Paradox Security Systems PARAKEYRX, PARAKEYTX User Manual

Remote Arming Module V1.10
318MHz/433MHz
With
KEELOQ
high-security code encryption
Installer’s Guide
PARKEI-02
TABLE OF CONTENTS
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 Technical Specifications. . . . . . . . . . . . . . . . . . . . 3
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 Location & Mounting . . . . . . . . . . . . . . . . . . . . . . 4
2.2 Power & Communication . . . . . . . . . . . . . . . . . . . 4
2.2.1 With Esprit Control Panel
. . . . . . . . . . . . . 4
2.2.2 Stand Alone
. . . . . . . . . . . . . . . . . . . . . . . 5
2.3 Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.4 Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.5 Programmable Outputs (PGMs) . . . . . . . . . . . . . . 6
2.6 Hand-Held Remote Control . . . . . . . . . . . . . . . . . 7
2.7 System Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
HOW TO PROGRAM . . . . . . . . . . . . . . . . . . . . . . 11
PROGRAMMING THE SYSTEM . . . . . . . . . . . . 13
4.1 Access Code Length . . . . . . . . . . . . . . . . . . . . . 13
4.2 Installer Code . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.3 User Parameters . . . . . . . . . . . . . . . . . . . . . . . . 13
4.3.1 User Access Codes
. . . . . . . . . . . . . . . . 14
4.3.2 Remote Control Assignment
. . . . . . . . . . 15
4.3.3 Remote Control Options
. . . . . . . . . . . . . 16
4.4 Panic Output Programming . . . . . . . . . . . . . . . . 17
4.5 Panic Lockout Timer . . . . . . . . . . . . . . . . . . . . . 18
4.6 PGM Output Timing . . . . . . . . . . . . . . . . . . . . . . 18
4.7 Button PGM Options . . . . . . . . . . . . . . . . . . . . . 19
4.8 Panic Option . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
1 1
INTRODUCTION
The PARAKEY is a wireless remote control system that consists of a receiving module and up to eight 2 or 4-button remote controls (transmitters). When used in conjunction with any
Paradox Esprit Series Control Panel
, remote controls can perform actions such as remote arming and disarming, communicating panic alarms and/or activating programmable outputs (PGMs). Each remote control is assigned to a specific user and therefore, identifies the user to the control panel when used. If desired, it can be used as a stand-alone system where the remote controls will only activate the on-board PGM outputs. When a button on the remote control is pressed, it will transmit an RF signal. When the PARAKEY receives this signal, it then processes the request and performs the programmed action(s).
• Simple, user-friendly programming.
• Supports 8 User Codes, each linked to a unique RF
Code (2 or 4-button remote control).
• Encrypted RF codes for additional security. Does not
use DIP switch programming.
• 4 programmable outputs (PGMs).
• Stand-alone operation (trigger PGMs only) or in
conjunction with a
Paradox Esprit Series Control Panel
(arm/disarm, panic & PGM activation).
• Programming keypad connects directly to the Parakey
Receiving Module.
• Programmable Installer Code.
• Software reset.
1.2.1 Receiver:
Compatible Programming Keypads: (616 V4.2A & up)
(626 V4.1A & up) DC input: 12VDC PGM outputs: 4 PGM Output 1-3 Current Rating: 30mA max. PGM Output 4 Current Rating: 5A relay Max Transmission Range: 53.34m (175 ft.) Operating Conditions: 0°C to 50°C Operating Humidity: 85% Operating Frequency: 318 or 433.92MHz Sensitivity: -110dbm
1.2.2 Remote Control:
Water Resistant Battery:
Lithium 3V (CR2032) Battery Life: Apprx. 2 years Power Transmission: 7mW Current Consumption:
6mA (transmission)
1.2 Technical Specifications
1.1 Features
2 3
INSTALLATION
We recommend installing the receiver in a centralized location on the main floor. Avoid installing the receiver in the basement. Although, if desired, it can be installed in proximity of the control panel. When selecting an installation site please take into consideration that the maximum reception distance of the receiver is approximately 54 meters (175 feet) line of sight. The circuit is static sensitive, thus take great care during handling.
Avoid installing the receiving module near or in the path of strong RF fields, such as neon lights or computers. Also avoid installing the receiver on or near metal objects, circuit breaker boxes, air conditioners and heater ducts. These devices may cause interference, reducing the receiver's sensitivity.
If installing the Parakey away from the control panel, mount the Parakey Receiver Module on a wall, leaving at least 2" around the panel box to permit adequate ventilation/heat dissipation. Selecting a site that is not susceptible to drastic changes in temperature and humidity.
2.2.1 With Esprit Control Panel
When used in conjunction with any
Paradox Esprit Series
Control Panel
, the auxiliary terminals (12VDC) of the
control panel may power the Parakey Receiving Module as shown in figure 3. If using an external power source please ensure that the "
GND" of the receiver and the
power source are connected to the "AUX-" terminal of the control panel.
The "GRN" and "YEL" terminals of the control panel must be connected to the "GRN" and "YEL" terminals of the Parakey Receiving Module in order to provide communication between the modules. Alternatively, you can use a 4-pin serial connector between the control panel's "SERVICE KEYPAD" connector and the Parakey Module's "PANEL" connector.
2.2.2 Stand Alone
When used as a stand-alone system, you will need a
Paradox 12VDC 801 Power Supply
and a 12VDC backup battery. Connect the power supply and the backup battery as shown in figure 4.
The Parakey Receiving Module is programmed using a 616 or 626 Esprit LED Keypad. Connect the keypad as shown in figure 3 or 4. Alternatively, you can connect the keypad to the Parakey Module's "
PROGRAM" connector
using a 4-pin serial connector.
The Parakey can only be programmed using:
616 keypad version 4.2A and up or 626 keypad version 4.1A and up.