Paradox Security Systems NVR35M Users manual

Front cover
Captive screw
Mounting screw 1
Mounting Tam pe r screw 2
Tam pe r knockout hole
Knockout holes
123
DIP switches
Sensitivity trimmer
Default PIR Sensitivity level: 2
Note: After selecting the required
level, the LED flashes the number of times equal to the level selected. EXAMPLE: If level 2 is selected, the LED flashes twice.
NVR35M
Installation Manual V1.0
Wireless Outdoor/Indoor
Window and Sliding Door
Dual Detector with
Anti-Masking and
Pet Immunity
4. Attach the Main Unit to the back cover - ensure the locks snap closed..
NVR35M-EI01
General Description
Installing the NVR35M
1. Remove the front cover - open the Captive screw.
Figure 1 – Removin g the Front Cover Figure 2 – Main Unit
2. Remove the Main Unit: open the two snap-lock mechanisms on each side of the back cover attaching the Main Unit to the back cover as displayed below. Then remove the Main Unit.
Figure 5 – Attaching the Main Unit
5. Insert two AA butteries.
6. Set DIP switch settings (see Table 1 below) according to requirements.
Figure 6 – Adjusting the settings
Tab le 1 : DI P Switch F unc tio nal ity
Dip Switch
Number
1LED
2
*3 RF
Func tion Mode Description
ON: Default OFF:
PET Immunity/ SHARP Mode
ON: PET Immunity mode OFF: SHARP mode
ON: 433MHz * (default) OFF: 868MHz- applicable for EU
versions only
* For USA and Canada: 433MHz frequency is set by the manufacturer and
cannot be modified.
Figure 3 – Removing the Main Unit
3. Pull the wires from the control panel through the knockout holes and mount the back cover onto the window frame or wall using screws..
Figure 4 – Mounting the Back Cover
7. Set Range/PIR Sensitivity level: Turn the Sensitivity Trimmer (see Figure 6 above) to select the required level as displayed below..
Figure 7 – Sensitivity Trimmer
8. Replace the front cover and close the Captive screw.
Warning: Do not obscure the detector's field of view.
Testing the NV35MX
Perform a Wa lk-Test to test successful installation: Walk slowly across the far end of the detection range. Ensure detection.
Walk test mode lasts 5 minutes after the tamper screw is closed.
PARADOX.COM
Beam Pattern
LED Display
PET Mode
SHARP Mode
Top View
Feature LED Status Indicator
Feature LED Status Indicator
Tamper open
PIR sensitivity level setting
Alarm detection
Booting
Green: ON for 0.3 seconds every 30 seconds
Green: Flashes 1-3 times according to the selected level
Red: ON for 2 seconds
Green/Red alternating flashes for 30 seconds
Technical Specifications
Model Number NVR35M
Infrared sensor type 2 dual elements
Detection range PET ON: up to 7.5m
Sharp ON: up to 10m
Detection range • PET Immunity mode: up to 7.5m 7.5 x
2m (25 x 7 ft)
• Sharp mode: 10 x 2m (33 x 7 ft)
Anti- mask Active IR detection for blocking 30cm and
sprayed liquid
Input voltage 3VDC=2x1.5VDC AA Alkaline batteries
Current consumption 40μA in Standby
30mA in Alarm/RF Transmitting
Battery life 3 years of typical use
Low battery voltage Signal
Compatibility RTX3 and Magellan systems
Outdoor protection IP54
Operation temperature -35°c / +50°c
Relative humidity 95% non-condensing
RF Frequency 433.92 MHZ/868MHz
Dimensions 12.3 x 6.1 x 4.3 cm (4.8 x 2.4 x
Certifications EN50131-2-2 Grade 2, Class IV
Weight 100g / 0.2 lb
2.5V
IMPORTANT: For US and Canada, only 433.92 MHz is used
1.7 in.)
Certification Body: Applica Test & Certification
Notification
Changes or modifications to this equipment not expressly approved by the party responsible for compliance (Paradox Security Systems Ltd.) could void the user’s authority to operate the equipment.
Warranty
The Limited Warranty Statement found on the website www.paradox.com/ terms.
Your use of the Paradox product signifies your acceptance of these terms and conditions.
The following US patents may apply 5,886,632 and 6,215,399, Other Canadian and international patents may apply.