Paradox Security Systems DCT6 Users manual

Open/Close
DCT6
Wireless Door
V1.
Installation Manual
Introduction
The DCT6 is a wireless magnetic door contact that is discreetly hidden within the frame of a door or window.
Installation
Transmitter: Drill a 3/4 in. x 2.75 in. depth (16 mm x 70 mm depth)
hole in the frame and insert the DCT6 transmitter. Secure the
transmitter body A- with two screws or B- with one screw and remove one flange if it interferes with the radial opening or C­press fit installation on narrow frames, see Figure 3, A, B and C.
Magnet: Drill a 3/4 in. x 1.1 in. (19 mm x 28 mm) hole in the frame
to be aligned with the transmitter when door/window is closed and insert the magnet with press fit. Make sure it is aligned with the transmitter and that the gap, when closed, is not greater than
0.4 in. / 10 mm.
A - Two Screws B - One Screw / One Flange
0
Cont
act
Flange removed to allow opening
Breaking the Flange
Open
FIGURE 2 FIGURE 3
Close
1.6. in. / 4 cm
0.8 in. / 2.1
(flange)
cm
2.8 in. /
7.3 cm
Setting RF Frequency / Replacing Battery
1. Open the top of the DCT6 transmitter, turning the cover counter clockwise, see Figure 2.
2. Locate the switch on the PCB, as shown in Figure 4.
3. Slide the switch to the desired frequency 433 MHz or 868 MHz.
4. Remove the battery for a few seconds. Replace the battery back (verify the polarity and insert properly + and - marked on the battery terminals, see Figure 5.
Anti-Tamper Switch
We recommend to replace the battery ever 3 years to avoid leakage.
Selectable
433 MHz / 868
FIGURE
FIGURE
C - Press
RF
MHz
Fit
4
5
1
EVO Programming and Testing
Power
1 x AAA alkaline battery
RF Frequency
Selectable 433/868 MHz on-board
Battery Life
3 years (replace to avoid leakage) Based on 10 openings/closing a day
Wireless Range
MG5000/MG5050/RTX3 - 40m (130 ft) MG6250 - 20m (65 ft)
Wireless range is based on typical indoor installation
Operating Temperature
-20°C to 50°C (-4°F to 122°F)
Anti-tamper Switch
Cover opening
Magnet distance
Up to 0.4 in. / 10 mm
Dimensions
7.3 x 2.1 x 2.1 cm (2.8 x 0.8 x 0.8 in.)
Anti-Tamper
Cover opening
Approvals
CE, EN 50131 Grade 2
Remarks
In-frame installation
Supervision
Live supervision, Battery low
Compatibility
Magellan Panels, MG6250,
1. Enter section [4003]
2. Enter RTX3 or K641LX serial number.
3. Enter section [101] to [132] to assign the DCT6.
4. Open the transmitter as per Figure 2 then close it. This will register the DCT6 entered section.
5. Test signal strength by entering section [601] to [632].
6. Open the transmitter as per Figure 2 then close it.
7. Verify the signal strength on your LCD keypad or TM70/TM50.
MGSP Programming and Testing
1. Enter available section to assign the DCT6 [061] - [092].
2. Open the transmitter as per Figure 2, then close it. This will register the DCT6 to the entered section.
3. Test signal strength by entering correspondent section [101] to [132].
4. Open the transmitter as per Figure 2 then close it.
5. Verify the signal strength on your LCD keypad, TM70/TM50.
Technical Specifications
2
Loading...
+ 1 hidden pages