlan create 2 Vlan 2 Created successfully.
4. Add untagged ports to VLAN 2:
PDYN#!configure vlan modify 2 ports untagged mgmt_i,eth3
Vlan 2 , 'untagged' ports 'mgmt_i,eth3', modified successfully.
5. Display the configuration of VLAN 2:
PDYN#!sho vlan configuration 2
VLAN 2 Name Tagged Members UnTagged Members mgmt_i, eth3 ProxyARP enabled Secure Mode enabled Proxy Arp NHR 0.0.0.0
Alternatively, the uplink may be tagged and DSL ports untagged.
Procedure
1. Add a tagged port to VLAN 2:
PDYN#!configure vlan modify 2 ports tagged eth3 Vlan 2 , 'tagged' ports 'eth3', modified successfully.
2. Add untagged ports to VLAN 2:
PDYN#!configure vlan modify 2 ports untagged mgmt_i Vlan 2 , 'untagged' ports 'mgmt_i', modified successfully.
3. Display the configuration of VLAN 2:
PDYN#!sho vlan configuration 2
VLAN 2 Name Tagged Members eth3 UnTagged Members mgmt_i ProxyARP enabled Secure Mode enabled Proxy Arp NHR 0.0.0.0
Page 43
4. Configuration
2600-A2-GN20-50 April 2005
4-7
Startup Procedure for Out-of-Band Management
In out-of-band management, you manage the unit through Port 1.
Procedure
To start up the BitStorm 2600 using out-of-band management:
1. Assign an IP address, netmask, and next-hop router using the configure management command. For example:
PDYN# configure management out-of-band address
137.90.80.3 255.255.255.0
PDYN# configure management default-gateway 137.90.80.1
You can now access the web interface by typing into the Location field of your web browser the IP address assigned to the Port 1. See Using the Web
Interface on page 4-8.
Do not configure inband and out-of-band management on the same subnet.
2. Configure routers as necessary to route data from the NOC to the BitStorm 2600.
Page 44
4. Configuration
4-8 April 2005 2600-A2-GN20-50
Using the Web Interface
To access the web interface:
Procedure
1. Open your web browser. (Internet Explorer Version 6 or above is recommended.)
2. Type http:// and the IP address of the BitStorm 2600 into the Address field of your browser window. For example:
3. A login window appears. Enter the default User ID (admin) and leave Password blank. Click on OK. The web interface screen appears.
4. Click on the menu tab appropriate to what you would like to do:
— Configuration – To configure the system and interfaces
— Status – To display statistics, status, and contents of memory
— System – To display system information, download firmware, back up
configurations, and modify users
— Diagnostics – To start and stop tests
Page 45
4. Configuration
2600-A2-GN20-50 April 2005
4-9
System / Users
For security reasons, it is a good idea to change the default password the first time you use the system.
Procedure
To change the default password for user admin:
1. Click on the System menu tab, then click on Users. The folllowing screen appears.
2. In the Configured Users box, select admin by clicking in the circle next to it.
3. Click on Modify Selected. The System / Users / admin screen appears.
4. Type in a new Login Password and a new Privilege Password, then click on Apply. Keep a record of the new password.
Page 46
4. Configuration
4-10 April 2005 2600-A2-GN20-50
Configuration / Management / SNMP
SNMP access to the unit is disabled by default. The read-only community string is public, and the read-write string is private. Community strings, network management system addresses, and trap manager addresses can be set using the System/Management/SNMP screen.
Procedure
To set SNMP parameters:
1. Click on the Configuration menu tab, then click on SNMP. The System/Management/SNMP screen appears.
2. Enter new SNMP parameters as desired. Click on Apply.
Page 47
2600-A2-GN20-50 April 2005 A-1
A
Connectors and Pin Assignments
Overview
The following sections provide pin assignments for:
DSL Ports and POTS Splitter Connectors on page A-2
Port 1 and Port 2 10/100BaseT Connectors on page A-3
Port 3 1000BaseT Connector on page A-3
Port 3 GigE SFP Connector on page A-4
E1 and T1 Uplink Connectors on page A-5
Console Port Connector on page A-5
ALARM Connector on page A-6
Figure A-1. BitStorm 2600 IP Front Panel
DSL PORTS 1-24
POTS 1-24
03-17455
2600
PORT1-10/100BT
CONSOLE
PORT2-10/100BT PORT3
LINK
ACT
GigE
STATUS
ALARM
TEST
ALARM
1
2
23
1000BT
24
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Page 48
A. Connectors and Pin Assignments
A-2 April 2005 2600-A2-GN20-50
DSL Ports and POTS Splitter Connectors
The 50-pin RJ21X Telco connector labeled DSL Ports 1–24 provides the 2-wire loop interface from each DSL port to the MDF for CO applications, or the in-building wiring for customer premises applications. (The Canadian designation for this connector is CA21A.) The 50-pin RJ21X (CA21A) Telco connector labeled POTS 1–24 (if installed) provides the 2-wire loop interface with the internal POTS splitters.
Ta bl e A- 1 lists the pin assignments for these interfaces. Note that Pins 25 and 50
are not used.
Table A-1. DSL Connector Pinouts
DSL Port
Connector Pins (Ring, Tip)
11, 26
22, 27
33, 28
44, 29
55, 30
66, 31
77, 32
88, 33
99, 34
10 10, 35
11 11, 36
12 12, 37
13 13, 38
14 14, 39
15 15, 40
16 16, 41
17 17, 42
18 18, 43
19 19, 44
20 20, 45
21 21, 46
22 22, 47
23 23, 48
24 24, 49
25
02-17151
1
50
26
Page 49
A. Connectors and Pin Assignments
2600-A2-GN20-50 April 2005
A-3
Port 1 and Port 2 10/100BaseT Connectors
Port 1 and Port 2 are 8-pin unkeyed modular jacks for a 10/100Base interface.
Port 3 1000BaseT Connector
Port 3’s 1000BaseT interface is an 8-pin unkeyed modular jack.
Table A-2. Port 1 and Port 2 Pinouts
Signal Pin
Transmitted Data + 1
Transmitted Data – 2
Received Data + 3
Unused 4
Unused 5
Received Data – 6
Unused 7
Unused 8
97-15449
Pin 1
Pin 8
Table A-3. Port 3 1000BaseT Connector
Signal Pin
Tip 1 1
Ring 1 2
Tip 2 3
Ring 3 4
Tip 3 5
Ring 2 6
Tip 4 7
Ring 4 8
97-15449
Pin 1
Pin 8
Page 50
A. Connectors and Pin Assignments
A-4 April 2005 2600-A2-GN20-50
Port 3 GigE SFP Connector
Port 3’s GigE interface is a standard SFP socket.
Table A-4. Port 3 GigE Connector
Signal Pin
VeeT 1
TXFault 2
TXDisable 3
MOD-DEF(2) – I2C_DATA 4
MOD-DEF(1) – I2C_CLK 5
MOD-DEF(0) – SFP_PRESENT_L 6
Rate Select 7
LOS 8
VeeR 9
VeeR 10
VeeR 11
RD- 12
RD+ 13
VeeR 14
VccR 15
VccT 16
VeeT 17
TD+ 18
TD- 19
VeeT 20
Page 51
A. Connectors and Pin Assignments
2600-A2-GN20-50 April 2005
A-5
E1 and T1 Uplink Connectors
The E1 and T1 connectors on T1/E1 MLPPP models are single, RJ48C, unkeyed, shielded, 8-pin modular jacks. The shield is connected to ground via the module.
Console Port Connector
The CONSOLE port connector is a DB9 socket connector that supports an EIA-232-E circuit as shown in Ta bl e A- 6 .
Table A-5. E1 Uplink Connectors
Signal Direction Pin
Receive Ring In 1
Receive Tip In 2
NC 3
Transmit Ring Out 4
Transmit Tip Out 5
NC In 6
NC 7
NC 8
Table A-6. Console Port Connector
RS-232 Signal Direction Pin
Data Carrier Detect Out 1
Receive Data Out 2
Send Data In 3
Data Terminal Ready In 4
Ground 5
Data Set Ready Out 6
Request to Send In 7
Clear to Send In 8
Ring Indicator 9
Page 52
A. Connectors and Pin Assignments
A-6 April 2005 2600-A2-GN20-50
ALARM Connector
The alarm relay reports major alarms through the ALARM connector.
The alarm contacts are closed during normal operation. They open in response to loss of power, hardware failure, or other alarm conditions. The maximum rated load for the alarm relays is:
30 VDC: 1.0 Amp
60 VDC: 0.6 Amp
60 VAC: 0.6 Amp
Table A-7. ALARM Connections
Signal Direction Contact
Major Alarm Out 1
Common Out 2
Minor Alarm Out 3
Alarm Sense + In 4
Alarm Sense – In 5
03-17453
5 4 3 2 1
ALARM
Page 53
2600-A2-GN20-50 April 2005 B-1
B
Equipment List
All BitStorm 2600 models include the BitStorm 2600, 19- and 23-inch mounting brackets
and hardware, and an Installation Guide.
Table B-1. BitStorm 2600 Model List (1 of 2)
Model Number
DSL Ports DSL Type Splitters
Power Cord Compatibility Other Features
2611-A1-420 24 ReachDSL None North America
2611-A1-424 24 ReachDSL None UK
2611-A1-425 24 ReachDSL None Europe
2611-A1-430 24 ReachDSL 900 Ohm North America
2611-A1-434 24 ReachDSL 600 Ohm UK
2611-A1-435 24 ReachDSL 600 Ohm Europe
2611-A1-436 24 ReachDSL 600 Ohm India
2614-A1-420 24 ReachDSL None North America T1 MLPPP (8 ports)
2614-A1-422 24 ReachDSL None North America E1 MLPPP (8 ports)
2621-A2-420 24 ADSL2+ None North America
2621-A2-424 24 ADSL2+ None UK
2621-A2-425 24 ADSL2+ None Europe
2621-A2-430 24 ADSL2+ 900 Ohm North America
2621-A2-434 24 ADSL2+ 600 Ohm UK
2621-A2-435 24 ADSL2+ 600 Ohm Europe
2621-A2-436 24 ADSL2+ 600 Ohm India
2624-A1-420 24 ADSL2+ None North America T1 MLPPP (8 ports)
2624-A1-422 24 ADSL2+ None North America E1 MLPPP (8 ports)
2631-A2-425 24 ADSL2+ None Europe Annex B
2671-A1-420 24 SHDSL None North America
2674-A1-420 24 SHDSL None North America T1 MLPPP (8 ports)
Page 54
B. Equipment List
B-2 April 2005 2600-A2-GN20-50
2674-A1-422 24 SHDSL None North America E1 MLPPP (8 ports)
Table B-2. BitStorm 2600 Related Equipment List
Model Number Description
2600-A2-GB21 BitStorm 2600 and GranDSLAM 4200 IP Command Line Interface
Reference (paper copy)
2600-A2-GB22 BitStorm 2600 and GranDSLAM 4200 IP SNMP Reference (paper
copy)
4200-F1-001 Mounting Brackets for ETSI 21-inch (535 mm) Rack
4200-F3-000 Single-Mode 1000BaseLX SFP Transceiver
(10 km, 1310 nm FP-LD)
4200-F3-001 Single-Mode 1000BaseLX SFP Transceiver
(40 km, 1310 nm DFB-LD)
4200-F3-002 Single-Mode 1000BaseZX SFP Transceiver
(80 km, 1550 nm DFB-LD)
4200-F3-003 Multimode 1000BaseSX SFP Transceiver
(0.55 km, 850 nm VCSEL)
5011-A1-000 1-Slot POTS Splitter Chassis
5016-A1-000 6-Slot POTS Splitter Chassis
6051-B1-001 BitStorm 6051 Universal Line Sharing POTS Splitter
8400-F1-001 LC to SC Multimode Conversion Cable
8400-F1-002 LC to SC Single-Mode Conversion Cable
Table B-1. BitStorm 2600 Model List (2 of 2)
Model Number
DSL Ports DSL Type Splitters
Power Cord Compatibility Other Features
Page 55
2600-A2-GN20-50 April 2005 C-1
C
Technical Specifications
Technical specifications are subject to change without notice.
Table C-1. BitStorm 2600 Technical Specifications (1 of 2)
Specifications Criteria
Alarm Contacts Maximum Rated Load
30 VDC: 1.0 Amp
60 VDC: 0.6 Amp
60 VAC: 0.6 Amp
Cooling and Air Handling
Each BitStorm 2600 is independently cooled with integral fans and does not rely on vertical air flow.
DSL Compatibility
Models 2611 and 2614:
ReachDSL 2.2
Models 2621 and 2624:
G.dmt (G.992.1)
G.lite (G.992.2)
ANSI T1.413-1998
ADSL2 (G.992.3)
ADSL2+ (G.992.5)
Model 2631:
G.dmt (G.992.1) Annex B
ADSL2 (G.992.3) Annex B
ADSL2+ (G.992.5) Annex B
Model 2671:
G.SHDSL (G.991.2)
Electromagnetic Compatibility (EMC)
Meets the following standards:
EN 300 386-2
EN 55024
EN 55022, Class A
FCC Part 15, Class A
VCCI, Class A
Page 56
C. Technical Specifications
C-2 April 2005 2600-A2-GN20-50
Interfaces DSL PORTS: 50-pin RJ21X Telco-type connector
POTS: 50-pin RJ21X Telco-type connector
CONSOLE: DB9 (EIA-232-E)
Port 1 and Port 2: 8-pin modular jack (10/100BaseT)
Port 3 copper interface: 8-pin modular jack (1000BaseT)
Port 3 fiber interface: SFP socket
T1/E1 MLPPP interface: eight RJ48C modular jacks
Operating Environment
Ambient Temperature: 0° to 50° C (32° to 122° F) Relative Humidity: 5% to 95% noncondensing Storage Temperature: – 40° to 85° C (– 40° to 185° F) Shock and vibration tolerance sufficient to withstand normal shipping
Physical Dimensions
Height: 1.75 (44.5 mm, or 1U as defined in EIA-310-C) without feet Width: 17.2 (437 mm) without mounting brackets Depth: 16.0 (406 mm) with cables
Power 90–265 VAC, 47–63 Hz
Power Consumption
Model 2611: 45 Watts Maximum
Model 2614: 43 Watts maximum
Model 2621: 57 Watts Maximum
Model 2624: 55 Watts Maximum
Model 2631: 57 Watts Maximum
Model 2671: 46 Watts Maximum
Model 2674: 44 Watts Maximum
Weight 2611 without splitters: 15.1 lb (6.8 kg)
2611 with splitters: 17.0 lb (7.7 kg)
2614: 13.1 lb (5.9 kg)
2621 without splitters: 14.7 lb (6.7 kg)
2621 with splitters: 16.3 lb (7.4 kg)
2624: 12.2 lb (5.5 kg)
2631 without splitters: 14.7 lb (6.7 kg)
2631 with splitters: 16.3 lb (7.4 kg)
2671: 15.5 lb (7.0 kg)
2674: 13.1 lb (5.9 kg)
Table C-1. BitStorm 2600 Technical Specifications (2 of 2)
Specifications Criteria
Page 57
2600-A2-GN20-50 April 2005 IN-1
Index
Numerics
10/100BaseT pinouts, A-3 1000BaseT pinouts, A-3
A
AC power, 2-12 Activity LEDs, 3-2 administrator, login, 4-4 Alarm
connector pinouts, A-6 LED, 3-2 port cabling, 2-10 port connectors, A-6
port description, 1-3 audience for this document, iii autosensing, 2-4, 2-7
B
BitStorm 2600
description, 1-1 brackets
installation for rack mount, 1-6
C
cables, A-1
DSL ports, A-2
MGMT port, A-3
required, 1-3 cabling, 2-1
ALARM port, 2-10
console port, 2-8
DSL ports, 2-2
GigE uplink, 2-3
ground, 2-11
management port, 2-7
Port 1, 2-7
Port 2, 2-4
Port 3, 2-3
POTS ports, 2-2
power, 2-12
T1/E1 MLPPP, 2-5
uplink, 2-4–2-5 CO alarm system, 2-10 CO grounding screw, 2-11 Command Line Interface (CLI), 4-2
commands, 4-2 community strings, 4-10 configuration, 4-1
CLI commands, 4-2 mounting brackets, 1-6
configuring
inband management, 4-5 out-of-band management, 4-7 SNMP parameters, 4-10
connectors, A-1
ALARM, A-6 CONSOLE port, A-3 DSL ports, A-2 front panel, A-1 Management port, A-3 Port 3, A-4 POTS splitter, A-2 T1/E1 uplink, A-5
CONSOLE port, 2-8
cabling and settings, 2-8 connecting modem, 2-9 connector, A-3 description, 1-3 pin assignments, A-3
pinouts, A-5 contents of shipping carton, 1-4 cooling and air handling, C-1
D
DB9
cabling, 2-8
pinouts, A-5 default gateway, 4-2 default password, 4-4
changing, 4-9 desktop installation, 1-12 dimensions, C-2 document purpose, iii documents
online, iii
ordering, iv
related, iv DSL ports
cabling, 2-2
description, 1-3
LEDs, 3-2
pin assignments, A-2
Page 58
Index
IN-2 April 2005 2600-A2-GN20-50
E
E1 uplink
cabling, 2-5
pin assignments, A-5 earth ground, 2-11 Electromagnetic Compatibility (EMC), C-1 EMS, 4-4 Enter key, 4-2 environment, C-2 equipment list
hardware provided, 1-5
package contents, 1-4
part numbers, B-1 ESD precautions, 1-4 Ethernet
LEDs, 3-2
pinouts, A-3
F
fasteners provided, 1-5 feature numbers, B-1 feet, 1-12 front panel, 3-1, A-1
illustration, A-1
LEDs, 3-1
G
GigE uplink, 2-3 glossary URL, iii grounding screw, 2-11
H
hardware kit contents, 1-5
I
inband management
configuring, 4-5
described, 4-4
VLAN, 4-5 initialization procedures, 4-4 installation, 1-1
options, 1-2
installing
feet for shelf installation, 1-12 in rack, 1-8 mounting brackets for rack mount, 1-6 mounting brackets for wall mount, 1-10 on shelf or desktop, 1-12 screws for wall mount, 1-11 self-retaining nuts, 1-8 unit into rack, 1-8 unit on wall, 1-10
interfaces, C-2
J
jack screw, 2-2
L
LEDs, 3-1 License Agreement, B Link LEDs, 3-2 login, 4-4 lug for grounding, 2-11
M
management modes, 4-4 Management port, 2-7
cabling, 2-7 connector, A-3 description, 1-3
pin assignments, A-3 menu tabs, 4-8 MLPPP, 2-5 modem, connecting to Console port, 2-9 mounting brackets, description, 1-6 mounting configurations, 1-2, 1-6
N
network management systems, 4-10 NMS, 4-10
O
operating environment, C-2 optional mounting brackets, 1-6 order numbers, B-1 out-of-band management
configuring, 4-7
described, 4-4
Page 59
Index
2600-A2-GN20-50 April 2005
IN-3
overview
cabling, 2-1 configuration, 4-1 management modes, 4-4 of BitStorm 2600, 1-1 of book, iii
P
package contents, 1-4 part numbers, B-1 password, 4-4
changing, 4-9
default, 4-4 PC cabling and settings, 2-8 physical dimensions, C-2 pin assgnments
E1, A-5 pin assignments, A-1
Alarm, A-6
CONSOLE port, A-3
Console port, A-5
Management port, A-3
Port 3, A-3
Ports 1 and 2, A-3
RJ21X connectors, A-2
SFP socket, A-4
T1, A-5
Telco connectors, A-2 Port 1
cabling, 2-7
description, 1-3
pinouts, A-3 Port 2
cabling, 2-4
description, 1-3
pinouts, A-3 Port 3
cabling, 2-3
description, 1-3
pinouts, A-3–A-4
SFP socket pin assignments, A-4 POTS connector pin assignments, A-2 POTS splitter
cabling, 2-3
pin assignments, A-2
port description, 1-3 power, C-2
connecting to, 2-12
consumption, C-2
requirements, 2-12, C-2 PPP, 2-5 preinstallation, 1-2 product-related documents, iv
purpose of this document, iii
R
rack installation, 1-8
bracket installation, 1-6 example, 1-9
procedure, 1-8 related documents, iv Return key, 4-2 RJ21X connectors, A-2 RJ45 pinouts, A-3
S
screws provided, 1-5 SFP socket
cabling, 2-3
pinouts, A-4 shelf installation, 1-12 shipping carton, 1-4 site preparation, 1-2 site requirements, 1-2, C-2 SNMP, configuring parameters, 4-10 Software and Firmware License Agreement, B specifications
product, C-1 stacking, 1-2 startup procedures, 4-4 Status LED, 3-2 synopsis of chapters, iii
T
T1 uplink
cabling, 2-5
pin assignments, A-5 technical specifications, C-1 Telco connectors
fastening, 2-2
pinouts, A-2 terminal cabling and settings, 2-8 Test LED, 3-2 trap managers, 4-10 troubleshooting, LEDs, 3-1 turn-up procedures, 4-4 typographic conventions, 4-2
U
unpacking, 1-4 uplink
cabling, 2-4–2-5
GigE, cabling, 2-3
Port 2, 2-4 Uplink Ports LEDs, 3-1–3-2
Page 60
Index
IN-4 April 2005 2600-A2-GN20-50
V
VLAN
for inband management, 4-5
VT100 cabling and settings, 2-8
W
wall mount
bracket installation, 1-10
screw positions, 1-11 web interface
password, 4-9
starting, 4-8
using, 4-8 weight, C-2
Loading...