Paradyne 3615, 3616 User Manual

Page 1
COMSPHERE
DUALFLOW DATA SERVICE
UNITS
USER’S GUIDE
Document No. 3615-A2-GB20-20
December 1996
Page 2
COMSPHERE DualFlow Data Service Units
User’s Guide 3615-A2-GB20-20
3rd Edition (December 1996)
Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual.
United States
FCC Registration number: AW292J-61661-DD-N PSTN Ringer Equivalence number (REN): DBM option 0.7B
Canada
V.32 Dial Backup Module
Certification number: 230 3684 A DOC Load number: 7
2-Wire Switched 56 DBM
Certification number: 230 5870 A DOC Load number: 0

Warranty, Sales, and Service Information

Contact your sales or service representative directly for any help needed. For additional information concerning warranty , sales, service, repair, installation, documentation, or training, use one of the following methods:
Via the Internet: Visit the Paradyne World W ide Web site at http://www.paradyne.com
Via Telephone: Call our automated call system to receive current information via fax or to speak with a company
representative.
— Within the U.S.A., call 1-800-870-2221 — International, call 727-530-2340
Trademarks
All products and services mentioned herein are the trademarks, service marks, registered trademarks or registered service marks of their respective owners.
Printed on recycled paper
COPYRIGHT 1996 Paradyne Corporation. All rights reserved.
This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Avenue North, P.O. Box 2826, Largo, Florida 33779-2826.
Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes.
A December 1996 3615-A2-GB20-20
Page 3
Important Safety Instructions
1. Read and follow all warning notices and instructions marked on the product or included in the manual.
2. This product is intended to be used with a three-wire grounding type plug – a plug which has a grounding pin. This is a safety feature. Equipment grounding is vital to ensure safe operation. Do not defeat the purpose of the grounding type plug by modifying the plug or using an adaptor.
Prior to installation, use an outlet tester or a voltmeter to check the ac receptacle for the presence of earth ground. If the receptacle is not properly grounded, the installation must not continue until a qualified electrician has corrected the problem.
If a three-wire grounding type power source is not available, consult a qualified electrician to determine another method of grounding the equipment.
3. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.
4. Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord.
Safety Instructions
5. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel.
6. General purpose cables are provided with this product. Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the customer.
7. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance.
8. A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings. If products installed in separate buildings are interconnected, the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the products.
In addition, if the equipment is to be used with telecommunications circuits, take the following precautions:
Never install telephone wiring during a lightning storm. – Never install telephone jacks in wet locations unless the jack is specifically designed
for wet locations.
Never touch uninsulated telephone wires or terminals unless the telephone line has
been disconnected at the network interface.
Use caution when installing or modifying telephone lines. – Avoid using a telephone (other than a cordless type) during an electrical storm.
There may be a remote risk of electric shock from lightning.
Do not use the telephone to report a gas leak in the vicinity of the leak.
B3615-A2-GB20-20 December 1996
Page 4
COMSPHERE DualFlow Data Service Units
Notices


                                
              







 



            

                
                  














Government Requirements
The Federal Communications Commission (FCC) requires that instructions pertaining to connection to the telephone network be included in the installation and operation manual. Specific instructions are listed in this section.
Notice to Users of the Digital Data Service
This equipment complies with Part 68 of the FCC rules. On the bottom of the equipment is a label or silk-screened text that contains, among other information, the FCC registration number and Ringer Equivalence Number (REN) for this equipment. If requested, please provide this information to your telephone company.
The REN is useful to determine the quantity of devices you may connect to your telephone line and still have all of those devices ring when your number is called. In most, but not all areas, the sum of the RENs of all devices should not exceed 5. T may connect to your line, as determined by the REN, you should call your local telephone company to ascertain the maximum REN for your calling area.
If your DSU causes harm to the telephone network, the telephone company may discontinue your service temporarily. If possible, they will notify you in advance. But if advance notice is not practical, you will be notified as soon as possible. Y complaint with the FCC.
o be certain of the number of devices you
ou will be advised of your right to file a
C December 1996 3615-A2-GB20-20
Page 5
Safety Instructions
If your DSU causes harm to the telephone network, the telephone company may discontinue your service temporarily. If possible, they will notify you in advance. But if advance notice is not practical, you will be notified as soon as possible. Y
ou will be advised of your right to file a
complaint with the FCC. Your telephone company may make changes in its facilities, equipment, operations, or procedures
that could affect the proper operation of your equipment. If so, you will be given advance notice so as to give you an opportunity to maintain uninterrupted service.
The DBM cannot be used on public coin-operated telephone service provided by the telephone company. Connection to party-line service is subject to state tariffs. (Contact the state public utility commission, public service commission, or corporation commission for information.)
No repairs may be performed by the user. Should you experience difficulty with this equipment, refer to the Equipment W
arranty and Support
section of Chapter 1.
For Digital Data Service (DDS) installations, inform the local telephone company of the appropriate network channel interface code for the service you desire.
DDS
Interface
Code
04DU5-24 2400 04DU5-48 4800 04DU5-96 9600 04DU5-19 19,200 04DU5-56 56,000 04DU5-64 64,000
Data Rate
(bps)
The DDS Service Order Number is 6.0Y. The jack configurations required are RJ48S for the Model 3615 DSU and RJ48T for the Model 3616. With an RJ48T configuration, you must specify the number of data lines you require. Refer to the T
echnical Specifications
section of Chapter 1 for
V.32 DBM jack information. After the telephone company has installed the requested jack, you can connect the DSU with the
appropriate cable (provided). An FCC-compliant telephone cord and modular plug is provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack that is Part 68 compliant.
D3615-A2-GB20-20 December 1996
Page 6

Table of Contents

Preface
About This Guide vii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to Use This Guide Related Documents Reference Documents
1. About Your DualFlow DSU
Overview 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard Features 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DBM Features
echnical Specifications
T
Equipment Warranty and Support 1-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2. Installing the Model 3615 DualFlow DSU
Overview 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before Y
How to Change Hardware Straps 2-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Where to Place the DSU 2-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the DSU 2-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the Network 2-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the DSU to a Router 2-9. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Addressing the Unit Verifying Operation and T
ou Begin
esting Connections
vii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
viii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
viii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-10. . . . . . . . . . . . . . . . . . . .
3. Installing the Model 3616 DualFlow DSU
Overview 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before Y
How to Change Hardware Straps 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the DSU 3-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the Network 3-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting the DSU to a Router Addressing the Unit Verifying Operation and T
ou Begin
esting Connections
3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-11. . . . . . . . . . . . . . . . . . . .
i3615-A2-GB20-20 December 1996
Page 7
COMSPHERE DualFlow Data Service Units
4. Operating the DualFlow DSU
5. Unit Configuration
Appendices
Overview 4-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DCP and SDCP Operation 4-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Menu Structure 4-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Status Branch Backup Branch
est Branch
T
Configuration Branch 4-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control Branch 4-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Message Branch
Overview 5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the DCP to Set Configuration Options 5-2. . . . . . . . . . . . . . . . . . . .
Configuration Option Tables 5-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Glossary
Index
A.
DSU Menu
B. Configuration Worksheets B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Status Indicators and Control Panel Messages
C.
Pin Assignments
D.
E. Applications Configurations E-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
F. Equipment List F-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-1. . . . . . . . . . . . . . .
D-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ii December 1996 3615-A2-GB20-20
Page 8
Table of Contents

List of Figures

Figure Page
2-1 Model 3615 DSU Hardware Switch Location 2-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2 Model 3615 DSU Electrical Connection 2-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model 3615 DSU Network Connection
2-3
2-4 Model 3615 DSU Dial (PSTN) Network Connection 2-6. . . . . . . . . . . . . . . . . . . . . . . .
Model 3615 DSU Switched 56 kbps Network Connection
2-5
2-6 Model 3615 DSU DDS (LADS) 2-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Router Connection
2-7
2-8 Addressing Example 2-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1 Model 3616 DSU Switch and Jumper Locations 3-3. . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2 COMSPHERE 3000 Series Carrier
3-3 Model 3616 DSU Installation and Circuit Pack Lock 3-6. . . . . . . . . . . . . . . . . . . . . . . .
3-4 V.35 Interconnect Cable Installation 3-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5 Addressing Example 3-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model 3615 DCP
4-1
SDCP and Model 3616 DSU Faceplate
4-2
4-3 Loopbacks 4-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D-1 Digital Network Connector D-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D-2 3600 Hubbing Device (3600-F3-300) D-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D-3 Model 3616 DSU 25-Pin EIA-232/25-Pin V.35
Rear Connector Plate (3000-F1-021) D-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D-4 V.35 Interconnect Cable (3000-F1-510) D-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D-5 EIA-232-D Crossover Cable (4951-035F) D-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D-6 V
E-1 Dial Backup for Received Data Errors (SyBC and SyBT) Application E-2. . . . . . . . . .
E-2 Dial Backup for Exceeded Load Thresholds (SyBC and SyBT) Application E-3. . . . .
E-3 Frame Relay and Simultaneous Diagnostic (DiDg) Application E-4. . . . . . . . . . . . . . . .
.35 Crossover Cable (321
1-178F) D-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
, Rear V
iew 3-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-7. . . . . . . . . . . . . . . . . . . .
2-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
iii3615-A2-GB20-20 December 1996
Page 9
COMSPHERE DualFlow Data Service Units
Table Page

List of Tables

1-1 General T 1-2 DSU T 1-3 V 1-4 4-Wire Switched 56 DBM T 1-5 2-Wire Switched 56 DBM T 2-1 2-2 3-1 3-2
4-1 Identity Descriptions 4-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2 4-3 Digital T 4-4 End-to-End T 4-5 Bit Error Rate T
4-6 Directory Entry and Password Characters 4-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7
5-1 DSU Configuration Options 5-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2 DSU Port Configuration Options 5-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3
5-4 DBM Port Configuration Options 5-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-5
5-6 Diagnostic General Configuration Options 5-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-7 Backup Configuration Options 5-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-1 DSU Status Indicators C-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-2 SDCP Status Indicators C-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-3 C-4 C-5 C-6 C-7 C-8 C-9
.32 DBM T
Model 3615 DSU Switch Settings LADS Connection Distances Model 3616 DSU Switch Settings Model 3616 DSU Jumper Straps
Backup Branch Menu Selections
Lead States
DBM Configuration Options
Diagnostic DBM Configuration Options
Device Health and Status Messages Expanded Health and Status Messages Subnetwork Health and Status Messages Command Progress Messages Dial Backup Progress Messages Command Error Messages Dial Backup Error Messages
echnical Specifications
echnical Specifications
echnical Specifications
echnical Specifications echnical Specifications
est Results
est Results
est Results
C-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-7. . . . . . . . . . . . . . . . . . . . . . . . .
1-8. . . . . . . . . . . . . . . . . . . . . . . . .
2-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
iv December 1996 3615-A2-GB20-20
Page 10
Table of Contents
Table Page
D-1 Model 3615 – Digital (DDS and 4-Wire Switched 56 kbps)
Network Connector Pin Assignments
D-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D-2 Model 3615 – Dial (Analog and 2-Wire Switched 56 kbps)
Network Connector Pin Assignments
3600 Hubbing Device Pin Assignments
D-3
3600 Hubbing Device CC IN/DC OUT Jack Pin Assignments
D-4 D-5 EIA-232/V D-6 V
.35 Connector Pin Assignments
.24 Connector Pin Assignments
D-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D-3. . . . . . . . . . . . . . . . .
D-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v3615-A2-GB20-20 December 1996
Page 11

Preface

About
This install and operate your COMSPHEREr Model 3615 or 3616 DualFlow data service unit (DSU), which is equipped with a dial backup module (DBM) – either a V.32 DBM, a 4-wire Switched 56 DBM, or a 2-wire Switched 56 DBM.
Be sure to read the safety and regulatory information at the beginning of this guide.
It is assumed that you are familiar with the functional operation of digital data communications equipment.
This Guide
user
’s guide provides the information needed to
How to Use This Guide
This guide provides basic information about your DSU, how to install it and verify that it is installed and operating correctly, how to operate the unit and its options, and how to configure it.
Two installation chapters are provided, one for the Model 3615 DualFlow DSU and one for the Model 3616 DualFlow DSU. Select the chapter that applies to your DSU.
Refer to the following chapters or appendices, as needed:
Chapter 1
Provides a general overview of the DualFlow DSU, the unit’s technical specifications, equipment warranty and support services information, and instructions for equipment return.
Chapter 3
Chapter 4
Chapter 5
Appendix A Provides a diagram for
Appendix B Summarizes the configuration
Appendix C Lists the DSU’
Appendix D
Appendix E Provides cable and connector
Appendix F Equipment List Glossary Refer
ence Car
d
Provides step-by-step instructions for installing your carrier-mounted Model 3616 DualFlow DSU.
Describes how to operate your DSU and its DBM.
Presents the basics of setting and changing configuration options and provides Configuration Option Tables, which provide the default (factory-loaded) settings and describe each configuration option and its possible settings.
navigating the DSU’ structure.
options for you.
identifies when they appear. Shows application
configurations and network hookups.
pin assignments.
s menu
s messages and
Chapter 2
Provides step-by-step instructions for installing your standalone Model 3615 DualFlow DSU.
vii3615-A2-GB20-20 December 1996
Page 12
COMSPHERE DualFlow Data Service Units
Related Documents
Other product documentation includes the following:
3000-A2-GA31 COMSPHERE 3000 Series
Carrier, Installation Manual
3000-A2-GB41 COMSPHERE –48 Vdc
Central Office Power Unit, Installation Guide
6700-A2-GB41 COMSPHERE 6700 Series
Network Management System, User’
s Guide, Security
Manager Featur
6700-A2-GY31 COMSPHERE 6700 Series
Network Management System, User’
s Guide
6800-A2-GB31 COMSPHERE 6800 Series
Network Management System, Communications Pr Support Command Refer Manual
Contact your sales representative for additional product documentation.
e Supplement
oducts
ence
Reference Documents
AT&T T
AT&T T
AT&T T
Bell Canada DCTE Specifications
Bell Communications Research T Reference Publication 41028
CCITT V.35 (ISO 2593)
EIA-232-D/V.24 (ISO 2110)
Integrated Network Corporation Compatibility
Bulletin CB-INC-101
Northern Telecom NIS S204-2e 1986
Pacific Bell PUB L-780035-PB/NB
Pacific Bell PUB L-780036-PB/NB
echnical Reference 41458 echnical Reference 61330 echnical Reference 62310 – 1987
echnical
viii December 1996 3615-A2-GB20-20
Page 13

About Your DualFlow DSU

Overview 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard Features 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DBM Features 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V.32 DBMs 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switched 56 DBMs 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Specifications 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Equipment Warranty and Support 1-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
Overview
The COMSPHEREr DualFlow data service unit (DSU) provides simultaneous digital data service (DDS) and backup connections to support Frame Relay and router
-based applications.
The DDS portion provides basic non-rate adapted, non-diagnostic access using the DSU’ The backup portion (either a V.32, 4-wire Switched 56, or 2-wire Switched 56 DBM) provides simultaneous rate-adapted, diagnostic access to the switched network.
T
wo versions are available:
The standalone Model DualFlow 3615 DSU is designed for desktop or shelf operation.
The carrier-mounted (nest- or rack-mounted)
Model DualFlow 3616 DSU is designed for operation in the COMSPHERE 3000 Series Carrier.
Each DualFlow DSU is equipped with an integral dial backup module (DBM) for operation over the Public Switched Telephone Network (PSTN), often referred to as the dial network, or the Switched 56
The following sections describe the DSU’ features, as well as the features of the integral DBMs. Refer to the appropriate section for DBM feature information.
s V
.35 connector.
kbps digital service.
s standard
Standard Features
The DualFlow DSU offers the following features:
Multispeed operation. The DSU operates at data
rates of 2.4, 4.8, 9.6, 19.2, 38.4, 56, and 64CC kbps full-duplex over the DDS network.
Two DTE connectors (interfaces) are provided:
and
EIA-232-D
connector for router-management data or backup; use the V
LADS operation.
area data set (LADS) (sometimes called a limited-distance modem, or LDM) at 2.4, 4.8, 9.6,
19.2, 38.4, 56, or 64 kbps.
NMS control. The DSU can be controlled by
COMSPHEREr 6700 or 6800 Series NMS. Both NMSs operate using Advanced Diagnostic protocol (ADp).
The Model 3615 DSU requires a hubbing device for connection to the NMS; the Model 3616 DSU is connected to the NMS through the shared diagnostic unit (SDU) in the COMSPHEREr 3000 Series Carrier.
V.35. Use the EIA-232-D
.35 connector for user data.
The DSU can operate as a local
echnical specifications of the DSU and various DBMs
T are near the end of this chapter.
1-13615-A2-GB20-20 December 1996
Page 14
COMSPHERE DualFlow Data Service Units
Diagnostic Control Panel control. The
Model 3615 DSU is controlled from its diagnostic control panel (DCP). The diagnostic control panel for the Model 3616 DSU, called a shared diagnostic control panel (SDCP), is installed in the 3000 Series Carrier information about the DSU on 2-line, 16-character liquid crystal display (LCD) and through light-emitting diode (LED) status indicators.
Except where a distinction is made, the term both types of diagnostic control panels, the
For more information about the 3000 Series Carrier or the SDCP Installation Manual. For more information about the 6700 or 6800 Series NMS, refer to your NMS documentation. These documents are identified in the section of the number you can call to order these documents.
, refer to the
Preface
. Both control panels display
NOTE
DCP
refers to
DCP
or the
COMSPHERE 3000 Series Carrier
, which also provides a telephone
SDCP
.
Related Documents
V.32 DBMs
The V.32bis 14.4 kbps dial backup module (referred to as V.32 DBM throughout this guide) is attached to the DSU. The V.32 DBM provides the following features:
Multispeed nondisruptive point-to-point
connections. The DBM provides point-to-point
service over the 2-wire dial network. Backup rates available are 2.4, 4.8, 9.6, 12.0, and 14.4 kbps. DBM and DDS connections can be active at the same time.
Independent operation.
installed on the DSU, the two are configured separately and most tests can be run on either independent of the other (e.g., you can run a test on the DBM while a test is running on the DSU).
Security. There are four levels of call setup
security:
,
W when an alarm is detected on the DDS line.
Management control.
from a 6700 or 6800 Series NMS, the DSU’ or it can be initiated automatically by the DSU-DBM.
None, Password, Callback, and Alarm.
ith Alarm, the DBM only answers incoming calls
Although the DBM is
Dial backup can be initiated
s DCP
,
DBM Features
DualFlow DSUs are ordered with one of the following
features:
V
.32bis 14.4 kbps dial backup module (DBM)
2-W
4-W
Refer to the appropriate section for specific DBM
features.
ire Switched 56 DBM ire Switched 56 DBM
DTR contr
control (DTRCallCon: Orig) backup, the DSU-DBM initiates dial backup when the DTE raises data terminal ready (DTR) to the DSU-DBM.
Rate Adaption.
can adapt its data rate to a low-speed application while operating over a higher speed switched circuit.
Port Async/Sync. The port asynchronous-to-
synchronous feature makes it possible to send asynchronous data over the synchronous network.
Nondisruptive Diagnostics.
nondisruptive diagnostics, the local DSU-DBM sends diagnostic data over the dial connection without interrupting or disrupting customer data.
Full tributary diagnostics. The DSU-DBM
supports a full complement of diagnostic tests and commands when a call is established on a backup line. Diagnostics can be addressed to and sent to a tributary from a 6700 or 6800 Series NMS workstation, or from the DCP of a control DSU.
ol setup. When configured for DTR call
W
ith this feature, the DSU-DBM
When set up to use
1-2 December 1996 3615-A2-GB20-20
Page 15
About Your DualFlow DSU
Switched 56 DBMs
The
Switched 56 DBM is attached to the DSU and offers dial backup capability through the Switched 56 kbps digital service. The Switched 56 DBM of following features:
Nondisruptive point-to-point connections. The
DBM sends its line data to the EIA-232 port, which is not used for DDS data. DBM and DDS connections can be active at the same time.
Independent operation. Although the DSU and
Switched 56 DBM are functionally integrated, they are configured separately and can run most tests independently (e.g., you can run a test on the DBM while a test is running on the DSU).
Network compatibility.
either the 2-wire or 4-wire version, provides service over compatible Switched 56 kbps switched services, such as A 56 kbps Service, MCI’ Service, Northern Telecom’ and US SPRINT’ 2-wire or 4-wire access, or local exchange carrier 2-wire or 4-wire switched access. This DBM operates at 56 kbps full-duplex, and uses proprietary rate adaption to support data rates of less than 56 kbps.
Security. The Switched 56 DBM offers four levels
of call setup security: and Alarm. Alarm allows the DBM to only answer incoming calls when there is a Facility Alarm on the DDS line.
DTR contr
control (DTRCallCon: Orig) backup, the DSU-DBM initiates dial backup when the DTE raises data terminal ready (DTR) to the DSU-DBM.
ol setup. When configured for DTR call
The Switched 56 DBM,
T&T’
s ACCUNET
s 56 kbps Switched Digital
s DataPatht service,
s VPN56 using either dedicated
None, Password, Callback,
r Switched
fers the
Management control.
be controlled from a 6700 or 6800 Series NMS, the
s DCP
DSU’
Rate Adaption.
can adapt its data rate to a low-speed application while operating over a higher speed switched circuit.
Port Async/Sync. The port asynchronous-to-
synchronous feature makes it possible to send asynchronous data over the synchronous network.
Nondisruptive Diagnostics.
nondisruptive diagnostics, the local DSU-DBM sends diagnostic data over the dial connection without interrupting or disrupting customer data.
Full tributary diagnostics. The DSU-DBM
supports a full complement of diagnostic tests and commands when a call is established on a backup line. Diagnostics can be addressed to and sent to tributaries from a 6700 or 6800 Series NMS workstation, or from the DCP of a control DSU.
, or automatically by the DSU-DBM.
Dial backup functions can
W
ith this feature, the DSU-DBM
When set up to use
Technical Specifications
T
ables 1-1
for the following:
General specifications that apply to all DualFlow
Specifications for the Model 3615 and 3616 DSU
Specifications for the V.32 DBM (Table 1-3)
Specifications for the 4-W
through 1-5 list the technical specifications
DSUs, regardless of the type of DBM installed (Table 1-1)
only (Table 1-2)
ire Switched 56 DBM
(Table 1-4)
Specifications for the 2-W
(Table 1-5)
ire Switched 56 DBM
1-33615-A2-GB20-20 December 1996
Page 16
COMSPHERE DualFlow Data Service Units
Specifications Criteria
APPROVALS
FCC Part 15 FCC Part 68 UL
3615 DualFlow DSU 3616 DualFlow DSU,
3000 Series Carrier
CSA
Safety
3615 DualFlow DSU
3616 DualFlow DSU,
3000 Series Carrier
Emissions
Bell Canada
Table 1-1
General Technical Specifications
Class A digital device AW292J-61661-DD-N
Listed UL 1950, second edition Recognized Component UL 1950, second edition
Certified CSA 22.2, No. 950-M89 Certified Component CSA 22.2, No. 950-M89
CSA 108.8 – M1983, Class A digital apparatus “DCTE Specifications,” July 1989, Issue 1
AC POWER REQUIREMENTS
3615 DualFlow DSU 3616 DualFlow DSU 3000 Series Carrier (16 DualFlow DSUs,
plus SDU and fan module)
DTE INTERFACE
3615 DualFlow DSU
25-pin D-subminiature connector 34-pin connector
3616 DualFlow DSU with 25-Pin V.35 Interface
Uses a Rear Connector Plate with two 25-pin D-subminiature connectors.
ENVIRONMENT
Operating Temperature Storage Temperature Relative Humidity Shock and Vibration
HEAT DISSIPATION (MAX.) AT 115 VAC
3615 DualFlow DSU 3616 DualFlow DSU 3000 Series Carrier (16 DualFlow DSUs
plus SDU and fan module)
24 Vac (CT), 60 HZ ± 3 (0.115 amp, 9.5 watts at 115 Vac) 24 Vac (CT), 60 Hz +3 (0.080 amp, 8.0 watts at 115 Vac) 90—132 Vac, 60 Hz +3 (1.650 amp, 165 watts at 115 Vac)
EIA-232-D/CCITT V.24 (ISO 2110) CCITT V.35 (ISO 2593)
EIA-232-D/CCITT V.24 (ISO 2110) CCITT V.35 (ISO 2593)
(A V.35 Interconnect Cable is required to use the V.35 connector. The cable provides an interface between the DSU’s 25-pin D-type connector and the DTE cable’s V.35 connector.)
32°
to 122
° F (0°
to 50
° C)
to 158
–4° 5%—95% (noncondensing) Withstands normal shipping and handling
29.00 Btu/hr
27.30 Btu/hr
563.00 Btu/hr
° F (–20°
to 70
° C)
NMS COMPATIBILITY
1-4 December 1996 3615-A2-GB20-20
COMSPHEREr 6700 Series NMS, Release 4.0 or greater COMSPHEREr 6800 Series NMS, Release 4.1.5 or greater
Page 17
About Your DualFlow DSU
Table 1-2
DSU Technical Specifications
Specifications Criteria
APPLICATION Full- or half-duplex data transmission via point-to-point DDS network, or
local area data channel
COMMUNICATION LINE Leased or private 4-wire DDS line DATA RATES
Digital Services (DDS, ASDS) LADS When timing is external (provided by the
DTE), the DTE’s clock must be within these ranges.
DDS NETWORK INTERFACE
3615 DualFlow DSU 3616 DualFlow DSU
2.4, 4.8, 9.6, 19.2, 38.4, 56, and 64CC kbps
2.4, 4.8, 9.6, 19.2, 38.4, 56, and 64 kbps 64 kbps " 11 bps
56 kbps " 9 bps
38.4 kbps " 4 bps
19.2 kbps " 5 bps
9.6 kbps " 1 bps
4.8 kbps " 0 bps
2.4 kbps " 0 bps
8-pin modular jack, USOC RJ48S (One or two) 50-pin connector, USOC RJ48T
DIAGNOSTIC INTERFACE
3615 DualFlow DSU 3616 DualFlow DSU
NETWORK COMPATIBILITY
ANSI T1.410 – 1992 and AT&T Technical Reference 62310 – 1987
Integrated Network Corporation Compatibility Bulletin CB-INC-101, and Pacific Bell publications PUB L-780035-PB/NB and PUB L-780036-PB/NB
DSU COMPATIBILITY
Primary Channel
Requires 3600 Hubbing Device which provides two 8-pin modular jacks Via the SDU in the COMSPHEREr 3000 Series Carrier
2.4, 4.8, 9.6, 56, and 64CC kbps
6,
19.2 kbps loop at levels of +
All Paradyne digital products and other products that are compliant with AT&T Technical Reference 62310 – 1987
0, or –10 dBm
1-53615-A2-GB20-20 December 1996
Page 18
COMSPHERE DualFlow Data Service Units
Table 1-3
V.32 DBM Technical Specifications
Specifications Criteria
RINGER EQUIVALENCE NUMBER (REN) DBM option 0.7B APPLICATION Full- or half-duplex data transmission via analog 2-wire dial network,
point-to-point
MODULATION AND FREQUENCY At 14.4 and 12 kbps: CCITT V.32bis, 1800 Hz
At 4.8 and 9.6 kbps: CCITT V.32, 1800 Hz At 2.4 kbps: CCITT V.22bis, 2400 Hz
COMMUNICATION LINE 2-wire analog (PSTN) line PORT RATES Async or Sync rates: 14.4, 12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.4, 4.0, 2.4, 2.0,
DATA RATES 2.4, 4.8, 9.6, 12, 14.4 kbps DBM COMPATIBILITY If Call Setup is set for Callback or Password security, then the device is
APPROVALS
DOC
Certification (PSTN) Load Number
RECEIVE VF INTERFACE
Dynamic Range
V.32 2-wire PSTN
Impedance
SWITCHED NETWORK INTERFACE
3615 DualFlow DSU
and 1.2 kbps Other asynchronous rates (e.g., 150, 300, 600, and 1800 bps) can be
obtained through oversampling
Asynchronous rates support CCITT V.14 extended rate range at 8 to 12 bits per character percent overspeed/underspeed compensation at 10 bits per character)
compatible with a 3600 Series V.32 DBM only. If Call Setup is set for Alarm or None, then
used. Also, V.22bis at 2.4 kbps can be used.
230 3684 A 7
43 to
–10 dBm
600
6-pin modular jack
Permissive: USOC RJ11C
8-pin modular jack
Programmable: USOC RJ45S
, including the
start
and
stop
any
V.32 modem can be
bit (+2.3, –2.5
3616 DualFlow DSU
TRANSMIT VF INTERFACE
Signal Level
V.32 2-wire Dial (PSTN)
Impedance
1-6 December 1996 3615-A2-GB20-20
(One or two) 50-pin connector
Permissive: USOC RJ21X Programmable: USOC RJ27X
Permissive: –9 dBm Programmable:
600
–12 to
0 dBm (set by a resistor in the telco jack)
Page 19
About Your DualFlow DSU
Table 1-4
4-Wire Switched 56 DBM Technical Specifications
Specifications Criteria
APPLICATION Full- or half-duplex data transmission via 56 kbps switched services
compatible with AT&T, MCIr, and US SPRINTr using 4-wire switched access to a local exchange carrier (LEC) or an inter-exchange carrier (IEC)
COMMUNICATION LINE A dedicated 4-wire access or a local exchange carrier 4-wire switched
access
PORT RATES Async or Sync rates: 56, 48, 38.4, 32, 28.8, 19.2, 18.8, 18.0, 16.8, 14.4,
12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.4, 4.0, 2.4, 2.0, and 1.2 kbps Other asynchronous rates (e.g., 150, 300, 600, and 1800 bps) can be
obtained through oversampling Asynchronous rates support CCITT V.14 extended rate range at
8 to 12 bits per character percent overspeed/underspeed compensation at 10 bits per character)
, including the
start
and
stop
bit (+2.3, –2.5
DATA RATES 56 kbps
(Note that the 4-wire Switched 56 DBM or 3600 Series DBM-S uses proprietary rate adaption to support data rates of less than 56 kbps.)
DBM COMPATIBILITY If Call Setup is set for Callback or Password security
device is compatible with a 3600 Series Switched 56 DBM only. If Call Setup is set for Alarm or None, then any Switched 56 kbps
terminal interface unit (TIU) can be used.
SWITCHED 56 KBPS NETWORK INTERFACE
3615 DualFlow DSU 3616 DualFlow DSU
NETWORK COMPATIBILITY AT&T Technical References 41458 and 61330
8-pin modular jack, USOC SJA56 (One or two) 50-pin connector, USOC SJA57
, then the
1-73615-A2-GB20-20 December 1996
Page 20
COMSPHERE DualFlow Data Service Units
Table 1-5
2-Wire Switched 56 DBM Technical Specifications
Specifications Criteria
APPLICATION Full- or half-duplex data transmission via 56 kbps switched services
compatible with AT&T, US SPRINTr, and MCIr using DataPatht 2-wire switched access to a local exchange carrier (LEC) or an interexchange carrier (IEC)
COMMUNICATION LINE A dedicated 2-wire access or a local exchange carrier 2-wire switched
access
PORT RATES Async or Sync rates: 56, 48, 38.4, 32, 28.8, 19.2, 18.8, 18.0, 16.8, 14.4,
12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.4, 4.0, 2.4, 2.0, and 1.2 kbps Other asynchronous rates (e.g., 150, 300, 600, and 1800 bps) can be
obtained through oversampling Asynchronous rates support CCITT V.14 extended rate range at
8 to 12 bits per character percent overspeed/underspeed compensation at 10 bits per character)
, including the
start
and
stop
bit (+2.3,
–2.5
DATA RATES 56 kbps
uses proprietary rate adaption to support data rates of less than 56 kbps.)
DBM COMPATIBILITY If Call Setup is set for Callback or Password security, then the device is
compatible with a 3600 Series Switched 56 DBM only. If Call Setup is set for Alarm or None, then any Switched 56 kbps
terminal interface unit (TIU) can be used.
SWITCHED 56 KBPS NETWORK INTERFACE
3615 DualFlow DSU 3616 DualFlow DSU
APPROVALS
DOC
Certification Number Load Number
NETWORK COMPATIBILITY
6-pin modular jack, USOC SJA48 (One or two) 50-pin connector
230 5870 A 0
Northern Telecom NIS S204-2e
Equipment Warranty and Support
(Note that the 2-wire Switched 56 DBM or 3600 Series DBM-D
1986
ia T
V
elephone:
Call our automated call system to receive current information via fax or to speak with a company representative.
If you experience trouble with this equipment, please contact your sales or service representative (as appropriate) for repair or warranty information. If the
— Within the U.S.A., call 1-800-870-2221 — International, call 813-530-2340
product needs to be returned to the company service center for repair, contact them directly for return instructions using one of the following methods:
V
Via the Internet:
eb site at http://www
W
1-8 December 1996 3615-A2-GB20-20
isit the Paradyne World Wide
.paradyne.com
Page 21
Installing the Model 3615
Overview 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before you Begin 2-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to Change Hardware Straps 2-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Where to Place the DSU 2-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the DSU 2-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-up Routine 2-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the Network 2-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the NMS 2-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the Dial (or PSTN) Network 2-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the Switched 56 kbps Network 2-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the DDS (or LADS) Network 2-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting the DSU to a Router 2-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Addressing the Unit 2-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tributary DSU Addressing 2-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying Operation and Testing Connections 2-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying DBM Operation 2-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying Network Addresses 2-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying the Network 2-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Other Tests 2-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
The Model 3615 DualFlow DSU is designed for desktop operation and is delivered ready to connect to the network. It is configured as a tributary DSU for operation at 56 kbps on a point-to-point circuit.
Installation consists of the following steps, which should be performed in the order listed.
DualFlow DSU
Although the Model 3615 DualFlow DSU is designed for desk or table-top operation, you can order an ACCULINKr 3100 Series CSU wall-mount adapter if you want to mount the DSU on a wall, an equipment shelf, a 19-inch RS-310-C or 23-inch AT&T DATAPHONEr equipment cabinet. Refer to Appendix F to order the adapter.
2
Physical installation
Hardware straps
Electrical connection
Network diagnostic connection
Software configuration
DDS network (or LADS) connection
Dial network (or PSTN) connection
Router connection
Verification testing
Before You Begin
Your
installation site should be clean, well-lighted,
well-ventilated, and free from environmental extremes.
A dedicated grounded ac outlet that is protected by a circuit breaker should be installed within 6 feet of the DSU’s planned location. The outlet should be capable of supplying 90 to 132 Vac 60 Hz (U.S. and Canada). At the branch site, the circuit must be capable of supplying a minimum of 2 amperes at 115 Vac. Refer to the Technical Specifications section in Chapter 1 for additional power requirements.
2-13615-A2-GB20-20 December 1996
Page 22
COMSPHERE DualFlow Data Service Units
CAUTION
The ac transformer contains a 3-wire grounding-type plug which has a grounding pin. This is a safety feature. Do not defeat the purpose of the grounding plug by modifying it or by using an adapter.
Prior to installation, use an outlet tester to check the ac receptacle for earth ground. If the power source does not provide a ground connection, consult an electrician to determine another method of grounding the DSU before proceeding with the installation.
Before connecting the DSU, you need to contact the telephone company to coordinate your installation before connecting the DSU to the DDS or Switched 56 kbps network. The DSU can only be operated at the data rate for which access to the DDS network is provided. In addition, the DSU must be connected to the dial network.
Refer to the notice at the fr compliance with FCC, Bell Canada, and Canadian DOC rules.
No on-site assembly of the DSU is required. However, installation should not proceed if any of the following is missing:
A power cord with table-top ac transformer
A 14-ft cable for connection to the DDS network,
with an 8-pin RJ48S modular plug on each end
A 14-ft cable for connection to the permissive dial
network, with a 6-pin RJ11C modular plug on each end (feature number 3600-F3-503)
For programmable services, the following dial interface cable should have been ordered.
Programmable (RJ45S) – an 8-pin modular plug at
each end (feature number 4400-F1-
For Canadian purchasers, an 8-pin RJ48S connector is on one end while a 6-pin connector is on the other is required (order feature number 3000-F1-006).
ont of this guide to ensur
54x)
e
Contact your service representative if any of these items is missing from the shipping container the programmable dial interface cable.
Since your DualFlow DSU is equipped with a DBM, you may need to change the DSU’s hardware straps before installing the DSU.
, or to order
How to Change Hardware Straps
HANDLING
STA
TIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static control precautions to prevent damage to equipment. If you are not sure of the proper static control precautions, contact your near representative.
The Model 3615 DSU has a switch located behind its diagnostic control panel (DCP). This switch contains two straps, one that controls the permissive or programmable connection for the DBM, and one that controls the frame-to-signal grounds. Table 2-1 shows the DSU’s switch settings. Refer to Figure 2-1 and follow these steps if you need to change one of these straps.
PRECAUTIONS
FOR
est sales or service
. Procedure
1. With your thumbs under the edge of the front bezel, firmly press upward to lift the bezel from the tabs securing it in place.
2.
Swing the front bezel up and set the bezel aside.
3. Refer to Table 2-1 to determine which switch needs to be changed. Then, using a small instrument, carefully change the position of the switch.
4. Reinsert the front bezel’ and swing the bezel down. Snap the bezel back into place.
s hinge tabs into position
2-2 December 1996 3615-A2-GB20-20
Page 23
FRONT BEZEL
COMSPHERE 3615
SNAP TABS
Installing the Model 3615 DualFlow DSU
SWITCH 1
HINGE TAB
LOCATIONS
496-14499-01
Figure 2-1. Model 3615 DSU Hardware Switch Location
Table 2-1
Model 3615 DSU Switch Settings
Switch Position Switch Setting Function
ON
(default)
S1-1
Off Programmable V.32 DBM transmit level between –12 dBm and
Permissive V.32 DBM transmit output level of –9 dBm
0 dBm
ON Frame ground (FG) connected to signal ground (SG)
S1-2
Off
(default)
ON is to the rear as you face the front of the DSU. Off is to the front.
FG connected to SG through 100 ohm resistor
2-33615-A2-GB20-20 December 1996
Page 24
COMSPHERE DualFlow Data Service Units
Where to Place the DSU
As mentioned earlier 6 feet of a dedicated grounded ac outlet that is protected by a circuit breaker.
The distance between the DSU and its DTE must be within EIA-232-D/V.24 limits, or V.35 limits if operating the DSU at speeds greater than 19.2 kbps.
For the EIA-232 connector, the typical maximum
distance is 50 feet at speeds less than or equal to
19.2 kbps. If a longer distance is needed, use high quality
, low capacitance cable and ensure that the effective shunt capacitance of the circuit (measured at the DSU and including the capacitance of the cable and the DTE) does not exceed 2500 picofarads, as specified in EIA-232-D.
For the V
recommended between the DSU and the DTE is nominally 1000 feet.
Allow 1 to 2 feet of clearance around the DSU for
access and cable connections during installation.
.35 connector
, the DSU must be placed within
, the maximum distance
Installing the DSU
Before installing the DSU, label the circuit breaker that protects the ac wall outlet, and make sure that it is set to ON. To proceed with the installation:
. Procedure
1.
Place the DSU in its planned location. Make sure the ventilation slots are not blocked.
2. At the rear of the DSU (Figure 2-2), insert the ac transformer, circular plug into the interface labeled POWER.
3. Plug the ac transformer’s 3-prong plug into the ac wall outlet.
CAUTION
Only use the power transformer designed for the Model 3615 DSU. Using other transformers may result in personal injury or damage to the equipment.
Figure 2-2. Model 3615 DSU Electrical Connection
2-4 December 1996 3615-A2-GB20-20
Page 25
Installing the Model 3615 DualFlow DSU
Power-Up Routine
When power is applied, the DSU:
Runs a Device T
During the tests, all indicators on the DCP light briefly and the message on the liquid crystal display (LCD).
Displays the results of each test momentarily as
Pass, Fail, or Abrt. ( T
est was aborted because a network loopback was in progress during the power-up procedure.) These tests take about 20 seconds to complete.
If the DSU or DBM fails this test, follow these steps. Refer to Appendix A as you perform the procedures described in this guide. Refer to Chapters 4 and 5 for additional examples and procedures.
est on itself and the DBM.
Power-Up T
Abrt indicates that the Device
ests
appears
. Procedure
1.
Press the Select
2. Press the
3. (Configuration) branch into view.
4. Press the function key directly below Confg. Press the F1 key to select
5. Options).
Load from screen appears.
The
key to return to the top-level menu.
Local (F1 key).
key to scroll the Confg
Opts (Configuration
Press the F1 key to
7. configuration.
Save to
The
8. Save the selected configuration to Activ (F1 key). Press the
9. then select
10.
Select The Run T
11.
Select the device that Failed: the DSU or DBM.
12. Press the F2 key to run the Device T The device should pass.
13. Should the device fail, contact your service representative (see Support section in Chapter 1).
screen appears.
Local
Test (F3).
est on
SAVE
the selected
key to return to the top-level menu,
again.
screen appears.
est again.
Equipment W
arranty and
Connecting to the Network
The DSU provides three interfaces (often called jacks). One jack connects the DSU to the 6700 or 6800 Series NMS, one connects the DSU to the dial (or public switched telephone network – PSTN) network, and one connects the DSU to the DDS network. Follow the appropriate procedure when making your network connections.
6.
Press the configurations into view appropriate configuration.
SyBC (Synchronous Backup for a Control
DSU) for a control when the router controls backup.
SyBT (Synchronous Backup for a Tributary
DSU) for a tributary when the router controls backup.
DiDg (Dial Diagnostics) for asynchronous
router-management data to be sent over the EIA-232 port via the DBM connection and user data over the V.35 port via the DDS connection.
key to bring the factory-loaded unit
, and select the
2-53615-A2-GB20-20 December 1996
Page 26
COMSPHERE DualFlow Data Service Units
a
Connecting to the NMS
A 3600 Hubbing Device is required to connect the control DSU to the 6700 or 6800 Series NMS. When connected to the NMS, the DSU can be controlled and configured from the NMS rather than from the DCP alone.
. Procedure
1. Plug the 4-pin modular plug of the 3600 Hubbing Device (Figure 2-3) into the DSU jack labeled CC/DC.
Plug one end of an M6BJ cable into the hubbing
2. device jack labeled
3. Plug the other end of the 6-pin M6BJ cable into the 6-pin end of the 873A adapter.
4. Plug the D-type end of the 873A adapter into the appropriate 6700 or 6800 Series NMS jack.
Refer to your COMSPHERE 6700 or 6800 Series NMS documentation to control and configure the DSU from the NMS.
CC IN/DC OUT
.
Connecting to the Dial (or PSTN) Network
If your DSU is equipped with a V.32 DBM, refer to
Figure 2-4 as you follow these steps.
. Procedure
1. Plug either end of the dial (analog) interface cable
into the DSU jack labeled BACKUP.
Permissive service – telephone cord with 6-pin
modular RJ1
Programmable service – telephone cord with
8-pin RJ45S plug
2. Plug the other end of the cable into the modular jack provided by the telephone company RJ1
1C (permissive) or USOC RJ45S
(programmable).
3. If your site has programmable service, verify that the DSU’ OFF position.
1C plug
, USOC
s hardware strap S1-1 is switched to the
NMS NETWORK
CONNECTION
LOW VOLTAGE
AC POWER IN
TO
NMS (873A)
3000HUBBING DEVICE
MODEL #3000-F3-300
Figure 2-3. Model 3615 DSU
NMS Connection
HUBBING
DEVICE
CC/DC
496-14576
Figure 2-4. Model 3615 DSU
Dial (PSTN) Network Connection
2-6 December 1996 3615-A2-GB20-20
Page 27
Connecting to the Switched 56 kbps Network
NOTE
Before connecting the DSU to the Switched 56 kbps network, ensure that approved primary protectors have been installed on the circuit in accordance with Article 800 of the National Electric Code, NFPA 70, in the United States and Section 60 of the Canadian Electric Code, Part 1, in Canada.
Installing the Model 3615 DualFlow DSU
If the DSU is equipped with a 4-wire Switched 56 DBM, an 8-pin cable is provided; if a 2-wire Switched 56 DBM, a 6-pin cable is provided.
WARNING
Do not insert the 2-wire Switched 56 kbps plug into an RJ11C jack. This type of jack is intended for analog public switched telephone network (PSTN) devices. Doing so may cause equipment damage and harm to the telephone network.
To
make a physical connection to the Switched 56 kbps
network, refer to Figure 2-5 as you follow these steps.
. Procedure
1. Plug either end of the Switched 56 kbps network interface cable into the DSU jack labeled BACKUP.
Figure 2-5. Model 3615 DSU
Switched 56 kbps Network Connection
Connecting to the DDS (or LADS) Network
NOTE
Before connecting the DSU to the DDS network, ensure that approved primary protectors have been installed on the circuit in accordance with Article 800 of the National Electric Code, NFPA 70, in the United States and Section 60 of the Canadian Electric Code, Part 1, in Canada.
Refer
to Figure 2-6 as you follow these steps.
For the 2-wir
6-pin cable.
For the 4-wir
8-pin cable.
2. Plug the other end of the cable into the modular jack provided for the Switched 56 kbps network connection.
e Switched 56 DBM
e Switched 56 DBM
, use the
, use the
2-73615-A2-GB20-20 December 1996
Page 28
COMSPHERE DualFlow Data Service Units
Data Rate
. Procedure
1. Plug the DDS network interface cable into the DSU jack labeled
LINE.
U.S.
– select either end of the cable
Canada – select the 8-pin end
2. Plug the other end of the cable into the modular jack (USOC RJ48S) provided by the circuit provider.
If the remote DSU is also connected to the network, the
s green
DSU’ goes of a
No Signal
OK indicator lights and the Alrm indicator
f. The Health and Status screen no longer displays
message.
If connecting the DSU to a LADS network, there are distance limitations that govern the use of DSUs on the network. T
able 2-2 summarizes these limitations.
LADS Connection Distances
Data Rate
(kbps)
2.4 20.0
19 22 24 26
mi
(32.2 km)
Figure 2-6. Model 3615 DSU DDS (LADS)
Table 2-2
Wire Gauge (AWG)
16.6 mi
(26.7 km)
(20.5 km)
12.7 mi
Network Connection
9.4 mi
(15.1 km)
4.8
9.6
1
19.2
38.4 1
56
64
1
Power level is –10 dBm.
19.4 mi
(31.2 km)
15.2 mi
(24.5 km)
1
1.8 mi
(19.0 km)
1.2 mi
(18.0 km)
9.2 mi
(14.8 km)
9.2 mi
(14.8 km)
12.7 mi
(20.5 km)
9.7 mi
(15.6 km)
7.5 mi
(12.1 km)
6.5 mi
(10.5 km)
5.4 mi
(8.7 km)
5.4 mi
(8.7 km)
9.6 mi
(15.4 km)
7.3 mi
(11.7 km)
5.7 mi
(9.2 km)
4.6 mi
(7.4 km)
3.8 mi
6.2 km)
3.8 mi
(6.2 km)
7.1 mi
(11.5 km)
5.6 mi
(9.0 km)
4.2 mi
(6.8 km)
3.2 mi
(5.1 km)
2.8 mi
(4.5 km)
2.8 mi
4.5 km)
2-8 December 1996 3615-A2-GB20-20
Page 29
Installing the Model 3615 DualFlow DSU
Connecting the DSU to a Router
The DualFlow DSU transmits user data through its V.35 interface and diagnostic or user data through its EIA-232-D/V
.24 interface. Cabling is based upon the preset configuration (SyBC, SyBT, or DiDg) selected in the Opts subbranch (Config branch).
Figure 2-7 shows the DualFlow DSU’s rear panel. Refer to this figure as you connect the DSU to the router. Appendix E shows examples common to the DSU-to­router application configurations.
. Procedure
1. Connect the plug end of the router’ the DSU’
ighten the two holding screws.
T
s V
.35 connector.
s V
.35 cable to
V.35
INTERFACE
2. Connect the other end of the router’ the router’s primary serial port.
T
3. Connect the plug end of the router’s EIA-232 cable to the DSU’s EIA-232-D/V.24 connector.
T
4. Connect the other end of the router’s EIA-232 cable to the router:
T
EIA-232-D/V.24
INTERFACE
s V
.35 cable to
ighten any holding screws.
ighten any holding screws.
If the DSU is to be configur
ed using the SyBC
or SyBT configuration, connect to the router’s
secondary serial port.
If the DSU is to be configur configuration, connect to the router’
ed using the
s console
DiDg
port.
ighten any holding screws.
DiDg CONFIGURATION:
TO ROUTER
CONSOLE PORT
(ROUTER-MANAGEMENT
SECONDARY SERIAL PORT
(BACKUP OR OVERFLOW
DATA)
SyBC OR SyBT
CONFIGURATION:
TO ROUTER
DATA)
DSU
CC
LOW
VOLTAGE
AC POWER
IN
TO NMS
(CONTROL
DEVICE
ONLY)
3000HUBBING DEVICE
MODEL #3000-F3-300
Figure 2-7. Router Connection
TO ROUTER
PRIMARY SERIAL PORT
(USER DATA)
496-14498-01
2-93615-A2-GB20-20 December 1996
Page 30
COMSPHERE DualFlow Data Service Units
Addressing the Unit
A
unique address must be assigned to each control and tributary DSU in your network. Y within the range of 1 through 255.
NOTE
Do not assign the number 192 as a network address. This number is reserved as a broadcast address.
The
DBM requires a separate address, which is automatically assigned by the DSU. The address assigned a DBM is the DSU’ address is 1, the assigned DBM address will be 2).
The numbers 191 and 255 cannot be assigned to a DSU that has a DBM. However, addresses can be assigned in any order; they do not have to be sequential.
It is recommended that only
odd-numbered
assigned to DSUs so that
even-numbered addresses
reserved for DBMs
s address, plus 1 (e.g., if the DSU’s
NOTE
ou can assign an address
addresses be
are
.
Tributary DSU Addressing
Tributary control DSU accesses its tributary via an active backup connection by specifying the tributary’
The 6700 or 6800 Series NMS accesses the DSU via its network address. To access a tributary DSU, first addresses the control, then the tributary issued from the NMS takes the format of control channel/control DBM network address/tributary network address. This is called link-level network addr
Figure 2-8 shows an example of DSU and DBM addressing, as well as link-level network addressing.
Refer to Chapter 4 to learn how to set the DSU’s network address.
DSU addresses are user
-definable. The
s address.
the NMS
. An address
essing.
Verifying Operation and Testing Connections
Verification testing should be performed after any installation.
After installing and configuring the circuit (including control and tributary DSUs, the DDS network, the DBMs and their dial connections), perform the following series of tests from the contr (using either the DCP or NMS).
Next, test the tributary DBM for dial tone, and verify that the DSU can place and receive calls.
ol DSU to verify network operation
Figure 2-8. Addressing Example
2-10 December 1996 3615-A2-GB20-20
Page 31
Verifying DBM Operation
A
backup connection must be established to verify that the switched network is functioning. Then, perform the Digital T
est by selecting the DBM
path.
. Procedure
1.
Select
Local (F1).
Select
2.
3.
4.
5.
6.
7.
8.
9.
10. Select the amount of time you want the test to run
Bckup (F2).
Select
Dial
to establish a dialed call to the
tributary. Refer to Chapter 4 for the procedure for entering
telephone numbers. Press the
to the dial circuit. Press the Select Select Select Select
in hours: minutes: seconds (hh:mm:ss).
Press the cursor to the digit to be changed.
key
key twice.
Test (F3). DBM (F2). DT
(F3).
Start (F1).
or key to move the blinking
, then select
!Cnnct
to switch
Installing the Model 3615 DualFlow DSU
Select
11.
12.
13.
14.
Enter (F3).
DBM runs the test. When
Command Complete
key
Select
Displ (F1) to display the results of the test.
Press the
.
Please wait
key to scroll through the test results.
appears as the
appears, press the
Verifying Network Addresses
Access the DSU’s identity (ID) subbranch
tributary DSU
addressed. Refer to Chapter 5 for an example using the DCP, if needed.
to ensure that the DSU is properly
for the
. Procedure
Select
1.
2. Enter the tributary’
3.
4.
5.
6.
7. Verify that the correct address has been entered.
Remot (Remote branch).
Select
Stat (Status branch).
Press the Select Press the
key until ID
ID.
key until
s network address.
appears.
Network Addr
appears.
Press the F1 (" ) key to increment the digit
(1 through 9).
Press the F2 (# ) key to decrement the digit.
2-113615-A2-GB20-20 December 1996
Page 32
COMSPHERE DualFlow Data Service Units
Verifying the Network
Perform
to ensure that the network is functioning.
a Health and Status check on the DDS circuit
. Procedure
1.
Select
Local (F1).
Select
2.
3.
4.
5.
6.
7.
8.
No error messages should appear Appendix C, the section, should there be a problem with the DDS Line.
Stat (F1).
Select
H/S (F1).
Select
Devic (F1).
Press the Select Select Select
key to return to the top-level menu.
Local (F1). Bckup (F2). DrBU to drop the backup call.
Device Health and Status Messages
. Refer to
Other Tests
The
following lists the tests available on your DSU. Refer to the T test information, as well as more detail on how to configure and operate the DSU. Refer to Appendix A to determine how best to access each test.
Digital Loopback (DL)
Remote Digital Loopback (RL) – DBM only
Bilateral Loopback
Digital T
End-to-End Test (EE) – DBM only
est Branch
Device T Local Loopback DTE Loopback
Bit Err Lamp T
est (Devic)
est
(DT) – DBM only
or Rate T
est (Lamp)
section of Chapter 4 for further
(LL) – DSU only
(DTE)
est (BERT)
2-12 December 1996 3615-A2-GB20-20
Page 33
Installing the Model 3616
Overview 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before you Begin 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to Change Hardware Straps 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the DSU 3-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-up Routine 3-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the Network 3-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the NMS 3-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the Dial (or PSTN) or Switched 56 kbps Network 3-8. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to the DDS (or LADS) Network 3-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting the DSU to a Router 3-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Addressing the Unit 3-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tributary DSU Addressing 3-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying Operation and Testing Connections 3-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To Connect the SDCP to a DSU 3-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying Network Addresses, the Network, and DBM Operation 3-12. . . . . . . . . . . . . . . . . . . . . . . . . . .
Other Tests 3-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
A Model 3616 DualFlow DSU is designed for installation in a COMSPHERE 3000 Series Carrier, which supplies power and provides the interfaces for connecting to the DDS or dial networks. Up to 16 DSUs can be installed in the carrier. Refer to the COMSPHERE
3000 Series Carrier
carrier and installation information.
The DSU is delivered ready to install in the carrier. It is configured as a control DSU for operation at 56 kbps on a point-to-point circuit.
, Installation Manual for additional
DualFlow DSU
Installation of the DSUs and carrier-related equipment consists of the following steps, which should be performed in the order listed.
Hardware straps
DSU physical installation
Network diagnostic connection
Software configuration
DDS network (or LADs) connection
Dial network (or PSTN) connection
3
A rear connector plate, shipped with the DSU, is installed onto the rear of the carrier. The rear connector plate contains two connectors: connector and a 25-pin V.35 connector DSU can be removed from the front of the carrier without disconnecting the DTE cables.
a 25-pin EIA-232-D/V.24
. Once installed, the
Router connection
Verification testing
3-13615-A2-GB20-20 December 1996
Page 34
COMSPHERE DualFlow Data Service Units
Before You Begin
The COMSPHERE 3000 Series Carrier should already be installed properly and be operational, with a functioning shared diagnostic control panel (SDCP). An SDCP (installed in the carrier) is required for installation and maintenance of the Model 3616 DSU. For installation information, see the Installation Manual.
A fan module may also be needed to dissipate heat. Refer to the Fan Module Installation of the
COMSPHERE 3000 Series Carrier
Manual to determine whether a fan is required.
The distance between your DTE and the DSU must be within EIA-232-D/V.24 or V.35 limits.
For the EIA-232 connector, the maximum
recommended distance is 50 feet. If operating at 56 kbps the maximum distance is 34 feet for shielded cable, and 68 feet for unshielded cable. When a Switched 56 DBM is installed, ensure that the effective shunt capacitance of the circuit (measured at the DSU and including the capacitance of the cable and the DTE) does not exceed 1250 picofarads.
For the V
maximum distance between a DTE and DSU is nominally 1000 feet.
Contact the telephone company to coordinate your installation before connecting the DSU to the DDS, Switched 56 kbps, or dial network. The DSU can only operate at the data rate for which access to the DDS or dial network is provided.
this guide to ensur and Canadian DOC rules.
COMSPHERE 3000 Series Carrier
section in Chapter 3
, Installation
.35 connector
e compliance with FCC, Bell Canada,
, the recommended
Refer to the notice at the fr
,
ont of
How to Change Hardware Straps
HANDLING
STA
TIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static control precautions to prevent damage to equipment. If you are not sure of the proper static control precautions, contact your near representative.
The Model 3616 DSU has several hardware straps that control the permissive or programmable connection when a DBM is installed, the T the external interface leads (used with a – Office Power Unit).
Refer to Figure 3-1 to locate the switch and jumper locations. If a V.32 DBM is installed, refer to Table 3-1 to determine which switch needs to be changed, if any to Table 3-2 to determine whether these jumper straps need to be changed.
PRECAUTIONS
FOR
est sales or service
est Mode Indication leads, and
48 Vdc Central
. Refer
3-2 December 1996 3615-A2-GB20-20
Page 35
Installing the Model 3616 DualFlow DSU
Figure 3-1. Model 3616 DSU Switch and Jumper Locations
Table 3-1
Model 3616 DSU Switch Settings
Switch Position Switch Setting Function
ON
-
S1-1
S1-2
ON is to the rear as you face the front of the DSU. Off is to the front.
(default)
Off Programmable V.32 DBM transmit level between –12 dBm and
ON Frame ground (FG) connected to signal ground (SG)
Off
(default)
Permissive V.32 DBM transmit output level of –9 dBm
0 dBm
FG connected to SG through 100 ohm resistor
3-33615-A2-GB20-20 December 1996
Page 36
COMSPHERE DualFlow Data Service Units
Strap
Designation
J12 Left V.35 Test Mode Indication:
J13 Left EIA-232-D Test Mode Indication:
J20 Left Alarm Monitoring (used with the –48 Vdc Central Office Power Unit):
State of
Jumper Strap
Table 3-2
Model 3616 DSU Jumper Straps
Left
— Enables V.35 Test Mode Indication (Pins 1 and 2).
This is the factory default. Right
— Disables V.35 Test Mode Indication (Pins 2 and 3).
Left
— Enables EIA-232-D Test Mode Indication (Pins 1 and 2).
This is the factory default. Right
— Disables EIA-232-D Test Mode Indication (Pins 2 and 3).
Left
— Disables the –48 Vdc alarm monitoring function
(Pins 1 and 2).
Right
— Enables the –48 Vdc alarm monitoring function (Pins 2 and 3); the NMS adapter cable is being used for alarm monitoring.
This is the factory default.
Function
J21 Right Alarm Monitoring (used with the –48 Vdc Central Office Power Unit):
Left
— Enables control of alarm monitoring via the NMS adapter cable (Pins 1 and 2); the NMS adapter cable is being used for alarm monitoring.
Right
— Disables control of alarm monitoring via the NMS adapter cable (Pins 2 and 3); a standard EIA-232 cable or the NMS adapter cable is being used for the diagnostic channel.
This is the factory
default.
3-4 December 1996 3615-A2-GB20-20
Page 37
Installing the Model 3616 DualFlow DSU
Installing the DSU
Prior
to installing the Model install a rear connector plate onto the rear of the COMSPHERE 3000 Series Carrier (Figure 3-2). Only after this procedure can the DSU be installed or de-installed by simply removing it from the carrier.
3616 DualFlow DSU,
. Procedure
1. At the rear of the carrier, set the tab on the rear connector plate into one of the slotted grooves on the carrier’ Make sure the rear connector plate uses the same slot position intended for the DSU.
s backplane. Loosely fasten the screws.
2. Loosely fasten the screw attached to the rear connector plate, allowing for slight adjustment that may be needed when installing the DSU.
3.
Change any default hardware strap settings that may be required before installing the DSU.
Figure 3-2.
COMSPHERE 3000 Series Carrier
, Rear V
iew
3-53615-A2-GB20-20 December 1996
Page 38
COMSPHERE DualFlow Data Service Units
4. Using a Phillips screwdriver
, loosen the screw holding the circuit pack lock and rotate the lock to the open position (Figure 3-3). Open the latch.
5. At the front of the carrier, hold the DSU vertically with the latch on its faceplate in the open position. Then, insert the circuit card into the top and bottom circuit card guides for the slot that contains the rear connector plate.
Slide the DSU into the slot, aligning the circuit card with the rear connector plate until the connectors seat firmly into the back of the carrier. Press the faceplate latch to secure the DSU into the carrier, rotate the circuit pack lock into the closed position (Figure 3-3), and tighten the screw.
6. Return to the rear of the carrier and tighten the rear connector plate screw.
Figure 3-3. Model 3616 DSU Installation and Circuit Pack Lock
3-6 December 1996 3615-A2-GB20-20
Page 39
Installing the Model 3616 DualFlow DSU
7. At the rear of the carrier, connect the appropriate router cable (EIA-232-D or V.35) to the rear connector plate. For an EIA-232-D interface cable, connect the EIA-232-D cable to the top DTE connector on the rear connector plate.
For the 25-pin V.35 interface, a V.35 Interconnect Cable is shipped with the unit.
Interface Cable to the 25-pin V
To connect a V.35
.35 connector
, refer
to Figure 3-4 and perform the following steps:
s V
a. Connect the 25-pin end of the DSU’
.35 Interconnect Cable to the bottom DTE connector of the rear connector plate. Tighten the screws on each side of the connector
b. Connect the 34-pin end of the DSU’
s V
.
.35 Interconnect Cable to the V.35 interface cable, then tighten the screws on each side of this connector.
8.
The installed DSU is connected to the DDS network through the 50-pin connectors at the rear of the carrier. These interfaces are specified in the USOC RJ48T, and the pin assignments are shown in Appendix D. Proper network connection to the DDS facility or to the network channel­terminating equipment must be made at the far end of the cable.
9. If the network line and remote DSU are installed and tested, do a Remote Loopback – a T
est Pattern
test.
10. If the Front Panel
test switch strap is to be disabled, slide the DSU slightly out of the carrier, open switch S3-1, then reseat the DSU into the carrier.
Do this now
.
11. Circuit ID information can be written on the cover plate under the appropriate slot number.
Figure 3-4. V.35 Interconnect Cable Installation
3-73615-A2-GB20-20 December 1996
Page 40
COMSPHERE DualFlow Data Service Units
Power-Up Routine
When power is applied, the DSU:
Runs a Device T
During the tests, all indicators on the DCP light briefly and the message the liquid crystal display (LCD).
Displays the results of each test momentarily as
Pass, Fail, or Abrt. (Abrt indicates that the Device
est was aborted because a network loopback was
T in pr
ogr
ess during the power
tests take about 20 seconds to complete.
If the DSU or DBM fails this test, follow the procedure below. Refer to Appendix A as you perform the procedures described in this guide. Refer to Chapters 4 and 5 for additional examples and procedures.
est on itself and the DBM.
Power-Up Tests
-up procedure.) These
appears on
. Procedure
1.
Press the Select
2. Press the
3. (Configuration) branch into view.
key to return to the top-level menu.
Local (F1 key).
key to scroll the Confg
Press the F1 key to
7. configuration.
Save to
The
8. Save the selected configuration to Activ (F1 key). Press the
9. then select
10. Select the Test branch (F3).
The Run T
11.
Select the device that Failed, the DSU or DBM.
12. Press the F2 key to run the Device T The device should pass.
13. Should the device fail, contact your service representatiave. (see Chapter 1).
screen is displayed.
Local
est on
SAVE
the selected
key to return to the top-level menu,
again.
screen appears.
est again.
Connecting to the Network
Network connections are provided through the 3000 Series Carrier. Refer to Figure 3-2 as you read the following sections and set up your network connections.
4. Press the function key directly under Confg.
Press the F1 key to select
5. Options).
Load from screen appears.
The
6.
Press the configurations into view appropriate configuration.
SyBC (Synchronous Backup for a Control
DSU) for a control when the router controls backup.
SyBT (Synchronous Backup for a Tributary
DSU) for a tributary when the router controls backup.
DiDg (Dial Diagnostics) for asynchronous
router-management data to be sent over the EIA-232 port via the DBM connection and user data over the V.35 port via the DDS connection.
key to bring the factory-loaded unit
Opts (Configuration
, and select the
Connecting to the NMS
A Model 3616 DualFlow DSU is set up for network diagnostic connection through the shared diagnostic unit (SDU), which is installed in Slot 0 of the carrier. Refer to
COMSPHERE 3000 Series Carrier
the
Manual
guide. For pin assignments, see Appendix D.
to set up the network diagnostic connection.
For connection of the DSU, see Appendix E of this
, Installation
Connecting to the Dial (or PSTN) or Switched 56 kbps Network
Connection to the dial network (or public switched telephone network – PSTN) or Switched 56 kbps network for the carrier-mounted Model 3616 DSU is through a network interface module (NIM) that is installed onto the carrier’s backplane (see Figure 3-2). Refer to the
COMSPHERE 3000 Series Carrier
for additional information or to install the NIM.
, Installation Manual
3-8 December 1996 3615-A2-GB20-20
Page 41
Installing the Model 3616 DualFlow DSU
Connecting to the DDS (or LADS) Network
NOTE
Before connecting the DSU to the DDS network, ensure that approved primary protectors have been installed on the circuit in accordance with Article 800 of the National Electric Code, NFPA 70, in the United States and Section 60 of the Canadian Electric Code, Part 1, in Canada.
If connecting the DSU to a LADS network there are distance limitations that govern the use of DSUs on the network. T limitations.
The DDS network interface is provided by two RJ48T 50-pin connectors on the back of the carrier (refer back to Figure 3-2, DDS Interface). Each connector serves eight contiguous slots in the carrier: one for Slots 1 through 8 and one for Slots 9 through 16.
Appendix E provides connectivity diagrams should you need further assistance in connecting the DSU to the network.
able 2-2 in Chapter 2 summarizes these
For the 25-pin V.35 connector Cable (feature number 3000-F1-510). This cable provides the interface between the 25-pin V.35 D-type connector and a V
need further assistance.
V.35 interface, and diagnostic or user data through its EIA-232-D/V preset configuration (SyBC, SyBT, or DiDg) selected in the Opts subbranch (Config branch).
.35 router cable.
Appendix E provides connectivity diagrams should you
The DualFlow DSU transmits user data through its
.24 interface. Cabling is based upon the
, use a V
.35 Interconnect
. Procedure
1. Install the V Step 8 of the Installing the DSU chapter.
2. Connect the plug end of the router’ the DSU’
ighten the two holding screws.
T
3. Connect the other end of the router’ the router’s primary serial port.
ighten any holding screws.
T
4. Connect the plug end of the router’s EIA-232 cable to the DSU’s EIA-232-D/V.24 connector.
ighten any holding screws.
T
5. Connect the other end of the router’s EIA-232 cable to the router:
.35 Interconnect Cable as described in
section of this
s V
.35 cable to
s V
.35 connector.
s V
.35 cable to
Connecting the DSU to a Router
The rear connector plate provides the router interface for the Model 3616 DSU. Each rear connector plate contains two DB25 (or 25-pin D-type) connectors. The top connector is an EIA-232-D/V.24 (ISO 2110) connector. The bottom connector is a CCITT V.35 (ISO 2593) connector.
If the DSU is to be configur
or SyBT configuration, connect to the router’s secondary serial port.
If the DSU is to be configur
configuration, connect to the router’ port.
ighten any holding screws.
T
ed using the SyBC
ed using the
s console
DiDg
3-93615-A2-GB20-20 December 1996
Page 42
COMSPHERE DualFlow Data Service Units
Addressing the Unit
A
unique address must be assigned to each control and tributary DSU in your network. Y within the range of 1 through 255.
NOTE
Do not assign the number 192 as a network address. This number is reserved as a broadcast address.
The
DBM requires a separate address, which is automatically assigned by the DSU. The address assigned a DBM is the DSU’ address is 1, the assigned DBM address will be 2).
The numbers 191 and 255 cannot be assigned to a DSU that has a DBM. However, addresses can be assigned in any order; they do not have to be sequential.
It is recommended that only
s address, plus 1 (e.g., if the DSU’s
NOTE
odd-numbered addresses
assigned to DSUs so that
even-numbered addresses
reserved for DBMs.
ou can assign an address
be
are
Tributary DSU Addressing
Tributary control DSU accesses its tributary via an active backup connection by specifying the tributary’
The 6700 or 6800 Series NMS accesses the DSU via its network address. To access a tributary DSU, first addresses the control, then the tributary issued from the NMS takes the format of control channel/control DBM network address/tributary network address. This is called link-level network addr
Figure 3-5 shows an example addressing, as well as link-level network addressing.
Refer to Chapter 4 to learn how to set the DSU’s network address.
DSU addresses are user
of DSU and DBM
-definable. The
s address.
the NMS
. An address
essing.
Figure 3-5. Addressing Example
3-10 December 1996 3615-A2-GB20-20
Page 43
Verifying Operation and Testing Connections
Perform verification testing after any installation.
After installing and configuring the circuit (including control and tributary DSUs, the DDS network, the DBMs and their dial connections), perform a series of tests from
the contr
the SDCP or NMS).
To Connect the SDCP to a DSU
ol DSU to verify network operation (using either
Installing the Model 3616 DualFlow DSU
second line
On the
Press the that the cursor is on.
Press the
Press the
one position to the left or right, to change either the carrier or slot number.
Press the F3 key to toggle between DSUs, to
switch from 1:01A to 1:02A in this example. (In our example, the previously accessed DSU was located in Slot 2 of Carrier 1.)
F1 key () to increment the number
F2 key () to decrement the number.
and
keys to move the cursor
For the carrier-mounted Model 3616 DSU, the SDCP must first be reconnected to the DSU. Once connected, the SDCP operates like a DCP
.
. Procedure
Press the
1. A screen similar to the following appears.
The cursor is usually positioned under the second position of the slot number (1:01 ).
In this example, the
1 indicates Carrier 1 (Carr)
01 indicates the DSU in Slot 1
A is reserved for future use
Select key (refer to Figure 3-2).
Carr:Slot: 1: 01 A
1:02A
F1 F2
first line
F3
shows
Press the
2. The SDCP accesses the DSU in Carrier 1, Slot 1.
The top-level menu (your starting point) of the carrier
From the that this is a carrier-mounted DSU (1:01A instead of Port1) that is located in Carrier 1, Slot 1, is operating as a DSU (i.e., not as a DBM), at
9.6 kbps, and is configured as a control (C). From the second line you can see that there are no
NMS messages (no waiting to be read and cleared.
Also note that the SDCP indicator on the selected DSU’
Select
key on the SDCP again.
-mounted DSU is displayed.
1:01A DSU 9.6 C Local Remot
F1
first line
s faceplate,
F2
of this example, you can see
Msg branch over the F3 key)
Front Panel
, is lit.
F3
3-113615-A2-GB20-20 December 1996
Page 44
COMSPHERE DualFlow Data Service Units
Verifying Network Addresses, the Network, and DBM Operation
Establish a backup connection and perform a Digital
est over the backup connection to ensure that the
T switched network is functioning. Access the DSU’ identity (ID) subbranch
for the tributary DSU
that the DSU is properly addressed.
Verify that no alarms appear in the Device Health and
Status subbranches. Refer to the Verifying Operation and
T
esting Connections
section of Chapter 2 for procedures
that lead you through each of these procedures.
s
to ensure
Other Tests
The
following lists the tests available on your DSU. Refer to the T test information, as well as more detail on how to configure and operate the DSU. Refer to Appendix A to determine how best to access each test.
Digital Loopback (DL)
Remote Digital Loopback (RL) – DBM only
Bilateral Loopback
Digital T
End-to-End Test (EE) – DBM only
est Branch
Device T
est (Devic) Local Loopback DTE Loopback
est
(DT) – DBM only
Bit Err Lamp T
or Rate T
est (Lamp)
section of Chapter 4 for further
(LL) – DSU only
(DTE)
est (BERT)
3-12 December 1996 3615-A2-GB20-20
Page 45

Operating the DSU

Overview 4-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DCP and SDCP Operation 4-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Keypad 4-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Menu Structure 4-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Top-Level Menu 4-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Status Branch 4-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Health and Status 4-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Device Health and Status 4-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Expanded Health and Status 4-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Subnetwork Health and Status 4-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTE Status 4-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Circuit Quality 4-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Identity 4-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Terminal Power 4-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Backup Branch 4-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dial Backup Operation 4-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring the Unit for Dial Backup 4-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Understanding Operating Modes 4-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual Backup 4-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Placing a Backup Call 4-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual Dial Backup Termination 4-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Branch 4-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Abort 4-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Device Test 4-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Loopback 4-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Local Loopback 4-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DTE Loopback 4-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Loopback 4-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Remote Digital Loopback 4-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bilateral Loopback 4-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Test 4-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
End-to-End Test 4-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bit Error Rate Test 4-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lamp Test 4-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration Branch 4-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Selecting an Application Configuration 4-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration Options 4-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Poll List 4-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Displaying the Poll List 4-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Changing the Poll List 4-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Acquiring the Poll List 4-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Directory 4-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Entering a Telephone Number 4-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Phone 4-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Network Address 4-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assigning an Address 4-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
4-13615-A2-GB20-20 December 1996
Page 46
COMSPHERE DualFlow Data Service Units
Control Branch 4-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmitter Control 4-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LEDs 4-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
External Leads 4-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Displaying External Leads 4-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Changing External Leads 4-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reporting External Lead Changes to NMS 4-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Message Branch 4-20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
A DualFlow DSU can be managed from its control panel, or from a COMSPHEREr 6700 or 6800 Series NMS. This chapter describes how to manage the DSU using the control panel. Refer to the appropriate NMS documentation to understand how to manage the unit from the NMS.
The DSU’ hierarchy, sometimes referred to as a menu tree. Refer to Appendix A as you perform the procedures described in this guide to help you quickly learn more about your DSU.
s menus are or
ganized as a branching
DCP and SDCP Operation
There are two types of control panels, one for each
DSU model.
The standalone Model 3615 DualFlow DSU (Figure 4-1) is controlled from its diagnostic control panel (DCP).
The carrier-mounted (nest- or rack-mounted) Model
3616 DualFlow DSU (Figure 4-2) is controlled from a shared diagnostic control panel (SDCP). The SDCP is mounted onto the COMSPHEREr 3000 Series Carrier to control multiple units.
NOTE
Throughout this guide, DCP refers to either control panel,
DCP
or
SDCP
, except where a
distinction is made.
KEYPAD
LCD
DISPLAY
COMSPHERE 3615
NETWORK/DEVICE
ALARM
F1 F2
Alrm
OK
TEST
MODE
Dial TXD RXD RTS DSR
103
DTE STATUS INDICATORS
DIAL
BACKUP
F3
CTSTest
104
105
DTR
LSD
108
107
106
109
496-14469-01
Figure 4-1. Model 3615 DCP
4-2 December 1996 3615-A2-GB20-20
Page 47
Operating the DSU
CARRIER SLOTS 1–16
SDU12345678910111213141516
Select
OK Alarm BckUp Test EC
F1 F2 F3
COMSPHERE 3000
SELECT
KEY
INDICATORS
OK Alarm BckUp Test EC
NETWORK
DEVICE
ALARM
DIAL
BACKUP
STATUS
TEST
MODE
ERROR
CORRECTION
KEYPAD
Status
OK Alrm Test Dial
103
TXD
104
RXD
105
RTS
106
CTS
107
DSR
108
DTR
109
LSD
Front Panel
Multirate
DSU
3616
LCD DISPLAY
NETWORK/ DEVICE ALARM
TEST MODE DIAL BACKUP
DTE STATUS INDICATORS
SDCP INDICATOR
496-14470-01
Figure 4-2. SDCP and Model 3616 DSU Faceplate
Both control panels have a 2-line, 16-character liquid crystal display (LCD) and a keypad, through which you can
Monitor the unit’
s health and status
Initiate dial backup
Initiate diagnostic tests
Load or change the unit’s configuration, or how it
will operate Display or change the status of the general purpose
external DTE leads.
The DCP’
s LCD displays the result of any command
initiated from the DCP.
Refer to Appendix C to understand the meaning of
DCP status indicators.
4-33615-A2-GB20-20 December 1996
Page 48
COMSPHERE DualFlow Data Service Units
Keypad
There are seven keys on the DCP of the standalone Model 3615, and eight on the SDCP for the carrier­mounted Model 3616 DSU. The additional key, the Select
, connects the SDCP to a specific DSU located in a
key specific carrier and slot within the carrier.
F1 F2
The key returns you to the top-level menu, and
terminates any work in progress.
The
key returns you to the previous display, one level up from the current display used to terminate a data entry display without making a change.
The
and
keys scroll menus or other
displays to the left or right, respectively.
On status and test r
esult displays
keys scroll additional information into view.
F3
. It can also be
, the
and
Top-Level Menu
The top-level menu is the
operations. Y
ou can always return to this point from anywhere in the menu by pressing the this key immediately terminates any operation or work in progress. Refer to
Appendix A as you read about the
branches and subbranches.
The standalone Model 3615 DualFlow DSU indicates whether the DDS or DBM line interface is being monitored. The carrier-mounted Model 3616 DualFlow DSU displays the DSU’ cabinet.
When there are simultaneous DSU (V.35) and Dial (232) connections (e.g., as in a Dial Diagnostic – DiDg configuration), the top-level screen toggles between two displays every 10 seconds, displaying the status of each of the two ports, the EIA-232-D port for the router management or user data and the V.35 port for the user data.
232 DBM 9.6 C Local Remot
F1
starting point
for all DSU
key
. Pressing
s carrier and slot location in the
F2
F3
On data entry displays
, these keys move the cursor one character to the left or right to allow entry of one digit or character at a time.
Function keys (F1, F2, or F3
displayed directly above the key
Additional information on operating the DSU’
) select the item
.
s keypad can be found in the procedures used to install and verify operation of the DSU in Chapters 2 and 3, the procedure for editing configuration options in Chapter 5, and the various procedures scattered throughout this chapter.
Menu Structure
The menu is your map through the DSU’ functions. The following sections describe each branch and subbranch, and provide procedures for operating certain features. Appendix A and describes the DSU’
menu is also included on the Refer with this guide
.)
shows the complete menu
s branches and subbranches. (
ence Car
s various
The
d that comes
V.35 DSU 56 C Local Remot
F1
F2
F3
Status Branch
The Status (Stat) branch reports on the health and
status of the DSU, DBM, the DTE interfaces, the quality of the dial connection, the identity of the DSU (model number, serial number, etc.), and the terminal’ (where it checks the presence of voltage on the DTE’s RTS lead).
s power
4-4 December 1996 3615-A2-GB20-20
Page 49
Operating the DSU
Health and Status
The Health and Status (H/S health and status of the DSU, as well as the DBM. It automatically scans for DSU and line conditions that are not within normal limits.
There are three types of Health and Status messages:
Devic (Device Health and Status)
Expan (Expanded Health and Status)
Subn (Subnetwork Health and Status)
All alarm and status conditions are displayed for the specified DSU at the time the option is selected.
local DSU
every 2 seconds; conditions are not updated.
messages.
, the alarm and status conditions are updated
for a r
Refer to Appendix C for a complete listing of these
) subbranch displays the
emote DSU
, the alarm and status
For a
Device Health and Status
Device Health and Status (Devic) reports health and status information for a selected DSU. If five minutes
elapse without a key being pr
Status screen is redisplayed.
When the digital circuit is the active link,
— The
— The
An asterisk ( NMS activity
first line
normal-operation timer (hh:mm:ss).
second line
rate and can also display one or more of the test or alarm messages.
* ) appears at the far right to indicate .
essed
, the Device Health and
displays a running
displays the DSU’
s operating
If the right arrow () appears to the right of Expanded
H/S
, there is more than one message. Press the
see the next message.
key to
Subnetwork Health and Status
Subnetwork Health and Status (Subn
information from a DSU’ DBMs assigned to that DSU’ downstream network addresses and current statuses are listed. To page through tributary addresses:
Press the
address. Press the
address.
No PList appears if no DSUs are being monitored
downstream.
This status information is only available through the local branch and only when DBM NonD.
F1 key () for the
F2 key () for the
s subnetwork (all DSUs and
s active poll list). The
) displays status
next highest
next lowest
Diag Type
is set to
network
network
DTE Status
The DTE of the local or remote unit’s external DTE interface.
The DTE interface statuses are displayed in sets. Use the or view.
status subbranch provides a snapshot status
For the local DSU status
and updated every 2 seconds.
For the r
returned based upon a monitoring period of approximately 3 seconds.
emote DSU status, only one set of states is
key to scroll each set of lead statuses into
, the display is sampled
A right arrow (
if there is more than one message. Press the key to see the next message.
) appears just before the asterisk
Expanded Health and Status
Expanded Health and Status (Expan) only appears
during automatic dialing, and only if an expanded health and status message has been generated. It retrieves Health and Status information for the local DSU after an automatic backup or DTR-controlled backup attempt has failed, or when there is a disconnect after a successful connection.
If both a backup connection and the DDS line are active a selection screen appears first.
Select
V.35 to monitor the V.35 interface (for user
data). Select
232 to monitor the EIA-232-D interface (for
router-management or user data).
4-53615-A2-GB20-20 December 1996
Page 50
COMSPHERE DualFlow Data Service Units
Circuit Quality
Circuit Quality (CircQ) shows the level and quality of
the signal being received from the network by the DBM.
This subbranch is only available for a V
.32 DBM.
. Procedure
Press the
1.
2. Press the function key (F1, F2, or F3) directly
below the selection. One field at a time is displayed.
Identity
Identity (ID) displays a listing of the DSU’
serial numbers, the equipment installed (DBM), software/ firmware versions, the network address, the DDS or
s rate, and the DBM’s rate.
DSU’
s model and
the DSU and its equipment.
Press the
3. display (screen) at a time.
Table 4-1 lists the Identity information provided about
Table 4-1
Identity Descriptions
Description Information Displayed
Model: 3615 S#: Unit serial number. DSU SW ver: Software/firmware version residing on the DSU. Netwrk Addr: Unit’s network address.
or 3616.
key to scroll ID into view.
key to display the information, one
DSU Rate: Value set for DSU
does not appear if a DBM has its DBM
DBM SW ver: (
Switched 56 DBM only
DBM Rate: Value set for DBM DBMtype:
App Modul: ASPEN. Appears when the Single-Port Async/Sync feature is installed. App Modul: CISC or 64CC.
xxx yy.y z
)
Software/firmware version residing on the Switched 56 DBM.
Type of DBM installed:
xxx
can be either
V (V.32 DBM), 4wS (4-wire Switched 56 DBM), or 2wS (2-wire Switched 56 DBM).
yy.y
indicates the DBM’s maximum speed.
z
designates whether the DBM Primary Core option was enabled. (A P indicates Primary Core is enabled.)
Only appears when a DBM is installed.
CISC when the Clear Channel with Integrated Secondary Channel chip is present. 64CC when the CISC chip is not present.
Rate(Kbps)
Rate(Kbps)
configuration option; the DSU’s aggregate speed. This
Primary Core
configuration option; the DBM’s aggregate speed.
configuration option set to Yes.
4-6 December 1996 3615-A2-GB20-20
Page 51
Operating the DSU
Terminal Power
Terminal Power (TPwr
EIA-232 or V.35 interface (connector). The DSU checks the state of the R ON to report the following:
When the voltage is approximately less than –3V or
greater than +3V for both the EIA-232 and V.35 interfaces.
— If power is detected, the
TS lead to determine when the DTE is
On. If no power is detected, the second line displays
Off.
) displays the status of the
second line displays
Backup Branch
The
Backup ( operation. The following sections explain dial backup operation.
Dial Backup Operation
The DualFlow DSU with dial backup capability can provide backup for a point-to-point circuit operating at 56 kbps or below DualFlow configurations.
Backup is controlled primarily by software configuration options in the DBM, DBM Port, option sets. The unit can be configured so that backup can be either automatic or manual. Manual backup can be controlled from either the DSU’s control panel, or a 6700 or 6800 Series NMS.
Backup begins with configuring the unit.
Configuring the Unit for Dial Backup
The following configuration options should be set, whether initiating backup manually or automatically.
DBM Option Set
AutoAnswer – Select Enab.
When enabled, this option set allows the DBM to answer an incoming call. (Enab is the factory­loaded default setting.)
Bckup) branch controls dial backup
. Appendix E shows some typical
and
:
Backup
Call Setup
If the control DSU is to initiate the call
control for Pswrd and the tributary for Cllbk. If the tributary DSU is to initiate the call,
control for Cllbk and the tributary for Pswrd.
Backup Option Set
for manual backup):
Auto Bckup – Select Enab.
When enabled, the DSU will automatically initiate dial backup when the DDS line is down. Up to 10 attempts will be made.
If both the control and tributary DSUs are configured for automatic backup, NtwkTimOut should be set to and tributary DSUs do not try to place a call at the same time.
On a point-to-point circuit, it is best that only one end performs automatic backup. It is possible to trigger the backup for single-direction network failures only detected at the remote DSU. The remote DSU must have RTS Control set to FrcOn.
– Set call setup security level:
None
– No call setup security is required.
(None is the default.)
Password
exchange passwords before the DBMs can complete the connection. There must be an incoming password (RxPwd) and an outgoing password (TxPwd) set up. Select Pswrd when the DiDg application configuration is being used.
Callback
passwords and a Backup Directory pointer must be sent before a call can be initiated. There must be an incoming password (RxPwd) and an outgoing password (TxPwd) set up, and the originator’s local telephone number (Phone subbranch) must be stored in the answering DBM’
Alarm
control DBM, and the DBM only answers incoming calls when there is a facility alarm.
– Originating and receiving DBMs
– Both DBMs must exchange
s Backup Directory – No security is to be used at the
(none of these need to be set
different
.
, set the
values so that the control
set the
4-73615-A2-GB20-20 December 1996
Page 52
COMSPHERE DualFlow Data Service Units
NOTE
Auto Backup
and
Auto Restor
should not be enabled if
DTRCallCon
is enabled (set to
Orig or Ansr).
Bckup
Dir
– Select the call directory identifier
(1 to 10) stored in the DBM’s Backup Directory for the telephone number to be dialed.
AutoRestor – Select Enab.
When enabled, the DBM automatically restores data to the DDS circuit when service is restored and the amount of time set in RestoreTimOut
has
expired.
NtwkTimOut – Set the amount of time that the
DDS circuit must be out of service before a backup attempt is made:
from 0:00 (minutes:seconds) to
29:59 (the default is 0:20).
RestorTimOut – Set the amount of time that the
DDS circuit must be back in service before automatic restoration is attempted: from 1 to 60 minutes (the default is 5 minutes).
MultiCall – Select Disab.
When enabled, instead of following the normal calling cycle, the DBM cycles through all dial strings contained in its Backup Directory until a call attempt is successful.
Do not enable MultiCall unless more than one telephone number is in the Backup Directory and each successive (i.e., 1, 2, 3, etc.) telephone number is different from the previous entry. Directory entries should be unique.
Understanding Operating Modes
The Backup branch controls operation of the Dial Backup function. The DualFlow DBM has three modes of operation:
In Idle mode, there is no dialed connection. The
DDS circuit is active and carrying user data.
In Standby mode
to another DBM or compatible dial backup unit, but has not connected line data to the DBM’
In Dial Backup mode
and carrying user data and diagnostics.
, the unit has a dialed connection
s DTE port.
, the dialed circuit is active
TriesTimeOut – Specify the overall time limit
during which a DBM attempts to establish a dial backup call when
Auto Bckup
is enabled or when raising DTR initiates a call attempt: from 1 to 60 minutes (the default is 15 minutes).
Backup Branch Menu Selections
Current
Backup Mode
Idle Bkup
Standby Disc
Dial Backup DrBU
Backup
Command
Dial
Cnnct
StnBy
Dial out, establish, and switch to dialed link (Dial Backup mode). Dial out and establish dialed link (Standby mode).
Disconnect dialed link (Idle mode). Connect the DBM line data to DBM’s DTE port (Dial Backup mode).
Disconnect dialed link and switch to private line (Idle mode). Disconnect the DBM line data from DBM’s DTE port (Standby mode).
explains the ef
Table 4-2
T
able 4-2 lists the Backup branch operating modes and
fects of each backup command.
Effect
4-8 December 1996 3615-A2-GB20-20
Page 53
Operating the DSU
Manual Backup
You can control each step of a backup attempt by
following one of these procedures.
Placing a Backup Call
To
place a backup call:
. Procedure
1. Go to the Bkup option set under the Confg branch and set
2.
Select telephone number from the Backup Directory.
Select
3. identifying the Backup Directory indicator.
If the telephone number in the Backup Dir the number you want to dial, go to Step 5.
4. Select another telephone number to call:
Press the F1 key () to increment the directory
Auto Bckup
Bckup
Dial, the
indicator (e.g., 1 to 2).
to Disab.
(Backup branch) to select a
Backup Dir
screen is displayed
ectory is
Abort
The Abort
running.
in pr
ogr
There are two types of selections to abort a test:
Selective
Subn (Subnetwork) only displays for the DBM
After selecting either Selective or Subn, the test is terminated and the DCP displays the message Complete.
selection allows you to abort a test that is
The DSU cannot run any other test until the test
ess is aborted.
terminates whatever test is in progress at
the local DSU.
branch. This selection terminates all tests running on the remote DSU or DBM.
Command
Device Test
The Device (Devic) T built into the DSU. When testing the DBM, the DBM must
be in Idle mode, with no call in progr Device T
est.
est uses a test pattern generator
ess befor
e running a
Press the F2 key () to decrement the indicator
(e.g., 2 to 1).
Select
Dial
5.
6.
Once the dialed call has been established, select
Cnnct
(F2); the DBM places the call.
to switch data to the dialed connection.
Manual Dial Backup Termination
If
in Standby mode, select
If in Dial Backup mode, select
Disc.
DrBU.
Test Branch
The Test
for the DSU, the DDS circuit, the DBM, and the backup circuit. Most tests can be run simultaneously on the DSU and DBM. When the tributary DSU receives a test request from the control DSU, it aborts any locally initiated test in progress.
Running a test can af cause your application session to be dropped depending upon front-end processor, time-out parameters, etc. since no data or acknowledgment messages will be transmitted while the test is in progress.
branch provides extensive testing capabilities
fect your application data or may
NOTE
On power-up, the DSU sends out polls to verify that a DBM is installed. It then initiates a Device Test on itself and the DBM. The results of the tests appear momentarily on the DCP’s LCD.
Loopback
The Loopback (Lpbk) branch displays four loopbacks:
Local Loopback (LL) – DSU only
DTE Loopback (DTE)
Digital Loopback (DL)
Remote Digital Loopback (RL) – DBM only
Figure 4-3 shows where each loopback occurs on the
circuit. Refer to the figure as you read about loopbacks.
4-93615-A2-GB20-20 December 1996
Page 54
COMSPHERE DualFlow Data Service Units
NOTE
To abort a loopback on the tributary DSU from the NMS, establish a dial connection with the control DSU, then issue a subnetwork abort command from the NMS to the control.
Local Loopback
Only available to a DSU, Local Loopback (LL) is session-disruptive; that is, performing the test will disrupt data. It permits the DTE or router to run a test to determine whether the DTE or router connection to the DSU and the DSU itself are functioning properly. The DSU must be connected to the DTE or router, but the network connection to the DSU is not required.
While the DSU is in Local Loopback, any data transmission by the DTE or router is returned as received data. An operator can send a test pattern and verify correct reception of the test. The DSU does not monitor this testing.
NOTE
If the NMS is to abort the Local Loopback, the tributary’s DBM must be in Standby mode. If in Dial Backup mode and the NMS issues the command will not be recognized. The loopback will have to be aborted from the DSU’s control panel.
Abort
command, the
DTE Loopback
DTE Loopback (DTE
DTE interface without affecting operation of the other port. This loopback is used to verify that the DTE or router connection and the cable are good.
) loops back the data path at the
Digital Loopback
Digital Loopback (DL) allows manual testing of the
remote end of the circuit. Data coming in is immediately transmitted back. For example, a Digital Loopback may be required in order to complete an external bit error rate test (BER
T) from the remote DSU. The local DSU receives test data, loops it back to the transmitter before the DSU’s DTE interface, and returns it to the network.
Digital Loopback can also be initiated by receiving a V.54 pattern to go into Digital Loopback. Enable configuration options V.54 Lpbk (V.54 Loopback) in the DSU option set, and
RespondRDL
(Respond to Remote
Digital Loopback).
Remote Digital Loopback
Only
available to the DBM, the Remote Digital
Loopback (RL), sometimes referred to as RDL, typically supports testing using an external device, like a protocol analyzer that is connected to the local DSU’s DTE interface. A test message from the external device is looped back from the receiver to the transmitter in the remote DBM and returned to the local DBM.
In Remote Digital Loopback, the local DBM (control or tributary) puts the remote DBM into Digital Loopback.
DTE
(ROUTER)
DTE
DL or
RL on
LL
DSU
COMSPHERE 3610
NETWORK
Aggregate
DSU
COMSPHERE 3610
DL or
RL on a
Port
DTE
(ROUTER)
496-14493a
Figure 4-3. Loopbacks
4-10 December 1996 3615-A2-GB20-20
Page 55
Operating the DSU
When a DBM (control or tributary) originates Remote
Digital Loopback, both the originating DBM and the
geted DBM enter Test mode. No other test can be run at
tar the originating DSU or the tar
geted DSU until the Remote
Digital Loopback is aborted.
The DBM does not generate test results.
NOTE
To activate a V.54 Loopback from the NMS to a DSU, first enable
V.54 Lpbk
(DSU option set) at both the control and tributary DSUs. Then, select 3600 remote-digital at the NMS,
not
V.54-remote-digital.
Bilateral Loopback
Bilateral Loopback (Bilat Lpbk) is a combination of DTE and Digital Loopbacks operating simultaneously in the same DSU. Both Bilateral and Digital Loopbacks are selected from the DSUpt (DSU Port) or DBMpt Port) option set.
(DBM
During the test, the TXD, RXD, and R
TS LED indicators show the states of the leads at the DTE interface if the DBM port leads are being displayed. At the conclusion of the test, the local DSU releases the remote DBM from Digital Loopback.
T
o review the results of the test, select
and press the
key to scroll through the results shown
Displ (Display)
in Table 4-3.
When the test is over
instead of
Active.
, the top line displays
Final
Table 4-3
Digital Test Results
Results Information Displayed
Time: Running test timer. (The Clr
selection resets the timer to 0:00:00.)
Tot Error: Running count of bits in error;
Max, if the maximum error count has been reached, the maximum being 64000. (The Clr selection resets the counter to 0.)
Err Secs: Running count of errored
seconds. (The Clr selection resets the counter to 0.)
NOTE
If
Bilat Lpbk
is enabled, requesting a Remote Digital Loopback or Digital Test will automatically initiate a DTE Loopback, as well.
Digital Test
Only
available to a DBM, the Digital T the functionality of a pair of DBMs. This test is run on the DBM over the backup connection to a remote DBM for point-to-point testing.
The remote DBM is placed in Digital Loopback, then
the local DBM transmits the 51
1-bit test pattern over the network to the remote DBM for an operator-specified length of time.
est (DT) checks
End-to-End Test
Only available to the DBM, the End-to-End (EE) Test
analyzes a control and a tributary DBM, and the network circuit between them
in both dir
transmits fixed packets (or blocks) of data between the DBMs When an End-to-End T may be disrupted.
o view the results of the test, select
T
and press the
key to scroll through the results shown
in Table 4-4.
When the test is over
, the top line displays
instead of Active.
ections independently
. It
est is run, diagnostic data
Displ (Display)
Final
4-113615-A2-GB20-20 December 1996
Page 56
COMSPHERE DualFlow Data Service Units
Table 4-4
End-to-End Test Results
Results Reported By
Time: Local and remote DBM Running test timer. (The Clr selection resets the timer to 0:00:00.) Tot Block: Local and remote DBM Number of blocks completed. (The Clr selection resets the counter to 0.) Rx Blk err: Local and remote DBM Number of incoming blocks with errors detected, indicating a fault in the
Tx Blk err: Local and remote DBM Number of blocks with errors detected at the remote DSU, indicating a
Rx TimOuts: Local DBM only Number of blocks that were not received or acknowledged by the
1
Local
refers to the test initiator.
1
incoming transmission path. (The Clr selection resets the counter to 0.)
fault in the outgoing transmission path. (The Clr selection resets the counter to 0.)
remote DSU or DBM. (The Clr selection resets the counter to 0.)
Information Displayed
Bit Error Rate Test
The Bit Error Rate T disruptive test that transmits a 51 the network circuit. It can monitor the results by putting the remote DSU or DBM into Digital Loopback and checking the returned pattern for errors, or by simultaneously executing a BER
The test continues until aborted fr
If nondisruptive diagnostics are in effect (if Diag Type is set to NonD), diagnostic data can be disrupted.
T
o display the r
Displ. The results are shown in Table 4-5. T results of the test and clear the counters to zero, press F3
to select
Clr.
est (
BERT
) is a session-
1-bit pattern. It analyzes
T in the local DSU.
om the DCP or NMS.
esults
of the test, press F2 to select
o clear the
Table 4-5
Bit Error Rate Test Results
Results Information Displayed
Time: Running test timer. (The Clr
selection resets the timer to 0:00:00.)
Tot Error: Running count of bits in
error; Max, if the maximum error count has been reached, which is 64000. (The Clr selection resets the counter to 0.)
Err Secs: Running count of errored
seconds. Errored second is at least one error is detected during a 1-second time period. (The Clr selection resets the counter to
0.)
4-12 December 1996 3615-A2-GB20-20
Page 57
Operating the DSU
Lamp Test
The Lamp T (LEDs) and liquid crystal display (LCD) on the DSU’s control panel (both models). Any indicator that does not flash is not functional.
Note that if all LEDs are functioning, all the indicators on the Model 3615 DCP are flashing steadily COMSPHERE 3000 Series Carrier, the indicators on the SDCP remain ON. The LCD on the DCP or SDCP alternately flashes solid blocks, moving from position to position on the display until the test is aborted.
Pr
essing any key
portion of the Lamp Test and return you to the DSU Test menu so you can abort the test. Once aborted, the LCD and LEDs stop flashing.
est is a local test of the status indicators
. In a
except
the key will stop the LCD
Configuration Branch
The Configuration (Confg) branch allows you to configure or customize the DSU and its DBM to fit your
s requirements, to enter and change telephone
site’ numbers, and to specify the mode for viewing or editing configuration options.
Synchronous Backup for a Tributary DualFlow
DSU (SyBT) – Sends user data over the DDS connection via the V DBM for synchronous user Bandwidth on Demand or backup situations. This configuration also configures the DualFlow DSU to answer calls only when DTR on the EIA-232 port is active, and to disconnect when DTR transitions from active to inactive (DTRCallCon: Ansr). Used for a tributary device.
Dial Diagnostics (
DDS connection via the V.35 port, and configures the DBM for asynchronous router-management data and for disruptive diagnostics.
Select the appropriate configuration based upon how the unit will be used within your network. All configurations support simultaneous DDS and DBM connections. The dif connection is used.
Refer to the Application Configurations in Appendix E for examples using these three configurations. Refer to the
s menu in Appendix A as you follow these steps.
DSU’
.35 port, and configures the
-data transfer during
DiDg) – Sends user data over the
ference is in how the DBM
. Procedure
1.
Select
Confg (Configuration branch).
Selecting an Application Configuration
The DSU is shipped from the factory with three common applications already configured. All you have to do is select the appropriate application and load the preset configuration into the unit. These configurations include:
Synchronous Backup for a Control DualFlow DSU
(SyBC) – Sends user data over the DDS connection via the V synchronous user on Demand or backup situations. This configuration also configures the DualFlow DSU to dial when DTR on the EIA-232 port transitions from inactive to active, and to disconnect when DTR transitions from active to inactive (DTRCallCon: Orig). Used for a control device.
.35 port, and configures the DBM for
-data transfer during Bandwidth
Press the F1 key to select
2. Options subbranch).
Load from screen appears.
The
3.
Press the configuration into view.
By referencing the menu in Appendix A, you will see that pressing the key is often more efficient.
4. Make your selection: press the function key (F1, F2, or F3) directly below the desired configuration.
The Edit/Save
or key to scroll the desired
NOTE
screen appears.
Opts (Configuration
SyBC, SyBT
, or DiDg, and
4-133615-A2-GB20-20 December 1996
Page 58
COMSPHERE DualFlow Data Service Units
To view the configuration loaded:
. Procedure
1.
Select an
2. Press the F1 key (Next) to scroll through each
configuration option’s default (factory-loaded) setting.
The option sets (DSU, DSU Port, DBM, etc.) scroll from the last to the first (e.g., Diag BkupSAVEDSUDSU Port, etc.).
Select
3. then select it).
Press the
4. screen.
ou can select another option set to view
Y can proceed.
Refer to Chapter 5, example showing you how to edit (change) configuration options.
Select
5.
option set (e.g., DSU – F2 key).
Prev
(press the
key to return to the Edit/Save
Save (F1).
key to display Prev,
Configuring the Unit
, or you
, for an
Poll List
The Poll List (PList
the DBM’ the tributary DSU and DBM one level downstream, and only a control can acquire a poll list.
you select network addresses are erased from the DBM’
to a control DBM configured for nondisruptive diagnostics (
s poll list. A control DBM’
ou can display
Y
Clr (Clear) from the Poll List
PList is
only available from the Local branch,
Diag Type
) subbranch maintains or changes
s poll list includes
, clear, change, or acquire a poll list. If
screen, all
s poll list.
and only
is set to NonD).
Displaying the Poll List
To
display each of the network addresses included in
the DSU’
s poll list:
. Procedure
Select
1.
2.
PList (F2).
Select
Displ (F1). The following screen appears:
Save to
The
6. Select Activ (F1). The selected application’
to the DSU’
Command Complete
screen appears.
s configuration is saved
s Active operating area, and the
message appears.
Configuration Options
The Configuration Options (Opts
you to save, copy
Refer to Chapter 5, fully explains the Opts example of changing configuration options.
, and/or change configuration options.
Configuring the Unit
subbranch, and provides an
) subbranch allows
. Chapter 5
Addr: 2 Acti ve
F1
The number after Addr (in this example, 2) is the network address of the poll list member. The member is identified as either Active or Skip (identified via the Change Poll List function).
Press the
3. addresses.
Press the
4.
F1 or F2
key to return to the Poll List
F2
key to display additional
F3
screen.
4-14 December 1996 3615-A2-GB20-20
Page 59
Operating the DSU
Changing the Poll List
To change the poll list (e.g., add network address 3):
. Procedure
Select
1.
2.
3.
Chang (F3).
Select
Activ (F1).
Press the
Poll List:
Displ Clr Chang
F1
Chng
Activ Delet Skip
F1
F2
P
oll List:
F2
F3
F3
F1 key to increment network address 2.
To delete a network address (e.g., 3) from the poll list:
. Procedure
1.
Select
Delet (F2).
Chng
P
oll List:
F2
F2
F3
Enter
F3
Activ Delet Skip
F1
2. Select
Enter
(F3).
Address: 3
F1
In this example, 3 was just added, so it is the address displayed. If another address needs to be deleted, change the network address displayed as previously shown.
Address: 2
Enter
F3
4.
Select
F1
Enter (F3).
F2
Address: 3
Enter
F1
F2
F3
The address is added to the poll list. The control determines the round trip delay
, then sends that
information to the tributary DSU. Press the
5.
key to return to the Chng Poll List
screen.
Make 3 Acti ve: Command Complete
The tributary DSU associated with the address is removed from the poll list.
D el 3 frPList:
F2
F3
Command Complete
F1
F1
F2
F3
4-153615-A2-GB20-20 December 1996
Page 60
COMSPHERE DualFlow Data Service Units
Acquiring the Poll List
A
call must be established before this procedure can be performed (refer to the Backup Branch section earlier in this chapter).
To automatically generate a poll list if a control:
. Procedure
Press the
1.
2.
Select
ou can stop the process and keep the poll list as it
Y has been generated by selecting
key to display
Poll List: Displ Clr Chang
F1
F2
Acq (F1).
Poll List: Acq Displ Clr
F1
Acquir
F2
P
Abort
F1
F2
Acq.
F3
Abort.
F3
oll List:
F3
Directory
The DSU’s dial backup Directory (Dir) can store up to
ten telephone numbers (dial strings) so the DBM can call other DBMs. Directory entries are numbered from 1 to 10. Each dial string in the directory can be up to 36 characters in length. Refer to Table 4-6 for numbers and characters that can be used.
When the dial string or changes are complete, enter an underscore ( _ ) to the immediate right of the last character;
this ends the dial string field
Table 4-6
Directory Entry and Password Characters
Character
0—9 Dialing digit (These are the only
, (comma) In a dial string: a 2-second pause
( ) (space) Space (readability character)
1
characters accepted by the Switched 56 DBM.)
* # Tone-dialing character#
t T p Pulse dial w W
ť Delimiter, separating telephone
Tone-dialing character*
one dia
l
ait for dial tone
number and callback directory pointer (for use with callback security)
at the beginning of a password; suppresses display of all following characters (invisible mode)
.
Use
2
2
2
3
Acquir Command Complete
F1
P
oll List:
F2
F3
_ (underscore) Required character for
end-of-string marker (erases end-of-line)
1
The colon (:) character should not be entered from the NMS.
2
Not supported by Switched 56 DBMs.
3
Space is not used for directory entries.
Otherwise, all tributary addresses have been acquired.
NOTE
Do not load duplicate telephone numbers into the Directory; telephone numbers should be unique.
4-16 December 1996 3615-A2-GB20-20
Page 61
Operating the DSU
Entering a Telephone Number
For the following example, add a dial string (telephone number) to Backup Directory 1. The number to be entered is 555-1234.
To add or change a telephone number:
. Procedure
Select
1.
2.
3.
4.
5.
Local.
Press the
key to display Confg
branch). Select
Confg.
Select
Dir if entering a telephone number into the
Backup Directory. Press the
entering the local DSU’
telephone number is enter a number into Dir
Select
key to display then select
s telephone number
ed similarly to entering
.
Chang (F1) to add or change a telephone
number. The
Enter Dir
screen appears.
(Configuration
Phone if
. This
For numeric screens, the following applies: — Press the F1 key () to increment the digit. — Press the F2 key () to decrement the digit.
Press the
or
keys to move the blinking cursor one position to the left or right.
— Press the F3 key (Undo) to restore the number
as it was first displayed so you can start over
Refer to Table 4-6 to see all available directory and password entry characters.
7. Press the F1 key until the number 5
8.
Press the Repeat the process until all numbers in the
9.
key to move to the next position.
appears.
telephone number have been entered.
1 : 5 5 5 1 2 3 4
Undo
F1
F2
F3
.
Press the F1 key () to increment the Directory entry indicator (the default is 1). For this example, assume that you are entering your first directory entry.
Select
6.
Load (F2).
The Directory entry appears on the first line; the cursor is positioned in the first position of the currently empty Directory.
1 :
Undo
F1
F2
F3
If the number had been entered previously, that number would appear on the first line, following the colon (:).
NOTE
A dial string cannot have any separating characters or spaces (i.e., 555-1234 or 555 1234).
Other valid characters
interspersed as needed :
can be
*,
#, t,
p, w, and comma (,).
10. Press the key to return to the
Enter Dir
screen. Press the F3 key to
11.
Save the entry.
12. Verify that the number was loaded by pressing the key again and selecting
Load (F2).
The telephone number should appear as entered, or you
can repeat the procedure to edit/correct your entry.
4-173615-A2-GB20-20 December 1996
Page 62
COMSPHERE DualFlow Data Service Units
Phone
5.
Select
Load.
The local telephone number (Phone) feature stores the
local DBM’
Refer to T
number characters.
s telephone number if a DBM is installed.
able 4-6 to see all available telephone
Network Address
The network address (Addr) is the network address of
the local DSU. It is The DSU’s network address is a number in the range of 1 to 254 if the DSU has a DBM installed. The DBM automatically acquires an address equal to the DSU’ plus 1.
only available from the Local branch
s
Assigning an Address
The Addr chapters, Chapters 2 and 3, provide guidelines for assigning an address to the DSU based upon its position in the network – control or tributary to assign a network address to a DSU. Refer to the menu in Appendix A, if necessary
essing the Unit
sections of the installation
. Follow the steps below
.
. Procedure
Press the
1. Select
2. Select
3. menu.
(Press the press the function key (F3) directly below the branch name to select it.)
key to return to the top-level menu.
Local. Confg (Configuration branch) from the
key to scroll Confg into view, then
Net Addr
address displayed. (The DSU is shipped with its network address set to
6. Change the DSU’ blinking cursor and incrementing or decrementing the digits (1 through 9).
.
Press the
7. screen when finished entering the DSU’
8.
Select The DSU displays the address assigned along with
a
If an error was made in entering the address:
ess appears, with the current network
254.)
s network address by moving the
Press the 1 position to the right.
Press the 1 position to the left.
Press the by 1 (e.g., 1, 2, 3, ...).
Press the by 1 (e.g., 1, 2, 3, ...).
Save (F2).
Command Complete
key – moves the cursor
key – moves the cursor
F1 () key – increments the digit
F2 () key – decrements the digit
key to return to the
message.
Net Addr
s address.
ess
. Procedure
Press the
1. screen.
Re-select
2.
3.
Select
key to return to the Configure
Addr, and re-edit the address.
Save
again.
Press the
4. then select
4-18 December 1996 3615-A2-GB20-20
key until Addr
Addr.
(Address) appears,
Page 63
Operating the DSU
Control Branch
The Control (Ctrl) branch allows you to enable or
disable the DSU’s transmitter to display or change the status of the general purpose external DTE leads. A DBM can be disabled if it is
addr
essed fr
om the Remote branch.
Transmitter Control
The Transmitter Control (TxCtl
to enable or disable the DSU’ (DDS core).
When the DSU transmitter is disabled, the following is
possible:
When a DSU is disabled, it responds to tests.
Aborting a test clears the test but the unit remains disabled.
A DSU in test clears the test when a disable (or
enable) command is received.
If an enable command is executed to a control from
the NMS or the local DCP are enabled; all tributaries in test are restored to Data mode.
, as well as the DBM’
) selection allows you
s or DBM’
s transmitter
, all disabled tributaries
s, and
LEDs
The LEDs selection is only available from the Local
branch. This selection allows you to monitor the port at any given time. When selected, the port’
s lead activity is reflected in the DCP circuit designation status indicators (TXD, RXD, etc.) on the faceplate of the Model 3616 DSU, or on the DCP of the Model 3615 DSU.
External Leads
The External Leads (ExtL
display the state of
four general-purpose leads on the EIA-232-D/V.24 port interface: Pins 12 and 13 for output (control leads) and Pins 19 and 23 for input (alarm leads).
When the configuration option Ext Leads (External Leads) is set to ExtLd (DBM Port option set), you can change the state of the two output leads from the DCP or NMS. When
CCN by EL
enabled (DBM Port option set), the control DSU reports changes in the four leads to the NMS as part of its health and status poll response.
T
able 4-7 describes the meaning of the state of each
input or output lead.
) selection allows you to
(CCN by External Leads) is
When the local DBM is disabled, the DBM does not
originate or answer any calls until enabled.
Symbol Meaning
Off (below text line)
ON (above text line)
Changing
?
NOTES:
Input leads A and B:
Off (
) when voltage on lead is less than +.8V.
ON (
Output leads are either ON or Off:
When output is set to Off ( When output is set to ON (
) when voltage on lead is more than +2.2V.
Indicates an illegal value
), –12V is applied to lead.
), +12V is applied to lead.
Table 4-7
Lead States
4-193615-A2-GB20-20 December 1996
Page 64
COMSPHERE DualFlow Data Service Units
Displaying External Leads
The Display (Displ
external lead states. When Display is selected, the External Leads status report appears showing the current status of the general-purpose external leads on the EIA-232-D/V.24 interface.
) selection allows you to view the
Changing External Leads
The
Change ( the state of the two output leads (for example, to change a lead to signal a console operator or to reset a remote computer). Leads can be changed from the NMS.
After the leads are set, press the F2 key to save the
leads in the specified state.
Chang
) selection allows you to change
Reporting External Lead Changes to NMS
Changing either the
changes the DSU’
If the DSU is polled by the NMS, the NMS reports a
change configuration notification (CCN) event. The NMS operator can then issue a CCN Display determine what caused the event.
If the event was caused the state of the
, select
leads
the leads.
output leads
s health and status message.
Displ
(F1) to see the current states of
or the
input leads
command to
external
Message Branch
The
Messages ( allows the DBM to receive messages from the NMS. It only appears when there is a message waiting. Both control and tributary DSUs can receive messages.
T
o receive messages:
Msgs) branch of the top-level menu
. Procedure
1.
Press the F3 key (Msgs).
2.
Select
Read (F1).
If the message is
3. the entire message is displayed.
If the message is greater than the key to scroll additional lines of the message onto the screen.
T
o clear (delete) messages:
less than
16 characters in length,
16 characters, press
. Procedure
1.
Press the F3 key (Msgs).
2.
Select
Clear (F2).
The message is deleted, and appears over the F3 key.
Msgs no longer
If a positive (+) voltage is detected in either one of
input leads
the reported.
, an external leads alarm is also
4-20 December 1996 3615-A2-GB20-20
Page 65
Operating the DSU
Front Panel (DCP) Security
NOTE
This page can be removed to prevent unauthorized persons from learning about the security access levels and their selection.
The Model 3615 diagnostic control panel (DCP) and Model 3616 shared diagnostic control panel (SDCP) have two levels of security access, as shown in T
Table 4-8
Security Access Levels
Security
Access Level
Unlock All Lock Local branch only:
Functions Available
S Status branch S Configuration branch:
Display only (no changes) S Control branch: Display External Leads only (no changes)
able 4-8.
If the security has not been set on the DCP before, the
following appears:
FP
A
ccess: ? ? ?
Lock Unlock Save
F1
To
select the security level:
F2
F3
. Procedure
1.
Press the top-level menu.
2.
Press the three seconds. The following menu appears:
3. Select the security level:
Lock – T Unlock – T
key to ensure that you are at the
and
FP
keys simultaneously for
A
ccess: Unlock
Lock Unlock Save
F1
F2
F3
o restrict access
o provide full access
The DualFlow DSUs are shipped from the factory with the security level set to Unlock. When the DCP is locked, only the Local branch appears on the control DSU and no settings can be changed or saved.
Press the appropriate function key (F1 or F2). Select
4.
Save (F3).
4-213615-A2-GB20-20 December 1996
Page 66

Unit Configuration

Overview 5-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the DCP to Set Configuration Options 5-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Editing Configuration Options 5-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Saving Configuration Options 5-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Example Using the DCP 5-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration Option Tables 5-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Understanding the Tables 5-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
Overview
After
the DSU has been installed and any necessary hardware switches or jumpers have been set, the software configuration options must be set. Configuration options are set via the DCP by accessing the Configuration (Confg) branch of the menu (refer to the menu in Appendix A).
There are eight configuration option areas within the
DSU:
The Active area (Activ) contains the DualFlow
DSU configuration options currently being used.
The Remote area (Remt
DualFlow DSU’ to be retrieved so they can be displayed, edited, and/or saved back to the selected DSU or DBM, another DSU or DBM, or the local DSU or DBM. The remote configuration option sets that can be retrieved are Activ
The User 1 area (Usr1
stored configuration options. By having these predetermined option sets stored, they can be loaded rapidly as operating requirements change.
The User 2 area (Usr2
Usr1, providing further flexibility when creating configurations for various applications.
s or DBM’
) allows a selected
s configuration options
, Usr1, Usr2, and Usr3.
) is a customer
) is functionally the same as
-defined set of
The User 3 area (Usr3) is another customer-defined
option set.
NOTE
The next three option sets, SyBC, SyBT read-only storage areas; changes cannot be saved to these option sets.
The factory-loaded configuration for the
Synchronous Backup application for a control DSU is stored in the
The factory-loaded configuration for the
Synchronous Backup application for a tributary DSU is stored in the
The factory-loaded configuration for the Dial
Diagnostic application is stored in the
A DualFlow DSU cannot configure a non-DualFlow DSU remotely.
, and DiDg, are
SyBC area.
SyBT area.
DiDg area.
NOTE
5-13615-A2-GB20-20 December 1996
Page 67
COMSPHERE DualFlow Data Service Units
Selection of Activ
DiDg from the Load from menu brings a complete set of configuration option into the working buffer the Edit/Save submenu appears (shown below).
, Usr1, Usr2, Usr3, SyBC, SyBT
Edit/Save: SAVE DSU DSUpt
F1
F2
F3
, or
. Once loaded,
Using the DCP to Set Configuration Options
Any one of the following 6 configuration option sets can be selected: DSU, DSU Port, DBM, DBM Port, Diagnostic (DBM and General), and Backup. The configuration options can be edited and then saved to the
, Usr1, Usr2, or Usr3 storage areas.
Activ
In addition, an example is included to illustrate DCP operation.
Editing Configuration Options
To edit or change configuration options:
. Procedure
Select
1.
2.
3.
4.
Local, or Remot (Remote) and the remote
s network address.
DSU’ Select
Confg (Configuration branch).
Press the the function key (F1, F2, or F3) directly below Confg.
Select Select
Load from screen.
the
If the unit is a control
the network address of the remote DSU.
key until Confg appears, then press
Opts (Configuration Options). storage area
(Activ, Remt, Usr1, etc.) from
and you select
Remt, enter
5. Select the option set
etc.) to be edited. The first configuration option within that set
appears. Page through each configuration option within the set as follows:
a. Press the F1 key to go to the Next
configuration option. These configuration options scroll or wrap around (e.g. first, then last; or last, then first).
b. To return to the previous configuration option,
press the Prev appears over the F1 key.
Select
c.
As you edit configuration options, be aware of the
following:
first line
The
the option and its current setting. If configuration data has been corrupted, ??? will
appear in place of the current value. If this occurs, reset all configuration options, along with the network address. Check the Backup Directory entries, the poll list, and the DSU’ number
The
second line
available for selection – three at a time, one above each function key.
Press the
selections into view
— Press the function key (F1, F2, or F3) directly
below a value to select it.
Select Select Prev
— —
Press the submenu or screen, and select the next option set to be edited.
Prev
of each configuration option identifies
, as well.
Next to proceed to the next option.
(e.g., DSU, DSUpt, DBM,
key
instead of
by pressing the F1 key
displays all values that are
or key to scroll other
.
to return to a previous option.
key to return to the Edit/Save
selecting Next.
s local telephone
.
5-2 December 1996 3615-A2-GB20-20
Page 68
Unit Configuration
Saving Configuration Options
CAUTION
Be extremely careful when saving configuration options to avoid saving them to the wrong location.
To save edited configuration options:
. Procedure
1. From any configuration option in any option set, press the submenu.
Press the F1 key below
2.
Select
3.
Save to
If Activ
immediately.
If Usr1,
are stored for future use.
key to return to the Edit/Save
SAVE.
area (Activ, Remt, Usr1, etc.) on the
screen.
is selected
Usr2
, your changes take ef
, or
Usr3
is selected
, your changes
fect
. Procedure
Press the DCP keys indicated by the shading.
V.35 DSU 56 C Local Remot
F1
F2
Local Mode: Stat Bckup Test
F1
F2
Local Mode: Bckup Test Confg
F1
F2
F3
F3
F3
If the unit is a control and Remt
is selected
, the complete set of configurations (all option sets available to the unit) are sent to the tributary and saved to its
Activ area.
Remember that you cannot save to the factory­loaded configuration areas.
Example Using the DCP
In this example, load the configuration options stored
in the DiDg
area. Change option set) from FrcOn to DTE. Then, save the changes to the Usr1 area and return to the top-level menu.
RTS Cntrl (in the DSU Port
Configure: Opts PollL Dir
F1
F2
F3
Load from: Activ Remt Usr1
F1
F2
F3
5-33615-A2-GB20-20 December 1996
Page 69
COMSPHERE DualFlow Data Service Units
Load from: DiDg Activ Remot
F1
F2
F3
Edit/Save: SAVE DSU DSUpt
F3
.35
DT
F1
E P
ort
F2
: V
Next V.35 Prev
F3
RT
F1
S C
ntrl: FrcOn
F2
Next FrcOn DTE
Edit/Save: SAVE DSU DSUpt
F1
F2
F3
Save to: Activ Remot Usr1
F1
F2
F3
Save to: Usr1 Please wait . . .
F1
F2
F3
Save to: Usr1 Command Complete
F3
RT
F1
S C
ntrl: DTE
F2
Next FrcOn DTE
F1
F2
F3
F1
F2
F3
V.35 DSU 56 C Local Remot
F1
F2
F3
5-4 December 1996 3615-A2-GB20-20
Page 70
Unit Configuration
Configuration
This
section contains a table for each can be found under the Configuration (Confg) branch, in the order in which it appears in the menu.
This chapter includes the following option set tables:
DSU Configuration Options (Table 5-1)
DSU Port Configuration Options (Table 5-2)
DBM Configuration Options (Table 5-3)
DBM Port Configuration Options (Table 5-4)
Diagnostic (DBM) Configuration Options
(Table 5-5)
Diagnostic (General) Configuration Options
(Table 5-6)
Backup Configuration Options (Table 5-7)
Option T
option set
ables
that
Understanding the Tables
Refer to the appropriate tables when configuring the DSU. Each configuration option is segmented into three sections: explanation of the option, then the values that can be selected or set.
displayed. As you refer to these tables, be aware of the following:
the option as it appears on the DCP
Each table shows each configuration option as it is
first line
The
it appears on the DCP the default setting (the value set at the factory).
second line
The
can be viewed on the DCP by scrolling to the left or right using the
The first selection is always you to go to the next configuration option in the set.
The last selection is always to go back to the previous configuration option.
Possible selections wrap around so you can immediately press the key to display saving key presses.
shows each
shows all selectable values, which
configuration option
, followed by a colon (:), then
or
key
.
Next
Prev
, an
, which allows
, which allows you
Prev,
as
An explanation of the configuration option and its selectable values follow
The full or unabbreviated name of the configuration
option, followed by a brief explanation of its purpose or function.
The selectable values for the configuration option,
which are listed with guidelines for when each should be selected.
, which includes:
5-53615-A2-GB20-20 December 1996
Page 71
COMSPHERE DualFlow Data Service Units
Table 5-1
DSU Configuration Options
Rate(Kbps): Next 64CC 64L
DSU Rate
and tributary DSUs must be set to the same value.
64CC 64 kbps Clear Channel (on a 72 kbps circuit) with 3600 Series DSUs at both ends of the circuit. 64L 64 kbps LADS operation.
TxClkSource: DDS Next Int RXC Ext DDS Prev
Transmit Clock Source
Int Internal clock source. Timing is taken from the DSU. RXC Receive clock source. The DSU generates its transmit timing from the receive data signal. This choice is
Ext External clock source. The DSU is timed by the external Transmit T DDS DDS Network. This source is used when the DSU is connected to a DDS network and the network
19.2 PowrLvl: +6 Next +
19.2 kbps Power Level
only appears when +6 For DDS network service. 0
–10 For LADS operation.
56
56 38.4 19.2 9.6 4.8 2.4 Prev
. Data rate (in kbps) on the digital circuit. Must be set to match the speed of the DDS circuit. Both the control
. Specifies the transmit timing source for the DSU.
provided for LADS configurations. It differs from the DDS selection during tests.
iming lead.
provides the timing.
6 0 –10 Prev
. Selects the appropriate power level, in dBm, for operation at 19.2 kbps. This configuration option
Rate(Kbps)
For alternate DDS service.
is set to 19.2.
64KScramblng: Off Next On Off Prev
64 kbps Scrambling
suppresses the possible simulation of network control codes by application data. This configuration option must be the same at both the local and remote DSUs. This configuration option only appears when
On Enables data scrambling. Off Disables data scrambling.
64KLatchLpbk: On Next On Off Prev
64 kbps Latching Loopback
Channel operation. This configuration option only appears when Rate(Kbps) is set to 64CC.
On DSU responds to the network latching loopback command. ON is required for compliance with AT&T
Off DSU ignores the network latching loopback command. V.54 Lpbk: Disab
Next Enab Disab Prev
V.54 Loopback
configurations.
Enab This configuration option should be enabled if the remote DTE generates V.54 loopback sequences or if
Disab This configuration option should not be enabled if the remote DTE does not support V.54 loopback
. Controls the data scrambler used with 64 kbps Clear Channel operation. Data scrambling
Rate(Kbps)
. Controls the DSU’s response to the network latching loopback sequence on 64 kbps Clear
Technical Reference 62310 – 1987.
. Enables CCITT V.54 Loopback operation. This configuration option is supported for point-to-point
the DualFlow DSU is communicating with a non-AT&T DSU that supports V.54 signaling.
sequences or other DSUs do not support V
.54 signaling.
is set to 64CC.
5-6 December 1996 3615-A2-GB20-20
Page 72
Unit Configuration
Table 5-2
(1 of 3)
DSU Port Configuration Options
DTE Port: V.35 Next V.35 Prev
DTE Port
V.35 For all available rates at distances up to 1000 feet.
RTS Cntrl: FrcOn Next FrcOn DTE Prev
Request-to-Send Control
set to FrcOn, the DSU internally forces the RTS lead ON; if set to DTE, the DSU sends control mode idle (CMI) whenever RTS is Off, and data mode idle (DMI) when RTS is ON.
For point-to-point configurations with nondisruptive diagnostics, or rate adaption, this configuration option is forced ON internally.
FrcOn The DSU keeps the internal RTS ON continuously, regardless of whether RTS at the DTE interface is ON
DTE The DSU responds to RTS from the DTE. CTS Cntrl: Std
Next Std =RTS Delay FrcOn Prev
Clear-to-Send Control
Std CTS is normally controlled by the DTE’s RTS lead; however, the CTS lead can be affected by the
=RTS RTS Control must be forced on (RTS Cntrl is set to FrcOn). In point-to-point configurations where RTS
Delay CTS does not go Off in response to a network alarm condition or CMI. CTS goes Off only after a
FrcOn Keeps CTS on as long as the DSU has power.
. Forces user data over the V.35 interface.
. This configuration option determines how the DSU will function with respect to the RTS lead. If
or Off.
. Controls the behavior of the CTS lead.
response to abnormal conditions, such as no signal or test mode, as determined by configuration options RTS Cntrl, and Circ Assur.
Cntrl is forced ON, CTS Cntrl can also be forced ON if the DTE interfaces require no delay between RTS Cntrl and CTS Cntrl (0 ms), but does not require an RTS-to-CTS transition.
successful backup connection is established.
AntiStream:Disab Next Chang Prev
Antistreaming
constantly turned ON) by clamping the RTS lead of the tributary DSU. If the tributary DTE turns ON RTS longer than the time specified for the Antistreaming configuration option, the tributary
DSU turns on its alarm indicator and clamps RTS to Off. Although the tributary DTE is not allowed to send, the DSU can still respond to commands and is capable of being tested or disabled.
Upon detecting that RTS is no longer turned ON, the DSU turns Off its alarm and resets the streaming timer, and allows the DTE to send data once again.
This configuration option only has an effect at a DSU configured with RTS Control set to DTE. It is disabled when RTS Control is set to FrcOn.
Chang Set timer to Disab, or to any value from 1 to 100 second(s) in increments of 1. When Disab is selected,
. Antistreaming provides circuit protection against a streaming DTE (a defective DTE that has its RTS lead
streaming terminal detection is not provided.
5-73615-A2-GB20-20 December 1996
Page 73
COMSPHERE DualFlow Data Service Units
Table 5-2
(2 of 3)
DSU Port Configuration Options
LSD Lead: Std Next Std Delay FrcOn Prev
Line Signal Detect Lead
Std LSD lead goes Off in response to a control mode idle (CMI) signal from the DDS network or DDS failure. Delay LSD does not go Off in response to a network alarm condition or CMI. LSD goes Off only after a
FrcOn Keeps LSD on as long as the DSU has power. DSR FrcOn: Enab
Next Enab Disab Prev
successful backup connection is established.
Data Set Ready Forced On
Enab DSR remains ON as long as the device is working, regardless of tests and network alarms. Disab DSR functions as an active lead reflecting various test and alarm conditions and other options.
SystemStat: Enab Next Enab Disab Prev
System Status
from the network.
Enab Network alarm turns Off DSR. Disab Network alarm does not affect DSR.
. Controls the behavior of the DSR lead in response to a No Signal, Out-of-Service, or Out-of-Frame alarm
. Controls behavior of the Line Signal Detect lead.
. Provides the ability to override any other options controlling the Data Set Ready lead.
DSR on Tst: Enab Next Enab Disab Prev
Data Set Ready On in Test
Enab DSR is ON continuously during testing, allowing a DTE that relies on DSR being ON to send test
Disab DSR is Off during testing. Circ Assur:Disab
Next Enab Disab Prev
Circuit Assurance
RTS and RTS Cntrl is set to FrcOn, this configuration option is ignored. A DDS Facility Alarm condition turns Off the CTS lead, regardless of the Circuit Assurance setting.
Enab The DSU will turn Off the CTS lead if the DSU receives control mode idle (CMI) from the network. Disab The DSU is not affected by the receipt of CMI.
RespondRDL:Disab Next Enab Disab Prev
messages to the DSU.
. Controls behavior of the CTS lead in response to a data signal from the network. If CTS Cntrl is set to
Respond to Remote Digital Loopback
Enab Performs a Digital Loopback. Disab Ignores the Loopback command.
. Controls the behavior of the DSR lead during testing.
. Determines whether the DSU responds to a V.54 Remote Loopback request.
5-8 December 1996 3615-A2-GB20-20
Page 74
Unit Configuration
Table 5-2
(3 of 3)
DSU Port Configuration Options
LL by DTE: Disab Next Enab Disab Prev
Local Loopback by DTE
DSU is the active device. Whenever this lead is ON, the Local Loopback overrides any other diagnostic tests run by the network.
Enab The DTE forces the DSU into Local Loopback when the signal on Pin L is turned ON. Local Loopback
ends when the signal is dropped.
Disab The DTE will not initiate Local Loopback in response to the signal on Pin L. Bilat Lpbk:Disab
Next Enab Disab Prev
Bilateral Loopback
Enab When enabled, DTE Loopback occurs whenever a Digital Loopback occurs. Disab Disables Bilateral Loopback.
DTR Alarm: Disab Next Enab Disab Prev
Data Terminal Ready Alarm
30 seconds. The DCP displays
Enab If DTR lead turns Off for 30 seconds, the DSU generates an alarm. Disab Regardless how long the DTR lead is Off, no alarm is generated.
. Controls using Pin L of the V.35 interface by the DTE to initiate a Local Loopback when the
. If this configuration option is enabled, a DTE Loopback occurs when a Digital Loopback occurs.
. Causes the DSU to generate an alarm if DTR over the V.35 port is Off for more than
DTR Alarm
and reports the alarm to the NMS.
Table 5-3
(1 of 4)
DBM Configuration Options
Rate(Kbps): Next 14.4 12.0 9.6 4.8 2.4 Prev
DBM Rate
14.4 V.32bis modulation. This rate is not displayed for a 12.0 kbps DBM.
12.0 —V
9.6 —V
4.8 —V
2.4 —V
PrtSp(Kbps): 9.6 for V.32 DBM, 56 for Switched 56 DBM Next 56 48 38.4 32 28.8 19.2 18.8 18.0 16.8 14.4 12.0 9.6 9.2
8.4 7.2 4.8 4.4 4.0 2.4 2.0 1.2 Disab Prev
Port Speed
only be displayed when a Switched 56 DBM is installed; 14.4 kbps will not be displayed for a 12.0 kbps DBM.
56 to Selects the port speed. When a V.32 DBM is installed and the DiDg configuration is loaded the
1.2 default is 9.6 kbps. When a Switched 56 DBM with SyBC or SyBT configuration, the default is 56 kbps. Disab Sets the port speed to 0.
9.6
. Initial data rate (in kbps) for dial backup calls.
.32bis modulation. .32bis modulation. .32bis modulation. .22bis modulation.
. If this value is set to less than the DBM rate, the DBM performs rate adaption. Rates above 14.4 kbps will
Only appears for a V.32 DBM.
5-93615-A2-GB20-20 December 1996
Page 75
COMSPHERE DualFlow Data Service Units
Table 5-3
(2 of 4)
DBM Configuration Options
TxClkSource: Int for a control DBM, RXC for a tributary DBM Next Int RXC Ext Prev
Transmit Clock Source
Int Internal clock source. The local DBM provides the timing. This source is used primarily in point-to-point
RXC Receive clock source. This source is used primarily in multipoint tributary applications. Ext External clock source. This source is used primarily in applications where the connected DTE must
CarrLossDisc: Yes Next Yes No Prev
applications.
provide the timing, such as when a 3616 V.32 DBM with its DBM Yes and where timing is received from the digital bridge.
Carrier Loss Disconnect
signal becomes unacceptable.
Yes Call is terminated upon loss of carrier. No For factory testing only. Never set Carrier Loss Disconnect to No. Doing so will cause an off-hook line
Auto Retrain:Yes Next Yes No Prev
condition, resulting in excessive telephone charges.
Automatic Retrain
unacceptable.
Yes Retraining is initiated automatically. No Retraining is not initiated automatically; however, the DBM will respond to a retrain request from a remote
Only appears for a V.32 DBM.
modem.
. Source of timing for the DBM.
. Controls whether the V.32 DBM terminates a call when the receive signal carrier is lost or the
. Controls the automatic start of a retrain sequence by the DBM when received signal quality becomes
Only appears for a V.32 DBM.
Primary Core
configuration option set to
Single Rate: No Next Yes No Prev
Single Rate
must be set to Yes if rate adaption or non-disruptive diagnostics are enabled. If Rate(Kbps) is set to 2.4, the DBM can only talk to a 2.4 kbps modem, regardless of the Single Rate setting. (Will only
train at 2.4 kbps.)
Yes The DBM operates only at the rate for which it is configured. No The DBM will adjust its rate downward to correct a mismatch.
AutoAnswer: Enab Next Enab Disab Prev
Automatic Answer
Enab DBM answers incoming calls. Disab DBM does not answer incoming calls.
.
Determines whether the DBM will adjust its rate to resolve a rate mismatch with a remote DBM. Single Rate
Only appears for a V.32 DBM.
. Controls whether the DBM answers incoming calls.
5-10 December 1996 3615-A2-GB20-20
Page 76
Unit Configuration
Table 5-3
(3 of 4)
DBM Configuration Options
Call Setup:None Next None Pswrd Cllbk Alarm Prev
Dial Backup Call Setup
selections use a proprietary password exchange to ensure that the DBM does not route line data to the DBM’s DTE interface. If security fails, the call is disconnected. These password exchanges only work between 3600 Series DBMs.
None No security. Outgoing calls have no security. For incoming calls, if the calling device is not a 3600 Series
DBM, an answering DBM with Call Setup set to None will automatically switch from Standby to Dial Backup mode after the time-out period has expired.
Pswrd Intermediate security level. The originating and answering DBMs must exchange valid passwords to
establish a call.
Cllbk Highest security level. The originating and answering DBMs exchange passwords and disconnect; the
answering DBM calls the originator back with a second exchange of passwords.
Alarm Causes a DBM to answer incoming calls only when the DSU reports a Facility Alarm. No security
checking is performed. This feature is for customers that provide data services to other customers that may not have non-3600 Series DBMs.
RxPwd: Next Chang Prev
Receive Password
remote DBM’s TxPwd). The maximum password length is 10 characters. The default, *, is a wildcard meaning “any character string.”
Chang Enter up to 10 characters for the receive password. An underscore ( _ ) to the immediate right of the last
password character is required for passwords of fewer than 10 characters in length. To make the password invisible to the DCP, enter a comma ( ,) as the first character.
. Establishes the security level on call setup attempts. The Password and Callback security
.
The password that the DBM expects to receive from a remote DBM (must be the same as the
When Call Setup is set to None or Alarm, this configuration option will not appear
.
TxPwd: Next Chang Prev
Transmit Password
RxPwd). The maximum password length is 10 characters. The default is a null password.
None or Alarm, this configuration option will not appear
Chang Enter up to 10 characters for the receive password. An underscore (_ ) to the immediate right of the last
Dial Test:Disab Next Enab Disab Prev
Dial Test
Test Failure alarm in its health and status. A Dial Test occurs once every 60 minutes until a failure occurs. Then, the test repeats every minute until the network recovers.
If enabled, the V for receipt of a data mode idle (DMI) signal burst (referred to as goes off-hook and checks for receipt of a proceed-to-select message from the switch.
Enab Enables the Dial Test. Disab Disables the Dial Test.
. When enabled, the DBM periodically checks for a signal or dial tone. If the test fails, the DSU reports a Dial
. The password that the DBM sends to a remote DBM (must be the same as the remote DBM’s
When Call Setup is set to
.
password character is required for passwords of fewer than 10 characters in length. To make the password invisible to the DCP, enter a comma ( ,) as the first character.
.32 DBM periodically tests receipt of dial tone, the 4-wire Switched 56 DBM goes off-hook and checks
winkback detection
), and the 2-wire Switched 56 DBM
5-113615-A2-GB20-20 December 1996
Page 77
COMSPHERE DualFlow Data Service Units
Table 5-3
(4 of 4)
DBM Configuration Options
Primary Core:No Next Yes No Prev
DBM Primary Core
Switched 56 DBM.
Yes Enables the Primary Core so the unit operates like a 3600 Series DBM-V, DBM-S, or DBM-D. No Disables the Primary Core so that the DSU function is active.
DTRCallCon:Orig for SyBC, Ansr for DiDg and SyBT configurations Next Orig Ansr Disab Prev
Data Terminal Ready Call Control
DBM originates a backup. When set to Ansr, the DBM only answers a backup call when DTR is active. The DTR lead is ignored when DTRCallCon is disabled.
. When enabled, the DSU is disabled and the DBM is enabled so that it functions as a V.32 DBM or
No is the factory-set (default) setting for a
DualFlow DSU.
. DTRCallCon uses the state of the DTR lead to control backup. When set to Orig, the
Orig DTR lead is used for
when DTR is raised based upon the number stored in the Backup Directory specified by the Backup Dir configuration option, and drops the call when DTR goes low. The DBM will try to call the number ten times, or until (
A phone number must have been entered into the Backup Directory. If a call cannot be completed, check
outgoing
TriesTimeOut
Expanded Health and Status messages
Ansr DTR lead is used for
Disab Disables DTR Call Control; the state of the DTR lead is ignored. EchoCancel:Disab
Next Enab Disab Prev
Echo Cancel
network is US SPRINTr or when the network has echo cancellers. Disable this configuration option if the DBM is interfaced to an AT&T Switched 56 kbps 4-wire service facility.
Enab Enables Echo Cancel. Disab Disables Echo Cancel.
Remot DBM:4-wire Next 2-wire 4-wire Prev
Remote Dial Backup Module
process completion time can be determined. This configuration option only appears for a 2-wire Switched 56 DBM with
EchoCancel
2-wire Originating remote DBM is a 2-wire Switched 56 DBM, so the process completes in 460 milliseconds. 4-wire Originating remote DBM is a 4-wire Switched 56 DBM, so the process completes in 3.85 seconds.
Msg Clamp: Enab Next Enab Disab Prev
Message Clamping
from the remote DBM.
Enab Received Data (RXD) is held to MARK and LSD is turned Off during diagnostic exchanges. This prevents
Disab DSU passes diagnostic messages to the DTE interface. Use the Disable setting if the remote DSU is
goes low or will not answer an incoming call if DTR is low.
. This configuration option is only displayed for a Switched 56 DBM and is required if the Switched 56 kbps
. Specifies the identity of the far-end Switched 56 DBM so the appropriate dial backup
enabled. If unsure of whether the remote DBM is 2-wire or 4-wire, select 4-wire.
. Controls behavior of the data leads when disruptive diagnostic tests and commands are received
diagnostic messages from reaching the DTE interface.
configured for switched RTS (RTS Control is set to DTE).
incoming
calls. When Orig is selected, the DBM originates (dials out) a backup call
expires. If Multicall is also enabled, the DBM uses the multiple calling cycle.
.)
calls. When Ansr is selected, the DBM drops a backup call when DTR
5-12 December 1996 3615-A2-GB20-20
Page 78
Unit Configuration
Table 5-4
(1 of 3)
DBM Port Configuration Options
DTE Port: 232 Next 232 V.35 Prev
DTE Port Primary Core
232 For the EIA-232-D connector, the maximum cable length from the DBM to the router is 34 feet with
V.35 Only appears if Primary Core (DBM option set) is set to Yes. For the V.35 connector, all rates are
RTS Cntrl: FrcOn for DiDg, DTE for other configurations Next FrcOn DTE Prev
Request-to-Send Control
FrcOn The DBM keeps the internal RTS ON continuously, regardless of whether RTS at the DTE interface is ON
DTE The DBM responds to RTS from the router. CTS Cntrl: Std
Next Std =RTS FrcOn Prev
Clear-to-Send Control
Std CTS is normally controlled by the router’s RTS lead; however, the CTS lead can be affected by the
=RTS CTS follows RTS. FrcOn CTS remains ON as long as the DSU has power.
. Selects which DTE port will be used for DBM data. This configuration option is forced to 232 (EIA-232) unless
is set to Yes.
shielded cable and 68 feet with unshielded cable when operating at 56 kbps.
available for distances up to 1000 feet.
. This configuration option determines how the DBM will function with respect to the RTS lead.
or Off. FrcOn should be used when the DBM is connected to the console port of a router since the router does not support RTS signalling.
. Controls the behavior of the CTS lead.
response to abnormal conditions, such as no signal or test mode.
AntiStream:Disab Next Chang Prev
Antistreaming
constantly turned ON) by clamping the RTS lead of the tributary DBM. If the tributary DTE turns ON RTS longer than the time specified for the Antistreaming configuration option, the tributary
DBM turns on its alarm indicator and clamps RTS to Off. Although the tributary DTE is not allowed to send, the DBM can still respond to commands and is capable of being tested or disabled.
Upon detecting that RTS is no longer turned ON, the DBM turns Off its alarm and resets the streaming timer, and allows the DTE to send data once again.
This configuration option only has an effect at a DBM configured with
Chang Set timer to Disab, or to any value from 1 to 100 second(s) in increments of 1. When Disab is selected,
LSD Lead: Std Next Std FrcOn Prev
Line Signal Detect Lead
Std LSD lead goes Off in response to a loss of carrier or a switched network failure. FrcOn Keeps LSD on as long as the DBM has power.
. Antistreaming provides circuit protection against a streaming DTE (a defective DTE that has its RTS lead
RTS Cntrl
streaming terminal detection is not provided.
. Controls behavior of the Line Signal Detect lead.
set to DTE.
5-133615-A2-GB20-20 December 1996
Page 79
COMSPHERE DualFlow Data Service Units
Table 5-4
(2 of 3)
DBM Port Configuration Options
DSR FrcOn: Enab Next Enab Disab Prev
Data Set Ready Forced On
Enab DSR remains ON as long as the device is working regardless of tests and network alarms. Disab DSR functions as an active lead reflecting various test and alarm conditions and other options.
DSR on Tst: Enab Next Enab Disab Prev
Data Set Ready On in Test
Enab DSR is ON continuously during testing, allowing a DTE that relies on DSR being ON to send test
messages to the DBM.
Disab DSR is Off during testing. RespondRDL: Disab
Next Enab Disab Prev
Respond to Remote Digital Loopback
Enab Performs a Digital Loopback. Disab Ignores the Loopback command.
RL by DTE: Disab Next Enab Disab Prev
Remote Digital Loopback by DTE
DTE or router to initiate a Remote Digital Loopback.
NOTE: Use of Pin 18 or Pin L is determined by the DBM’s Enab The DTE or router forces the DBM to request a Remote Digital Loopback when the signal on Pin 21 or
Pin N is turned ON. Remote Digital Loopback ends when the signal is dropped.
Disab The DTE or router cannot initiate Remote Digital Loopback.
. Provides the ability to override any other options controlling the Data Set Ready lead.
. Controls the behavior of the DSR lead during testing.
. Determines whether the DBM responds to a V.54 Remote Loopback request.
. Allows Pin 21 of the EIA-232-D/V.24 interface or Pin N of the V.35 interface by the
DTE Port
configuration option.
Bilat Lpbk: Disab Next Enab Disab Prev
Bilateral Loopback
Enab When enabled, DTE Loopback occurs whenever a Digital Loopback occurs. Disab Disables Bilateral Loopback.
Ext Leads: Rate Next ExtLd Rate RPowr Prev
External Leads
These leads can be controlled and monitored from the DCP or a 6700 or 6800 Series NMS.
ExtLd Enables Pins 12 and 13 as output (control) and Pins 19 and 23 as input (alarm) leads. When enabled,
Rate Pin 12 on the port is turned Off to indicate that the DBM is in fallback mode. If the port does not fall back
RPowr Functions similarly to ExtLd, but the inputs report power failure or fan alarms when a redundant power
5-14 December 1996 3615-A2-GB20-20
. If this configuration option is enabled, a DTE Loopback occurs when a Digital Loopback occurs.
. Controls the general-purpose leads on the EIA-232-D/V.24 interface except when Rate is selected.
Pins 12 and 13 output +12V when ON and –12V when Off. Pins 19 and 23 recognize voltages from +2.2V to +12V as ON (reported as an External alarm) and –12V to +.8V as Off.
and remain at the same speed, then the fallback feature in the DCE or router connected to that port
should not be enabled.
supply is installed in the COMSPHEREr 3000 Series Carrier.
Page 80
Unit Configuration
Table 5-4
(3 of 3)
DBM Port Configuration Options
CCN by EL: Disab Next Enab Disab Prev
Configuration Change Notification by External Leads
event. This configuration option only has an effect if
Enab Change in state of a general-purpose lead signals CCN to the NMS. Disab General-purpose lead changes do not set a CCN event.
DTR Alarm: Disab Next Enab Disab Prev
Data Terminal Ready Alarm
displays
Enab If DTR lead turns Off for 30 seconds, the DSU generates an alarm. Disab Regardless how long the DTR lead is Off, no alarm is generated.
AsyncSync: Enab for DiDg, Disab for SyBC and SyBT configurations Next Enab Disab Prev
DTR Alarm
and reports the alarm to the NMS.
Asynchronous-to-Synchronous Conversion
Enab Configures the DBM as asynchronous (asynchronous-to-synchronous conversion takes place). Disab Configures the DBM as synchronous.
AsyncBit/Char: 8 for DiDg configuration Next 6 7 8 9 10 Prev
Asynchronous Bits per Character
stop bits. This configuration option only applies to the Dial Diagnostic (DiDg) configuration. 6 to 10 Selects the asynchronous bits per character. When Stop Bits is set to 2, 10 will not be displayed.
. Causes the DSU to generate an alarm if DTR is Off for more than 30 seconds. The DCP
. Sets the DBM port for asynchronous or synchronous operation.
. Specifies the length of a character, including the parity bit but excluding the start and
. Controls using the general-purpose output leads to set a CCN
Ext Leads
is set to ExtLd.
Stop Bits: 1 for DiDg configuration Next 1 2 Prev
Stop Bits
Dial Diagnostic (DiDg) configuration.
1 to 2 Selects the number of stop bits to be used. When the AsyncBit/Char configuration option is set to 10, 2
Overspeed: 2.3 for DiDg, not applicable for other configurations Next 1.0 2.3 Prev
Overspeed
only displayed when the AsyncSync configuration option is enabled.
1.0 Selects the basic overspeed range. Basic range provides 1.0% overspeed in the DTE or router
2.3 Selects the overspeed percentage for extended range. Extended range provides 2.3% overspeed in the
. Specifies the number of stop bits in an asynchronous character. This configuration option only applies to the
will not be displayed.
. Selects the overspeed range of the asynchronous-to-synchronous converter. This configuration option is
asynchronous data rate.
DTE or router asynchronous data rate.
5-153615-A2-GB20-20 December 1996
Page 81
COMSPHERE DualFlow Data Service Units
Table 5-5
Diagnostic DBM Configuration Options
Diag Type: Disr Next NonD Disr None Prev
Diagnostic Type
set consistently for all Dualflow DBMs on the same circuit.
NonD Nondisruptive Diagnostics. An in-band secondary channel transport is derived to carry diagnostics data
Disr Disruptive Diagnostics. The same (primary) channel that carries user-transmitted data between the
None No diagnostic communications with remote devices; only local diagnostics are allowed. 2nd Ch(bps): 400
Next 100 400 800 1200 1600 Prev
In-band Secondary Channel Diagnostic Transport Speed (in bps)
(nondisruptive diagnostics) is selected and there is no excess bandwidth available for in-band secondary channel transport operation. (This configuration option only appears when DiagType = NonD.)
The selection entered here allocates DBM port bandwidth to the in-band secondary channel transport. For example, both the DBM port speed and the backup line speed are 9.6 kbps, and the Diagnostic Type entered is NonD and the In-band Secondary Channel Diagnostic Transport Speed entered is 400. The resulting DBM port speed is 9.2 kbps. (Refer to the following list for valid diagnostic speeds.)
If the DBM Rate(Kbps) is equal to Port Speed: Valid diagnostic speeds are:
1.2
2.0
2.4
4.0
4.8
7.2
8.4
9.6
12.0
14.4
16.8
18.0
19.2
28.8 32
38.4 48 56
. Defines the diagnostic interaction between the control and tributary DBMs in Backup mode. It must be
between the control and the tributary DBMs.
control and the tributary DBMs also carries diagnostic data. This mode should be selected for compatibility with earlier releases that use session-disruptive diagnostics.
. Determines the DBM’s port speed when NonD
100, 400 100, 400 100, 400, 800 100, 400, 800 100, 400, 800, 1200, 1600 100, 400, 800, 1200 100, 400, 1600 100, 400, 800, 1200, 1600 100, 400, 800, 1200 100, 400, 800, 1200, 1600 100, 400, 800, 1200 100, 400, 1200 100, 400, 800, 1200, 1600 100, 400, 800 100, 400, 800, 1200 100, 400, 800, 1200, 1600 100, 400, 800, 1200, 1600 100, 400, 800, 1200
5-16 December 1996 3615-A2-GB20-20
Page 82
Unit Configuration
Table 5-6
Diagnostic General Configuration Options
Position: Cntrl for SyBC, Trib for DiDg and SyBT configurations Next Cntrl Trib Prev
Network Position
Cntrl Control Trib Tributary
RemoteDiag:Enhan Next V.54 Enhan Prev
Remote Diagnostics
V.54 The V.32 DBM generates a CCITT V.54 loopback sequence. This selection does not appear for a
Enhan The V.32 DBM uses enhanced 3600e protocol and the Switched 56 DBM uses Br56. Both the control and
Link Delay: 0s Next 0s 1s 2s 5s 10s 20s 50s Prev
Link Delay
downstream. This configuration option does not appear when Diag Type (Diagnostic DBM option set) is set to Disr and Position is set to Trib (DiDg and SyBT configurations);
control.
. Determines the DSU’s position in the network, and defines its test and diagnostic capabilities.
. Determines the type of loopback message generated by a DBM.
Switched 56 DBM.
tributary must be set for Enhan.
. Controls the additional time (in seconds) that a control DBM will wait for a response from a device one level
this configuration option only appears for a DBM configured as a
NOTE: If diagnostic time-outs are occurring during polling, increase the link delay to the next higher value. 0s to 50s Sets the time the DBM will wait for a downstream device response. Packet Delay: 0s
Next 0s 1s 2s 5s Prev
Packet Delay configuration option only appears for a DBM configured as a control
NOTE: Must be used when the DualFlow DSU’s diagnostic channel operates over packet switch, satellite
0s to 5s Sets the time the DBM will wait for the NMS.
. Controls the time (in seconds) that a control DBM will wait for a packet to complete from an NMS.
.
communications, or other facilities that provide extended throughput delays.
This
5-173615-A2-GB20-20 December 1996
Page 83
COMSPHERE DualFlow Data Service Units
Table 5-7
(1 of 2)
Backup Configuration Options
Auto Bckup:Disab Next Enab Disab Prev
Automatic Backup
detection of No Signal or Out-of-Service codes, or excessive bipolar violations. (Automatic dial attempts begin after the Network Time-out expires.)
NOTE: The backup connection is made through the EIA-232 port. Enab Upon detecting a failure of the DDS network, the DSU waits for a period equal to DDS T
Disab No automatic attempt is made to establish a dial backup connection. Backup Dir: 1
Next Chang Prev
Backup Directory
display shows the identifier of the current default dial string to be used to set up a dial backup call for automatic backup as described in the Auto Bckup configuration option, or when the backup command is received from the DCP or the NMS.
Chang Produces a data entry display for changing the directory entry identifier. BckupOnCMI:Disab
Next Enab Disab Prev
Backup on Control Mode Idle
condition as a facility alarm to trigger automatic dial backup. Configuration option
Enab Upon detecting CMI for 250 to 500 milliseconds from the network, the DSU attempts to establish a dial
Disab No attempt is made to establish a dial backup connection if CMI is detected.
. Controls automatic initiation of a call setup attempt upon failure of the DDS network, defined as
DDS network is still down, it attempts to establish a dial backup connection to the number specified by the Backup Directory pointer after the Network Time-out expires.
. The DBM can store 10 dial strings or telephone numbers, identified by the numbers 1 through 10. This
. This configuration option determines whether the DSU treats a control mode idle (CMI)
Auto Bckup
backup connection to the router after the DDS Time-out expires. When enabled, CMI will also generate a Facility Alarm (FA). Do not use this configuration option if the DSU is configured to generate CMI.
must be enabled.
imeout, and if the
AutoRestor:Disab Next Enab Disab Prev
Automatic Restoration
determines that the DDS circuit has been returned to service.
DTRCallCon
When
Enab Restoral of the DDS circuit triggers automatic restoration (after the Restoration Time-out expires). Disab Restoral of the DDS circuit does not trigger automatic restoration. Disable when
NtwkTimOut: 0:20 for a control DSU, 01:00 for a tributary DSU Next Chang Prev
Network Time-out
sequence is made. This configuration option only has an effect if
. Controls whether the DSU automatically terminates the dial backup call when the DSU
is enabled (set to Orig or Ansr), disable
. Length of time the DDS network must remain out of service before the dial backup call attempt
AutoRestor
Auto Bckup
.
is set to Enab.
DTRCallCon
is enabled.
When configured for
nondisruptive diagnostics or rate adaption, this configuration option must be set to greater than or equal to 20 seconds.
Chang Calls up a data entry display for changing the current value which can range from 1 second to
30 minutes. The cursor has two positions: a minutes field with a range of 0 to 29, and a seconds field with a range of 00 to 59.
5-18 December 1996 3615-A2-GB20-20
Page 84
Unit Configuration
Table 5-7
(2 of 2)
Backup Configuration Options
RestorTimOut: 5m Next Chang Prev
Restoration Time-out
attempted. This configuration option only has an effect at a DSU configured with Automatic Restoration enabled.
Chang Calls up a data entry display for changing the current value, with a range of 1 to 60 minutes. TriesTimeOut:15m
Next Chang Prev
Call Attempts Time-out
configuration option only has an effect if whether MultiCall is enabled (multiple calling cycle) or disabled (normal calling cycle).
Only 10 call attempts are made for the normal calling cycle. If a call attempt is in progress and the timer expires, the call attempt will not be aborted.
Chang Calls up a data entry display for changing the current value, with a range of 1 to 60 minutes. MultiCall:Disab
Next Enab Disab Prev
Multiple Calls
each valid dial string in the directory, or selects the normal calling cycle. This configuration option only has an effect if
Auto Bckup
Enab The DBM makes one attempt to call the dial string in the directory pointed to in the Backup Directory
Disab The normal calling cycle is used: three call attempts, a 5-minute wait, three more call attempts, another
NOTE: Multicall must not be enabled unless successive telephone numbers in the Backup Directory are dif
. Selects the multiple calling cycle in which the DBM steps through the Backup Directory
is set to Enab or if
addition, duplicate telephone numbers should be avoided. These precautions prevent the DBM from making excessive call attempts to the same telephone number.
. Length of time the DDS network must be back in service before automatic restoration is
. Sets an overall time limit for dial backup call attempts upon failure of the DDS network. This
Auto Bckup
DTRCallCon
configuration option (default is the first dial string in the directory). If the attempt fails, the DBM makes an attempt to call the next dial string in the directory, and so on until either a call is completed or the DBM cycles through all the dialed strings in the Backup Directory, ignoring blank entries. The DBM then waits five minutes and begins the calling cycle again until the TriesTimeOut period expires.
5-minute wait, etc., until the TriesTimeOut period expires.
is set to Orig.
is set to Enab, or if
DTRCallCon
is set to Orig, regardless of
, attempting to call
ferent. In
5-193615-A2-GB20-20 December 1996
Page 85

DSU Menu

Overview A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Menu Structure A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Top-Level Menu A-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Local/Remote Menu Subbranches A-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A
Overview
This menu is your map through the DSU’ functions and pathways. Compare it against the menus that appear as you move through procedures. You will learn to quickly access where you want to go on the menu when operating the DSU.
the handy Refer which can be r
ence Car
emoved and placed with your DSU
(This menu is also included on
d that comes with this guide,
s various
.)
Menu Structure
The DSU’ that branch downward from its starting point, the top-level menu, like the roots of a tree. The menu is sometimes referred to as a
Top-Level Menu
The top-level menu is the starting point for all DSU operations. Y anywhere in the menu by pressing the
this key immediately terminates any operation or work in progress.
s operation is represented as menu selections
menu tr
ou can always return to this point from
ee.
key
. Pressing
The following shows an example of the top-level menu for a standalone Model 3615 DSU that is configured as a control operating at 9.6 kbps, with an NMS message waiting.
232 DBM 9.6 C Local Remot Msg
F1
The following information is displayed:
Line 1 – Source of the information being displayed
–DSU’s current function or mode (In this
example, the unit is operating as a DBM,
not as a DSU.) –DSU’ –DSU’s network designation (Here the
DSU is a control.)
If this display was for a Model 3616 (a
carrier-mounted DSU), the carrier (nest or
rack) and slot numbers would appear
instead of port interface (e.g., Carrier 2
and Slot 16 would appear as 2:16).
F2
s data rate
F3
Line 2 –
Continued on Page A-4.
Menu selections, one appearing directly
over each function key (F1 and F2).
A-13615-A2-GB20-20 December 1996
Page 86
COMSPHERE DualFlow Data Service Units
A-2 December 1996 3615-A2-GB20-20
Page 87
DSU
Menu
A-33615-A2-GB20-20 December 1996
Page 88
COMSPHERE DualFlow Data Service Units
Continued
fr
om Page A-1.
If both DDS and dial connections have been made, then every 10 seconds the top-level menu screen alternates status information between the DDS and dial ports (V.35 for the DDS line and active DBM port for the dial line).
V.35 DSU 56 C Local Remot Msg
F1
F2
F3
In the example above, the top-level menu is displaying the status of the DDS port interface.
Press a function key to select one of the following branches:
Local branch
Remote (Remot) branch – Only available to a DSU
configured as a control or a point-to-point tributary with a dial connection.
Messages
(Msgs) branch – Only appears when a message from the NMS is waiting. Once the message is cleared, this branch no longer appears.
Local/Remote Menu Subbranches
The Local
Remote
The Status (Stat) branch provides reports on the
The Backup (Bckup) branch controls operation of
branch menu has
branch menu has
four:
five
subbranches; the
health and status of the DSU and DBM, the DTE interface, the identity of the DSU and DBM, the status of the connected DTE’s EIA-232 and V.35 interfaces, and if there is a dialed connection, the quality of the dial network circuit.
the dial backup feature. This branch is only available from the Local branch.
The Test
branch provides extensive testing capabilities for the DSU; the DDS circuit; the DBM; and the backup circuit, if there is a backup call established.
NOTE
If the Test branch does not appear, the DSU is in Display mode (values can be read, but not changed).
Only authorized persons can change configuration option values for the DSU. Contact your
System Administrator
for further
information.
The Configuration (Confg) branch allows you to
customize DSU software configuration options, to enter and change telephone numbers, and to change the DSU network address.
The Control (Ctrl) branch allows you to display
and change external leads, and enable or disable the DSU or DBM.
Each selection leads to a functional subbranch of the
menu.
Only three menu selections appear at a time, one over
each function (F1, F2, F3) key
. Press the
and keys to scroll backward or forward through menu selections.
Press the
screen/menu display Press the
key to go to the previous
.
key to return to the starting point –
the top-level menu.
Refer to Chapters 4 and 5 for additional DCP operation
information.
A-4 December 1996 3615-A2-GB20-20
Page 89

Configuration Worksheets

Overview B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Instructions B-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B
Overview
The Configuration W software configuration options and the selections that can be set for each. The Configuration Option T Chapter 5 provide further explanation of each configuration option should you need to change settings, as well as an example showing how to change or edit these options.
Refer to the Configuration Option Tables Chapter 5, when configuring the unit, or when more detailed configuration information is needed.
orksheet summarizes the DSU’
ables in
section,
s
Instructions
Configuration Worksheets can be used for reference, or they can be used to record changes made to the DSU’ configuration options or to record the configurations saved to the Usr1, Usr2, or Usr3 storage areas.
1. Complete the information at the top of each worksheet first.
If you have a Model 3615 (standalone) DSU, enter your site in the location field.
If you have a Model 3616 (carrier-mounted) DSU, enter the DSU’s carrier and slot location. Also, make a copy for each DSU.
2. Circle the appropriate setting(s) – either all of the configuration option changes, or only those changed from their factory-loaded (default) settings.
Store the worksheets so they will be available
3. when needed.
s
B-13615-A2-GB20-20 December 1996
Page 90
DualFlow DSU Configuration Worksheet (1 of 2)
Date:_____________________________________________ Location:____________________________________________
Device:___________________________________________
Serial No:_________________________________________
DSU Value
Rate(Kbps) 64CC,
TxClkSource
19.2 PowrLvl
64KScramblng
64KLatchLpbk
V
.54 Lpbk
Hardware Straps
DDD Interface
Frame Ground/ Signal Ground
T
est Mode Indication Enabled, Disabled
*
64L, 56, 38.4, 19.2, 9.6, 4.8, 2.4
Int, RXC, Ext, DDS
+6, 0,
–10
On, Of
f
On, Of
f
Enab, Disab
Value
Permissive, Programmable
Connected, Disconnected
Local
Addr:__________________________________________
Tributary Network Addr:________________________________
DSU Port (V
DTE Port
R
TS Cntrl
CTS Cntrl Std, =R
AntiStream
LSD Lead
DSR FrcOn
SystemStat
DSR on T
Circ Assur
RespondRDL
LL by DTE
Bilat Lpbk
DTR Alarm
.35) Value
V.35
FrcOn, DTE
TS, Delay
(Chang)
st
Disab (1–100 sec)
Std, Delay
Enab, Disab
Enab, Disab
Enab, Disab
Enab, Disab
Enab, Disab
Enab, Disab
Enab, Disab
Enab, Disab
, FrcOn
, FrcOn
Local
Phone No: (
DBM Value
Rate(Kbps){
PrtSp(Kbps)
TxClkSource{
CarrLossDisc{
Auto Retrain
Single Rate
AutoAnswer
Call Setup
RxPwd{{
TxPwd{{
Dial T
Primary Core
DTRCallCon
{
est
{
j )_____________________________
14.4,
12.0,
(Chang) (Chang)
9.6, 4.8,
56, 48, 38.4, 32, 28.8, 19.2, 18.8,
16.8, 14.4, 12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.4,
2.4,
2.0,
4.0,
Int, RXC, Ext
Y
es, No
Y
es, No
Y
es, No
Enab, Disab
None, Pswrd, Cllbk, Alarm
Enab, Disab
Y
es, No
Orig, Ansr
, Disab
1.2,
2.4
Disab
18.0,
(up to 10 digits)
(up to 10 digits)
{ V
.32 DBM only
{{Only if Call Setup set to Pswrd
*
Switched 56 DBM only
**
2-wire Switched 56 DBM only
EchoCancel *
Remot DBM
Msg Clamp
Enab, Disab
**
2-wire, 4-wire
Enab, Disab
Page 91
DBM
Port (232)
Value
DualFlow DSU Configuration Worksheet (2 of 2)
Diagnostic DBM
Value
Backup Value
DTE Port
R
TS Cntrl
CTS Cntrl Std, =R
AntiStream
LSD Lead
DSR FrcOn
DSR on T
RespondRDL
RL by DTE
Bilat Lpbk
Ext Leads
CCN by EL
DTR Alarm
AsyncSync
AsyncBit/Char
Stop Bits
Overspeed
(Chang)
st
232, V.35}
FrcOn, DTE
Disab (1 to 100 sec)
Std, FrcOn
Enab, Disab
Enab, Disab
Enab, Disab
Enab, Disab
Enab, Disab
ExtLd, Rate, RPowr
Enab, Disab
Enab, Disab
Enab, Disab
6, 7, 8, 9,
1,
2
1.0,
2.3
TS, FrcOn
10
Diag T
ype
2nd Ch(bps)
Diagnostic General
Position
RemoteDiag
Link Delay
Packet Delay
{{{
}}
}}
NonD, Disr
100, 400,
Cntrl, T
V.54{, Enhan
0s, 1s, 2s, 5s,
0s,
rib
1s, 2s,
, None
800,
5s
1200, 1600
Value
10s, 20s,
50s
Auto Bckup
Backup Dir
BckupOnCMI
AutoRestor
NtwkTimOut
RestorTimOut
TriesTimeOut
MultiCall
Backup Directory
1
2
3
4
5
6
7
(Chang)
(Chang)
(Chang)
(Chang)
Enab, Disab
(1–10)
Enab, Disab
Enab, Disab
min and
min and sec (1 to 60 min)
min and sec (1 to 60 min)
Enab, Disab
sec (1 to 30 min)
Dial String
{ V
.32 DBM only
{{{
Only if Diag T
}Only if Primary Core set to Y
}}Only at the Control
ype set to NonD
8
9
es
10
Page 92
Status Indicators and
Control Panel Messages
Overview C-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Status Indicators C-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control Panel Messages C-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Format C-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Health and Status Messages C-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Progress Messages C-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Error Messages C-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
This
appendix describes the status indicators on the DSU’s control panel, the diagnostic control panel (DCP) for a Model 3615 and the shared diagnostic control panel (SDCP) for the Model 3616.
Informational messages that may appear on the control panel while a command is executing, or when a command is prevented from executing, are also described.
C
Status Indicators
Status indicators provide information on the current operating condition of the DSU. The status indicators of the Model 3615 DSU appear on the DCP’s faceplate. The status indicators for the carrier-mounted Model 3616 DSU are spread across the the faceplate of the DSU, the SDCP and the faceplate of the shared diagnostic unit (SDU), if installed. Refer to the Installation Manual for SDU status indicator information. The DSU DCP and SDCP status indicators are described in T
ables C-1 and C-2.
COMSPHERE 3000 Series Carrier
,
C-13615-A2-GB20-20 December 1996
Page 93
COMSPHERE DualFlow Data Service Units
Table C-1
DSU Status Indicators
Label Color Description
OK Green Health and status indicator: DSU operation is normal. (The DSU has not
detected any of the faults listed under Alrm, below.)
This indicator flashes two times per second if a message from the NMS is present.
Alrm Red Health and status indicator:
There is a fault in the local or remote DSU, DBM, or DDS facility, or there is a corrupted configuration.
The following alarms at the local or remote DSU cause the Alrm status indicator on the affected DSU to light:
Configuration Corrupt Device Fault Dial Tone Test Failure DTR Alarm Facility Alarm MUX Failure No Response Redundant Power Alarm Streaming Terminal Subnetwork Alarm Out-of-Frame Threshold Out-of-Service
Test Yellow Active device (DSU or DBM) is either performing a test or other DSUs or DBMs
are in Test mode.
1
Dial Yellow DBM is active
Rapid flashing: Call setup in progress Slow flashing: Call established but in Standby mode Steady ON: Backup call established and active
TXD, RXD, RTS, CTS, DSR, DTR, LSD
Front Panel
(Model 3616 only)
1
The DSU or DBM is automatically put into Test mode when a remote DSU or DBM is performing a disruptive test (e.g., a
Green Internal lead states at the DSU/DTE interface
Control circuit active or Data circuit SPACE(ing).
Yellow DSU is currently selected at the SDCP.
.
)
time
(The SDCP addresses one DSU at a
(circuit designations)
:
Local Loopback (LL) at the control DSU. A DSU or DBM in Test mode has its DTE interface turned Off).
C-2 December 1996 3615-A2-GB20-20
Page 94
Status Indicators and Control Panel Messages
Table C-2
SDCP Status Indicators
Label Color Description
OK Green Health and status indicator for the selected DSU; mirrors the OK indicator on
the DSU faceplate.
Alrm Red Health and status indicator for the selected DSU; mirrors the Alrm indicator on
the DSU faceplate.
BckUp Yellow Mirrors the BckUp LED on the selected DSU. Test Yellow Mirrors the Test indicator on the selected DSU. EC Green Error Correction indicator is for future use by dial network modems.
Control Panel Messages
This
section shows the screen format of messages appearing on the control panel and describes the various messages.
Three types of messages are included:
status, progress, and error messages.
health and
Format
The format of the control panel messages is shown
below.
Command Name Message
F1
F2
F3
Health and Status Messages
There
are three types of health and status messages. Device Health and Status messages are described in T
able C-3, Expanded Health and Status messages are described in Table C-4, and Subnetwork Health and Status messages are described in T
able C-5.
C-33615-A2-GB20-20 December 1996
Page 95
COMSPHERE DualFlow Data Service Units
Table C-3
(1 of 3)
Device Health and Status Messages
Message Condition
CMI Fac Alarm Facility Alarm on CMI (FacAlOnCMI) configuration option is enabled and control mode
idle (CMI) is being received.
Config Corrupt Configuration is corrupt. Reset all configuration options from one of the default
(factory-loaded) option sets stored in the DiDg, SyBC, or SyBT area. DBM:Device Fail Internal failure is detected in the DBM. DBM:Disable DBM transmitter is disabled. DBM is in Idle mode, but no calls can be initiated or
answered. DBM F:
nn.n
DBM:
nn.n
ExternBU
DBMTst:
alarm
mode nn.n
test,init
A DBM facility alarm;
BiplrVio l — Excessive Bipolar Violations FDHP Lost — High-level communication over the signaling channel switch
OutofServc — Out-of-Service condition (4-Wire Switched 56 DBM only) No Signal — No signal has been received (Switched 56 DBM only)
indicates the DBM speed;
Standby — A dialed connection is made, but the data is still routed over the DDS Active — A dialed connection is made, and data has been routed over that line.
nn.n
indicates the external DBU’s speed:
External — Backup is in progress on an Bkup disabled.)
The DBM is running a test, initiated from
test
is one of the following tests:
BERT — Bit Error Rate Test BiL — Bilateral Loopback Dev — Device Test DL — Digital Loopback DT — Digital Test DTE — DTE Loopback E-E — End-to-End Test Lamp — Lamp Test NetL — Network Loopback (Switched 56 DBM only) RL — Remote Digital Loopback TM — Test Mode
init
is one of the following initiators:
DCP — Diagnostic Control Panel DTE — Data T NMS — Network Management System Remt — Remote DSU
alarm
is one of the following network alarms:
has been lost (2-Wire Switched 56 DBM only)
mode
is one of the following:
circuit. The first line shows the dial backup connection time.
erminal Equipment
init
external
.
DBU. (DDS line is
C-4 December 1996 3615-A2-GB20-20
Page 96
Table C-3
(2 of 3)
Device Health and Status Messages
ConditionMessage
Dial Tone:Fail Dial tone test was enabled and test failed.
Status Indicators and Control Panel Messages
DDS F:
DSU:Device Fail Internal failure in the DSU is detected. (Go to the Test branch for Device Test.) DSU:Disable DSU transmitter is disabled. (Go to the Control branch to enable the DSU.) DSUTst:
alarm
test,init
Digital facility alarm;
BiplrViol — Excessive Bipolar Violations Fac Alarm — Facility Alarm OutofServc — Out-of-Service condition No Signal — No signal has been received
The DSU is running a test, initiated from
test
is one of the following tests:
BERT — Bit Error Rate Test BiL — Bilateral Loopback Dev — Device Test DL — Digital Loopback DT — Digital Test DTE — DTE Loopback Lamp — Lamp Test NetL — Network Loopback TM — Test Mode
init
is one of the following initiators:
DCP — Diagnostic Control Panel DTE — Data T NMS — Network Management System Ntwk — Network Remt — Remote DSU
alarm
is one of the following network alarms:
init
erminal Equipment
.
External Alarm A The DSU detects a positive voltage on Pin 23. This alarm condition is defined by the
Ext Leads configuration option. External Alarm B The DSU detects a positive voltage on Pin 19. This alarm condition is defined by the
Ext Leads configuration option. Invalid Address A DSU was powered up with an invalid address. Invalid addresses are:
0 192 191
255
— This is reserved for the SDU — This is reserved for the broadcast address — Invalid for a DSU with a DBM because of the reserved 192
broadcast address
— Invalid for a DSU with a DBM
C-53615-A2-GB20-20 December 1996
Page 97
COMSPHERE DualFlow Data Service Units
Table C-3
(3 of 3)
Device Health and Status Messages
ConditionMessage
Redun Fan Alarm Indicates a problem with the fan on the –48 Vdc Central Office Power Unit. Redun Pwr Alarm Indicates a problem with the power on the –48 Vdc Central Office Power Unit. Subnetwrk Alarm A major alarm was set Off by one of the devices in your subnetwork. Check the
Subnetwork Health and Status report. Subtree Truncat Downstream health and status information has been truncated because it overflowed
system limits. OutofFrameThresh For DBMs operating on a single port (rate adaption or nondisruptive), the local DBM
has detected a continuous Out-of-Frame condition. The alarm clears when a local DBM
synchronizes with a remote DBM.
On a point-to-point circuit, if the alarm continues and the local DSU is configured for
automatic backup, the local DSU disruptively tests the DDS circuit. If the test fails, the
local DSU initiates a DDS Facility Alarm and initiates dial backup.
nn.n
DDS Indicates the speed (
nn.n
) of the DSU core when there are no alarms.
nnn
Disable Transmitter at
DSU or DBM.)
nnn
DTR Alarm The DTR lead at
nnn
StreamTerm Streaming terminal. DTE at
the predefined time.
nnn
(DSU or DBM) is disabled. (Go to the Control branch to enable the
nnn
(DSU or DBM) has been Off for more than 30 seconds.
nnn
(DSU or DBM) has its RTS lead turned ON longer than
C-6 December 1996 3615-A2-GB20-20
Page 98
Table C-4
Expanded Health and Status Messages
Message Condition
Status Indicators and Control Panel Messages
Dial Attempt:
Drop:DTR Disc An established dialed connection fails because the DTR lead was turned Off. Failn:
reason
No Expanded H/S There are no Expanded Health and Status messages.
nn
The number (nn) of failures of dialing attempts since failure of private-line service. This
message is cleared when the automatic backup process succeeds or the backup
process is reset due to configuration option changes. When the maximum number of
retries has been reached, Max appears.
Because of failure in the DDS private line, the DSU automatically originated several
unsuccessful dialing attempts. The last three dial attempts are reported as Fail1
(oldest), Fail2, and Fail3 (most recent).
The
reason
for failed dial attempts include:
Abort Call — User aborted call. BadPermiss — A dial attempt was made, but a backup connection already
Bad Phone# — Unassigned number or illegal characters. Busy — Line or network busy. DBM Disab — DBM disabled; no call can be initiated or answered. DTR Discon — DTR disconnected. NetwkAbort — The network has disconnected the call. Netwk Busy — The network cannot put the call through. NetwkUnavl — The Switched 56 kbps network is incapable of passing data. No Answer — There is no answer at the remote DBM or modem. No Dial Tone — No dial tone received from the network. No Ringing — DBM is not getting ringback from the other end. Security — Originating and answering DBMs have incompatible
Training — V
exists.
security levels or unmatched passwords.
.32 modem training failure.
Tries Timer:
nn
The number of minutes left in Tries Time-out Timer (1– 60) which is initially set to the
time limit for dial backup call attempts. If the timer has expired, Exp appears.
C-73615-A2-GB20-20 December 1996
Page 99
COMSPHERE DualFlow Data Service Units
Table C-5
Subnetwork Health and Status Messages
Message Condition
Devic TDM/Flex only: Device Failure. One of the following major alarms is in effect:
Configuration Corrupt
Device Test Failure DialBU Dial mode. Indicates that the DBM is active. DialCN Dial Connect. Indicates that the DBM is in Standby mode. DialTn Dial Tone Test failure. Disab Indicates that the DSU or DBM is disabled. DTR DTE alarm. Data Terminal Ready lead is Off. ExtLd External lead alarm A or B. Facil DDS facility alarm. Indicates a network facility alarm. NoResp The active poll list member did not respond. Probable cause: a facility problem, a
remote DSU problem, or an incorrect poll list. Normal Active poll list member does not report an alarm or its status. RPower Redundant power supply alarm. Stndby DBM is in Dial Standby. Stream Streaming terminal. SubSpd Subnormal operating speed. Test Test mode. It could be a DSU or DBM test. Thresh Threshold is exceeded. TribTm Tributary time-out. Tributary is not answering polls. Trunc Subtree truncation. More information is being received than can be returned in the poll.
You must access each tributary for its messages.
C-8 December 1996 3615-A2-GB20-20
Page 100
Progress Messages
T
able C-6
T
able C-7 describes the dial backup progress messages.
Please wait . . . Command is taking more than 2 seconds to complete. Command Complete Command has been completed. Command Failed Command was unable to be executed.
describes the command progress messages;
Table C-6
Command Progress Messages
Message Condition
Table C-7
Dial Backup Progress Messages
Status Indicators and Control Panel Messages
Message Condition
DBM:Answering DBM is answering an incoming call. DBM:Callback Callback sequence has initiated. DBM:Connected DBM is connected. DBM:Disabled No calls can be initiated or answered. DBM:FoundAnswTon A 4-wire Switched 56 DBM is answering an incoming call. DBM:Ringing Ringing at remote DBM or DBM:Standby A connection is made but the digital circuit is still the active link. DBM:Starting Up The DBM is training for synchronization. DBM:WaitForAnswr A call has been placed and the DBM is waiting for connection. DBM:Wait Callbck The DBM is expecting a call back from remote DBM or DBM:WaitForSync Call placed and waiting for connection (2-wire Switched 56 DBM only). DBM:xxxxxxxxxxx The last 1
1 digits for the telephone number that has been dialed.
external
DBU (dial backup unit).
external
DBU.
C-93615-A2-GB20-20 December 1996
Loading...