ACCULINK 3161 DSU/CSU
QUICK REFERENCE
Document No. 3161-A2-GL11-40
Copyright 1998 Paradyne Corporation.
All rights reserved.
Printed in U.S.A.
Notice
This publication is protected by federal copyright law. No part of this publication may be
copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated
into any human or computer language in any form or by any means, electronic,
mechanical, magnetic, manual or otherwise, or disclosed to third parties without the
express written permission of Paradyne Corporation, 8545 126th Avenue North, P.O.
Box 2826, Largo, Florida 33779-2826.
Paradyne Corporation makes no representation or warranties with respect to the
contents hereof and specifically disclaims any implied warranties of merchantability or
fitness for a particular purpose. Further, Paradyne Corporation reserves the right to
revise this publication and to make changes from time to time in the contents hereof
without obligation of Paradyne Corporation to notify any person of such revision or
changes.
Changes and enhancements to the product and to the information herein will be
documented and issued as a new release to this manual.
Warranty, Sales, and Service Information
Contact your sales or service representative directly for any help needed. For additional
information concerning warranty, sales, service, repair, installation, documentation, or
training, use one of the following methods:
Via the Internet: Visit the Paradyne World Wide W eb site at
http://www.paradyne.com
Via Telephone: Call our automated call system to receive current information via
fax or to speak with a company representative.
— Within the U.S.A., call 1-800-870-2221
— International, call 727-530-2340
T rademarks
All products and services mentioned herein are the trademarks, service marks,
registered trademarks or registered service marks of their respective owners.
TM
ACCULINK 3161 DSU/CSU
Quick Reference
Document Number 3161-A2-GL11-40
February 1998
Quick Start Procedure
The following procedure is for experienced DSU/CSU users who are familiar with the
3161 DSU/CSU installation process and have no special requirements for their
application. See the
Operator’s Guide
Auxiliary Backplane.
1. Install the Auxiliary Backplane onto the 3000 Series Carrier. See the
3151 CSU and 3161 DSU/CSU General Information Guide
installation procedures.
ACCULINK 316x Data Service Unit/Channel Service Unit
(3160-A2-GB21) for more information. A copy is included with the
ACCULINK
(3100-A2-GK40) for
2. Attach the DTE cable (DB15) and/or port cables (DB25) to the appropriate
connectors on the Auxiliary Backplane. See the
Installation Manual
Connect the other end of the DTE cable to the customer premises equipment.
(3000-A2-GA31) for detailed cable and connector information.
1
COMSPHERE 3000 Series Carrier
3. Attach the network cable to the Auxiliary Backplane using either a 50-pin cable or
the T1 Network Interface Adapter. Connect the other end of the network cable to
the connection provided by the telephone company .
COMSPHERE
3000 Series
Carrier (Rear)
Auxiliary
Backplane
over Slots 9–16
Cable
Retainer
T1 Network
Cable
496-14386-0
4. Turn on the power to the 3000 Series Carrier.
2
5. Insert the DSU/CSU circuit card into the appropriate slot in the carrier. The
power-up self-test begins.
495-1479
6. If you intend to use front panel emulation, connect the cable from the PC to Port 2
on the Auxiliary Backplane using the COM port adapter and COM-port-to-PC cable.
7. If you do not intend to use the DTE Drop/Insert T1 port, disable it using the
configuration procedures in Chapter 3,
Options
Operator’s Guide
, of the
ACCULINK 316x Data Service Unit/Channel Service Unit
(3160-A2-GB21). (The default setting for this port is Enabled.)
Operation
, and Appendix C,
Configuration
8. The Factory 1 configuration for ESF framing format and B8ZS line coding format is
the default configuration and is appropriate for most networks. If this configuration
does not work for you, try the Factory 2 configuration for D4 framing format and
AMI line coding format. To further customize configuration options, refer to
Changing Configuration Options
Configuration Options
Unit Operator’s Guide
, in the
.
in Chapter 3,
Operation
, and Appendix C,
ACCULINK 316x Data Service Unit/Channel Service
9. During the power-up self-test, the FAIL LED flashes, then all LEDs blink twice.
When the test is complete, verify that the DSU/CSU is functional by observing that
the OK, NETWORK SIG, and DTE SIG LEDs are lit.
10. Configure the ports and channels you intend to use and assign channels to the
network interface.
3
Configuration Options
Configuration options are accessed from the Cnfig branch of the front panel menu.
DSU ESF
Stat
DevHS
STest Perf TSt at LED ID
Cur
Intvl
24Tot
LLBUP
Cur
54UP
LLBDN
Test
T1 PrtnPrtnUserTelco
FarNear
Rlpbk Lpbk Ptrns Lamp
Intvl
8Tot
FT1UP
54DN
PLB DLB RLBLLBAbort DCLB DTLB
FT1DN
Abort Mon
QRSS 1in8 511
Cnfig
ACO
Call
DiscDial ChDir
Send
QRSS 511
Load Edit Area From:
Activ Cu st1 Cu st2 Fact1 Fac t2
Choose Function:
Edit
1 . . 5,A
(Directory)
Save
Cust1Activ Cust2
User AlarmNETDTE Port Chan Gen Mgmt
1 . . 5,A
(Directory)
Rel ClrReg
User Prt1 Prt2
DTE Prt1 Prt2
Ctrl
Reset
CID
FarNear
PasswdLED
Mon
DL
EQPT NET
Copy Prt1 Prt2
Port Select :
All Prt1 Pr t2
ClearDsply
DTE Prt 1
4
Prt2
Gen Trap
97-15577