Paradox Security Systems DGPR910 User Manual

4-Wire Indoor/Outdoor Proximity Reader
Fi
DGP-R910 V1.0
780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADA
Tel.: (450) 491-7444 Fax: (450) 491-2313
PRINTED IN CANADA - 04/2006 DGPR910-TI00
paradox.com
gure 1: 4-wire Connection / Conexión de 4 Cables /
Raccordement à 4 fils
DGP-ACM1 1
1. Red / Rojo / Rouge
2. Black / Negro / Noir
3. Green / Verde / Vert
4. White / Blanco / Blanc
English
Technical Specifications
Power Input: 11Vdc to 14.5Vdc Current Consumption 100mA, With Card 115 mA Frequency: Exciter field 125 KHz Pulse Modulated Operating Temperature: -35°C (-31°F) to +65°C (149°F) Output Formats: RS-485 Cable Distance: 300m (1000 ft.) Cables: 4-wire Cables (Twisted Pair recommended)
All specifications are subject to change without notice.
Features
Tricolour LED Display
The DGP-R910 reader includes a tricolour LED display (red, green and amber) that is used to indicate the reader’s status. The LED’s intensity is adjusted through the DGP-ACM11.
The DGP-R910 reader includes a built in beeper with a frequency that is adjusted through the DGP-ACM11.
Weather Resistant
Mount indoors or outdoors.
Error Display
All DGP-R910 readers display communication errors between the reader and the DGP-ACM11 by flashing the amber LED every sec­ond.
Firmware Upgrade
Connect the DNE-CONV2 as shown in Figure 2. Refer to the DNE­CONV2 installation manual for additional information.
Installation Notes
Mounting on Metal
Metal may decrease the read range. The DGP-R910 card reader can be mounted on metal but do not surround it by metal. If the reader must be installed in a metal enclosure, ensure that the face of the card reader is not covered and that there's at least 4cm (1.6") between the card reader and the metal on all sides.
Wiring
See Figure 1 for wiring instructions.
Do not connect more than one DGP-R910 on a single DGP­ACM11.
Figure 2: Firmware Upgrade / Actualización del Firmware / Mise à
niveau du micrologiciel
To computer A una PC Vers l’ordinateur
All jumpers are on. Todos los puentes están ON. Tous les cavaliers sont installés.
To power supply or COMBUS A una fuente de alimentación o al
COMBUS Vers le bloc d’alimentation ou le
COMBUS
1. Red / Rojo / Rouge
2. Black / Negro / Noir
3. Green / Verde / Vert
4. White / Blanco / Blanc
RESIDENTIAL EQUIPMENT CLASS B DIGITAL DEVICE INFORMATION TO USER
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two condi­tions: (1) This device may not cause harmful interference, and (2) This device must accept any inter­ference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for Class B Digital Device, pursu­ant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harm ful inte rf erence to radio or tele­vision reception, which can be deter mined b y turning the e quipm ent of f an d on, t he us er is en courage d to try to correct the interference by one or more of the following measures.
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is con­nected
• Consult the dealer or an experienced radio/TV technician for help
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.