Paradyne 4300 User Manual

4300 Remote Broadband Access Concentrator
Installation Instructions
Document Number 4300-A2-GZ40-00
July 2004
Contents
CONTENTS.................................................................................................................................................................................. 1
USING THIS INSTALLATION GUIDE ................................................................................................................................... 2
PRODUCT DOCUMENTATION ONLINE.............................................................................................................................. 2
INSPECTING SHIPMENT......................................................................................................................................................... 3
WARRANTY, SALES, SERVICE, AND TRAINING INFORMATION ............................................................................... 3
PRODUCT OVERVIEW............................................................................................................................................................. 3
INSTALLATION PROCEDURE ............................................................................................................................................... 9
CABINET GROUNDING INFORMATION........................................................................................................................... 14
PROTECTION/CROSS CONNECTS...................................................................................................................................... 16
PROTECTION/CROSS CONNECT WIRING TABLES ...................................................................................................... 17
FAN/FILTER REPLACEMENT.............................................................................................................................................. 19
EXTERNAL WIRING............................................................................................................................................................... 20
LINE POWER ............................................................................................................................................................................ 20
SCHEMATIC WIRING DIAGRAMS ..................................................................................................................................... 20
4300-A2-GZ40-00 July 2004 1
4300 Remote Broadband Access Concentrator Installation Instructions
Using This Installation Guide
This publication provides a description of the 4300 Remote Broadband Access Concentrator (BAC). Typical applications, mechanical descriptions, installation instructions, safety guidelines, grounding instructions, and wiring diagrams are included.
Two types of messages appear throughout this manual, identified by the following icons:
Note - indicates special conditions.
Caution - indicates possibility of personal injury or equipment damage.

Product Documentation Online

Complete documentation for this product is available at www.paradyne.com. Select Support Technical Manuals.
Select the following documents:
2600-A2-GB21
GranDSLAM 4200 IP DSLAM Command Line Interface Reference
2600-A2-GB22
GranDSLAM 4200 IP DSLAM SNMP Reference
2600-A2-GT20
GranDSLAM 4200 IP DSLAM Training Guide
4200-A2-GB20
GranDSLAM 4200 ATM DSLAM User's Guide
4200-A2-GN20
GranDSLAM 4200 ATM DSLAM Installation Guide
4200-A2-GN21
GranDSLAM 4200 IP DSLAM Installation Guide
4300-A2-GZ41-00
Field Upgrade Kit for the 4300 Remote BAC, Feature Number 4300-F1-100, Installation Instructions
4300-A2-GZ42-00
Pole Mounting Kit for the 4300 Remote BAC, Feature Number 4300-F1-400, Installation Instructions
4300-A2-GZ43-00
Wall Mounting Kit for the 4300 Remote BAC, Feature Number 4300-F1-401, Installation Instructions
4300-A2-GZ44-00
Fan Replacement Kit for the 4300 Remote BAC, Feature Number 4300-F1-500, Installation Instructions
4300-A2-GZ45-00
Filter Replacement Kit for the 4300 Remote BAC, Feature Number 4300-F1-501, Installation Instructions
To order a paper copy of a Paradyne document, or to speak with a sales representative, please call 727-530-2000.
2 July 2004 4300-A2-GZ40-00
4300 Remote Broadband Access Concentrator Installation Instructions

Inspecting Shipment

On receipt of the equipment, inspect the shipping container(s) and note any signs of damage. Then unpack the container(s) and carefully inspect for damage to the contents. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and your sales representative.
Warranty, Sales, Service, and Training Information
Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:
Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty
at www.paradyne.com/warranty.)
Telephone: Call our automated system to receive current information by fax or to speak with a company
representative.
– Within the U.S.A., call 1-800-870-2221
– Outside the U.S.A., call 1-727-530-2340
Trademarks
GranDSLAM is a registered trademark of Paradyne Corporation. All other products and services mentioned herein are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners.

Product Overview

The 4300 Remote BAC is a pole-mounted or wall-mounted outdoor telecommunications equipment cabinet. The cabinet has overall dimensions of 26 inches high x 19 inches deep x 22 inches wide. See the figures on the following pages for details.
The cabinet is constructed of aluminum with a powder coat painted finish for reduced weight and superior corrosion resistance. The front door is equipped with a quarter turn padlockable door latch. The top of the cabinet has a double wall construction to reduce the effects of solar radiation and for structural integrity.
Cooling is provided by a –48 VDC fan ventilation system. The fan is mounted to the roof of the cabinet behind the equipment. The fan pulls air through the front door of the cabinet and exhausts the air through the roof overhang and the louvers in the sides of the roof.
The left front of the equipment-mounting bay has 6U (10.5 inches) of 19" rack space provided for mounting up to three GranDSLAM 4200 assemblies (1U each) and a rectifier or a DC-DC converter (2U each). An additional 1U is provided for future expansion. Two swing-out 19” racks are provided on the right side of the equipment bay for mounting up to four 50 pair protection/cross connect assemblies (200 pair capacity). Each protection/cross connect swing-out rack has 4U of 19” rack space (8U total).
Cable entry and exit from the cabinet passes through two sealing boots located in the bottom rear of the equipment bay. The master grounding bus bar is located on the rear wall of the equipment bay on the left side. AC and DC power centers are mounted to the rear wall on the right side.
4300-A2-GZ40-00 July 2004 3
4300 Remote Broadband Access Concentrator Installation Instructions
Cabinet lifting eyelets
Rectifier or DC-DC Converter
GranDSLAM 4200 DSLAMs
Protection/Cross Connect Panels
Swing out racks for Protection/Cross
Figure A - Front view of cabinet with door open
4 July 2004 4300-A2-GZ40-00
Cable Management Brackets
4300 Remote Broadband Access Concentrator Installation Instructions
Ground Bus Bar
AC Input Panel for Model 2
DC Input Panel for Model 3
Air Filters
Cable Entry Ports
DC Distribution Box
Figure B - Front view of cabinet without equipment

CABINET CONFIGURATIONS

Three basic cabinet configurations are offered as explained below. Expansion kits are provided to increase the capacity of each configuration to up to three GranDSLAM 4200 DSLAMs. Kits are also provided for fan and filter replacement and for pole or wall mounting brackets.
Model numbers are of the form 43WX-P1-Y0Z, where:
W is the DSL type (1 for ReachDSL, 2 for ADSL, 3 for ADSL Annex B, 7 for SHDSL)
X is the uplink type (1 for T1 ATM, 2 for E1 ATM, 3 for 8-port T1/E1 IMA, 9 for 10/100/1000BaseT/GigE fiber)
Y is the power type (1 for externally-fed –48/–60 VDC, 2 for AC, 3 for line power)
Z is the splitter option (0 for 900 ohm, 1 for 600 ohm)
The three basic cabinet configurations are:
Model 1 (Feature Number 43xx-P1-10x) - Cabinet to be used at existing remote terminal sites, where the RT can supply –48 VDC power. This model will be wired for one GranDSLAM assembly.
Model 2 (Feature Number 43xx-P1-20x) – Cabinet to be used where AC power is available. This model will be wired for one GranDSLAM assembly and will include an AC load center and a –48 VDC rectifier.
Model 3 (Feature Number 43xx-P1-30x) – Cabinet to be used where AC power is not available. Power to the cabinet will be provided by up to 25 common pairs. The tips and rings of the pairs are bussed together and fed to a DC-DC converter, which provides the –48 VDC power to the GranDSLAM assemblies. The input voltage to the DC-DC converter is 90 to 400 VDC. This model will be wired for one GranDSLAM assembly.
4300-A2-GZ40-00 July 2004 5
4300 Remote Broadband Access Concentrator Installation Instructions

EXPANSION, MOUNTING AND MAINTENANCE KITS

See Table 1 for expansion kit part numbers. The Ordering Procedure section of this document contains instructions for ordering the kits.
Table 1 - Expansion, Mounting and Maintenance Kits
Feature Number Description
4300-F1-100
4300-F1-400
4300-F1-401
4300-F1-500
4300-F1-501
Field upgrade for adding one protected GranDSLAM assembly to Model 1, 2 or
3. Includes one 50 pair protection/100 pair cross connect block and associated cabling.
Pole mounting kit. Includes mounting brackets and hardware for pole mounting the cabinet.
Wall mounting kit. Includes mounting brackets and hardware for wall mounting the cabinet.
Fan field replacement kit. Includes one –48 VDC fan assembly.
Filter field replacement kit. Includes the filters required for one cabinet.
6 July 2004 4300-A2-GZ40-00
4300 Remote Broadband Access Concentrator Installation Instructions

PRODUCT SPECIFICATIONS

Cabinet outer physical dimensions:
Height 26 inches (66 cm) Width 22 inches (56 cm) — does not include heat exchanger Depth 19 inches (48 cm) internal Approx. Weight 60 pounds (27 kg)
Top View
Front View Side View
Figure C – Cabinet overall dimensions
4300-A2-GZ40-00 July 2004 7