Paradyne ACCULINK 3161 CSU, ACCULINK 3161 DSU, ACCULINK 3161 Quick Reference Manual

ACCULINK 3161 DSU/CSU
QUICK REFERENCE
Document No. 3161-A2-GL11-40
Copyright 1998 Paradyne Corporation. All rights reserved. Printed in U.S.A.
Notice
This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Avenue North, P.O. Box 2826, Largo, Florida 33779-2826.
Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes.
Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual.
Warranty, Sales, and Service Information
Contact your sales or service representative directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, or training, use one of the following methods:
Via the Internet: Visit the Paradyne World Wide Web site at
http://www.paradyne.com
Via Telephone: Call our automated call system to receive current information via
fax or to speak with a company representative.
— Within the U.S.A., call 1-800-870-2221 — International, call 727-530-2340
T rademarks
All products and services mentioned herein are the trademarks, service marks, registered trademarks or registered service marks of their respective owners.
TM
1
ACCULINK 3161 DSU/CSU
Quick Reference
Document Number 3161-A2-GL11-40 February 1998
Quick Start Procedure
The following procedure is for experienced DSU/CSU users who are familiar with the 3161 DSU/CSU installation process and have no special requirements for their application. See the
ACCULINK 316x Data Service Unit/Channel Service Unit
Operator’s Guide
(3160-A2-GB21) for more information. A copy is included with the
Auxiliary Backplane.
1. Install the Auxiliary Backplane onto the 3000 Series Carrier. See the
ACCULINK
3151 CSU and 3161 DSU/CSU General Information Guide
(3100-A2-GK40) for
installation procedures.
2. Attach the DTE cable (DB15) and/or port cables (DB25) to the appropriate connectors on the Auxiliary Backplane. See the
COMSPHERE 3000 Series Carrier
Installation Manual
(3000-A2-GA31) for detailed cable and connector information.
Connect the other end of the DTE cable to the customer premises equipment.
2
3. Attach the network cable to the Auxiliary Backplane using either a 50-pin cable or the T1 Network Interface Adapter. Connect the other end of the network cable to the connection provided by the telephone company.
496-14386-0
3
Auxiliary
Backplane
over Slots 9–16
COMSPHERE
3000 Series
Carrier (Rear)
T1 Network
Cable
Cable
Retainer
4. Turn on the power to the 3000 Series Carrier.
3
5. Insert the DSU/CSU circuit card into the appropriate slot in the carrier. The power-up self-test begins.
495-1479
7
6. If you intend to use front panel emulation, connect the cable from the PC to Port 2 on the Auxiliary Backplane using the COM port adapter and COM-port-to-PC cable.
7. If you do not intend to use the DTE Drop/Insert T1 port, disable it using the configuration procedures in Chapter 3,
Operation
, and Appendix C,
Configuration
Options
, of the
ACCULINK 316x Data Service Unit/Channel Service Unit
Operator’s Guide
(3160-A2-GB21). (The default setting for this port is Enabled.)
8. The Factory 1 configuration for ESF framing format and B8ZS line coding format is the default configuration and is appropriate for most networks. If this configuration does not work for you, try the Factory 2 configuration for D4 framing format and AMI line coding format. To further customize configuration options, refer to
Changing Configuration Options
in Chapter 3,
Operation
, and Appendix C,
Configuration Options
, in the
ACCULINK 316x Data Service Unit/Channel Service
Unit Operator’s Guide
.
9. During the power-up self-test, the FAIL LED flashes, then all LEDs blink twice. When the test is complete, verify that the DSU/CSU is functional by observing that the OK, NETWORK SIG, and DTE SIG LEDs are lit.
10. Configure the ports and channels you intend to use and assign channels to the network interface.
4
Configuration Options
Configuration options are accessed from the Cnfig branch of the front panel menu.
DSU ESF
Stat
97-15577
DevHS
STest Perf TSt a t LED ID
T1 PrtnPrtnUserTelco
Cur
24Tot
Intvl
FarNear
Cur
8Tot
Intvl
Test
Rlpbk Lpbk Ptrns Lamp
QRSS 511
Abort Mon
LLBUP
LLBDN
54UP
54DN
FT1UP
FT1DN
PLB DLB RLBLLBAbort DCLB DTLB
QRSS 1in8 511
Send
Cnfig
EQPT NET
Ctrl
Rel ClrReg
Reset
CID
PasswdLED
ACO
DL
Mon
Call
DiscDial ChDir
1 . . 5,A
(Directory)
1 . . 5,A
(Directory)
DTE Prt1 Prt2
User Prt1 Prt2
FarNear
Load Edit Area From:
Choose Function:
Activ Cust1 Cust2 Fact1 Fac t2
User AlarmNETDTE Port Chan Gen Mgmt
Gen Trap
DTE Pr t1
Prt2
ClearDsply
Copy Prt1 Prt2
Port Select :
All Prt1 Prt2
Save
Cust1Activ Cust2
Edit
Loading...