Paradox Security Systems PARAKEYTX, PARAKEYRX PROGRAMMING GUIDE

Remote Control Options
Keys (on/off)
[1] [2] [3] [4] [5] [6] [7] [8]
Section [17]
Section [18]
Section [19]
Section [20]
Section [21]
Section [22]
Section [23]
Section [24]
OFF Key On
[1] Set arming methods [2
] see table on
[3
] next page Disabled[4] * Button 1 PGM Enabled Disabled[5] * Button 2 PGM Enabled Disabled[6] * Button 3 PGM Enabled Disabled[7] * Button 4 PGM Enabled Disabled[8] * Panic Enabled (simultaneously
press buttons 1 and 2 to activate a panic alarm)
= Button 1 = Button 2
References to button 3 & 4 refer to 4-button remote controls.
318/433MHz V1.10
PROGRAMMING CARD
Press “PROG” button + [ENTER] + [INSTALLER CODE] + [SECTION] +
required data
+ [ENTER]
* = DEFAULT SETTING
Section Data Description
[00] __/__/__/__/__/__ Installer Code* (757575) [01] __/__/__/__/__/__ User Access Code 1 [02] __/__/__/__/__/__ User Access Code 2 [03] __/__/__/__/__/__ User Access Code 3 [04] __/__/__/__/__/__ User Access Code 4 [05] __/__/__/__/__/__ User Access Code 5 [06] __/__/__/__/__/__ User Access Code 6 [07] __/__/__/__/__/__ User Access Code 7 [08] __/__/__/__/__/__ User Access Code 8
[09]
Press [ENTER] & button 1 twice to assign RC to User 1 l
[10]
Press [ENTER] & button 1 twice to assign RC to User 2 l
[11]
Press [ENTER] & button 1 twice to assign RC to User 3 l
[12]
Press [ENTER] & button 1 twice to assign RC to User 4 l
[13]
Press [ENTER] & button 1 twice to assign RC to User 5 l
[14]
Press [ENTER] & button 1 twice to assign RC to User 6 l
[15]
Press [ENTER] & button 1 twice to assign RC to User 7 l
[16]
Press [ENTER] & button 1 twice to assign RC to User 8 l
PARKEP-02
}
Panic Output Programming
Section [25]: __
(select one digit only)
ÔÔ
[0] = Disabled [1] = Activate output 1 on panic alarm [2] = Activate output 2 on panic alarm
* [3] = Activate output 3 on panic alarm
[4] = Activate output 4 on panic alarm
Panic Lockout Timer
Section [26]: __
(select one digit only)
ÔÔ
* [0] = Disabled
[1] = 30 second signal lockout on panic alarm [2] = 60 second signal lockout on panic alarm [3] = 90 second signal lockout on panic alarm [4] = 120 second signal lockout on panic alarm
Key Key Key Description
[1]
[2
]
[3
]
____________________________________________ Off Off Off No Arming & Disarming On Off Off * Button 1 = Regular Arming Off On Off Button 2 = Regular Arming On On Off Button 1 = Regular Arming
Button 2 = Regular Arming Off Off On Button 1 = Away Arming On Off On Button 1 = Away Arming
Button 2 = Stay Arming Off On On Button 1 = Regular Arming
Button 2 = Stay Arming On On On Button 1 = Stay Arming
Section [35]: General Options
OFF Key ON
4-Digit __ [1] __ * 6-Digit Access Codes
PGM only __ [2] __ *
Panic activates enabled PGM & sends panic command to control panel
PGM Options Keys (on/off)
[1] [2] [3] [4]
PGM1 PGM2 PGM3 PGM4
Section [31]: Button 1 (default: [1] on) ___ ___ ___ ___ Section [32]: Button 2 (default: [2] on) ___ ___ ___ ___ Section [33]: Button 3 (default: [3] on) ___ ___ ___ ___ Section [34]: Button 4 (default: [4] on) ___ ___ ___ ___
Key ON activates corresponding PGM Key OFF disables corresponding PGM
PGM Options Timing
Section [27]: __ PGM 1
(select one digit only)
Section [28]: __ PGM 2
(select one digit only)
Section [29]: __ PGM 3
(select one digit only)
Section [30]: __ PGM 4
(select one digit only)
ÔÔ
[0] = Latched [3] = 10 seconds [6] = 60 seconds [1] = 1 second [4] = 20 seconds [7] = 2 minutes
*
[2] = 5 seconds [5] = 40 seconds [8] = 4 minutes
Loading...